Next Generation Disconnect Switches Bulletin 194R Fusible Disconnect Switches from 100…1250 A The new range of Bulletin 194R fusible disconnect switches expands up to 1250 A for IEC, and 800 A for UL applications. The new range combines premier performance, a compact footprint, and improved functionality The new 194R fusible disconnect switches have the following standard features: • Touch-safe design • OSHA padlocking • Double break switching for full fuse line and load side isolation when switch is OFF • Uses Bulletin 800F auxiliary contact blocks, reducing inventory To accommodate almost all control, Motor Control Center, and distribution applications, these disconnect switches are available in BS88, NFC, DIN, and UL/CSA versions. Non-Fusible Disconnect Switches from 100…1250 A The Bulletin 194R non-fusible disconnect switches are rugged, durable, and tested and approved for use in demanding applications and environments. This line up to 1250 A for IEC, and 1200 A for UL applications. Features of this new range of non-fusible disconnect switches include: • High performance • Compact design • Universal IEC/UL switch body • Severe utilization categories (AC-22 and AC-23) • High resistance to humidity The non-fusible disconnect switches exceed industry requirements for electrical and mechanical endurance and are designed to save panel space while meeting UL98, UL508A, CSA, IEC, and CE requirements. UL/CSA Non-Fused and Fused Disconnects 194R-NU800-1753 194R-NU200-1753 194R-J100-1753 194R-J600-1753 Catalog No String 194R-NU100* through 194R-NU1200* 194R-J100-1753 through 194R-J800-1753 Type UL/CSA Non-Fused disconnect switches UL/CSA Fused disconnect switches Features • 100, 200, 400, 600, 800, 1200A sizes • UL98 rating “Suitable as Sevice Entrance Disconnecting Means” • Compact footprint • Available in either 3 or 4-pole versions • 100, 200, 400, 600, 800A sizes • Touch-safe design • Front or side external operator • Double break design for full line & load isolation when in the OFF position. • Test position for analysis of auxiliary contact control circuit Voltage 600 VAC 600 VAC Current 100…1200A @ 600V 100…800A @ 600V Short Circuit 200 kA (100, 200, 400, 600 A disconnects) 100 kA (800, 1200 A disconnects) 200 kA Fuse Type J/HRCI-J Fuse (100, 200, 400 600 A disconnects) L/HRCI-L Fuse (800 A disconnects) J/HRCI-J Fuse (100, 200, 400, 600 A disconnects) L/HRCI-L Fuse (800 A disconnects) Ratings 30 through 200 HP@ 240V 75 through 500 HP @ 460V 100 through 500 Hp @ 600V 30 through 200 HP@ 240V 75 through 500 HP @ 460V 100 through 500 Hp @ 600V DC Ratings 10 through 20 HP @ 125V (2-poles in series) 15 through 50 HP @ 240V (3-poles in series) 7.5 through 20 HP @ 125V (2-poles in series) 20 through 50 HP @ 240V (3-poles in series) Handles Rotary operating with or without defeater Color – black or red/yellow 194R-HM series handle through 1200 A Ingress rating Type 1 or 3, 3R,12, 4, 4X Rotary operating with or without defeater Color – black or red/yellow 194R-HM series handle through 800 A Ingress rating Type 1 or 3, 3R,12, 4, 4X NFPA79 Handle Available through 600 A, includes operating shaft Available through 600 A, includes operating shaft Operating Shafts 320 mm (12.6”) or 560 mm (22”) option 320 mm (12.6”) or 560 mm (22”) option Auxilary Contacts (optional) up to 2 N.O./N.C. Form C contacts Up to 8 Bulletin 800F contact blocks Terminal Shields (optional) Offer line and load protection against contact with terminals Offer line and load protection against contact with terminals Line & Load Lugs (optional) Lug kits are available to cover single and dual conductor applications. Typically 3 or 4 lugs per kit. Lug kits are available to cover single and dual conductor applications. Typically 3 lugs per kit. Hardware Kits (optional) Bolt kits are available for use with customer supplied lugs or ring/crimp type conductors. Bolt kits are available for use with customer supplied lugs or ring/crimp type conductors. Conformity to Standards UL98, CSA 22.2 #4, IEC60947-3, CE Certified UL98, CSA 22.2 #4, NFPA79, IEC60947-3, CE Certified IEC Non-Fused and Fused Disconnects 194R-NE400-1753 194R-NE160-1753 194R-D160-1753 194R-D1250-1753 Catalog No String 194R-NE125-1753 through 194R-NE1250 194R-D125-1753 through 194R-D1250-1753 Type IEC Non-Fused disconnect switches IEC Fused disconnect switches Features • 125, 160, 250, 400, 630, 800,1250A sizes • IEC/EN 60947-3 rating…. • Compact footprint • Available in either 3 or 4-pole versions • 125, 160, 250, 400, 630, 800,1250A sizes • IP20 protection with terminal shields • Front or side external operator • Double break design for full line & load isolation when in the OFF position. • Test position for analysis of auxiliary contact control circuit Voltage 690 VAC 690 VAC Current 125…1250 A @ 400V 100…800 A @ 600V Short Circuit 50 kA (400,800 A disconnects) 70 kA (630 A disconnects) 100 kA (125,160,400, 1250 A disconnects) 200 kA (100 A disconnect) 100 kA (200, 400,600,800 A disconnects) Fuse Type BS, DIN, NFC BS, DIN, NFC Ratings 63 through 710 kW@ 400V 63 through 710 kW @ 500V 55 through 475 kW @ 600V 80 through 560 kW @ 400V 110 through 400 kW @ 690V DC Ratings 500VDC (4-pole device with 2-poles in series) 500VDC (4-pole device with 2-poles in series) Handles Rotary operating with or without defeater Color – black or red/yellow 194R-HM series handle through 1250 A Ingress rating IP42 or IP66 Rotary operating with or without defeater Color – black or red/yellow 194R-HM series handle through 1250 A Ingress rating IP42 or IP66 NFPA79 Handle Available through 600 A, includes operating shaft Available through 600 A, includes operating shaft Operating Shafts 320 mm (12.6”) or 560 mm (22”) option 320 mm (12.6”) or 560 mm (22”) option Auxilary Contacts (optional) up to 2 N.O./N.C. Form C contacts Up to 8 Bulletin 800F contact blocks Terminal Shields (optional) Offer line and load protection against contact with terminals Offer line and load protection against contact with terminals Line & Load Lugs (optional) Lug kits are available to cover single and dual conductor applications. Typically 3 or 4 lugs per kit. Lug kits are available to cover single and dual conductor applications. Typically 3 lugs per kit. Hardware Kits (optional) Bolt kits are available for use with customer supplied lugs or ring/crimp type conductors. Bolt kits are available for use with customer supplied lugs or ring/crimp type conductors. Conformity to Standards IEC/EN60947-3, NBN/BS EN60947-3, VDE 0660-107, UL/CSA IEC/EN60947-3, NBN/BS EN60947-3, VDE 0660-107, UL/CSA Bulletin 194R Accessories Terminal Shrouds Rotary Operating Handle • Offered for both line & load protection • With or without defeater • Offer IP20 protection for IEC fused disconnects • Color black or red/yellow 194R-HM4E Handle • Ingress ratings: IP42 or 66 (Type 1 or Type 3R,3,12,4,4X) Shafts for External handles Shaft Guide • 320 mm (12.6”) or 560 mm (22”) Compensates for slight misalignment between shaft and external handle. Use with shafts lengths over 400 mm (15.75”) 194R-HS62 194R-R7 Lug Kits Contact Blocks Available for single or two conductor per lug. Used with hardware kits to connect lugs to terminals Uses Bulletin 800F contact blocks for all fused disconnects and NO/NC Form C auxiliaries for Non-fused disconnects 800F-X10 NFPA79 Internal Handle w/shaft Bulletin 194R 30 & 60 A Fused & Non-Fused Disconnects Includes NFPA79 handle and 8 mm or 9.5 mm square operating shaft. These disconnect switches are UL Listed and CSA Certified. They are designed to meet IE 60947-3, VDE, DIR, BS and applicable NEMA requirements. 194R-HM4-NFPA1 194R-J30-1753 Allen-Bradley is a trademark of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Publication 194R-PP005A-EN-P – March 2012 Copyright © 2012 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.