Remote Alarm Panels Features

December 2007
Remote Alarm Panels
Features
1-1
DFDAP-M / FDAP-M Remote Alarm Panel
Lamp Test Button
NEMA 1 Enclosures
The lamp test button will simultaneously test
all lights, as well as the audible alarm buzzer.
All remote alarm panels come standard with
NEMA 1 enclosures.
Audible Alarm
Standard Alarm Indication
The 24VDC audible alarm will sound when any
alarm condition occurs. It will continue to
sound until either the silence pushbutton is
pressed, or the alarm condition is satisfied.
Audible Alarm “Silence” Pushbutton
Product Description
Eaton’s Cutler-Hammer Remote Alarm Panels
are designed to provide audible and visual
alarms for Electric and Diesel Fire Pump
Controllers.
These remote panels are located at a point of
constant attendance when the pump room is
not constantly supervised.
Product Features
Microprocessor Control
All DFDAP-M and FDAP-M Remote Alarm
Panels are microprocessor based.
The same microprocessor board is used for
both Electric and Diesel units. Indicating lamps
will correspond appropriately. (Refer to the
Standard Alarm Indication information on this
page.)
The Silence pushbutton will silence all active
alarms when pressed, but has no effect on the
associated alarm light(s). If another alarm
condition occurs after the silence button has
been pressed, the alarm buzzer will re-sound
until the button is pressed again, or the alarm
condition is satisfied.
User Selectable Alarm Inputs
Each alarm input (7 total) is user selectable as
either normally open or normally closed by use
of jumpers on the microprocessor board.
Alarm Outputs
Each controller is equipped with seven output
relays. Four are used for alarm lights while the
remaining three are tied directly to the
corresponding alarm inputs.
Electric
Supervisory Power Normal
Pump Operating
Phase Reversal
Phase Failure
Common Alarm
Diesel
Supervisory Power Normal
Engine Running
Engine Trouble
Pump Room Trouble
Controller in OFF Mode
Common Alarm Relay
A common alarm relay will energize under any
alarm condition. Two Form-C output contacts
are provided.
Output Relays
Output relays are PCB style - rated for
8A/250VAC.
Multiple Power Supply Voltages
Both Supervisory (supplied by customer) and
Backup (from the fire pump controller) supply
voltages can be supplied from 110 to 240 Volt,
50-60 HZ.
Standards & Certification
Supervisory - Backup Power Source
“Supervisory Power Normal” Indication
If the Supervisory power source is not
available, the controller will automatically
switch to the Backup source. When
supervisory power is restored, the controller
will switch back to the supervisory source.
The supervisory power normal light will turn ON
when the Supervisory power is available and
will turn OFF when the controller switches to the
backup power source.
The alarm buzzer will sound when the
supervisory power is not available and will
remain ON until the supervisory power is
restored, or the Silence Pushbutton is pressed.
The DFDAP-M / FDAP-M Remote Alarm Panels
meet or exceed the requirements of Underwriters
Laboratories, Underwriters Laboratories Canada,
the Canadian Standards Association, the New York
City building code, and are built to NFPA 20
standards.
N. Y. C.
APPROVED
Technical Data and Specifications
Pending
Line Terminals (Incoming Cables)
Recommended Wire Size
Distance
Number of feet (meters) from the controller to the remote
alarm panel.
Stranded # 16
3000 (914.4)
Stranded # 14
4500 (1371.6)
Stranded # 12
7000 (2133.6)
For more information visit: www.chfire.com
BR05805024K/C
1-2
Remote Alarm Panels
Features
December 2007
FDAP-M Electric Remote Alarm Panel
Dimensions
Standard Enclosure - Type NEMA 1 - Electric Remote Alarm Panel
Approx. Weight
Lbs. (Kg)
40 (18)
NOTES:
1. All enclosures finished in FirePump red.
2. Cable Entrance either top or bottom.
3. Standard Enclosure type NEMA 1.
N. Y. C.
Pending
BR05805024K/C
APPROVED
For more information visit: www.chfire.com
Remote Alarm Panels
Features
December 2007
1-3
DFDAP-M Diesel Engine Remote Alarm Panel
Dimensions
Standard Enclosure - Type NEMA 1 - Diesel Engine Remote Alarm Panel
Approx. Weight
Lbs. (Kg)
40 (18)
NOTES:
1. All enclosures finished in FirePump red.
2. Cable Entrance either top or bottom.
3. Standard Enclosure type NEMA 1.
N. Y. C.
Pending
APPROVED
For more information visit: www.chfire.com
BR05805024K/C
1- 4
Remote Alarm Panels
Features
December 2007
FDAP-M Electric Remote Alarm Panel
Electrical Wiring Schematic
Electric Remote Alarm Panel
N. Y. C.
Pending
BR05805024K/C
APPROVED
For more information visit: www.chfire.com
Remote Alarm Panels
Features
December 2007
1- 5
DFDAP-M Diesel Engine Remote Alarm Panel
Electrical Wiring Schematic
Diesel Remote Alarm Panel
N. Y. C.
Pending
APPROVED
For more information visit: www.chfire.com
BR05805024K/C
1-6
Remote Alarm Panels
Features
December 2007
DFDAP-M / FDAP-M Electric Local Alarm Panel
Catalog Number Selection
DFDAP-M / FDAP-M Remote Alarm Panel Catalog Numbering System
Catalog Number Selection Chart - DFDAP-M / FDAP-M
Catalog Number
Voltage
DFDAP-M
FDAP-M
120-240V, 50/60Hz
Price
$600
$600
Product Selection
DFDAP-M / FDAP-M Remote Alarm Panel Catalog Numbering System
Options
Model
DFDAP-M = Diesel
FDAP-M = Electric
A1
A2
A3
A6
C1
C4
C5
C6
C7
C8
E2
E5
G1
G2
-
Control Power Loss Indicating Light
Remote Start Pushbutton
Audible and Visual Auxiliary Alarm
Remote Pilot Light - Common Alarm (Diesel)
Extra Contacts "Pump Run"
Remote Contacts - Low Reservoir
Remote Contacts - High Reservoir
Audible & Visible Alarm - Low Fuel
Audible & Visible Alarm - High Fuel
Audible & Visible Alarm - Fuel Spill
Nema 4- Watertight Enclosure
Nema 4X - Stainless Steel Enclosure
120V Single Phase
240V Single Phase
Product Selection
Options
Designation
Description
A1
A2
A3
A6
C1
C4
C5
C6
C7
C8
E2
E5
G1
G2
Control Power Loss Indicating Light
Remote Start Pushbutton
Audible and Visual Auxiliary Alarm
Remote - Common Alarm (Diesel)
Extra Contacts "Pump Run"
Remote Contacts - Low Reservoir
Remote Contacts - High Reservoir
Audible & Visible Alarm - Low Fuel
Audible & Visible Alarm - High Fuel
Audible & Visible Alarm - Fuel Spill
NEMA 4 - Watertight Enclosure
NEMA 4X - Stainless Steel Enclosure
120V Single Phase
240V Single Phase
BR05805024K/C
Price
For more information visit: www.chfire.com
$90
$90
$120
$120
$160
$120
$120
$120
$120
$120
$795
$975
Std
Std
December 2007
Remote Alarm Panels
Features
1- 7
DFDAP-M / FDAP-M Remote Alarm Panel
For more information visit: www.chfire.com
BR05805024K/C
FIRE PUMP CONTROLLERS
December 2007
Fire Pump Controller Family
FD20
Limited Service Controller
FD30
FT SERIES
Transfer Switches
FD100 / 110
Across-the-Line
Diesel Engine
Controllers
FD40
FDM
Part Winding
Medium Voltage
Controllers
FD50
FDF
Primary Resistor
Foam Pump
Controllers
FD60
FDV
Autotransformer
Variable Speed
Controllers
FD70
FDR
WYE DELTA (Star-Delta)
Open Transition
Residential
Controllers
FD80
FDJP / JY
WYE DELTA (Star-Delta)
Closed Transition
Jockey Pump
Controllers
FD90
Soft Start
FDAP-M
Remote Alarm
Panels
For more information on Eaton Cutler-Hammer Fire Pump Controllers, email us at chcfirepump@eaton.com or call us at 1-877-860-7955.
EATON
Cutler-Hammer
2256 - 29th Street NE #10
Calgary, Alberta, T1Y 7G4
Canada
tel: 403-717-2000
fax: 403-717-0567
www.chfire.com
© 2007 Eaton Corporation
All Rights Reserved
Printed in Canada
Publication No.: BR05805024K/C
December 2007