Quantis Configurator Updates

advertisement
Quantis Configurator Updates
Quantis Configurator Updates
The updated Quantis Configurator offers two user friendly selection
options.
Catalog Number – Offers a Quick Selection option based on nomenclature. This tool
would be used if you already have the nomenclature available from a reorder, catalog
selection or previous selection.
Reducer Selection- Uses images to guide you through a selection based on ratings
and features.


2
| © Baldor Electric Company
Quantis Configurator Updates
Catalog Number Selection
Select the highlighted “Catalog Number” button shown below.
 Offers a Quick Selection option based on nomenclature. This
tool would be used if you already have the nomenclature
available from a reorder, catalog or previous selection.
3
| © Baldor Electric Company
Quantis Configurator Updates
Catalog Number Selection
On the Catalog Config Tab- Select the desired input catalog string
using the drop down boxes provided from left to right. Each
selection will filter the next available selections. Use the white
arrow to the far right to reset.
4
| © Baldor Electric Company
Quantis Configurator Updates
Catalog Number Selection
 As you select your input catalog string, you will notice the Catalog Number
box in the Right Navigation Panel populate.
After the input catalog
string has been populated,
you will have additional
selection fields appear.
NOTE: Required fields open
up additional selection
options. This provides clear
guidance on information
required for complete
selection.
*Prime Mover/Rating (required field)
• Selection of Input Power (HP), Input Power (KW), Output torque (in-lbs), Output Torque (NM).
Defaults to HP or KW, depending on the input catalog string selected. NEMA input frame will default to HP. IEC input
frame will default to KW.
*Input Speed (RPM) (required field)
• Selection of 960, 1160, 1450, 1750, 2875, 3450
Input rpm must be selected regardless of Prime Mover/Rating selected. This selection launches the Standard Catalog
data Pop Up for the reducer selection based on the input catalog string.
5
| © Baldor Electric Company
Quantis Configurator Updates
Catalog Number Selection
Select the unit based on appropriate ratio/output rpm in the Standard
Catalog Data pop up box.
6
| © Baldor Electric Company
Quantis Configurator Updates
Catalog Number Selection
A standard configuration can be
completed on the Catalog Config
tab. Once all required fields have
been selected on this initial tab,
then the remaining tabs will open.
Right Navigation Panel
 Pricing Detail Box- List price
details are expanded. This can
be collapsed by clicking “View
Summary”.
 Catalog Number Box- Shows
complete catalog number for
selection.
 Exact Match Part
 Alternate Parts
 Drawings Box- Provides PDF
and CAD drawings for
selection.
7
| © Baldor Electric Company
Quantis Configurator Updates
Reducer Selection
Select the highlighted “Reducer Selection” button shown below.
 Uses images to guide you through a selection based on ratings and
features.
8
| © Baldor Electric Company
Quantis Configurator Updates
Reducer Selection
Reducer Specification Tab




Initial Selection is based on
Product Type (ILH, RHB, or
MSM) and associated output
configuration (Foot, Flange).
MSM has universal housing.
Ultra Kleen has separate
selection path.
Click on the desired picture
to start selection.
9
| © Baldor Electric Company
Quantis Configurator Updates
Reducer Selection- Reducer Specifications Tab
Required fields will be marked with Red *asterisks and must be populated in order to progress to the
next field.
*Prime Mover/Rating- Selection of Input Power (HP), Input Power (KW), Output torque (in-lbs), Output
Torque (NM).
*Input Speed (RPM) - Selection of 960, 1160, 1450, 1750, 2875, 3450
*Output Method- Select either Ratio or Output rpm
*Desired Ratio or Desired Output rpm (based upon previous selection)
*Input Configuration Image- Select the input type desired.
10 | © Baldor Electric Company
Quantis Configurator Updates
Reducer Selection
Reducer Specification Tab
NOTE: HP or KW value must be selected in
order to restrict the selection results and/or
calculate actual service factor.
*Input Configuration Image- Select the input
type desired.
Motor Type will default to NEMA or IEC
depending on Prime Mover/Rating selected
(HP or KW)
*Motor Frame- restricted by IEC or NEMA
and HP value (if selected).
Once Motor frame has been selected, this
will launch the Standard Catalog Data Box.
11 | © Baldor Electric Company
Quantis Configurator Updates
Reducer Selection
Output/Flange/Mounting Tab


Select Output Shaft type by clicking on
the image.
Grouped by:
› Solid Shaft options
• Single Extension Solid- A side
• Single Extension Solid- B side
• Double Extension Solid
› Keyed Hollow Bore options
• Straight Hollow Bore
• Tapered Hollow Bore
› Keyless Hollow Bore options
• Q-Loc Keyless Bushing
System
• Metric Bore Shrink Disc
12 | © Baldor Electric Company
Quantis Configurator Updates
Reducer Selection
Output/Flange/Mounting Tab

Once output shaft selection has
been made, then you will be able
to make additional selections
(when applicable).
›
›
›
›
›
›
›

*Output shaft UOM
*Output Shaft Bore/Dia.
*Mounting position
Incline Mounting
Screw Conveyor
Torque Arm Options
Backstops
Remaining tabs open up for
additional non required features
and selections.
13 | © Baldor Electric Company
Quantis Configurator Updates
Undo Catalog Selection





After selection is made from Standard Catalog Data screen, click the Undo Catalog Selection
button to select another rating.
Click Show Catalog Selection to select another reducer from the Standard Catalog Data box.
This can be used to select an other ratio/output rpm within the same size reducer selection
(Catalog Number selection).
It can also be used to select a different size reducer within the same ratio/output rpm variance.
(Reducer Selection)
Located on the Right Navigation Panel underneath the Catalog Number.
14 | © Baldor Electric Company
Quantis Configurator Update
Bearings/Seals/Lubrication Tab
 No changes were made to the Bearing/Seals/Lubrication Tab.
 Selections are the same for the Catalog Number and Reducer
Selection configuration options.
15 | © Baldor Electric Company
Quantis Configurator Updates
Reducer Options Tab
Reducer Options Tab has significant changes. Options are
grouped together with headings:

Environment
›
Ultra Kleen (will show Y when selected on initial
configurator page)
›
Reducer Protection Levels
›
Paint Color
›
TDNC Shaft Plating (will reflect Y when Washdown
and EZ Kleen Protection levels are selected)

Accessories (Select individually but also defaults when
other selections are made- i.e. A4 mounting position for
RHB, EZ Kleen or Washdown Protection Level, etc)
›
Washdown Breather
›
Breather Extension Kit
›
Oil Level Sight- Guage

Additional Options
›
Nameplate material option
›
Custom Nameplate
›
Certified Drawing

Delivery & Packaging
›
Long Term Storage
›
Delivery-24/48 Hour options
›
Packaging Type

Special Requirements
›
Special- Used for details on special configurations.
16 | © Baldor Electric Company
Quantis Configurator Updates
Reducer Protection Levels
Standard – indoor use, neutral atmospheres
›
Includes standard seals and paint

Severe Duty – indoor or outdoor use, protection from weather, humid conditions and precipitation
›
Includes XT Harsh Duty Output Seal, Washdown Breather and standard paint system (Dodge Blue Green)

Washdown Duty – indoor or outdoor protection from direct water sprays, occasional acidic or caustic chemicals,
exposure to salt atmosphere
›
Includes TDNC Shaft plating, XT Harsh Duty Output Seal, Viton Input Seal, Food Grade Lubricant,
Washdown Breather, Stainless Steel Epoxy Paint, Non Cavity Hardware

EZ Kleen – indoor or outdoor protection from high-pressure sprays with regular acidic or caustic content, brine
solution
›
Includes E-coating, TDNC Shaft plating, XT Harsh Duty Output Seal, Viton Input Seal, Food Grade
Lubricant, Washdown Breather, Stainless Steel Epoxy Paint, Non Cavity Hardware

ATEX-Provides legal requirements for the manufacturing of products that may be used in potentially explosive
environments. Directive 94/9/EC is required for European Union, and other countries.
›
Includes Viton Seals, Washdown Breather, Oil Sight Guage and standard paint.
Paint specifications

17 | © Baldor Electric Company
Quantis Configurator Updates
Motor Information Tab- C Face Motors

Baldor Stock Motor
› This motor option consists of STOCK motors that are currently loaded to the configurator.
They only apply to 1750 rpm NEMA motors. You can select your motor by filtering on the
required specs and motor category.
 Baldor Production
› This motor option includes any Baldor stock, non stock catalog number or spec number that
is NOT currently loaded in the configurator. This motor will be ordered by the Belton plant to
be assembled to the reducer. Conduit Box Position must be noted on the order. Belton
CANNOT order Mod X Motors or Custom Configured Motors that have not been assigned a
spec number. These must be ordered as Customer Supplied (see Other Motor). NOTE: Pricing
must be adjusted manually by Quantis Marketing to include the motor pricing.
 Other Motor- Customer Supplied Motors ONLY!
› This motor option is designated for all customer supplied motors, regardless of manufacturer.
This would include Baldor motors supplied by a district office, or a competitor motor supplied
by the customer. Sales order and model number are required for Baldor customer supplied
motors. Model number and Manufacturer name required for non Baldor motors.
Non standard Baldor Motors and Other Motor assemblies are subject to approval by Quantis Marketing
and the Belton Plant. Quotes will automatically go onto Baldor Review. Please contact Quantis
Marketing for review and approval.
18 | © Baldor Electric Company
Quantis Configurator Updates
Summary Tab
 Matches what will
print on formal quote
Reducer
Specifications.
 To print Summary,
right click in the
browser and select
print or print
preview.
19 | © Baldor Electric Company
Quantis Configurator Updates
 All PT PLACE procedures remain in place.
 Save to Local and Upload functions apply to all CustomQuantis
configurations.
 All special configurations must be reviewed and approved by
Marketing.
Questions??
20 | © Baldor Electric Company
Download