FIXTURE DEFINITIONS (INDIVIDUALS/ROWS/PATTERNS): CRN TO BE USED IN CONJUNCTION WITH FIXTURE DETAIL AND LAYOUT SHEETS STEP 1: INSTALL FIXTURE STEP 2: PREPARE ACCESS COVER L.END 1 SPLICE PAT BALLAST CHANNEL (EXPOSED BY CUTOUT IN HOUSING) SPLICE FIXTURE FLANGE PAT_L WS) (RO NDS) . P TY . (I /4" 4" TYP 1 3 3/ END SHELL EACH RECESSED UNIT IS FABRICATED WITH (4) 3/16" DIA. HOLES (2 PER HANGER BRACKET) FOR ATTACHMENT OF HOUSING TO ABOVE STRUCTURE BY (BY OTHERS). 1. REMOVE K.O. IN ACCESS COVER 1 (SUPPLIED). WIRE 1. RAISE FIXTURE & SECURE TO ABOVE STRUCTURE BY WIRE (BY OTHERS). 2. SECURE GREENFIELD CONNECTOR (BY OTHERS) TO ACCESS COVER. STEP 5: CEILING INSTALLATION R.END IND CRN = 2-WAY CORNER IND = INDIVIDUAL FIXTURE INT = INTERMEDIATE FIXTURE INT_P = INTERMEDIATE PATTERN FIXTURE L.END = LEFT END FIXTURE (TYPICAL FEED) L.END_P = LEFT END PATTERN FIXTURE (TYPICAL FEED) PAT = PATTERN FIXTURE PAT_L = PATTERN LEFT FIXTURE R.END = RIGHT END FIXTURE R.END_P = RIGHT END PATTERN FIXTURE INT_P BOTTOM FLANGE DETAIL "A" - STRIPE SPLICE INSERTION PREVIOUSLY INSTALLED FIXTURE (PLAN VIEW) SEE JOB LAYOUT FOR ROW PLACEMENT CRN 2 GREENFIELD CONNECTOR (BY OTHERS) CRN INT INT HANGER BRACKET L.END_P SPLICE STEP 3: INSTALL COVER STEP 4: JOINING (ROWS/PATTERNS) DETAIL "B" - FIXTURE JOINING GROOVE JOINING FIXTURE R.END_P INSTALLATION SHEET FOR STRIPE 31/32 (STRP31/32) RECESSED FLANGELESS FIXTURE SPLICE (SEE FIXT. DEFINITIONS FOR PLAN VIEW) 3 HANGER/ JOINER BRACKET CRN 1. RAISE FIXTURE & MAKE APPROPRIATE ELECTRICAL CONNECTIONS AT JOINING SECTION. 2-WAY CORNER 1. MAKE ALL NECESSARY ELECTRICAL CONNECTIONS. 2. ATTACH ASSEMBLED ACCESS COVER 1 TO BALLAST CHANNEL BY SLIDING BOTTOM FLANGE OF COVER UNDER TOP OF CHANNEL & TOWARDS END SHELL. 3. SECURE ACCESS COVER 1 WITH 8-32 X 3/8" SELF-TAPPING SCREWS 2 (1 PER COVER). CRN STEP 6: DIFFUSER INSTALLATION DRYWALL SCREW (BY OTHERS) NOTE: JOIN FIXTURES SO THAT (2) SPLICES FROM PREVIOUSLY INSTALLED FIXTURE SLIDE IN GROOVES OF JOINING FIXTURE AS SHOWN IN DETAIL "A" ABOVE. NOTE STRP31 : HOUSING USED 2. MATE JOINING BRACKETS AS SHOWN, & SECURE WITH (6) 8-32 X 3/8" MACHINE SCREWS 3 (SUPPLIED) & (6) 8-32 KEPS NUTS 4 (SUPPLIED) AT MATING HOLES (REFER TO DETAIL "B" ABOVE). FOR ILLUSTRATION PURPOSES. STRP32 INSTALLATION IS SIMILAR. BALLAST ACCESS BALLASTS STRP32 3. SECURE BRACKETS WITH WIRE (BY OTHERS) TO ABOVE STRUCTURE. FIG. 1-B ITEM 1 2 3 4 5 HOOK STRP31 2 2 1 1/2" APPROX. 3" APERTURE 3 15/32" HOUSING O.D. 3 5/8" ROUGH-IN* 5/8" DRYWALL (BY OTHERS) FIBERGLASS DRYWALL TAPE WITH PLASTER SKIMCOAT (BY OTHERS) DRYWALL SCREWS 1" LENGTH MIN. (BY OTHERS) JOINT COMPOUND/MUD AND FEATHER (BY OTHERS) 1 1 2 NOTE: FIXTURE TO BE INSTALLED BEFORE DRYWALL. HOLD APERTURE DIM 3" WHEN INSTALLING DRYWALL 1. FOR ACCESS TO BALLAST(S), REMOVE LENS 5 (SEE STEP 6). USE FLATHEAD SCREWDRIVER TO PRY LENS OUT OF HOUSING. 2 REMOVE REFLECTORS BY PUSHING REFLECTORS UP SO THAT TABS ARE RELEASED FROM HOUSING NOTCHES, THEN PULL DOWN ON REFLECTOR. NOTE: THERE ARE (3) TABS PER 3'-5' REFLECTOR & (4) TABS PER 6'-8' REFLECTOR. USE INDICATING HOLES TO LOCATE TABS. 3. REMOVE BALLAST CHANNEL COVER BY UNSCREWING (2) 8-32 X 3/8" SELF-TAPPING SCREWS 2 FOR ACCESS TO BALLAST(S) (SEE FIG. 1-B RIGHT). HOUSING FLANGE HOUSING FLANGE 5 * INSTALL SHEETROCK WITH THIS TOLERANCE - AFTER FIXTURE IS INSTALLED - TO AVOID BOWING FIXTURE SIDES. AFTER INSTALLATION, UNIT IS TO BE AS SHOWN ABOVE, WITH ONLY THE BOTTOM OF THE FIXTURE VISIBLE. RECOMMENDED SHEETROCK THICKNESS IS 5/8" WITH ROUGH-IN WIDTH OF 3 5/8".* DRYWALL SCREWS (BY OTHERS) ARE TO ATTACH THE DRYWALL TO FIXTURE FLANGES. FIXTURE FLANGE STARTS 3 1/4" FROM EITHER END OF FIXTURE FOR UNITS MOUNTED IN ROWS & 3/4" FROM EITHER END OF FIXTURE FOR INDIVIDUALS, AS SHOWN IN STEP 1. PLASTER (BY OTHERS) TO COAT SHEETROCK. 2 FIG. 1-A HOUSING 5 5 COVER NOTE: END SHELL NOT SHOWN HERE FOR ILLUSTRATION PURPOSES. DRYWALL (BY OTHERS) HOOK REFLECTOR NOTCH REFLECTOR 2. RAISE OTHER EDGE OF LENS UP INTO FIXTURE UNTIL EDGE OF LENS CLEARS HOUSING FLANGE & "SNAPS" ABOVE HOUSING FLANGE. NOTE: HEIGHT THAT LENS "SNAPS" INTO PLACE IN FIXTURE VARIES DEPENDING ON WHETHER HOUSING IS STRP31 OR STRP32 (SEE ABOVE). LINEAR LIGHTING RESERVES THE RIGHT TO MAKE ANY MECHANICAL CHANGES TO THE FIXTURE WHICH DO NOT AFFECT THE OVERALL APPEARANCE OR PERFORMANCE. NOTE: CEILING AND WALLS TO BE ADEQUATELY REINFORCED TO SUPPORT FIXTURE WEIGHT. LINEAR LIGHTING IS NOT RESPONSIBLE FOR IMPROPER REINFORCEMENT. DESCRIPTION WIRING ACCESS COVER SCREW 8-32x3/8" SELF-TAPPING SCREW 8-32x3/8" PAN HEAD MACHINE NUT, 8-32 KEPS SANDBLASTED LENS (SBL) ARCHITECT: ENGINEER: LIGHTING DESIGNER: CONTRACTOR: DISTRIBUTOR: PROJECT: <> LINEAR LIGHTING INDICATING HOLE TAB PULL DOWN ON REFLECTOR SO THAT REFLECTOR NOTCHES ARE RELEASED FROM HOOKS IN HOUSING. 284577 630001 630011 630017 450692 SHEET, STRIPE 31/32 TITLE: INSTALLATION (STRP31/STRP32) RECESSED FLANGELESS FIXTURE TYPE: 31-30 HUNTERS POINT AVE. LONG ISLAND CITY, N. Y. 11101 TEL:(718)361-7552 FAX:(718)937-2747 HOUSING NOTCH 1. RAISE EDGE OF LENS 5 OVER HOUSING FLANGE AS SHOWN. LINEAR P/N FOR FIXTURE DETAIL SEE SHEET(S):<> FOR LAYOUT & SCHEDULE SEE SHEET(S):<> 3 REFLECTOR FIXTURE FLANGES 4 ASSEMBLY DRAWING NO: D0117622 DATE REV DESCRIPTION BY REVISIONS THIS PRINT IS THE PROPERTY OF LINEAR LIGHTING CORP., AND THE INFORMATION IT CONTAINS MAY NOT BE USED WITHOUT THE WRITTEN CONSENT OF LINEAR LIGHTING. DRAWN BY: DATE: PROJECT DRAWING NO: SHEET OF REV.