December 2007 Remote Alarm Panels Features 1-1 DFDAP-M / FDAP-M Remote Alarm Panel Lamp Test Button NEMA 1 Enclosures The lamp test button will simultaneously test all lights, as well as the audible alarm buzzer. All remote alarm panels come standard with NEMA 1 enclosures. Audible Alarm Standard Alarm Indication The 24VDC audible alarm will sound when any alarm condition occurs. It will continue to sound until either the silence pushbutton is pressed, or the alarm condition is satisfied. Audible Alarm “Silence” Pushbutton Product Description Eaton’s Cutler-Hammer Remote Alarm Panels are designed to provide audible and visual alarms for Electric and Diesel Fire Pump Controllers. These remote panels are located at a point of constant attendance when the pump room is not constantly supervised. Product Features Microprocessor Control All DFDAP-M and FDAP-M Remote Alarm Panels are microprocessor based. The same microprocessor board is used for both Electric and Diesel units. Indicating lamps will correspond appropriately. (Refer to the Standard Alarm Indication information on this page.) The Silence pushbutton will silence all active alarms when pressed, but has no effect on the associated alarm light(s). If another alarm condition occurs after the silence button has been pressed, the alarm buzzer will re-sound until the button is pressed again, or the alarm condition is satisfied. User Selectable Alarm Inputs Each alarm input (7 total) is user selectable as either normally open or normally closed by use of jumpers on the microprocessor board. Alarm Outputs Each controller is equipped with seven output relays. Four are used for alarm lights while the remaining three are tied directly to the corresponding alarm inputs. Electric Supervisory Power Normal Pump Operating Phase Reversal Phase Failure Common Alarm Diesel Supervisory Power Normal Engine Running Engine Trouble Pump Room Trouble Controller in OFF Mode Common Alarm Relay A common alarm relay will energize under any alarm condition. Two Form-C output contacts are provided. Output Relays Output relays are PCB style - rated for 8A/250VAC. Multiple Power Supply Voltages Both Supervisory (supplied by customer) and Backup (from the fire pump controller) supply voltages can be supplied from 110 to 240 Volt, 50-60 HZ. Standards & Certification Supervisory - Backup Power Source “Supervisory Power Normal” Indication If the Supervisory power source is not available, the controller will automatically switch to the Backup source. When supervisory power is restored, the controller will switch back to the supervisory source. The supervisory power normal light will turn ON when the Supervisory power is available and will turn OFF when the controller switches to the backup power source. The alarm buzzer will sound when the supervisory power is not available and will remain ON until the supervisory power is restored, or the Silence Pushbutton is pressed. The DFDAP-M / FDAP-M Remote Alarm Panels meet or exceed the requirements of Underwriters Laboratories, Underwriters Laboratories Canada, the Canadian Standards Association, the New York City building code, and are built to NFPA 20 standards. N. Y. C. APPROVED Technical Data and Specifications Pending Line Terminals (Incoming Cables) Recommended Wire Size Distance Number of feet (meters) from the controller to the remote alarm panel. Stranded # 16 3000 (914.4) Stranded # 14 4500 (1371.6) Stranded # 12 7000 (2133.6) For more information visit: www.chfire.com BR05805024K/C 1-2 Remote Alarm Panels Features December 2007 FDAP-M Electric Remote Alarm Panel Dimensions Standard Enclosure - Type NEMA 1 - Electric Remote Alarm Panel Approx. Weight Lbs. (Kg) 40 (18) NOTES: 1. All enclosures finished in FirePump red. 2. Cable Entrance either top or bottom. 3. Standard Enclosure type NEMA 1. N. Y. C. Pending BR05805024K/C APPROVED For more information visit: www.chfire.com Remote Alarm Panels Features December 2007 1-3 DFDAP-M Diesel Engine Remote Alarm Panel Dimensions Standard Enclosure - Type NEMA 1 - Diesel Engine Remote Alarm Panel Approx. Weight Lbs. (Kg) 40 (18) NOTES: 1. All enclosures finished in FirePump red. 2. Cable Entrance either top or bottom. 3. Standard Enclosure type NEMA 1. N. Y. C. Pending APPROVED For more information visit: www.chfire.com BR05805024K/C 1- 4 Remote Alarm Panels Features December 2007 FDAP-M Electric Remote Alarm Panel Electrical Wiring Schematic Electric Remote Alarm Panel N. Y. C. Pending BR05805024K/C APPROVED For more information visit: www.chfire.com Remote Alarm Panels Features December 2007 1- 5 DFDAP-M Diesel Engine Remote Alarm Panel Electrical Wiring Schematic Diesel Remote Alarm Panel N. Y. C. Pending APPROVED For more information visit: www.chfire.com BR05805024K/C 1-6 Remote Alarm Panels Features December 2007 DFDAP-M / FDAP-M Electric Local Alarm Panel Catalog Number Selection DFDAP-M / FDAP-M Remote Alarm Panel Catalog Numbering System Catalog Number Selection Chart - DFDAP-M / FDAP-M Catalog Number Voltage DFDAP-M FDAP-M 120-240V, 50/60Hz Price $600 $600 Product Selection DFDAP-M / FDAP-M Remote Alarm Panel Catalog Numbering System Options Model DFDAP-M = Diesel FDAP-M = Electric A1 A2 A3 A6 C1 C4 C5 C6 C7 C8 E2 E5 G1 G2 - Control Power Loss Indicating Light Remote Start Pushbutton Audible and Visual Auxiliary Alarm Remote Pilot Light - Common Alarm (Diesel) Extra Contacts "Pump Run" Remote Contacts - Low Reservoir Remote Contacts - High Reservoir Audible & Visible Alarm - Low Fuel Audible & Visible Alarm - High Fuel Audible & Visible Alarm - Fuel Spill Nema 4- Watertight Enclosure Nema 4X - Stainless Steel Enclosure 120V Single Phase 240V Single Phase Product Selection Options Designation Description A1 A2 A3 A6 C1 C4 C5 C6 C7 C8 E2 E5 G1 G2 Control Power Loss Indicating Light Remote Start Pushbutton Audible and Visual Auxiliary Alarm Remote - Common Alarm (Diesel) Extra Contacts "Pump Run" Remote Contacts - Low Reservoir Remote Contacts - High Reservoir Audible & Visible Alarm - Low Fuel Audible & Visible Alarm - High Fuel Audible & Visible Alarm - Fuel Spill NEMA 4 - Watertight Enclosure NEMA 4X - Stainless Steel Enclosure 120V Single Phase 240V Single Phase BR05805024K/C Price For more information visit: www.chfire.com $90 $90 $120 $120 $160 $120 $120 $120 $120 $120 $795 $975 Std Std December 2007 Remote Alarm Panels Features 1- 7 DFDAP-M / FDAP-M Remote Alarm Panel For more information visit: www.chfire.com BR05805024K/C FIRE PUMP CONTROLLERS December 2007 Fire Pump Controller Family FD20 Limited Service Controller FD30 FT SERIES Transfer Switches FD100 / 110 Across-the-Line Diesel Engine Controllers FD40 FDM Part Winding Medium Voltage Controllers FD50 FDF Primary Resistor Foam Pump Controllers FD60 FDV Autotransformer Variable Speed Controllers FD70 FDR WYE DELTA (Star-Delta) Open Transition Residential Controllers FD80 FDJP / JY WYE DELTA (Star-Delta) Closed Transition Jockey Pump Controllers FD90 Soft Start FDAP-M Remote Alarm Panels For more information on Eaton Cutler-Hammer Fire Pump Controllers, email us at chcfirepump@eaton.com or call us at 1-877-860-7955. EATON Cutler-Hammer 2256 - 29th Street NE #10 Calgary, Alberta, T1Y 7G4 Canada tel: 403-717-2000 fax: 403-717-0567 www.chfire.com © 2007 Eaton Corporation All Rights Reserved Printed in Canada Publication No.: BR05805024K/C December 2007