CAT.EUS70-35A'-UK Valve for Water and Chemical-based Fluids (2/3 Port Air Operated Valve) Applicable for 2 types of liquid paint (VCC12D) PTFE diaphragm structure = Sliding part eliminated Less paint adhesion Mountable on a robot arm (space-saving, lightweight) 2 valves per station (30 mm pitch) 2/3 port valves mixed mounting Resin manifold block 50 2700 g 12 Weight: 0 212 ATEX Explosion protection SUS316L Stainless steel fitting Series VCK Series VCC / ø6 to ø12 2 port ··· 6 valves 3 port ··· 6 valves Fitting ···19 pcs. 2 port valve 3 port valve VCC12(D) VCC13 Paint Line System (Application example) Water/Chemical-based Paint, Pure Water, Cleaning Solvent type Paint circulation (for 3 port valves) Paint gun Built-in 2 port valve Painting RETURN IN OUT Regulator Paint supply (Direct supply possible) (Max. 40 colours) Selects paint colour. 2/3 port valve Completely separates the paint valve and the cleaning valve, so the paint does not enter the cleaning side. Gate valve (2 port) (Built in the manifold) IN Cleaning fluids • Thinner • Pure water • Water solvent • Air Cleaning valve (2 port) VCC manifold 2 port valve (VCC12) IN Leakage detection port 3 port valve (VCC13) Pilot signal Open OUT Leakage detection port IN Switch indicator light (Blue) Pilot signal Switch indicator light (Blue) Open OUT Closed Closed Leakage detection port IN RETURN Paint leakage to the pilot piping can be checked visually. Even when leakage occurs, there is no backflow between the paint and pneumatics. 2 types of Liquid Paint/PTFE Diaphragm Single Paint, Solvent, Ink Control type/Single Unit PAT. Diaphragm OUT IN Leakage detection port Pilot signal 2 port valve (VCC12(D)) Switch indicator light (Red) 3 port valve (VCC13) PA PA IN IN Open Closed OUT OUT RETURN Features 1 Manifold Valve Separable Resin Manifold Block Easy addition and reduction of stations Tough PPS (Polyphenylene Sulfide) resin is used. Fluororesin is contained. (Less fluid adhesion) Antistatic (Surface resistance 102 to 105Ω) IN port SUS316L Stainless steel fittings are standardized. Stainless Steel 40° swivel elbow centralises piping. Leakage detection port Gate/Cleaning valve IN PA IN PA 2/3 port valve RETURN RETURN RETURN IN PA IN PA IN PA IN PA IN PA Cleaning valve Gate valve OUT 2 port valve OUT port IN PA PA Gate valve IN PA IN PA IN PA IN PA IN PA RETURN RETURN RETURN 2 port valve manifold block assembly 3 port valve IN port RETURN port PA (pilot) port 3 port valve manifold block assembly Clip Antistatic one-touch fitting Easy attachment/removal with a clip. No seal tape necessary. (Conductive) Reduction of the paint deposit Surface sealed with resin + O-ring (Supplemental seal) Cartridge type valve The valve can be replaced without touching the piping. Less build-up of liquid → Better cleaning performance, mixing of the colours reduction Liquid build-up at valve is 0.01 cc or less. Ensures stable sealing performance in case of misalignment. Spherical surface + Tapered shape Special fluororesin seal Even if the sphere is worn out, The O-ring back-up ensures sealing performance. PAT. Indicator function Standard (Sliding type) Diaphragm type Operating condition can be checked visually or by touching. Indicator color Blue ··· VCC12, 13 Red ··· VCC12D Features 2 SUS316L Stainless Steel Fitting Single Unit 2 port valve IN VCKH VCKK VCKL Male connector 40° swivel elbow 90° swivel elbow PA (pilot) port OUT OUT PA IN Leakage detection port 3 port valve IN 40° swivel elbow is added in line-up. Seal tape is unnecessary. No chance for insulation. (Applicable for paint with high voltage) Attachment/removal in a narrow space is easy. PA (pilot) port IN OUT PA OUT RETURN RETURN port Leakage detection port Type Model Male connector VCKH 40° swivel elbow VCKK 90° swivel elbow VCKL Port size Applicable tubing O.D. x I.D. G1/4 6x4 8x6 10 x 8 10 x 7.5 12 x 9 Special Tools Disassembly and maintenance are possible. Product design takes maintenance performance into consideration. Attaching/Detaching the valve Disassembling/Cleaning the valve element Attaching/Detaching the tubing Special tool Special tool Special tool Special tool (for socket wrench) Made to Order Check valve Regulator Note) Also applicable to special manifold. Features 3 Valve for Water and Chemical Base Fluids (2/3 Port Air Operated Valve) Series VCC I N D E X How to Order Page 1 Specifications/Weight Page 3 Dimensions Single valve unit Page 5 Manifold Page 6 SUS316L Stainless steel fitting Page 7 Special Tools Disassembly/Assembly/ Maintenance Procedure Page 9 Page 11 Replacement Parts Page 13 Safety Instructions Back page 1 Specific Product Precautions Back page 2 Front Matter 1 Valve for Water and Chemical-base Fluids (2/3 Port Air Operated Valve) Series VCC II 2GD c 75°C (T6X) Please refer to “Manifold Specification Sheet” in the back of page 6. How to Order Valve VCC1 2 00 Passage number 2 port valve 2 3 port valve 3 2D 2 port/Diaphragm type (Applicable for 2 liquid paint) Port size 00 For manifold mounting 02 Rc1/4 (for single unit) Note) 02F G1/4 (for single unit) Note) VCC12(D)-00 VCC13-00 VCC12(D)-02(F) VCC13-02(F) Note) Part number for sub-base [Rc1/4] For 2 port: VCC12-S- 02 02F [G1/4] [Rc1/4] For 3 port: VCC13-S- 02 02F [G1/4] Manifold Standard VV M CC1 06 06 C4 Pilot port fitting size Type (Passage number) 2 3 M C4 C6 2 port valve, Cleaning valve 3 port valve 2/3 port valves mixed mounting 2 port valve mountable number 00 02 04 No 2 port valves used 2 pcs. (colours) 4 pcs. (colours) ø4 one-touch fitting (Antistatic) ø6 one-touch fitting (Antistatic) 3 port valve mountable number 00 02 04 No 3 port valves used 2 pcs. (colours) 4 pcs. (colours) Note) Maximum mountable valve number: 40 pcs. (total of 2 port and 3 port valves) Circuit example 2 port valve IN PA IN PA IN PA 3 port valve 2 port valve 1 pc. 3 pcs. 5 pcs. RETURN RETURN RETURN IN PA IN PA IN PA OUT 2 pcs. 4 pcs. IN PA IN PA IN PA IN PA IN PA IN PA RETURN RETURN RETURN Note) ATEX Explosion Protection for 2/3 port air operated valves and manifolds is also applicable to made-to-order versions except for models made of aluminium. 1 6 pcs. 2 pcs. 4 pcs. 6 pcs. 3 port valve 1 pc. 3 pcs. 5 pcs. Valve for Water and Chemical-base Fluids Series VCC How to Order Manifold With gate valve VV M CC1 06 06 C4 G 04 Passage number Gate valve and cleaning valve mountable number 2 2 port valve, Cleaning valve M 2/3 port valves mixed mounting 02 04 06 2 port valve mountable number 00 02 04 Pilot port fitting size 3 port valve mountable number No 2 port valves used 2 pcs. (colours) 4 pcs. (colours) 00 02 04 C4 ø4 one-touch fitting (Antistatic) C6 ø6 one-touch fitting (Antistatic) No 3 port valves used 2 pcs. (colours) 4 pcs. (colours) ∗ The gate valve and cleaning valve (2 port valve) are not included. They are ordered separately. (Gate valve is equivalent to 2 port valve.) ∗ When cleaning valve number is an even number, use the blanking plug for 2 port valve. Note) Maximum mountable valve number: 40 pcs. (total of 2 port, 3 port and gate valves) Circuit example 2/3 port valve Gate/Cleaning valve IN PA IN PA Cleaning valve (2 port valve): 1 pc. + Gate valve: 1 pc. Cleaning valve (2 port valve): 3 pcs. + Gate valve: 1 pc. Cleaning valve (2 port valve): 5 pcs. + Gate valve: 1 pc. IN PA Cleaning valve RETURN RETURN RETURN IN PA IN PA IN PA Cleaning valve OUT Cleaning valve OUT Gate valve PA IN PA IN PA Gate valve IN PA IN PA IN PA RETURN RETURN RETURN SUS316L Stainless steel fitting Note) ATEX Explosion Protection for 2/3 port air operated valves and manifolds is also applicable to made-to-order versions except for models made of aluminium. VCK K 0604 02F Port size Shape H K L 02F Male connector 40° swivel elbow 90° swivel elbow G1/4 ∗ G1/4 bottom seal has a special shape. Please refer to page 7 for details. Applicable tubing (O.D. x I.D.) 0604 6 x 4 0806 8 x 6 1075 10 x 7.5 1008 10 x 8 1209 12 x 9 VCKH Male connector VCKK 40° swivel elbow VCKL 90° swivel elbow Option Blanking Plug Assembly Type Model For a 2 port valve VVCC12-10A-1 For a 3 port valve VVCC13-10A-1 Description Blanking plug (with O-ring) Qty. 1 Hexagon socket head plug (R1/4) 1 Blanking plug (with O-ring) 1 Hexagon socket head plug (R1/4) 2 2 Series VCC Specifications Model Passage number Construction (Fluid contact material) VCC12 VCC13 2 port 3 port VCC12D 2 port (Diaphragm type) Poppet seal (PEEK resin + Stainless steel) + Special fluororesin sliding part Fluid Poppet seal (PEEK resin + Stainless steel) + Special fluororesin diaphragm Water/Chemical-based paint, Ink, Cleaning solvent (Water, Butyl acetate), Air Operating pressure range (MPa) 0 to 1.0 (Instantaneous pulsation pressure: 1.2) 0 to 0.7 (Instantaneous pulsation pressure: 0.9) Withstand pressure (MPa) Pilot pressure (MPa) 0.4 to 0.7 Orifice size (mm) ø3.8 Effective area (mm2) 6 Fluid temperature (°C) ATEX explosion protection specification: 5 to 50 (T6X) Ambient temperature (°C) ATEX explosion protection specification: 5 to 50 (T6X) 2 Explosion proof construction 1.5 Explosion protection Lubrication Mounting orientation Valve leakage II 2GD c 75°C (T6X) Not possible (Default lubricant: White vaseline) Unrestricted (cm3/min) 1 or less (3 port valve IN → RETURN: 20 or less) Note 1) 1 or less Note 2) Note 1) Supply pressure: Valve leakage at 1.2 MPa (for air) Note 2) Supply pressure: Valve leakage at 0.9 MPa (for air) SUS316L Stainless Steel Fitting Specifications Applicable tubing Nylon/Fluoro tubing Fluid Water/Chemical-based paint, Ink, Cleaning solvent (Water, Butyl acetate), Air Max. operating pressure (at 20°C) (MPa) Ambient and fluid temperature 1.0 (°C) 0 to 60°C Weight Valve Blanking plug assembly Manifold block ∗ Valves are not attached. End plate VCC12 (2 port) 37 g VCC13 (3 port) 48 g For 2 port 29 g For 3 port 150 g For 3 port (2 stations, one-piece style) 254 g For gate valve 300 g For 2 port 409 g For 3 port 495 g For 2/3 port mixed mounting 452 g ø6 24 g ø8 25 g ø10 33 g ø12 36 g ø6 25 g ø8 26 g ø10 32 g ø12 37 g ø6 29 g ø8 30 g ø10 37 g ø12 41 g VCKH Fitting VCKK VCKL 3 45 g For 2 port (2 stations, one-piece style) Valve for Water and Chemical-base Fluids Series VCC Dimensions Mounting hole dimensions (When the valve is built into the device.) VCC12(D)-00 38.8±0.1 23±0.1 1.2 to 2 hole IN port 16.5±0.1 4 hole R0 OUT port .2 C 1 ø21.6±0.05 ø21±0.05 ø20±0.05 30° .2 R0 ø24±0.05 Pilot port 1.2 hole M26 3.8 hole Leakage detection port 30° 30° 2.5 8.5 33±0.1 40.8 ±0.1 45±0.1 ∗ The recommended insertion surface roughness is Rz6.3. VCC13-00 45.9±0.1 38.4±0.1 23±0.1 1.2 to 2 hole 4 hole 16.5±0.1 4 hole RETURN port Leakage detection port 1.2 hole Pilot port IN port R0.2 30° C 1 M26 3.8 hole ø23±0.05 ø22.5±0.05 ø22±0.05 ø24±0.05 OUT port 30° 30° 30° 2.5 32.7 8.5 ±0.05 40.5±0.1 48±0.1 55±0.05 ∗ The recommended insertion surface roughness is Rz6.3. 4 Series VCC Dimensions Single valve unit VCC12(D)-02(F) M5 leakage detection port 22 30 23 60 0.5 to 2 2 x ø6 (for M5 mounting) 6 48 G1/4, Rc1/4 OUT(2) port 22 25 43 25 6 22 15 15 38.7 16.5 Rc1/8 pilot (12) port 15 G1/4, Rc1/4 IN(1) port ∗ Part number for sub-base [Rc1/4] VCC12-S- 02 02F [G1/4] G1/4, Rc1/4 RETURN(3) port 11 19 M5 leakage detection port 30 VCC13-02(F) 23 38.4 70 0.5 to 2 2 x ø6 (for M5 mounting) 6 22 G1/4, Rc1/4 OUT(2) port 22 25 50 25 6 58 15 15 45.9 16.5 Rc1/8 pilot (12) port 15 G1/4, Rc1/4 IN(1) port ∗ Part number for sub-base [Rc1/4] VCC13-S- 02 02F [G1/4] 5 Valve for Water and Chemical-based Fluids Series VCC Dimensions 8 50 64.9 Manifold 10.5 Leakage detection port Pilot port C4: ø4 one-touch fitting C6: ø6 one-touch fitting G1/4 (IN port) 0.5 to 2 5 2 4 6 7 9 n-1 8 10 n L1 8 L2 4 x ø9 (for M8 mounting) 2 port valve 120 3 142.2 <144.2> 10 1 0.5 to 2 67.5 <69.5> G1/4 (RETURN port) 25 0.5 to 2 50 50 64.9 67.5 <69.5> 30 22.6 120 142.2 <144.2> 100 122.2 <124.2> 122.2 <124.2> 20 G1/4 OUT port 80 0.5 to 2 20 G1/4 OUT port 31 10 75 VV2CC1 100 VVMCC1, VV3CC1 3 port valve Pilot port C4: ø4 one-touch fitting C6: ø6 one-touch fitting G1/4 (IN port) 1 1 3 Gate valve 2 3 5 n-1 4 6 n 0.5 to 2 25 L1 8 L2 4 x ø9 (for M8 mounting) Cleaning valve + Gate valve 142.2 <144.2> 0.5 to 2 2 75 10 22.6 80 100 0.5 to 2 10 0.5 to 2 122.2 <124.2> G1/4 (RETURN port) 30 120 31 3 port valve 2 port valve < >: Pilot port is C6. L1 = n / 2 x 30 + 16 L2 = n / 2 x 30 + 32 ∗ n = Number of valves (cleaning valve + gate valve + other valves) n: Stations (mm) n 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 L1 L2 46 76 106 136 166 196 226 256 286 316 346 376 406 436 466 496 526 556 586 616 62 92 122 152 182 212 242 272 302 332 362 392 422 452 482 512 542 572 602 632 6 Series VCC Dimensions SUS316L Stainless steel fitting Mounting female thread recommended dimensions es s 9 to 11 7 or more G1/4 C 0. 5 or l ø4 or less Bottom seal Seal material: Nylon VCKH Male connector Width across flats E ø13 A 0.5 4.5 13.5 6 ≈C D ≈G ∗ After tightening manually, tighten 1.5 to 2 more turns. Width across flats F ø10 ∗ Tightening torque: Tighten within 10 ± 1 N m. G1/4 (mm) Part no. Indication of A øB C D E F G VCKH1209-02F VCKH1008-02F VCKH1075-02F VCKH0806-02F VCKH0604-02F 12/9 13 38.5 10 19 17 18.5 10/8 11 38 9 17 17 18.5 10·75 11 38 9 17 17 18.5 8/4 9 36.5 8 14 14 16 6/4 7 36.5 8 12 14 15 VCKK 40° swivel elbow 40° øB 10 ≈ F D A Width across flats 14 ≈C ∗ Tightening torque: Tighten within 10 ± 1 N m. ∗ After tightening manually, tighten 1.5 to 2 more turns. 0.5 2.8 5.8 11.8 13.8 18.8 Width across flats E ø8.6 ø11 G1/4 (mm) 7 Part no. Indication of A øB C D E F VCKK1209-02F VCKK1008-02F VCKK1075-02F VCKK0806-02F VCKK0604-02F 12/9 13 49.5 10 19 18.5 10/8 11 48.5 9 17 18.5 10·75 11 48.5 9 17 18.5 8/4 9 46 8 14 16 6/4 7 45.5 8 12 15 Series VCC Valve for Water and Chemical Base Fluids Dimensions VCKL 90° swivel elbow ≈E A Width across flats G F ≈H 10 0.5 2.8 11.8 5.8 13.8 D 18.8 Max. = C øB ∗ After tightening manually, tighten 1.5 to 2 more turns. ø8.6 Width across flats 14 ∗ Tightening torque: Tighten within 10 ± 1 N m. ø11 G1/4 (mm) Part no. Indication of A øB C D E F G H VCKL1209-02F VCKL1008-02F VCKL1075-02F VCKL0806-02F VCKL0604-02F 12/9 13 43.5 33 30.5 10 19 18.5 10/8 11 42.5 33 30 9 17 18.5 10·75 11 42.5 33 30 9 17 18.5 8/4 9 40 32 27.5 8 14 16 6/4 7 38.5 32 27.5 8 12 16 8 Special Tools Tool for Attaching/Detaching the Valve VCC-G-A Knurled ø8 4 x ø1.8 ø25 1 ø2 For attaching/ detaching the valve 104 M16 VCC-G-A VCC-G-B VCC-G-B (for socket wrench) Knurled 4 x ø1.8 ø28 1 ø2 Socket wrench A-type 6.3 square drive 24 Tool for Disassembling/Cleaning the Valve Element VCC12(D) 2 port valve VCC-G-C For 3 port valve Knurled ø8 ø19 ø1 2.7 3. ø1 4 x ø1.8 4 For 2 port valve 105 VCC13 3 port valve 9 4 x ø1.3 Valve for Water and Chemical-based Fluids Series VCC Union Nut Socket 1209 VCC-G-D- 12 VCC-G-D-1 (Applicable fitting VCK1008 ) 1075 13 Width across flats: 19 .5 25 14 60 VCC-G-D-2 (Applicable fitting VCK 0806 0604 ) 9 Width across flats: 17 5 20. 14 50 For extending the socket VCC-G-D-1 VCC-G-D-1 113 VCC-G-D-1 VCC-G-D-2 97 10 Disassembly/Assembly/ Maintenance Procedure Cleaning Valve Element Special tool part no.: VCC-G-C VCC13-00 (3 port valve) VCC12-00 (2 port valve) Body Body VCC13-1A-1 VCC12-1A-1 Valve element Orifice body assembly Valve element Orifice assembly 3 lines 2 lines Screw Screw Jig: VCC-G-C Procedure q Loosen the orifice body with a tool and remove it. w Clean the valve. e Assemble a new orifice body. VCC12(D)-00 (2 port valve) 0.2 Full length: 44.8 to 45.1 Except face seal (O-ring) VCC13-00 (3 port valve) 0.4 Full length: 54.6 to 54.9 Except face seal (O-ring) Tighten the screw until it hits the body by pressing the orifice body with approx. 100 to 200 N of force. (∗ Additional tightening is not necessary.) Control dimension with full length. (2 port valve: 44.8 to 45.1 mm, 3 port valve: 54.6 to 54.9 mm) Reference tightening torque is approx. 1 to 2 Nm for VCC12(D)-00 (2 port valve), and 0.5 to 1 Nm for VCC13-00 (3 port valve). There is a possibility of damaging threads if tightening exceeds the tightening torque range. 11 Valve for Water and Chemical-based Fluids Series VCC How to Remove the Valve Special tool part no.: VCC-G-A, VCC-G-B (Refer to page 9.) r q e Thread for detaching the body (M16) Procedure t Wipe off residual paint on the inner surface of the base with a cleaning material. y Replace the O-ring mounted to the valve. (O-ring part number: See page 13.) q Loosen the mounting nut. w Remove the indicator lamp cover. e Turn 45 to 90° (idle turn) clockwise with a tool (to avoid O-ring adhesion). r Pull out the valve straight. How to Attach the Valve Apply vaseline. Apply vaseline (commercially available) onto the O-ring surface and insert straight. (Note the direction shown in the label.) O-ring for paint Special FKM G1/4 After mounting the indicator lamp cover, tighten the mounting nut to a tightening torque of 2.5 to 3.5 Nm G1/4 IN IN Place the arrow within ±15° of IN port position. O-ring for air HNBR G1/4 RETURN Production lot number JAPAN ON OFF C12- 00 VC IS OUT OUT SMC IN port in valve 2 port valve IN port in valve Part no. 3 port valve Model label Attach and remove the valve straight. If the paint applied to the O-ring adheres to the pneumatic passage, clean it. When inserting, apply vaseline to the O-ring and the inner surface of the base and insert slowly so that the O-ring is not twisted or cut. The arrow shown on the model label of the valve is set to the optimum direction for cleaning. Mount the valve so that the arrow comes to IN port position. 12 Replacement Parts VVCC1: Manifold ∗ Tighten on a flat surface (e.g. holding plate) so that the end plates on both ends are not twisted. M5 Hexagon socket head cap screw Tightening torque: 3.5 ± 0.5 N m J D side K G1/4 port part Tightening torque: 10 ± 1 N m G ewq H ewq rqwe F q E w C A U side B D M5 Hexagon socket head cap screw Tightening torque: 3.5 ± 0.5 N m Block Assembly C: 2 port valve manifold block assembly D: 3 port valve manifold block assembly Manifold block assembly for gate valves M4 Round head combination screw Tightening torque: 1.2 ± 0.2 N m y w e r t r q e w o i q u t Component Parts Model VV2CC1 VV3CC1 VVMCC1 (common) VV3CC1 VVMCC1 13 Part no. VVCC12-OR-1 VVCC12-50A-L1C4 VVCC12-50A-L1C6 VVCC13-OR-1 Description O-ring between manifold blocks Symbol C-w D-t C-t ø4 one-touch fitting D-o ø6 one-touch fitting O-ring assembly between D-e port blocks D-r Component Material Qty. Order qty. O-ring Special FKM 1 10 set unit One-touch fitting — 1 O-ring HNBR 1 O-ring Special FKM 2 O-ring Special FKM 2 1 set unit 1 set unit Valve for Water and Chemical-based Fluids Series VCC 2/3 Port Valve A: 2 port valve Standard Diaphragm / 2 types of liquid paint VCC12-00 VCC12D-00 ywert i o !2 !0 !1 y i !3 u q u B: 3 port valve VCC13-00 et r y q w Component Parts Model Part no. Description Orifice body assembly VCC12-1A-1 (for VCC12-00) VCC12(D)-00 (dedicated) Orifice body assembly VCC12D-1A-1 (for VCC12D-00) VCC12-OR-1 O-ring assembly Orifice assembly VCC13-1A-1 VCC13-00 (dedicated) VCC13-OR-1 VCC12(D)-00 VCC13-00 (common) O-ring assembly Mounting nut assembly Symbol A-q Component Orifice body Material PEEK resin Qty. 1 A-w A-e A-r A-t A-y A-u A-!1 A-y A-u A-!2 A-!3 A-y A-u A-i B-q B-w B-e B-r B-w B-t B-y PTFE seal Special PTFE 1 O-ring Special FKM 1 Sleeve POM 1 O-ring Special FKM 1 O-ring Special FKM 2 O-ring Special FKM 1 Name plate — 1 O-ring Special FKM 2 O-ring Special FKM 1 Orifice body PEEK resin 1 Name plate — 1 O-ring Special FKM 2 O-ring Special FKM 1 O-ring HNBR 2 Orifice PEEK resin 1 O-ring Special FKM 1 O-ring Special FKM 1 Name plate — 1 O-ring Special FKM 1 O-ring Special FKM 3 O-ring HNBR 2 A-o Mounting nut Aluminum 1 A-!0 Switching display cover A-PET 1 VCC12-2A-1 Order qty. 1 set unit 1 set unit 1 set unit 1 set unit 1 set unit 1 set unit 14 Series VCC Parts Description Model Symbol A Part no. VCC12(D)-00 Description 2 port valve C4 VVCC12-1A-02F C6 ∗ Pilot port C4: ø4 piping C6: ø6 piping C C4 VVCC12-1G-02F C6 For 2 port valve ∗ Pilot port C4: ø4 piping C6: ø6 piping E F G B VVCC12-10A-1 VCC13-00 For 3 port valve E F Common H ∗ Pilot port C4: ø4 piping C6: ø6 piping VVCC13-2A-02F VVCC13-3A-1 VVCC13-10A-1 Material — Surface treatment — PPS resin — q Manifold block w — r Special FKM O-ring Tie-rod for adding stations Stainless steel Stainless steel Clip t One-touch fitting — — q U-side end plate Aluminium w Hexagon socket head cap screw with M5 SW q D-side end plate w Plug e O-ring r Hexagon socket head cap screw with M5 SW Blanking plug assembly for 2 port valve q Blanking plug w O-ring e 3 port valve Manifold block assembly for gate valves D-side end plate assembly for 2 port valves VVCC12-3A-1 C4 VVCC13-1A-02F C6 D Manifold block assembly for 2 port valves U-side end plate assembly for 2 port valves VVCC12-2A-02F Description — Symbol — Manifold block assembly for 3 port valves U-side end plate assembly for 3 port valves D-side end plate assembly for 3 port valves Blanking plug assembly for 3 port valves e Aluminium Stainless steel C4 For VVCC12-1A-02F C6 Hard anodized C4 For VVCC12-1G-02F C6 containing PTFE — — For adding stations — Refer to “Replacement Parts.” Hard anodized containing PTFE When the neighboring valve is a 2 port valve. — Aluminium Hard anodized containing PTFE POM — Special FKM — Stainless steel Note — When the neighboring valve is a 2 port valve. — POM — — Special FKM — — — — — R1/4 Hexagon socket head plug Stainless steel — — — — q Manifold block PPS resin — — Aluminium Hard anodized containing PTFE — w Port block e O-ring Special FKM — — r O-ring Special FKM — — t O-ring Special FKM — — y Round head combination Stainless steel screw with M4 SW — — u Tie-rod for adding stations Stainless steel — i Clip — o One-touch fitting Stainless steel — — q U-side end plate w Hexagon socket head cap screw with M5 SW q D-side end plate w Plug e O-ring r Hexagon socket head cap screw with M5 SW q Blanking plug w O-ring e R1/4 Hexagon socket head plug Stainless steel Aluminium Stainless steel For adding stations Refer to “Replacement Parts.” Hard anodized containing PTFE When the neighboring valve is a 3 port valve. — Aluminium Hard anodized containing PTFE POM — Special FKM — Stainless steel — POM — — Special FKM — — When the neighboring valve is a 3 port valve. — — J VVCC12-20A- Tie-rod — — Stainless steel — = Three manifold blocks make up one set. K VVCC12-21A Tie-rod for adding stations — — Stainless steel — Note) 3 pcs. make up one set. Note) When the manifold is shipped out, tie-rods for two extra stations are used. You can add or reduce 2 stations of manifold block (4 valves in total). Example) For manifold block 4 stations (8 valves) Tie-rod for 2 stations (VVCC12-20A-2) Tie-rod for adding stations (VVCC12-21A) Tie-rod for adding stations (VVCC12-21A) Example) For manifold block 5 stations (10 valves) Tie-rod for 3 stations (VVCC12-20A-3) 15 Tie-rod for adding stations (VVCC12-21A) Tie-rod for adding stations (VVCC12-21A) Valve for Water and Chemical-based Fluids Series VCC SUS316L Stainless Steel Fitting L M N Component Parts Model Symbol Part no. Description KFN-06-X2 K VCKL0604-02F H KFN-08-X2 K VCKL0806-02F H L Union nut KFN-10-X2 K VCKL-02F H K VCKL1075-02F H K VCKL1209-02F H KFS-06 K VCKL0604-02F H KFS-08 K VCKL0806-02F H Sleeve KFS-10 Qty. Order qty. C3604BD + Ni plated 1 1 set unit K VCKL1075-02F H Nylon 1 1 set unit Nylon 1 10 set unit K VCKL1008-02F H K VCKL1209-02F H KFS-12 VCKK-4-1 Material K VCKL1008-02F H KFN-12-X2 M N Conforming item Gasket 16 Series VCC Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of "Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO 4414 Note 1), JIS B 8370 Note 2) and other safety practices. Explanation of the Labels Labels Danger Warning Caution Note 1) Note 2) Note 3) Note 4) Explanation of the labels In extreme conditions, there is a possible result of serious injury or loss of life. Operator error could result in serious injury or loss of life. Operator error could result in injury Note 3) or equipment damage. Note 4) ISO 4414: Pneumatic fluid power – General rules relating to systems JIS B 8370: General Rules for Pneumatic Equipment Injury indicates light wounds, burns and electrical shocks that do not require hospitalization or hospital visits for long-term medical treatment. Equipment damage refers to extensive damage to the equipment and surrounding devices. Selection/Handling/Applications 1. The compatibility of the pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications. Since the products specified here are used in various operating conditions, their compatibility for the specific pneumatic system must be based on specifications or post analysis and/or tests to meet the specific requirements. The expected performance and safety assurance are the responsibility of the person who has determined the compatibility of the system. This person should continuously review the suitability of all items specified, referring to the latest catalogue information with a view to giving due consideration to any possibility of equipment failure when configuring a system. 2. Only trained personnel should operate pneumatically operated machinery and equipment. Compressed air can be dangerous if handled incorrectly. Assembly, handling or repair of pneumatic systems should be performed by trained and experienced operators. (Understanding JIS B 8370 General Rules for Pneumatic Equipment, and other safety rules are included.) 3. Do not service machinery/equipment or attempt to remove components until safety is confirmed. 1. Inspection and maintenance of machinery/equipment should only be performed once measures to prevent falling or runaway of the driven objects have been confirmed. 2. When equipment is removed, confirm that safety process as mentioned above. Turn off the supply pressure for this equipment and exhaust all residual compressed air in the system, and release all the energy (liquid pressure, spring, condenser, gravity). 3. Before machinery/equipment is restarted, take measures to prevent quick extension of a cylinder piston rod, etc. 4. If the equipment will be used in the following conditions or environment, please contact SMC first and be sure to take all necessary safety precautions. 1. Conditions and environments beyond the given specifications, or if product is used outdoors. 2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and brake circuits in press applications, or safety equipment. 3. An application which has the possibility of having negative effects on people, property, requiring special safety analysis. 4. If the products are used in an interlock circuit, prepare a double interlock style circuit with a mechanical protection function for the prevention of a breakdown. Examine the devices periodically if they function normally or not. Exemption from Liability 1. SMC, its officers and employees shall be exempted from liability for any loss or damage arising out of earthquakes or fire, action by a third person, accidents, customer error with or without intention, product misuse, and any other damages caused by abnormal operating conditions. 2. SMC, its officers and employees shall be exempted from liability for any direct or indirect loss or damage, including consequential loss or damage, loss of profits, or loss of chance, claims, demands, proceedings, costs, expenses, awards, judgments and any other liability whatsoever including legal costs and expenses, which may be suffered or incurred, whether in tort (including negligence), contract, breach of statutory duty, equity or otherwise. 3. SMC is exempted from liability for any damages caused by operations not contained in the catalogues and/or instruction manuals, and operations outside of the specification range. 4. SMC is exempted from liability for any loss or damage whatsoever caused by malfunctions of its products when combined with other devices or software. Back page 1 Series VCC Specific Product Precautions 1 Be sure to read this before handling. For Safety Precautions, refer to back page 1. For Precautions, refer to “Precautions for Handling Pneumatic Devices” (M-03-E3A). Design Piping Caution Warning 1. Cannot be used as an emergency shutoff valve, etc. The valves presented in this catalogue are not designed for safety applications such as an emergency shutoff valve. If the valves are used in this type of system, other reliable safety assurance measures should also be adopted. 2. Maintenance space The installation should allow sufficient space for maintenance activities. 3. When an impact, such as water hammer, etc., caused by the rapid pressure fluctuation is applied, the solenoid valve may be damaged. Handle with care. 1. Preparation before piping Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe. Install piping so that it does not apply pulling, pressing, bending or other forces onto the valve body. 2. Wrapping of pipe tape When connecting pipes, fittings, etc., be sure that chips from the pipe threads and sealing material do not enter the valve. Furthermore, when pipe tape is used, leave 1.5 to 2 thread ridges exposed at the end of the threads. Winding direction Ex po Selection se Warning 1. Confirm the specifications. Give careful consideration to the operating conditions such as the application, fluid and environment, and use within the operating ranges specified in this catalogue. 2. Fluid 1) Applicable fluids on the list may not be used depending on the operating condition. Give adequate confirmation, and then determine a model, just because the compatibility list shows the general case. 3. Air quality 1) Use clean air. Do not use compressed air containing chemicals, synthetic oils,organic solvents, salt or corrosive gases, etc., as it can cause damage or malfunction. 2) Install air filters. Install air filters close to the valves at their upstream side. A filtration degree of 5 µm or less should be selected. 3) Install an air dryer or after-cooler, etc. Compressed air that includes excessive drainage may cause malfunction of the valves and other pneumatic equipment. To prevent this, install an air dryer or after-cooler. 4) If excessive carbon powder is generated, eliminate it by installing mist separators at the upstream side of the valves. If excessive carbon powder is generated by the compressor, it may adhere to the inside of the valves and cause malfunction. Refer to SMC’s “Best Pneumatics” catalogue for further details on compressed air quality. 4. Ambient environment Use within the operable ambient temperature range. Confirm the compatibility between the product’s composition materials and the ambient atmosphere. Be sure that the used fluid does not touch the external surface of the product. 5. Countermeasures against static electricity Pipe tape ap pr ox .2 thr ea ds 3. Avoid connecting ground lines to piping, as this may cause electric corrosion of the system. 4. Always tighten threads with the proper tightening torque. When attaching fittings to valves, tighten with the proper tightening torque shown below. Tightening Torque for Piping Connection threads Proper tightening torque N m Rc 1/8 7 to 9 Rc 1/4 12 to 14 G 1/4 9 to 11 5. Connection of piping to products When connecting piping to a product, refer to its instruction manual to avoid mistakes regarding the supply port, etc. Operating Environment Warning 1. Do not use valves in atmospheres having corrosive gases, chemicals, salt water, water, steam, or where there is direct contact with any of these. 2. Do not use in locations subject to vibration or impact. 3. Do not use in locations where radiated heat will be received from nearby heat sources. 4. Employ suitable protective measures in locations where there is contact with water droplets, oil or welding spatter, etc. Take measures to prevent static electricity since some fluids can cause static electricity. Back page 2 Series VCC Specific Product Precautions 2 Be sure to read this before handling. For Safety Precautions, refer to back page 1. For Precautions, refer to “Precautions for Handling Pneumatic Devices” (M-03-E3A). Maintenance Caution 1. Filters and strainers 1) Be careful regarding clogging of filters and strainers. 2) Replace filter elements after one year of use, or earlier if the pressure drop reaches 0.1 MPa. 3) Clean strainers when the pressure drop reaches 0.1 MPa. 2. Storage In case of long term storage, clean after use with heated water and thoroughly remove all moisture to prevent rust and deterioration of rubber materials, etc. 3. Exhaust the drain from an air filter periodically. Back page 3 Series VCC Specific Product Precautions 3 Be sure to read this before handling. For Safety Precautions, refer to back page 1. For Precautions, refer to “Precautions for Handling Pneumatic Devices” (M-03-E3A). Design Maintenance Caution Warning 1. Leakage detection port The valve has a leak detection area to completely separate the fluid area from the pilot pressure area. If leakage is found, valve replacement and maintenance are necessary immediately. Fluids that solidify or cure may block the leak detection, so port and leak may not be detected. 2. If applying high voltage to the fluid, it must be earthed by using the bolt to mount the base. Do not use sealing tape when piping, as it may insulate. 1. Removing the product 1) Shut off the fluid supply and release the fluid pressure in the system. 2) Dismount the product. 2. Low frequency operation Switch valves at least once every 30 days to prevent malfunction. Also, in order to use it under the optimum state, conduct a regular inspection once half a year. 3. Stoppage of line When the line is stopped for a long time, clean the valve so that fluid (paint, ink, etc.) does not solidify or get cured. Selection Caution 1. Operating fluid Eliminate all solid material larger than 150 µm in the fluid to avoid valve failure. Piping Caution 1. Piping to pilot port Condensation may be formed in the piping to the pilot port, due to factors such as its length. The life of the valve will be shortened if condensed moisture enters the pilot port. To prevent condensation, the installation of a quick exhaust is recommended. Lubrication Caution 1. Do not lubricate the valve. The valve uses white vaseline as lubricant. Back page 4 Manifold Specifications Series VCC 1. How to Order a Manifold VV M CC1 06 10 C4 G04 q w q Type (Passage number) 2 port valve 2 3 port valve 3 M 2/3 port valves mixed mounting e r t ∗ This “How to Order” is that of the example below. w 2 port valve mountable number Note 1) 00 02 04 r Pilot port fitting size C4 C6 Without 2 port valve 2 pcs. (colours) 4 pcs. (colours) ø4 one-touch fitting ø6 one-touch fitting 40 40 pcs. (colors) Note 2) t Gate valve and cleaning valve mountable number Note 1) e 3 port valve mountable number Note 1) 00 02 04 – Without 3 port valve 2 pcs. (colours) 4 pcs. (colours) Without gate valve Note 3) Cleaning valve: 1 pc. + Gate valve: 1 pc. Cleaning valve: 3 pcs. + Gate valve: 1 pc. Cleaning valve: 5 pcs. + Gate valve: 1 pc. G02 G04 G06 40 40 pcs. (colors) Note 2) Note 1) Two valves can be installed per manifold block. Total valve number must be an even number. Note 2) Maximum valve number is forty (40) valves (colours) by a total of w + e + t. Note 3) When “Without gate valve” is selected, use 2 port valve of w as a cleaning valve. 2. How to Order a Valve 3. How to Order the Blanking Plug VCC1 2 00 VVCC1 2 10A 1 VCK K 1075 02F q q q Type (Passage number) 2 3 2D 4. How to Order the SUS316L Stainless Steel Fitting q Type (Passage number) 2 3 2 port valve 3 port valve 2 port/Diaphragm type q q Type (Shape) K L H For 2 port valves For 3 port valves Used when the number of valves used on the manifold base is an odd number. w w Piping port 1209 1008 1075 0806 0604 40° swivel elbow 90° swivel elbow Male connector Piping port for ø12 x ø9 Piping port for ø10 x ø8 Piping port for ø10 x ø7.5 Piping port for ø8 x ø6 Piping port for ø6 x ø4 Cleaning valve with gate valve Mountable number ∗ In this case, four (4) cleaning valves (including gate valve) Stations 2 1 2 port valve 3 port valve Mountable number Mountable number ∗ In this case, six (6) 2 port valves 1 3 5 ∗ In this case, ten (10) 3 port valves 1 3 5 7 9 Pilot port fitting IN port OUT port D side U side IN port Stations 3 Gate Cleaning unit (with gate valve) side Back page 5 2 4 6 Standard unit side 2 4 6 8 10 RETURN port SMC Corporation Manifold Specification Sheet (Series VCC: VVCC1) Fill in this format. Date: Year _____ / Month _____ / Date _____ Company name Department Person in charge Phone Fax Repeat Device description Drawing number Production number Repeat Not Repeat Ordered part number (Please order with this part number.) SMC use Manifold valve part no. C C 1- 0 0 V C C 1 Valve Specification Sheet ∗ Fill in the symbol for stainless steel fitting. For others, mark necessary items with a circle. Cleaning unit Note 2) (with gate valve) Unit Part number (Mountable valve number) G06 G04 G02 Stations Note 1) 4 2 port valve (Sliding type) VCC12-00 2 port valve (Diaphragm type) 5 2 3 1 Gate Standard unit 02 1 04 2 3 06 5 4 08 6 7 10 8 9 12 14 16 18 20 40 11 13 15 17 19 10 12 14 16 18 20 39 40 D side Description/Model 2 port valve Valve options To fill in the blanks in the manifold number, please refer to the symbols in the catalogue. Select the valve referring to the specification table. - V V VCC12D-00 Blanking plug for 2 port valve VVCC12-10A-1 U side (OUT port side) Manifold Fitting Piping port IN port Part number (Mountable valve number) 02 Stations Note 1) 1 3 port valve Valve Fitting options Description/Model Note 3) 04 2 3 06 5 4 08 6 7 10 8 9 12 14 16 18 20 40 11 13 15 17 19 10 12 14 16 18 20 39 40 3 port valve (Sliding type) VCC13-00 Blanking plug for 3 port valve D side VVCC13-10A-1 Piping port IN port U side (OUT port side) Note 3) Piping port RETURN port Select stainless steel fitting for IN, RETURN port from the table below, and enter the symbol into the specification table. Symbol A B C D E Description For piping ø12 x ø9 40° swivel elbow For piping ø10 x ø8 40° swivel elbow For piping ø10 x ø7.5 40° swivel elbow For piping ø8 x ø6 40° swivel elbow For piping ø6 x ø4 40° swivel elbow Part no. Symbol F G H J K VCKK1209-02F VCKK1008-02F VCKK1075-02F VCKK0806-02F VCKK0604-02F Description For piping ø12 x ø9 Male connector For piping ø10 x ø8 Male connector For piping ø10 x ø7.5 Male connector For piping ø8 x ø6 Male connector For piping ø6 x ø4 Male connector Part no. VCKH1209-02F VCKH1008-02F VCKH1075-02F VCKH0806-02F VCKH0604-02F Fill in the model number in the table below for connecting the fitting to the OUT port. (See SUS316L stainless steel fitting type.) For connecting the elbow union, the piping direction is on top (IN, RETURN port side). OUT port Stainless steel fitting V C K -0 2 F Note 1) Two valves can be installed per manifold block. Assign two valves in one square. Note 2) Please order a cleaning unit when the gate valve is necessary. Note 3) When the fitting is necessary for IN, RETURN port, please order by selecting the necessary stainless steel fitting symbol in the port of each station. For 40° swivel elbow, the piping direction is on D side. Serial No. Customer/SMC use Customer code Department code Date of delivery U/C Fill in for faxed order Customer’s order no. Code for person in charge Registered image no. SMC order no. Component list Part no. Qty. Part no. Qty. Part no. 1 6 11 2 7 12 3 8 13 4 9 14 5 10 15 Qty. Back page 6 Valve type 2 port valve Valve arrangement 7 pcs. 3 port valve 24 pcs. 1 pc. 4 pcs. Gate valve Cleaning valve C C 1- 0 0 V C C 1 ø8 x ø6 (40° swivel elbow) ø10 x ø8 (90° swivel elbow) One-touch fitting for ø4 ∗ Specify twelve (12) stations for manifold. Valve Cleaning unit Note 2) (with gate valve) G06 G04 G02 Stations Note 1) 4 2 port valve (Diaphragm type) 5 2 3 1 Gate Standard unit 02 1 04 2 3 06 5 4 08 6 7 8 VCC12D-00 Stations Note 1) Description/Model 3 port valve Valve options 16 18 20 40 39 40 When more than twenty valves are used, specify valve qty. in blank column. When the same valves and fittings are required, they can be specified by arrows. IN port Part number (Mountable valve number) Fitting 14 Blanking plug for 2 port valve VVCC12-10A-1 Note 3) 12 11 13 15 17 19 10 12 14 16 18 20 Although eight 2 port valves can be installed, if you need only seven valves, select the blanking plug. The plug is connected to the port with the blanking plug. Fitting Piping port Note 3) 10 9 D side Description/Model VCC12-00 Pilot port piping size ∗ Fill in the symbol for stainless steel fittings. For others, mark necessary items with a circle. Part number (Mountable valve number) 2 port valve (Sliding type) To fill in the blanks in the manifold number, please refer to the symbols in the catalogue. Select the valve referring to the specification table. - V V The upper table is for 2 Specification port valves. The lowerSheet is for 3 port valves. Unit Specify when the gate valve is necessary for cleaning the valve. This example requires one gate valve and four cleaning valves, but specify “06” as the number of valves that can be installed, as this must be an even number. When twenty-four (24) 3 port valves are used, specify “24”. nifold Manifold 2 port valve Valve options IN port OUT port Pilot port Seven (7) 2 port valves are installed. Since two valves are installed per manifold base, it must be an even number, so the number of the valve that can be installed is “08”. ∗ Specify four (4) stations for ma- Put “M”, because 2 port valves (including a cleaning unit) and 3 port valves are installed together. Fitting arrangement ø10 x ø8 (40° swivel elbow) ø12 x ø9 (40° swivel elbow) ø6 x ø5 (Male connector) 3 port valve (Sliding type) VCC13-00 Blanking plug for 3 port valve VVCC13-10A-1 Piping port IN port Piping port RETURN port U side (OUT port side) Cleaning unit IN port IN port RETURN port 02 04 06 08 10 12 14 16 18 20 40 Although six gate valves or cleaning 1 2 3 4 5 6 7 8 9 10 1112 1314 1516 1718 1920 valves can be installed, if you need only five valves, D side select the blanking plug. The plug is connected to the port with the blanking plug. 39 40 U side (OUT port side) Condition Manifold Specifications — Example of how to fill in Select stainless steel fitting for IN, RETURN port from the table below, and enter the symbol into the specification table. Symbol A B C D E Description For piping ø12 x ø9 40° swivel elbow For piping ø10 x ø8 40° swivel elbow For piping ø10 x ø7.5 40° swivel elbow For piping ø8 x ø6 40° swivel elbow For piping ø6 x ø4 40° swivel elbow Part no. Symbol F G H J K VCKK1209-02F VCKK1008-02F VCKK1075-02F VCKK0806-02F VCKK0604-02F Description For piping ø12 x ø9 Male connector For piping ø10 x ø8 Male connector For piping ø10 x ø7.5 Male connector For piping ø8 x ø6 Male connector For piping ø6 x ø4 Male connector Part no. VCKH1209-02F VCKH1008-02F VCKH1075-02F VCKH0806-02F VCKH0604-02F Fill in the model number in the table below for connecting the fitting to the OUT port. (See SUS316L stainless steel fitting type.) For connecting the elbow union, the piping direction is on top (IN, RETURN port side). OUT port Stainless steel fitting V C K -0 2 F It must be specified when the fitting is to the Note 1) Two valves can be installed per manifold block. Assign two valves in one square. connected Note 2) Please order a cleaning unit when the gate valve is necessary. Note 3) When the fitting is necessary for the IN, RETURN port, please order by selecting the necessary stainless steel fitting symbol in the port of each station. OUT port. For 40° swivel elbow, piping direction is on D side. Serial No. Customer/SMC use Customer code Department code Date of delivery U/C Fill in for faxed order Customer’s order no. Code for person in charge Registered image no. SMC order no. Component list Part no. Qty. Part no. Qty. Part no. 1 6 11 2 7 12 3 8 13 4 9 14 5 10 15 2 port valve is specified for the gate valve and the cleaning valve. 7 valves + 1 valve + 4 valves = 12 valves Back page 7 Qty. 24 EUROPEAN SUBSIDIARIES: Austria SMC Pneumatik GmbH (Austria). Girakstrasse 8, A-2100 Korneuburg Phone: +43 2262-62280, Fax: +43 2262-62285 E-mail: office@smc.at http://www.smc.at France SMC Pneumatique, S.A. 1, Boulevard de Strasbourg, Parc Gustave Eiffel Bussy Saint Georges F-77607 Marne La Vallee Cedex 3 Phone: +33 (0)1-6476 1000, Fax: +33 (0)1-6476 1010 E-mail: contact@smc-france.fr http://www.smc-france.fr Netherlands SMC Pneumatics BV De Ruyterkade 120, NL-1011 AB Amsterdam Phone: +31 (0)20-5318888, Fax: +31 (0)20-5318880 E-mail: info@smcpneumatics.nl http://www.smcpneumatics.nl Spain SMC España, S.A. Zuazobidea 14, 01015 Vitoria Phone: +34 945-184 100, Fax: +34 945-184 124 E-mail: post@smc.smces.es http://www.smces.es Belgium SMC Pneumatics N.V./S.A. Nijverheidsstraat 20, B-2160 Wommelgem Phone: +32 (0)3-355-1464, Fax: +32 (0)3-355-1466 E-mail: post@smcpneumatics.be http://www.smcpneumatics.be Germany SMC Pneumatik GmbH Boschring 13-15, D-63329 Egelsbach Phone: +49 (0)6103-4020, Fax: +49 (0)6103-402139 E-mail: info@smc-pneumatik.de http://www.smc-pneumatik.de Norway SMC Pneumatics Norway A/S Vollsveien 13 C, Granfos Næringspark N-1366 Lysaker Tel: +47 67 12 90 20, Fax: +47 67 12 90 21 E-mail: post@smc-norge.no http://www.smc-norge.no Sweden SMC Pneumatics Sweden AB Ekhagsvägen 29-31, S-141 71 Huddinge Phone: +46 (0)8-603 12 00, Fax: +46 (0)8-603 12 90 E-mail: post@smcpneumatics.se http://www.smc.nu Bulgaria SMC Industrial Automation Bulgaria EOOD 16 kliment Ohridski Blvd., fl.13 BG-1756 Sofia Phone:+359 2 9744492, Fax:+359 2 9744519 E-mail: office@smc.bg http://www.smc.bg Greece SMC Hellas EPE Anagenniseos 7-9 - P.C. 14342. N. Philadelphia, Athens Phone: +30-210-2717265, Fax: +30-210-2717766 E-mail: sales@smchellas.gr http://www.smchellas.gr Poland SMC Industrial Automation Polska Sp.z.o.o. ul. Poloneza 89, PL-02-826 Warszawa, Phone: +48 22 211 9600, Fax: +48 22 211 9617 E-mail: office@smc.pl http://www.smc.pl Switzerland SMC Pneumatik AG Dorfstrasse 7, CH-8484 Weisslingen Phone: +41 (0)52-396-3131, Fax: +41 (0)52-396-3191 E-mail: info@smc.ch http://www.smc.ch Croatia SMC Industrijska automatika d.o.o. Crnomerec 12, 10000 ZAGREB Phone: +385 1 377 66 74, Fax: +385 1 377 66 74 E-mail: office@smc.hr http://www.smc.hr Hungary SMC Hungary Ipari Automatizálási Kft. Budafoki ut 107-113, H-1117 Budapest Phone: +36 1 371 1343, Fax: +36 1 371 1344 E-mail: office@smc.hu http://www.smc.hu Portugal SMC Sucursal Portugal, S.A. Rua de Engº Ferreira Dias 452, 4100-246 Porto Phone: +351 22-610-89-22, Fax: +351 22-610-89-36 E-mail: postpt@smc.smces.es http://www.smces.es Turkey Entek Pnömatik San. ve Tic. A*. Perpa Ticaret Merkezi B Blok Kat:11 No: 1625, TR-34386, Okmeydani, Istanbul Phone: +90 (0)212-444-0762, Fax: +90 (0)212-221-1519 E-mail: smc@entek.com.tr http://www.entek.com.tr Czech Republic SMC Industrial Automation CZ s.r.o. Hudcova 78a, CZ-61200 Brno Phone: +420 5 414 24611, Fax: +420 5 412 18034 E-mail: office@smc.cz http://www.smc.cz Ireland SMC Pneumatics (Ireland) Ltd. 2002 Citywest Business Campus, Naas Road, Saggart, Co. Dublin Phone: +353 (0)1-403 9000, Fax: +353 (0)1-464-0500 E-mail: sales@smcpneumatics.ie http://www.smcpneumatics.ie Romania SMC Romania srl Str Frunzei 29, Sector 2, Bucharest Phone: +40 213205111, Fax: +40 213261489 E-mail: smcromania@smcromania.ro http://www.smcromania.ro UK SMC Pneumatics (UK) Ltd Vincent Avenue, Crownhill, Milton Keynes, MK8 0AN Phone: +44 (0)800 1382930 Fax: +44 (0)1908-555064 E-mail: sales@smcpneumatics.co.uk http://www.smcpneumatics.co.uk Denmark SMC Pneumatik A/S Knudsminde 4B, DK-8300 Odder Phone: +45 70252900, Fax: +45 70252901 E-mail: smc@smc-pneumatik.dk http://www.smcdk.com Italy SMC Italia S.p.A Via Garibaldi 62, I-20061Carugate, (Milano) Phone: +39 (0)2-92711, Fax: +39 (0)2-9271365 E-mail: mailbox@smcitalia.it http://www.smcitalia.it Russia SMC Pneumatik LLC. 4B Sverdlovskaja nab, St. Petersburg 195009 Phone.:+7 812 718 5445, Fax:+7 812 718 5449 E-mail: info@smc-pneumatik.ru http://www.smc-pneumatik.ru Estonia SMC Pneumatics Estonia OÜ Laki 12, 106 21 Tallinn Phone: +372 6510370, Fax: +372 65110371 E-mail: smc@smcpneumatics.ee http://www.smcpneumatics.ee Latvia SMC Pneumatics Latvia SIA Smerla 1-705, Riga LV-1006 Phone: +371 781-77-00, Fax: +371 781-77-01 E-mail: info@smclv.lv http://www.smclv.lv Slovakia SMC Priemyselná Automatizáciá, s.r.o. Námestie Matina Benku 10, SK-81107 Bratislava Phone: +421 2 444 56725, Fax: +421 2 444 56028 E-mail: office@smc.sk http://www.smc.sk Finland SMC Pneumatics Finland Oy PL72, Tiistinniityntie 4, SF-02231 ESPOO Phone: +358 207 513513, Fax: +358 207 513595 E-mail: smcfi@smc.fi http://www.smc.fi Lithuania SMC Pneumatics Lietuva, UAB Oslo g.1, LT-04123 Vilnius Phone: +370 5 264 81 26, Fax: +370 5 264 81 26 Slovenia SMC industrijska Avtomatika d.o.o. Mirnska cesta 7, SLO-8210 Trebnje Phone: +386 7 3885412 Fax: +386 7 3885435 E-mail: office@smc.si http://www.smc.si © DiskArt™ 1988 © DiskArt™ OTHER SUBSIDIARIES WORLDWIDE: ARGENTINA, AUSTRALIA, BOLIVIA, BRASIL, CANADA, CHILE, CHINA, HONG KONG, INDIA, INDONESIA, MALAYSIA, MEXICO, NEW ZEALAND, PHILIPPINES, SINGAPORE, SOUTH KOREA, TAIWAN, THAILAND, USA, VENEZUELA http://www.smc.eu http://www.smcworld.com SMC CORPORATION Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 FAX: 03-5298-5362 1st printing MO printing MO 00 Printed in Spain Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.