DOOR CONTROLLERS type a dead man controller Supplied as standard with all electric doors and grills, unless another type specified. Comprises a box containing UP and DOWN contactors, terminals for supply, motor and limit switch. UP and DOWN buttons on box drive door as long as button pressed – door will stop when you take finger off button (“dead Man control”) or when door hits limit. CODE DESCRIPTION DC-1A Push to run, 1 phase type A controller with UP-DOWN contactors and push buttons, in IP65 enclosure. DC-3A Push to run, 3 phase type A controller, with UP-DOWN contactors and push buttons, in IP65 enclosure. DC-VSD Push to run, VSD type A controller with UP-Down push buttons and integral VSD for single phase supply and 3 phase motor, soft start and stop and variable speed. type m maintained controller Similar to Type A, but when UP button pressed, door will go all the way up, until stopped by up limit. (“Maintained”) DOWN button operates same as Type A, ie. “dead man” CODE DESCRIPTION DC-1M Single Phase. Maintained UP, Push to Run DOWN, 3 phase type M Controller, with contactors, overload and UP-STOP-DOWN push buttons, in IP65 enclosure DC-3M Maintained, 3 phase type M controller, with contactors, overload and UP-STOP-DOWN push buttons, in IP65 enclosure. radio remote controllers CODE DESCRIPTION RR3 Single Phase or 3 Phase. Complete stand alone, multi-mode Automatic Controller, single or 3 phase, with UP-DOWN contactors and overload relay, UP-DOWN button, Modes are Toggle (Radio Remote), Auto Close and Security Close. Beam and radio controls are extra RR3 kit Single Phase or 3 Phase. Complete stand alone, multi-mode Radio Remote Controller, single or 3 phase, with UP-DOWN contactors and overload relay, UP-DOWN button, and LRX-1E radio receiver and 1 – LTX-1 Remote Beam is extra Modes are Toggle (Radio Remote), Auto Close and Security Close CODE DESCRIPTION RRI1 Single Phase or 3 Phase. Radio Remote Interface for retrofit to local starter, motor set or tube motor. RR1 kit Single Phase or 3 Phase. Radio Remote Interface kit for retrofit to local starter, motor set or tube motor, comprising RRI-1 unit, LRX-1E Receiver and 1 – LTX-1 Remote Beam is extra. Toggle mode only auto logic controllers Used on Car Parks, Hospitals, Fire Stations, Police, Courts, Prisons, Apartment and Office Blocks and any site where logic control and interface with security or building management system is required. CODE DESCRIPTION AL2-3P Complete stand alone, full featured, multi-mode, automatic door controller for 3 phase motor. In IP65 enclosure with pad-lockable isolator, contactors, electronic overload relay, multi-mode logic board, with mode switch and adjustable timers. Modes are toggle (radio remote), auto close and security close. The multi mode feature enables mode to be changed after installation. For example, if the tenant/owner wants to change from toggle (UP-Down) mode to auto close, it only involves changing the dip switch on PCB (printed circuit board). Timers have screwdriver adjustment. No programming required. Security close mode is new - door closes immediately after vehicle passes beam - stops “tailing” and improves security. Over run timer - to stop door if limits do not operate. Auto/manual key switch enables easy setting of limits and facilitates service. UP-DOWN limit switch and beam status contacts are provided. With security and building management system inputs. AL2-VSD Complete stand alone, full featured, multi-mode, automatic door controller with integral VSD for single phase supply and 3 phase motor, soft start and stop and variable speed. In IP65 enclosure with pad-lockable isolator, contactors, multi-mode logic board, with mode switch and adjustable timers. Modes are toggle (radio remote), auto close and security close. With security and building management system inputs. radio remote controllers This is the latest version of “Radio Remote Controller” but now features: • Multi‐mode – Toggle, Auto Close and Security Close selected by switch on PCB. • Screwdriver set timers ‐ No programming required! • Over Run timer – Auto or Manual ‐ set to stop door if limits do not operate. • Electronic overload relay – adjustable from 0.5 to 6.5 Amps. • The multi Mode feature enables Mode to be changed after installation, for example, if the tenant/owner wants to change from toggle (UP/DOWN) mode to Auto Close, it only involves changing the dip switch on PCB (printed circuit board) • Both Auto Close and Manual Run timers adjusted by screwdriver – no programming required! • Security Close feature is new – door closes immediately after vehicle passes beam – stops “tailgating” and improves security. • Remotes and Accessory connections are extra low voltage 24VAC. RR‐3 is not a low cost alternative to AL‐2 It does not have inputs for security and building management systems, and does not have lockable isolator, manual mode or variable speed control. RR‐3 is a good low cost option for “stand alone” doors on factories, houses, and multiple storage facilities etc and control can be by radio remote, prox, swipe card, ground loop and push button. Fitting of beam is recommended. ACCESSORIES safety beam CODE DESCRIPTION SB3 Safety Beam The SB-3 is used as a safety device when fitted in conjunction with garage doors, rolling doors, sliding gates, swinging gates and parking barriers. It has a through beam photo cell with separate transmitter and a 10m range receiver, IP66 weatherproof. Power Supply 12-24v AC/DC, Relay contacts 5A 30V AC/DC. remote receivers and transmitters CODE DESCRIPTION LRX-1E 1 Channel receiver with antenna Complete with an industrial type antenna and pre-fitted “F” connector for flexible mounting systems these industrial/commercial receivers utilize a 1024 code. Code system that integrates perfectly with our full line transmitters. LTX-1 1 Button key chain transmitter Complete with LED to show the strength of your 12 volt alkaline battery, this portable transmitter offers 1, 024 codes and operates at full distance range. It’s handsome neutral coloured, fine grained finished case and moulded in hole to accept your key ring or chain will add to the ease of using this key chain transmitter. LTX-2 2 Button key chain transmitter With all the capabilities of the 1 button model, the two button model offers you the capability of operating either your gate and garage door, or 2 separate garage doors with one transmitter. This model also offers 1024 codes on each of the channels to insure your security. LTX-1V 1 Button Visor Transmitter One button, one channel 9 volt battery powered transmitter, with removable visor clip. 1024 codes. LTX-2V 2 Button visor transmitter Two button, two channel 9 volt battery powered transmitter, with removable visor clip. 1024 codes on each channel. LTX-3V 3 Button visor transmitter Three button, three channel 9 volt battery powered transmitter, with removable visor clip. 1024 codes on each channel. LRX-C5 Coaxial cable To be used in conjunction with LRX-1E. This is a 5 meter length of coaxial cable, with “F” type fittings both ends. The mounting bracket is 130mm long with a 63mm outward extension. This allows for the antenna to be mounted higher in the air or closer to the opening. key switches CODE DESCRIPTION KS-HDF Heavy Duty, stainless steel plate and enclosure. 6 pin Lockwood 5 profile, with random key, and can be fitted with most types of security cylinder, and master keyed. Light Duty all have same key no, and cannot be changed. Flush Plate UP-DOWN. CODE DESCRIPTION KS-HD Heavy Duty, stainless steel plate and enclosure. 6 pin Lockwood 5 profile, with random key, and can be fitted with most types of security cylinder, and master keyed. Light Duty all have same key no, and cannot be changed. Enclosed UP DOWN CODE DESCRIPTION KS-LD Heavy Duty, stainless steel plate and enclosure. 6 pin Lockwood 5 profile, with random key, and can be fitted with most types of security cylinder, and master keyed. Light Duty all have same key no, and cannot be changed. Light Duty UP DOWN enclosed. UNIVERSAL LOOP DETECTOR The only loop detector you’ll ever need. CODE DESCRIPTION 00-DSP-10 Loop Detector DSP-10 ”Universal” 10-30V AC/DC features Loop Size - Works on any in-ground inductive loop from 20 to Indicators - Separate Power/Fail and Detect LEDs. 1000 uH. small plastic case. Fail Safe or Fail Secure Operation - Can be easily changed to Hold time - Normal or extended hold time is selectable. either mode in the field. Power Brownout Call Memory – Power interruptions of short duration are ignored. If power fails for approximately three seconds or less the DSP-10 “remembers” a vehicle. Intelligent Power Protection – A DSP-10-LV is protected from damage if plugged into a higher voltage. No need to change a fuse or reset a circuit breaker, simply plug the detector into the proper voltage and it works. Compact Size - Industry standard 11 pin connector in a Loop failure - If the loop fails (opens or shorts) the power indicator flashes. Output B can also indicate this condition if desired (see above). The option to “remember” an intermittent loop failure is also provided. Delay - Can be selected to ignore fast moving vehicles over the loop. Extension - Extends a call for slow moving vehicles. front panel selectable switches Sensitivity - Ten sensitivity settings. Frequency - Automatically tunes within one of four operating ranges. Outputs - Two separate relay outputs with features that are front panel programmable as follows: Sensitivity Boost - Can be used in special applications to insure complete detection of high-bed vehicles. Output A - Main detection output. Can be modified by delay and extension. Factory set to be fail safe. Fail mode operation is easily changeable by internal jumpers. Output B - Can be set to one of the following: 1) True presence (no extension or delay) 2) Pulse on vehicle entering loop 3) Pulse on vehicle exiting loop 4) Loop Fail output OPERATION The DSP-10 vehicle detector has been specifically designed to handle all parking, drive-through and access control applications, working on virtually any size loop, the DSP-10 automatically tunes itself to the best operating frequency. Environmental conditions are constantly compensated with the DSP-10’s HYPERTRACK software. The DSP-10’s inherent noise filtering algorithms allow it to work reliably in any electrical situation, and it can be used as either a safety loop or free exit loop detector. With the flexibility to be either “fail safe” or “fail secure,” it is the only parking detector you will ever need. The DSP-10 is available in two voltage ranges: DSP-10-LV 10 to 30 Volts, AC or DC DSP-10-230 230 Volts AC With its compact size, front panel switch features, and built-in flexibility the DSP-10 is the most “user friendly” detector on the market today. dsp-10 instructions and specifications Delay - With DIPSWITCH 1 turned off there is no delay. With DIPSWITCH 1 turned on there is a 2 second delay before output A occurs. This 2 second delay is “flashed” on the CALL LED. If the vehicle leaves before the two seconds has timed out, the output will not occur. Delay only affects Output A. Extension - DIPSWITCHES 2 and 3 are used to select extension timing. See chart below for extension times. Extension allows a vehicle to be “remembered” for a period of time after the vehicle has left the loop. Selected extension time is flashed on the call LED. Extension timing only affects Output A. DIP Switch 2 DIP Switch 3 0 seconds Off Off 2 seconds On Off 5 seconds Off On 10 seconds On On Sensitivity Boost - DIPSWITCH 4 selects this feature. With switch 4 turned on, sensitivity is automatically boosted during a call to improve detection of high-bed vehicles and truck/trailer combinations. Sensitivity boost is not applicable to most situations. Output B Function Select - DIPSWITCHES 5 and 6 determine the function of the second output relay, Output B. See chart below to select a specific function. This output can be used in any one of the following ways: True presence - The relay is energized whenever a vehicle is present. The relay is not affected by any delay or extension timing. Entry pulse - The relay is energized for 250 mS when a vehicle enters the loop, or after the delay interval, if programmed. Exit pulse - The relay is energized for 250 mS when a vehicle exits the loop or after the extension time, if programmed. Loop fail - If the inductive loop fails (opens or shorts), the output B relay energizes. DIP Switch 5 DIP Switch 6 True Presence Off Off Entry Pulse On Off Exit Pulse Off On Loop Fail On On Presence - DIPSWITCH 7 is normally left in the off position. If extended presence is required, this switch is turned on. This feature is only used in those rare cases when a vehicle will be over the loop for a long time (loading dock, etc.). Sensitivity - Experience has shown that almost all parking and access control applications can be handled with sensitivity set at NORMAL (level 5). The rotary sensitivity switch is rarely moved from NORMAL. However, the DSP-10 has ten sensitivity settings varying from LOW (level 0) to HIGH (level 9). Loop Failure Memory - With DIPSWITCH 8 turned on, the DSP-10 will indicate a prior intermittent loop failure. Frequency - One of four operating frequencies can be selected by using front panel DIPSWITCHES 9 and 10. DIP Switch 9 DIP Switch 10 High Off Off Medium High On Off Medium Low Off On Low On On Fail Safe Operation (Factory Default) - In fail safe mode the output A relay is energized and will de-energize for any one of the following conditions: vehicle detection, loop failure, or power failure. In this mode, continuity will occur between connector pins 5 and 10 whenever a vehicle is detected. Fail Secure Operation - In fail secure mode the output A relay is de-energized and will energize for either vehicle detection or loop failure. In this mode, continuity will occur between connector pins 5 and 6 whenever a vehicle is detected. NOTE - Changing any DIPSWITCH or ROTARY SWITCH setting automatically resets the detector. Indicators - The green POWER LED shows the following status: Normal On Loop open 1 flash/second Loop shorted 2 flashes/second Intermittent loop 3 flashes/second The red DETECT LED shows the following status: Delay Blinks slowly Call On Extension Blinks fast No Detect Off Output Relay Ratings - 3A, 150 VDC or 300 VAC. Power - DSP-10-LV (10 to 30 Volts AC or DC), DSP-10-117 (117 Volts AC) and DSP-10-230 (230 VAC). Power consumption less than 3 Watts (all models). Enclosure - Impact resistant, high temperature plastic. H - 2.375” (60mm) W - 1.75” (45mm) D - 3.61” (92mm) Connector - Amphenol 11-pin connector: 1 (Black) - AC hot / DC + 2 (White) - AC neutral / DC COM 3 (Orange) - B relay (Closes for detect) 4 (Green) - Chassis ground 5 (Yellow) - A relay COM 6 (Blue) - A relay (Closes for detect) 7 (Gray) - Loop 8 (Brown) - Loop 9 (Red) - B relay Common 10 (Pink) or (White/Black) - A relay (Opens for detect) 11 (Violet) or (White/Red) - B relay (Opens for detect) Operating Temperature - -35°F to 165°F (-37°C to 74°C). integrated operators Integrated Operators with Motor Controller and Limit Switches fitted with pre-wired pendant button (6M cord). All operators are rated for High Cycle duty. Power Cord for “PLUG AND PLAY” installation. Except – N models CODE DESCRIPTION LT-037-1P-DC-1A 0.37KW 0.5HP 240VAC 50Hz. Shaft Output: 80Nm, 28RPM, 85mm dia Operation: Press to Run UP/DOWN LT-037-1P-RR3 0.37KW 0.5HP 240VAC 50Hz. Shaft Output: 80Nm. 28RPM. 85mm dia Operation: Complete Stand alone Multi mode automatic controller. Toggle, Auto Close or Security Close Integrated Operators with Motor Controller and Limit Switches fitted with pre-wired pendant button (6M cord). All operators are rated for High Cycle duty. Power Cord for “PLUG AND PLAY” LT-075-1P-DC-1A 0.75KW 1.0HP 240VAC 50Hz. Shaft Output: 160Nm, 28RPM, 95mm dia Operation: Press to Run UP/DOWN LT-075-1P-RR3 0.75KW 1.0HP 240VAC 50Hz. Shaft Output: 160Nm. 28RPM. 95mm dia Operation: Complete Stand alone Multi mode automatic controller. Toggle, Auto Close or Security Close Integrated Operators with Motor Controller and Limit Switches fitted with pre-wired pendant button (6M cord). All operators are rated for High Cycle duty. Requires three phase power supply only to be connected at installation LT-037-3P-DC-3A 0.37KW 0.5HP 415VAC 50Hz. Shaft Output: 80Nm, 28RPM, 85mm dia Operation: Press to Run UP/DOWN LT-037-3P-RR3 0.37KW 0.5HP 415VAC 50Hz. Shaft Output: 80Nm. 28RPM. 85mm dia Operation: Complete Stand alone Multi mode automatic controller. Toggle, Auto Close or Security Close Integrated operators with motor controller and limit switches fitted with pre-wired pendant button (6m cord). All operators are rated for high cycle duty. Requires three phase power supply only to be connected at installation. LT-075-3P-DC-3A 0.75KW 1.0HP 415VAC 50Hz. Shaft Output: 160Nm, 28RPM, 85mm dia Operation: Press to Run UP/DOWN LT-075-3P-RR3 0.75KW 1.0HP 415VAC 50Hz. Shaft Output: 160Nm. 28RPM. 85mm dia Operation: Complete stand alone multi mode automatic controller. Toggle, auto close or security close Also available Integrated operators only, These operators are rated for high cycle duty. No motor controller fitted - Naked for connection to separate wall mounted controller. LT-037-1P-N 0.37KW 0.5HP 240VAC 50Hz. Shaft Output: 80Nm. 28RPM. 85mm dia Operation: Naked. LT-075-1P-N 0.75KW 1.0HP 240VAC 50Hz. Shaft Output: 160Nm. 28RPM. 85mm dia Operation: Naked electric motors CODE DESCRIPTION ML7124 Single Phase 230V 50Hz 0.37kW 0.5hp D71 B34 frame foot and face mounting. ML8024 Single Phase 230V 50Hz 0.75kW 1.0 hp D80 B34 frame foot and face mounting. RMS7124 3 Phase 400V star or 230V delta 50Hz 0.37kW 0.5hp D71 B34 foot and face mounting. RMS8024 3 Phase 400V star or 230V delta 50Hz 0.75kW 1.0hp D80 B34 foot and face mounting. electric gear boxes LEES TECH High Cycle Roller Shutter Operators feature a heavy duty industrial TEFC motor coupled to a cast aluminium gearbox. CODE DESCRIPTION 01-LT037-3P 40:1 3 phase 400V Operator, 0.37kW 3 phase HCR Operator 40:1 ratio 01-LT037-3P 50:1 3 phase 400V Operator, 0.37kW 3 phase HCR Operator 50:1 ratio. 01-LT075-3P 3 phase 400V Operator, 0.75kW 3 phase HCR Operator 01-LT110-3P 3 phase 400V Operator, 1.1kW 3 phase HCR Operator 01-LT150-3P 3 phase 400V Operator, 1.5Kw 3 phase HCR Operator 01-LT220-3P 3 phase 400V Operator, 2.2kW 3 phase HCR Operator 50:1 01-LT037-1P 40:1 1 phase 230V Operator, 0.37kW 1 phase HCR Operator 40:1 ratio. 01-LT037-1P 50:1 1 phase 230V Operator, 0.37kW 1 phase HCR Operator 50:1 ratio. 01-LT075-1P 1 phase 230V Operator, 0.75kW 1 phase HCR Operator rotary limit switch CODE DESCRIPTION RLS-1 RLS-1 comprises a stainless steel worm shaft operating 2 micro switches rated for control circuit up to 440VAC