Ametek Rotron Regenerative Blower

advertisement
Ametek Rotron Regenerative Blower
Model EN858BD72WL
This environmental EN blower is designed the same as the DR blowers, except added features include: heavy
duty cast aluminum manifold, spark resistant housing cover, impeller, muffler tower and manifold are vacuum
impregnated, Teflon® lip seal in a stainless steel case standard for leakage containment to 25 cc/min or less,
explosion-proof motors standard and available in a variety of world voltages, all metal-to-metal surfaces are
sealed with RTV sealant, and various UL explosion-proof listings. Consult factory. Environmental (EN)
regenerative blowers are also available in our Chemical Processing (CP) configuration: Chem-Tough(TM)
surface conversion corrosion resistant treatment for all castings, Teflon® lip seal in a stainless steel case
standard for leakage containment to 25 cc/min or less, stainless steel hardware throughout, and nickel plated
flanges and muffler retainers.
Contact us for a price on this refurbished industrial blower.
363 W. SOUTH AIRPORT ROAD - TRAVERSE CITY, MI 49686 - BUS: (231) 264-3000 - FAX: (231) 264-3001
6140 RASHELLE DRIVE, SUITE 1 - FLINT, MI 48507 - BUS: (810) 238-9190 - FAX: (810) 238-9195
7082 GRANGE HALL ROAD - HOLLY, MI 48442 - BUS: (800) 423-2043
www.global-treatmentsolutions.com
SectionC 2004.qxd
6/26/04
10:53 AM
Page C-25
ROTRON  Regenerative Blowers
EN 858 & CP 858
Sealed Regenerative Blower w/Explosion-Proof Motor
FEATURES
•
•
•
•
•
•
Manufactured in the USA – ISO 9001 compliant
Maximum flow: 400 SCFM
Maximum pressure: 120 IWG
Maximum vacuum: 98 IWG
Standard motor: 10 HP, explosion-proof
Cast aluminum blower housing, cover, impeller &
manifold; cast iron flanges (threaded); teflon lip seal
• UL & CSA approved motor with permanently
sealed ball bearings for explosive gas
atmospheres Class I Group D minimum
• Sealed blower assembly
• Quiet operation within OSHA standards
MOTOR OPTIONS
• International voltage & frequency (Hz)
• Chemical duty, high efficiency, inverter duty
or industry-specific designs
• Various horsepowers for application-specific needs
BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models
• Slip-on or face flanges for application-specific needs
ACCESSORIES (See Catalog Accessory Section)
•
•
•
•
•
•
•
Flowmeters reading in SCFM
Filters & moisture separators
Pressure gauges, vacuum gauges & relief valves
Switches – air flow, pressure, vacuum or temperature
External mufflers for additional silencing
Air knives (used on blow-off applications)
Variable frequency drive package
BLOWER PERFORMANCE AT STANDARD CONDITIONS
AIR FLOW RATE (M3/MIN)
AIR FLOW RATE (M3/MIN)
10.0
12.0
14.0
2.0
▲B
▲B
8
200
60 Hz
60
150
50 Hz
40
100
1.0
12.0
14.0
▲-MAX SUCTION
POINT
A-10 HP B-7.5 HP
A, B
▲
-100
300
250
A, B
▲
-80
200
60 Hz
-60
150
50 Hz
-40
100
-20
100
200
300
400
500
80
40
0
12,000
9,000
6,000
400
500
40
0
12,000
9,000
6,000
3,000
150
0
300
80
150
50
200
120
3,000
100
100
AIR FLOW RATE (SCFM)
MOTOR
POWER
WINDING
INPUT
WATTS TEMP RISE °C
120
50
0
AIR FLOW RATE (SCFM)
BLOWER
AIR TEMP
RISE °C
MOTOR
WINDING
TEMP RISE °C
POWER
INPUT
WATTS
BLOWER
AIR TEMP
RISE °C
4
50
0
C-25
6
10.0
2
20
Rev. 2/04
8.0
-120
250
80
6.0
SUCTION
300
INCHES OF MERCURY
A
▲
100
▲-MAX PRESSURE
POINT
A-10 HP B-7.5 HP
4.0
-140
10
mBAR
PSIG
INCHES OF WATER
4.0
2.0
8.0
PRESSURE
▲A
120
3.0
6.0
mBAR
4.0
INCHES OF WATER
2.0
140
5.0
100
50
0
AMETEK Technical and Industrial Products, Kent, OH 44240 • e mail: rotronindustrial@ametek.com • internet: www.ametektmd.com
SectionC 2004.qxd
6/26/04
10:53 AM
Page C-26
ROTRON  Regenerative Blowers
EN 858 & CP 858
Sealed Regenerative Blower w/Explosion-Proof Motor
Scale CAD drawing available upon request.
IN
MM
TOLERANCES: .XX ±
DIMENSIONS:
.1
2.5
(UNLESS OTHERWISE NOTED)
A
0.75" NPT CONDUIT CONNECTION AT 12 O’CLOCK POSITION
SPECIFICATIONS
MODEL
Part No.
Motor Enclosure – Shaft Material
Horsepower
Phase – Frequency 1
Voltage 1
Motor Nameplate Amps
Max. Blower Amps 3
Inrush Amps
Starter Size
Service Factor
Thermal Protection 2
XP Motor Class – Group
Shipping Weight
1
2
3
EN858BD72WL
038744
Explosion-proof – CS
10.0
Three - 60 Hz
230
460
24
12
24
12
162
81
2
1
1.0
Class B - Pilot Duty
I-D, II-F&G
332 lb (151 kg)
EN858BD86WL
038745
Explosion-proof – CS
10.0
Three - 60 Hz
575
9.6
11.6
93
1
1.0
Class B - Pilot Duty
I-D, II-F&G
332 lb (151 kg)
EN858BA72WL
080070
Explosion-proof – CS
7.5
Three - 60 Hz
230
460
17
8.5
26
13
126
63
1
1
1.0
Class B - Pilot Duty
I-D, II-F&G
320 lb (145 kg)
CP858FZ72WLR
038980
Chem XP – SS
Same as
EN858BD72WL –
038744
except add
Chemical Processing
(CP)
features
from
catalog
inside front cover
Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are
factory tested and certified to operate on both: 208-230 /415-460 VAC- 3 ph- 60 Hz and 190-208/380-415 VAC- 3 ph- 50 Hz. Our dual
voltage 1 phase motors are factory tested and certified to operate on both: 104-115 / 208-230 VAC-1 ph- 60 Hz and 100-110 /200-220
VAC-1 ph- 50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside our
certified range.
Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors
or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature).
Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or
ambient temperatures above 40°C.
Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or
ambient temperature reaches the maximum operating temperature.
Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates.
AMETEK Technical and Industrial Products, Kent, OH 44240 • e mail: rotronindustrial@ametek.com • internet: www.ametektmd.com
Rev. 2/04
C-26
Environmental / Chemical Processing Blowers
EN 858 & CP 858
7.5 / 10.0 HP Sealed Regenerative w/Explosion-Proof Motor
18.60
472.4
L
23.34
592.8
6.92
175.8
2 1/2" NPSC
FEMALE THREAD
BOTH PORTS
15.48
393.2
13.53
343.7
7.09
180.1
1.91
48.5
ROTATION DIRECTION
IN
10.50
266.7
18.95
481.3
21.81
554.0
24.5
622.3
8.17
207.5
OUT
NOTE 1
IN
MM
10.75
273.1
13.00
330.2
9.50
241.3
6.75
171.4
1.75
44.5
8.21
208.5
9.46
240.3
10.96
278.4
NOTES
1 TERMINAL BOX CONNECTOR HOLE 3/4” NPT.
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.
MODEL
EN858BA72WL
EN858BD72WL
L (IN/MM)
23.65/600.7
26.00/660.4
Part/ Model Number
EN858BD72WL
Specification
Units
Motor Enclosure - Shaft Mtl.
Horsepower
Phase - Frequency
Voltage
AC
Motor Nameplate Amps
Amps (A)
Max. Blower Amps
Amps (A)
Inrush Amps
Amps (A)
Service Factor
Starter Size
Thermal Protection
XP Motor Class - Group
Lbs
Shipping Weight
Kg
EN858BD86WL
EN858BA72WL
CP858FZ72WLR
038744
038745
080070
038980
Explosion-proof-CS
10.0
Three-60 hz
230/460
24/12
30/15
234/117
1.0
2/1
Class B - Pilot Duty
I-D, II-F&G
338
153.3
Explosion-proof-CS
10.0
Three-60 hz
575
9.6
11.6
93
1.0
1
Class B - Pilot Duty
I-D, II-F&G
338
153.3
Explosion-proof-CS
7.5
Three-60 hz
230/460
18.6/9.3
26/13
126/63
1.0
1/1
Class B - Pilot Duty
I-D, II-F&G
326
147.9
Chem XP-SS
10.0
Three-60 hz
230/460
24/12
30/15
234/117
1.0
2/1
Class B - Pilot Duty
I-D, II-F&G
338
153.3
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.
Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.
XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258
Customer Service Fax: +1 215.256.1338
www.ametektip.com
D 27
____
Environmental / Chemical Processing Blowers
EN 858 & CP 858
7.5 / 10.0 HP Sealed Regenerative w/Explosion-Proof Motor
FEATURES
•
•
•
•
•
•
Manufactured in the USA - ISO 9001 and NAFTA compliant
Maximum pressure: 120 IWG
Maximum vacuum: 95 IWG
Standard motor: 10 HP, explosion-proof
Cast aluminum blower housing, impeller , cover & manifold; cast iron
• UL & CSA approved motor with permanently sealed ball bearings for
explosive gas atmospheres Class I Group D minimum
• Sealed blower assembly
• Quiet operation within OSHA standards
MOTOR OPTIONS
• International voltage & frequency (Hz)
BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models
ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves
•
•
• Variable frequency drive package
Blower Performance at Standard Conditions
136
204
Air Flow Rate - m3/hour
272 340 408 476
612
680
748
Legend
Pressure:
Suction:
EN858D72WL
EN858A72WL
100
Inches of Water
544
80
300
250
100
200
80
60
150
40
100
20
0
0
40
80
120
160
200
240
280
320
360
400
440
120
Inches of Water
68
mbar
120
0
50 Hz
0
Temperature curves are based on standard model
Air Flow Rate - m3/hour
272 340 408 476
544
612
680
748
Legend
Pressure:
Suction:
EN858D72WL
EN858A72WL
300
250
200
100
50
20
50
0
0
0
40
80
120
160
200
240
280
320
360
400
440
0
Air Flow Rate - SCFM
100
50
0
Temperature curves are based on standard model
100
Blower Air
Temp Rise °C
Blower Air
Temp Rise °C
0
204
40
100
50
136
150
Motor Winding
Temp Rise °C
Motor Winding
Temp Rise °C
50
68
60
Air Flow Rate - SCFM
100
0
mbar
60 Hz
50
0
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258
Customer Service Fax: +1 215.256.1338
www.ametektip.com
D 28
____
Download