BURNDY® Grounding BURNDYWeld® Exothermic BURNDY® GROUNDMAX™ BURNDY® GROUNDMAX™ is an economical solution for areas with very difficult grounding issues. BURNDY® GROUNDMAX™ is highly conductive in a wet or dry application and does not require moisture to lower the resistance of your grounding system. BURNDY® GROUNDMAX™ contains a corrosion inhibitor which forms a film on copper, creating a barrier against corrosion. BURNDY® GROUNDMAX™ can be poured in dry or pumped in slurry form. No tamping required. It is very contractor friendly. No special tools required. 4 Thickness of BURNDY® GROUNDMAX™ (Inches) 2 3 4 5 6 7 8 9 10 4.1 6.2 8.2 10.3 12.3 14.4 16.4 18.5 20.6 BURNDY® GROUNDMAX™ Advantages: • Easy to install. • Electrically conductive. • Environmentally friendly. • Will not leach into the ground. • Positive low resistance, electrical connection to earth. • Does not contain any hazardous chemicals. • Compatible with all copper grounding systems. • Contains a corrosion inhibitor to protect copper. • Will not expand or shrink. • Not affected by freezing. • Excellent shelf life. • Typical resistivity <10 Ohm-cm Material Required Per Linear Foot of Trench Width of Trench (Inches) 6 8 10 12 14 6.2 9.3 12.3 15.4 18.5 21.6 24.7 27.8 30.8 8.1 12.1 16.2 20.2 24.2 28.3 32.3 36.4 40.4 10.1 15.2 20.2 25.3 30.3 35.4 40.4 45.5 50.5 12.1 18.2 24.2 30.3 36.4 42.4 48.5 54.6 60.6 14.1 21.2 28.3 35.4 42.4 49.5 56.0 63.7 70.7 E-87 16 18 20 22 24 16.2 24.2 32.3 40.4 48.5 56.6 64.7 72.7 80.8 18.2 27.3 36.4 45.5 54.6 63.7 72.7 81.8 90.9 20.2 30.3 40.4 50.5 60.6 70.7 80.8 90.9 101.0 22.2 33.3 44.5 55.6 66.7 77.8 88.9 100.0 111.1 24.2 36.4 48.5 60.6 72.7 84.9 97.0 109.1 121.2 To calculate the lbs. of material required to fill a trench: • Determine desired thickness. • Move to the right until you are under the known width of the trench. This number will be the weight of the material in lbs./linear ft. • Take this number and multiply by the length of the trench in feet. Your answer will be the amount of BURNDY® GROUNDMAX™ material required to fill the trench to the desired level in lbs. Example: Thickness: Width = = Answer = = 6 inches 18 inches 54.6 lbs. per linear ft. (from the table above) 54.6 lbs. per linear ft. x 25 ft. trench = 1,365 lbs. of BURNDY® GROUNDMAX™ 28 (50 lb.) bags of BURNDY® GROUNDMAX™ For mold types or BURNDYWeld® items not shown, please contact factory. Blue highlighted items are industry standard and most frequently ordered. US: 1-800-346-4175 www.burndy.com Canada: 1-800-387-6487 BURNDY® Grounding BURNDYWeld® Exothermic BURNDY® GROUNDMAX™ Application Information E-88 Vertical Installation Drill or bore a hole the desired diameter and depth. Suspend ground electrode in center of hole to be filled. Pour BURNDY® GROUNDMAX™ until desired level is obtained. No tamping is required. Dry Volume of BURNDY® GROUNDMAX™ vs. Hole Size Lbs. of Hole BURNDY® GROUNDMAX™ Size Per Ft. 4⬙ 6⬙ 8⬙ 10⬙ 12⬙ Horizontal or Grid Construction† Pour into horizontal trench until level of ground wire is reached. Place ground wire. Pour in additional BURNDY® GROUNDMAX™ until wire is covered to desired height. Cover with fill. No tamping required. For grid construction, pour BURNDY® GROUNDMAX™ and spread over ground grid until desired thickness is achieved. Cover with fill. Horizontal Construction Ground Resistance Comparison of Bare Rod vs. Hole Size with Percent Resistance 5/8⬙ x 10⬘ Rod in Compared to Rod Center of 15⬘ Hole Only (100%) 6.5 14.5 25.8 40.4 58.1 4⬙ 6⬙ 8⬙ 10⬙ 12⬙ 52% 47% 44% 42% 40% Steady State Leakage Resistance‡ Using 4/0 Copper Wire vs. BURNDY® GROUNDMAX™ Percentage of Resistance with .475⬙ Wire Plus BURNDY® GROUNDMAX™ in Various Diameters Compared .475⬙ Diameter to Wire Only (100%) Length 25⬘ 50⬘ 75⬘ 100⬘ 150⬘ 200⬘ 250⬘ 300⬘ Wire Only 100% 100% 100% 100% 100% 100% 100% 100% 2⬙ 83% 85% 86% 87% 88% 88% 89% 89% † Entire grounding system should be surrounded by BURNDY® GROUNDMAX™. Conductors should be insulated as they exit BURNDY® GROUNDMAX™ column. 3⬙ 78% 81% 82% 83% 84% 85% 85% 86% 4⬙ 74% 77% 79% 80% 82% 83% 83% 84% 6⬙ 69% 73% 75% 77% 78% 79% 80% 80% ‡ The use of BURNDY® GROUNDMAX™ around the grounding system will also reduce surge impedance by increasing the effective contact area of the electrode to soil. BURNDY® GROUNDMAX™ Copper Wire Earth or Fill Earth or Fill Grid Construction BURNDY® GROUNDMAX™ Copper Wire For mold types or BURNDYWeld® items not shown, please contact factory. Blue highlighted items are industry standard and most frequently ordered. Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175