Energy Conservation Code Commercial Mechanical CHAPTER 5 WORKSHEET 1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is ____________. a. b. c. d. 2. The NC specific COMcheck software may be used to demonstrate compliance for all of the following except ____________. a. b. c. d. 3. 2012 North Carolina Energy Conservation Code 2006 IECC 2009 IECC 2012 IECC office building public school three story apartment building four story apartment building The following are compliance path options for commercial buildings except _____________. a. b. c. d. 4. Chapter 5 contains requirements for all the following except __________. a. b. c. d. 5. meet chapter 5 mandatory and prescriptive provisions meet NC Comcheck meet Section 507 “Total Building Performance” meet 2004 ASHRAE 90.1 plus 20% improvement industrial process systems and equipment HVAC systems for building space conditioning lighting controls service water heating Using Table 503.2.3(1), the minimum efficiency allowed for an electrically operated 120,000 Btu/h split system air cooled air conditioner is ___________. a. b. c. d. 13.0 SEER 11.2 SEER 11.0 EER 10.0 EER 2012 Energy Conservation Code Page 1 of 10 Revised: 2/28/2013 6. Using Table 503.2.3(4), the minimum efficiency allowed for a gas fired warm air furnace of 200,000 Btu/h input is ___________. a. b. c. d. 7. The supply of heating and cooling energy to each building zone shall be controlled by an individual _____________. a. b. c. d. 8. 78% AFUE 82% AFUE 90% AFUE 100% AFUE humidistat occupancy sensor economizer thermostat Exceptions from the requirements of automatic off-hour control of thermostats for zones of HVAC systems include all the following except __________. a. zones that will be operated continuously b. zones with a full load demand exceeding 6,800 Btu/h supplied from a VAV system c. zones cooled by a packaged terminal air conditioners d. zones heated and cooled by a packaged terminal heat pumps 9. For which case below would a required shut-off damper not be allowed to be a gravity damper? a. b. c. d. 10. Ducted outside air intake of 300 cfm Ducted exhaust of 400 cfm in a three story building Ducted outside air intake of 500cfm in a three story building Ducted exhaust of 200cfm Given that an exception is not applicable, ventilation systems in commercial buildings exceeding __________ square feet shall have demand controlled ventilation. a. b. c. d. 2,000 2,500 5,000 10,000 2012 Energy Conservation Code Page 2 of 10 Revised: 2/28/2013 11. Demand control ventilation systems in commercial buildings shall be capable of reducing outside air supply to at least ____________ per cent below design ventilation rates. a. b. c. d. 12. Given that an exception is not applicable, in all commercial buildings, spaces larger than __________ square feet with a maximum occupant load of 40 or more people per 1,000 square feet of floor area shall include ventilation system demand control of those spaces. a. b. c. d. 13. 25% 50% 75% 85% In commercial buildings, heating and cooling system supply and return ducts located in unconditioned space shall be insulated with a minimum of ___________ insulation. a. b. c. d. 15. 250 500 1000 10,000 Given that an exception is not applicable, an energy recovery system is required for commercial building ventilation systems that have both a design supply air capacity of 5,000 cfm or greater and a minimum outside air supply of _____________ or greater of the design supply air quantity. a. b. c. d. 14. 25% 50% 70% 100% R-4 R-5 R-8 R-12 In commercial buildings, heating and cooling system supply and return ducts located outdoors shall be insulated with a minimum of ___________ insulation. a. b. c. d. R-4 R-5 R-8 R-12 2012 Energy Conservation Code Page 3 of 10 Revised: 2/28/2013 16. In commercial buildings, heating and cooling system supply and return ducts located within a commercial building exterior wall that separates conditioned space from the outdoors shall be separated from the building exterior by a minimum of ____________ insulation. a. b. c. d. 17. In commercial buildings, heating and cooling system exhaust ducts located in conditioned space shall be insulated with a minimum of ____________ insulation or as otherwise required to prevent condensation formation on the duct exterior. a. b. c. d. 18. R-0 R-4 R-5 R-8 In commercial buildings, the low-pressure heating and cooling ducts located in the following locations must be sealed except those located in __________. a. b. c. d. 20. R-0 R-4 R-5 R-8 In commercial buildings, heating and cooling system supply ducts located within a return air plenum shall be insulated with a minimum of __________ or as otherwise required to prevent condensation formation on the duct exterior. a. b. c. d. 19. R-5 R-8 R-13 R-15 ventilated attics unconditioned spaces the conditioned spaces they serve ventilated crawl spaces In commercial buildings, high pressure duct systems designed to operate in excess of 3 inches w.g. static pressure design pressure shall be leak-tested over representative sections totaling at least ____________ of the duct area. a. b. c. d. 25% 50% 75% 100% 2012 Energy Conservation Code Page 4 of 10 Revised: 2/28/2013 21. Given that the designed chilled water temperature is 450 F, the required minimum piping insulation thickness for 2 inch nominal pipe diameter chilled water piping serving a chilled water plant for a building HVAC system is ___________. a. b. c. d. 22. Given that an exception is not applicable, test and balance activities for commercial building HVAC systems shall include _____________. a. b. c. d. 23. building owner contractor inspector NC licensed design professional Heating systems installed to provide comfort heating outside a commercial building shall be ____________ systems and require special controls to shut off the system when no occupants are present. a. b. c. d. 25. air system balancing only hydronic system balancing only both air system balancing and hydronic system balancing neither air system balancing nor hydronic system balancing Given that a NC licensed design professional’s seal is required for a commercial building project, the required “Statement of Compliance – HVAC System Installation” document required to be submitted shall be prepared and signed by the ____________. a. b. c. d. 24. no requirement 1 ½ inches 2 inches 3 inches convective radiant conductive None allowed Given that an exception does not apply for a commercial building HVAC system, supply air economizers shall be provided on each cooling system greater than or equal to 65,000 Btu/h when the building is located in _____________. a. b. c. d. Zone 3A only Zone 4A only Zones 4A and 5A only Zones 3A, 4A, and 5A 2012 Energy Conservation Code Page 5 of 10 Revised: 2/28/2013 26. Supply air economizers, when required for commercial building HVAC systems, shall be capable of providing ___________ outdoor air. a. b. c. d. 27. Individual VAV fans with motors of ___________ or greater shall be driven by a mechanical or electrical variable speed drive or shall be equipped with other energy conserving controls as prescribed by the code. a. b. c. d. 28. 200,000 Btu/h 300,000 Btu/h 400,000 Btu/h 500,000 Btu/h For commercial buildings, hydronic heating systems greater than or equal to ______________ output capacity supplying heated water to comfort conditioning systems shall include part load controls having the capability to automatically reset supply hot water temperature or reduce system pump flow by at least 50% of the design flow rate. a. b. c. d. 30. 5 horsepower 10 horsepower 20 horsepower 25 horsepower Hydronic heating systems for commercial buildings comprised of a single boiler and greater than _____________ input design capacity shall include either a multistaged or modulating burner. a. b. c. d. 29. 25% 50% 75% 100% 200,000 Btu/h 300,000 Btu/h 500,000 Btu/h 1,000,000 Btu/h For commercial buildings, generally, supply air systems serving multiple zones must be VAV systems and be provided with controls to reduce primary air supply to each space to a minimum before allowing any of the following to occur except for ___________. a. b. c. d. reheating recooling recirculation mixing 2012 Energy Conservation Code Page 6 of 10 Revised: 2/28/2013 31. For commercial buildings, multiple zone HVAC systems shall include controls that are capable of automatically resetting the supply air temperature to at least ___________ of the difference between the design air supply temperature and the design room temperature in response to representative building loads or outdoor air temperature. a. b. c. d. 32. 25% 50% 75% 100% Which of the following is an example of a “complex” HVAC system? a. Two pipe heating system serving two zones with no cooling system installed b. Packaged terminal heat pump system of 24,000 BTU/h input capacity serving a single zone c. HVAC system with VAV units for multiple zones d. Gas fired warm air heating furnace system of 200,000 Btu/h input capacity serving a single zone 33. A new commercial building must also comply with one of the “Additional Prescriptive Compliance Requirements” listed in Section 506. Which of the following is not one of the “Additional Prescriptive Compliance Requirements” listed? a. b. c. d. 34. Increased insulation More efficient mechanical equipment Reduced lighting power density Automatic daylighting control system For a commercial building, the “Section 507 Total Building Performance” compares the ___________ energy cost of the proposed design to that of the standard reference design. a. b. c. d. 2012 Energy Conservation Code daily monthly annual lifetime Page 7 of 10 Revised: 2/28/2013 35. When the “Section 507 Total Building Performance” compliance approach is selected as the path to compliance for a commercial building, in addition to the required energy cost analysis, all of the following compliance documentation shall be provided to the inspector except ______________. a. b. c. d. address of the residence an inspection checklist life cycle cost analysis name and version of the software 2012 Energy Conservation Code Page 8 of 10 Revised: 2/28/2013 Energy Conservation Code CHAPTER 5 Commercial Mechanical ANSWER KEY Number Answer Section 1. a EC501.1 2. c EC501.1 3. d EC501.1 4. a EC501.2 5. b EC503.2.3 Table 503.2.3(1) 6. a EC503.2.3 Table 503.2.3(4) 7. d EC503.2.4.1 8. b EC503.2.4.3 9. b EC503.2.4.4 10. d EC503.2.5.1 11. b EC503.2.5.1 12. b EC503.2.5.1 13. c EC503.2.6 14. b EC503.2.7 15. c EC503.2.7 16. b EC503.2.7 17. a EC503.2.7 18. a EC503.2.7 19. c EC503.2.7.1.1 Exception 2 2012 Energy Conservation Code Page 9 of 10 Revised: 2/28/2013 20. a EC503.2.7.1.3 21. b EC503.2.8 Table 503.2.8 22. c EC503.2.9.1, EC503.2.9.1.1, EC503.2.9.1.2 23. d EC503.2.9.3 & Appendix 5 24. b EC503.2.11 25. d EC503.3.1 Table 503.3.1(1) 26. d EC503.3.1 27. b EC503.4.2 28. d EC503.4.3 29. b EC503.4.3.4 30. c EC504.3.5 31. a EC503.4.5.4 32. c EC503.3, EC503.4.5 33. a EC506.1 34. c EC507.3 35. c EC507.4.1 2012 Energy Conservation Code Page 10 of 10 Revised: 2/28/2013