Fire Alarm Systems | CH90 Series Multi-candela Chime Strobes CH90 Series Multi-candela Chime Strobes ▶ Low current draw with temperature compensation to reduce power consumption and wiring costs ▶ 24 VDC, filtered or FWR ▶ Adjustable volume and tone ▶ Single‑stroke or vibrating tone ▶ Selectable strobe intensities of 15 cd, 30 cd, 75 cd, or 95 cd ▶ Strobes flash once per second over the regulated voltage range These Wheelock CH90 Multi-candela, Ceiling-mount Chime Strobes provide low current draw, choice of single-strike or vibrating operation, adjustable sound level, chime tone adjustable from 800 Hz to 1200 Hz, and choice of four light output intensities (15 cd, 30 cd, 75 cd, or 95 cd) in one unit. The strobes can be synchronized using SM (single) or DSM (dual) modules. They also have an attached mounting plate for easy indoor installation on a variety of electrical boxes. Functions Strobe Settings The unit comes set at 15 cd. Change the setting using a screwdriver in the slot in the unit's base (setting is visible on indicator plate within the lens). Volume and Tone Settings The volume and tone controls are factory set to ensure maximum dBA output; however, the volume and tone can be tuned to suit a particular application. Take appropriate measurements to ensure the volume meets the listing requirements for private mode fire protective service per UL464. Sound Mode Settings The chimes are factory set in single-stroke mode. They can be changed to vibrating mode before wiring by moving a jumper. Single-Stroke Mode The minimum input pulse duration must be at least 160 ms on and 160 ms off. The chime only operates once each time it is pulsed. Use this mode for coded systems. Vibrating Mode Apply continuous input voltage to the chime to activate the chime at 1 sec intervals. Certifications and Approvals Wheelock, Inc. holds these Listings and Approvals: Listings and Approvals UL UCST: Audible Signal Appliances, General Signal (UL464) UL ULSZ: Audible Signal Appliances (UL464) UL UUKC: Signaling Appliances and Equipment for the Hearing Impaired (UL1971) CSFM 7125-0785: 151 NYC/MEA (151‑92‑E, Vol. 40; 151‑93‑e, Vol. 40) Complies with: Americans with Disabilities Act (ADA) American National Standards Institute (ANSI), International Standards Organization (ISO), and National Fire Protection Association (NFPA) temporal pattern www.boschsecurity.com 2 | CH90 Series Multi-candela Chime Strobes Federal Communications Commission (FCC Part 15, Class B RFI limits) Technical Specifications Occupational Safety and Health Administration (OSHA 29 Part 1910.165 Environmental Considerations Installation/Configuration Notes Relative Humidity: Up to 85%, non‑condensing Temperature (Operating): +32°F to +120°F (0°C to +49°C) Chime Ratings at 24 VDC Compatible Products The following products are compatible with the CH90 Series Chime Strobes: Reverberant dBA at 10 ft (3 m) per UL464: Maximum: 58 dBA Minimum: 52 dBA Mechanical Properties Category Product ID Product Description D70221 Conventional FACP Dimensions (diameter x D): 7.25 in. x 2.9375 in. (18.4 cm x 7.5 cm) Control Panels D70242 Addressable FACP Material: D7024 Conventional FACP Molded plastic enclosure with Xenon flashtube and Lexan® lens D80241 Analog FACP Power Requirements D91241 Addressable FACP D10024A1 Analog FACP Chime Current (maximum): 22 mA SM-12/24-R Synchronization module (red) Voltage (input) 24 VDC nominal, filtered or FWR DSM-12/24-R Dual synchronization module (red) Modules For synchronization, use the SM or DSM modules with these control panels. The synchronization module must be set for 24 V operation. When used, the D7022 must be set for 24 VDC operation. 2 When used with a D7039 Multiplex Expansion Module, the D7024 becomes an addressable fire alarm control panel (FACP). Strobe Current (maximum): 15 cd: VDC: 65 mA FWR: 110 mA 30 cd: VDC: 105 mA FWR: 170 mA 75 cd: VDC: 189 mA FWR: 280 mA 95 cd: VDC: 249 mA FWR: 375 mA 1 Trademarks Mounting Considerations Mount these chime strobes on the indicated back boxes for the indicated applications: Conduit Applications Surface Mounted Four-inch square* SBB Back Box Flush Mounted • • * Requires a four-inch square back box that is 2.125 in (5.4 cm) deep with a 1.5 in. (3.8 cm) deep extension ring. Lexan® is a registered trademark of General Electric Corporation, USA, in the United States and other countries. Ordering Information CH90-24MCC-FR Multi-Candela Chime Strobe (red) CH90-24MCC-FR CH90-24MCC-FW Multi-Candela Chime Strobe (white) CH90-24MCC-FW Hardware Accessories ISP2-R Surface Adapter (red) ISP2-R ISP2-W Surface Adapter (white) ISP2-W Wiring RP-R Retrofit Plate (red) RP-R The input terminals accept wires with diameters between 18 AWG (1.2 mm) and 12 AWG (2.3 mm). SBB-R Surface-mount Back Box (red) SBB-R SBB-W Surface-mount Back Box (white) SBB-W SBL2-R Retrofit Device Back Box (red) SBL2-R SER-R Square Semi-flush Extension Ring (red) SER-R SER-W Square Semi-flush Extension Ring (white) SER-W Parts Included Quant. Component SFP-R Semi-flush Plate (red) SFP-R 1 Chime Strobe SSB-4 Ceiling Support Bridge SSB-4 1 Hardware pack 1 Literature pack CH90 Series Multi-candela Chime Strobes | 3 Americas: Bosch Security Systems 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 585 223 4060 Fax: +1 800 289 0096 security.sales@us.bosch.com www.boschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: +31 40 27 83955 Fax: +31 40 27 86668 emea.securitysystems@bosch.com www.boschsecurity.com © Bosch Security Systems 2006 | Data subject to change without notice F1584560779 | Cur: en-US, V2, 9 Feb 2006 Asia-Pacific: Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Phone: +65 6319 3450 Fax: +65 6319 3499 apr.securitysystems@bosch.com www.boschsecurity.com Represented by