MV Air Insulated Metal Enclosed Switchgears

advertisement
MV Air Insulated
Metal Enclosed
Switchgears
Rated Voltage
: 12 kV - 36 kV
Rated Current
: 400 A - 1250 A
Short Circuit Current : 16 kA - 25 kA
Standard IEC 62271-200
Nature is
Our Most
Valuable Partner
MV Air Insulated
Metal Enclosed
Switchgears
Elimsan was founded in 1980 in Adapazarı TURKEY
for manufacturing electrical switchgears and switching
devices.
ELIMSAN is a specialist company in the electrical
switchgears production for the range 7,2 kV – 525 kV.
We have a very big capacity for the production of SF6
Gas and Vacuum Circuit Breakers (10000 pcs./year),
Metal Enclosed Switchgears (3000 panels/year), Metal
Clad Switchgears (1500 panels / year), High VoltageDisconnectors (3000 units / year).
Some of other main products are; MV-HV CTs, VTs, Fuses, and Lighting Fixtures. All of
ourproducts have type test reports from CESI (Italy), KEMA (Holland), IPH (Germany) and ICMET (Romania).
By developing its own technology
considering quality importance, Elimsan became one of
the major manufacturing companies in the world which satisfies all requirements needed for electric
transmission and distribution systems. Since last 29 years, more than 100.000 units of these equipments had been
manufactured and distributed over allTurkey and world.They are all under operation satisfactorily since their assembly
Elimsan has a very large land more than 550.000 sqm and 50.000 sqm closed facilities. All of our
equipments are manufactured with CNC controlled workbenches under the ISO 9001 Quality Management
System and ISO 14001 Environmental Management System. Our products are tested in our accredited High Voltage
Laboratories according to ISO 17025 standards.
Since the establishment date, Elimsan always produces advanced technology along the Turkey’sdevelopment
process; represents our country successfully, challenges in competitive international market conditions. Its
products are preferred on wide geographical areas from Australia to Estonia, from Far East to South America.
In the year of 2008 Elimsan has signed a partnership agreement with Saudi Cable which is on of the
well-established firms in the world. After this partnership, Elimsan reinforced its place in the global market.
Elimsan is a creative, innovated and dynamic company. We respect and pay much attention to
communicate and interact with our clients; and meeting each customer’s needs is our number one priority.
3
MV Air Insulated Metal Enclosed Switchgears
Brief History Of Company; Elimsan
MV Air Insulated Metal Enclosed Switchgears
INTRODUCTION
Elimsan TG21-XX designation covers medium voltage cubicles or prefabricated systems with SF6 or vacuum
arc quenching medium. These switchgears are defined by IEC 62271-200 Standard. This leaflet covers the
switchgears TG21-XX type suitable for:
•
•
•
•
•
Small substations for private users
MV- LV public distribution substations
Medium voltage metering substations
Network substations and industrial applications
Motor control centers with vacuum contactors
These switchgears permit carry out all the functions that could be presented, so much in the networks of
electrical energy distribution and transformer centers.
•
•
•
•
Operations of development, such as to break in no-load of the ring networks or radial networks.
Disconnecting with earthing of the active parts, to effect periodic maintenance.
Protection of power transformers for overloads and short circuits.
Troubleshooting in cables and monitoring the phases conformity before making of cloosed- loops.
STANDARTS
The switchgears have been developed and tested according to the following procedures:
•
•
•
•
•
IEC 62271-200. A.C. Metal-Enclosed Switchgear and Controlgear
IEC 62271-100. High-voltage circuit breakers
IEC 60265-1. High-voltage switches
IEC 60420. High-voltage alternating current switch-fuse combinations.
IEC 62271-102. High-voltage disconnector and earthing switchs.
PROTECTION DEGREE
•
•
•
•
•
Load Break Switch
Busbar Compartment
Between Compartment
Mechanisms
Cable Compartment
: IP68
: IP3X
: IP3X
: IP3X
: IP3X
Switchgear in service:
Being in service with the switch closed, to access to the interior of the switchgear, it’s necessary to accomplish
the following operations:
• Open the switch.
• Verify the absence of tension in the cables by means of the neon lamps of voltage indicators.
• Close the earthing-switch.
• Open the door.
Switchgear out of service:
To open the door previously earthing switch must be closed. In this position:
• The switch can not be closed.
• The earthing switch can not be opened.
4
MV Air Insulated Metal Enclosed Switchgears
EXAMPLE 1
Distribution feeder with measuring and protection
Exist a double interlock:
•
•
Among the Load Break Switch and the earthing switch
Among the Load Break Switch, the earthing switch and the door.
To accomplish the measure in cables will can be get, by a wiling action, realising the interlocks using an
equipment that is supplied in ali cabins and it’s fixed inside the door.
This equipment prevents closing of the door and, before closing it have to be removed, remaining the
interlocks in its initial position.
To prevent that someone could operate the switchgear, while are effected the measurements in the cables,
exits a safety device that prevents the introduction of the operating lever.
Limited overall dimensions:
The switchboards can be installed in small rooms and be leaned against the wall. All the operations are carried
out at the front of the switchboard.
Service continuity:
The segregations of the various compartments allow to operate when switchboard alive to re-place
components such as fuses, relays, cable terminals, etc.
Safety:
Suitables
mechanical
and
key
locks,
guarantee
the
safety
of
personel,
preventing from any possibility of wrong operations. The metal segregations between the busbar compartment and the instruments compartment, prevents accidental contacts with medium
voltage components. The switchboard is provided with grounding of the whole structure and components.
Inspection and maintenance:
Inspection of the equipment is facilitated by porthole placed on the unit door and the maintenance is simple by
the easy access to equipment with open door.
Construction characteristics and painting:
The structural steelwork is made of bent and bolted sheet plate, painting with electrostatic powder colour
RAL7032.
5
MV Air Insulated Metal Enclosed Switchgears
BUSBAR COMPARTMENT
The busbar insulating supports are integral with the switchgear (switch or disconnector)
The busbars consist of:
• Aluminium or copper bar for 400A and 630A
• Copper bar for 1250A, protected by an insulating sheath and flattened at both ends for
conventional crew/spring washer attachment. The connection screw is covered by a stress cap.
The front access is elosed by a bolted plate with a yellow warning plate.
EXAMPLE 2
Customer Measurement and
Transformer Protection System
EXAMPLE 3
Distrubution Center
INSTRUMENT COMPARTMENT
•
•
•
Load Break Switch cubicles and off-load disconnector cubicles: The lower part of the switch and of the
disconnector is fitted with functional lugs for mounting dry cables with standardized bimetal heavily crimped
clips.
Transformer protection cubicles: Connection is made at the fuse lower supports.
Circuit Breaker cubicles: connection is made on a support lug mounted on the capacitor dividers.
The reduced depth of the cubicles results in the last phase being within arm reach, and this greatly facilitates
cable installation.
For easier work, a stud enables the operator to hook up the cable end clip during the connection operation.
EARTHING SWITCHES
•
In generally Elimsan switchboards have two simultaneously operated earthing switches. The station earth
bar is situated on the cubicle top. The station is connected to earth by means of a contact stud on the
forward part of the side partition.
FUSE COMPARTMENT
The lower part of cubicles houses standardized for fuses. During fuses changing the operator’s safety is
ensured by two earthing switches.
Capacitor bank protection:
Use fuses with a rated current immediately superior to. 1.6 or 1.8 times the capacitor bank rated current.
6
MV Air Insulated Metal Enclosed Switchgears
Motor protection:
Within the limit of 3 starting per hour, each of a duration
of 10 seconds and with Id/ln < 6 (Id = starting current and
In = motor rated current), use fuses with a rated current
immediately superior to 3 times the motor rated current.
PRESSURE RELIEF SYSTEM
Safety is a constructional feature at the switchboards.
During the internal arc fault the gases are directed into
the rear vent, thus preserving the safety of the
operator standing in front of the cubicle.
Tests have demonstrated the absence of dangerous
distortions or projections of elements in way
of the station front panel.
DISCONNECTOR MONITORING
The disconnector control is shown on the mimic
diagram by the position of a rod directly coupled to the
control shaft carrying the contacts without any intermediate
linkage. This provides a fail safe indication of the position
(open or closed) of the switch.
Circuit Breaker Compartment
VOLTAGE MONITORING
Voltage presence or absence is shown by means of
neon indicator lights connected to the capacitor dividers
mounted on each phase. Using the neon plugs, it is
possible to check the phase sequence of two adjacent
panels in a fail safe way, as shown on the sketch opposite.
•
•
•
Correct phase sequence:
Presence lights on. Test light off.
Incorrect phase sequence:
Presence lights dimming. Test light on.
No voltage condition without test light.
Light off.
Checking that cables which are not live is of major
importance prior to closing the earthing switch.
Hence the feature of the neon lamp which is a fail safe
system to indicate live cables.
OPTIONAL ACCESSORIES
•
•
•
•
DATA DEFINING THE
SWITCHBOARD
•
•
Shunt opening release
Gearmotor for spring charging
Auxiliary contacts
Additional key locks
•
•
•
•
•
•
•
INSTRUMENTS AND RELAYS
•
•
•
•
Disconnector and Earthing
Switch Control Panel
Digital protective relays
Indicating metering insturments
Current transformers
Voltage transformers
7
Single-line diagram
Layout of the switchboard, relative position
of the vairous units
Rated and service voltage
Frequency
Short-circuit current at service voltage
Rated current
Supply voltage for auxiliary services
Installation ambient
Switchboard accessories
MV Air Insulated Metal Enclosed Switchgears
ELIMSAN METAL ENCLOSED SWITCHGEARS TYPES AND DETAILS
TYPES
DESCRIPTION
1
2
TG21-01
INCOMING/OUTGOING CUBICLE WITH LOAD BREAK SWITCH
TG21-02
INCOMING/OUTGOING CUBICLE WITH SF6 C.B
X
TG21-02V
INCOMING/OUTGOING CUBICLE WITH VACUUM C.B
X
TG21-03
TRANSFORMER PROTECTION CUBICLE (W/O TRIPPING)
TG21-04
COUPLING CUBICLE WITH SF6 C.B AND DOUBLE DISCONNECTOR
X
TG21-04V
COUPLING CUBICLE WITH VACUUM C.B AND DOUBLE DISCONNECTOR
X
TG21-05
COUPLING CUBICLE WITH SF6 C.B
X
TG21-05V
COUPLING CUBICLE WITH VACUUM C.B
X
TG21-07
TRANSFORMER PROTECTION CUBICLE WITH C.T (W/ TRIPPING)
TG21-11
METERING CUBICLE
TG21-13
METERING CUBICLE WITH LOAD BREAK SWITCH
X
TG21-14
TRANSFORMER PROTECTION CUBICLE (W/ TRIPPING)
X
TG21-15
VOLTAGE TRANSFORMER CUBICLE WITH DISCONNECTOR
X
TG21-16
METERING CUBICLE WITH DISCONNECTOR
X
TG21-17
INCOMING/OUTGOING CUBICLE WITH DISCONNECTOR
X
TG21-18
BUS RISER CUBICLE
TG21-19
COUPLING CUBICLE WITH DISCONNECTOR
TG21-22
COUPLING CUBICLE WITH LOAD BREAK SWITCH
TG21-27
INCOMING/OUTGOING CUBICLE WITH SF6 C.B (WITH V.T)
X
TG21-27V
INCOMING/OUTGOING CUBICLE WITH VACUUM C.B (WITH V.T)
X
3
4
5
6
7
X
8
9
10
11
12
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
1
Disconnector Switch
5
Current Transformer
9
Fuses with 3P Tripping
2
Load Break Switch
6
Voltage Transformer
10
Fuses without 3P Tripping
3
SF6 Circuit Breaker
7
Protection relay
11
Earthing Switch
4
Vacuum Circuit Breaker
8
Capacitive Voltage Divider
12
Bushing Insulator
8
General
12 kV
17.5 kV
24 kV
36 kV
Rated voltage
12 kV
17.5 kV
24 kV
36 kV
Rated withstand voltage 50-60 Hz. 1 min.
28 kV
38 kV
50 kV
70 kV
Rated withstand voltage accross isolating distance 50-60 Hz 1 min
32 kV
45 kV
60 kV
80 kV
Rated impulse withstand voltage 1,2 / 50^s
75 Kv
95 kV
125 kV
170 kV
Rated impulse withstand voltage accross isolating distance 1,2 / 50 /xs
85 kV
110 kV
145 kV
195 kV
Rated current of transformer feeder
400/630 A
400/630 A
400/630 A
400/630 A
Atmosphere conditions
-5/+50 C°
-5/+50 C°
-5/+50 C°
-5/+50 C°
Load Break Switch
12 kV
17.5 kV
24 kV
36 kV
Rated mainly active load breaking current
400 A
400/630 A
400/630 A
400/630 A
Rated closed-loop breaking current
400 A
400/630 A
400/630 A
400/630 A
Rated cable-charging breaking current
25 A
25 A
25 A
25 A
Rated no-load transformer breaking current
10A
10A
10A
10A
Rated short-circuit making current (peak)
40 kA
40/50 kA
40/50/63 kA
40/63 kA
Rated short-time current. 1 s (rms)
16kA
16/20 kA
16/20/25 kA
16/25 kA
0.5 Bar
0.5 Bar
0.5 Bar
0.5 Bar
Earthing -switch
12 kV
17.5 kV
24 kV
36 kV
Rated short-time current, 1 s (rms)
16 kA
16/20 kA
16/20/25 kA
16/25 kA
40/50 kA
40/50/63 kA
40/63 kA
400/630 A
12 kV
17.5 kV
24 kV
36 kV
292 mm
442 mm
442 mm
537 mm
Maximum power dissipate value
75 W
75 W
75 W
75 W
Main Dimensions
12 kV
17.5 kV
24 kV
36 kV
Height (mm)
1950
1950
1950
2250
Wide (mm)
750/500/375
750/500/375
900/500
1150/1000/750
Depth (mm)
1000
1000
1000
1400
Rated relative filled pressure for SF6 load break switch at 20 C°
Rated short-circuit making current (peak)
Fuses (Striker fuse units according IEC 60282)
Dimensions (Medium Type)
9
MV Air Insulated Metal Enclosed Switchgears
ELIMSAN METAL ENCLOSED SWITCHGEARS TYPES
AND DETAILS
MV Air Insulated Metal Enclosed Switchgears
TG21-XX SWITCHGEAR TYPES
10
SYMBOLS
11
MV Air Insulated Metal Enclosed Switchgears
MV Air Insulated Metal Enclosed Switchgears
ELIMSAN MODULAR CUBICLES MAIN COMPONENTS
Elimsan Medium Voltage
Circuit Breaker
Elimsan Voltage
Detoctor Systems
Elimsan Medium
Voltage Fuses
Elimsan Medium Voltage
Voltage Transformers
Elimsan Medium Voltage
Current Transformers
Elimsan Medium Voltage
Earthing Switches
12
MV Air Insulated Metal Enclosed Switchgears
LEGEND
13
MV Air Insulated Metal Enclosed Switchgears
TG21-13-36 Metering With
Load Break Switch
TG21-14-24 Transformer
Protection with LBS
TG21-01-36 Incoming and Outgoing
With Load Break Switch
TG21-01-24 Incoming and Outgoing
With Load Break Switch
TG21-02-36 Transformer
Protection With CB and CT
TG21-02-24 Transformer
Protection With CB and CT
INFORMATION ABOUT THE ACCESSORIES
EQUIPMENT
VOLTAGE
POWER
Motor
24,48,110,VDC
340 W
Tripping Coil
24,48,110,VDC
80 VA
Closing Coil
24,48,110,VDC
80 VA
Auxiliary Switch
10 A -220VAC
14
CONTACT
QUANTITY
4NO + 4NC,6NO + 6NC
8NO + 8NC
TG21-XX Metal Enclosed cubicles are produced according to the latest standards and norms as the
following.
TG21-XX Metal Enclosed cubicles have been designed to meet the requirements of international standards
(IEC), and validated by type tests, caried out by independent laboratories. These independent laboratories are
as follows:
IEC 62271-100
IEC 62271-102
IEC 62271-200
IEC 60265-1
IEC 60420
The following routine test are carried out before the
final control in factory. These test report together with
switchgear are submitted to customer.
• Power frequency withstand voltage test
• Auxilary and control circuit withstand voltage test
• Main circuit resistance measurement
• Design control and visual check
• Interlocking control
• Paint quality control
• Wiring control
15
MV Air Insulated Metal Enclosed Switchgears
QUALITY
Note : Elimsan’s policy is continuous development and improvement. Therefore the right is reserved to supply products which may differ in detail from those described and illustrated in this publication.
Elimsan Switchgear Equipment
and Electromechanics Industry
and Trade, Inc.
IZMIT / TURKEY
Tel : 90 262 375 23 60
Fax : 90 262 375 23 22
eli@elimsangroup.com
elimsanuretim@elimsangroup.com
www.elimsangroup.com