TENDER DOCUMENT TENDER No.: BHI/PI(S)/675/1027 FOR Tender for Fabrication and Supply of “Chutes and Associated Works of CSP Area” for the project of “Augmentation of Fuel & Flux Crushing and Screening Facilities (Package No. – 064) for Bhilai Steel Plant, Bhilai at Chhattisgarh”. VOLUME – III Tender Specifications ENGINEERING PROJECTS (INDIA) LIMITED (A GOVT. OF INDIA ENTERPRISE) B-252, Street No. – 5, Smriti Nagar, Bhilai (Chhattisgarh) – 490020 TECHNICAL SPECIFICATION GENERAL The following Technical Specification shall be read in conjunction with General Technical Specification (GTS) of Bhilai Steel Plant, SAIL. If there are any provisions in this Technical Specification, which are at variance with the provisions of General Technical Specification (GTS) of Bhilai Steel Plant, SAIL and General Specification, the provisions in this Technical Specification/approved drawings shall take precedence. SCOPE OF SUPPLY The scope of the supply includes fabrication, painting (Two coats of Primer as per GS-09 of Vol-III), inspection at manufacturer’s works, packing, dispatch, transportation, delivery to site of “Chutes and Associated Works of CSP Area” for Conveyor Nos. K11-6, K116A, K11-6B, K11-9, K11-10, K11-10E, K11-11&12, K11-13&14, K11-15, K11-15A, K1116, K11-16A, K11-17, K11-18, K11-19&20, K11-21&22, KA-1, KA-2, KA-3, KA-4, KA-5, C3A-C2 as per specifications and scope defined in tender documents complete with all accessories. In addition to this, General Technical Specification of MECON may be referred for additional details. Bought out items shall be as per approved makes of MECON/BSP for Package 064. EPI – Bhilai Volume-2 Page 1 of 1 APPENDIX – 6 LIST OF APPROVED SUB-CONTRACTORS / VENDORS 1.0 I. The following Sub-Contractors / Vendors are approved for carrying out the item of the Facilities indicated against each of them. Where more than one SubContractor / Vendor is listed, the Contractor is free to choose between them, but it must notify the Employer of its choice well in advance time prior to appointing any selected Sub-Contractor / Vendor. In accordance with the Sub-Clause 19.1 of GCC, the Contractor is free to submit proposals for Sub-Contractors / Vendor for additional items from time to time. No Sub-Contractors / Vendors shall be placed with any such Sub-Contractors / Vendors for additional items until the SubContractors / Vendors have been approved in writing by the Employer and their name have been added to this list of approved Sub-Contractors / Vendors. HYDRAULIC EQUIPMENS AND SPARES SN SPARE / EQUIPMENT NAME OF THE PREFERRED/ REPUTED MANUFACTURES 1 1.1 COMPLETE HYDRAULIC SYSTEM COMPLETE HYDRAULIC SYSTEM WITH SERVO CONTROL 1.2 COMPLETE HYDRAULIC SYSTEM WITH PROPORTIONAL AND CONVENTIONAL CONTROLS 2 2.1 HYDRAULIC PUMPS AXIAL PISTON PUMPS 2.2 VANE PUMPS 2.3 REDIAL PISTON PUMPS 2.4 GEAR PUMPS 3 HYDRAULIC MOTOR 4 SERVO VALVES 5 PROPORTIONAL VALVES BOSCH REXROTH, EATON VICKERS, MOOG BOSCH REXROTH, EATON VICKERS, YUKEN, PARKER BOSCH REXROTH, EATON VICKERS, PARKER BOSCH REXROTH, EATON VICKERS, YUKEN, PARKER BOSCH REXROTH, EATON VICKERS, YUKEN, PARKER, L & T, HAWE BOSCH REXROTH, EATON VICKERS, YUKEN, PARKER BOSCH REXROTH, EATON VICKERS, PARKER, L & T, HAGLUNDS, DANFOSS MOOG, BOSCH REXROTH MOOG, BOSCH REXROTH EATON VICKERS Appendix-6 List of approved vendors. Page 1 of 32 YUKEN, PARKER 6 6.1 HYDRAULIC CONTROL VALVES DIRECTIONAL CONTROL VALVES 6.2 PRESSURE CONTROL VALVES 6.3 FLOW CONTROL VALVES 7 7.1 HYDRAULIC CYLINDERS CRITICAL APPLICATION AS PER DRAWING CYLINDERS AS PER CATALOGUE 7.2 GENERAL APPLICATION CYLINDERS AS PER DRAWING AS PER CATALOGUE 8 8.1 HYDRAULIC FILTERS FILTER FOR SYSTEMS HAVING SERVO AND PROPORTIONAL CONTROL VALVES 8.2 FILTER FOR SYSTEMS HAVING CONVENTIONAL CONTROL VALVES 9 9.1 SEALS SEALS FOR CRITICAL HYDRAULIC CYLINDERS ** 9.2 SEALS FOR GENERAL PURPOSE HYDRAULIC CYLINDERS IMPORTED INDIGENOUS BOSCH REXROTH, EATON VICKERS, YUKEN, PARKER BOSCH REXROTH, EATON VICKERS, YUKEN, PARKER BOSCH REXROTH, EATON VICKERS, YUKEN, PARKER WIPRO, OSCAR, USHA – TELEHOIST VEIJAN BOSCH REXROTH, EATON VICKERS, PARKER WIPRO, OSCAR, VEIJAN, IPH, SALZGITTER, USHA - TELEHOIST BOSCH REXROTH, EATON VICKERS, PARKER HYDAC, PALL, STAUFF HYDAC, PALL, STAUFF, EPE, PARKER HUNGER, PARKER, BUSAK – SHAMBAN, MERKEL HUNGER, PARKER, BUSAK – SHAMBAN, MERKEL SPAREAGE, OMCO, VAKO, SOFTEX, REECO Appendix-6 List of approved vendors. Page 2 of 32 MACHINED SEALS SEALJET, ANKSEALS BALL VALVES 10 STAUFF, PARKER, HYDAC ACCUMULATORS 11 HYDAC, EPE, FAWCET – CHRISTIE HYDRAULIC PIPE CLAMPS 12 HYD- AIR, STAUFF, PARKER, HYDAC BARE HOSES 13 SEA 100 DUNLOP – HIFLEX, R1/R2/R9/R10/R11/ AEROQUIP, R13, EN 853 1 ST MANULI, /ISN/2ST/2SN, EN GATES 856 4SP/4SH SAE 100 R1/R2, PARKER – MARKWEL, EN 853 1 ST PIX, /ISN/2ST/2SN SUPERSEAL PIPE FITTINGS 14 HYD – AIR, PARKER, HYLOC – HYDROTECHNIC, STAUFF QUICK RELEASE COUPLINGS 15 AEROQUIP, PARKER, STAUFF, STERLING, HOLMBURY PRESSURE GAUGES 16 WIKA, PARKER – UCC MINIMESS HOSE & COUPLINGS 17 PARKER, STAUFF, HYDROTECHNIC ** CRITICAL MEANS THE ITEMS WHOSE FAILURE MAY CAUSE MORE THAN TWO HOURS PRODUCTION LOSS II PNEUMATIC EQUIPMENTS AND SPARES 1 AIR BOOSTER PUMPS/ INTENSIFIERS 2 a) CONTROL VALVES b) DIRECTIONAL CONTROL VALVES c) PRESSURE CONTROL VALVES d) FLOW CONTROL VALVES e) LOGIC CONTROL VALVES 3 MAXIMATOR, HASKEL PARKER, ROSS, NUCON, SPIRAX, MARTONAIR, SCHRADER BELLOW, CROUZET TELEMECANIQUE, FESTO AIRMATIC, PARKER, VEIJAN HYDRAIR, SCHREDER BELLOWS, NUCON, a) AIR PREPARATION UNITS b) FILTERS c) REGULATORS d) LUBRICATORS e) COMBINATION UNITS Appendix-6 List of approved vendors. Page 3 of 32 4 5 f) DIFFUSERS g) SILENCERS h) MUFFLERS i) BREATHERS AIR DRIERS PIPES & FITINGS VARIOUS TYPES OF PIPE FITTINGS, PVC, PU AND NYLONE TUBINGS FESTO, HYDROLINE EMSKAKY MECMAN, LEGRIS, PARKER TOOLS & TACKLES 1 2 3 4 5 6 7 8 9 10 11 12 13 HACKSAW BLADE FILES SLEDGE HAMMER BALL PIN HAMMER ALLEN KEYS PILER REAMER SCREW DRIVER ADJUSTABLE SPANNERS D.E. SPANNER S.E. SPANNER RING SPANNER BOX SPANNER SET 14 THREADING TAPS 15 16 17 18 PIPE WRENCHES PNEUMATIC CHISELS DRILL CHUCK END MILL CUTTER 19 DRILLS 20 SLOT DRILLS 21 22 23 24 25 26 DRILL SLEEVES VERNIER CALIPER MEASURING STEEL TAPE BENCH VICE PUNCHES STEEL SCALE STAINLESS STEEL BAND SAW BLADE (FOR METAL) BAND SAW BLADE (FOR WOOD) CARBIDE TIPS 27 28 29 30 PHILLIP HEAD SCREW DRIVER PLIERS FOR CIRCLIPS (INTERNAL & EXTERNAL) MIRANDA, BIPICO, L & T JK, HINDUSTAN KUMAR, TAPARIA, EVEREST, TATA, AGRICO KUMAR, TAPARIA, EVEREST, TATA, AGRICO UNBRAKO, JHALANI, EVEREST, TVS, GKW TAPARIA , JHALANI, EVEREST ZENITH- ITM, ADDISON, JESON, SRP TAPARIA, JHALANI, EVEREST, MEKASTER TAPARIA, JHALANI, EVEREST, MEKASTER TAPARIA, JHALANI, EVEREST, MEKASTER TAPARIA, JHALANI, EVEREST, MEKASTER TAPARIA, JHALANI, EVEREST, MEKASTER JHALANI, EVEREST, MEKASTER, SNAP-ON, POWER MASTER, TRISTER ADDISON, ITI, JESON, SRP, TOTEM, JK, MIRANDA JHALANI, TAPARIA, EVEREST, MEKASTER APT, TAPARIA, CP, BOYD SMITH JUG, PITTIE ADDISON, ITI, JESON, SRP, TOTEM, ITM (ZENITH) ADDISON, JESON, ITI, SRP, JK FILES & TOOLS ADDISON, JESON, ITI, SRP, JK FILES & TOOLS, ITM (ZENITH) PITTIE, BHARAT, JK, TRUMAX MITUTOYO, FORBES FREEMAN, TRUFLEX APEX, CITCO BRADMA, R & R KRISTEEL SHINWA MIRANDA, BIPICO ESI, ANIL SANDVIK, ZENITH, KENNANETAL, SICO, RAPICUT CERATIZIT TAPARIA TAPARIA, SAM-FRANCE, SNAP-ON Appendix-6 List of approved vendors. Page 4 of 32 PORTABLE MAINTENANCE TOOLS A. ELECTRICAL EQUPTS. 1 2 3 4 5 6 ST. GRINDERS ANGLE GRINDERS DRILLING M/C BENCH GRINDERS 6” SANDERS/ POLISHERS SANDER M/S RALLIWOLF M/S BOSCH POWER TOOLS M/S KULKARNI POWER TOOLS M/S BLACK & DECKER B. LIFTING / PULLING EQUIPMENTS 1 PULLING & LIFTING M/C TIRFOR, MAXPULL, INDEF 2 3 HAND OPERATED CHAIN PULLEY BLOCK HAND OPERATED GEAR TRAVELING TROLLIES HYD. JACKS a) REMOTE CONTROLLED TYPE (OPERATING PRESSURE + 700 BAR) b) ELECT. HYD. POWER PACK (OPERATING PRESSURE + 700 BAR) INDEF INDEF HYD. BEARING PULLERS SUPER UNIQUE, OMAR STAR, POWER RAM 4 5 OEW, ORIONE, ENERPACK OEW, ORIONE, ENERPACK C. PNEUMATIC TOOLS 1 2 3 4 5 6 CHIPPING HAMMER ST. GRINDER ANGLE GRINDERS DRILLING M/C DIE GRINDERS IMPACT WRENCHES CPT PNE – TECH D. MISC. TOOLS 1 ISMAL MAKE 2 DIE LESS HYD. CRIMPING TOOLS (6- 500 SQ.MM. SIZE) RING SPANNERS OF ASSORTED SIZES 3 SOCKET SPANNERS TAPARIA, MEKASTER TAPARIA, JHALANI, EVEREST, MEKASTER III. EARTHMOVING EQUIPMENT & VEHICLES S.No. Equipment/ Vehicle Preferred makes 1. 2. KOMATSU BEML 3. 4. DOZERS (ENGINE HP UP TO 100) DOZERS (ENGINE HP MORE THAN 100 up to 450) DUMPERS (35 TON REAR DUMP) DUMPERS (50 T REAR DUMP) BEML HM, BEML Appendix-6 List of approved vendors. Page 5 of 32 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. HYDRAULIC EXCAVATORS (UP TO 1.5 CuM BUCKET CAP). EXCAVATORS (MORE THAN 1.5 CUM UP TO 3.50 CUM) EXCAVATORS (MORE THAN 3.50 CUM UP TO 5.50 CUM) EXCAVAOPRS WITH ROCK BREAKER (UP TO 1.0 CU M BUCKET CAPACITY) WHEELED LOADERS (UP TO 1.0 CU M BUCKET CAPACITY) WHEELED LOADERS (MORE THAN 1.0 CU UP TO 2.0 CU M) WHEELED LOADERS (MORE THAN 2.0 CU M UP TO 3.0 CU M) WHEELED DOZER (ENGINE HP UP TO 160) MOTOR GRADER (ENGINE HP UP TO 250) FRICTION CRAWLER CRANE (18 T – 20 T) TRACK TYPE LOADER (UP TO 2.0 CU M BUCKET SIZE) PICK AND CARRY CRANE (UP TO 8 T) HYDRAULIC ROUGH TERRAIN CRANE (UP TO 20 T) HYDRAULIC ROUGH TERRAIN CRANE (40 T – 45 T) TRACTOR (ENGINE HP UP TO 70) VIP CARS (ENGINE HP UP TO 100) JEEPS (ENGINE HP UP TO 100) PICKUP VAN (ENGINE HP UP TO 100) TRUCKS (ENGINE HP UP TO 140) TIPPERS (ENGINE HP UP TO 140) AMBULANCE (ENGINE HP UP TO 100) LIME TANKERS (ENGINE HP UP TO 170, 12 T CAPACITY TANKER) WATER TENDERS (ENGINE HP UP TO 170) FOAM TENDERS (ENGINE HP UP TO 170) EME TENDERS (ENGINE HP UP TO 170) DCP TENDERS (ENGINE HP UP TO 170) COMB. TENDERS (ENGINE HP UP TO 170) GARBAGE TRUCKS (ENGINE HP UP TO 140) WATER TANKERS (ENGINE HP UP TO 140) BEML L & T, TITAGARH WAGON BEML TATA HITACHI ESCORTS, JCB BEML, HM BEML BEML BEML TELCON CATERPILLER ESCORTS VOLTAS OMEGA, ESCORTS VOLTAS OMEGA HMT HINDUSTAN MOTORS MAHINDRA & MAHINDRA TATA TATA, ASHOK LEYLAND TATA, ASHOK LEYLAND TATA TATA TATA, ASHOK LEYLAND TATA, ASHOK LEYLAND TATA, ASHOK LEYLAND TATA, ASHOK LEYLAND TATA, ASHOK LEYLAND TATA, ASHOK LEYLAND TATA, ASHOK LEYLAND IV. INDIGENOUS EOT CRANE 1 2 3 HOT METAL HANDLING FOUR GIRDER CRANE, LADLE HANDLING CRANE - 2 GIRDER & 4 GIRDER, MILL DUTY CRANES, MAGNET CRANES, TONGS CRANES & GRAB MAGNET CRANES SERVICE CRANES USED IN VARIOUS SHOPS - CLASS-2, 3 DUTY CAPACITY UP TO 300 T SERVICE CRANES UP TO 200T CAPACITY M/S HEC M/S JESSOP M/S MUKAND M/S HEC M/S JESSOP M/S MUKAND, MUMBAI M/S HEC M/S JESSOP M/S MUKAND, MUMBAI M/S WMI Appendix-6 List of approved vendors. Page 6 of 32 4 SERVICE CRANES UP TO 50 T CAPACITY M/S ANUPAM M/S UNIQUE INDUSTIRES M/S FAFE CO M/S HEC M/S JESSOP M/S MUKAND, MUMBAI M/S WMI M/S ANUPAM M/S UNIQUE INDUSTIRES M/S FAFE CO SHAKTI INDUSTIRES V. AIR CONDITIONING AND VENTILATION EQUIPMENT 1 ROOM AIR CONDITIONERS - CAP 1.5 TR AS PER IS 2 SPLIT AIR CONDITIONERS INCLUDING CASSETTE TYPE, WALL MOUNTED FLOOR MOUNTED AND CEILING MOUNTED - CAP. 1.5 TR & 2 TR DUCTABLE AND TOWER TYPE AIR CONDITIONERS - CAP. 5.5 TR 3 4 PACKAGE AIR CONDITIONERS (WATER COOLED) 5- TR, 7.5 TR, 10 TR & 15 TR 5 PACKAGE AIR CONDITIONERS (AIR COOLED) – CAP - 5 TR & 7.5 TR 6 PACKAGE (CAP - AS PER REQUIREMENT) AIR CONDITIONERS FOR HIGH AMBIENT TEMPERATURE (ABOVE 55 DEG C) FRO APPLICATIONS LIKE CRANES, MOBILE EQUIPMENT ETC. CENTRAL AIR CONDITIONERS (CAP. 30 TR AND ABOVE) VAPOUR COMPRESSION TYPE WITH WATER COOLED CONDENSERS ONLY WITH OPEN TYPE RECPROCATING COMPRESSORS AIR HANDLING UNITS FOR CHILLED WATER COOLING SYSTEMS (CAP - AS PER REQUIREMENT) AIR WASHER UNITS AND PLENUM VENTILATION SYSTEMS (CAP. MINIMUM 10,000 CUM/HR AND IN MULTIPLES OF 10,000 CUM/HR AND UP TO 1,20,000 CUM/HR FOR NORMAL CASES) 7 8 9 VOLTAS, LG VIDEOCON, BLUESTAR, ELECTROLUX SIEL AIR CON (NOT RECOMMENDED FOR CONTINUOUS OPERATION) VOLTAS, BLUE STAR, LG, DAIKIN, VIDEOCON VOLTAS BLUE STAR, LG, CARRIER, DAIKIN VOLTAS, MESINA, BLUE STAR, FRICK, FEDDERS LLOYD, BATLIBOI VOLTAS, MESINA, BLUE STAR, FRICK, FEDDERS LLOYD, BATLIBOI LINTERN, WEISSHAR, FRIGORTEC, SULTZER, PHILIP DOYAL VOLTAS, BATLIBOI BLUE STAR, FRICK C. DOCTOR, FRICK, VOLTAS, BLUE STAR, MESINA SAKET, S.K. SYSTEMS, MESINA, VOLTAS, AIR TECHNIKO, F.HARLEY - FOR SYSTEMS OF CAPACITY UP TO 80,000 CUM/ HR AND Appendix-6 List of approved vendors. Page 7 of 32 ACCO, C.DOCTOR, VOLTAS, ABB FOR SYSTEMS OF CAPACITY UP TO 1,20,000 CUM/ HR 10 11 WATER COOLERS OF STORAGE TYPE (CAP - 80/ 40 LITERS) REFRIGERATORS (CAP. 165 LT TO 265 LT) 12 SEALED ROTARY/ RECIPROCATING/ SCROLL COMPRESSORS FOR ROOM AIR CONDITIONERS AND SPLIT TYPE AIR CONDITIONERS (CAP. 1.5 TR & 2 TR) 13 SEALED ROTARY/RECIPROCATING /SCROLL COMPRESSORS FOR PACKAGE AIR CONDITIONERS - CAP. 7.5 TR SEMI SEALED COMPRESSORS FOR PACKAGE AIR CONDITIONERS UP TO 15 TR. OPEN TYPE COMPRESSORS FOR PACKAGE AND CENTRAL AIR CONDITIONERS. 14 15 (CAPACITY CAN BE REVIEWED FOR SPECIAL CASES) VOLTAS, USHA, SHRIRAM, BLUE STAR GODREJ, VIDEOCON, LG, KELVINATOR, WHIRLPOOL, SAMSUNG SHRIRAM TECUMESH, HITACHI, KIRLOSKAR COPLAND CARRIER, DAIKIN KIRLOSKAR COPLAND, INDFOSS/ DAFOSS, DAIKIN, CARRIER VOLTAS, BATLIBOI, KIRLOSKAR, PNEUMATIC FRICK, FREEZE KING, KIRLOSKAR, PNEUMATIC, BOCK, ACCEL, BLITZER, SULTZER, BATLIBOI (DAIKIN), VOLTAS VI CABLES Category of Cables Vendors HT XLPE Cables (IS 7098 P-II-1985) 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. LT XLPE Cables ( IS 7098 P-I,1985) Crystal Cables KEI Industries Fine cab Cable Cable Corporation of India NICCO Cables Poly Cab Cables R.P.G. Cables Uniflex Cables Universal Cables Krishna Elect. Industries Torrent Cables Shriram Cables Crystal Cables Gloster Cable Fine Cab Cable Gems Cab Ind. Delhi Krishna Elect.Industries Ravin Cables Ltd, Maharashtra. Mansfield Special Cable Pagoda Cables Teracom Appendix-6 List of approved vendors. Page 8 of 32 Rubber Cables (IS-9968 Pt-1) (EPR /CSP, VIR/TRS & SR cables) HRPVC Cables (IS 1554: Pt 1: 88 -license Endorsed for insulation of Type C & sheath ST2) (Power & Control Copper & Aluminium -Armored & Unarmored) PVC Control cables (IS 694) 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 1. 2. 3. 4. 5. 6. KEI Industries Poly Cab Uniflex RPG Cables NICCO Universal Cables Cable Corporation of India Havells India LTD. Insucon Cables CAPCAB Ind, N Delhi I M T CABLES Nangalwala Impex United Cables Bhagwati Cables Cable Corpo of India Govind Cables KEI Industries NICCO Cables Shyam Cables Sky Tone Elect. Uniflex Cables Universal Cables Servel cables K. N. G. PLASTIC Mansfield Cables R J Elect. BMI Cables TERACOM Pvt Ltd Ajanta Elect, Fine cab Cable Insucon Cables KEI Industries Shanti Cables Shyam Cables Servel Cables GEMS Cab Mans Field Cables Pagoda Cables Universal Cables Electrical Cable Indu. Special cable BMI Cables Brimson Cables RJ Indu. Diamond Power Grid India power cable Bhansali Cables Kalinga Cables & conduit Co. Asian cable Co, Raigarh Paragon cable India ltd Rishabh Industries Bhansali Gems Cab Industries, Delhi Servel Pvt. Ltd. Mansfield Special Cables Appendix-6 List of approved vendors. Page 9 of 32 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. Thermocouple, Compensating Cables, PTFE Cables Welding Cables IS 9857 (Aluminium & Copper) Data Communication, Instrumentation, Screened , Co-axial and special Cables Pagoda Ravin Cables Super Star Cable Brimson Cables Vijaya Cables Electrical Cable Ind. BMI Cables Pvt. Ltd. Teracom Cables Insucon Cables Guardin Cables & Conductors CAPCAB Ind, N Delhi Ajanta Elect, Asian cable Co, Raigarh Paragon cable India ltd Thermo Cable Industries, Hyd, Sri Siddhi Vinayak ind, Indore POLYFLEX cables Pvt Ltd, Delhi 1. Skytone Elect. 2. Toshniwal Cables 3. Servel cables 4. Paramount Cables 5. M.E.M. Industries, Kolkolta 6. Electrical Cable Indu. 7. Cap Cab Cables 8. R.J. Industries. Corporation. 9. Mansfield Cable Corporation. 10. TERA COM 11. Special cable 12. Pagoda Cables 13. Udey pyro cables 14. Brooks Cables 15. Cords Cables 16. Friends Cables 17. Makcon Industries, Raipur 1. IMT Cable Pvt. Ltd, New Delhi. 2. K.N.G. Plastic, 3. Nangalwala Impex 4. Poly cab wires Mumbai. 5. Uniflex Cables Ltd, 6. Skytone cables, Faridabad. 7. Universal cables Satna. 8. NICOO corpo. Kolkata. 9. Shyam Cable. 10. Teracom 11. Super Star Cable 12. Bhagwati Cables 13. Govind Cable Industries 1. Toshniwal Cables 2. Delton 3. Finolex Cables 4. LAPP. Cables 5. M.E.M. Industries 6. R.P.G. Cables 7. Uniflex Cables 8. Servel cable Appendix-6 List of approved vendors. Page 10 of 32 9. 10. 11. 12. 13. 14. 15. 16. Telephone Cables Optical Fibre Cable, UTP Cable, Data cables, Profibus cables HT Trailing Cables IS 9968-II (Reeling & Unreeling Duty) Arial Bunch Cables High temperature fire survival cables for special applications Mansfield Cable Co. TERA COM Special cable Pagoda Cables Universal Cables Brooks Cables Asian cables Bhansali Cables 1. Shri Ram cables, Delhi 2. Bhansali Cables & Conductors Pvt. Ltd, New Delhi. 3. Birla Ericsson Optical Ltd, Rewa. 4. Delton Cables Ltd, New Delhi. 5. Finolex Cables, Pune. 6. Paramount communications Ltd, New Delhi. 7. Elkay Telelinks Ltd., Faridabad. 8. Vindhya Telelinks, Rewa. 9. Usha Beltron Ltd ,Ranchi. 10. Uniflex Cables 1. Avaya 2. Lucent Technologies 3. Molex Ltd, Bangalore 4. Paramount 5. Tera Com 6. Finolex Cables 7. Uniflex Cables 8. Birla Ericsson Optical Ltd, Rewa. 9. Systimax, 10. Amp India Limited, Banglore 11. Bhansali Cables 12. Dax networks ltd, Chennai 1. Cable Corporation of India 2. NICCO Cables 3. Sky Tone Elect. 4. Uniflex Cables 5. Universal Cables 6. KEI Industries Limited 1. Hindustan Vidyut Products Ltd 2. Laxmi Power Cables, Mumbai 3. Shri Ram cables 4. R.J. Industries. Corporation. 5. CAPCAB Ind, N Delhi 6. Paramount Cables 7. Ravin Cable 8. Chandresh Cables Ltd., Ahemdabad 1. Tyco thermal controls India Pvt Ltd. 2. HELUKABEL 3. LAPP. Cables VII. LAMPS & FIXTURES 1 LAMPS (GLS) PHILIPS, BAJAJ, OSRAM, MYSORE LAMPS, SURYA ROSHNI, CROMPTON GREAVES, G.E. LIGHTING, WIPRO Appendix-6 List of approved vendors. Page 11 of 32 2 LIGHTING FICTURES 3 FLAME PROOF FITTINGS 4 AVIATION LIGHTS 5 EXPLOSION PROOF LIGHTING FITTINGS PHILIPS, BAJAJ, MYSORE LAMPS, CROMPTON GREAVES, G.E. LIGHTING, WIPRO, DEEPSON BALIGA, BANGALORE; BAJAJ, FLEX PRO., KOLKATA, HANSU – CONTROL, MUMBAI BINOY, PHILIPS, G.E. LIGHTING, ALTOS, PUNE GOVAN INDUSTRIES, MUMBAI (*) M/s Mysore Lamps & M/s Surya Roshni should give ‘Quality Assurance’. VIII. HV EQUIPMENTS 1 2 220 KV & 132 KV POWER TRANSFORMERS UP TO 160 MVA 33 KV, 11 KV, 6.6 KV OIL FILLED/ DRY TYPE DISTRIBUTION/ RECTIFIER TRANSFORMERS 1000 KVA AND ABOVE 2A 33 KV, 11 KV, 6.6 KV OIL FILLED/ DRY TYPE DISTRIBUTION/ RECTIFIER TRANSFORMERS BELOW 1000 KVA 3 33 KV, 11KV, 6.6 KV OIL FILLED FURNACE TRANSFORMERS 220 KV AND 132 KV SF 6 CIRCUIT BREAKERS 33 KV, 22 KV, 11 KV, 6.6KV VACUUM CIRCUIT BREAKERS 4 5 6 7 8 9 10 11 12 6.6 KV, 11 KV VACUUM CONTRACTORS 220 KV AND 132 KV CURRENT TRANSFORMERS (CT) 33 KV, 22 KV, 11 KV, 6.6 KV CURRENT TRANSFORMERS (CT) 220 KV AND 132 KV VOLTAGE TRANSFORMER (PT) 33KV, 22KV, 11KV, 6.6KV VOLTAGE TRANSFORMER (PT) 220 KV AND 132 KV CAPACITANCE VOLTAGE TRANSFORMER (CVT) 220 KV AND 132 KV LIGHTINING ARRESTOR (LA) BHEL, TELK, CGL, EMCO, AREVA, ABB, SIEMENS CGL, AREVA, TRANSFORMERS & RECTIFIERS LTD, KEC, INTRA VIDYUT, KANOHAR, VOLT AMP, BHARAT BIJLEE, ANDREW YULE, BHEL, EMCO, ABB, SIEMENS CGL, AREVA, TRANSFORMERS & RECTIFIERS LTD, KEC, INTRA VIDYUT, KANOHAR, VOLT AMP, BHARAT BIJLEE, ANDREW YULE, BHEL, EMCO, ABB, SIEMENS, STAR DELTA TRANSFORMERS LTD, SOMANI ELECTRICAL PVT LTD, VISHAL TRANSFORMERS, SHILCHAR ELECTRONICS LTD, ATLANTA ELECTRICAL PVT LTD, EMCO LTD, JALGAON. CGL, EMCO, AREVA, BHEL, ABB ABB , CGL, SIEMENS AREVA SIEMENS, BHEL, CGL, SCHNEIDER, AREVA, ABB, JYOTI (JYOTI – UP TO 11 KV ONLY) BHEL, AREVA, SIEMENS, ANDREW YULE, JYOTI, CGL ABB, TELK, BHEL, CGL, AREVA PRAGATI,INSTRANS, PRAYOG, INTRAVIDYUT, INSUTECH INDUSTRIES, ABB ABB, TELK, BHEL, CGL, AREVA ABB, PRAGATI, PRAYOG, INTRAVIDYUT, JYOTI AREVA, ABB, CGL, BHEL, OBLUM, ELPRO, AREVA, CGL, Appendix-6 List of approved vendors. Page 12 of 32 13 220 KV AND 132 KV ISOLATORS 14 33KV, 11KV, 6.6KV ISOLATORS LOAD BREAK SWITCH 11 KV AIR – BREAK SWITCH 15 16 220 KV AND 132 KV CONDENSER BUSHINGS 17 20 33KV, 11 KV, AND 6.6 KV CAPACITORS 33KV, 11KV, AND 6.6KV SURGE SUPPRESSORS 33KV, 22KV, 11KV, 6.6KV CABLE JOINTING KITS (HEAT SHRINKABLR TYPE) BATTERY CHARGERS 21 21 A LEAD ACID STATION BATTERY BATTERIES FOR OTHER APPLICATION 21B 22 NICKEL – CADMIUM BATTERIES ELECTRONIC ENERGY METERS (TRIVECTOR / KWH) 23 24 PROTECTION & AUXILIARY RELAYS RECORDERS (CHARTLESS TYPE) 25 ANNUNCIATORS 26 PANEL/ INDICATING METERS 27 LT AIR CIRCUIT BREAKERS 28 EHT/HT INSULATORS 1. PORCCLAIN INSULATOR 18 19 2. EPOXY INSULATOR 29 HT HRC FUSES S&S, PONDICHERRY, ELPRO, WSINSULATORS, ABB, AREVA, CGL A- BOND STRANDS, DRESCHER & PANICKER, ABB, SIEMENS, CGL PACTIL, PANCHKARI & KAYAL & CO., A-BOND STRAND, PANIKER BHEL, CGL, AREVA, TELK (THE TRANSFORMER MANUFACTURERS MAY GIVEN THEIR OWN/ ANY OTHER MAKE WITH QAP) ABB, UNISTAR (UNIVERSAL CABLE), BHEL, MEHER, BANGALORE. OBLUM, ELPRO, WSISOLATORS,TOSHIBA, SIEMENS RAYCHEM, M/S HEAT SHRINK TECHNOLOGY, 3M (FOR 11 KV AND 6.6 KV) CHHABI ELECTRICALS, STANDARD, HI-RECT., SHERENE ELECTRO CONTROL, AMARA RAJA EXIDE, AMCO, AMARA RAJA EXIDE, KIRLOSKAR BATTERIES, CELTEK, HBL – NIFE, MYSORE THERMO ELECTRIC, BUI AMCO, SAB-NIFE SEMS, L&T, SATEC, CONZERVE, DUKATI, ABB, SIEMENS, AREVA, SCHNEIDER ABB, SIEMENS, L&T, AREVA, SCHNEIDER CHINO, YOKOGAWA INDIA LTD, OKHURA, FUJI, EUROTHERM (CHESSEL), TATA HONEYWELL, HIOKI, FLUKE, ABB, PYROTECH, UDAIPUR. MINILEC, SPA, PROCON, UASHMUN, PYROTECH (UDAIPUR) IMP, AE, MECO, L&T, MOTWANI, CONZERVE L&T, SIEMENS, SCHNEIDER, ABB, GE POWER CONTROL, CONTROL & SWITCHGEAR (TRIAL PARTY). WS- INSULATORS, JAYASHREE, BHEL, A-BOND STRAND, S&S, AREVA, OBLUM A-BOND STRAND, POWER CAM ELECTRICAL PVT LTD, BARODA; BUSHINGS, S & C ELECTRIC CO. (AMERICA), RISHO KOGYO CO. LTD (JAPAN) S&S, GE POWER CONTROL, BUSMAN, SIEMENS, ABB, Appendix-6 List of approved vendors. Page 13 of 32 30 DRESCHER PANIKER BEST & CROMPTON, ECC (KOLKATA), STAR DRIVE (CHENNAI), ENPRO (CHENNAI), ADVANCE POWER CONTROL (ADVANCE POWER CONTROL ONLY FOR LV BUS DUCT) HV/ LV BUS DUCT IX. L V EQUIPMENTS 31 MOULDED CASE CIRCUIT BREAKER (MCCB) 32 MOTOR PROTECTION CIRCUIT BREAKERS (MPCB) 33 MANIATURE CIRCUIT BREAKER (MCB) 34 EARTH LEAKAGE CIRCUIT BREAKER 35 SWITCH FUSE UNIT / FUSE DISCONNECTOR (FUSE SWITCH UNIT), AIR BREAK SWITCH 36 HRC FUSE FOR LT APPLICATION 37 POWER CONTACTOR FOR CRANE/ MILL DUTY OPERATION 1. BOX TYPE (AC/DC) 38 SCHNEIDER (CG & MG), L&T ANDREW YULE, ABB, SIEMENS, BCH (BIL), GE POWER CONTROL, MOELLER, CONTROL & SWITCHGEAR. SCHNEIDER (TELEMECANIQUE), L&T, ABB, GE POWER CONTROL, MOELLER, ROCKWELL AUTOMATION, CONTROL & SWITCHGEAR. SIEMENS, L&T, GE POWER CONTROL, SCHNEIDER (PROTEC/MG), STANDARD, INDOASIAN, HAVELLS, MDS (LEGRAND), ABB, CONTROL & SWITCHGEAR. GE POWER CONTROL, STANDARD, HAVELLS, ABB, SIEMENS, SCHNEIDER GE POWER CONTROL, L&T, SIEMENS, BASANT PRAN & CO, HAVELLS, STANDARD, INDO-ASIAN, CONTROL & SWITCH GEAR, ANCHORE GE POWER CONTROL, L&T, SIEMENS, BHARAT LINDER, INDO ASIAN, HAVELLS, STANDARD, BUSSMAN, CONTROL & SWITCH GEAR, ABB ABB, SIEMENS, SCHNEIDER, (TELEMECANIQUE), L&T, MOELLER, GE POWER CONTROL, ROCKWELL, AUTOMATION, CONTROL & SWITCHGEAR (TRIAL PARTY). 2. VACUUM CONTACTOR SIEMENS, L&T, MOELLER, ABB, SCHNEIDER (TELEMECANIQUE), 3. AC/DC POWER CONTACTOR – BCH (BIL), BHEL, L&T, SCHNEIDER CLAPPER TYPE/ BAR MOUNTED – (TELOMECANIQUE), GE (USA), ABB, MILL DUTY/ CRANE DUTY LENIOR ELEC (FRANCE), MICROELECTRICA SCIENTIFIC (ITALY) POWER CONTACTOR FOR ABB, SIEMENS, SCHNEIDER, L&T, GENERAL PURPOSE & ROCKWELL AUTOMATION, CONTINOUS DUTY OPERATION ANDREW YULE, SCHNEIDER (CG) BCH (BIL), MOELLER, CONTROL & Appendix-6 List of approved vendors. Page 14 of 32 SWITCH GEAR 39 OVER LOAD RELAY 1. THERMAL (BIMETALLIC) 2. ELECTRONIC OVER LOAD RELAYS 40 41 3. ELECTRO MAGNETIC OVER LOAD RELAY AUX. CONTRACTORS/ CONTROL REALYS TIME DELAY RELAY 1. ELECTRO PNEUMATIC BCH (BIL), SCHNEIDER (TELOMECANIQUE), BHEL, ESAUN REFOLLE SELECTRON, SIEMENS, BCH (BIL), ALSTOM, L&T, ROCKWELL AUTOMATION IFM, SCHNEIDER (TELOMECANIQUE) L&T, GE POWER CONTROL, EAPL, INDO ASIAN, SCHNEIDER (MG) EPCC, INDUSTRIAL SYNDICATE, STROM KRAFT, SCHNEIDER (SQUARE D), SCHNEIDER (TELEMECANIQUE) 2. ELECTRONIC TMER 3. TIME SWITCHES 42 MASTER CONTROLLER 43 LIMIT SWITCHES 1. CRANE & HEAVY DUTY APPLICATION 2. MICRO & OTHER ACTUATING TYPE 44 45 BCH (BIL), L&T, SIEMENS, SCHNEIDER (TELOMECANIQUE), ANDREW YULE, SCHNEIDER (C.G.), ROCKWELL AUTOMATION, CONTROL & SWITCHGEAR. SIEMENS, L&T, ROCKWELL AUTOMATION, MOELLER, BCH, SCHNEIDER – SAMWHA BCH, KILBURN, BHEL, SCNEIDER (TELEMECANIQUE) OEN, L&T,SCHNEIDER, ANDREW YULE, GE POWER CONTROL, BCH (BIL), EASUN REROLLE, JYOTI, ROCKWELL AUTOMATION, CONTROL & SWITCHGEAR. RESISTANCE BOXES (FECHRAL EDGE WOUND) ELECTROMAGNETIC DC BRAKE ASSEMBLY EPCC, SCHNEIDER, INDUSTRIAL SYNDICATE, STROM KRAFT, JAI BALAJI ESSEN DEINKI, L&T, BCH (BIL), SIEMENS, SCHNEIDER (TELEMECANIQUE), JAI BALAJI EPCC, RSI, KINGS, TALSON EPCC, BCH (BIL), INDUSTIRAL SYNDICATE X. POWER CONTROL AND ELECTRONICS ITEMS 46 47 THYRISTOR CONVERTERS 1. GENERAL PURPOSE UP TO 1 KA 2. CRITICAL APPLICATION UP TO 5 KA 3. CRITICAL APPLICATION MORE THAN 5 KA PLC BHEL, SIEMENS, SSD DRIVES, ABB, NELCO, ABIL, CONVERTEAM BHEL, SIEMENS, ABB, SSD, CONVERTEAM, ROCKWELL AUTOMATION BHEL, SIEMENS, ABB, CONVERTEAM ROCKWELL AUTOMATION, L&T (QUANTAM), SIEMENS, ABB, GE Appendix-6 List of approved vendors. Page 15 of 32 FANUE, BCH, SCHNEIDER ABB, ROCKWELL AUTOMATION, BHEL, SCHNEIDER, N.N. PLANNER, SIEMENS, INNOVATIVE TECHNOMICS, KIMO ELECTRONICS, TOSHIBA 48 SOFT STARTERS (LT MOTOR) 49 SOFT STARTERS (FOR HT MOTORS) 1.WITH ENERGY SAVING MODE 50 2. WITHOUT ENERGY SAVING MODE VVVF DRIVES 1. GENERAL PURPOSE LT MOTORS 2. CRITICAL APPLICATION FOR LT MOTORS 3. FOR HT MOTORS MV DRIVE/ HI-LO-HI DRIVE 51 THYRISTOR DEVICES 52 POWER DIODES 53 54 CONTROL DIODES SEMICONDUCTOR FUSES 55 UPS FOR GENERAL DUTY 55A UPS FOR INDUSTRIAL DUTY 56 IGBT ABB, ROCKWELL AUTOMATION, BHEL, SIEMENS INNOVATIVE TECHNOMICS ABB, ROCKWELL AUTOMATION, BHEL, SIEMENS, NELCO (HITACHI), T.B. WOOD, VACON, SCHNEIDER, SSD DRIVES, JELTRON (TOSHIBA), L&T (YASKAWA) ABB, BHEL, SIEMENS, L&T, (YASKAWA), SCHNEIDER, VACON, ROCKWELL AUTOMATION, SSD, JELTRON (TOSHIBA) ABB, ROCKWELL AUTOMATION, BHEL, SIEMENS, CONVERTEAM (UK), TMEIC WEST CODE, ABB, BHEL, EUPEC, HIND RECFIFIER, RUTTON SHAW, SEMIKRON RECTIFIER RUTTON-SHAW , USHA RECTIFIER, HIND RECTIFIER, INSEL, SEMIKRON RECTIFIER, WEST CODE, EUPEC ECIL, BEL, HIND RECTIFIER, INSEL GE POWER CONTROL, SIEMENS, LA-FERRAZ, BUSSMAN HI-REL, ILK (FUJI), TATA LIBERT (EMERSON), SIEMENS, APC-MG TVSE, DB POWER ELECTRONIC (P) LTD, APLAB HI-REL, ILK (FUJI), TATA LIBERT (EMERSON), SIEMENS, DB POWER ELECTRONIC (P) LTD, APLAB WEST CODE, FUJI, EUPEC XI. MOTORS 57 LT SQUIRREL CAGE MOTORS 58 LT SLIPRING MOTORS (CRANE/ MILL DUTY) LT AC ROLL TABLE MOTORS 59 ABB, BHARAT BIJLEE, CGL, KEC, LAXMI HYDRAULIC PVT LTD, (SOLAPUR), MARATHON, SIEMENS, ELGI, JYOTI, NGEF, SEW, NORD, HINDUSTAN MOTORS, LENZE, EMIC, SIMO, MBH. CGL, MARATHON, KEC, BHARAT, BIJLEE, EMIC KEC, CGL, MARATHON, ABB, SEW, MARK ELECTRIC, BAUER, LHP, EMIC, DARSHANA MOTORS & Appendix-6 List of approved vendors. Page 16 of 32 60 LT AC GEARED MOTORS 60A GEARED MOTORS FOR CRANE AND ROLL TABLE APPLICATION 61 HT AC MOTORS (SQUIRREL CAGE SLIPRING & SYNCHORONOUS MOTORS) LT FLAME PROOF SQUIRREL CAGE MOTOR 62 63 STALL TORQUE VIRBATOR MOTOR 64 65 ACTUATOR MOTORS DC MOTORS ENGINEERING PVT. LTD. LAXMI HYDRAULICS PVT LTD. (SOLAPUR), INTERNATIONAL COMBUSTION, RAJENDRA ELECTRICAL INDUSTRIAL LTD, MUMBAI (REMI), BONFIGLIOLICOIMBATORE, POWER BUILD, SEW, NORD, LENZE. INTERNATIONAL COMBUSTION, SEW, NORD, BAUER, DEMAG, LENZE MARATHON, CGL, KEC, ABB, BHEL, JYOTI, SIEMENS, WEG, TMEIC MARATHON, BHARAT BIJLEE, CGL, KEC, LAXMI HYDRAULICS PVT LTD, (SOLAPUR) DEMAG, ELECTROMAG, INTERNATIONAL COMBUSTION, NORD, ELECTRO MAGNETICS, BOSECO, DARSHANA MOTORS & ENGINEERING PVT. LTD. AUMA, ROTORK, LIMITORQUE KEC, BHEL, CGL, IEC, BANGALORE; EMIC XII. ELECTRONIC COMPONENTS/ SENSORS 66 67 PROXIMITY SWITCHES (INDUCTIVE, CAPACITIVE AND MAGNETO) ENCODER 68 ZERO SPEED SWITCH 69 SENSORS/ SWITCHES *LIGHT BARRIERS *DISTANCE *LEVEL SWITCH MODE POWER SUPPLY 70 71 ELECTRONIC FLOW SWITCHES FOR OIL/ AIR/ WATER IFM, SIEMENS, SICK, ROCKWELL AUTOMATION, PEPPERL FUCHS, SCHNEIDER IFM, HUBNERM, HEIDENDINE, LEONARD, DIPL, ENG.H. WENGORZ, GmbH, SICK SCHNEIDER – SAMWHA, IFM, ROCKWELL AUTOMATION, SIEMENS, PEPPERL + FUCHS, PYROTECH IFM, SICK, ROCKWELL AUTOMATION, PEPPERL + FUCHS, SIEMENS, SCHNIEDER, DIMETIX AG SIEMENS, IFM, ROCKWELL AUTOMATION, BHEL, SCHNIEDER, HONEYWELL EVERLY, NELCO, IFM, SCHNIEDER, SIEMENS, KRONE, ENDRESS & HAUSSER (E&H) XIII. PANELS & PANEL COMPONENTS (LOW VOLTAGE) 72 73 PANEL BOARD (FIRE RETARDENT BOARD) PANEL ENCLOSURES LAMTUF PLASTIC, HYDERABAD EPCC, BCH, RITTAL, TRANSRECT, ADVANCE POWER CONTROL, CONTROL & SWITCHGEAR. Appendix-6 List of approved vendors. Page 17 of 32 74 TERMINAL BLOCKS 75 SELECTOR SWITCHES & CONTROL SWITCHES 76 CONTROL TRANSFORMERS 77 MIMIC PANELS & ANNUCIATION PANELS 78 M.C.C. (DRAW OUT TYPE) 79 M.C.C. (NON DRAW OUT TYPE) 80 POWER DISTRIBUTION BOARDS (PDB) / ROLL TABLE DISTRIBUTION BOARDS 81 POWER CONTROL CENTRE (PCC) 82 LOCAL CONTROL STATION (LCS) & CONTROL DESK STATION EPCC, ELMEX, PHONIX CONTACT, CONNECT WELL, ESSEN DEINKI, WAGO ABB, GE POWER CONTROL, BCH, EPCC, KAYCEE, SIEMENS, TEKNIK, L&T, RECOM AEI, UNITECH, EPI, POWER & COMMUNICATIONS, TRANSRECT, ADVANCE POWER CONTROL, EEW, CONTROL & SWITCHGEAR. L&T, ADVANI OERLIKON, GE POWER CONTROL, BHEL, BCH, TRANSRECT, MINLEC, TIRUPATI ELECTRONICS, ADVANCE POWER CONTROL, CONTROL & SWITCHGEAR. SIEMENS, BCH, L&T, ANDREW YULE, SCHNEIDER ELECTRIC/ CGL, CONTROL & SWITCH GEAR, ABB, ADVANCE POWER CONTROL SIEMENS, BCH, MAHESWARI ELECT., L&T / ECC, ANDREW YULE, SCHNEIDER ELECTRIC/ CGL, CONTROL & SWITCH GEAR, ABB, GE POWER CONTROL, TRANSRECT, ADVANCE POWER CONTROL. TRIAL PARTIES – MEDITRON, SWITCHING CKT ABB, GE POWER CONTROL, ANDREW YULE, BCH, SCHNEIDER ELECTRIC, MAHESWARI ELECT, SIEMENS, L&T, TRANSRECT, HAVELLS, STANDARD, TRICOLITE, ADVANCE POWER CONTROL, CONTROL & SWITCHGEAR. EPCC, BCH, TRANSRECT INDUSTIRES, ANDREW YULE, SCHNEIDER ELECT., CONTROL & SWITCH GEAR, L&T, SIEMENS, MAHESHWARI ELECT, GE POWER CONTROL, ABB, NGEF, ADVANCE POWER CONTROL. TRIAL PARTIES – MEDITRON, PECON, SWITCHING CKT, HANSU CONTROL, MANJUSHREE EPCC, BCH, TRANSRECT INDUSTIRES, ANDREW YULE, SCHNEIDER ELECT., CONTROL & SWITCH GEAR, L&T, SIEMENS, MAHESHWARI ELECT, GE POWER CONTROL, ABB, NGEF, ADVANCE POWER CONTROL, EEW (EEW FOR INDOOR APPLICATION ONLY). TRIAL PARTIES - MEDITRON, Appendix-6 List of approved vendors. Page 18 of 32 83 MAIN LIGHTING DISTRIBUTION BOARD (MLDB) 84 PUSH BUTTONS 85 INDICATING LED LAMP ASSEMBLY 86 OPEN TYPE PANELS 87 CURRENT TRANSFORMER (LV) 88 CONTROL PANEL PECON, SWITCHING CKT, HANSU CONTROL, MANJUSHREE SIEMENS, L&T/ ECC, TRANSRECT, HAVELLS, STANDARD, SCHNEIDER ELECTRIC, MAHESWARI ELECT., GE POWER CONTROL, EEW (EEW FOR INDOOR APPLICATION AND UP TO 200 A ONLY), MDS, ADVANCE POWER CONTROL, TRIAL PARTIES – MEDITRON, SWITCHING Ckt.,S&S, CONTROL& SWITCHGEAR. GE POWER CONTOL, BCH, CONTROL & SWITCH GEAR, L&T, SIEMENS, TECHNIK, ESSEN, TELEMECHANIQUE. TRIAL PARTIES – VAISHNO, S&S BINOY, ESSEN DEINKI, SIEMENS, TECHNIK, BCH, L&T, ALTOS, CONTROL& SWITCHGEAR. EPCC, TRANSRECT, EEW , CONTROL& SWITCHGEAR. ABB, JAYSHREE, PRAGATI, KAPPA, INTRAVIDUT, CONTROL & SWITCHGEAR. SONITECH, EPCC, TIRUPATI ELECTRONICS, TRANSRECT, ADVANCE POWER CONTROL, EEW, CONTROL& SWITCHGEAR. XIV. TELECOM EQUIPMENTS 89 C.C.T.V. SYSTEM 1. CAMERA PELCO, SANYO, SHARP, SONY, SAMSUNG SHARP, HITACHI, PHILIPS, LG, SAMSUNG, SONY, SANYO 2. MONITOR 90 91 92 93 94 WALKIT – TALKIE SYSTEM 1. HAND HELD SETS 2. FIXED STATIONS DISTRIBUTED AMPLIFIER SYSTEM PROGRAMABLE LOUD SPEAKING INTER COM SYSTEM (PROPAM SYSTEM) CONFERENCING SYSTEM 1. AMPLIEFIERS 2. CHAIRMAN DELEGATE UNIT 3. SPEAKERS. NOTE : ALL UNIT SHOULD BE OF SAME MAKE (IN SET) DESPATCHER SYSTEM (EPABX)/ INTER COM/ HOT- LINES (ONLY EXCHANGE) MOTOROLA, YAESU, VERTEX STANDARD BOSCH, MEGA PHI-AUDIOCOM, BOSCH, MEGA BOSCH, AHUJA, MEGA, SHURE, STUDIO MASTER SIEMENS, ERICSSION, AVAYA, GLOBAL CONNECT, ALCATEL BUSINESS SYSTEM, NORTEL, Appendix-6 List of approved vendors. Page 19 of 32 95 96 97 98 99 100 BATTERIES (MORE THAN 400 AH) LEAD ACID BATTERIES / MAINTENANCE FREE BATTERIES TELEPHONE INSTRUMENT YARD COMMUNICATION SYSTEM SHOP ANNOUNCEMENT SYSTEM PUBLIC ADDRESS SYSTEM (PAS) CABLE JOINTING KITS OPTICAL FIBRE CABLE CORAL TELECOM EXIDE, AMARA RAJA, AMCO BEETEL, SIEMENS, PANASONIC PHI-AUDIO COM, AHUJA, MEGA, BOSCH AHUJA, PHILIPS, BOSCH, MEGA, STUDIO MASTER, SHURE RAYCHEM MOLEX, LUCENT, FINOLEX, ERICSON, STERLITE, HFCL, OPTEL XV. PAINTS - CATEGORY A – CRITICAL APPLICATION 1 2 3 4 5 6 7 8 ENAMEL PAINT AIR-CRAFT GREY COLOUR ENAMEL PAINT CANARY YELLOW COLOUR ENAMEL PAINT WHITE COLOUR (CRITICAL APPLICATION) ENAMEL PAINT SIGNAL RED COLOUR ENAMEL PAINT ALUMINIUM ORDINARY (CRITICAL APPLICATION) ENAMEL PAINT RED OXIDE (CRITICAL APPLICATION) ENAMEL PAINT ZINE CHROMATE HEAT RESISTANT ALUMINIUM PAINT M/S BOMBAY PAINTS & ALLIED PRODUCTS. M/S KANSAL NEROLAC PAINTS LTD M/S ASIAN PAINTS M/S JENSON & NICHOLSON M/S ICI PAINTS M/S ARCOY INDUSTRIES M/S BERGER PAINTS M/S SHALIMAR PAINTS CATEGORY B – (PROPRIETORY ITEMS) - CRITICAL APPLICATION 1 2 DUCO PAINT DULUX PAINT M/S ICI PAINTS CATEGORY – NON CRITICAL APPLICATION 1 ENAMEL PAINT BLACK COLOUR. 2. ENAMEL PAINT BLUE COLOUR. 3 4 ENAMEL PAINT GREEN COLOUR ENAMEL PAINT POST OFFICE RED COLOUR ENAMEL PAINT GREY COLOUR ENAMEL PAINT YELLOW COLOUR ENAMEL PAINT RED OXIDE NONCRITICAL APPLICATION) ENAMEL PAINT ALUMINIMUM ORDINARY (NON-CRITICAL APPLICATION) 5 6 7 8 M/S BOMBAY PAINTS & ALLIED PRODUCTS. M/S KANSAL NEROLAC PAINTS LTD M/S ASIAN PAINTS M/S JENSON & NICHOLSON M/S ICI PAINTS M/S BERGER PAINTS M/S SHALIMAR PAINTS M/S ARCOY INDUSTRIES M/S SYNORGANIC PAINTS PVT LTD, BHILAI. M/S SP INDUSTRIES, RAIPUR M/S KUKREJA INDUSTRIES, BHILAI. Appendix-6 List of approved vendors. Page 20 of 32 9 ENAMEL PAINT WHITE COLOUR (NON – CRITICAL APPLICATION) XVI. INSTRUMENTATION ITEMS A. FIELD INSTRUMENTS 1 1.1 PRESSURE INSTRUMENTS PRESSURE/DIFFERENTIAL PRESSURE GAUGE 1.2 A. PRESSURE/DIFFERENTIAL PRESSURE SWITCHES (MECH. TYPE) B. PRESSURE/ DIFFERENTIAL PRESSURE SWITCHES (ELECTRONIC TYPE) WIKA, ASHCROFT, BUDENBERG-UK, FORBES MARSHALL, WAAREE, STANDARD INSTRUMENT, H.GURU, A.N.INSTRUMENT, TIWAC (WALCHANDRA) SWITZER, SOLON, ASHCROFT, INDFOS IFM, WIKA, KOBOLD, HYDAC, WAAREE -WITH DIGITAL INDICATION 1.3 PRESSURE/ DIFFERENTIAL PRESSURE/ LEVEL/ FLOW TRANSMITTERS COMPACT TYPE PRESSURE TRANSMITTER TEMPERATURE INSTRUMENTS/ SENSORS EMERSON (ROSEMOUNT), HONEYWELL, YOKOGAWA, SIEMENS, E&H, ABB, FUJI (INDIA) IFM, E&H, KOBOLD, WIKA, ABB, FORBES MARSHALL, WAAREE 2.1 TEMPERATURE GAUGE 2.2 THERMOCOUPLE & RTD 2.3 THERMOWELL & THERMOCOUPLE ASSEMBLIES 2.4 TEMERATURE SWITCH 2.5 TEMPERATURE TRANSMITTER 2.6 INFRARED RADIATION PYROMETER (ON LINE/ PORTABLE) WIKA, ASHCROFT, BUDENBERG, WAAREE, STANDARD INSTRUMENT, H.GURU, MANOMETER INDIA, A.N.INSTRUMENT TEMPSENS, TEMPTECH, TOSHNIWAL INDUSTIRES, TEMCON, TECHNO INSTRUMENTS, OMEGA, WAAREE INSTRUMENTS TEMPSENS, KUMAR MANUFACTURING, TEMCON, TECHNO INSTRUMENTS, OMEGA, WAAREE INSTRUMENTS IFM, WIKA, KOBOLD, OMEGA, TRINITY TOUCH, E&H EMERSON (ROSEMOUNT), YOKOGAWA, HONEYWELL, MTL, PHOENIX, P&F, OSNA, RADIX, ABB, OMEGA, E&H LAND, RAYTEK, IRCON, KELLER HCW (CELLA TEMP-PS), MASIBUS (WILLAMSON GOLD), OMEGA 3 FLOW INSTRUMENTS/ SENSORS 3.1 ROTAMETERS 1.4 2 FORBES-MARSHALL, EUREKA INSTRUMENTS, CHEMTROLS, ROTA INSTRUMENTS, SMC, WAAREE Appendix-6 List of approved vendors. Page 21 of 32 3.2 ORIFIC PLATE & FLANGES ASSEMBLY/ VENTURI, FLOW NOZZLE 3.3 FLOW SWITCH 3.4 ELECTROMAGNETIC FLOW METER 3.5 VORTEX FLOW METER 3.6 MASS (CORIOLIS) FLOW METER 4 LEVEL INSTRUMENTS 4.1 LEVEL GAUGE (MAGNETIC & REFLEX TYPE) 4.2 LEVEL SWITCH (CONDUCTIVITY TYPE) LEVEL SWITCH (CAPACITANCE/ RF TYPE) 4.3 4.4 LEVEL SWITCH (TUNING FORK/ROD TYPE) 4.5 LEVEL SWITCH (FLOAT TYPE) 4.6 LEVEL SWITCH/ TRANSMITTER (DISPLACER TYPE) 4.7 LEVEL SWITCH/ TRANSMITTER (ULTRASONIC TYPE) 4.8 LEVEL SWITCH/ TRANSMITTER (RADAR TYPE) 4.9 LEVEL SWITCH TRANSMITTER (NUCLEONIC TYPE) 5 CONTROL VALVES AND ACCESSORIES 5.1 CONTROL VALVE ENGINEERING SPECIALTIES, MICRO-PRECSION, INSTRUMENTATION LTD, UNICONTROL, EMERSON IFM, KOBOLD, MOBREY, KHRONE MARSHALL YOKOGAWA, EMERSON (ROSEMOUNT), FORBES-MARSHALL, ENDRESS & HAUSER, HONEYWELL, ABB EMERSON (MICRO-MOTION), FORBES-MARSHALL, YOKOGAWA, ENDRESS & HAUSER, VORTEX INSTRUMENTS EMERSON (ROSEMOUNT), YOKOGAWA, FORBES-MARSHALL, ENDRESS & HAUSER CHEMTROL, MOBREY (EMERSON), FORBES MARSHALL, SOLARTRON, HI-TECH (LEVELSTAT), WAAREE INSTRUMENT (VEGA) CHEMTROL, ENDRESS & HAUSER, PEPPERAL & FUCHS VEGA, ENDRESS & HAUSER, SAPCON, P&F, NIVO CONTROL, TRINITY TOUCH CHEMTROL (VEGA), ENDRESS & HAUSER, PEPPERAL & FUCHS, SIEMENS, TRINITY TOUCH, SOLATRON EMERSON, FORBES MARSHALL, SOLON, V-AUTOMAT, WAAREE EMERSON, CHEMTROLS (ECKARD), SOLARTRON, MASONIELAN, OM CONTROL SICK, ENDRESS & HAUSER, FORBES-MARSHALL, SIEMENS (MILTRONICS), PEPPERAL & FUCHS SICK, EMERSON (ROSEMOUNT), ENDRESS & HAUSER, FORBESMARSHALL, SOLARTRON, PEPPERAL & FUCHS, SIEMENS CONCORD INTERNATIONAL (DR. BERTHOLD), EMERSON (KAY RAY), E&H, CHEMTROL (THERMOFISHER) FISHER-XOMOX, INSTRUMENTATION LTD, MIL CONTROL, MASCOT, SAMSON CONTROLS, FORBES MARSHALL (ARCA), DEMBLA, KOSO FLUIDS Appendix-6 List of approved vendors. Page 22 of 32 5.2 ELECTRICAL ACTUATOR 5.3 PNEUMATIC ACTUATOR 5.4 5.5 ELECRO-HYDRAULIC ACTUATOR SELF-REGULATING PRESSURE CONTROL VALVE 5.6 I/P CONVERTERS 5.7 PNEUMATIC POSITIONER 5.8 ELECTRO-PNEUMATIC POSITIONER 5.9 ELECTRO-PNEUMATIC POSITIONER (SMART) 5.10 SOLENOID VALVE 5.11 AIR FILTER REGULATOR 5.12 FITTINGS CABLES 6 6.1 PVC CONTROL COPPER CABLES 6.2 THERMOCOUPLE, COMPENSATING CABLES, PTFE CABLES 6.3 LOAD CELL CABLE 6.4 INSTRUMENTATION, SCREENED, CO-AXIAL AND SPECIAL CABLE AUMA, LIMITORQUE, BERNARD, BECK, ROTORK, KOSO-REXA FISHER-XOMOX, INSTRUMENTATION LTD, MIL CONTROL, MASCOT, SAMSON CONTROLS, FORBES MARSHALL (ARCA), DEMBLA, KOSO FLUIDS REINEKE, VOITH, OM CONTROL SAMSON CONTROLS, FORBES MARSHALL, INSTRUMENTATION LTD, FISHER-XOMOX FORBES MARSHALL (MOORE PRODUCTS), ABB, EMERSON, HONEYWELL, BELLS, MARSH BELLOFRAM INSTRUMENTATION LTD, SMC, DRESSER INDUSTRIES (MASONEILAN), SAMSON CONTROLS, FORBES MARSHALL (ARCA), KOSO CONTROL, ABB, MASCOT,DEMBLA, YOUNGTECH CO LTD. FISHER-XOMOX, SIEMENS, MIL CONTROL, SAMSON CONTROLS, INSTRUMENTATION LTD, FORBES MARSHALL (ARCA), YAMATAKE, ABB, YOUNGTECH CO LTD. ABB, YOUNGTECH, METSO, SAMSON MAC (ARDEE), HERION, ROTEX, SCHRADER – SCHOVILL, ASCO, YOUNGTECH CO LTD. SHAVO-NORGREN, MARSHBELLOFRAM, PLACKA, SCHRADERSCHOVILL, MASCOT, YOUNGTECH CO LTD. SWAGELOK, HYLOK, PARKER TOSHNIWAL CABLES, BELDEN, LAPP CABLES, M.E,M INDUSTRIES, KOLKATA, UNIVERSAL CABLES, SATNA, DELTON, BROOKS CABLES TOSHNIWAL CABLES, PARAMOUNT CABLES, MEM INDUSTRIES, KOLKATA, UDEY PYRO-CABLES, BROOKS CABLES, BELDON, LAPP CABLES HBM, SIEMENS, FLINTEC, SARTORIUS MECHETRONICS, VISHAY TRANSDUCERS (SENSOTRONICS, TEDIA, BLH), PRECIA- MOLEN, RICE LAKE, SCHENCK TOSHNIWAL CABLES, DELTON, FINOLEX CABLES, LAPP CABLES, Appendix-6 List of approved vendors. Page 23 of 32 MEM INDUSTRIES, UNIVERSAL CABLES, BROOKS CABLES, BELDEN B. CONTROL ROOM INSTRUMENTATION 7.1 DISTRIBUTED CONTROL SYSTEM (DCS) DCS FOR POWER PLANT APPLICATION DAS 7.2 7.3 7.4 7.5 PROGRAMMABLE LOGIC CONTROLLERS DIGITAL INDICATOR 8.1 GAS ANALYSERS YOKOGAWA, HONEYWELL, EMERSON BHEL, SMAR-LAXONS, EMERSON, INSTRUMENTATION LTD. YOKOGAWA, EUROTHERM, EMERSON, HONEYWELL, NATIONAL INSTRUMENTS REFER AUTOMATION LIST. PEPL, YOKOGAWA, MICRO CONTROLS, MASIBUS, LECTROTEK, RADIX, PANTECH, TOSHNIWAL 7.6 PROGRAMMABLE DIGITAL OMRON, MCIH, YIL, ABB, INDICATOR EUROTHERM 7.7 BAR GRAPH INDICTOR MASIBUS INSTRUMENTS, ABB YOKOGAWA, LECTROTEK, PANTECH, MCIH 7.8 RECORDERS (CHART LESS) EUROTHERM, YOKOGAWA, HONEYWELL, ABB, BRAIN CHILD 7.9 MICROPROCESSOR BASED YOKOGAWA, SIEMENS, CONTROLLER (WITH BAR GRAPH HONEYWELL, EUROTHERM DISPLAY & DUAL LOOP) FORBES MARSHALL, TOSHIBA, ABB 7.10 PID CONTROLLER MCS, MCIH, RADIX, CHINO, YOKOGAWA, ABB, HONEYWELL 7.11 DIGITAL SCANNERS RADIX, MICRO CONTROLS SYSTEM, MASIBUS INSTRUMENTS, PEPL 7.12 DC POWER SUPPLY UNIT APLAB, PHOENIX, P&F, MTL, ANURADHA, ELNOVA, ALLEN BRADLY (ROCKWELL), OSNA, OMRON 7.13 AUTO MANUAL STATION YOKOGAWA, MASIBUS, FORBES MARSHALL, MTL, EUROTHERM, HONEYWELL, PANTECH 7.14 IS INTERFACE/ ZENNER PEPPERL & FUCHS, MTL, RS BARRIER COMPONENT 7.15 SIGNAL ISOLATORS PEPPERL & FUCHS, MTL, YOKOGAWA, FORBES MARSHALL (PROTECH), PHOENIX, OSNA, RADIX, MASIBUS, PANTECH 7.16 ANNUNCIATION SYSTEM (LED IIC, MINILEC, DIGICONT, MTL, BETA TYPE ONLY) INSTRUMENTS, PROCON 7.17 INSTRUMENT PANELS RITTAL, PYROTECH, INSTRUMENTATION LTD 7.18 TOTALIZER MASIBUS, PEPL, LECTROTEK, ABB, MCIH, YOKOGAWA INDIA LTD. C. ANALYTICAL/ SPECIAL INSTRUMENTS ABB (H&B), EMERSON, SIEMENS, YOKOGAWA INDIA LTD, CHEMTROL (SICK MAIHAKL), SERVOMAX Appendix-6 List of approved vendors. Page 24 of 32 8.2 GAS DETECTORS 8.3 CALORIFIC VALUE (CV) ANALYZERS MOISTURE ANLYZERS (NUCLEONIC) 8.4 8.5 8.6 8.7 8.8 CROWCON, MSA, DRAGGER, BW TECHNOLOGIES, INDUSTRIAL SCIENTIFIC CORPN.- USA, REIKEN KAIKI REINEKE, UNION, YOKOGAWA DISSOLVED O2 /PH/ CONDUCTIVITY METER/ TRANSMITTER IR TYPE MOISTURE ANALYZER FLAME DETECTOR VIBRATION SENSORS & MONITORS A. TURBOVISORY SYSTEM B. VIBRATION SYSTEM AS PER API-670 COMPLIANCE B. FOR OTHER APPLICATIONS 8.9 OPACITY /DUST CONCENTRATION METER 9 WEIGHING SYSTEMS 9.1 STATIC RAIL WEIGH-BRIDGE 9.2 IN-MOTION RAIL WEIGHING SYSTEMS CONCORD INTERNATIONAL (DR. BERTHOLD), EMERSON (ANALYTICAL), SICK, THERMOFISHER (MOLA) EMERSON (ANALYTICAL), FORBES MARSHALL (POLYMETRON), YOKOGAWA, ABB, E&H MOISTECH, NDC (EMC), CHEMTROL HONEYWELL, DURAG INSTRUMENTS, YAMATAKE, ENDEE BENTLEY NEVADA, SHINKAWA (FORBES- MARSHALL) BENTLEY NEVADA, SHINKAWA (FORBES- MARSHALL), VIBROMETER, SUJYOTI (SKF), PROVIB-TECH, SPM, IRD MECH ANALYSIS ROCKWELL, MASIBUS, IFM, UNIVERSAL, SPM CODEL (FORBES MARSHALL), DURAG, EMERSON, LAND, GE SENSING, CHEMTROL M/S SCHENCK PROCESS INDIA LTD. M/S STRATEGIC WEIGHING SYSTEMS LTD. (SWSL) M/S SARTORIUS MECHATRONICS INDIA PVT. LTD. M/S WEIGHLOAD TECHNOLOGIES PVT. LTD. (PIVOTEX, S-E-G, TAMTRON) M/S METTLER-TOLEDO INDIA PVT. LTD. M/S ACME AUTOMATION PVT. LTD. M/S IPA PVT. LTD. M/S SCHENCK PROCESS INDIA LTD. M/S STRATEGIC WEIGHING SYSTEMS LTD. (SWSL) M/S METTLER-TOLEDO INDIA PVT. LTD. M/S WEIGHLOAD TECHNOLOGIES PVT. LTD. (PIVOTEX, S-E-G, TAMTRON) M/S MERIDIAN ENGINEERS, AUSTRALIA ( M/S ACME AUTOMATION PVT. LTD.) M/S AMTAB, SWEEDEN Appendix-6 List of approved vendors. Page 25 of 32 9.3 ROAD WEIGH BRIDGE 9.4 HOPPER WEIGHING/ BATCH WEIGHING SYSTEM 9.5 BELD WEIGHER & WEIGH FEEDER 9.6 CRANE WEIGHING SYSTEM (TOTAL SYSTEM INCLUDING LOAD CELLS, SUMMATION/ JUNCTION BOX, LOAD CELL CABLE AND WEIGHING ELECTRONICS ETC.) M/S WEIGH WELL, U.K M/S SCHENCK PROCESS INDIA LTD. M/S STRATEGIC WEIGHING SYSTEMS LTD. (SWSL) M/S ASHBEE SYSTEMS PVT. LTD. M/S METTLER-TOLEDO INDIA PVT. LTD. M/S WEIGHLOAD TECHNOLOGIES PVT. LTD. (PIVOTEX, S-E-G, TAMTRON) M/S SARTORIUS MECHATRONICS INDIA PVT. LTD. M/S ACME AUTOMATION PVT. LTD M/S IPA PVT. LTD. M/S ELDIGI MEASUREMATICS PVT. LTD.- MUMBAI M/S SCHENCK PROCESS INDIA LTD. M/S SARTORIUS MECHATRONICS INDIA PVT. LTD. M/S SIEMENS LTD. M/S STRATEGIC WEIGHING SYSTEMS LTD. (SWSL) M/S TRANSWEIGH INDIA LTD. M/S KISTLER-MORSE AUTOMATION LTD. M/S PRECIA MOLEN INDIA LTD. M/S METTLER-TOLEDO INDIA PVT. LTD. M/S ACME AUTOMATION PVT. LTD M/S IPA PVT. LTD. M/S ELDIGI MEASUREMATICS PVT. LTD.- MUMBAI M/S SCHENCK PROCESS INDIA LTD. M/S TRANSWEIGH INDIA LTD. M/S KRISTLER-MORSE AUTOMATION LTD M/S PRECIA MOLEN INDIA LTD M/S POWER BUILD LIMITED M/S SARTORIUS MECHATRONICS INDIA PVT. LTD. M/S WEIGHLOAD TECHNOLOGIES PVT. LTD. (PIVOTEX, S-E-G, TAMTRON) M/S PROCON ENGINEERING LTD. (M/S RAMAN INSTRUMENTS PVT. LTD.) M/S ACME AUTOMATION PVT. LTD M/S DOSATEC, SWITZERLAND M/S ABB LIMITED M/S VISHAY TRANSDUCERS INDIA LTD. M/S SCHENCK PROCESS INDIA LTD. M/S WEIGHLOAD TECHNOLOGIES PVT. LTD. (PIVOTEX, S-E-G, TAMTRON) M/S TECHNICAL WEIGHING Appendix-6 List of approved vendors. Page 26 of 32 SERVICES-USA M/S ELDIGI MEASUREMATICS PVT. LTD.- MUMBAI M/S EILON ENGINEERING IND. WEIGHING SYSTEMS LIMITED - UK M/S EHP WAEGETECCHINK GMBH GERMANY 9.7 LOAD CELL AND ACCESSORIES M/S HBM INCLUDING MOUNTING KIT, M/S SIEMENS LOAD CELL SUMMATION/ M/S FLINTEC JUNCTION BOX AND LOAD M/S SARTORIUS MECHETRONICS CELL CABLE ETC. M/S VISHAY TRANSDUCERS (SENSOTRONICS, TEDIA, BLH) M/S PRECIA- MOLEN M/S RICE LAKE M/S SCHENCK 9.8 PLAT FORM SCALES M/S SCHENCK PROCESS INDIA LTD. M/S SARTORIUS MECHETRONICS INDIA PVT. LTD. M/S PRECIA- MOLEN INDIA LTD. M/S METTLER-TOLEDO INDIA PVT. LTD. M/S ACME AUTOMATION PVT. LTD M/S ESSAE TEROKA LTD. 9.9 BAGGING SCALE M/S TRANSWEIGH INDIA LTD. M/S POWER BUILD LIMITED M/S JASUBAHI MATERIAL HANDLING SYSTEMS PVT. LTD. M/S INDUS CONTROL AND AUTOMATION PVT. LTD. 9.10 WEIHING ELECTRONICS/ M/S SCHENCK PROCESS INDIA LTD. CONTROLLER / INDICATOR M/S SARTORIUS MECHATRONICS INDIA PVT. LTD. M/S STRATEGIC WEIGHING SYSTEMS LTD. (SWSL) M/S PRECIA MOLEN INDIA LTD M/S FLINTEC SALES PVT. LTD. M/S EUROTHERM DEL INDIA LTD. M/S TRANSWEIGH INDIA LTD. M/S RICE LAKE M/S GSE SCALES SYSTEMS M/S RED LION CONTROLS M/S VISHAY TRANSDUCERS INDIA LTD. M/S ASHBEE SYSTEMS PVT. LTD. 9.11 WEIGHT TRANSMITTER M/S SARTORIUS MECHATRONICS INDIA PVT. LTD. M/S FLINTEC SALES PVT. LTD. M/S SCHENCK PROCESS INDIA LTD. M/S PRECIA MOLEN INDIA LTD 9.12 AC/DC DRIVES & CONTROLLERS AS PER BSP ELECTRICAL (FOR WEIGHING APPLICATIONS) PREFERRED MAKE. 9.13 TRACK SWITCHES M/S STRATEGIC WEIGHING SYSTEMS LTD. (SWSL) M/S RAILAC M/S SENLOGIC Appendix-6 List of approved vendors. Page 27 of 32 9.14 LOAD CELL/ WEIGH LINE RAIL SENSORS AND ELECTRONICS FOR IN-MOTION RAIL WEIGH BRIDGES M/S R.K.ENGINEERING WORKS M/S SCHENCK PROCESS INDIA LTD. M/S METTLER-TOLEDO INDIA PVT. LTD. M/S WEIGHLOAD TECHNOLOGIES PVT. LTD. (PIVOTEX, S-E-G, TAMTRON) M/S MERIDIAN ENGINEERS (M/S ACME AUTOMATION PVT. LTD.) M/S AMTAB – SWEEDEN M/S WEIGH WELL - UK M/S STRATEGIC WEIGHING SYSTEMS LTD. (SWSL) M/S SCHENCK PROCESS INDIA LTD. M/S METTLER-TOLEDO INDIA PVT. LTD. M/S WEIGHLOAD TECHNOLOGIES PVT. LTD. (PIVOTEX, S-E-G, TAMTRON) M/S MERIDIAN ENGINEERS (M/S ACME AUTOMATION PVT. LTD.) M/S AMTAB – SWEEDEN M/S WEIGH WELL - UK XVII. VALVES 1 C.S. GATE/GLOBE VALVE A. (NON-IBR- FOR ALL SIZES AND RATINGS) 2 BUTTERFLY VALVE M/S B.D.K. ENGG. INDUSTRIES LTD. HUBLI, M/S BHEL, TIRUCHIRAPALLI, M/S FOURESS ENGG. (INDIA) LTD, AURANGABAD, M/S K.S.B. PUMPS LTD, KOLKATA, M/S LARSEN & TOUBRO LTD (AUDCO), CHENNAI, M/S LEADER VALVES LTD, JALANDHAR, M/S OSWAL INDUSTIRES LTD, AHMEDABAD M/S ADVANCE VALVES PVT LTD., NOIDA, M/S AVCON CONTROL PVT LTD, MUMBAI, (FOR ACTUATOR OPERATED VALVES), M/S B.D.K. ENGG. INDUSTRIES LTD, HUBLI. M/S CRANE PROCESS FLOW TECH(INDIA) LTD, PUNE, M/S FOURESS ENGG. (INDIA) LTD, AURANGABAD, M/S INTER VALVES (PVT) LTD. PUNE, M/S LARSEN & TOUBRO LTD (AUDCO), CHENNAI, M/S TYCO VALVES, BARODA, Appendix-6 List of approved vendors. Page 28 of 32 3 BALL VALVES 4 CI SLUICE GATE VALVES A. FOR ALL SIZES AND RATINGS M/S VIRGO ENGINEERS LTD, PUNE M/S B.D.K. ENGG. INDUSTRIES LTD, HUBLI, M/S DELVAL FLOW CONTROL PVT LTD, PUNE M/S FISHER XOMOX SANMAR, TRICHURAPALLI. M/S FLOWCHEM IND., AHMEDABAD, M/S FOURESS ENGG. (INDIA) LTD, AURANGABAD, M/S HABONIM VAAS AUTOMATION PVT LTD, CHENNAI, M/S INTER VALVES, PUNE. M/S LARSEN & TOUBRO LTD (AUDCO), CHENNAI, M/S OSWAL INDUSTIRES LTD, AHMEDABAD, M/S VIRGO ENGINEERS LTD, PUNE M/S B.D.K. ENGG. INDUSTRIES LTD, HUBLI, M/S CALSENS PRIVATE LTD, KOLKATA, M/S G.M. DALUI & SONS, HOWRAH, M/S H. SARKER & CO., KOLKATA, M/S HAWA ENGINEERS LTD, AHMEDABAD, M/S KIRLOSKAR BROTHERS, NAGPUR, M/S LEADER VALVES LTD, JALANDHAR, M/S VENUS PUMP & ENGG. WORKS, HOWRAH, MS/ NETA VALVES PVT LTD, JALANDHAR B. FOR SIZES UP TO NB 100 MM M/S RONEX ENGG. COMPANY, & PN 16 RATINGS KOLKATA, M/S UPADHYAYA VALVE MANUF. PVT LTD, KOLKATA, M/S STEAM & MINING INDUSTIRES, KOLKATA. 5 PLUG VALVE 6 COCK VALVE FOR GAS APPLICATIONS CHECK/NON-RETURN VALVE 7 (VENDORS APPEARING UNDER ’A’ SHALL BE ELIGIBLE FOR ’B’ ALSO) M/S B.D.K. ENGG. INDUSTRIES LTD, HUBLI, M/S FISHER XOMOX SANMAR, LTD, CHENNAI, M/S HABONIM VAAS AUTOMATION PVT LTD, CHENNAI, M/S LARSEN & TOUBRO LTD (AUDCO), CHENNAI M/S LARSEN & TOUBRO LTD (AUDCO), CHENNAI M/S ADVANCE VALVES PVT LTD, NOIDA, Appendix-6 List of approved vendors. Page 29 of 32 8 FABRICATED GATE VALVE 9 PISTON VALVE 10 VALVES FOR STEAM APPLICATION A. FOR ALL SIZES AND RATINGS B. FOR SIZES UP TO 50 MM AND CLASS # 150 RATINGS 11 KNIFE EDGE GATE VALVE 12 NON-FERROUS VALVE M/S B.D.K. ENGG. INDUSTRIES LTD, HUBLI, M/S FOURESS ENGG. (INDIA) LTD, AURANGABAD, M/S INTER VALVES (PVT) LTD, PUNE, M/S K.S.B. PUMPS LTD, KOLKATA. M/S LARSEN & TOUBRO LTD (AUDCO), CHENNAI, M/S LEADER VALVES PVT LTD, JALANDHAR. M/S OSWAL INDUSTRIES LTD., AHMEDABAD M/S FOURESS ENGG. (INDIA) LTD, AURANGABAD. M/S LARSEN & TOUBRO LTD (AUDCO), CHENNAI, M/S ZIMMERMANN & JANSEEN, DUREN, GERMANY. M/S SPIRAX MARSHALL LTD, NAGPUR, M/S UNI-KLINGER LTD, PUNE M/S B.D.K. ENGG. INDUSTRIES LTD, HUBLI, M/S OSWAL INDUSTIRES LTD, AHMEDABAD, M/S LARSEN & TOUBRO LTD (AUDCO), CHENNAI, M/S FOURESS ENGG. (INDIA) LTD, AURANGABAD. M/S K.S.B. PUMPS LTD, KOLKATA, M/S BHEL, TRICHURAPALLI, M/S LEADER VALVES LTD, JALANDHAR M/S NETA VALVES PVT LTD, JALANDHAR, HAWA VALVES (INDIA) PVT. LIMITED, MUMBAI M/S M.H. VALVES PVT LTD, AHMEDABAD. (VENDORS APPEARING UNDER ‘A’ SHALL BE ELIGIBLE FOR ‘B’ ALSO) M/S ENERGO ENGG. NOIDA, DELHI M/S FOURESS ENGG. (INDIA) LTD, AURANGABAD. M/S ORBINOX INDIA PVT LTD, COIMBATORE. M/S VASS IND. PVT LTD, CHENNAI M/S LEADER VALVES LTD, JALANDHAR MS/ NETA VALVES PVT LTD, JALANDHAR M/S SANT VALVES PVT LTD, JALANDHAR Appendix-6 List of approved vendors. Page 30 of 32 M/S ZOLOTO IND., JALANDHAR XVIII. AUTOMATION & INFORMATION SYSTEM 1. PLC 2. 3. COMPUTER (SERVICES) COMPUTER (PC/ WORK STATIONS/ LAP TOP) DOT MATRIX PRINTER LASER/ INKJET PRINTER, SCANNERS LCD PROJECTORS 4. 5. 6. 7 8 9 9.1 9.2 9.3 9.4 9.5 10 11 ABB, GE-FANUC, ROCKWELL AUTOMATION, SIEMENS, SCHNEIDER IBM, HP, SUN IBM, HP-COMPAQ, LENOVO, DELL, HP EPSON, TVSE HP LARGE FORMAT DISPLAYS/ MONITORS (LCD, 42’’ OR BIGGER) DISPLAY WALLS (DLP/ LCD) NETWORK EQUIPMENT ACTIVE COMPONENTS – SWITCHES & ROUTERS ACTIVE COMPONENTS – OTHERS (INCLUDING FO/UTP MEDIA CONVERTERS, MODEMS ETC.) PASSIVE COMPONENTS – CABLING (INCLUDING FO CABLE, UTP CABLE ETC.) PASSIVE COMPONENTS – RACKS INDUSTRIAL GATE ETHERNET SWITCHES COMPUTER FURNITURE UPS/ CVT XIX. CONVEYOR BELTS 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. M/s Phoenix Yule Limited. M/s Mercury Rubber Mills M/s Forech India Limited M/s NRC Industries Limited M/s Oriental Rubber Industries Ltd. M/s Anil Rubber Mills Pvt. Ltd. M/s Sempertrans Nirlon Ltd. M/s Hindustan Rubbers (Silvasa) M/s Northland Rubber Mills M/s Jhonson Rubber Industries HITACHI, CANON, PANASONIC, SONY, SHARP, HP LG, HP, NEC, SAMSUNG, SONY, PANASONIC BARCO, MITSUBISHI ELECTRIC CISCO ALLIED TELESYS/ TELESYN, RAD, ZYXEL LUCENT, AMP, SYSTIMAX, MOLEX, R&M APW PRESIDENT, RITTAL, KRONE HIRSCHMANN, SIXNET GODREJ, METHODEX, WIPRO AS PER PREFFERED MAKE LIST OF ELECTRICAL. … … … … … … … … … … All grades – M24, HR & SHR -do-do-do-do-do-do-do-doOnly for M-24 Grade. Appendix-6 List of approved vendors. Page 31 of 32 XX. FIRE FIGHTING EQUIPMENT. 1. 2. FIRE ISO – 9001-2000 M/S KANADIA FYR EXTINGUISHERS PVT.LTD. AND MODULARS. MUMBAI. Carbon Monoxide Detector, Pocket Size, Micro processor based. (As per approved specification). a) Range – 0 to 1500 ppm & above, but not more than 2000 ppm. M/s Respo Products M/s Detection Instrument Ltd. M/s Joseph Leslie Draeger. M/s MSA M/s Industrial Scientific M/s Respo Products M/s ABN India (MSA) M/s Joseph Leslie Draeger M/s Detection Instruments Ltd. M/s BW Technologies M/s Ambetronics. b) Range – 0 to 500 ppm & above, but not more than 1000 ppm. XIX. 1. FYTER POLYMER CHUTE LINER. POLYMER LINER. CHUTE - M/S JYOTI CERO JAMSHEDPUR. RUBBER, *** Appendix-6 List of approved vendors. Page 32 of 32 STEEL AUTHORITY OF INDIA LIMITED BHILAI STEEL PLANT GENERAL SPECIFICATION FOR PREFFERED MAKES (GS – 13) MECON LIMITED RANCHI – 834002 No. MEC/S/1901/11/38/0/00/00/F1889/R2 JULY, 2007 General Technical Specification CONTENTS SL. NO. 01 PREAMBLE 02 FLUID SYSTEM 2 03 VENTILATION, AIR CONDITIONING AND AIR 9 DESCRIPTION PAGE NO. 1 POLLUTION CONTROL EQUIPMENT 04 HANDLING & HOISTING EQUIPMENT 11 05 REPAIR & MAINTENANCE FACILITIES 16 06 ELECTRICAL 17 07 INSTRUMENTATION 25 08 FIRE PROTECTION SYSTEM 30 09 BOF GCP EQUIPMENT 30 10 INFORMATION SYSTEM 32 11 FLUID SYSTEMS & PIPING ENGG 34 (LUBRICATION & HYDRAULICS) © 2007 MECON Limited All rights reserved Preferred Makes Page 1 of 1 GS-13 General Technical Specification 01. PREAMBLE This document “PREFERRED MAKES OF EQUIPMENT AND SUPPLIES” is a part of the tender specification for various packages of BHILAI STEEL PLANT. The makes of various equipment and supplies in respect of imported/indigenous equipment/components/materials are listed out in this document. It is essential that the equipment/component/materials to be supplied from imported/indigenous sources by the Tenderer will be of any one of the makes listed against that particular equipment/ component/material in this documents.. In case the Tenderer/ Contractor intends to substitute any particular make of equipment / components/ materials by a make other than that listed in this document, the Tenderer shall clearly bring out the same in his tender along with justification and indicate the alternative makes offered by him. It will be prerogative of the Purchaser to accept or reject the alternative makes so offered. © 2007 MECON Limited All rights reserved Preferred Makes Page 1 of 37 GS-13 General Technical Specification 01 FLUID SYSTEM 01.01 Water Supply Facilities Sl. No. Item Description 1 Horizontal Centrifugal Pumps : Kirloskar Brothers, KSB, Beacon Weir, Khimline, Jyoti, Sintech, Ghaziabad. 2 Vertical Turbine Pumps : Kirloskar Brothers, Voltas, WPIL, Jyoti, 3 Vertical Wet Pit Type Pumps : SU Motors, Kishore Pumps, Kirloskar Brothers, KSB. 4 Submersible Pumps : KSB, SU Motors, Kirloskar Brothers, Kishore Pumps, Darling, Beacon Weir. 5 Slurry Pump : Akay, Sam Engg., MBE, KBL, KSB Pumps, WARMAN. 6 Dosing Pump : Shapo Tools, Asia LMI (Madras), Positive Metering Pumps, Toshniwal, Milton Roy India. 7 Cooling Towers : PCTPL, Shri Ram Tower Tech, Gammon, Himgiri, Southern Cooling Tower, BDT, GEA 8 Pressure Filters : Thermax, Ion-Exchange, Resin India, Driplex, Doshion, VA Tech Wabag, UEM, Aquatech 9 Sluice Gates : Jash Engineering, IVPL 10 Travelling Water Screen : Macmet, Triveni, Otokiln, Mecgale (Nagpur), General Mechanical 11 Sludge Scrapper : Triveni, Neo – Parisrutan, Mata India, Geomiller 12 Fire Hydrants : New Age Industries, Steelage Industires, ASCO, Strumech, Vijay Fire, Zenith 13 Basket Strainers : Filteration Engrs, J.N Marshall, Masturlal Fabrication , ARF Engg, Purolator Filters, ABB, Filters Mfd India 14 Duplex Strainers : Filteration Engrs., Otokiln, Superflo 15 Rubber Dismantling Joints : BDX, CORI Engineers, D.Wren, 16 Diesel Engine 17 Softening & DM Plant 18 R O Plants 19 Effluent Treatment Plant : 20 Drinking water Treatment Plant : UEM India, VA Tech, GEA Energy Systems, Driplex Water Engg , Triveni, 21 Basalt Liners : DEMECH, Vidyut Green Bank, Enviro Abrasian, Garden © 2007 MECON Limited All rights reserved Manufacturers : : : Cummins/Ashok Layland/Ruston Doshi / Resin India / Thermax / Thermax Cullinyan / VA Tech / Ion Exchange /Triveni / GEA Energy Systems/ Driplex Water Engg, Triveni, UEM India, VA Tech, GEA Energy Systems, Ion Exchange, Driplex Water Engg, Triveni, UEM India, VA Tech, GEA Energy Systems, Triveni, Preferred Makes Page 2 of 37 GS-13 General Technical Specification Sl. No. Item Description 22 Oil Skimmer : JVM Engg. 23 Plate Heat Exchangers : Alfalaval, GEA Ecoflex, IDMC 24 Surge Tanks : Anup Engg., Zenith Erectors, Haldia., Perfect Engg., Sakthi Hitech 25 C.I. Valves (gate, globe, NRV) : Kirloskar Brothers, Steam & Mining, IVPL, AV Valves, Shiv Durga, BDK, Fouress. 26 CS Valves (gate, NRV) : Audco, Fouress, BHEL, Sakhi, KSB, Steam & Mining, BDK, Kirloskar, Virgo 27 Plug Valves : Audco- L&T, Vass Ind., Xomox, Virgo, BDK, Steam & Mining. 28 Ball Valves : Audco, KSB, AL Saunders, Xomox, Virgo, BDK, Virgo , 29 GM Valves : Leader, Steam & Mining, NECO, Upadhyay Valves, Kalpana Valves 30 Butterfly Valves (Manually & electrically operated) 31 Diaphragm Valves 32 Float Valve 33 Control Valve 34 Solenoid Valve 35 Air Release Valve 36 Pressure Reducing Valve 37 Strainer/Filter 38 Electric Actuators 39 Rotory Pneumatic Actuators 40 Hoses 41 Pipes a) MS/GI Manufacturers Reach Ship Builders & Engg. b) DI : : : : : : : : : : : : : L&T, Fouress, Kirloskar Brothers, IVPL, VIRGO, AL Saunders, Steam & Mining, Keystone, BDK, XOMOX. AL Saunders, Fluid System, BDK , Steam & Mining. Leader, IVPL, IM Engineers, Steam & Mining. BHEL, L&T, Fouress, IL, MIL Controls, NECO Scharbet, Darling Rotex, Sicmag, Scharder, NECO INDFOS, Eastern Pneumatic, Bluestar, AVCON, ASCO, Mercury Shiva Durga, IVPL, IM Engineers, Steam & Mining, Schroder Duncum, Fluid Line Valves. JNM, Fouress, Bestobell, IL, Mazda, Nirmal Ind., Forbes Marshal Otokiln, Superflo, Triveni Plenty, Filter Mfg. Ind., Purolator, Filteration Engineers Beacon Rotork, Auma, Marsh Engineers, Keystone, Limitorque, Antrieb, IL, Palghat AL Saunders, Xomox, EL-O-Matic, Virgo, L&T, Flocon, Precision Processing Equipt. Co. Aeroflox/Markwel/Senior Flexonics, Inalsa, Teksons SAIL/TATA/Jindal/Zenith/Man/SAW/Surindra/Welspun/Prak esh Electro Steel Casting 42 RCC Pipes & Fittings : SUR Industrial Pipes, Hind Ceramics, Indian Hume Pipes, Daya Cuncrching. 43 HDPE Pipes & : EMCO, KWH Heliplastic Polyolefins, Oriplast © 2007 MECON Limited All rights reserved Preferred Makes Page 3 of 37 GS-13 General Technical Specification Sl. No. 01.02 Item Description Manufacturers Fittings 44 PVC Pipes & Fittings : Oriplast, Finolex, Bharat Pipe & Fittings, Supreme Industries. 45 SS Pipes / SS Fittings : Heavy Metal Tubes, Nobel Tubes, Rajendra Mech. Ind., Vitrag, SAIL, Poonam Enterprises, N.L.Hazra, M.S.Fittings 46 Seamless, Stainless Steel Pipes/Tubes : Choksy Tubes, MJ Patel, Nagardas Kanji, Poonam Enterprises, Sandulk Asia, Noble Tubes, Allied Steel, SAIL, Maharastra Seamless (P) Ltd, 47 Fittings for the above Pipes/Tubes : EBY Ind., High-Tech, Hydro technic, Hydro-Air Engg., Project Toolings, Shivananda, M.J.Patel, Nobles Tubes, Allied Steel, Poonam Enterprises, N.L.Hazra, M.S.Fittings 48 Wrapping & Coating for pipes : Rustech Products, HOTACO, IWL, M P Tar Products 49 Chemical Dosing System Hindustan Dorr Oliver, Chembonddrewtreat ltd., NALCO Tellabs Chemicals, Valves For Fuel Gas, Steam, Nitrogen, LPG & Compressed Air Facilities Item Description Manufacturers C.I. Valves for Fuel Gas & Compressed Air (gate, globe, NRV) : Kirloskar Brothers, GM Dalui, Steam & Mining, H.Sarker, IVPL, AV Valves, Leader, Associated tooling, BDK, Kalpana Valves CS, FS, SS Valves for Steam, Feed Water, & LPG (Gate, Globe, NRV) : L&T (Audco Div), Fouress, BHEL, KSB, GM Dalui, Leader, BDK, NECO, Associated Tooling, Hawa Egr., Vass Ind, Advance Valves, Kalpana Valves CI, CS, SS & FS Plug Valves : Vass Ind., Xomox, Virgo, BDK, Leader, Steam and Mining, GM Dalui, H.Sarkar, Audco Ball Valves : Audco, Vass Ind, KSB, BDK, Microfinish, Niton,AL Saunders, Xomox, Virgo, United Engineers, Steam & Mining, Hi-Tech B.Valves GM Valves : Bombay Metals, GM Dalui, Leader, NECO, Kalpana Valves © 2007 MECON Limited All rights reserved Preferred Makes Page 4 of 37 GS-13 General Technical Specification 02.03 Butterfly Valves : Audco, Fouress, Kirloskar Brothers, IVPL, Inter Valve, Virgo, AL Saunders, Keystone, BDK, Leader, AVC Engg., Crowley & Ray, Xomox, Tyco, Hi-Tech. Diaphragm Valves : AL Saunders, Fluid System, Leader, BDK, Xomox, Steam & Mining Pressure Control Valve/Pressure Reducing Valve : JNM, Fouress, Bestobell, IL, Mazda, Nirmal Ind., Vanaz, Kosan Metal, Vass Ind., RK Control, Fluid Line, Forbes Marshal, Leader. Large Diameter Goggle Valve : Audco, Fouress, Cimmco, L&T Fabricated Gate Valves : Fouress, Cimmco, Kalpana Valves Safety Relief Valve (Pressure relief Valves) : BHEL, Keystone, Bliss Anand, L&T (Audco Div.), Sempell, Fainger, Leser Valves (P) Ltd., IL, Anderson, Kosan. BECO, Beekay, L&T, Miscellaneous Gas Facility & Compressed Air Equipment Item Description Manufacturers Oxygen Acetylene & LPG Manifolds : Kamrup Industrial Gases, INOX, Titan Engg., BOC, Ramba Hydrogen, Asiatic Oxygen SS Bellows Expansion Joints : Flexican, Flexatherm, SURR Ind., Pressel (Cuttack), BD Engr., Eludyne Engr., SPB, SEPL, PEBI, Lonestar, GBM Mfg., TI Flexible Tube. Centrifugal Gas Booster : Andrew Yule, TLT, James Howden (U.K), Donkin (U.K), Hibhen Twin Lobe Type Booster : Skoda, CKD Kompressors, MD Pneumatics, Demag Delavl, Bryan Donkin Sulzer, Oil & Gas Plant Engg., (Tuthill), Kay International © 2007 MECON Limited All rights reserved Preferred Makes Page 5 of 37 GS-13 General Technical Specification Gas/Air Compressors : Ingersoll Rand, Atlas Copco, KG Khosla, Kirloskar Pneumatic, Chicago Pneumatic, Mannesman Demag, Eliat, Cooper, Sulzor, Corken (USA) Hoses : Flexican, Gaytri Industrial Corpn., Inalsa, Teksons, Sudeep Industries, Markwell Valves for Oxygen Services: Item Description 1. Manufacturers Non-Ferrous: For Isolation : Bestobell (UK), ETH IRELAND (France), RT Orseal (UK), Truflo (Belgium), Worcestor Controls (UK), Quick Sheet-off Valve : Bestobell (UK), ETH IRELAND (France), RT Orseal (UK), Truflo (Belgium), Worcestor Controls (UK), Moorco, SEBIM : SEVERN (UK), NELES SECK GLOKON (UK), IL (Palghat) Solenoid Valve : AVCON, SEITZ, ROTEX, ASCO Safety Relief Valve (SRV) : KUNKLE (USA), KEYSTONE (USA), BROADY (UK), MOORCO, SEBIM, IL (Palghat) Pressure Regulators (Self regulating with pressure gauge)for Oxygen : ESAB, BOC, Speciality Gases, Kamrup Industrial Gases, Venaz Engineers, Nirmal Ind. Stainless Steel (SS) : Precision Engg., BDK, Niton, Akay, Leader, Audco, Sakhi & Co., KSB Pressure Control Valve (PCV) & Flow Control Valve (FCV) 2. (manual) POWER & ENERGY © 2007 MECON Limited All rights reserved Preferred Makes Page 6 of 37 GS-13 General Technical Specification Item Description Manufacturers Air Drying Uuit : Chemech, Cleanair, Delair, Indcon, Mellcon, Mirch Mirex, Gasoenergy System Pune. Condensate Pumps : KSB, BHEL, Kirloskar Brothers, Mather & Platt, Khimline, Sigma Ejector : BHEL, Weigand, Newfield, Mazda Trap & Strainer for Compressed Air & Steam : Uniklinger, ESCO, JNM, Dryton Greaves, Forbes Marshall, Hawa Engrs., Mazda Electrical : AUMA India, Beacon Rotork Controls, Continental Profiles, Emtork Actuators, Limitorque Pneumatic : Marsh Engg., Keystone, IL, Massoneilan, ELO-MATIC, Virgo, AL Saunder, L&T, Flocan : BHPV, Kaveri, Texmaco, Thermax, Babcock & Wicox, Parkair Engg., Rhine, Universal Heat Exchanger, Godrej, L&T, GEI Godavari, Patel Air Temp., Hindustan Radiaton Control Valves : Blue Star, Fouress Engg., IL, JNM, Mazda, Forbes Marshall Pressure Vessel & Tanks : Beekay Engg., BHPV, ISGEC, Kaveri Engg., TSL, Lloyds Steel, Mukand, Parkair Engg., Grasim Industries, Anup Thermal System, Texmaco, SV Tank, Grasim Industries, Hyderfuel Industries. Thermal Insulation : Hyderapad Industries, Lloyds Insulation, Rockwool, Thermax Heat Tracers, U.P. Twiga Fibreglass. Suction Filters : FMI, KAAF, L&T, Flakt, Autokiln Filter, GEC Alsthom, Filtration Engr., ARF Engg., ABB, Dyna Filter, Purolator Filters, GM Dalui Actuators Heat Exchanger (Shell & Tube Type) © 2007 MECON Limited All rights reserved Preferred Makes Page 7 of 37 GS-13 General Technical Specification 02.04 Pipes & Fittings Facilities. for Water Supply, Gas Facilities, Steam and Compressed Air Item Description Manufacturers SW/SAW, ERW/EFW MS Pipes : SAIL, BHEL, TISCO, Jindal, Ajanta, Zenith, Saw Pipes, Welspun, Man Industries, Surindra Engg., Maharastra Seamless, Indian Seamless, BST, Advance Steel, Good Luck, Indus Tubes, Mukat, Lloyds, Poonam Enterprises, Soor Neogi Koumar. SS Pipes / SS Fittings : Heavy Metal Tubes, Nobel Tubes, Rajendra Mech. Ind., Sterling Supply Agency, Vitrag, SAIL, Poonam Enterprises, N.L.Hazra, M.S.Fittings Seamless, Stainless Steel Pipes/Tubes : Amardeep Steel, Choksy Tubes, MJ Patel, Nagardas Kanji, Poonam Enterprises, Sandulk Asia, MEC Tubes, Nagardas & Kusai, Noble Tubes, Allied Steel, Kamlesh Tube, Menilal & Bro, Uday Tubes, SAIL, Maharastra Seamless (P) Ltd, Imperial Steel, Soor Neogi Koumar. Fittings for the above Pipes/Tubes : EBY Ind., High-Tech, Hydro technic, HydroAir Engg., Project Toolings, Shivananda, M.J.Patel, Nagardas & Kusai, MEC Tubes, Nobles Tubes, Amardeep Steel, Allied Steel, Kamlesh Tube, Menilal & Bros, Poonam Enterprises, N.L.Hazra, M.S.Fittings RCC Pipes & Fittings : SUR Industrial Pipes, Hind Ceramics, Indian Hume Pipes, Daya Cuncrching. HDPE Pipes & Fittings : EMCO, KWH Heliplastic Polyolefins, Oriplast PVC Pipes & Fittings : Oriplast, Finolex, Bharat Pipe & Fittings, Supreme Industries. © 2007 MECON Limited All rights reserved Preferred Makes Page 8 of 37 GS-13 General Technical Specification 03. VENTILATION, AIR CONDITIONING & AIR POLLUTION CONTROL EQUIPMENT Item Description Manufacturers Centrifugal fans for Ventilation : C.Doctor, EFE, AEROVENT, Flow Link, Andrew Yule, RIECO, ISEL, BATLIBOI, Flaktwood, REITZ, ACCEL, Dustven, INDFAN, Centrigugal fans for Dedusting : BHEL, TLT, C.Doctor, Andrew Yule, RIECO, Batliboi, F.Harley, Flaktwood, REITZ, DUSTVEN, ISEL, INDFAN Tube axial fans / Propeller Fans : C.Doctor, EFE, Flow Link, ALMONARD, ACCEL, KHAITAN, AEROVENT, ISEL, INDFAN Panel filter for air : FMI, Clean Filter Industries, EFE, ACCEL, FILTRONIC, FLOWLINK, CADILLAC, C. DOCTOR Air washer : C.Doctor, EFE, FLOW LINK, FHARLEY, ALSTOM, Dustven, BATLIBOI, FMI Man coolers : C.Doctor, Ventura, LM KHAITAN, ALMONARD, FLOWLINK Roof exhauster : C.Doctor, EFE, ACCEL, ALMONARD, FLOWLINK, INDFAN, AEROVENT Window air conditioners : Fedders Lloyd, VOLTAS, Blue Star, ARCTIC, Carrier Aircon, LG, Samsung, HITACHI Packaged air conditioners : VOLTAS, Blue Star, KIRLOSKAR, ACCEL, BATLIBOI, EMERSON, FEDDERS LLOYDS, ROOS TEMPKOOL, ROOTS COOLING © 2007 MECON Limited All rights reserved Preferred Makes Page 9 of 37 ENGINEERS, DUSTVEN, GS-13 General Technical Specification Item Description Manufacturers Packaged chillers : VOLTAS, Blue Star, ALSTOM, Batliboi, ACCEL, FEDDERS LLOYD, KIRLOSKAR, PNEUMATIC Air handling units : VOLTAS, BLUE STAR, ALSTOM, BATLIBOI, PATELS AIR TEMP, ROOTS COOLING Cooling towers : PAHARPUR, MIHIR, ADVANCE, GAMMON INDIA, Southern Cooling Towers Ltd., SHRIRAM TOWER TECH. Refrigerant compressors : VOLTAS, SHRIRAM, ACCEL, BLUE STAR, , Atlas Copco, Kirloskar, HITACHI Cyclones : THERMAX, RIECO, ALSTOM, C.DOCTOR, F.HARLEY, Dustven, EFE Multicyclones : THERMAX, ALSTOM, C. DOCTOR, BATLIBOI, RIECO, F.HARLEY, EFE : THERMAX, ALSTOM, ANDREW YULE, RIECO, C.DOCTOR. F.HARLEY, Dustven, BATLIBOI, FMI : ALSTOM, RIECO, THERMAX, VAI, Dustven, BATLIBOI Wet scrubbers : ALSTOM, THERMAX, BATLIBOI, RIECO, C.DOCTOR, F.HARLEY, EFE, SOIL & ENVIRO SYSTEM Venturi scrubbers : BATLIBOI, THERMAX, RIECO, ALSTOM, Dustven Electrostatic precipitators : ANDREW YULE, VOLTAS, ABB, VAI Bag filters 3 (Cap – 10,000 m /h to 3 80, 000 m /h) Bag filters 3 (Cap –Above 80,000 m /h) Insulation THERMAX, TWIGA, LLOYDS, BAKELITE MALANPUR ENTECH BHEL, HYLAM, Valves for air conditioning : DANFOSS, HONEYWELL, BLUE STAR Vibration isolators : DUNLOP, EMERALD Centrifugal horizontal pumps : KSB, BEACON KIRLOSKAR Horizontal split casing pumps : VOLTAS, BEACON KIRLOSKAR © 2007 MECON Limited All rights reserved Preferred Makes Page 10 of 37 WEIR, WEIR, VOLTAS, KSB, GS-13 General Technical Specification 04. HANDLING & HOISTING EQUIPMENT & COMPONENTS 04.01 Equipment Item Description Manufacturers EOT Crane (Up to 10T capacity) : Armsel, Avon, FAFECO, Mukand, Anupam, Shivpra, Tubrofurguson EOT Crane (Up to 50 T capacity) : HEC, Jessop, Mukand, Hyderabad Ind. Ltd., WMI, FAFECO, Unique, Anupam EOT Crane (Above 50 T capacity) : Jessops, HEC, Mukand, FAFECO, Unique, WMI, . Underslung Cranes (Upto 5t only) Electric Hoists : Armsel, Brady & Morris, Shivpra : Armsel, Shivpra,WH Brady, Brady & Morris, Grip Engrs., Hi-tech, Century Crane Transfer Cars : HEC, L&T, Hyderabad Ind., Engrs, ELECON, TRF Chain Pulley Blocks & hand operated travelling cranes. Shunting Winch : Armsel, Century Cranes, Brady & Morris, Light Lift Ind., Hi-tech, MR Engg. Lifting Equipment : Beekay, HEC, Armsel, Century Cranes, Nirmal Equipments, Mining & MH Equipment, Cyclo transmission Jib Crane : Brady & Morris, Century Cranes, Hi-tech, Grip Engrs., Elite, Light Lifting, Armsel Crawler Mounted Mobile Crane Excavator/ Shovel : TIL, Hyderabad Industries, TATA-P&H : TIL, HEC, Hyderabad Industries, BEML Elevator/Lift : OTIS, OMEGA, Kone, ECE © 2007 MECON Limited All rights reserved Preferred Makes Page 11 of 37 WMI, Mukand, Eqipt GS-13 General Technical Specification 04.02 Mechanical Components/ Equipment Item Description Manufacturers Hooks : Herman Mohta, Free Trading Corporation, Steel Forgings & Engg.. Flexible / Geared coupling : Hicliff, Concord, Wellman, GBM, Alliance, New Allenbery Works,Elecon, Wire rope : Bharat Wire Rope, Orion Ropes, Usha Martin Bearings for Cranes : SKF, FAG Bearings for other equipment : SKF, FAG, Tata Timken, Asian Bearings, NRB,MBM Oil Seals : Vaco Oil Seals, Rubber Equipment & Engg. Sealjet India (Pune), Sealpack, Champion Seals Lubrication Fittings : Lubcon, AFMC, Prakash, Lincoln Lubricating Systems : AFMC, Prakash, Grindwell Norton, Lincoln Helios Gear box : New Allenburry, Greaves Cotton, ELECON, Shanti Gears, Flender, AR Engg, Kirloskar,I.C. Hydraulic Systems : Vickers Sperry, Yuken, Manesmann, Rexroth, Hugglands Denison-Parker Hydraulic Coupling : Fluidomat, Ghatge Patil, VOITH, Prembrill Centrifugal blowers Burners : : Recuperators : REITZ, Flaht Wood, James Howden (UK) Stein Heurtey, Techint, LOI, Weswan North American, Ecllpse, Hotwork Eastern Equipment, GEFFI (Germany) SAFMAT (France), North American Minnt. Co. Thermal Transfer Corporation (USA) © 2007 MECON Limited All rights reserved Preferred Makes Page 12 of 37 GS-13 General Technical Specification Item Description Manufacturers Hydraulic Power/Cylinders : Rexroth, Vickers, Wipro, Veljan, Yuken, Oscar. High Pressure Vane/Piston Pump : Vickers, Yuker, Rexroth, Hugglands, Denison Crusher : Sayaji, HEC, McNally Bharat, TRF, ELECON DCEM Brake : Track type Limit Switch : Electromag, BCH, Industries Syndicate, Storm Kraft, Speed-O-Control Electromag, BCH, Speed-O-Control, Jayshree, EP&C, Bengal Technocrats Thruster Brake : Electromag, BCH, Speed-o-Control, Elite Belt changing Device : Nilos, Shawalmex Conveyor Belting : Northland Rubber Vibrating Screen : IC, TRF, ELECON, McNally Bharat, L &T, HEC, Orien, Electromag, Hydrabad Industries Vibratory Feeder : Electromag, IC, TRF, ELECON, McNally Bharat Magnetic Separators : Electromag, WMI, Magnet Corporation, Electro magnetic Ind., Ericz, Sartorius, Hans Bockels, Krupp Forder, Technick ,L & T Pneumatic Actuators : Prepec, Technomech, Nucon OSCAR Equipt, Veljan Hydair. Electro Mechanical Actuators : PREPEC, Technomech, Pebco © 2007 MECON Limited All rights reserved Rubber, Preferred Makes Page 13 of 37 Usha Telehoist, Phoenix-Yule, Orien Oriental Engineers, Industries, GS-13 General Technical Specification Item Description Manufacturers Rubber liner : TEGA, Kaveri Polymer liner : TEGA, Kaveri Polyethelene liner : Kaveri, Tega Polyurethane liner : Kaveri, Tega Cast Basalt liner : DECCAN, Enviro Abrasion Belt Scraper/ Belt Cleaner : Belt Switches Bin Vibrator : : Hosch Equipment, Vinar IDC, Kaveri Macmet, Hindustan Udyog Ltd., Karam Chand Thapper, Cobit Engg, Elecon, TRF, Promac, BMH Concare Jayshree, PROTO CONTROL, EPC Electromag, Electromagnetic Industries, IC Samplers : Prisector (UK), Ramsay Engg (USA), Eastmn Crusher, Advanced system sampling (P) Ltd. Belt Vulcanisers : Shaw Almex, Nilos India, SV Dattar Sector Gates, Diverter Gates, Rack and Pinion Gates etc. : Vinar, IDC, Macmet, TRF, Precision Processing, Moktali, Holtzman, Mining & Material, Chennai Radha, Flexowel Conveyors : METSO, Flexowel Drag Chain Conveyors : Moktali Engrs., TRF, Equipt Engrs, Redler India, Enviro Abrasion, Karam Chand Thapar, © 2007 MECON Limited All rights reserved Preferred Makes Page 14 of 37 GS-13 General Technical Specification Item Description Manufacturers Bucket Elevator : Moktali, Golden Electrical, Hindustan Udyog, Vinar, Cobit, Shree Conveyor, IDC, Orien, Macmet, Elecon, TRF Belt Feeder : Reclaimer : Vinar, IDC, HEC, Orien, Macmet, Elecon, TRF, Cobit Metso, L&T, Elecon, TRF, HEC Stacker : Metso, L&T, Elecon, TRF, HEC Stacker – CumReclaimer Wagon Tippler : Metso, L&T, Elecon, TRF, HEC : L&T, HEC, Elecon, TRF, Metso Wagon Loader : L&T, HEC, Elecon, TRF, Metso Belt Weigh Feeders & Weigh Hopper : Kistler – Morse, Sartorius Mechatronics, Transweigh, Avery, Jenson Nicholson Belt Weigh Scale : Kistler-Morse, Transweigh, Avery, Sartorius Mechatronics, Jenson Nicholson Conveyor belt pulleys : Elecon, TRF, McNally Bharat, Macmet, HEC Conveyor Idlers : Elecon, TRF, McNally Bharat, Kali, Hindustan Udyog Ltd., Macmet Pneumatic Handling Equipment : TTG, Scorpio Front – end – loader : TIL, Hyderabad Industries Ltd., Fork-lift-truck : Godrej, Voltas, TIL © 2007 MECON Limited All rights reserved Preferred Makes Page 15 of 37 GS-13 General Technical Specification 05. REPAIR & MAINTENANCE FACILITIES Item Description Manufacturers Centre Lathe : HMT, Mysore Kirloskar, HEC Universal Milling m/c : HMT, BFW, Batliboi Shaper : PAL, P&B, Loyal Radial Drilling m/c : HMT, Batliboi, Kerry Jost, HEC Horizontal Boring m/c : HMT, HEC, PAL Submerged Arc Welding Set : Advani, ESAB, ADOR, Mogora, COSMIC Welding Rectifier : Advani, ESAB, ADOR, Mogora, COSMIC Welding Transformer : Advani, ESAB, MEMCO Universal Tool and Cutter Grinding m/c : HMT, Praga, Batliboi Hydraulic Press : BEMCO, P&B, Centerprise Cast Iron Plate : Jash, Madras Gauge, P&B Power Hacksaw : ITL, P&B, EIFCO Column Drilling m/c : HMT, Thakoor, Kerry Jost, EIFCO, Batliboi Bench Drilling m/c : Accuax, EIFCO, P&B, Thakoor Double-ended Pedestal Grinder : Grind Tools, GECO, AMC, P&B Cylindrical Grinder : HMT, Mysore Kirloskar, ELP Tools & Tackles : P&B, Mekaster, Centerprise, Ally Measuring Tools and Gauges : P&B, Bombay Tools Garage Equipment : ELGI, USHA, WAP, P&B Oiling & Greasing : ELGI, P&B © 2007 MECON Limited All rights reserved Preferred Makes Page 16 of 37 GS-13 General Technical Specification 06. ELECTRICAL The list of acceptable makes for various electrical and automation equipment is given below. A ) POWER DISTRIBUTION EQUIPMENT SL. NO. EQUIPMENT PREFERRED MAKES TRANSFORMERS 1. a) DISTRIBUTION TRANSFORMER (OIL TYPE) (11 or 6.6/0.433 KV) ABB / AREVA / / CGL / BHEL / BHARAT BIJLEE / VOLT AMP/ KIRLOSKAR /INTRA VIDYUT / b) DRY TYPE TRANSFORMER INTRA VIDYUT / VOLTAMP / KEC 2. 11kV / 6.6KV ISOLATOR A BOND STRAND / S&S,MADRAS / HIVELM / SIEMENS / DREISCHER-PANICKER. 3. 415V SWITCHBOARD SIEMENS / L&T / GE POWER / SCHNEIDER 4. LT BUSDUCT STARDRIVE / C&S / PCE / ECC / BRIGHT ENGINEERS/ VIDHYUT CONTROL 5. BATTERY a) NICKEL - CADMIUM AMCO / HBL NIFE b) VALVE REGULATED LEAD ACID MAINTENANCE FREE BATTERY (VRLA) HBL NIFE / AMARARAJA / EXIDE c) BATTERY ( PLANTE) HBL NIFE / AMARARAJA / EXIDE 6. BATTERY CHARGER/ DCDB CHHABI / HBL NIFE/ CALDYNE / AMARA RAJA / KIRLOSKAR 7. PROTECTIVE RELAYS AREVA / ABB / SIEMENS/ER 8. AUXILIARY RELAYS ABB / ER / SIEMENS / AREVA 9. HEAT SRINKABLE CABLE JOINTING KITS/ STRAIGHT THROUGH JOINTS (H.T) RAYCHEM / DENSON / M-SEAL 10. METER (ANALOGUE TYPE) IMP / AE / MECO / SECURE METERS / CONZERV / L&T / RISHAV 11. CURRENT TRANSFORMERS ABB / SILKANS / INSTRANS / PRAGATI / IMP/ AE / KAPPA / PRAYOG / SIEMENS / L&T 12. POTENTIAL TRANSFORMER ABB / BHEL / SILKANS / PRAGATI / IMP / KAPPA / PRAYOG /SIEMENS / ABB / INDOCOIL / PRECISION © 2007 MECON Limited All rights reserved Preferred Makes Page 17 of 37 GS-13 General Technical Specification SL. NO. EQUIPMENT PREFERRED MAKES 13. 11KV/ 6.6KV CABLES ASIAN CABLES (RPG) / CCI / UNIVERSAL / NICCO / POLYCAB / HAVELLS 14. DIGITAL TYPE MULTIFUNCTION METER CONSERVE / L&T / SECURE / ER / RISHAV B ) LT PANELS , DRIVES , AUTOMATION & CONTROL ACCESSORIES. SL.NO. 1. SUB GROUP MAKES MCC (NON DRAW OUT) POWER DISTRIBUTION BOARD (PDB) CONTROL DESK &POST HINDUSTAN CONTROL / POWER & PROTECTION / ECC / VENUS / BCH / HAVELLS / GEMCO 4. LOCAL CONTROL STATION (LCS) HINDUSTAN CONTROL / POWER & PROTECTION / ECC / VENUS / BCH / HAVELLS / GEMCO 5. LIGHTING DISTRIBUTION BOARD MLDB, SLDB HINDUSTAN CONTROL / POWER & PROTECTION / ECC / VENUS / GEPC / BCH 6. VVVF AC DRIVE ABB / ROCKWELL AUTOMATION / SIEMENS / VACON / SCHNEIDER / L&T 7. SOFT STARTER ROCKWELL AUTOMATION / ABB / SCHNEIDER / SIEMENS 8. PROGRAMMABLE LOGIC CONTROLER (PLC) ABB ( 800 XA) / GE-FANUC ( PAC Rx7i) / ROCKWELL AUTOMATION (CONTROLOGIX) / SIEMENS (S7 SERIES) 9. UNINTERRUPTED POWER SUPPLY (UPS) LT AC MOTOR (SQ. CAGE) TATA LIBERT (EMERSON) / GE / FUJI / DB ELECTRONICS ALSTOM / KEC / CGL / SIEMENS 12. LT AC MOTORS (CRANE DUTY) HT AC MOTOR 13. LT AC GEARED KIRLOSKAR ELECTRIC / POWERBUILD / NEW ALLEN 2. 3. 10. 11. © 2007 MECON Limited All rights reserved SCHNEIDER / L&T / SIEMENS / GEPOWER HINDUSTAN CONTROL / VENUS / SIEMENS / ABB / L&T / GEPC / HAVELLS ABB / BHARAT BIJLEE / CGL / KIRLOSKAR ELECTRIC ALSTOM / SIEMENS BHEL / ABB / CGL / SIEMENS / KIRLOSKAR ELECTRIC / ALSTOM / WEG / GE Preferred Makes Page 18 of 37 GS-13 General Technical Specification SL.NO. 14. 15. 16. 17. 18. 19. 20. 21. 22. SUB GROUP MAKES MOTOR BERRY / IEC / AUMA FLAME PROOF LT SQUIRREL CAGE AC MOTOR SLIPRING MOTOR (OTHER THAN CRANE DUTY) LT AC VVVF MOTORS FOR ROLLER TABLE APPLICATION STALL TORQUE MOTOR ACTUATOR ALSTOM / BHARAT BIJLE / ABB / CGL KIRLOSKAR ELECTRIC / SIEMENS MOTOR PROTECTION CIRCUIT BREAKER (MPCB) MOULDED CASE CIRCUIT BREAKERS (MCCB) MINIATURE CIRCUIT BREAKER (MCB) CGL / ALSTOM / SIEMENS / KIRLOSKAR ELECT CO. SIEMENS / ABB / KIRLOSKAR ELECT CO. / ALSTOM / CGL DEMAG AUMA / ROTORK / LIMITORQUE SCHNEIDER / ABB / L&T / GEPOWER / SIEMENS SIEMENS / ABB / L&T / GEPOWER / SCHNEIDER HAVELLS / MDS LEGRAND / SCHNEIDER / STANDARD / GEPOWER / HAGAR (L & T) / ABB / SIEMENS EARTH LEAKAE CIRCUIT BREAKER.(ELCB) HRC FUSES HAVELLS / MDS LEGRAND / SCHNEIDER / STANDARD / GEPOWER / HAGAR (L & T) / ABB / SIEMENS VACUUM CONTACTOR (LT) AC POWER CONTACTORS SIEMENS / L&T / ABB / SCHNIEDER 26. CRANE DUTY POWER CONTACTORS ABB / SCHNEIDER / L&T / SIEMENS / GEPOWER 27. THERMAL OVER LOAD RELAY ABB / C&S / BCH / L&T / SCHNEIDER/ GEPOWER / SIEMENS 28. ELECTRONIC THERMAL OVERLOAD RELAY CONTROL SWITCHES / SELECTOR SWITCHES FANOX / SAMWHA / MOELLER / LG / SPECHER & SCHUH 23. 24. 25. 29. © 2007 MECON Limited All rights reserved L&T / SIEMENS / BUSMAN / GEPOWER / INDO-ASIAN ABB / L&T / SCHNEIDER / SIEMENS / GE POWER / BCH ABB / ALSTOM / BCH / KAYCEE / GEPOWER / SIEMENS Preferred Makes Page 19 of 37 GS-13 General Technical Specification SL.NO. SUB GROUP MAKES 30. PUSH BUTTONS BCH / L&T / SCHNEIDER / SIEMENS / GEPOWER 31. TIMERS/TIME DELAY RELAY AUXILIARY RELAYS ABB / BCH / L&T / GEPOWER / SIEMENS / EAPL ABB / BCH / L&T / SCHNEIDER / GEPOWER / SIEMENS 33. MASTER CONTROLLER EPCC (KAKKU) / SCHNIEDER / SIEMENS / STROMKRAFT / TELEMECHANIQUE 34. LIMIT SWITCHES BCH / EPCC (KAKKU) / AG MECHANIC / ESSEN GEPOWER / JAIBALAJI / SCHNEIDER / SIEMENS 35. PULL CORD SWITCHES EPCC (KAKKU) / AG MECHANIC / TELEMECHANIQUE / JAYSHREE ENTERPRISES / STROMKRAFT / PROTO CONTROL 36. BELT SWAY SWITCH EPCC (KAKKU) / AG MECHANIC / TELEMECH / JAYSHREE ENTERPRISES / STROMKRAFT / PROTO CONTROL 37. GRAVITY TYPE LIMIT SWITCH ROTARY LIMIT SWITCH EPCC (KAKKU) / STROMKRAFT / KAYCEE EPCC (KAKKU) / AG MECHANIC ENTERPRISE / SCHNEIDER / TELEMECH 39. PROXIMITY &PHOTO ELECTRIC SENSORS ROCKWELL / SCHNIEDER / SIEMENS/ OMRON / SICK / DELTA / LINE & LINDE / TELEMECHANIQUE 40. PULSE ENCODER HUBNER / HEIDENHEIN / ROCKWELL AUTOMATION (ALLEN BRADLEY) / LEONARD BAUR GERMANY / SICK (GERMANY) 41. INDICATING LAMP LED TYPE SIEMENS / L&T / BINAY / ESSEN / BCH / VAISHNO 42. HOOTER / BUZZER / BELL / SIRENS SOLID STATE ANNUNCIATOR EPCC (KAKKU) / KHERAJ 32. 38. 43. ADVANI OERLIKON / AREVA / APLAB/ CONTROL & DYNAMICS / DIGICON INSTRUMENTATION LTD. / L&T / MINILEC 44. TEMP. SCANNER ADVANI OERLIKON / ECIL / INSTRUMENTATION LTD. / MASIBUS / PYROTECH / SIEMENS 45. LAMPS BAJAJ / CROMPTON GREAVES / GE LIGHTING / PHILIPS / OSRAM / SIGMA 46. LIGHT FITTING (FIXTURES) BAJAJ / CROMPTON GREAVES / GE LIGHTING / PHILIPS © 2007 MECON Limited All rights reserved Preferred Makes Page 20 of 37 GS-13 General Technical Specification SL.NO. SUB GROUP MAKES 47. COMPLETE WITH ALL ACCESSORIES EXCEPT LAMP. LIGHTING WIRE (PVC) 48. 5A/15A PIANO SWITCH ANCHOR / ELLORA / MDS LEGRAND / PRECISION / HAVELLS 49. 50. FLAME PROOF LIGHT FITTING EXHAUST FANS GOVAN / BALIGA / FLEXPRO / SUDHIR / CEAG / FCG / SIGMA CGL / KHAITAN / BAJAJ 51. CEILLING FANS CGL / KHAITAN / HAVELS 52. PERSONAL COMPUTER LAP TOP/ NOTEBOOK HP / DELL. / LENOVO / IBM 53. 54. CCI / DELTON / FINOLEX / NICCO / UNIVERSAL IBM / HP / LENOVO / DELL HRC FUSE (SEMICONDUCTOR PROTECTION) ELECTRONIC WEIGHING SYSTEM ABB / SARTORIOUS / SANMAR / SCHENK / TRANSWEIGH / KELK 56. PVC POWER CABLES (LT) CCI / UNIVERSAL / NICCO / RPG CABLES (ASIAN) / POLYCAB / FINOLEX / TORRENT / HAVELLS 57. PVC CONTROL CABLES 58. HEAT RESISTANT CABLES (EPR/CSP & SR) SCREENED CABLES & SPECIAL CABLES CCI / LAPP / NICCO / RPG CABLES (ASIAN) / UNIVERSAL / POLY CAB / FINOLEX / TOSHNIWAL / DELTON CCI / LAPP / NICCO / RPG CABLES (ASIAN) / UNIVERSAL / TOSHNIWAL / DELTON 55. 59. 60. BUSMANN / JE MULLER / FERRAZ / GEPOWER / SIEMENS CCI / BELDEN / LAPP / FINOLEX / POLY CAB / NICCO / TOSHNIWAL / DELTON CABLE TERMINATION KITS (XLPE) TERMINAL CONNECTOR CONNECT WELL / ESSEN-DINKY / PHOENIX / WAGO / LAPP 62. TRAILING CABLES LAPP / CCI / UNIVERSAL / ASIAN / NICCO 63. WELDING SOCKET BCH / SCHNIDER / BEST & CROMPTON / GEPOWER / HAVELL / JAIBALAJI 64. LIFTING MAGNETS ELECTROMAG / EPCC (KAKKU) / STERLING MAGNETICS / SUPERLIFT 65. POWERPACK FOR MAGNETS ELECTROMAG / BCH / EPCC (KAKKU) 61. © 2007 MECON Limited All rights reserved MSEAL, 3M / RAYCHEM Preferred Makes Page 21 of 37 GS-13 General Technical Specification SL.NO. SUB GROUP MAKES 66. RESISTORS (CRANE) BCH / ELECTROMAG / AMP CONTROL / EPCC / SIEMENS / RESITECH / NARKHEDGE 67. LT CAPACITORS GEPOWER / ABB / CGL / UNI STAR / BHEL 68. CABLE REELING DRUM BENGAL TECHNOCRAT, / ELECTRO ZAVOD / ELECTROMAG 69. DC ELECTROMAGNETIC BRAKE ELECTRO MAGNETIC OVERLOAD RELAYS BCH 71. OIL DASH POT OVERLOAD RELAYS KILBURN ELECTRICALS LTD / ELECTROGEAR 72. CONTROL TRANSFORMERS SIEMENS LTD. / INDCOIL MANUFACTURING CO. / INTRAVIDYUT / AUTOMATIC ELECTRIC LTD. (AE) / INDUSHREE / BHARTIA CUTLER-HAMMER LTD. 73. CRANE CONTROL PANELS HINDUSTAN CONTROL / ECC / VENUS / MEDITRON / EPCC 70. BHARAT HEAVY ELECTRICALS LTD / BHARTIA CUTLER-HAMMER LTD / KILBURN ELECTRICALS LTD. C) FIRE DETECTION & ALARM. (F.D.A) SYSTEM SL.NO . 1. 2. 3. 4. 5. 6. 7. DEVICES MAKES INTELLIGENT DETECTORS ( PHOTO ELECTRIC, HEAT, THERMAL) UL /FM / APPROVED INTELLIGENT FIRE ALARM CONTEROL PANELS UL /FM / APPROVED ADDRESSABLE MANUAL CALL POINTS INCLUDING HAND SETS . UL /FM / APPROVED MONITOR MODULES UL /FM / APPROVED FAULT ISOLATION MODULE UL /FM / APPROVED CONTROL MODULES UL /FM / APPROVED UV FLAME DETECTORS UL /FM /APPROVED © 2007 MECON Limited All rights reserved SIMPLEX / NOTIFIER / EDWARDS -DO-DO-DO-DO-DOPATOL / DETRONICS / SPECTREX Preferred Makes Page 22 of 37 GS-13 General Technical Specification 8. 10. BEAM DETECTORS UL /FM / APPROVED IR FLAME DETECTORS SOLAR BLIND EMBER, FIRE UL /FM / APPROVED ANALOG LINEAR HEAT SENSING CABLE 11. A) WITH METAL BRAID STEEL/BRONZE, COPPER B) WITH NYLON BRAID UL /FM / APPROVED DIGITAL LINEAR HEAT SENSING CABLE KIDDE / L.G.M / PATOL A) WITH NYLON BRAID B) WITH METAL BRAID STEEL, BRONZE, COPPER . UL /FM / APPROVED CONTROL UNIT FOR DIGITAL LHS CABLE UL /FM / APPROVED VIDEO DISPLAY UNIT INCLUDING CPU, PC, MONITOR, PRINTER ETC. DELL / HP / HCL / WIPRO / IBM COMPATIBLE. 9. 12 13 14 SIREN CABLES A: FOR DETECTOR CABLING (I) IMPORTED (II) KIDDE / L.G.M / PATOL. BELDON / SOUTHWEST / ALPHA INDIGENOUS POWER CABLE 16 SIGNAL CABLE 17 M.S.CONDUIT AS PER IS-9537-PART-II1981 GI CONDUITS ROAD CROSSING G.I PIPES © 2007 MECON Limited All rights reserved ODTI / PATOL / DET-TRONIX / SPECTREX KHERAJ / BEMCO / TULU 15 18 19 EDWARDS / NOTIFIER / SIMPLEX FINOLEX / DELTON / UNIVERSAL / NICCO / POLYCAB / FORTGLOSTER / HAVELLS FINOLEX / DELTON / UNIVERSAL / NICCO / POLYCAB / FORTGLOSTER / HAVELLS USHA BELTON / HCL / DELTON / VINDHYA TELELINK NICCO / BHARAT / ZENITH / BEC / CENTURY BEC / NICCO / ZENITH NICCO / TATA / JINDAL Preferred Makes Page 23 of 37 GS-13 General Technical Specification 1. ELECTRONICS CORPORATION OF INDIA LTD, 2. TECHNICAL TRADE LINKS PVT. LTD. 3. GUNNEBO INDIA LTD., 4. MATHER & PLATT PUMPS (I) LTD. 5. M/S AGNICE FIRE PROTECTION LIMITED. 20 F.D.A SYSTEM SUPPLIERS 6. M/S TECHNICO (INDIA) PVT. LIMITED. 7. NOTIFIER. 8. SIEMENS. 9. TECHNO FIRE. 10. NEW FIRE. 11. TYCO FIRE & SECURITY. 21 ELECTRONIC PRIVATE AUTOMATIC BRANCH TELEPHONE EXCHANGE (EPABX) SUPPLIERS 1. M/S INDIAN TELEPHONE INDUSTRIES LIMITED. 2. M/S AVAYA GLOBAL CONNECT LIMITED. 3. M/S SIEMENS LIMITED. 4. M/S ALCATEL. 5. M/S B.P.L TELECOM PVT. LIMITED. 6. M/S CROMPTION GREAVES LIMITED. 7. ERICSSON. 1. M/S E.C.I.L. 2. M/S NELCO LIMITED. 22 C.C.T.V SYSTEM SUPPLIERS 3. M/S DATAMATICS INFORMATION TECHNOLOGY LIMITED. 4. M/S PHILIPS/BOSCH 5. M/S PELCO © 2007 MECON Limited All rights reserved Preferred Makes Page 24 of 37 GS-13 General Technical Specification 23 LOUD SPEAKER TALK BACK(LSTB) / LOUD SPEAKER INTERCOMMUNICATION(LSIS) SYSTEMS SUPPLIERS 1. M/S POWER SYSTEMS. 2. PHI-AUDIOCOM. 3.M/S MOTAWANE PRIVATE LIMITED 1. DELTON CABLES. 24 TELEPHONE CABLE SUPPLIERS 2. TELE-LINK NICCO. 3. FINOLEX. 25 26 07. FIBRE OPTIC (F.O) CABLE. MOLEX/LUCENT/AMPHINOL/BIRLA ERRICSSON/OPTEL. V.H.F SYSTEM MOTORALA/ YEASU/SIMOCO/ADINO INSTRUMENTATION Sl. No. ITEM DESCRIPTION PREFERRED MAKES A. Field Instruments: 1. Pressure / Differential Pressure gauge : 2. Pressure switches. : 3. Pressure / Differential Pressure Transmitters : Emerson (Rosemount), Chemtrols (Fuji), Honeywell, Yokogawa, Siemens , ABB 4. Temperature gauges : WIKA, Manometer India, A.N. Instruments, General instruments, Waaree instruments, GE gauges, Walchandnagar, Precision Industries. 5. Thermocouple & RTD / thermowell : General Instruments, Nagman Instruments, Toshniwal / © 2007 MECON Limited All rights reserved Differential Pressure WIKA, Manometer India, A.N. Instruments, Precision Industries, General Instruments, Waaree instruments, Forbes Marshall, Walchandnagar (Tiwac) , Hirlekar (DP gauge) Ifm. WIKA, Kasturba (Orion-Ashcroft),Switzer, Indfoss, Vasutech, Preferred Makes Page 25 of 37 GS-13 General Technical Specification Sl. No. ITEM DESCRIPTION PREFERRED MAKES Industries, Tempsens, Pyro-electric Instruments, Industrial Instrumentation, Altop, Waree, Detriv. 6. Temperature Switch : WIKA, Manometer India, A.N.Instruments, Instruments, Indfoss, Switzer, Vasutech. 7. Temperature transmitter : Emerson (Rosemount), Yokogawa, Honeywell, Siemens, Fuji (Chemtrols,) , ABB 8. Rotameters : Krohne-Marshall, Instrumentation engineers, Eureka instruments. Chemtrols, Rota Instruments. 9. Orifice Plate & flanges Assembly/ Venturi , Flow nozzle : Engineering Specialities, Micro-precision, Hydropneumatics, Chemtrols-Samil, Instrumentation ltd, 10. DP type Flow / Level Transmitters : Emerson (Rosemount), Chemtrols (Fuji), Honeywell, Yokogawa, Siemens , ABB 11. Flow Switch : Ifm. , Krohne-Marshall, Switzer, Levcon, D.K. Instruments, 12. Electromagnetic flow meter : Yokogawa, Emerson (Rosemount), Krohne-Marshall, Endress & Hauser, ABB. 13. Vortex Flow meter : Emerson(Rosemount), Krohne -Marshall, Yokogawa, Vortex Instruments 14. Mass (coriolis) flow meter Emerson (Rosemount) , Yokogawa, Krohne –Marshall, ABB, Endress & Hauser, Rockwin. 15. Level gauge (magnetic & reflex type) Chemtrol, Levcon Instruments, Pratolina Instruments, Waaree Instruments, Forbes Marshall, Techtrol, Sigma, Asian Industrial Valves & Instruments. 16. Level Switch (Conductivity type) : Chemtrol (Vega), Endress & Hauser, Switzer Instruments, SB Electro-mechanical, Techtrol, Nivo Controls, LevelTech 17. Level Switch (Capacitance/RF type) : Chemtrol (Vega), Endress & Hauser, Switzer Instruments, SB Electro-mechanical, Techtrol, Nivo Controls, LevelTech 18. Level Switch (Tuning fork/ Rod type) : Chemtrol (Vega), Endress & Hauser, S.B. Electromechanical, ,Nivo Controls 19. Level Switch (Float type) : Emerson,Trac, Chemtrols, Forbes Marshall, D K Instruments, Levcon Instruments, Techtrol , V-Automat, Warree © 2007 MECON Limited All rights reserved Preferred Makes Page 26 of 37 GS-13 General Trac, General Technical Specification Sl. No. ITEM DESCRIPTION PREFERRED MAKES 20. Level Switch/ Transmitter (Displacer type) : Emerson, Chemtrols (Eckard), Trac, D K Instruments, Levcon Instruments, 21. Level Switch/ Transmitter (Ultrasonic type) : Chemtrol (Vega) , Endress & Hauser, Krohne Marshall, Siemens (Miltronics) ,Toshbro controls (Enraf) 22. Level Switch/ Transmitter (Radar type) : Chemtrol (Vega) , Emerson (Rosemount), , Endress & Hauser ,Toshbro controls (Enraf), Krohne- Marshall 23. Level Switch/ Transmitter (Nucleonic type) : Concord International (Dr. Berthold), Emerson (Kay Ray), ECIL. 24. Level switch (Electro- mech type) : Nivo Controls, mechanicals. 25. Control valve : Fisher-Xomox ,Instrumentation Ltd, Dresser Industries (Masoneilan) , Valtek, Samson Controls(Globe type), Forbes Marshall ( Arca ), ABB, Fouress, Tyco valves (Keystone- Butterfly), MIL Controls, Dembla 26. Electrical Actuator : Auma, Limitorque, Marsh, Instrumentation Ltd Endress & Hauser, S.B. Electro- ( Bernard), Rotork, Keystone. 27. Pneumatic Actuator : Fisher-Xomox , Instrumentation Ltd., Dresser Industries (Masoneilan), Valtek, Samson Controls, ABB, MIL Controls, Forbes Marshall (Arca), Keystone, Virgo, Habonim Vaas.. 28. Electro-hydraulic actuator : Reineke, Askania 29. Self- regulating pressure control valve : Samson Controls, Nirmal Industries, Forbes Marshall, Instrumentation Ltd. 30. I/P converters : Shreyas-Barton, Fisher –Xomox, Forbes Marshall (Moore products), Marsh-Bellofram, MIL controls, ABB, Watson – Smith. 31. Pneumatic Positioner, : Instrumentation Ltd., Fisher-Xomox , Dresser Industries (Masoneilan), Samson Controls, Forbes Marshall ( Arca), ABB, Fouress, MIL, 32. Electro- pneumatic positioner 33. Solenoid Valve © 2007 MECON Limited All rights reserved Fisher-Xomox, ,Siemens, Dresser Industries (Masoneilan), Samson Controls, Instrumentation Ltd., Forbes Marshall (Arca), ABB, Fouress, MIL controls. : Burkert, Herion, Rotex, Schrader-Schovill, Jucomatic, Avcon, .Asco Preferred Makes Page 27 of 37 GS-13 General Technical Specification Sl. No. 34. B. ITEM DESCRIPTION Air filter regulator PREFERRED MAKES : Shavo-Norgren, Schovill. Marsh-Bellofram, Placka, Schrader- Control room Instrumentation 1. Distributed Control System (DCS) : Yokogawa (CS 3000), Honeywell (Experion +C 300), ABB (AC 800 XA), Emerson (Delta V), Siemens (PCS 7+ S7400H). 2. Programmable Logic Controllers. : Refer Electrical list. 3. Digital Indicator : Pyrotech Electronics, Lectrotek, Chino-Laxsons, Micro systems, Master Electronics, Masibus Instruments, Ranutrol, Honeywell. 4. Bargraph Indicator : Chino-Laxsons , Masibus Instruments , Pyrotech Electronics, Lectrotek, Teletherm. Ranutrol 5. Recorders (Chart Less) : Eurotherm, Yokogawa, Siemens, ABB. 6. Microprocessor based controller : Yokogawa, Siemens, Honeywell, Eurotherm, Fuji, ABB, Forbes Marshall,Toshiba 7. Digital scanners : Lectrotek, Micro systems, Master Electronics, MB controls, Masibus Instruments, Procon. 8. DC Power Supply Unit : Aplab, Elnova,Siemens, Phoenix, Schneider, 9. IS Interface/Zenner Barrier 10. Signal isolators : Pepperl & Fuchs, MTL, Stahl, Yokogawa, Forbes Marshall (Protech), Chino-Laxsons, Phoenix 11. Annunciation system : IIC, Procon, Micro Systems & Controls, Minilec, Instrumentation Ltd, Lectrotek, Piri systems, Pyrotech Electronics, MB controls & Systems Semuda. 12. Instrument Panels/ Control Desk : Rittal, Pyrotech, Radha Krishna Controls, Instrumentation Ltd. 13. Instrumentation Cable © 2007 MECON Limited All rights reserved Chino-laxsons, Honeywell, Pepperl & Fuchs, MTL, Stahl Universal Cables, Delton, Thermopads, KEI industries, Paramount Cables, Lapp cables, Cords cables, Uniflex cables, Brooks Cables, Elkay Telelinks, Rajnigandha, Special Cables, TCL Cables, Friends Cable, Daksha Cable, Crystal Cables, Udey Pyro-Cables, Elkay Telelinks, Fort Gloster Preferred Makes Page 28 of 37 GS-13 General Technical Specification Sl. No. ITEM DESCRIPTION PREFERRED MAKES 14. Thermocouple Compensating Cable C. Analytical / Special Instruments 1. Gas analysis Instruments 2. Gas Detectors 3. Calorific Value (CV) analyzers : Reineke, Union. Yokogawa 4. Moisture Analyzers (Nucleonic) : Concord International (Dr. Berthold), Emerson (Analytical) 5. ORP/PH/ Conductivity meter / Transmitter : Emerson (Analytical), Forbes Marshall (Polymetron), Yokogawa, ABB, Ion Exchange, Honeywell. 6. Moisture Sensor & Transmitter : Invensys (Foxboro), Bartec, GE-Panametrics 7. Flame Detector : Honeywell, Durag Instruments 8. Vibration sensors & monitors : Bentley Nevada, Schenck -Avery, Josts Engineering (Bruel & Kjaer), SPM Instruments, , Mechanalysis India (IRD). 9. Positive Displacement meter : Toshbro controls.(Bopp & Reuther), Forbes Marshall ( Moorco products), Liquid Controls, Emerson. 10. Annubar / Flow tube : Emerson, Switzer Instruments. 11. Infrared radiation pyrometer : Land, Chino-Laxsons, Toshniwal (Raytek), Ircon, Nagman (Wahl), 12. Dip lance type Molten metal temperature measurement system T/C Tips : Ardee Enterprise ( Electronite) , Ferrotran 13. Slag detection system : Elof Hanson (EMLI), Land. © 2007 MECON Limited All rights reserved : Toshniwal Cables, General Instruments, Paramount Cables, Udey pyro-cables, Cords cables, Brooks, Daksha Cables, Friends Cable. : ABB (H&B), MSA, Emerson, Siemens, Chemtrols (Maihak), Forbes Marshall, Fuji, Beiler & lang (COMonitor), Honeywell, Yokogawa. Beiler & lang (CO-Monitor), Dragger, Oldham, Industrial Scientific Corporation, Detronics. & Preferred Makes Page 29 of 37 GS-13 General Technical Specification Sl. No. ITEM DESCRIPTION 14. SPM analyser 15. SOx- NOx analyser 08. PREFERRED MAKES Emerson, Yokogawa, Durag, ABB, Honeywell, Forbes Marshall (Codel). Forbes Marshall, Emerson, Yokogawa, ABB, Honeywell FIRE PROTECTION SYSTEM 1. Steel pipes - SAIL, ITC, JINDAL, Ajanta, Maharastra Seamless, Prakash Tubes Gujarat Steel tubes, 2. Steel pipes fittings - Tube Bends, Jindal, Ajanta Shivananda, EBY Industries. 3. Spray nozzles/Projectors - 4. Deluge valves - Mather & Platt, ACE turnkey, Vijay Fire Protection System Ltd, HD Fire. 5. Outside coating& Wrapping for pipes - Llyods/STP 6. Quartzoid bulb detector - H.D. Fire Protect Co., Mather & Platt, Any other TAC approved make 7. Diesel Engine : Kirloskar-Cummins, CromptonGreaves, Ashok Leyland 8. Fire extinguishers : New Fire, VIPL, Zenith, ASCO Strumech 9. Fixed fire protection system - New Age, Agnice, Vijay Industries& Project , Lloyds © 2007 MECON Limited All rights reserved Laxmi sprinklers, Reliable, Avon, Mather and Platt, HD Fire. Preferred Makes Page 30 of 37 GS-13 General Technical Specification 10. 09. Passive Fire protection Insulation, Techno Fire Controls New Fire Engineers Llyod, 3M, Vijay System, Signum BOF GCP EQUIPMENTS:Following equipment/supplies specific to BOF-Gas Cleaning Plant shall be manufactured by any of the following vendors listed below:- © 2007 MECON Limited All rights reserved Preferred Makes Page 31 of 37 GS-13 General Technical Specification SL. NO. EQUIPMENT VENDOR/MANUFACTURER 1. Hood, Stack and Lance sealing device ISGEC, ACC-BABCOCK (ABL), BHPVL, L & T 2. Hood traverse carriage, Stack inspection device, Hood bottom closure device L&T, WMI CRANES, JESSOP, MUKAND 3. Pressure vessels ISGEC, ABL, BHPVL, TSL, KAVERI ENGG. - Expansion vessel, Mixing drum, Make-up water tank, Sample cooler, Blow-down & drainage expansion tanks and Emergency spray vessel 4. Additive feeding system BEEKAY, SIMPLEX, MUKAND 5. Gas holder MICCO, SMS-DEMAG, CLAYTON – WALKER 6. Fabricated gas ducts (Dia> 1200 mm), Trestles/Duct Supports, Flare stack structure Walkways/Accesses BEEKAY, ROURKELA FABRICATION, BHARAT WEST – FALIA, SUBURBAN ENGG., KM UDYOG, OTTO, APV 7. Electrostatic precipitator (wet type) VOLTAS, OTTO, ORIENT, ANDREW YULE 8. ID fan NEU (France), JAMES HOWDEN (UK), ROTHEMUHLE (Germany), DONKIN (UK), FLAKTWOODS 9. Centrifugal horizontal CW pumps INGERSOLL, SULZER Fabricated equipments NHEC, BHPVL, KCP, BINNY ENGG. WORKS, ABL, ISGEC, OTTO - Stack cover plate, Saturator, Hydraulic seal Recycling tank, Convergent/Divergent ducts, Changeover device, Hydraulic nonreturn valve, Condensate seal pots, Sump cover © 2007 MECON Limited All rights reserved Preferred Makes Page 32 of 37 GS-13 General Technical Specification - For any other equipment/supplies which are not covered above, the make/manufacturer’s name shall be mutually agreed between Purchaser /Consultant and the successful Tenderer. 10. INFORMATION SYSTEM Preferred Makes for Level-II automation Server Computers : IBM/HP/SUN Client Computers (PC) : IBM/Lenovo/HP-Compaq/DELL Network Equipment • Active components • Passive components : : CISCO LUCENT/AMP Application software including Process control models : Technology Supplier © 2007 MECON Limited All rights reserved Preferred Makes Page 33 of 37 GS-13 General Technical Specification 11. FLUID SYSTEMS & PIPING ENGG (LUBRICATION & HYDRAULICS) PREFERRED MAKE OF ITEMS SL. NO. ITEM 1 Piston / Vane Pumps & Hydraulic Motors 2 Gear Pump 3 Screw Pump 4 5 6 7 Centrifugal Pump for Descaling System Piston Pump for Descaling System Centrifugal Pump (12 Bar & below) Submersible Type Sump Pump 8 Grease Lubrication System 9 Oil Lubrication System 10 Air Oil System 11 Air Controls 12 Hydraulic Proportional Valve 13 14 15 16 16.3 Hydraulic System Hydraulic Control Valve Hydraulic Servo Valve Manual Valves Manual Gate / Globe Valves with & without gear for High Pressure application Manual Gate / Globe Valves with & without for Low Pressure application (16 Bar and Low) Butterfly Valve 16.4 Ball Valve 16.5 Check Valve (Disc Type) – 16.1 16.2 © 2007 MECON Limited All rights reserved MAKE Rexroth / Parker / Kawasaki / Eaton Del Pd Pumps (ROTODEL) / Tushaco / Rexroth / Parker / Alfa IMO / Allwiler / Nortek AREA Hydraulics Hydraulics / Oil Lubrication Hydraulics / Oil Lubrication KSB / Halberg / Wier Descaling Uraca / Wepuko / Hauhinco Descaling KSB / Kirloskar / Voltas / Mather & Platt / Beacon / Wier Water KSB / Flygt / Grundfos Sump Lincoln Helios / Bijur Delimon / Nortek Lincoln Helios / Shaan Lube Rebs / Dropsa / Bijur Delimon / Nortek Rotex, / Schrader Duncan / Shavo Norgren / Nucon / Ross / SMC / Rexroth / Parker Rexroth / Parker / Eaton / Yuken (Japan) Rexroth / Parker / Eaton / Yuken Rexroth / Parker / Eaton / Yuken Moog / Rexroth KSB / BHEL / AUDCO / BDK Grease Oil Lubrication Air-Oil Lubrication Pneumatics Hydraulics Oil Lubrication / Descaling KSB / BHEL / VIRGO / AUDCO / BDK / Fouress / Akay AUDCO / VIRGO / BDK AUDCO / FOURESS / BDK / VIRGO / AUDCO / BDK / FOURESS Preferred Makes Page 34 of 37 GS-13 General Technical Specification SL. NO. 16.6 16.7 16.8 17 ITEM Low Pressure Check Valve ( Spring Loaded) – Low Pressure Check Valve (Spring Loaded) – High Pressure Check Valve (Disc Type) – High Pressure Control Valve for oil lubrication system 19 Spray Valve for Descaling System Air Release Valve 20 Air / Gas Safety Relief Valve 18 MAKE AUDCO / BDK / FOURESS AUDCO / BDK AUDCO / BDK Forbes Marshall / Samsung / Fisher / RK Controls / Nirmal Industrial Controls Oil Lubrication Hunt / Elwood Descaling Upadhyay / Steam & Mining / BDK Moorco / L & T / Fainger / Mankenberg Water L& T / Virgo / Rotex / AVCON Oil Lubrication Christie / Hydac / Parker / EPE Hydraulics Christie / Hydac / Parker / EPE Hydraulics WSR / BHPV / ISGEC Descaling Hydraulics Hydraulics 25 26 Actuators for operating Valves Accumulator with safety shut off block Accumulator Charging Kit Accumulator for Descaling System Pressure Filter Return Filter 27 Basket Filter 28 Auto Back wash Filter 29 Basket Strainer for water 30 HP Compressor Hydac / Pall / Internormen / Parker Hydac / Pall / Internormen / Parker Internormen / Hydac / Pall / Ball Filters Ball & Kirch, / Hydac / Fluid engineering Superflo / Hydac / EPE / Internormen / Multitex Ingersoll Rand / Aerotechnic Coltri 31 Heat Exchanger Alfa Laval / Indswep / Tranter 32 Level Indicator Switch Sigma / Levcon / Shridhan / Magnetrol / Buhler / Tectral / WEKA / Peneberthy / Kobold 33 Pressure Gauge & Temperature Gauge A.N. Instruments / H.Guru / Wika / Forbes Marshal / Stauff / Hydac / kobold 34 Pressure Switch Rexroth / Switzer / Hydac / Parker / Dadfoss (Indfoss) / Kobold 35 Differential Pressure Fisher Rosemount / Forbes 21 22 23 24 © 2007 MECON Limited All rights reserved AREA Preferred Makes Page 35 of 37 Descaling Oil Lubrication Descaling / Water Hydraulics / Oil Lubrication Descaling Hydraulics / Oil Lubrication Hydraulics / Oil Lubrication / Descaling Hydraulics / Oil Lubrication / Descaling / Utility Services Hydraulics / Oil Lubrication / Descaling Descaling GS-13 General Technical Specification SL. NO. ITEM Transmitter 36 Thermostat 37 Differential Pressure Gauge cum Switch 38 Pressure Transmitter 39 Temperature Transmitter 39 Flow Switch 40 41 Flowmeter cum Totaliser Pipes / Tubes 41.1 Carbon Steel Seamless Pipes / Tubes 41.2 Stainless Steel Seamless Pipes / Tubes 41.3 Carbon Steel ERW - SAW Pipes / Tubes MAKE Marshall Hydraulics / Oil Lubrication / Descaling Hydraulics / Oil Switzer / Danfoss / Indfoss / Hydac Lubrication / Descaling Hydac / Forbes Marshall Hydraulics Hydac / Forbes Marshall / Kobold / Johnson Control / Switzer / Hydac / Stauff / Verma Trafag / Johnson Control / Kobold Forbes Marshall / Stauff / Kobold / Rockwin / SMC / HYLOC / Flow Mon Rockwin / Forbes Marshall Jindal / Ratnamani / Maharashtra Seamless / MJ Patel / Indian Seamless / Gandhi Special Tubes / BHEL Jindal / Choksi Tubes / Ratnamani / MJ Patel Maharashtra Seamless / MJ Patel / Gandhi Special Tubes / SAIL / Jindal Saw / Ratnamani / Surya Roshni / MAN / Wellspun Hyd-air / Hyloc Hydoitechnic / MS Fittings / NL Hazra / Project Tooling Systems / Tube Bend / Parker / AVIT / Zest Technologies 42 Pipes / Tubes Fittings 43 Clamps (Polypropylene Clamp, U-Bolts) Project Tooling Systems / Stauff / Hydair 44 Hose with end fittings Hydrokrimp / Indo-industrial / Hydrolines / Superseals / Parker 45 Flanges Echjay / NL Hazra / MS Fittings 46 SAE Flange AVIT / Parker / Hyloc / Stauff 47 Electrical Heater Escorts / Alco / Helios 48 Air Breathers Internormen / Parker / Hydac 49 Portable Filter Unit Internormen / Hydac / Rexroth / © 2007 MECON Limited All rights reserved AREA Preferred Makes Page 36 of 37 Oil Lubrication / Descaling Hydraulics / Oil Lubrication / Descaling Hydraulics / Oil Lubrication / Descaling Hydraulics / Oil Lubrication / Descaling Hydraulics / Oil Lubrication / Descaling Hydraulics / Oil Lubrication / Descaling Hydraulics Hydraulics / Oil Lubrication Hydraulics / Oil Lubrication Hydraulics GS-13 General Technical Specification SL. NO. ITEM MAKE Parker PALL / Hydac / Internorman / Parker 50 Contamination Analysis Kit 51 Centrifuge Alfa Laval / Westfalia 52 Vacuum Dehydrator Filtervac / Pall / Parker / Nortek 53 Electrostatic Liquid Cleaner Mobile Motorised PumpMotor-Filter Unit for Oil Filling Chain Pulley Blocks & Hand Operating Traveling Cranes KLEENTEK / Ferrocare PALL / Hydac / Internorman / Parker 56 Spray Nozzles Lechler / Spraying system 57 58 Nitrogen Booster Station Water in Oil detector 59 Lubricating oil 60 Hydraulic oil 61 Flushing Oil 62 Grease 63 Expansion Joint Hydac / Parker IMA / Parker / UCC Indian oil / HP / BP / Castrol / Mobil Exxon Indian oil / HP / BP / Castrol / Mobile Exxon Indian oil / HP / BP / Castrol / Mobile Exxon Indian oil / HP / BP / Castrol / Balmer Lourie ESBI / STANFLEX / ELAFLEX 54 55 © 2007 MECON Limited All rights reserved Batliboi / Moris / WH Brady & Co. Preferred Makes Page 37 of 37 AREA Hydraulics Hydraulics / Oil Lubrication Hydraulics / Oil Lubrication Hydraulics Hydraulics / Oil Lubrication Hydraulics / Oil Lubrication Descaling / Gear boxes Hydraulics GS-13 STEEL STRUCTURES & AUXILIARY FACILITIES (CHAPTER-04) STEEL AUTHORITY OF INDIA LIMITED BHILAI STEEL PLANT GENERAL TECHNICAL SPECIFICATION FOR SUPPLY, FABRICATION, ERECTION SHEETING & PAINTING OF STEEL STRUCTURES (GS – 04) MECON LIMITED RANCHI - 834002 No. MEC/S/1901/11/38/0/00/00/F1889/R2 JULY, 2007 General Technical Specification CONTENTS Sl.No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Description Content sheet Amendment sheet General Description of Work Scope of Work Design of Building Structures Design of Conveyor galleries & Junction Houses Pipe Line Supporting Structures Steel Chimney Standardisation and Uniformity Fabrication of Steel Structures Erection of Structures Welding Specifications Painting of Building Steel Structures General Requirements Inspection of Structures Quality System and Third Party Inspection Permissible Deviations in Assembly of Welded Joints Permissible Deviations in Erection and Fabrication © 2007 MECON Limited All rights reserved Structural Page 1 of 83 Page No. 1 2 3,4 4 to 6 6 to 19 20 to 25 25 ,26 28 29 30 to 42 42 to 50 50 to 56 56 to 60 60 to 62 62 to 64 64 to 71 71,72 72 to 83 GS-04 General Technical Specification AMENDMENT SHEET Sl. No. © 2007 MECON Limited All rights reserved Description Page No. Structural Page 2 of 83 GS-04 General Technical Specification SECTION : 1 GENERAL DESCRIPTION OF WORK 1.1 The general specifications for structural works furnished herein are intended as guidelines for execution of the works satisfying the Owner’s requirements as also complying with all technical norms in totality. This specification is to cover the design, preparation of design drawings and fabrication drawings, supply of all labour as well as materials and construction of all structural work on a turnkey basis for the Project / Works as described in the general conditions of contract. 1.2 Description of various items of work under this specification and nature of work in detail are given hereinafter. The complete work under this scope is referred to as STRUCTURAL WORKS. The detailed scope of works covered under Structural works is given in Section -2. 1.3 The work to be performed under this specification consists of design, engineering , supply, fabrication, erection and cladding, as well as providing all labour, materials, consumables, equipment, temporary works, temporary labour and staff colony, constructional plant, fuel supply, transportation and all incidental items not shown or specified but reasonably implied or necessary for the completion and proper functioning of the plant, all in strict accordance with the specifications, including revisions and amendments thereto as may be required during the execution of the work. 1.4 Supply of all materials including structural steel, roof cladding & sidecladding sheets, fasteners, paints, consumables like gas, electrodes etc. and all other materials as deemed necessary for proper completion of the work, are included in the scope of the Contractor. 1.5 The work shall be carried out according to the design/drawings to be developed by the Contractor and approved by the Owner/Consultant. © 2007 MECON Limited All rights reserved Structural Page 3 of 83 GS-04 General Technical Specification For all buildings and structures, necessary layout and details are to be developed by the Contractor keeping in view the statutory & functional requirements of the plant and facilities and providing enough space and access for operation, use and maintenance. Certain minimum requirements are indicated in this specification for guidance purpose only. However, the Contractor’s offer shall cover the complete requirements as per the best prevailing practices and to the complete satisfaction of the Owner. 1.6 Contractor shall inspect the site, examine and obtain all information required and satisfy himself regarding matters and things such as access to site, communications, transport, right of way, the type and number of equipment and facilities required for the work, availability of local labour, materials and their rates, local working conditions, weather, tidal / flood levels, subsoil conditions, natural drainage, etc. Ignorance of the site conditions shall not be accepted by the Owner as basis for any claim for compensation or extension of time. The submission of a bid by the Contractor will be construed as evidence that such an examination was made and any later claims / disputes in regard to price quoted shall not be entertained or considered by the Owner on account of ignorance of prevailing site conditions. 1.7. Contractor shall comply with all the applicable statutory rules pertaining to Factory act, Fire safety rule of Loss prevention association, Water act for Pollution control, Explosives act etc. Provisions of Safety, health and welfare according to Factories act shall also be complied with. Statutory clearances and norms of State Pollution Control Board shall be followed. Statutory body /Act requirements shall be fulfilled by the Contractor and in case any modifications /additions to the building /Structures are to be made as per the above, shall be carried out by the Contractor at no extra cost to the Owner. SECTION - 2 © 2007 MECON Limited All rights reserved SCOPE OF WORK Structural Page 4 of 83 GS-04 General Technical Specification 2.0. The scope of work shall cover , but shall not be exclusively limited to, the following : - collection of all site related data & conducting site investigations, - design, preparation of all design drawings, fabrication drawings, - obtaining Owner’s/Consultant’s approval on general arrangements and design of structures - dismantling, retrieval, sorting and storing of any existing structures as directed by the owner, if dismantling is a part of the total work - supply of all materials viz, raw steel, sheeting for roof and side cladding, and paints - supply of fasteners like bolts, nuts, washers etc - supply of consumables like electrodes for welding, gases for gas cutting etc - supply of plant & machinery, tools tackles, instruments for fabrication and erection - providing facilities for testing of materials and conducting NDT - providing facilities for transport and handling - deploying requisite skilled and unskilled manpower - making arrangements for all services like approach to site, electricity, water etc - fabrication of structures , their transport and proper storing at site - erection of structures, claddings, gutters, down pipes etc - application of paints at shop after fabrication and at site after erection - providing all reasonable facilities for inspection by Owner/Consultant - conducting NDT as stipulated by the Owner and making test results available to Owner / Consultant for evaluation © 2007 MECON Limited All rights reserved Structural Page 5 of 83 GS-04 General Technical Specification - compliance with primary acceptance tests / inspection, liquidation of defects ; compliance with final acceptance tests / inspection, liquidation of defects; - carrying out field-engineering decisions as desired by the Owner - preparation of “As Built” drawings for all the structures and hand over to the Owner the completed structural work to the Owner’s full satisfaction . - supply of all loading data for RCC foundation, layout drawing, HD bolt insert details and all other necessary information for requirement of Foundation/ RCC work , where future expansion is envisaged , the successful contractor shall furnish load data separately for present and future construction. - any other work deemed incidental for the completion of the overall work but not included in the above detailed scope. SECTION – 3 3.0 DESIGN OF BUILDING STRUCTURES General This specification shall apply to steel work in building and general structural steel work. For technological structures, additional stipulations shall be considered as per technical requirements. 3.1 3.1.0 3.1.01 Design considerations General Structures shall be designed such that they are economical and safe and meet the functional and service requirement of the technological process for which © 2007 MECON Limited All rights reserved Structural Page 6 of 83 GS-04 General Technical Specification they are designed. The architectural planning of the building shall be based on technological requirements. 3.1.02 The structures shall be designed conforming to the relevant safety regulations, Factory Acts, Electricity Rules and stipulations of Statutory bodies as applicable to the project. 3.1.03 Natural ventilation shall be provided ensuring that it does not permit rain water entry into the building. Scope of natural lighting shall be used to the maximum possible extent. 3.1.04 Mild steel gutters and down-pipes with gutter outlets having grating cover shall be provided to carry rain water from roofs of buildings to the drainage system at ground level. All gutters shall be designed as walkable with 600 mm sole width. 3.1.05 Adequate facilities in the form of monorails, hoists, platforms etc. shall be provided to facilitate repair and maintenance of overhead cranes, equipment, etc. Access to these platforms shall be provided by stairs / ladders from the nearest accessible floor or platform. 3.1.06 Access to all floors, gangways and landings shall be by staircases. Access to platforms and landing of secondary importance or where such access is used only rarely, shall be by vertical ladders with safety hoops. Roofs with access shall be provided with safety handrails along the periphery of the roof. 3.1.07 3.1.08 Edges of floors, gangways, stairs and landings shall be provided with safety hand railings. 3.1.09 At gable ends of buildings, platforms shall be provided connecting the walkways at crane gantry level. Floors, gangways and landings shall be covered as follows : 3.1.10 a) Gangways and landings shall have chequered plate with a minimum thickness of 6mm o/p suitably stiffened to meet design load requirements. b) Floors and operating platforms other than the above shall have chequered plate flooring or hot dip galvanised open gratings , or RCC slab resting on steel structural framework , to suit the technological requirements. © 2007 MECON Limited All rights reserved Structural Page 7 of 83 GS-04 General Technical Specification 3.1.11 Protective metal heat shields shall be provided for steel structures exposed to continuous heat radiation of temperature exceeding 150 °C and also where hot metal splashing on structures is likely to occur. 3.1.12 All buildings and their foundations shall be designed so that it shall be possible to extend them in the longitudinal direction at a later date without further strengthening of gable structures. Provision for transverse extension ,if any , shall also be made at the initial stage. 3.1.13 Sheeting on sides and gables shall generally terminate 3.0 m above ground floor level unless required to be otherwise. Sides below this level shall be generally screened by brick walls allowing sufficient air inlet to achieve natural ventilation, unless otherwise required from technological / ventilation requirements. 3.1.14 Connection by permanent bolts to structural elements subject to vibration shall be provided with lock nuts. 3.1.15 For Analysis/ design of steel structural frame work STAAD PRO soft ware shall be used . CD of input files shall be submitted to purchaser / consultant along with the hard copy of the document. 3.2 Elements of Structures 3.2.01 Columns a) At the location of passage/opening through columns web shall be suitably strengthened by vierendeel panel or modified lattice system. b) Shear force at the column base shall be resisted either by shear keys shop-welded to the underside of column base plates or by welding base plate to inserts provided in foundation. c) The level of underside of column base shall be so chosen such that the complete anchor table lies below the finished floor level, thus keeping the shop floor free from projections of anchor tables. © 2007 MECON Limited All rights reserved Structural Page 8 of 83 GS-04 General Technical Specification 3.2.02 Crane Girders a) Crane girders shall generally be of simply supported design, unless continuous crane girders are specifically required. b) Top flange plate shall be welded to web plate with full penetration butt weld with fully automatic submerged arc welding. Bottom flange plate shall be welded to web plate by continuous fillet welds with automatic/semi-automatic welding. c) All intermediate stiffeners shall be fitted against top flange and welded to it by fillet welds/partial penetration butt welds. These stiffeners shall terminate short of bottom flange with at least 25 mm gap. The stiffeners shall be fillet welded to web plate and corners shall be cut suitably to clear thermally affected area of web to top flange connection. d) End bearing stiffener plates of crane girder shall be capable of transmitting the maximum reactions to the columns. The bearing surface of the bearing plate shall be planed/machined to ensure full contact. e) Tension flange of crane girders shall be stabilised by horizontal latticed bracings, where required in order to limit the slenderness ratio of the flange to 150. f) Generally for girders having span 12m and above, vertical auxiliary girder and horizontal girder at crane girder bottom flange level shall be provided. g) h) i) All crane girders shall be checked for fatigue as per IS: 1024 ( latest). j) k) 3.2.03 At crane girder level, walkway shall be provided on both sides. Walkway at column location s shall have minimum clear width of 500mm. Approach by staircase to this level shall be near the maintenance bay. All crane girders and their supporting structures shall be designed for loading from loaded crane in worst position of crab and crane to create most unfavorable loading condition of the girders. For increase of load due to impact and crane load combination including lateral surge shall be taken as per provision of IS 875 ( Part – 2) -1987. Suitable approach to be provided for tightening of bolts of Crane Rail . Approach for Crane Rail fixing shall be properly planned for all types of sections of Crane Girders. Surge Girder walkways and auxiliary beams. © 2007 MECON Limited All rights reserved Structural Page 9 of 83 GS-04 General Technical Specification a) Continuous maintenance walkways with safety hand-railing shall be provided along each column row adjacent to each crane gantry girder. These walkways shall be of non-slip plate construction connected to crane girder top flange by continuous fillet welds. Staircase at every 120m shall be provided from floor for access to this walkways so that stairs are available within 60m from any location. b) Connections between surge girder and the main columns shall be designed to resist load due to lateral braking of crane trolley. c) On the periphery of the building, full length handrails shall be provided along the edge of the maintenance walkway at crane girder level. d) Handrail and its clearance from crane end carriage shall conform to provisions of relevant safety regulations. 3.2.04 Crane Stops a) Crane stops shall be provided at the ends of each crane girder system , or as required to limit the movement of crane as per technological requirements. b) Crane stops shall be bolted to crane gantry girder. c) Only tested rail materials shall be used. Manufacturer’s test certificate, including chemical analysis shall be supplied. d) Rails shall be free from twists, pitting, laminations and any other internal and external defects. The rail shall be straight and the deviation from the straightness shall not exceed + 1.5mm. If necessary the rail shall be cold straightened. e) Unless otherwise specified, the crane rail joint shall be butt-jointed( either by Thermit or fusion welding) or by fishplates . f) For Butt-welding the contractor shall take prior approval of the Purchaser regarding method of edge preparation, welding procedure and sequence of welding to be done. Edge preparation shall be done by oxyacetylene flame and shall be neatly finished by chipping and grinding. g) All position low hydrogen electrodes conforming to IS 814-1991 shall be used for welding. The rail end shall be pre heated to 250 deg. C before welding. The electrode shall be preheated as per manufacture’ s instructions. The welded joint shall be allowed to cool slowly. It is recommended that the initial and intermediate layers of deposit may be by using ferron V , Superchord or equivalent. Top 3mm layer shall be deposited with Duroid 2A or equivalent, to obtain good wearing surface. © 2007 MECON Limited All rights reserved Structural Page 10 of 83 GS-04 General Technical Specification h) The joints shall be free from kinks, twists etc, and shall be grinded properly after welding to ensure smooth running of the crane. i) Method of securing the crane rail to the crane gantry, alignment and expansion joints , if any, shall be subject to Purchaser’ s approval. The crane rail clips shall be preferably forged or pressed from steel plates. 3.2.05 Roof Structures a) The main supporting element for roof shall be roof trusses provided at uniform spacing to suit shop layout. Roof shall be provided with adequately sized roof monitor for natural ventilation, wherever required. b) Roof shall have suitable slope to meet technological as well as rainwater drainage requirements. Hand railings at eaves level and gable ends of the roof of the building shall be provided. c) System of bracings shall be provided in the roof top chord and bottom chord levels along with longitudinal ties to ensure stability and rigidity of the roof structures. Vertical bracings between trusses shall also ve provided wherever required. d) Galvanised wind tie (45x6 mm flat) shall be provided at the free edge of roof sheeting. e) Suitable arrangement of anchors shall be provided at the ridge of roof sheeting for holding lanyards of safety belts. 3.2.06 Roof lighting walkways a) Full length roof lighting walkways, generally 600 mm wide, shall be provided in each bay as required to match the number of rows of roof lights provided in the shop as per technological requirement. b) These walkways shall span between roof truss members and will be decked with chequered plate floor. Walkways shall be provided with handrails on both sides. © 2007 MECON Limited All rights reserved Structural Page 11 of 83 GS-04 General Technical Specification 3.2.07 Roof drainage system a) Roof drainage system shall be designed for maximum precipitation for 5 minutes based on local meteorological data. A factor of safety of 1.3 shall be kept in the design. b) All valley and eaves gutters shall be of pressed plate construction with a minimum sole width of 600 mm so as to function as walkways. c) Eaves gutter shall be provided for eaves height ranging between 10 m to 25 m above apron/ground level. d) The gutters shall be laid to slope towards down-pipes with welded outlets and having grills fitted flush with gutter sole. Slope of gutters and collector pipes shall not be flatter than the following limits : i) Longitudinal slope of gutter 1 : 500 ii) Longitudinal slope of collector pipe 1 : 300 e) Poking holes with cover shall be provided in the down-pipes at suitable intervals as well as at accessible levels, to clean the down-pipes. f) Collector pipes shall be provided with covered manholes at 6 m intervals. g) Eaves gutter shall be provided with safety handrails. h) When rain water falls from higher to lower roof, double layer of sheets shall be provided for the portion of roof sheeting on which rain water falls, provided the drop of roof is in the range of 3 m to 6 m. In case the drop is more than 6 m, independent gutter shall be provided. i) Down pipes shall be spaced preferably at 24 m centres. The down-pipes shall be connected to the gutter with suitably designed hoppers with gratings at sole level of gutter, made of 8 mm dia rounds at 50 mm centers. j) Joints of gutter and collector pipes shall be by welding in order to be leak-proof. © 2007 MECON Limited All rights reserved Structural Page 12 of 83 GS-04 General Technical Specification 3.2.08 Wall Structures a) Wall runners with necessary sag rod arrangements shall be provided to support wall and gable sheeting, including internal partition wall, wherever required. b) Hanging wall posts shall generally terminate at 3.5 m above ground floor level unless required to be otherwise ( Refer Clause 3.1.13 ). c) Gables of buildings shall have wall post spaced at intervals to suit bay width. d) Walls shall be provided with louvres and translucent sheeting at appropriate levels, to provide natural ventilation and lighting. 3.2.09 Floor Frameworks a) Floor beams supporting vibrating equipment shall be designed to avoid resonant frequencies. (Refer clause 3.3.01 (c)) b) Beams along-with framework, shall be provided with both horizontal and vertical bracing (wherever permissible) to achieve overall rigidity. 3.2.10 Vertical bracings a) 3.2.11 Vertical bracings shall be provided on all column rows for each expansion block. b) Vertical bracings shall extend from ground level to roof level and shall be designed to transmit longitudinal forces i.e wind forces, crane tractive forces, seismic forces etc. to the foundation. c) Below crane girder level, for two-legged columns, the bracings shall be of twin system in the plane of each column leg, suitably tied or laced together. Access staircase, walkways, platforms and ladders. © 2007 MECON Limited All rights reserved Structural Page 13 of 83 GS-04 General Technical Specification a) Wherever possible, access shall be provided by means of stairs. b) All walkways and stairs leading to working platforms shall have minimum 1000 mm width of walkways/flight of stair. c) All other walkways and stairs leading to areas for maintenance purpose, or due to restriction of space, shall have a minimum width of 800 mm of walkway/flight of stair, unless required otherwise. d) Staircases shall be generally designed with slope of approximate 37.5° with the horizontal. (in no case the slope shall exceed 40 ° with the horizontal). Intermediate landings shall be provided wherever required such that vertical rise of each flight does not exceed 3000 mm. Risers in one flight shall be equally spaced. e) Walkway floors and stair treads shall be designed with chequered plate ( or non-slip type plates). Ribbed floor/treads may be provided wherever the possibility of accumulation of dust exists, taking care that such provisions do not crate a nuisance to the operating personnel on the shop floor. f) Rise of treads in staircases shall not exceed 200 mm. g) h) A minimum headroom of 2200 mm shall be provided over operating platforms, visitor's galleries, or other areas with possibility of public gathering. In all other platforms, walkways and stairs, a minimum headroom of 2000 mm shall be provided. Only in special cases, local headroom of 1800 mm may be allowed (i.e at intersection with structural members etc.). Cat ladders shall be provided for access, wherever provision of staircase is impractical due to limitations of space, or the access is required very infrequently. i) Wherever the height of cat ladder exceeds 4.0 m, safety cage shall be provided. Intermediate landing shall be provided to cat ladders such that vertical height of single rise does not exceed 8.0 m. j) Cat ladders shall be designed with following provisions : i) Width of rung ii) Minimum rise of rung Maximum rise of rung = 500 mm = 250 mm = 300 mm iii) Minimum clearance from rung of ladder to back of cage (in case of caged ladders) = 700 mm © 2007 MECON Limited All rights reserved Structural Page 14 of 83 GS-04 General Technical Specification iv) Minimum clearance from the centre of cage all round = 350 mm v) Slope of cat-ladders : I. For normal cat-ladders, slope shall be horizontal. within the range of 75°-90° with the II. For ship-type ladders (i.e cat-ladders with short side handrails) the slope shall be within the range of 65°-75° with the horizontal. k) All walkways, platforms and stairs shall be provided with safety handrails. All handrails shall be constructed with steel tubes / angles for posts, top and middle rail and plates/sheets for toe plates. In case of stairs, the toe guards need not be provided. l) The vertical height of hand-railings on walkways and stairs shall be minimum 1000 mm above floor level. m) Hand-railing along edge of roof and gutters shall have a minimum height of 600 mm over top edge of gutters/sheets. In such hand-railings toe guards need not be provided. (only top handrail and mid-rail shall be provided). n) 3.3 Access to roof of the building shall be provided by means of staircases at midway length of the building. Pair of staircases shall be provided with one at the near end and the other at far end length of building. Approach to monitor roof / high bay roof from the roof of the bay approachable by staircases at midway length of the building shall be by means of staircase ( if height of roof > 3m ) or cat-ladder. Approach shall be provided on the roof of the building along the cross-section of the building. Design 3.3.01 Design of structures a) Design of steel structures shall be done in accordance with IS:800-1984 or any equivalent international code of practice that may be applicable. b) Structures subjected to fluctuating/reversal of stress (eg. Crane girders) shall be designed in accordance with IS:1024-1979. c) Resonance in structures : Structures supporting vibratory/reciprocating equipments shall be designed so as to obviate occurrence of resonance. The ratio of applied frequency to natural frequency shall not lie within the range 0.7 © 2007 MECON Limited All rights reserved Structural Page 15 of 83 GS-04 General Technical Specification to 1.5. For wind load calculation the following data may be considered - Basic wind speed ( Vb) at 10 M ht = 39 m/ sec. - Risk co- efficient ( K1) = 1.0 - Terrain ht and Structure size factor(K2) shall be calculated with Category 2. - Topography co- efficient ( K3) = 1.0 Seismic load- Structure shall be designed as per IS- 1893-(Part1) 2002. 3.3.02 Description of design loads Loads considered in design shall allow fully for all aspects of : i) Dead weight of structures, wall, floors, equipment, wiring, machinery, pipe-work, cabling and any item of a permanent nature. ii) Superimposed loads for roofs and floors plus any temporary machinery not allowed within the general superimposed loads. iii) Crane loading. iv) Temperature loads from process requirements because of the position of the structure relative to the heat source or from support of mains, pipes etc. subject to heat. v) Maximum range of temperature variation for climatic conditions = ± 45°C vi) Dust load. vii) Dynamic loads from screens and other such reciprocating machinery. viii) Maintenance hoists on Runway beams. ix) Wind Loads x) Seismic loads xi) From future extensions. xii) Any special erection requirements. xiii) Erection loads on floor and structures 3.3.03 Loading codes © 2007 MECON Limited All rights reserved Structural Page 16 of 83 GS-04 General Technical Specification a) All live loads shall be considered in accordance with IS:875(Part-2)-1987. (Also refer clause 3.3.04) b) Wind loads shall be in accordance with IS:875(Part-3)-1987 and any other consideration specific to the site. c) Seismic loads shall be in accordance with IS:1893- 2002. d) Crane loading to be considered in design shall be as follows : I. As per relevant clause of IS:800-1983. II. IS:875(Part-2)-1987 for conditions not covered in IS:800-1983.3. unless more severe loads have to be considered for technological/operational conditions. e) Crane stopper shall be designed in accordance with clause 6.1.4 of IS:875 (Part-5)-1987. f) In absence of any suitable provision for design loads, any other recognised code of practice may be followed subject to prior approval of the Owner. 3.3.04 Additional Design Loads Besides technological loads, all platforms, walkways, stairs etc. shall be designed for the following live loads : i) ii) iii) iv) v) vi) vii) viii) ix) Walkways and Platforms : 2 KN/m² Visitor's galleries : 4 KN/m² Maintenance platforms : 4 KN/m² including crane level walkway. Staircase and treads : 4 KN/m² Monorail walkways : 4 KN/m² Handrails : 0.75 KN/m run (Horizontal) Ladder : 0.9 KN at middle of rung Dust loads ( for buildings : 0.5 KN/m² and structures located in dusty zone) All structures supporting : Overloading vibrating equipment by 25 % on (motors, fans etc.) Static load unless specified otherwise of Equipment. © 2007 MECON Limited All rights reserved Structural Page 17 of 83 GS-04 General Technical Specification 3.3.05 Combination of loads Various design loads considered shall be combined in accordance with clause 8.0 of IS:875(Part-5)-1987 to give the most severe loading condition for design of structures. 3.3.06 Stress Enhancements Permissible limits of stress may be increased wherever permissible, in accordance with IS:800-1983. 3.3.07 Limiting deflection a) The deflection shall be limited in various elements of structures in accordance with IS:800- 1984 (clause 3.13). b) In addition, the following limitations in deflection shall be observed in design : Vertical Deflection i) Monorail track beams , main floor beams, equipment supporting beams & beams supporting brick walls ii) Main roof trusses, roof girders main floor beams in operating platforms iii) Secondary floor beams : Span / 400 : Span / 400 : Span / 325 Horizontal Deflection i) Crane girders due to surge force: (from one crane only). Span / 2000 ii) Main columns at crane rail level: in transverse direction due to action of crane surge (for surge force consider one crane for single bay and one crane each on adjacent aisles for multi-bay buildings) H / 2500 iii) Open gantry for condition as in: H/4000 (ii) above. © 2007 MECON Limited All rights reserved Structural Page 18 of 83 GS-04 General Technical Specification Where H = Height of Column from bottom of base plate to crane rail level. c) All deflections shall be calculated without dynamic factor. 3.3.08 Camber Wherever excessive deformation is likely to cause operational problem or is aesthetically not agreeable, camber shall be provided to neutralise the effect of deformation due to dead load plus 50 % of imposed loads. 3.3.09 Expansion joints a) Longitudinal and transverse expansion joints shall be provided in buildings and structures in accordance with IS:800-1984 (clause 3.14). b) Expansion joints shall be formed by providing double rows of columns, with overhanging gantry girders, secondary roof and wall framing being detailed to allow the maximum calculated movement for the specified temperature variation. 3.3.10 Miscellaneous design requirements a) The minimum thickness of structural steel elements shall be in accordance with IS:800-1984 (clause 3.8). Minimum size angle shall be ISA50x50x6. b) The diameter of structural bolts shall not be less than 16 mm except for those securing roof and wall sheets, windows, doors and stitching of thin coverings. For bolted joints, at least two bolts per joint shall be provided. c) The size of fillet welds shall not be less than 5 mm. d) Main structural elements shall be welded continuously. Intermittent welding shall be used only on secondary members which are not exposed to weather or other corrosive influence. e) i) Field connection and splices shall be made as follows : by welding © 2007 MECON Limited All rights reserved Structural Page 19 of 83 GS-04 General Technical Specification ii) by permanent bolts (for secondary members such as purlins, wall etc.) iii) runners by High Strength Friction Grip bolts (HSFG) 3.4 DESIGN OF CONVEYOR GALLERIES AND 3.4.0 Design Considerations JUNCTION HOUSES 3.4.01 The general parameters for conveyor galleries shall conform to the provision of IPSS:2-03-001-81 (Interplant Standards : Steel Industry - Design parameters for galleries and tunnels for belt conveyors in steel plant), and provisions of IS : 11592-1985 unless specified otherwise in Technical Specifications. The structures shall be designed so as to meet functional requirements and shall provide space for operation, maintenance and removal of machinery and give the workers good and safe environment. 3.4.02 Gallery floors shall be of pre-cast R.C.C slabs / Chequered plates ( as required ) supported on steel beams. 3.4.03 Steps shall be provided (rise not exceeding 130 mm) along the walkways if the gallery slope exceeds 12°. In case the slope of gallery is between 6° to 12°, suitable ribs shall be provided on floor (without any sharp edges) at 250 to 300 mm intervals. 3.4.04 Provisions shall be made for emergency exit from galleries to ground level and also for cross-over above conveyor at 100 m intervals (maximum). The width of cross over shall not be less than 600 mm. 3.4.05 Roof and side walls of conveyor galleries shall be covered with GCS/ Aluminium sheets. with a provision of gap of 300 mm below roof and 150 mm from top of floor level on the side wall for ventilation. 3.4.06 Adequate provision for natural light inside conveyor gallery shall be made through side walls by providing translucent sheets (FRP sheets as per IS: 12866-1989). Every sixth sheet on side wall shall be FRP sheet and shall be staggered on opposite wall. © 2007 MECON Limited All rights reserved Structural Page 20 of 83 GS-04 General Technical Specification 3.4.07 Roof slopes of conveyor galleries shall be 1:5 (1 vertical, 5 Horizontal). 3.4.08 The level of underside of the base plate of gallery supporting trestles shall be 300 mm above the average ground level of the surrounding area. 3.4.09 Protective hand railing shall be provided along gallery walkways, open platform, stairways, landings, edges of walkways when the gallery is not enclosed, and around erection openings, if any, to ensure safety of operating personnel. 3.4.10 Conveyor galleries longer than 150 m shall be provided with expansion joints with twin trestles/supports. Each expansion block shall have fixed support/rigid trestle with adequate arrangement (provision of top chord and bottom chord bracing to gallery girder etc.) for transferring the transverse and longitudinal forces to the foundation. 3.4.11 Gallery girders near junction house shall be preferably supported on trestle located as close to the junction house as possible, with part of gallery girder between junction house and trestle cantilevered from the trestle. Supporting gallery girders on junction house shall be generally avoided. 3.4.12 The underside of the belt conveyor shall be fully covered with 3 mm sheet in case of conveyor is located within the boundaries of the plant. Wherever such covering is not provided (as in case of the mines area or cross country), the covering must be provided where the gallery crosses roads, railway lines or areas of public gatherings. 3.4.13 Conveyor gallery over hot metal track : When underside of gallery is at less than 12m height from track level, heat shield shall be provided below gallery as well as on sides for a width of track 8 m ( i.e. 4 m on either side of center line of the track ). 3.4.14 When conveyor gallery crosses above or below H.T cables, a minimum clear distance of 1.0 m between the structural elements/cladding and HT cables shall be maintained. 3.4.15 When the conveyor bridge passes over plant roads, clearance between the road surface and the lowest points of the bridges shall not be less than 4.5 m or the height needed for the passage of the largest individual components of the plant equipment, whichever is the larger. 3.4.16 The junction house shall be designed to suit the technological requirements. Number of floors, height of building etc. shall be decided accordingly. © 2007 MECON Limited All rights reserved Structural Page 21 of 83 GS-04 General Technical Specification 3.4.17 In general the junction house shall be designed as framed structures on shorter span side and vertically braced on longer side to achieve stability. 3.4.18 Floor of junction houses shall be of RCC slab supported on steel beams, unless required otherwise from technological consideration. The RCC slab will be connected to steel beams through suitable lugs. 3.4.19 Roof and side covering of junction houses shall be with GCS/Aluminium sheets / troughed colour coated sheets as specified. Roof slope shall be 1 : 5 ( 1 Vertical : 5 Horizontal). 3.4.20 Suitable access staircase and safety hand railing shall be provided to all floors of junction houses. 3.4.21 When hydro-washing of floor of junction house is envisaged , the floor beam supporting RCC slab shall be laid to a suitable slope to achieve the same, wherever the same is not practicable to achieve through screed concrete. (Minimum slope of floor shall be 1.5%). 3.4.22 Wall sheeting shall generally start from the lowest working floor and extend up to roof level with louvres at each floor level to ensure adequate natural ventilation. 3.4.23 Monorails for maintenance hoists shall be provided for maintenance and repair of various equipments located on the floors. Components of structures 3.4.24 Gallery Trusses and Roof a) Gallery truss shall be of latticed type construction and shall support roof (for covered galleries) as well as floor deck supporting conveyor system. b) The trusses shall be adequately braced at top and bottom chord level to transfer the horizontal wind forces to end portals. 3.4.25 Stringer Beam These beams shall be suitably spaced to support the conveyor stringer post and shall deliver load to gallery trusses. Walkways on either side of the conveyor shall also be supported on these stringer beams. © 2007 MECON Limited All rights reserved Structural Page 22 of 83 GS-04 General Technical Specification 3.4.26 Supporting Trestles Intermediate trestles shall be two legged and shall deliver loads from gallery trusses to the foundations. In addition, four legged trestles shall be provided which will act as fixed support to transmit all longitudinal forces between expansion block, in addition to other forces. 3.4.27 Junction Houses a) Floors - Floor beam layout shall be arranged to suit equipment layout as well as equipment anchoring system. b) Columns - In addition to loads from floor and roof, columns shall be designed to transmit horizontal load due to belt tension/snapping of belts to the foundation. 3.4.28 Belt Tensioning Device Suitable structures shall be provided to accommodate belt-tensioning device which may be located either under the conveyor gallery or in the junction house itself. 3.4.29 Wall Structures a) Wall runners with necessary sag rods shall be provided to support wall sheeting in conveyor galleries and junction houses. b) Wall sheeting and louvres - refer clause 3.2.08 3.4.30 3.5 3.5.0 b) Access stairs, walkways, platforms, ladders, hand railing etc. - These shall be provided in accordance with clause 3.2.11 of this specification. Design of Structures. a) Design of steel structures shall be done in accordance with IS:800-1984. In absence of specified dynamic factor to be considered for the load from the belt conveyor, a dynamic factor of not less than 1.3 shall be considered for the design of floor beams and gallery girders. © 2007 MECON Limited All rights reserved Structural Page 23 of 83 GS-04 General Technical Specification c) Gallery trusses and stringers as well as floor beams of junction house shall be checked for obviating occurrence of resonance and shall be designed in accordance with clause 3.3.01(c). d) For wind load consideration the following may be considered : - Basic wind speed (vb) at 10 M ht = 39 m/ s. - Risk co-efficient ( K1) = 1.0 - Terrain ht and structure size factor ( K2) shall be calculated with category 2. - Topography co- efficient (K3 ) = 1.0 e) Seismic load – structure shall be designed as per IS 1893 ( Part 1) 2002. site is located in zone II. 3.5.1 Description of loads and loading codes Unless specified otherwise hereinafter, all the live loads shall be considered in accordance with IS:875 (Part-2)-1987. 3.5.01 3.5.02 Wind loads shall be considered in accordance with IS:875 (Part-3)-1987. 3.5.03 Seismic loads shall be considered in accordance with IS:1893-1984. 3.5.04 Live loads from conveyor on the gallery floor shall be as per conveyor suppliers load data. 3.5.05 While designing the fixed support/rigid trestles in an expansion block of conveyor gallery the following loads (in addition to wind load) shall be considered. a) Forces due to difference in frictional resistance of top and return idle rollers of conveyor. b) Forces due to inertia of rollers at the time of starting of conveyor belt. c) Break down load caused by snapping of belt (in case of multiple conveyors, snapping of one belt at a time) shall be considered. d) Special loads if any Gallery girders and floor shall be designed for the following live loads, inclusive of spillage loads on floors. 3.5.06 a) Walkway/Supporting beams for floor - 4.0 KN/m² b) Under the conveyor belt © 2007 MECON Limited All rights reserved - 0.75 KN/m² Structural Page 24 of 83 GS-04 General Technical Specification c) Gallery girder, for floor load of - 3.0 KN/m² Dust load on roof of junction house and conveyor galleries shall be considered as follows : 3.5.07 a) For building and structures located at a distance of 300 m from the dust producing units - 0.5 KN/m² b) At a distance of 300 m to 800 m from the dust producing unit - 0.25 KN/m² 3.5.08 As per technological requirements, provision of supporting the following, and load arising thereof shall be considered in the design of conveyor gallery. a) Ventilation duct. b) Electrical cables/cable racks. c) Fire Fighting equipment. 3.5.09 Junction house floors shall be designed for the following loads : a) Live load on floor - 4.0 KN/m² b) Tension from conveyor belt c) Load due to equipment located on floor. d) Load due to jamming of chutes. e) Erection loads anywhere on the floor. 3.5.10 Combination of loads The various loads specified shall be combined in accordance with clause 8.0 of IS:875 (Part-5)-1987 to give the most severe loading condition for design of structures. © 2007 MECON Limited All rights reserved Structural Page 25 of 83 GS-04 General Technical Specification 3.5.11 Stress enhancements Permissible limits of stress may be increased, wherever permissible, in accordance with IS:800-1984. 3.5.12 Limiting deflection a) The deflection shall be limited in various elements of structures in accordance with clause 3.13 IS:800-1984. b) In addition following limitation in deflection shall be observed in design : i) Gallery Trusses - Span / 400 ii) Top of End portal of gallery truss - H / 325 where H = Height of portal above beams iii) Traverse deflection of of top of supporting Trestle 3.6 3.6.0 - H/1000 where H = Height of trestle above foundation. PIPLINE SUPPORTING STRUCTURE Design considerations 3.6.01 Bridges shall be provided to support pipelines of smaller diameters for which maximum permissible span is less than the distance between supporting trestles. 3.6.02 Trestles which are designed to transmit longitudinal loads (along the length of pipeline) to the foundation, shall be four legged construction. Other trestles which transmit only the vertical load to the foundation shall be two-legged construction. © 2007 MECON Limited All rights reserved Structural Page 26 of 83 GS-04 General Technical Specification Access stair and platforms shall be provided for maintenance of equipment installed in the pipeline (eg. valves etc.). Maintenance walkways with handrailing shall also be provided along the pipeline, wherever required. Provision of access stairs, walkways platforms, hand-railing etc. shall conform to clause 3.2.11 of this specification. 3.6.03 3.7 Design of Structures 3.7.0 Design of steel structures shall be done in accordance with IS:800-1984. 3.7.01 Unless otherwise specified hereinafter, all live loads shall be considered in accordance with IS:875 (Part-2) 1987. 3.7.02 Wind load shall be considered in accordance with IS:875 (Part-3)-1987. 3.7.03 Seismic loads shall be considered in accordance with IS:1893-2002. 3.7.04 In addition, pipeline, bridge and supporting trestle shall be designed for the following loads : a) Weight of liquid or condensate, as is appropriate for pipeline. b) Weight of valves, compensators, fittings etc. in addition of self-weight of pipe. c) Load due to thermal expansion of pipeline 3.7.05 Maintenance platforms shall be designed for a service load of 4 kN/sq.m 3.7.06 Combination of loads The various loads specified shall be combined in accordance with clause 8.0 of IS:875 (Part-5)-1987 to give the most severe loading condition for design of structures. 3.7.07 Stress enhancements Permissible limits of stress may be increased, wherever permissible, in accordance with IS:800-1984. 3.7.08 Limiting deflection © 2007 MECON Limited All rights reserved Structural Page 27 of 83 GS-04 General Technical Specification a) Deflection of gallery bridge structure shall be limited to Span/400. b) Traverse deformation of trestle shall be limited to H/1000 where H = Height of trestle above foundation level. c) The deflection of other elements of structures shall be limited in accordance with clause 3.13 of IS:800-1984. 3.8 3.8.0 STEEL CHIMNEY General This specification shall apply to design of self supporting steel chimneys. 3.8.1 Design Consideration a) Lining shall be provided in chimney shell as per technological requirements. In the case of lined chimneys, checking for stress and resonance due to wind shall be done for both the conditions i.e lined and unlined. b) Annular platforms with minimum clear width of 1200mm shall be provided at locations of environment monitoring equipment, in addition to the stipulations of IS:6533 (Part-2)-1989. Landing/resting platforms to ladders shall be provided at intervals not exceeding 10.00 M where annular platforms are provided at intervals of height greater than 10.00 M. c) Approach to platforms shall be with ladders with safety cages. (Refer Clause 3.2.11(j) of this specification. d) Chimneys shall be provided with adequate number of Painter's trolleys for inspection and maintenance unless categorically agreed to otherwise with Owner. In case where Painter's trolley is not provided, suitable alternative facility shall be provided for inspection and maintenance. e) Chimneys shall be fitted with helical strakes of three rail system, and shall be strong enough to withstand the additional wind load from the strakes. 3.8.2 Design a) Steel chimneys shall be designed in accordance with IS:6533(Part-2)-1989. © 2007 MECON Limited All rights reserved Structural Page 28 of 83 GS-04 General Technical Specification b) Elements like platforms, hand-rails, ladders, anchor bolts etc. shall be designed in accordance with IS:800-1984. c) For wind and seismic refer clause 3.3.01 (d) and (e) . 3.8.3 Limiting Deflection The maximum deflection at the top due to the action of wind, without considering the dynamic factor shall not be greater than h/200, where h is the unsupported height of the chimney. 3.9 3.9.0 STANDARISATION AND UNIFORMITY General Every endeavour shall be made to achieve standardisation and uniformity amongst the steel structures of different units of the plant. 3.9.1 The following items shall be kept in view in design of structures : a) Uniform layout module shall be adopted to the extent possible consistent with economy. It is suggested to adopt a basic module of 3 m for building width and 6 m for column spacing along building length. b) Uniform slopes of roofs matching with existing buildings unless specifically required otherwise for any particular unit. c) d) Provision of expansion joints by using twin columns. Uniform adoption of clearance between structures and moving parts of equipment. e) Provision of adequate natural ventilation by using louvres (canopy like structures) at appropriate location and roof monitors/natural ventilation systems at roof. © 2007 MECON Limited All rights reserved Structural Page 29 of 83 GS-04 General Technical Specification FABRICATION OF STEEL STRUCTURES 4.0 4.1 Drawings 4.1.1 The Contractor shall prepare design drawings indicating general arrangement, members, sections and details of important joints, fabrication drawings, erection drawings, bill of materials, drawing office despatch lists / shipping documents, schedule of bolts and nuts and as built drawings. All drawing work shall be in metric system and all writing work shall be in English. Drawings shall be prepared using Autocad software. 4.1.2 The fabrication drawings shall show full length layout with all connecting members and connections marked thereon. The fabrication drawings shall include all the necessary blown-up details required for the correct fabrication of the structures to meet the design requirements. These drawings shall be made in conformity with the best modern practices and with due regard to speed and economy in fabrication and erection. Each erection piece shall be clearly identified by an erection mark in these drawings. 4.1.3 The preparation / detailing of fabrication drawing shall be complete in all respects. In the case of bolted connections, the bolt dia., the hole dia., © 2007 MECON Limited All rights reserved Structural Page 30 of 83 GS-04 General Technical Specification the actual location of holes and the coordinating scheme with connecting/ matching elements shall be clearly indicated. As far as possible, uniformity in the bolt dia shall be maintained. Where HSFG bolts are used, method of surface preparation shall be indicated. In case of welded constructions, the size and length of welds along the relevant weld lines should be distinctly marked. The length specified shall be the effective length excluding end crates. For all butt welds, details of appropriate edge preparation shall be indicated. 4.1.4 Detailing of structural steel members subjected to dynamic loading shall be so as to keep the stress concentration to a minimum. Cross welding shall be avoided as far as practicable. 4.1.5 For bolted connections subjected to dynamic loading, lock nuts or spring washers shall be used in addition to plain washers. 4.1.6 Erection drawings shall consist of line diagrams showing every detailed member in position with the respective erection mark. Erection marks shall appear on the left end of the members as detailed. All steel members shall be erected with marks in the same relative position as shown in plan or elevation. All loose members shall either be given part marks or wired on to the main erection mark for despatch. 4.1.7 The erection clearances for cleat-connected ends of members connecting steel to steel shall preferably not be greater than 10 mm. at each end. The erection clearance at ends of beams shall not be more than 20mm. at each end but where for particular reasons greater clearance is necessary, suitably designed seats shall be provided. 4.1.8 The fabrication drawings shall be prepared in such a manner that structures are despatched with maximum transportable lengths and work involved at site is minimum. Steelwork shall be shop-fitted and shopassembled as far as practicable. 4.1.9 All edge preparations for welding shall conform to IS:9595. 4.1.10 The contractor shall ensure correctness & completeness of fabrication drawings. 4.2 Material of Construction © 2007 MECON Limited All rights reserved Structural Page 31 of 83 GS-04 General Technical Specification 4.2.1 All steel and other materials used for steelwork and in association with steelwork shall conform to appropriate Indian standards. Only tested materials shall be used unless written authority is obtained for the use of untested materials for certain secondary structural members. Unless otherwise specified in the drawings a) All rolled sections and plates up to & including 20 mm thickness shall conform to Grade "A” as per IS : 2062. b) Plates of thickness above 20 mm and Plated structures subjected to dynamic loading shall conform to Grade "B” as per IS: 2062. c) For High Tensile steel requirements, material conforming to IS:8500 or SAIL- MA (HYA or HYB) shall be used. 4.2.2 Steel sheets shall conform to IS : 1079. 4.2.3 Steel tubes for structural purpose shall conform to IS : 1161 (of Grade Yst 240) 4.2.4 Corrugated Galvanised Sheets shall conform to IS:277 with appropriate Zinc coating for the selected thickness of sheet on roof and sides. 4.2.5 Aluminium industrial toughed sheets conforming to IS : 1254 shall be used as follows : i) In roof - 0.91mm thick ii) In side walls - 0.71mm thick 4.2.6 Translucent sheets shall be fibreglass reinforced polyester sheets matching profile as per IS:12866. 4.2.7 Colour coated sheets shall be as per appropriate standard. All roof ,monitor roof galvanised / zinc aluminium colour coated sheets of total coated thickness (TCT) of 0.65 mm with base metal yield strength of 240 MPa or alternately sheets having TCT of 0.5mm with base metal yield strength of 550 MPa. All side sheets , monitor sides colour coated sheets of total thickness (TCT) of 0.6 mm with base metal yield strength of 240 MPa or alternately sheets having TCT of 0.5mm with base metal yield strength of 550 MPa. Ridging/ Flushing : colour coated sheets TCT of 0.8 mm with base metal yield strength of 240 MPa or alternately sheets having TCT of 0.5 mm with base metal yield strength of 550 MPa. For all above, minimum zinc deposition shall be 150 gms per sq.m. © 2007 MECON Limited All rights reserved Structural Page 32 of 83 of GS-04 General Technical Specification 4.2.8 Gutters shall be of copper bearing steel conforming to Grade "A" as per IS :2062 4.2.9 Crane Rails shall conform to IS : 3443. 4.2.10 All black bolts, nuts and locknuts shall conform to IS : 1363 and IS : 1364 (for precision and semi precision hexagonal bolts) of property class 6.4 unless otherwise specified. Washers shall conform to IS : 6610 4.2.11 All tapered washer shall be as per IS:5372 for channels, and IS:5374 for Joists. Spring washers shall conform to IS:3063. 4.2.12 All HSFG bolts shall conform to IS : 3757. Assembly of joints using HSFG bolts shall conform to IS : 4000. Nuts and washers for HSFG bolts shall be as per IS:6623 & IS:6649 respectively. 4.2.13 Covered electrodes for arc welding shall conform to IS: 814. Coding of electrodes shall be as follows : a) b) ER421 ‘C’ X for mild steel of Grade 'A’ and Grade 'B’ as per IS : 2062 EB 542 ‘C' H3X for Mild steel of Grade 'B’ as per IS 2062 for dynamically loaded structures (arising out of crane, vibratory screen, equipments etc.) ‘C' is the value of the current as recommended by the electrode manufacturer. 4.2.14 Certified mill test reports of materials used in the work shall be made available for inspection by the Owner / Consultant upon request. 4.2.15 All materials shall be straight and if necessary before being worked shall be straightened and / or flattened by pressure including de-coiling of plates unless required to be of curvilinear form and shall be free from twists. 4.2.16 The MS / GI gratings shall be electro-forged and shall be of approved brand and manufacturer unless otherwise agreed to by the Owner. The type of grating selected shall be based on the loading in the area in which the grating is provided and shall be subject to approval of Owner. 4.3 Material preparation © 2007 MECON Limited All rights reserved Structural Page 33 of 83 GS-04 General Technical Specification 4.3.1 Cut edges shall be finished smooth by grinding or machining wherever necessary. Sufficient allowance (3 mm to 5 mm ) should be kept in the items in case machining is necessary. 4.3.2 Cutting may be effected by gas cutting, shearing, cropping or sawing. In gas cutting of high tensile steel, special care is to be taken to leave sufficient metal to be removed by machining so that all metal that has been hardened by flame is removed. 4.3.3 Sufficient shrinkage allowance (@ 1mm/M) shall be kept wherever heavy welding is involved. 4.3.4 Straightening and bending shall be done in cold condition as far as practicable. 4.3.5 If required, straightening and bending may be done by application of heat between 900°C and 1100°C. Cooling down of the heated item shall be done slowly. 4.4 Drilling and punching of holes 4.4.1 Drilling and punching of holes for bolts shall be done as per clause no.11.4.4 of IS:800:1984, unless otherwise specified by the Owner. 4.4.2 Drifting of holes for bolts during assembly shall not cause enlargement of holes beyond permissible limit or damage the metal. 4.4.3 Holes for bolted connection should match well to permit easy entry of bolts. Gross mismatch of holes shall be avoided. 4.4.4 Permissible deviation in holes for mild steel bolts of normal accuracy and high strength bolts are given in the ANNEXURE-A. 4.5 Assembly for fabrication © 2007 MECON Limited All rights reserved Structural Page 34 of 83 GS-04 General Technical Specification 4.5.1 Fabrication of all structural steelwork shall be in accordance with IS:800-1984 and in conformity with various clauses of this specification, unless otherwise specified in the drawings. 4.5.2 Fabrication of structures shall preferably be taken up as per the sequence of erection. 4.5.3 All erection units shall bear erection mark no. and reference drg no. at a prominent location on the structures for easy identification at site. 4.5.4 Fabricated structures shall conform to tolerance as specified in this standard and in IS:7215-1974. In case of contradiction, tolerances specified in this standard shall prevail. 4.5.5 All the components of structures shall be free from twist, bend, damage etc, 4.5.6 Assembly of structures shall be carried out by using suitable jigs and fixtures in order to obviate distortion during welding. 4.5.7 Cutting of items specially for truss, bracing, bunker, hopper, galleries surge girder, portal etc, shall be done only after checking of sizes as per Layout. 4.5.8 Surface, wherever machining is specified , shall be either planed or milled or ground to ensure maximum contact. 4.5.9 If end-milling or machining is planned after the assembly is over, sufficient allowance (5 mm to 15 mm) shall be kept in the items where milling/machining is to be done. 4.5.10 If pre-bending of the plate is required to avoid welding distortion, it shall be done in cold condition. 4.5.11 Sufficient trial assembly of fabricated components (despatch elements) shall be carried out in the fabrication works to control the accuracy of workmanship. 4.5.12 Where necessary, washers shall be tapered or otherwise suitably shaped to give the heads of nuts and bolts satisfactory bearing. 4.5.13 The threaded portion of each bolt shall project through the by one thread. © 2007 MECON Limited All rights reserved Structural Page 35 of 83 nut at least GS-04 General Technical Specification 4.5.14 Tolerance of assembled components of structures are given in TABLE 4.5.15 Permissible deviations from designed (true) geometrical form of the despatch elements shall be in accordance with IS:7215-1974. 4.6 Method of Construction 4.6.1 The method of construction shall be either by welding or by bolting limiting the site work to the minimum possible. 4.6.2 Bolt diameter shall not be less than 16mm. except for bolts securing roof and wall sheeting, windows, doors and stitching of thin coverings. For bolted joints, min. two bolts shall be used. 4.6.3 The size of fillet welds shall not be less than 5mm for load-bearing joints. 4.6.4 Main structural elements shall be welded continuously. Intermittent welds shall be used only on secondary members, which are not exposed to weather or other corrosive influence. 4.6.5 Connections and splices shall be made by welding, or by bolting with appropriate property class.Black bolts shall be used in connections and attachments of secondary members such as purlins, wall girts, etc. Bolts shall be prevented from loosening by means of lock nuts, single coil spring washers or similar devices. 4.6.6 Method of splicing shall be similar to the method of construction adopted for structures. All splices shall be full-strength splice unless exception is specified. 4.6.7 Roof and wall sheets shall be fixed to purlins and wall girts by stainless steel top speed screws/galvanized J- hook bolts, each complete with neoprene and stainless steel /galvanized washers. The connections shall ensure water-tightness into the buildings. The spacing of these screws/bolts shall be sufficient to prevent uplift of sheets by suction. The roof and wall sheets shall be stitched together at their edges by using studs, rivets or screws. The end and side overlaps of sheeting shall be sufficient to prevent ingress of rainwater. End lap shall not be less than 75mm and side lap shall not be less than one and half corrugation for © 2007 MECON Limited All rights reserved Structural Page 36 of 83 GS-04 General Technical Specification GCS sheets. For troughed aluminium recommendations shall be followed. sheets manufacturer’s 4.7 Structural steel connection 4.7.1 The Contractor shall be responsible for the design and the detailing of all connections. The design of connections shall provide for adequate strength for the transfer of force in the structural elements indicated on the design drawings. For purposes of detailing of connections, the allowable stresses in material, bolts and welds shall be as per IS:800 and IS:816 or as specified in the design drawings. 4.7.2 For all full strength butt welding of plates and sections thicker than or equal to 10 mm, edge preparation shall be done and got approved by the Owner / Consultant. 4.7.3 Two numbers of washers shall be used for all bolted connections, one washer bearing against the head and other bearing against the nut. 4.7.4 The magnitude of forces shown on design drawings shall be used at face values with no reductions for connections. 4.7.5 If extra joints are to be provided in column, crane girder etc, prior approval on the same shall be obtained from the Owner / Consultant However , as general guidance, the following is suggested : - Splice joint on column and crane girder shall be of full strength butt weld, and, wherever possible, shall be located at the section of minimum or substantially lesser stress. - Splice joints of web and flange should be sufficiently staggered in position. 4.7.6 All penetration for piping, conduit, cable trays, etc., through grating or plate flooring shall be cut and suitably banded in the field, except when such penetrations are dimensioned in the drawings in which case they shall be shop cut and banded. © 2007 MECON Limited All rights reserved Structural Page 37 of 83 GS-04 General Technical Specification 4.8 Fabrication 4.8.1 Fabrication of all structural steelwork shall be in accordance with IS:800 or their equivalent foreign national standard of the country of origin of supply unless otherwise specified, and in conformity with various clauses of the Technical Specification. 4.8.2 Wherever practicable and wherever perfect matching of parts is required at site, members shall be shop assembled before despatch to minimise site work. Parts not completely assembled in the shop shall be secured, to the extent possible, to prevent damage during despatch. 4.8.3 All pieces shall be properly identified and bundled for transportation to work site. Care shall be exercised in the delivery, handling and storage of material to ensure that material is not damaged in any manner. Materials shall be kept free of dirt, grease and foreign matter and shall be protected from corrosion. All materials shall be stored properly on skids above the ground which shall be kept clean and properly drained. Girders and beams shall be placed upright and stored. Long members such as columns and chord members shall be supported on skids spaced near enough to prevent damage due to deflection. 4.8.4 Bolts shall be furnished according to bolt lists showing the location of their use and additional bolts shall be supplied to cover wastage. 4.8.5 All fabricated pieces shall bear erection mark numbers painted/punched according to appropriate erection and shop drawings at a prominent location on the structure for easy identification. 4.8.6 All workmanship shall be in accordance with the best practice in modern structural shops. Greatest accuracy shall be achieved in the manufacture of every part of the work and all identical parts shall be strictly interchangeable. 4.8.7 Shearing or flame cutting may be used at the Contractor's option provided that a mechanically controlled cutting torch is used for flame cutting and that the resulting edges are clean and straight. 4.8.8 Unless clean square and true to shape all flame cut edges shall be planed/cleaned by chipping or grinding. Where machine flame cutting is permitted for high tensile steel, special care shall be taken to leave sufficient margin and all flame hardened material shall be removed by machining/edge grinding. © 2007 MECON Limited All rights reserved Structural Page 38 of 83 GS-04 General Technical Specification 4.8.9 Wherever shearing is used for cutting to size, sheared members shall be free from distortions at sheared edge. 4.8.10 The ends of all girder stiffeners shall be in contact with the compression flange and shall be planed or ground to fit tightly against flange plates unless otherwise stated on the drawings. Care shall be taken to ensure full bearing of the stiffeners at the supports by machining the contact surfaces of both bearing stiffeners and bearing plates. The ends shall not be drawn or caulked. 4.8.11 Column splices and butt joints of struts and compression members depending on contact for stress transmission shall be accurately machined and close butted over the whole section with a clearance not exceeding 0.1 mm locally at any place. 4.8.12 In column cap and bases, the ends of shafts, should be accurately machined so that the parts connected butt over the entire surface of contact. Care should be taken so that these connecting members are fixed with such accuracy that they are not reduced in thickness by machining by more than 1.0 mm. On secondary members, where sufficient gussets and welds are provided to transmit the entire loading, the column ends may not be machined subject to the approval of the Owner / Consultant. 4.8.13 Holes for permanent black bolts shall not be more than 1. 5 mm larger than the nominal diameter of the black bolts unless specified otherwise. All holes for turned and fitted bolts shall be sub punched or drilled and reamed at site under assembly of connected parts to a tolerance of +0.3 mm unless specified otherwise. Holes in purlins, side-sheeting runners, packing plates and lacing bars may be punched full size. Holes in light framing with the exception of joint holes, may be punched full size. All punching and sub-punching shall be clean and accurate and all drilling free from burrs. In block/batch drilling, parts shall be separated after drilling and the burrs removed. No hole shall be made by gas cutting process. 4.8.14 The component parts shall be so assembled that they are neither twisted nor otherwise damaged and specified cambers, if any, shall be provided. No drifting of hole shall be permitted except to draw the parts together. Drifts used shall not be larger than the nominal diameter of the bolt. Drifting done during assembling shall not distort the metal or enlarge the holes. Sufficient trial assembly shall be carried out in the fabrication works to prove the accuracy of workmanship of the and the number of such trials required shall be at inspector's discretion. © 2007 MECON Limited All rights reserved Structural Page 39 of 83 GS-04 General Technical Specification 4.8.15 Where necessary, washers shall be tapered or otherwise suitably shaped to give the heads and nuts of bolts a satisfactory bearing. The threaded portion of each bolt shall project through the nut by at least one thread. 4.8.16 In all cases where the full bearing area of the bolt is to be developed, the bolt shall be provided with a washer of sufficient thickness, under the nut so as to avoid any threaded portion of the bolt being within the thickness of the parts bolted together. Column bases and caps, shall be in one solid piece, and except when cut from plates with true surfaces, shall be accurately machined over the bearing surfaces, and shall be in effective contact over the whole area of the machine end of the stanchion. 4.8.17 Each piece shall be distinctly marked before delivery, in accordance with an approved marking diagram and shall bear such other marks as well to facilitate erection. For easy identification at site a small distinguishing mark for each building shall be painted at each end of every member before despatch from fabrication shop. The fabricated steel work shall be despatched in sequence as per agreed programme and for such portion as may be found convenient for erection or as ordered by the Owner / Consultant. 4.8.18 The Contractor shall provide suitable packing wherever necessary to guard against damage during handling and transportation to site. All fabricated parts shall be adequately braced to prevent damage during transit. 4.8.19 The tolerances for fabrication of steel structures shall generally conform to IS:7215 and to suit the technological requirements as specified by the equipment supplier. 4.8.20 Any fabrication work which is considered not to be in keeping with the Technical Specification forming the Contract, or in absence of Technical Specification with recognized good practice, shall be rectified /replaced /corrected at the Contractor's expense as directed by the Owner / Consultant. Site fabrication work shall also conform to all specifications, stipulations, terms and conditions applicable for shop-welded structures as mentioned above. 4.8.21 Fabrication of steel structures shall not be allowed inside the plant premises. 4.9 Wastage & Accountability © 2007 MECON Limited All rights reserved Structural Page 40 of 83 GS-04 General Technical Specification 4.9.1 For the purpose of accounting of materials where the same is supplied by the Owner, free or on cost recoverable basis, the following wastage including rolling margin, invisible wastage and cut pieces of less than one metre length and plates with lesser dimension less than 300 mm shall be allowed. a) Structural Steel : i) Sections - 5% on the quantity by weight computed, based on Fabrication drgs. ii) Plates - 7.5% on the quantity by weight computed, based on Fabrication drawings. b) Other materials : 5% on the quantity by weight computed, based on manufacturing drawings. For all cut pieces ( plates & sections ) invisible wastage (cutting and burning losses) of maximum 0.5% will be admissible. 4.9.2 Owner reserves the right to take back such sections or quantity of steel issued in excess of quantity as per fabrication drawings plus permissible wastage where raw steel is issued free of cost by Owner. The contractor shall return to the Owner all such steel supplied in good and acceptable condition. In case of failure of the Contractor to return such surplus steel on demand by the Owner , Owner reserves the right to recover the cost of such steel at a penal rate of twice the SAIL- Stockyard rate of that particular section of steel as on the date of accountability. 4.9.3 If the Contractor fails to return scrap / wastage generated as per the percentage mentioned at 4.9.1. recovery on account of such scrap / wastage shall be made by the owner at prevailing rate of steel+ 20 pc per tonne. The charging of penal rate shall be without prejudice to any other remedies or action ,available to the Owner, against the Contractor. 4.10 4.10.1 Despatch Instructions Each despatchable structure shall bear mark no. along with reference drawing number at two prominent locations (e.g. on flange and bottom of base plate of a column). 4.10.2 "As built" drawing shall be prepared after fabrication is completed to indicate additions / alterations made during the process of fabrication. © 2007 MECON Limited All rights reserved Structural Page 41 of 83 GS-04 General Technical Specification 4.10.3 Control assembly of important structures shall be done in the shop floor before despatch to avoid mismatching. For all such important structures, match marking shall be given at the control assembly stage in the shop floor and such match markings shall be made clearly visible while assembling the structures at site. 4.10.4 Centre lines of column flanges and both sides of web shall be punched, preferably at top and bottom to facilitate alignment after erection. ERECTION OF STEEL STRUCTURES 5. 5.1 Scope The scope of work under erection includes in addition to provision of erection and transport equipments, tools and tackles, consumables, materials, labour and supervision, the following: a) Storing and stacking at site of erection of all fabricated structural components/ units/assemblies till the time of erection. b) Transportation at site of structures. c) Receiving at site of structures including site handling /movement, unloading, storing and stacking at site of erection of technological structures such as bunkers and the related structures d) All minor rectification / modification such as : i) Removal of bends, kinks, twists, etc. for parts damaged during transportation and handling; ii) Cutting chipping, filing, grinding, etc., if required, for preparation and finishing of site connections; © 2007 MECON Limited All rights reserved Structural Page 42 of 83 GS-04 General Technical Specification iii) iv) e) Reaming for use of next higher size bolt for holes which do not register or which are damaged. Welding of connections in place of bolting for which holes are either not drilled at all or wrongly drilled during fabrication. Other rectification work such as i) ii) iii) iv) Re-fabrication of parts, damaged beyond repair during transportation and handling or incorrectly fabricated. Fabrication of parts omitted during fabrication by oversight or subsequently found necessary. Plug-welding and re-drilling of holes which do not register and which cannot be reamed for use of next higher size bolt. Drilling of holes which are either not drilled at all or are drilled at incorrect position during fabrication. f) Fabrication of minor items/missing items or such important items as directed by the Owner Consultant. g) Assembly at site of steel structural components wherever required including temporary supports and staging. h) Making arrangements for and providing all facilities for conducting ultrasonic X-ray or gamma ray tests on welds; getting the tests conducted by reputed testing laboratories, making available test films/ graphs, reports and interpretation. i) Rectifying at site, damaged portions of shop primer by cleaning and touch-up paint. j) Erection of structures including making connections by bolts/high strength friction grip bolts / welding. k) Alignment of all structures true to line, level plumb and dimensions within specified limits of tolerances as per IS :12843 “Tolerance for Erection of Steel Structures”. l) Application of second coat of primer paint and two coats of finishing paint at site after erection. m) Grouting of all column bases after proper alignment of columns and only after obtaining clearance from Owner / Consultant. n) Supply of labour in sufficient numbers, directed by the Owner / Consultant. o) Conducting preliminary tests. © 2007 MECON Limited All rights reserved acceptance Structural Page 43 of 83 where necessary, and as final acceptance GS-04 General Technical Specification p) Preparation of as built drawings, preparing of sketches/drawings to suit field engineering decisions, availability of material, convenience of fabrication, transportation and erection and changes during fabrication and erection. All such works are subject to approval by the Owner / Consultant. 5.2 Erection Drawings 5.2.1 The erection drawings prepared by the Contractor and any approved arrangement drawings, specifications or instructions accompanying them shall be followed in erection of structures and miscellaneous connected items throughout the project. 5.3 Storing and Handling 5.5.1 The fabricated materials on receipt at site shall be carefully unloaded, examined for defects, checked , stored out for each building and stacked securely on skids above level ground which shall be kept clean and properly drained. Girders and beams shall be placed upright and stored. Long members, such as columns and chord members, shall be supported on skids spaced near enough to prevent damage from deflection. 5.5.2 The fabricated materials shall be verified with respect to markings on the marking plan or shipping list which shall be supplied by the Contractor. 5.5.3 Any material found damaged or defective shall be stacked separately and the damaged or defective portions shall be painted in distinct colour for identification. Such materials shall be dealt with as ordered by the Owner / Consultant. 5.5.4 The handling and storing of the component parts of a structure shall involve the use of methods and appliances not likely to produce injury by twisting, bending or otherwise deforming the structures. No member slightly bent or twisted shall be put in place until the defects are corrected. Members seriously damaged in handling shall be rejected. 5.4 Defects in material & fabrication © 2007 MECON Limited All rights reserved Structural Page 44 of 83 GS-04 General Technical Specification 5.4.1 All materials shall be straight unless required to be of curvilinear form and shall be free from twist. All cold straightening shall be done by pressure only. 5.4.2 During assembly and during erection of the units to position, the Contractor shall compare the structures with the drawings to ensure that there are no fabrication omissions or errors. Should any omission or defect be found the same shall be brought to the notice of the Owner / Consultant who will issue necessary instructions for the rectification. 5.5 Setting out 5.5.1 The Contractor shall prepare geodetic survey scheme of all embedded parts and holding down bolts and submit the same to Owner / Consultant. The Contractor shall inform the Owner / Consultant about any discrepancy with approved design drawings well in advance of erection and if necessary shall make necessary adjustments at site or during fabrication of structures. 5.5.2 The Contractor shall assume, full responsibility for the free and correct setting out of all steel work and erection correctly in accordance with position, alignment, dimensions and levels shown on the approved drawings and plumbing vertical members. Particular care shall be taken to ensure free expansion and contraction wherever provided. Notwithstanding any assistance rendered to the Contractor by the Owner / Consultant, if at any time during the progress of the work, any error should appear or arise therein, on being required to do so, the Contractor at his own cost shall remove and amend the work to the satisfaction of the Owner / Consultant. 5.6 Assembly and Erection 5.6.1 Before starting erection, the Contractor shall submit to the Owner / Consultant for his approval the method he proposes to follow and the number of types of equipments and temporary, works he proposes to use for the erection. 5.6.2 The approval of drawings by the Owner / Consultant will not relieve the Contractor from the basic approach to design as regards the loads which the erection equipment and temporary work shall be called upon to .carry and support. Adequate allowance and provision shall be made for lateral forces and wind loads. © 2007 MECON Limited All rights reserved Structural Page 45 of 83 GS-04 General Technical Specification 5.6.3 If in the opinion of the Owner / Consultant, the tools, tackles plant and equipment instruments, apparatus, etc. arranged by the Contractor are not sufficient or are inadequate for the fulfilment of the contractual obligations of the Contractor within the stipulated period, the Owner / Consultant will have the right to order the Contractor and the Contractor shall comply with the order to bring/arrange such additional tools, tackles, plant and equipment instruments, apparatus, etc. to the site and employ the same to complete the work in time. All charges in connection thereof shall be borne by the Contractor. 5.6.4 Proper consideration shall be given to the following items during erection. i) ii) iii) iv) v) vi) vii) viii) ix) ii) iii) 5.6.5 Frame of building to be true and plumb. Temporary guying and bracing shall be used to align the framing during erection, if required. Temporary bracing may be required to sustain forces due to erection loads and equipments. Erected parts of the structures shall be made stable during all stages of erection. The stability of structures subjected to the action of wind, dead weight and erection forces shall be attained by observing specified sequence of erection of vertical and horizontal structural members and by installing permanent and temporary bracings. Erection members shall be held securely in place by bolts to take care of dead load, wind load and erection load. Free expansion and contraction wherever provided No final bolting or welding of joints shall be done until the structure has been properly aligned and consent obtained from Owner / Consultant. Erection tools and machinery shall be of suitable capacity for handling the materials furnished and must be in safe operating conditions at all times to avoid danger to materials and personnel. In positioning beams, columns or other steel members the use of steel sledges shall not be permitted. The Contractor shall report all failures of the fabricated Steel to fit together properly to the Owner / Consultant and shall obtain approval prior to taking corrective measures. Steel members shall not be allowed to fall or be subject to shock or impact due to other members being swung into position or for any other cause. All exposed bolt holes not required shall be plugged Erection shall be carried out according to the best modern practices and as laid down in the IS : 800-1984 and other relevant standards referred © 2007 MECON Limited All rights reserved Structural Page 46 of 83 GS-04 General Technical Specification to therein and according to this erection Specification together with approved erection drawings and Technical Specification. 5.6.6 The Contractor shall design, manufacture, erect and provide false work; staging, temporary supports, etc. required for safe and accurate erection of structural steelwork and shall be fully responsible for the adequacy of the same. 5.6.7 The Contractor shall, if so required by the Owner Consultant, get his drawings, erection schemes and designs for such false work, staging, etc. approved by the Owner / Consultant, but such approval by the Owner / Consultant shall not relieve the Contractor of any of his responsibilities for the safety of such works. As far as possible, assemblies of structures shall be made on the ground itself. 5.6.8 The Contractor shall provide adequate supervision at all stages of the work and examine each portion of the work for accuracy before commencing the erection of the next structural member. The Contractor shall also provide facilities such as adequate temporary access ladders, tools and tackles, instruments, etc. satisfactory to Owner Consultant for his inspection at any stage during erection. 5.6.9 Instrumental checking for correctness of initial setting out of structures, and adjustment of alignment shall be carried out in sequence at different stages as determined by design as against checking and adjustment of alignment in one stage after completion of entire erection. The final levelling and alignment shall be carried out immediately after completion of each section of a building or when called for by the Owner / Consultant. 5.6.10 All structural members shall be erected with erection marks in the same relative position as shown' in the appropriate erection and shop drawings. 5.7 Field connections 5.7.1 The holes of erection joints required to be machine bolted shall be filled with temporary bolts and plugs after mounting the structures. The number of bolts and plugs shall be determined by design but it shall not be less than 50% of the total number of holes. In joints where the number of holes is equal to 5 or less, not less than 3 holes shall be filled. The number of plugs shall be about 20% of the holes filled. © 2007 MECON Limited All rights reserved Structural Page 47 of 83 GS-04 General Technical Specification 5.7.2 The number of washers on permanent bolts shall not be more than two (and not less than one) for nut and one for the bolt head. Wooden rams or mallet shall be used in forcing members into position, in order to protect the metal from injury and shocks. Chipping of edges of plates shall be done without breaking parent metal. Chipped edges shall be finished with a file and all short corner and hammered rough faces shall be rounded off. Chipping with the use of sledge hammer shall only be permitted in exceptional cases and shall be done without resulting in fractured edges. 5.7.3 Where bolting is specified on the drawings, the bolts shall be tightened to the specified limit. The threaded portion of each bolt shall project through the nut by at least one thread. Tapered washers shall be provided for all heads and nuts having bearing on bevelled surfaces. Use of special bolts, such as high strength friction grip bolts, shall be according to the relevant Indian or other recognized standards and shall be subject to the prior approval of the Owner / Consultant before use. 5.7.4 Spring washers or lock nuts shall be provided as specified in the design/shop drawings. All machine fitted bolts shall be perfectly tight and the ends shall be checked to prevent nuts from becoming loose. No unfilled holes shall be left in any part of the structures. All field assembly and welding shall be executed in accordance with the requirements for shop fabrication. Where the steel has been delivered painted, the paint shall be removed before field welding, for a distance of at least 50mm on either side of the joints. 5.7.5 Erection bolts shall be retained in position permanently even after site welding 5.8 Assembly by high strength friction grip bolts 5.8.1 The mating surfaces shall be absolutely free from grease, lubricant, dust, rust, etc. and shall be thoroughly cleaned before assembly. The preparation of the mating surfaces shall be done as specified in the design drawings. 5.8.2 Nuts shall be tightened up to the specified torque with the help of torque wrench or by half turn method with the help of pneumatic wrench lever. Torque value has to be specified in design / fabrication drawings itself. The direction of tightening of the nuts shall be from the middle towards the periphery of the joint. The bolt head, nuts and edges of the mating surfaces shall be sealed with a coat of paint to obviate entry of © 2007 MECON Limited All rights reserved Structural Page 48 of 83 GS-04 General Technical Specification moisture. As far as possible, the diameter of bolts and nature of mating surface preparation shall be kept uniform to have specified unique torque. 5.9 Bedding and grouting 5.9.1 Base plates shall be set to elevations shown in the drawings, supported and aligned using steel wedges and shims or any other approved method. The supply of wedges, shims and any other material for alignment shall be the responsibility of the Contractor as part of his work. Plates shall be levelled, properly positioned and the anchor bolts properly tightened. The bedding/grouting shall not be carried out until a sufficient number of columns have been properly aligned, levelled and plumbed, and sufficient girders, beams, trusses and bracings are in position to the satisfaction of the Owner / Consultant. 5.9.2 Grouting shall be done before casting of elevated RCC floors , if any, and before equipments contributing to the loading on columns are placed in position. No moving equipment shall be tested and no trial run of any equipment conducted, before grouting has been done and cured to the satisfaction of the Owner / Consultant. 5.9.3 Grouting shall be minimum M25 grade or one grade higher than the grade of base concrete with 10 mm and below graded coarse aggregate. Ready-mix, non-shrink, free-flow grout from recognised manufacturer as approved by the Owner / Consultant shall be used with pressure grouting technique to ensure proper filling-up of all void spaces underneath the base plate. Manufacturer’s recommendations / instructions shall be followed for proper application of grout material. 5.9.4 5.10 The Contractor shall inform the Owner / Consultant when the base plates are ready for grouting for their verification. The Contractor shall be responsible for final vertical and horizontal alignment of all the base plates. Painting after erection The painting shall be as per painting specifications and instructions given in TS and , in GS for painting works. 5.11 ACCEPTANCE OF WORK © 2007 MECON Limited All rights reserved Structural Page 49 of 83 GS-04 General Technical Specification 5.11.1 Acceptance of erected steel structures shall completion of erection of the whole building or in blocks. be either after Intermediate acceptance certificates will be given in the following cases i) ii) Any steelwork or part thereof, embedded in concrete. Steel structures which are to be covered in the process of carrying out further work. 5.11.2 The following documents shall be prepared and produced by the Contractor at the time of acceptance of erected steel structures :i) ii) iii) iv) v) 6.0 Documents showing approved deviations made during execution of erection work. Documents showing acceptance of embedded structural steelwork. Certificates / documents on control checking and test of materials (if any) and welds. Data and results of Geodetic measurements while checking the erection of structures. Copies of "As Built Drawings" showing thereon all additions and alterations. WELDING SPECIFICATIONS 6.1 General 6.1.1 The welding and welded work shall conform to IS:816 and other relevant codes unless otherwise specified. Electrodes shall conform to IS:814 and shall be approved by the Owner / consultant. 6.1.2 Welding shall be done by Electrical Arc Process. Automatic welding shall be employed for important structures as specified in the drawings. Generally, submersed arc, Automatic & Semi-automatic welding shall be © 2007 MECON Limited All rights reserved Structural Page 50 of 83 GS-04 General Technical Specification employed. Only where it is not practicable, Manual Arc welding may be resorted to. In case of Manual Arc Welding, recommendations of electrode manufacturer are to be strictly followed. 6.1.3 Welding shall not be done under such weather conditions which might adversely affect the efficiency of the welding and where necessary, effective protection and other safeguards shall be provided. 6.1.4 Only qualified welders suitable for the job shall be employed. The Owner / Consultant at his discretion can order periodic tests in accordance with IS:817 of the welders and / or of the welds produced by them at no extra cost. Welding shall be done using requisite jigs and fixtures to avoid distortions or damage to members during / after welding. Welds on exposed work shall be finished uniformly smooth to present a neat appearance. 6.1.5 The layouts and sequence of operations shall be arranged so as to eliminate distortion and shrinkage stress to the satisfaction of the Inspector. Welding work shall be under constant supervision of competent welding supervisor and shall be done in a properly organized manner with the approved quality welding sets and with automatic welding machines. Detailed welding procedure shall be submitted to the Owner / Consultant and approval of the same shall be obtained before fabrication is commenced. 6.2 Welding Procedure 6.2.1 Welding procedure to be prepared by the Contractor shall include the following : i) ii) iii) iv) v) vi) vii) viii) ix) x) xi) xii) xiii) Type and size of electrodes. Current and arc voltage.(for automatic welding) Length of run per electrode, or (for automatic welding) speed of travel. Number and arrangement of runs in multi-run welds. Position of welding. Preparation and set-up of parts. Welding sequence. Pre or, post-heating. Specification and thickness of steel Welding process ( manual arc / submerged arc welding ) Thickness of components meeting at a joint Pre and post heating requirement Weather condition – restrictions thereof © 2007 MECON Limited All rights reserved Structural Page 51 of 83 GS-04 General Technical Specification xiv) xv) xvi) xvii) Use of jigs and fixtures Type of non-destructive testing to be carried out Inspection procedure to be followed Sequence and process to be followed in different multiple-pass butt welding for different plate thicknesses. . The welding procedure shall be subject to Owner’s / Consultant’s approval. 6.2.2 The welding procedure shall be arranged to suit the details of the joints as indicated in the drawings and the positions in which the welding is to be carried out. The welds shall meet the requirements of quality specified. 6.2.3 All electrodes for use in the work to which the specification relates shall be kept under dry conditions. Electrodes which are damaged by moisture shall not be used unless it is certified by the manufacturer that when it is properly dried there shall be no detrimental effect. Any electrode which has part of its flux coating broken away or is otherwise damaged shall be discarded. 6.2.4 Low hydrogen electrodes and flux for submerged arc welding shall be dried at 250- 300 deg. C for one hour in drying oven before use. 6.2.3 At site, the electrodes shall be kept in proper coves while using them for welding 6.2.4 All metal arc welding shall be as per IS : 9595 6.2.5 Submerged arc welding of mild steel and low alloy steel shall be as per IS : 4353 6.2.6 For multi-run weld deposit the succeeding run shall be done only after the preceding run is cleaned of all slag and flux deposits. 6.2.7 The Contractor shall prepare the edges with an automatically controlled flame cutting torch followed by grinding correctly to the shape, size and dimensions of the groove, prescribed in the design and shop drawings. in case of U-groove joint, the edges shall be prepared with an automatic flame cutting torch in two passes following a bevel cut with a gouging pass, or by machining. 6.2.8 The welding surfaces shall be smooth, uniform and free from fins, tears, notches or any other defect, which may adversely affect welding. © 2007 MECON Limited All rights reserved Structural Page 52 of 83 GS-04 General Technical Specification Welding surfaces or the surrounding surfaces within 50 mm of weld shall be free from loose scale, slag, rust, grease, paint, moisture or any other foreign material. Pre-bending of plates for three plate welded sections shall be done where found necessary. 6.2.9 Manipulators may be used where necessary and shall be designed to facilitate welding and to ensure that all welds are easily accessible to the operators. Where full strength butt welds are specified run-on and run-off pieces shall be used. The welding shall be such that the face of weld deposit shall at all places be proud of the surfaces of the parent metal by 1 to 1.5 mm. Where a flush surface is required, the surplus weld metal shall be ground and dressed off. 6.2.10 After completing each run of weld, all slag shall be thoroughly removed, and the surface cleaned before starting the next run of weld. The weld metal, as deposited (including tack welds if to be incorporated) shall be free from cracks, slag, inclusions, gross porosity, cavities and other deposition faults. The weld metal shall be properly fused with the parent metal without serious undercutting or overlapping at the toes of the weld. The surfaces of the weld shall have a uniform and consistent contour and uniform appearance. 6.2.11 All weld runs found defective shall be cut by using either chipping hammer, gouging torch, or suitable grinding wheel in such a manner that adjacent material is not injured in any way. Peeling of the welds involving deformation of the weld surface either during de- slagging or thereafter shall not be allowed. 6.2.12 Arc-strikes on parent surfaces of structures shall be strictly avoided. 6.3 Control in Welding 6.3.1 The extent of quality control in respect of welds for structural elements for both statically and dynamically loaded structures shall be as follows and shall be conducted by the contractor at his own cost:a) Visual Examination - All welds shall be 100% visually inspected to check the following: i) © 2007 MECON Limited All rights reserved Presence of undercuts Structural Page 53 of 83 GS-04 General Technical Specification ii) iii) iv) v) vi) Visually identifiable surface cracks in both welds and base metals. Unfilled craters Improper weld profile and size Excessive reinforcement in weld Surface porosity Before inspection, the surface of weld metal shall be cleaned of all slag, spatter beads, scales etc. by using wire brush or chisel. b) Dye Penetration Test (DPT) - This shall be carried out for all important fillet welds and groove welds for both statically and dynamically loaded structures to check the following i) ii) Surface cracks Surface porosities Dye Penetration Test shall be carried out in accordance with American National Standard ASTME 166. c) Ultrasonic- testing: Ultrasonic test shall be conducted for all groove welds and heat affected zone in dynamically loaded structures and for other important load bearing butt welds in statically loaded structures as desired by Owner, to detect the following i) ii) iii) iv) Cracks Lack of fusion Slag inclusions Gas porosity Ultrasonic testing shall be carried out in accordance with American National Standard ANSI/AWS DI.1-96. Before ultrasonic test is carried out, any surface irregularity like undercuts, sharp ridges etc. shall be rectified. Material surface to be used for scanning by probes must allow free movement of probes. For this purpose, surface shall be prepared to make it suitable for carrying out ultrasonic examination. d) Radiographic Testing (X-ray and & Gamma-Ray Examination) This test shall be limited to 2% of length of welds for welds made by manual or semi- automatic welding and 1% of length of weld if made by automatic welding machines. The location and extent of © 2007 MECON Limited All rights reserved Structural Page 54 of 83 GS-04 General Technical Specification weld to be tested by this method will be decided by Owner to detect the following defects : i) ii) iii) iv) v) gas porosity slag inclusions lack of penetration lack of fusion cracks Radiographic testing shall be conducted in accordance with American National Standard ANSI/AWSDI.1-96. Any surface irregularity like undercuts, craters pits etc. shall be removed before conducting radiographic test. The length of weld to be tested shall not be more than 0.75 x focal distance. The width of the radiographic film shall be width of the welded joint plus 20 mm on either side of the weld. 6.3.2 6.4 The Contractor shall provide testing equipment for conducting nondestructive tests for confirming the integrity of welding wherever necessary as directed by the Owner / consultant. Acceptable Limits of Defects of Weld Limits of Acceptability of welding defects shall be as follows: a) Visual inspection & Dye Penetration Test The limits of acceptability of defects detected during visual inspection and Dye Penetration Test shall be in accordance with American National Standard ANSI/AWS D1.1-96. b) Ultrasonic Testing - The limits of acceptability of defects detected during ultrasonic testing shall be in accordance with American National Standard ANSI/AWS D1.1-96. c) Radiographic testing - The limits of acceptability of defects detected during Radiographic testing shall be in accordance with American National Standard ANSI/AWS D1.1-96 General guidelines for permissible deviations in welding have been given in Section 11.0 of this document. © 2007 MECON Limited All rights reserved Structural Page 55 of 83 GS-04 General Technical Specification 6.5 Rectification of Defects in Welds In case of detection of defects in welds, the rectification of the same shall be done as follows i) ii) iii) 7.0 All craters in the weld and breaks in the weld run shall be thoroughly filled with weld. Undercuts, beyond acceptable limits, shall be repaired with dressing so as to provide smooth transition of weld to parent metal. Welds with cracks and also welds with incomplete penetration, porosity, slag inclusion etc. exceeding permissible limits shall be rectified by removing the length of weld at the location of such defects plus 10 mm from both ends of defective weld, and shall be re-welded. Defective weld shall be removed by chipping hammer gouging torch or grinding wheel. Care shall be taken not to damage the adjacent material. PAINTING OF BUILDING STEEL STRUCTURES All steel structural work shall be painted as follows unless otherwise stated in the drawing / Technical Specification. Relevant section of the GS shall be referred for further guidelines on painting. 7.1 Surface Preparation The steel surface which is to be painted wall be cleaned of dirt and grease, and the heavier layers of rust shall be removed by chipping prior to actual surface preparation to a specified grade. Following are the type and standards of surface preparation to be followed based on the requirement of a particular painting system or as specified in the design drawings. Manual / Power tool cleaning Manual/Power tool cleaning shall be done as per Grade St-2 or St-3 of Swedish Standard institution SIS 05 5900 or cl. 7.2.1.1 & 7.2.1.2 of IS : 1477 (Part - I). © 2007 MECON Limited All rights reserved Structural Page 56 of 83 GS-04 General Technical Specification Grade St-2 :- Thorough scraping and wire brushing, machine brushing, grinding , etc - This grade of preparation shall remove loose mill scale, rust and foreign matter. Finally the surface is to be cleaned with a vacuum cleaner or with clean compressed air or clean brush. After preparation, the surface should have a faint metallic sheen. The appearance shall correspond to the prints designated St-2. Grade St-3 :- Very thorough scraping and wire brushing, machine brushing, grinding etc. The surface preparation is same as for St-2 but to be done much more thoroughly. After preparing the surface, it should have a pronounced metallic sheen and correspond to the prints designated St-3. BLAST CLEANING – Blast cleaning shall be done by shot blasting as per Grade SA-2 or SA- 2 !/2 as specified in the drawings. If no grade of surface preparation is specified, St-2 grade of preparation as per Swedish Standard shall be followed. 7.2 Paints and painting Guidelines stipulated here shall be considered along with those specified in GS separately for painting. 7.2.1 Manufacture of paints, mixing of paints, etc - shall be generally according to the relevant IS codes of practice and as per guidelines in the General Specification in the relevant chapter. 7.2.2 In the event of conflict between this General Specification for painting and the paint manufacturer's specification, this conflict shall be immediately brought to the notice of the Owner / Consultant. Generally in cases of such conflicts, manufacturer's Specification/recommendation shall prevail. 7.2.3 Generally compatibility between primer intermediate and finishing paint shall be certified by the paint manufacturer supplying the paints. Before the Contractor buys the paint in bulk, it is recommended to obtain sample of paint and establish “Control Areas of Painting". On Control Area, surface preparation and painting shall be carried out in the presence of the manufacturer of paint. 7.2.4 Control areas shall serve as specimen of painted surfaces, for observing and recording quality and performance of paint. © 2007 MECON Limited All rights reserved Structural Page 57 of 83 GS-04 General Technical Specification 7.2.5 In case of any doubts, the Contractor shall send samples of paint to recognized testing laboratories to establish quality of paint with respect to: i) Viscosity ii) Adhesion/bond of paint to steel surfaces iii) Adhesion/simulated salt spray test iv) Chemical analysis/percentage of solid by weight v) Normal wear resistance as encountered during handling and erection vi) Resistance against exposure to acid fumes, and such other tests as considered necessary by the Owner / Consultant. Whole system of paint shall be obtained from the same manufacturer. 7.2.6 Guarantee period on paints and painting shall commence from the date of completion of finishing coat of paint on entire structures. The guarantee period shall be indicated depending on the type of surface preparation and system of painting. To fulfil this obligations, the Contractor may obtain from the painting manufacturer, guarantee for the performance of paint/painted surfaces. 7.2.7 The painting material as delivered to the Contractor/Applier, must be in the manufacturer's original containers bearing thereon manufacturer's name, brand and description. Paint/painting material in the containers without labels or with illegible labels shall be rejected, removed from the area and shall not be used. Thinners wherever used shall be those recommended by the paint manufacturer and shall be obtained in the containers with manufacturer's name and brand name of the thinner legibly printed, failing which the thinner is liable to be rejected and shall not be used. 7.2.8 Wherever shop primer painting is scratched, abraded or damaged, the surface shall be thoroughly cleaned using emery paper and power driven wire brush wherever warranted or as directed by the Owner / Consultant, and touched up with corresponding primer. Touching up paint shall be matched and blended to conspicuous marks. If more than 50% of the painting surface of an item requires repair, the entire item shall be mechanically cleaned and new primer coats followed by finishing coats shall be applied as per painting Specification. 7.2.9 All field welded areas on shop painted items shall be mechanically cleaned including the weld area proper, adjacent areas contaminated by © 2007 MECON Limited All rights reserved Structural Page 58 of 83 GS-04 General Technical Specification weld splatter or fumes & areas where existing primer / intermediate / finish paint is burnt. Subsequently, new primer and finishing coats of paint shall be applied as per painting Specification. 7.2.10 Application of paint shall be by spraying or brushing as per IS : 486 and IS . 487 and in uniform layers of 50% overlapping strokes by skilled painters Painting shall not be done when the temperature is less than 5 degree C or more than 45 degree C and relative humidity is more than 85%; unless manufacturer's recommendations permit. Also painting shall not be done in foggy weather. During application, paint agitation must be provided where such agitation is recommended by the manufacturer. 7.2.11 Paint shall be applied at painting manufacturer's recommended rates. The number of coats shall be such that minimum dry film thickness specified is achieved. The dry film thickness (DFT) of painted surfaces shall be checked with ELCOMETER or measuring gauges to ensure specified DFT. 7.2.12 The inside surfaces of gutter which come in contact with rain water shall be provided with 2 finishing coats of water resistant, bitumastic paint of minimum DFT 75 microns, in addition to the primer coats of red oxide zinc phosphate in phenolic alkyde medium or 2 primer coats of epoxy based red oxide zinc chromate/epoxy based zinc phosphate of minimum DFT 25 microns per coat, as given in Specification and drawings. Other structures shall be painted as per painting system mentioned . 7.2.13 All structures shall receive one coat of primer paint at shop after fabrication before despatch after surface preparation has been done as per requirements. Unless otherwise specified all structures after erection shall be given one coat of primer and two coats of finishing paint of approved colour and quality. The under coat shall have different tint to distinguish the same from the finishing coat. Edges, corners, crevices, depressions, joints and welds shall receive special attention to ensure that they receive painting coats of required thickness. 7.2.14 Machine-finished surface shall be coated with white lead and tallow before shipment or before being put out into the open air. Part of steel structures to be embedded in concrete, shall be given a protective coat of Portland cement slurry immediately after fabrication after this part is thoroughly cleaned from grease, rust, mill scales etc. No paint shall be applied on such parts. © 2007 MECON Limited All rights reserved Structural Page 59 of 83 GS-04 General Technical Specification 7.2.15 Zinc-rich primer paints, which have been exposed several months before finishing coat is applied, shall be washed down thoroughly to remove soluble zinc salt deposits. In similar circumstances, the surface of paint based on epoxy resin should be abraded or lightly blast cleaned to ensure adhesion of next coat. 7.2.16 Paints selection shall be based on Preferred make list of BSP. Type of paint ( heat resistant/high corrosion resistant) required to be applied for a structure shall be approved by BSP and prior permission shall be taken before application of paint. 8.0 GENERAL REQUIREMENTS 8.1 Programme The Contractor shall prepare a programme showing the date of supply of steel to his work, and the fabrication and erection of each section of the structure or structures. The erection dates shall be the dates for completion of all the follow-up work in addition to main erection keeping overall completion of project in view. The programme shall include quantum of different activities of work planned month wise to complete the work. 8.2 Drawings 8.2.1 The Contractor shall prepare steel structural arrangement drawings and design drawings along with analysis and design calculation of major elements and take their approval by Owner / Consultant within the time schedule as per contract. Necessary number of prints of drawings and documents; as per contract shall be submitted for approval. The Contractor shall prepare the fabrication drawings and bill of materials shall form part of the fabrication drawings which will be included in the body of the drawing or prepared separately. © 2007 MECON Limited All rights reserved Structural Page 60 of 83 GS-04 General Technical Specification 8.2.2 Even if the drawings are Approved / Commented by the Owner / Consultant, the Contractor shall not be relieved of the responsibilities for the accuracy of the detailed dimensions shown in the drawings and the safety of all structural connections. 8.2.3 Notes on specifications shown on design drawings shall considered as superseding or overriding the specifications with which they conflict. On all drawings, dimensions shown in figures shall be acted on. Erection drawings in requisite number of sets shall be submitted to the Owner / Consultant showing thereon all authorized additions and alterations in the process of erection. These drawings shall show the "As-Built Installations". 8.2.4 Supply and distribution of fabrication drawings. and other documents like bolt list etc. for the contractors own use or for the use of his subcontractors shall be the responsibility of the Contractor. 8.2.5 The Contractor shall assume full responsibility for the correct setting out of all steel works and erecting correctly in accordance with alignment and levels shown on the approved drawings and plumbing of vertical members. Notwithstanding any assistance rendered to the Contractor by the Owner / Consultant, if at any time during the progress of the work, any error should appear or arise therein, on being required to do so, the Contractor at his own cost shall remove and amend the work to the satisfaction of the Owner/Consultant. 8.2.6 The Contractor shall provide his own measuring instruments for setting out, levelling and aligning work at his own expense. 8.3 Co-ordination with other Contractors The structures shall have to be erected suitably detailed with erection of equipment or construction of civil works. The Contractor shall ensure spirit of co- operation with other contractors and strict adherence to the schedule so that erection schedules of the other parties are not affected. 8.4 Staging Any staging necessary for the pre assembly work of structures shall be provided by the Contractor. © 2007 MECON Limited All rights reserved Structural Page 61 of 83 GS-04 General Technical Specification 8.5 Rules and regulations of safety, electricity boards, factory etc. The Contractor shall at all times comply with such rules and regulations as stipulated in relevant factory acts, electricity rules, safety regulations, etc. 8.6 Deviations Should the contractor wish to deviate from any specifications or approved drawings and /or technical specifications ,he shall obtain the Owner/Consultant’s written authority before proceeding with the deviations. 9. 9.2 9.3 INSPECTION OF STRUCTURES The Owner / Owner’s Inspector shall have free access at all times to those parts of Contractor's or his Sub- Contractor's works which are concerned with the fabrication of steel works and shall be afforded all reasonable facilities at all stages of preparation, fabrication and trial assemblies for satisfying himself that the fabrication is being undertaken in accordance with the provisions of relevant specification. All gauges and templates, tools, apparatus, labour and assistance for checking shall be supplied by the contractor free of charge. The Owner / Inspector may at his discretion, check the test results obtained at the Contractor's works, by independent test at the Government Test House or elsewhere, and should the material so tested be found to be unsatisfactory, the cost of such test shall be borne by the Contractor. Contractor shall make all necessary arrangements for stage inspection by Owner/Inspector during the fabrication at shop and incorporate all on-the-spot instructions / changes conveyed in writing to the Contractor. © 2007 MECON Limited All rights reserved Structural Page 62 of 83 GS-04 General Technical Specification 9.4 Material improperly detailed or wrongly fabricated shall be reported to the Owner/Inspector and shall be made good as directed. Minor misfits which can be remedied by moderate use of drift pins, and moderate amount of reaming and slight chipping may be corrected in that manner, if in the opinion of the Owner / Inspector the strength or appearance of the structure shall not be adversely affected. In the event the Owner / Inspector directs otherwise, the items shall be rejected and a completely new piece shall be fabricated. The cost of correcting errors shall be to the account of the Contractor. 9.5 The Owner / Owner’s Inspector shall have the power : a) To declare, before any structure is submitted for inspection, that the same is not in accordance with the contract, owing to the adoption of any unsatisfactory method of fabrication and the same will be rejected. b) To reject any structure as not being in accordance with specifications & drawings. c) To insist that no structure or parts of the structure once rejected is resubmitted for inspection/test, except in cases where the Owner / Inspector authorised representative considers the defects as rectifiable. 9.5.1 If, on rejection of structure by the Owner/Inspector the Contractor fails to make satisfactory progress within the stipulated period, the Owner / Inspector shall be at liberty to cancel the contract and fabricate or authorise the fabrication of the structures at any other place he chooses, at the risk and cost of the Contractor, without prejudice to any action being taken in addition to terms of General Conditions of Contract. 9.5.2 The Owner / Inspector's decision regarding rejection shall be final and binding on the Contractor. 9.5.3 The specifications prescribe various tests at specified intervals for ascertaining the quality of the work done. If the tests prove unsatisfactory, Owner/Inspector shall have liberty to order the Contractor to re-do the work, done in that period and/ or to order such alterations and strengthening that may be necessary at the cost of the Contractor and the contractor shall be bound to carryout such orders failing which the rectification/redoing shall be done by the Owner through other agencies and the cost recovered from the Contractor. © 2007 MECON Limited All rights reserved Structural Page 63 of 83 GS-04 General Technical Specification 9.5.4 Notwithstanding any inspection at the workshop the Owner/Inspector shall have the liberty to reject, without being liable for compensation any fabricated members or materials brought to site that do not conform to specifications / drawings. 9.5.5 All rejected materials shall be removed from the site of fabrication by the Contractor at his own cost and within the time stipulated by the Owner/Inspector. 10.0 10.1 QUALITY SYSTEM AND THIRD PARTY INSPECTION. GENERAL Inspection shall be carried out at the works of the Contractor during fabrication and on final product to ensure conformity of the same with the acceptable criteria of technical specifications, approved fabrication drawings and indicated standards. 10.1.1 This specification is in addition to the provisions laid down in Owner's General Condition of Contract (GCC) and special instructions to Contractor, if any. 10.2 QUALITY SYSTEM REQUIREMENTS. The Contractor must recognise the importance of quality and follow the defined quality programme in all manufacturing and quality control activities of the product. The Contractor shall define and implement the tasks and controls that shall provide needed assurance in case manufacturing of product is sub-contracted either partly or fully and / or for the procured components of the product. All bought-out components, if any, shall be procured from approved list of vendors issued by the Project Authority. Owner reserves the right to verify the quality programme and entire product characteristics to assure the intended and specified quality of the product. 10.3 QUALITY ASSURANCE PLAN (QAP) © 2007 MECON Limited All rights reserved Structural Page 64 of 83 GS-04 General Technical Specification 10.3.1 The Contractor shall furnish the Quality Assurance Plan (QAP) for the respective structural unit / component after finalisation of billing schedule for Owner's approval at least two months prior to start of manufacturing. 10.3.2 The Contractor shall indicate the procurement source and furnish to Owner during discussions on QAP, copies of Owner Order, Sub-Owner Order, and data sheets as backup reference materials for scrutiny & finalisation of QAP. 10.3.3 QAP shall be prepared & furnished by the Contractor in the prescribed format (enclosed as Annexure- B) for structural components, in four sets. 10.3.4 Inspection and test requirements shall be decided with due consideration of factors like safety, duty cycle, operating conditions, equipment life, environmental conditions, place of installation and statutory regulations, as applicable, for a particular component. Any, additional type or special test or routine tests if found necessary to establish the intended quality, shall be incorporated in the QAP on mutual agreement without any commercial implication. 10.3.5 Detailed QAP shall be prepared by the Contractor based on the general plan given by Owner and shall be approved by Owner to avoid any complication later. 10.3.6 QAP shall clearly indicate the followings through use of codes in the appropriate columns: a) Range of inspection & tests to be done by the Contractor during fabrication of structures from raw materials to finishing stage. b) Suggestive check / hold points for Owner's inspection and witnessing of tests during the fabrication and final product inspection. c) Details of test certificates, internal inspection reports and calibration certificates to be furnished by the Contractor to Owner. d) Inspection documents to be furnished by the Contractor to Owner for reference during inspection. 10.3.7 Sampling method for lot inspection of similar bulk items, if any, shall be indicated under column 16 of QAP with linkage to applicable standard. 10.3.8 While submitting the QAP, the Contractor shall indicate the acceptance criteria under column 15 of QAP form regarding check parameters of each © 2007 MECON Limited All rights reserved Structural Page 65 of 83 GS-04 General Technical Specification component. Acceptance criteria shall have reference of documents viz. Owner Order, Sub-Owner Order, T.S., Approved fabrication drawings. Wherever the acceptance criterion is not available in above documents, the same shall be specified with traceability to national / international specifications. 10.4 INDICATIVE SURVEILLANCE BY OWNER. 10.4.1 Surveillance level of Owner may vary from component to component as per product characteristics. Indicative extent of inspection for buildings and structures is furnished below for guidance of Contractors in developing QAP. Categories of Equipment ------------------------------i) Manufactured items (Structural fabricated and welded) Extent of Inspection. -----------------------Material & manufacturer’s test certificate to be submitted by giving inspection call for the main equipment in the final stage. Scrutiny of welding procedure and welder's qualification record shall be carried out if required as per governing code. Following checks / tests shall be carried out in the final stage: Visual inspection - Alignment and fitment checking - Dimensional checking Weld inspection - visual and NDT as per design requirements. Radiographs are to be shown and reports to be submitted to Owner for review during inspection, if applicable. 10.5 CALIBRATION OF MEASURING EQUIPMENT. 10.5.1 All the measuring equipment used for inspection & testing shall be calibrated and appropriate accuracy class of measuring equipment shall be used. Calibration standards used for calibration of measuring © 2007 MECON Limited All rights reserved Structural Page 66 of 83 GS-04 General Technical Specification equipment shall be traceable to national standards of National Physical Laboratory (NPL), New Delhi with unbroken chains of comparison. 10.5.2 Calibration Certificate of All Measuring Equipments. Valid calibration certificates for all measuring equipments used during inspection and testing with traceability to national standards of NPL / NPL accredited laboratories shall be furnished along with inspection call prior to undertaking inspection by Owner. Calibration certificates shall also indicate reference number of calibration standards calibrated by NPL / NPL accredited laboratories and copies of such calibration certificates of calibration standards shall also be furnished when asked for. 10.6 TEST CERTIFICATES AND DOCUMENTS. 10.6.1 For each of the items being fabricated, the following test certificates and documents, as applicable, in requisite copies including original shall be submitted to Inspection Agency. All test certificates must be endorsed by the Contractor with linkage to project, purchase order and acceptance criteria. i) Raw materials identification & physical and chemical test certificates for all materials used in fabrication of the component (except IS 2062-1992). ii) WPS, PQR & WPQ Documents as per applicable code. iii) Details of stage-wise inspection & rectification records for fabricated items and machined articles. iv) Control dimension chart with records of alignment, trueness of shape, etc. v) Details of heat-treatment and stress relieving charts as per specification. vi) Non-Destructive Test reports as per respective code. vii) Hardness test certificate. viii) Performance Test Certificates for all characteristics. © 2007 MECON Limited All rights reserved Structural Page 67 of 83 GS-04 General Technical Specification ix) Geometric accuracy and repeatability test reports of machine tools. x) Surface preparation and painting certificates. xi) Certificates from competent authority for the items coming under statutory regulations. 10.6.2 The Inspection Agency shall have the right to be present and witness all tests being carried out by the Contractor at their own laboratory or approved laboratories. Also, the Inspection Agency shall reserve the right to call for confirmatory test on samples, at his discretion. 10.7 MANUFACTURING AND INSPECTION SCHEDULE The Contractor shall submit the schedule for fabrication and inspection indicating components/ assembly / sub-assembly, date of approval of drawings / data sheets, address of Fabricator with contact person and scheduled date of inspection. Such reports shall be submitted to Owner with a copy to Inspection Coordinating Office once in a month. These monthly reports shall state the planning for next three months. Submission of first report must commence one month prior to commencement of fabrication activities of the component. 10.8 INTERNAL INSPECTION BY CONTRACTOR 10.8.1 The Contractor in accordance with approved drawings, T.S., Owner Order, and approved QAP shall carry out inspection and tests. The Contractor shall maintain records of each inspection and test carried out and signed documents shall be submitted to Owner for verification. 10.8.2 The Contractor shall carry out their internal inspection & obtain clearance from statutory bodies e.g. IBR, CCE, TAC, Weights & Measures, safety, IE rules etc. as and where applicable, prior to offering any component for Owner's inspection in accordance with approved QAP. 10.8.3 The Contractor shall ensure use of appropriate calibrated measuring equipment during their internal inspection, as well as, make available the same during Owner's inspection and tests. Also, they shall make necessary arrangement for access and use of Owner owned measuring equipment during inspection. 10.8.4 The Contractor shall identify all the inspected component / raw materials & shall maintain the record of status of inspection viz. inspected & found acceptable, require rectification / rework, rejected etc. © 2007 MECON Limited All rights reserved Structural Page 68 of 83 GS-04 General Technical Specification 10.8.5 The Contractor shall establish and maintain procedures to ensure that product that does not conform to specified requirements, is prevented from inadvertent use or installation. The description of non-conformity that has been accepted subsequently by Owner by concession and / or of repairs shall be recorded. Repaired and reworked product shall be offered for re-inspection to Owner along with records of corrective action taken. 10.8.6 The Contractor shall not despatch any equipment till receipt of despatch clearance from Owner. 10.9 METHOD OF UNDERTAKING INSPECTION & TESTING BY OWNER. 10.9.1 Agency Responsible:Inspection / Waiver of component shall be undertaken by various MECON Offices depending upon the location of manufacturers. 10.9.2 Method of Issuing Inspection Call to MECON: (i) Inspection call shall be given only on readiness of the assembly / sub-assembly and approval of all relevant drawings and QAP. In case assembly sub - assembly offered for inspection are found not ready, all the cost of visit of Owner's personnel shall have to be borne by the Contractor. Also, if the assembly / sub-assembly after inspection found not acceptable, require rework and involve Owner's re-inspection, all the cost of such re-inspections shall also be borne by the Contractor. (ii) Inspection call shall be floated to Owner with ten days clear margin, enclosing all documents like test Certificates, Internal Inspection Reports, Purchase Order, Sub-Purchase Order, T.S., Approved QAP, approved GA drawings/ data sheets and fabrication drawings with a copy of call letter to Inspection Co-ordinating Office. Inspection calls without above documents shall be ignored. (iii) The supplier shall offer substantial quantities for economical inspection consistent with the size of order. 10.10 OBLIGATIONS OF CONTRACTOR. © 2007 MECON Limited All rights reserved Structural Page 69 of 83 GS-04 General Technical Specification 10.10.1 The Contractor shall provide all facilities and ensure full and free access of the Inspection Engineer of Owner to the Contractor's or their Sub-Contractor's premises at any time during contract period, to facilitate him to carry out inspection & testing of the product during or after manufacture of the same. 10.10.2 The Contractor shall delegate a Representative / Co-ordinate to deal with Owner / Consultant on all inspection matters. Also, Contractor's Representative shall be present during all inspection at Sub-Contractor's works. 10.10.3 The Contractor shall comply with instructions of the Inspection Engineer fully and with promptitude. 10.10.4 The Contractor / Sub-Contractor shall provide all instruments, tools, necessary testing & other inspection facilities to Inspection Engineer free of cost for carrying out inspection. 10.10.5 The cost of testing welds by ultrasonic, radiographic and dye penetration tests etc. in the fabrication workshop shall be borne by the Contractor. 10.10.6 The Contractor shall ensure that the assembly / component of the plant and equipment required to be inspected, are not dismantled or despatched before inspection. 10.10.7 The Contractor shall not offer equipment for inspection in painted condition unless otherwise agreed in writing by Owner / Consultant. 10.10.8 The Contractor shall ensure that the equipment and materials once rejected by the Inspection Engineer are not re-used in the manufacture of the plant and equipment. Where parts rejected by the Inspection Engineer have been rectified, as per agreed procedures laid down in advance, such parts shall be segregated for separate inspection and approval, before being used in the work. 10.11 STAMPING AND ISSUE OF INSPECTION DOCUMENTS. Inspection Memo: For stage inspection & for rejected items / items which do not conform to Technical Specification in one or more quality characteristics requiring rectification / rework, Inspection Memo shall be issued in © 2007 MECON Limited All rights reserved Structural Page 70 of 83 GS-04 General Technical Specification standard form indicating therein the details of observation & remarks. Fabricator shall indicate all the non-conformities with respect to specification of the product in the Inspection Memo for further control. Inspection Certificate: On satisfactory completion of final inspection & testing by Owner / Third Party Inspector, all accepted plant & equipment shall be stamped suitably and the Inspection Engineer for the accepted items shall issue Inspection Certificate in standard form. Inspection Waiver Certificate: For the waiver category of items identified in the approved QAP, Owner shall issue Inspection Waiver Certificate after scrutiny of Contractor's Internal Inspection Report, Test Certificates and other Documents as identified in QAP. 10.12. GENERAL CLAUSES 10.12.1 Inspection & tests carried out by Owner / Third Party Inspector shall not absolve the responsibility of the Contractor to provide acceptable product nor shall it preclude subsequent rejection. 10.12.2 Owner / Third Party Inspector reserves the right to inspect any product at any stage of manufacturing without prior notice to Contractor beyond pre-identified stages & hold points of approved QAP. 11. PERMISSIBLE DEVIATION IN ASSEMBLY OF WELDED JOINTS A) SQUARE BUTT-JOINT a) Gap between the ends of plates b) Stepping of one plate over the other : + 1.0 mm : + 1.0 mm B) SINGLE VEE-GROOVE JOINT a) Bevel angle © 2007 MECON Limited All rights reserved : + 5 deg Structural Page 71 of 83 GS-04 General Technical Specification b) Gap between two plates c) Stepping of one plate over the other d) Root thickness : + 1.0 mm : + 2.0 mm : + 1.0 mm C) LAP JOINT a) Over lap b) Gap between the surfaces : + 5.0 mm : + 1.0 mm D) TEE FILLET JOINT a) Gap between the edge of the web and the surface of the flange : + 2.0 mm E) DOUBLE VEE-GROOVE JOINT a) b) c) d) 12. Stepping of plate over one another Deviation in value of root thickness Deviation in bevel angle Deviation in value of gap : + 2.0 mm : + 1.0 mm : + 1.0 mm : + 1.0 mm PERMISSIBLE DEVIATIONS IN FABRICATION & ERECTION TABLE – 1 DUST CATCHER SHELL Description © 2007 MECON Limited All rights reserved Tolerance in mm Structural Page 72 of 83 GS-04 General Technical Specification Ellipticity (max. difference between diameters ) of the cylindrical and conical portions. 0.005 of the theoretical diameter of the cylinder and conical portion. TABLE – 2 BLAST FURNACE SHELL DESCRIPTION DEVIATION IN mm Ellipticity (max. difference in diameters) of a course. + 0.002 of the theoretical diameter of the course. 0.1 of shell thickness but not more than 3 mm. Stepping of the edges of plates in the vertical and circular weld joint. Local warping of shell along the generatrix and periphery as measured by gauge over the length of 1500 mm. © 2007 MECON Limited All rights reserved Structural Page 73 of 83 Not more than 15 mm. GS-04 General Technical Specification Caving in or bulging of joints measured by gauge over a length of 200 mm. 5 Note : H - height measured from the base of the point of alignment. TABLE – 3 COVERAGE OF NDT FOR WELDS STRUCTURE NORMS FOR CONTROLLING AS A % OF PLACES TO BE TOTAL LENGTH OF WELDING ( NOT SUBJECTED TO LESS THAN ) FOR RADIOGRAPHIC TESTING COMPULSORILY RADIOGRAPHIC TESTING ULTRMANUAL & AUTOMATIC SONIC SEMITESTING AUTOMATIC BF Shell 100 Stoves, hot 100 blast main & bustle main © 2007 MECON Limited All rights reserved 3 2.0 10 1.5 Structural Page 74 of 83 Portions of the welded joint found defective by ultrasonic testing Portions of the welded joint found defective by ultrasonic testing and crossing of welded joint GS-04 General Technical Specification Dust catcher, Junction & places of variable cross sections by the following norms without ultrasonic testing with 100 ultrasonic testing Portions of gas pipelines from BF to DC & DC to GCP -- -- 3 1.5 Crossing joint 1 0.5 Portions of the welded joints found defective by ultrasonic welding 1 0.5 of welded Portions of the welded joints found defective by ultrasonic testing TABLE – 4 ERECTION TOLERANCES © 2007 MECON Limited All rights reserved Structural Page 75 of 83 GS-04 General Technical Specification DESCRIPTION TOLERANCE (mm) COLUMNS Deviation of column axes at foundation top level with respect to true axes In longitudinal direction In lateral direction Deviation in the level bearing surface of columns at foundation top level with respect to true level . Out-of-plumbness (verticality of column axis from true vertical axis, as measured at column top : For columns without any special requirements Up to and including 30 M height Over 30 M height For columns with special requirement like cranes or such similar requirements. Upt o and including 30 M height ±5 ± H/1000 or ±25 mm whichever is less. ± H/1200 or ±35 mm max. ± H/1000 or ±20 mm whichever is less. ± H/1500 or ±25 mm max. Over 30 M height Deviations in straightness in longitudinal and transverse plans of columns at any point along the height. © 2007 MECON Limited All rights reserved ±5 ±5 Structural Page 76 of 83 ± H/1000 or ±10 mm whichever is less. GS-04 General Technical Specification Difference in the erected position adjacent pairs of columns along with cross width of building prior to connecting trusses/beams with respect to true distance. ±5 Deviation in any bearing or seating level with respect to true level. ±5 Deviation in difference in bearing levels of a member on adjacent pair of columns both across and along the building. ±5 Note : Tolerance specified under 3(a) & 3(b) should be read in conjunction with 4 & 5. 'H' above is the column height in mm. contnd.. DESCRIPTION TOLERANCES (mm) TRUSSES ± 1/250 of height of Shift, at the centre of span of top chord member truss at centre of span with respect to the vertical plan passing through or the centre of bottom chord. ± 15 mm whichever is less. Lateral shift of top chord of truss at the centre of ± 1/1500 of height of span from the vertical plan passing through the truss at centre of span centre of supports of the truss. or © 2007 MECON Limited All rights reserved Structural Page 77 of 83 GS-04 General Technical Specification ± 10 mm whichever is less. Lateral shift in location of truss from its true vertical position. ± 10 mm Lateral shift in location of purlins from its true positions. ±5 Deviation in difference of bearing levels of L/1200 or ± 20 mm trusses or beam from the true difference. whichever is less ( L = span ) contnd.. DESCRIPTION TOLERANCES (mm) CRANE GIRDERS & RAILS Shift in the centre line of crane rail with respect ± ( web thickness + 2 to centre line of web of crane girder. )/2 Shift in plan of alignment of crane rail with respect to true axis of crane rail at any point. ±5 Deviations in crane track gauge with respect to true crane gauge. For track gauge up to and including 15 M. ±5 For track gauge more than 15 M. ( 5 + 0.25 ( S-15 ) subject to a max. of 10 mm, where S in © 2007 MECON Limited All rights reserved Structural Page 78 of 83 GS-04 General Technical Specification meters is true track gauge. Deviations in crane rail level at any point from true level. ± 10 Difference in levels between crane track rails ( across the bay ) at : Support of crane girder Mid span of crane girders ± 15 ± 20 2 mm subject to Relative shift of crane rail surfaces at a joint in grinding of surfaces plan and elevations. for smooth transitions. Relative shift in location of crane stops ( end 1/1000 of track gauge S in mm subject to buggers ) along the crane track gauge. max. of 20 mm CHIMNEYS & TOWERS Out of plumbness ( vertically from the true 1/1000 of the height of vertical axis ). chimney or tower in mm. BUNKERS © 2007 MECON Limited All rights reserved Deviation in length of bunker from the true length. ± 1/1000 of length in mm Deviation in width of bunker from the true width. ± 1/1000 of width in mm Deviation in height height. ± 1/1000 of height in mm of bunker from the true Structural Page 79 of 83 GS-04 General Technical Specification BF SHELL Ellipticity ( the maximum difference in diameter in diameter ) of courses . 0.002 of the theoretical diameter of the courses. STOVE SHELL The dome centre bottom centre. shift with respect to the Ellipticity ± 20 0.002 of the nominal diameter TOP STRUCTURES Shift of frame centre from the designed position. Non horizontality of girders ± 20 mm 3 mm per 1 m of girder length. DOWN COMERS Erection and sag of down comers 0.0015 L but not more than 80 mm. ( L is the length of pipeline ) GAS PIPELINE SUPPORTS © 2007 MECON Limited All rights reserved Structural Page 80 of 83 GS-04 General Technical Specification Deviations of support axes from the vertical 0.002 h, but not more plane. than 20 mm, h is the height of the support. GAS & AIR Distortion of flange /surfaces (except for the 2 mm per 1 m of furnace top one ) with respect to the branch flange diameter. pipe/ pipe socket axis. DUST CATCHER Ellipticity 0.003 of the nominal diameter of the course. BUSTLE PIPE The deviations of the bottom level ( of the shell ) of the ring pipe ( measured along the axis of air tuyere ) from the designed one. Ellipticity © 2007 MECON Limited All rights reserved ± 10 mm 0.003 of the theoretical diameter. Structural Page 81 of 83 GS-04 General Technical Specification Note : The tolerances given at Sections 11 and 12 above, are meant as general guidelines , mainly for technological structures , and for those not covered in IS Codes. Tolerances for fabrication and erection in general, shall be as per stipulations of IS : 7215-1974 , and IS : 12843 -1989. In case of a conflict between the guidelines given in IS Codes and this Specification, those specified herein shall prevail. ANNEXURE-A Permissible deviations in pitch and gauge of holes for bolts of normal accuracy ( high strength bolts included ) Hole diameter Permissible Description (mm) deviations In spacing (mm) 1 2 3 a) Deviation Upto 17.0 +1 in the hole Above 17.0 +1.5 diameter b) Ovality Upto 17.0; +1 (difference Above 17.0; +1.5 between the biggest and the smallest diameter) c) Curves, __ __ exceeding 1mm and © 2007 MECON Limited All rights reserved Permissible deviations in each group of holes Carbon Steel 4 Low Alloyed Steel 5 No limits No limits Not permissible Structural Page 82 of 83 GS-04 General Technical Specification cracks on the hole edges d) (i) Non-coin- -cidence of holes in separate details of the assembled unit, upto 1mm (ii) Above 1 mm -upto 1.5 mm e) Slope of axis © 2007 MECON Limited All rights reserved -- -- Upto 50% Upto 50% -- Upto 10% Upto 10% Upto 30% No of the Limits thickness of unit Structural Page 83 of 83 No Limits GS-04 INSPECTION (CHAPTER-05) STEEL AUTHORITY OF INDIA LIMITED BHILAI STEEL PLANT GENERAL SPECIFICATION FOR QUALITY SYSTEM, INSPECTION & TEST OF PLANT / EQUIPMENT AT MANUFACTURER’S PREMISES (GS – 05) MECON LIMITED RANCHI – 834002 No. MEC/S/1901/11/38/0/00/00/F1889/R2 JULY, 2007 General Technical Specification CONTENTS SL. NO. DESCRIPTION PAGE NO. 01. GENERAL 1 02 QUALITY SYSTEM REQUIREMENTS 1 03 QUALITY ASSURANCE PLAN 1 04 CALIBRATION OF MEASURING EQUIPMENT 2 05 TEST CERTIFICATES & DOCUMENTS 2 06 INTERNAL INSPECTION TENDERER/MANUFACTURER 07 MANUFACTURING & INSPECTION SCHEDULE 3 08 METHOD OF UNDERTAKING INSPECTION & TESTING BY MECON/BSP 4 09 OBLIGATIONS OF SUCCESSFUL TENDERER 4 10 STAMPING AND ISSUE OF INSPECTION DOCUMENTS 5 11 GENERAL CLAUSES 5 BY SUCCESSFUL 3 ENCLOSURES: i) Form No. 11.20.(DQM)F-09 Rev-0 - QAP for Structural & Mechanical Equipment ii) Form No. 11.20.(DQM)F-10 Rev-0 - QAP for Electrical Equipment iii) Form No. 11.20.(DQM)F-11 Rev-0 - QAP for Refractory Materials iv) Form No. 11.20.(DQM)F-5/2 Rev-0 - Inspection Call Proforma v) LIST OF MECON OFFICES and Contact Address Details © 2006 MECON Limited All rights reserved Contents Page 1 of 1 GS-05 General Technical Specification GENERAL SPECIFICATION ON QUALITY SYSTEM, INSPECTION & TEST OF PLANT & EQUIPMENT AT MANUFACTURER'S PREMISES 1.0 GENERAL 1.1 Inspection & testing of plant & equipment shall be carried out by Consultant/ Purchaser at the works of successful tenderer during manufacturing and/or on final product to ensure conformity of the same with the acceptable criteria of technical specifications, approved drawings, manufacturing drawings and applicable national / international standards. 2.0 QUALITY SYSTEM REQUIREMENTS The successful tenderer must recognise the importance of quality and follow defined quality programme in all stages of. manufacturing and quality control activities of the product. Contractor must define and implement the tasks and controls that will provide needed assurance, in case manufacturing of product is sub-contracted either partly or fully and/or for the procured components of the product. All bought-out equipment or component shall be procured from vendors which are duly approved by the project authority. Consultant/ Purchaser reserve the right to verify the quality programme of tenderer & its vendors/sub- vendors to assure the effectiveness of the programme to meet the intended and specified quality of the product. 3.0 QUALITY ASSURANCE PLAN (QAP) 3.1 The successful tenderer shall furnish Quality Assurance Plan (QAP) for respective equipment after completion of detailed engineering and finalisation of billing schedule / equipment identification number for Consultant's approval at least one month prior to start of manufacturing. 3.2 QAP shall be prepared & furnished by Contractor in Form Nos. 11.20(DQM) F- 09,10 , 11 (specimen copy enclosed) / detailed manufacturing QAP for structural & mechanical equipment, electrical equipment and refractory materials respectively , QAPs must be submitted in four ( 4 ) sets duly signed and stamped by tenderer for MECON approval . 3.3 The successful tenderer shall indicate procurement source and furnish to Consultant, during the submission of QAP, copies of P.O., Sub-P.O., T.S., approved GA drawings/ data sheets & detailed manufacturing drawings, as backup reference materials for scrutiny & final approval by Consultant. The submission & subsequent approval of QAPs shall be ensured to be restricted to one round only. 3.4 Inspection and test requirements shall be decided with due consideration of factors like safety, duty cycle, operating conditions, equipment life, environmental conditions, place of installation and statutory regulations, as applicable, for a particular equipment. Any, additional type or special tests or routine tests if found necessary to establish the intended quality after detailed engineering then the same shall have to be incorporated in the QAP without any commercial implication. 3.5 Detailed QAP shall be prepared by the successful tenderer in consultation with their Sub-contractors / Manufacturers to avoid any complicacy later . © 2007 MECON Limited All rights reserved Inspection Page 1 of 5 GS-05 General Technical Specification 4.0 CALIBRATION OF MEASURING EQUIPMENT 4.1 All the measuring equipment used for inspection & testing shall be calibrated and appropriate accuracy class of measuring equipment shall be used. Calibration standards used for calibration of measuring equipment shall be traceable to national standards of National Physical Laboratory (NPL), New Delhi with unbroken chains of comparison. 4.2 Valid calibration certificate for all measuring equipment used during inspection and testing at manufacturer’s works, with traceability to national standards of NPL/ NABL accredited laboratories shall be furnished prior to undertaking inspection by Consultant/ Purchaser. Calibration certificate shall also indicate reference no. of calibration standards calibrated by NPL/NABL accredited laboratories and copies of such calibration certificates of calibration standards shall be included in the compiled dossiers of inspection/test results. 5.0 TEST CERTIFICATES AND DOCUMENTS 5.1 For each of the items being manufactured as per approved QAP , following test certificates and documents, as applicable for each of the equipment, in requisite copies including original, duly endorsed by the Manufacturer/successful tenderer with appropriate linkage to project, purchase order and acceptance criteria etc shall be submitted to Consultant/ Purchaser. i) Raw materials identification & physical and chemical test certificates for all materials used in manufacture of the equipment (except IS: 2062-1999 Gr.A & IS: 210-1993, FG-150). ii) WPS, PQR & WPQ documents as per applicable code. iii) Details of stagewise inspection & rectification records for fabricated items, castings, forgings and machined articles. iv) Control dimension chart with records of alignment, squareness etc. v) Manufacturer's material and performance/relevant test certificates for all bought-out items. vi) Details of heat-treatment and stress relieving charts as per specification. vii) Non-Destructive Test reports as per respective code. viii) Static/dynamic balancing certificate for rotating components/machines. ix) Hardness test certificate. x) Pressure/Leakage Test Certificates. xi) Performance Test Certificates for all characteristics. xii) Routine / type / calibration /acceptance / special test ( Type Tests etc) certificates for electrical items. © 2007 MECON Limited All rights reserved Inspection Page 2 of 5 GS-05 General Technical Specification xiii) Surface preparation and painting certificates. xiv) Certificates from competent authority for the items coming under statutory regulations. 5.2 Where physical and chemical test certificates of material are not available, the successful tenderer/Sub-contractor shall arrange to have specimens and test samples of the materials, tested in his own laboratory at his cost and submit the copies of test results in requisite numbers to Consultant/Purchaser for review. Number of test samples against each heat/cast/lot or batch of materials, as applicable shall be as per relevant Indian or International Standards. 5.3 Where facilities for testing do not exist in the successful tenderer/Sub-contractor's laboratories or in case of any dispute, samples and test pieces shall be drawn by the successful tenderer/Sub-contractor in presence of Consultant/ Purchaser and sealed sample shall be sent to any Govt. approved /NABL accredited laboratory for necessary tests at former’s own cost. 5.4 The Consultant/ Purchaser shall have the right to be present and witness all tests being carried out by the successful tenderer/Sub- contractor at their own laboratory or approved laboratories. Also, the Inspection Agency shall reserve the right to call for confirmatory test on samples, at his discretion. 6.0 INTERNAL INSPECTION BY SUCCESSFUL TENDERER/MANUFACTURER 6.1 Inspection and tests shall be carried out by Contractor/ Manufacturer in accordance with approved drawings, T.S., P.O., and approved QAP. They shall maintain records of each inspection and test carried out and signed documents shall be submitted to Purchaser/Consultant for verification. 6.2 The successful tenderer shall carry out their internal inspection & obtain clearance from statutory bodies e.g. IBR, CCE, TAC, Weights & Measures, safety, IE rules etc. prior to offering any equipment for Purchaser/Consultant's inspection in accordance with approved QAP. 6.3 The successful tenderer/ Manufacturers shall identify all the inspected equipment/component/raw materials & shall maintain the record of status of inspection viz. inspected & found acceptable, require rectification/rework, rejected etc. 6.4 The successful tenderer shall establish and maintain procedures to ensure that the product that does not conform to specified requirements, is prevented from inadvertent use or installation. The description of non-conformity that has been accepted subsequently by Consultant/ Purchaser by concession and/or of repairs, shall be recorded. Repaired and reworked product shall be offered for re- inspection to Consultant/ Purchaser alongwith records of corrective action taken. 7.0 MANUFACTURING AND INSPECTION SCHEDULE All contractors shall submit the schedule for manufacturing and inspection indicating equipment / components, sub- assembly/ assembly. Date of approval of drawings / data sheets. Address of manufacturer with contact person and scheduled date of inspection. Such reports shall be submitted to respective Consultant Inspecting Offices with a copy © 2007 MECON Limited All rights reserved Inspection Page 3 of 5 GS-05 General Technical Specification to Inspection Co- ordinating Office once in a month. These monthly reports shall state the planning for next three months. Submission of first reports must commence one month prior to commencement of manufacturing activities of the product. 8.0 METHOD OF UNDERTAKING CONSULTANT/PURCHASER 8.1 Inspection call shall be given only on readiness of the equipment/ assembly/ sub-assembly & after approval of all relevant drawings and QAP. In case, equipment/ assembly/ sub-assembly offered for inspection are found not ready, all the cost of visit of Consultant's engineer shall have to be borne by the successful tenderer. INSPECTION & TESTING BY If the equipment/assembly/sub-assembly after inspection found not acceptable, require rework and involve Consultant's re- inspection, all the cost of such re-inspections shall also have to be borne by the successful tenderer,. 8.2 Inspection call shall be floated to Consultant, in the enclosed Form No.11.20(DQM)F-05/2.REV-0 duly filled in, with ten days clear margin, enclosing all documents like test Certificates, Internal Inspection Reports, P.O., Sub-P.O., T.S., Approved QAP, approved GA drawings/ data sheets and manufacturing drawings. Inspection calls without above documents shall be treated as invalid and shall be ignored. The hard copy of such documents must also accompany a CD ( comprising computer readable files ) containing the identical documents . 8.3 The successful tenderer shall offer substantial quantities for economical inspection consistent with the size of order. 8.4 On receipt of the Inspection call, pertaining to particular package / equipment / item, QA & Inspection group of Consultant, Ranchi ( Overall co-ordinating office for Inspection activities ) shall organize inspection visit or will issue Inspection assignment to other Consultant’s office ( based on nearness to the vendor's manufacturing works / relevant job expertise ). For further inspection pertaining to the same package / equipment / item, successful tenderer may forward the subsequent inspection calls to the respective Consultant’s offices ( as identified per initial assignment ), with a copy to QA & Inspection Section, Ranchi. 9.0 OBLIGATIONS OF SUCCESSFUL TENDRER 9.1 The successful tenderer shall provide all facilities and ensure full and free access of the Inspection Engineer of Purchaser/Consultant to their own or their Sub-Contractor's premises at any time, during contract period, to facilitate him to carry out inspection & testing of the product during or after manufacture of the same. 9.2 The successful tenderer shall delegate a Representative / Co-ordinator to deal with Consultant/ Purchaser on all inspection matters. Representative of successful tenderer shall be present during all inspection at Sub-Contractor's works. The successful tenderer shall comply with instructions of Consultant/ Purchaser fully and with promptitude. 9.3 9.4 The successful tenderer/ Sub-Contractor shall provide all instruments, tools, necessary testing & other inspection facilities to Consultant/ Purchaser free of cost for carrying out inspection. 9.5 The cost of testing welds by ultrasonic, radiographic and dye penetration tests etc. in the fabrication workshop shall be borne by the successful tenderer .These tests need to be © 2007 MECON Limited All rights reserved Inspection Page 4 of 5 GS-05 General Technical Specification witnessed by ASNT/ISNT Level-II qualified NDT personals 9.6 The successful tenderer shall ensure that the equipment/assembly/ component of the plant and equipment required to be inspected, are not dismantled or dispatched before inspection. 9.7 The successful tenderer shall not offer equipment for inspection in painted condition unless otherwise agreed in writing by Consultant/ Purchaser. 9.8 The successful tenderer shall ensure that the equipment and materials once rejected by the Consultant/Purchaser, are not re-used in the manufacture of the plant and equipment. Where parts rejected during inspection have been rectified as per agreed procedures laid down in advance, such parts shall be segregated for separate inspection and approval, before being used in the work. 10.0 STAMPING AND ISSUE OF INSPECTION DOCUMENTS 10.1 Inspection Memo:- For rejected items/items, which do not conform to Technical Specification in one or more quality characteristics requiring rectification / rework, Inspection Memo shall be issued indicating therein the details of observation & remarks. All the non-conformities with respect to specification of the product shall be indicated in the Inspection Memo for further quality control by successful tenderer. 10.2 Inspection Certificate:- On satisfactory completion of final inspection & testing, all accepted plant & equipment shall be stamped suitably and Inspection Certificate shall be issued by the Consultant for the accepted items. 11.0 GENERAL CLAUSE 11.1 Inspection & tests carried out by Consultant/Purchaser shall not absolve the responsibility of the successful tenderer/ Manufacturer to provide acceptable product as per the terms of contract nor shall it preclude subsequent rejection. 11.2 Purchaser/ Consultant reserve the right to inspect any product at any stage of manufacturing beyond pre-identified stages & hold points of approved QAP. © 2007 MECON Limited All rights reserved Inspection Page 5 of 5 GS-05 FORM NO. 11.20 (DQM) F-09, REV-0 ORDER NO. & DATE QUALITY ASSURANCE PLAN FOR SUB - CONTRACTOR ORDER NO. & DATE STRUCTURAL & MECHANICAL EQUIPMENT CONTRACTOR QAP shall be submitted for each of the equipment separately w ith break up of assembly / sub-assembly & part/component or for group of equipment having same specification. 2 Use numerical codes as indicated for extent of inspection & tests and submission of test certificates & documents. Additional codes & description for extent of inspection & tests may be added as applicable for the plant and equipment. 3 Separate identification number w ith quantity for equipment shall be indicated w herever equipment having same specification belonging to different facilities are grouped together. 4 Code MFG : PACKAGE NAME Code Description 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 13. Heat Treatment 14. Pressure Test 15. Leakage test 16. Balancing 17. Vibration Test 18. Amplitude test ABBREVIATIONS USED : : Description 1. Visual(Welding etc.) 2. Dimensional 3. Fitment & Alignment 4. Physical Test(Sample) 5. Chemical Test (Sample) 6. Ultrasonic Test 7. Magnetic Particle Test(MPT) 8. Radiography test 9. Dye Penetration Test 10. Metallographic Exam. 11. Welder's Qualification & Weld Procedure Test 12. Approval of Test and Repair Procedure Weight in tonnes (T) must be indicated under column 5 for each item. Estimated w eights may be indicated w herever actual w eights are not available. CONTR PACKAGE NO. CODES FOR EXTENT OF INSPECTION, TESTS, TEST CERTIFICATES & DOCUMENTS : INSTRUCTIONS FOR FILLING UP : 1 PROJECT CONTRACTOR MANUFACTURER E Q U I P M E N T Code Sponge test Dust/Water Ingress test Friction Factor Test Adhesion Test Performance Test/ Characteristic curve No. Load/Free Running Test Load/Overload Test Measurement of speeds Accoustical test Geometrical Accuracy Repeatability and Positioning Accuracy Proving Test Description 34. Internal Inspection report by Contractor 35. Hardness test 36. Spark test for Lining 37. Calibration 38. Safety device test 39. Ease of Maintenance 40. Thickness measurement of Zinc coating 31. Surface Preparation 32. Manufacturer's Test Certificates for bought out items 33 IBR/Other statutory agencies' compliance certificate D E T A I L S Description (w ith equipment Identification No. heading,place of use and No. No / M INSPECTION AND TESTS Quantity 3 4 Manufacturer's Expected Sche- T Name and Address dule of Final 5 6 brief specification) 1 2 for MECON ( Stamp & Signature ) D1. Approved GA draw ings D2. Information and other reference drg / stamped drgs released for manufacture D3. Relevant catalogues D4. Bill of Material/ item no./ identification. D5 Matchmark details D6 Line/Layout diagram D7 Approved erection procedures D8 Unpriced sub P.O.w ith specification and amendments if any D9. Calibration Certificate of all measuring instrument and gauges. D10. Ordering Specification Raw Material and Inprocess Sl. DOCUMENTS : Test Certificates & stage Inspection Final Inspection / Test by Inspn MFR CONTR MECON MFR CONTR MECON 7 8 9 10 11 12 13 For CONTRACTOR / SUB - CONTRACTOR (Stamp & Signature ) Acceptance Criteria documents to be Standards/IS/BS/ REMARKS/ submitted to MECON ASME/Norms and SAMPLING PLAN Documents 14 15 ( Q . A . P . NO. TO BE ALLOTTED BY MECON ) NO. / / / MSHEET : OF 16 REV. FORM NO. 11.20 (DQM) F-09, REV-0 CONTINUATION SHEET E Q U I P M E N T D E T A I L S INSPECTION AND TESTS Raw Material and Inprocess Sl. Description (w ith equipment Identification Quantity No. heading,place of use and No. No / M 3 4 Manufacturer's Expected Sche- T Name and Address dule of Final 5 6 brief specification) 1 2 for MECON ( Stamp & Signature ) Test Certificates & stage Inspection Final Inspection / Test by Inspn MFR CONTR MECON MFR CONTR MECON 7 8 9 10 11 12 13 For CONTRACTOR / SUB - CONTRACTOR (Stamp & Signature ) Acceptance Criteria documents to be Standards/IS/BS/ REMARKS/ submitted to MECON ASME/Norms and SAMPLING PLAN Documents 14 15 ( Q . A . P . NO. TO BE ALLOTTED BY MECON ) NO. / / / MSHEET : OF 16 REV. FORM NO. 11.20 (DQM) F-10, REV-0 QUALITY ASSURANCE PLAN FOR ELECTRICAL EQUIPMENT CONTRACTOR ORDER NO. & DATE SUB - CONTRACTOR PROJECT PACKAGE NO. PACKAGE NAME ORDER NO. & DATE CODES FOR EXTENT OF INSPECTION, TESTS, TEST CERTIFICATES & DOCUMENTS : INSTRUCTIONS FOR FILLING UP : 1 QAP shall be submitted for each of the equipment separately w ith break up of assembly / sub-assembly & part/component or for group of equipment having same specification. 2 Use numerical codes as indicated for extent of inspection & tests and submission of test certificates & documents. Additional codes & description for extent of inspection & tests may be added as applicable for the plant and equipment. 3 Separate identification number w ith quantity for equipment shall be indicated w herever equipment having same specification belonging to different facilities are grouped together. 4 Code MFG : 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 12. Routine test as per relevant IS/other standard. 13. Type tests as per relevant IS/ other standard. ABBREVIATIONS USED : : Code Description 1. Visual 2. Dimensional 3. Fitment & Alignment 4. Physical Test(Sample) 5. Chemical Test (Sample) 6. Ultrasonic Test 7. Magnetic Particle Test(MPT) 8. Radiography test 9. Dye Penetration Test 10. Measurement of IR Value : a) Before HV Test b) After HV Test 11. High voltage test/Dielectric test. Weight in tonnes (T) must be indicated under column 5 for each item. Estimated w eights may be indicated w herever actual w eights are not available. CONTR Description CONTRACTOR Code Impalse Test. Partial Discharge Test. Heat run test/Temp. rise Test. Enclosure protection Test. Calibration. Noise & Vibration. Test Certificates for bought out components. Tank pressure Test. Paint shade verification. Short time rating. Operation & functional check. Overspeed Test. DOCUMENTS : D1. Approved GA draw ings D2. Approved single line / schematic diagram. D3. Catalogues / Approved data sheet D4. Approved bill of materials. D5. Unpriced P.O. copy. D6. Calibration Certificate of all measuring instrument and gauges 26. Flame proof Test 27. Clearance and creepage distance. 28. Acceptance Tests as per relevant IS MANUFACTURER E Q U I P M E N T D E T A I L S INSPECTION AND TESTS Raw Material and Inprocess Sl. Description (w ith equipment Identification No. heading,place of use and No. No / M Quantity 3 4 Manufacturer's Expected Sche- T Name and Address dule of Final 5 6 brief specification) 1 Description 2 for MECON ( Stamp & Signature ) Test Certificates & stage Inspection Final Inspection / Test by Inspn MFR CONTR MECON MFR CONTR MECON 7 8 9 10 11 12 13 For CONTRACTOR / SUB - CONTRACTOR (Stamp & Signature ) Acceptance Criteria documents to be Standards/IS/BS/ REMARKS/ submitted to MECON ASME/Norms and SAMPLING PLAN Documents 14 15 ( Q . A . P . NO. TO BE ALLOTTED BY MECON ) NO. / / / ESHEET : OF 16 REV. FORM NO. 11.20 (DQM) F-10, REV-0 CONTINUATION SHEET E Q U I P M E N T D E T A I L S INSPECTION AND TESTS Raw Material and Inprocess Sl. Description (w ith equipment Identification Quantity No. heading,place of use and No. No / M 3 4 Manufacturer's Expected Sche- T Name and Address dule of Final 5 6 brief specification) 1 2 for MECON ( Stamp & Signature ) Test Certificates & stage Inspection Final Inspection / Test by Inspn MFR CONTR MECON MFR CONTR MECON 7 8 9 10 11 12 13 For CONTRACTOR / SUB - CONTRACTOR (Stamp & Signature ) Acceptance Criteria documents to be Standards/IS/BS/ REMARKS/ submitted to MECON ASME/Norms and SAMPLING PLAN Documents 14 15 ( Q . A . P . NO. TO BE ALLOTTED BY MECON ) NO. / / / ESHEET : OF 16 REV. FORM NO.11.20(DQM) F-11 REV-0 QUALITY ASSURANCE PLAN FOR CONTRACTOR ORDER NO. & DATE QAP shall be submitted for each of the equipment separately with break up of assembly / sub-assembly & part/component or for group of equipment having same specification. 2 Use numerical codes as indicated for extent of inspection & tests and submission of test certificates & documents. Additional codes & description for extent of inspection & tests may be added as applicable for the plant and equipment. 3 Separate identification number with quantity for equipment shall be indicated wherever equipment having same specification belonging to different facilities are grouped together. 4 Weight in tonnes (T) must be indicated under column 5 for each item. Estimated weights may be indicated wherever actual weights are not available. Code ABBREVIATIONS USED : CONTR : CONTRACTOR MFR : MANUFACTURER E Q U I P M E N T 1 Description (with equipment heading,place of use and brief specification) 2 for MECON ( Stamp & Signature ) PACKAGE NAME CODES FOR EXTENT OF INSPECTION, TESTS, TEST CERTIFICATES & DOCUMENTS : INSTRUCTIONS FOR FILLING UP : Sl. No. PACKAGE NO. REFRACTORY MATERIALS SUB - CONTRACTOR ORDER NO. & DATE 1 PROJECT Description 18. Drying & firing shrinkage 19. Sieve analysis 20. Warpage 21. Drip slag test 22. Permeability test 23. Hydration resistance test 24. Lap joint strength 25. Abrasion resistance 26. Cold bonding strength 27. Oxidation resistance 28. Workability 29. Surface area 30. Corrosion resistance 31. Consistency 13. Reversible thermal expansion 14. Resistance to dis-integration effect of carbon monoxide gas. 15. Water absorption 16. Acid resistance 17. Thermal conductivity 32. Internal Inspection Report D E T A I L S Identification No. 3 Quantity No / M 4 T Manufacturer's Name and Address 5 6 Code Description 1. Visual 2. Dimensions and geometry 3. Chemical composition 4. Apparent porosity 5. True specific gravity 6. Bulk density/true density 7. Cold crushing strength 8. Pyrometric cone equivalent 9. Refractoriness under load 10. Spalling resistance 11. Permanent linear change after heating 12. Modulus of Rupture/ Flexural strength Expected Schedule of Final Inspn 7 DOCUMENTS : D1. Laboratory test report D2. Dimensional drgs. showing plan, elevation, side view & cross sectional view duly approved. D3. Copies of sub P.O. & Technical Specification. D4. Calibration Certificate of all measuring instruments and gauges. 33.Safe working temp. 34. Lot sampling 35. Part assembly 36.Control assembly. INSPECTION AND TESTS Raw Material and Inprocess stage Inspection Final Inspection / Test by MFR 8 For CONTRACTOR / SUB - CONTRACTOR (Stamp & Signature ) CONTR 9 MECON 10 MFR 11 CONTR 12 Test Certificates & documents to be submitted to MECON MECON 13 14 ( Q . A . P . NO. TO BE ALLOTTED BY MECON ) NO. / / / RSHEET : 1 OF 2 Acceptance Criteria Standards/IS/BS/ ASME/Norms and Documents 15 REMARKS/ SAMPLING PLAN 16 REV. CONTINUATION SHEET FORM NO.11.20(DQM) F-11 REV-0 E Q U I P M E N T Sl. No. 1 Description (with equipment heading,place of use and brief specification) 2 for MECON ( Stamp & Signature ) D E T A I L S Identification No. 3 Quantity No / M 4 T Manufacturer's Name and Address 5 6 Expected Schedule of Final Inspn 7 INSPECTION AND TESTS Raw Material and Inprocess stage Inspection Final Inspection / Test by MFR 8 For CONTRACTOR / SUB - CONTRACTOR (Stamp & Signature ) CONTR 9 MECON 10 MFR 11 CONTR 12 Test Certificates & documents to be submitted to MECON MECON 13 14 ( Q . A . P . NO. TO BE ALLOTTED BY MECON ) NO. / / / RSHEET : 2 OF 2 Acceptance Criteria Standards/IS/BS/ ASME/Norms and Documents 15 REMARKS/ SAMPLING PLAN 16 REV. Form No. 11.20(DQM)F-05/2 Rev.0 Page No. 1 of 1 INSPECTION CALL PROFORMA Inspection Call No. Date : Project Purchaser Contractor's Order No. & Date Place of Inspection with address, Fax & Ph. No. Name & Designation of Contact Person with Ph. No. Contractor Sub-Contractor with address, Fax & Ph. No. Proposed Date of Inspection Manufacturer's Off-day List of items offered for inspection : Item Item Description Identication No. Drawing No. with Revision Drawing QAP No. & Approval Status Status A/AAN/INF Quantity (No./M) with tonnage Total Total Offered Ordered Accepted A = Approved, AAN = Approved as Noted, INF = Information Category List of documents & Test Certificates enclosed in four (4) sets. Description Ref No. & Date Description Ref No. & Date for Contractor/Sub-Contractor LIST OF MAJOR INSPECTING OFFICES OF MECON SL. NO. DETAILED ADDRESS AREA OF OPERATION 1. D.G.M. Inspection Section MECON Ltd., 89, South End Road, Basavanagudi, Bangalore-560 004 (Karnataka) Karnataka ,A.P.& Kerala Gram : MECONIND Fax : 080-6576352 Phone : 080-6571661-68/6576476 E-mail : bangalore@mecon.co.in 2. Dy.General Manager MECON Ltd., Ispat Bhawan, Ist floor, Bhilai-490 001 (M.P. ) Bhilai, Nagpur, Raipur, Bilaspur, Bhopal,Satna & Katni Gram : MECON Fax : 0788-224452 Phone : 0788-220107/224101/224454 E-mail : bhilai@mecon.co.in List of Inspecting Offices_Seq_9 1 of 3 As on 7/26/2007 LIST OF MAJOR INSPECTING OFFICES OF MECON SL. NO. DETAILED ADDRESS AREA OF OPERATION 4. DGM I/C MECON Ltd., J-5, Plot No. 3552, 6th Aveniue, Annanagar East, Chennai- 600 102 Chennai & total Tamil Nadu Gram : MECONIND Fax : 044-26261474 Phone : 044-26261911,26269743 E-mail : chennai@mecon.co.in 5. DGM Inspection Section MECON Ltd., 50, Chwringhee Road, Kolkata- 700 071 (W.B.) Kolkata, Howrah, Bhubaneswar, Cuttack & Baripada Gram : MECONCAL Fax : 033-22824441 Phone : 033-22822381 to 83,22822284,22822857 E-mail :kolkata@mecon.co.in mec-cal@datatone.in 6. DGM (I/C) Inspection Section, MECON Ltd., 3rd Floor, Tower No. 7, International Infotech Park, Vashi Railway Station Complex, Vashi, Navi Mumbai-400 703 Maharashtra (except Nagpur), Gujarat & Goa Fax : 022-27812275 Phone : 022-27812155 to 58, 27812276 E-mail : mecon@bom5.vsnl.net.in mumbai@mecon.co.in List of Inspecting Offices_Seq_9 2 of 3 As on 7/26/2007 LIST OF MAJOR INSPECTING OFFICES OF MECON SL. NO. 7. DETAILED ADDRESS AREA OF OPERATION ! DGM Inspection Section, MECON Ltd., Scope Minar, 14th & 15th Floor, North Tower, Laxmi Nagar, Delhi-110 092 Delhi, Punjab, Rajasthan Fax : 011-22401203,22041214 Phone : 011-22041201/22041315 22041238 E-mail : delhi@mecon.co.in 8. Mr. P. Dutta, DGM (I/C) QA & Inspection Section MECON Ltd., Ranchi-834 002 (Jharkhand) Ranchi, Dhanbad, Jamshedpur, Allahabad, Naini and all over India, if need arises for whatever reason. Gram : MECON Fax : 0651-2480216/2480002/2262194 Phone : 0651-2481002/2481216 Extn : 7330 2482183 (P & T) Direct E-mail : insp@mecon.co.in, pdutta@mecon.co.in List of Inspecting Offices_Seq_9 3 of 3 As on 7/26/2007 PAINTING (CHAPTER-09) STEEL AUTHORITY OF INDIA LIMITED BHILAI STEEL PLANT GENERAL SPECIFICATION FOR PAINTING (GS – 09) MECON LIMITED RANCHI - 834002 No. MEC/S/1901/11/38/0/00/00/F1889/R2 JULY, 2007 General Technical Specification CONTENTS Sl. No. Description Page No. 01 GENERAL 1 02 SURFACE PREPARATION 1 03 PAINT APPLICATION 3 04 PAINTING SCHEMES 6 05 GUARANTEE 7 ANNEXURE-01 – SURFACE PREPARATION GRADE 8 ANNEXURE-02 – PAINT MATERIALS 9 ANNEXURE-03 – PAINTING SCHEME 15 ANNEXURE-04 – COLOUR CODE 18 © 2007 MECON Limited All rights reserved Painting Page 1 of 1 GS-09 General Technical Specification 01 G E N E R AL 01.01 This specification covers the materials, tools, facilities and quality requirement for surface preparation and painting of steel structures, equipment, piping, ducts, chutes, wood work etc. 01.02 This is only a general guideline of the painting scheme to be followed by the Tenderer. However, in case a specific painting procedure is stipulated in any tendering specification, then this general guideline shall be s u p e r c e d e d . A n y s p e c i a l c a s e w h i c h m a y a r i s e f r o m t im e t o t i m e s h a l l b e dealt with individually on the merit of each case 01.03 The term “painting” referred herein covers rust preventive, fungus/insects preventive and decorative coating along with surface protection of the following area but not limited to the areas indicated below. i) ii) iii) iv) v) vi) Structural steel works Mechanical equipment Electrical equipment Instrumentation and control equipment. Pipe work O x yg e n p l a n t , e t c . 01.04 Surfaces made of asbestos, aluminum, brass, bronze, galvanized steel, s t a i n l e s s s t e e l , c a s t i r o n a n d o t h e r c o r r o s i o n r e s i s t a n t a l l o ys a n d r u b b e r / s yn t h e t i c p o l y m e r / f i b e r r e i n f o r c e m e n t p l a s t i c a n d b u r i e d p i p e w o r k are not required to be painted unless specified except for aesthetic purposes or for identification bands, wherever relevant. 01.05 T h e c o m p l e t e p a i n t s ys t e m f o r a n y i t e m i n c l u d e s t h e f o l l o w i n g b a s i c activities: i) ii) iii) iv) Proper surface preparation Application of primer coats Application of intermediate coats Application of finished coats All the above coats shall be of quality paint products and of approved m ak e . T h e s c o p e o f w o r k s h a l l a l s o i n c l u d e s u p p l y o f a l l p a i n t m a t e r i a l s a s per specification described herein. 01.06 I f t h e c o n t r a c t o r d e s i r e s t o a d o p t a l t e r n a t i v e p a i n t s ys t e m f o r a n y s p e c i f i c i t e m f o r a n i m p r o v e m e n t o r e q u i v a l e n t t o t h e s ys t e m s p e c i f i e d h e r e - i n o r as per recommendations of paint manufacturer, may do so subject to purchaser’s approval in advance. 02 S U R F AC E 02.01 Surface preparation required for paint application, shall be such as to clean the surface thoroughly of any material which will be conducive to premature failure of the paint substrates. © 2007 MECON Limited All rights reserved P R E P AR AT I O N Painting Page 1 of 19 GS-09 General Technical Specification 02.02 All surfaces shall be cleaned of loose substances, and foreign materials, such as dirt, rust, scale, oil, grease, welding flux, etc. in order that the prime coat is rigidly anchored to the virgin metal surface. The surface preparation shall confirm to pictorial representation of surface quality g r a d e o f S we d i s h S t a n d a r d s I n s t i t u t i o n SIS – 055900 or equivalent standards such as SSPC – VIS – 1.67 or DIN 55928(Part 4) or BS 4232 or IS 1477 – 1971 (Part I) 02.03 The acceptable surface preparation quality / grade are described under e a c h p a i n t s ys t e m . T h e p r o c e d u r e s i n c l u d e s o l v e n t c l e a n i n g , h a n d t o o l cleaning, power tool cleaning, blast cleaning, wood surface cleaning, f l a m e c l e a n i n g a n d p i c k l i n g . T h i s wi l l e n s u r e s u r f a c e q u a l i t y a s r e q u i r e d by the specific primer paint. For ready reference surface preparation quality grade to be adopted in respect of SIS 055900 and DIN 55928 (part-4) is given in Annexure-01. 02.03.01 Solvent Cleaning T h e s u r f a c e s h a l l b e c l e a n e d b y w i p i n g , i m m e r s i o n , s p r a yi n g o r v a p o u r c o n t a c t i n g o f a s u i t a b l e s o l v e n t o r wa s h i n g wi t h a n e m u l s i o n o r a l k a l i n e solution to remove oil, grease, dirt, old paint, etc. Solvent cleaning shall n o t r e m o v e r u s t , s c a l e s , m i l l s c a l e s o r we l d f l u x . T h e r e f o r e , b e f o r e a p p l i c a t i o n o f p a i n t , s o l v e n t c l e a n i n g s h a l l b e f o l l o we d b y o t h e r c l e a n i n g procedures as stated in subsequent clauses. 02.03.02 Hand Tool Cleaning The surface shall be cleaned manually by vigorous wire brushing as per g r a d e S t - 2 q u a l i t y o f S we d i s h S t a n d a r d I n s t i t u t i o n S I S 0 5 5 9 0 0 a n d D I N 555928. This method effectively removes loosely adherent materials, but would not affect residues of rust or mill scales that are intact are firmly a d h e r e n t . F i n a l l y t h e s u r f a c e i s t o b e c l e a n e d wi t h a v a c u u m c l e a n e r o r with clean compressed air or with clean brush. After preparation the surface shall have a faint metallic shine. The appearance shall correspond to the prints designated St – 2. 02.03.03 Power Tool Cleaning The surface shall be cleaned by electric or pneumatic tools, such as brushes, sanding machines, disc abrasive grinder, rotar y disc scaler etc. t o S t – 3 q u a l i t y. T h e t o o l s s h a l l b e u s e d c a r e f u l l y t o p r e v e n t e x c e s s i v e roughening of surface and formation of ridges and burrs. This method will remove loosely adherent materials but would not affect residues of rust or mill scales that are firmly adherent and intact. 02.03.04 Blast Cleaning The surface shall be cleaned by impingement of abrasive materials, such as graded sand at high velocity created by clean and dr y compressed air blast as per the grade according to Swedish Standard Institution SIS 0 5 5 9 0 0 . T h i s m e t h o d wi l l r e m o v e l o o s e l y a d h e r e n t m a t e r i a l s a s w e l l a s adherent scales and mill scales. Prior to application of blast, heavy deposit of oil and grease are removed by solvent cleaning excessive © 2007 MECON Limited All rights reserved Painting Page 2 of 19 GS-09 General Technical Specification surface scales are removed by hand tools or power tool cleaning. The extent of removal of adherent scales is varied, depending on the application and are defined by the surface quality grades Sa1, Sa2, Sa2.5 and Sa3 in the order of increasing cleanliness. The blast cleaning is not recommended for sheet metal work. 02.03.05 Flame Cleaning T h e s u r f a c e i s c l e a n e d b y r a p i d h e a t i n g b y m e a n s o f o x ya c e t yl e n e f l a m e to loosen the adherent scales, followed immediately by wire brushing. T h i s m e t h o d w i l l r e m o v e l o o s e l y a d h e r e n t m a t e r i a l s a s we l l a s m o s t o f t h e a d h e r e n t s c a l e s a n d m i l l s c a l e s . I n o r d e r t o m i n i m i ze o r p r e v e n t d i s t o r t i o n f l a m e c u t t i n g s h a l l n o t b e u s e d o n m em b e r s h a v i n g t h i c k n e s s o f 6 m m a n d lower. 02.03.06 Pickling In this method the surface is cleaned of mill scales, rust or rust scales by c h e m i c a l r e a c t i o n o r e l e c t r o l ys i s o r b o t h . 03. P AI N T AP P L I C AT I O N 03.01 Paints 03.01.01 Paint shall be applied in accordance with paint manufacturer’s r e c o m m e n d a t i o n s . T h e wo r k s h a l l g e n e r a l l y f o l l o w I S 1 4 7 7 – 1 9 7 1 ( P a r t I I ) for jobs carried out in India and SSPC-PA-1 or DIN 55928 or equivalent for jobs carried out outside India. 03.01.02 General compatibility between primer and finishing paints established by the paint manufacturer supplying the paints. 03.01.03 In the event of conflict between this general procedure on painting and the paint manufacturer’s specification, the same shall be immediately brought to the notice of the Purchaser. Generally in cases of such conflicts, manufacturer’s specifications/recommendations shall prevail. 03.01.04 B e f o r e b u yi n g t h e p a i n t i n b u l k , i t i s r e c o m m e n d e d t o o b t a i n s a m p l e o f paint and establish “Control Area of Painting”. On Control Area, surface preparation and painting shall be carried out. 03.01.05 If required, samples of paint shall be tested in laboratories to establish quality of paint with respect to: (i) (ii) (iii) (iv) (v) (vi) 03.01.06 shall be Viscosity Adhesion/Bond of paint in steel surfaces Adhesion/Simulated salt spray test. C h e m i c a l a n a l ys i s ( p e r c e n t a g e o f s o l i d s b y w e i g h t ) Normal wear resistance as encountered during handling & erection. Resistance against exposure to acid fumes, etc. W h o l e q u a n t i t y o f p a i n t f o r a p a r t i c u l a r s ys t e m o f p a i n t s h a l l b e o b t a i n e d f r om t h e s a m e m a n u f a c t u r e r . © 2007 MECON Limited All rights reserved Painting Page 3 of 19 GS-09 General Technical Specification 03.01.07 The main Contractor shall be responsible for supply of paints and this responsibility shall not be passed on to the sub-contractor. 03.01.08 The painting material as delivered to the Contractor, must be in the manufacturer’s original container bearing thereon manufacturer’s name b r a n d a n d d e s c r i p t i o n . P a i n t / P a i n t i n g m a t e r i a l i n c o n t a i n e r s wi t h o u t l a b e l s or with illegible labels shall be rejected, removed from the area and shall not be used. 03.01.09 T h i n n e r s wh e r e v e r u s e d s h a l l b e t h o s e r e c o m m e n d e d b y t h e p a i n t manufacturers and shall be obtained in containers with manufacturer’s name and brand name of thinner legibly printed, failing which the thinner is liable to be rejected and shall not be used. 03.01.10 All paint containers shall be clearly labeled to show the paint identification, date of manufacture, batch number, special instruction, shelf life etc. The container shall be opened only at the time of use. 03.01.11 All paints shall be stored in accordance with the requirements of laid down procedure by the paint manufacturer. 03.01.12 All ingredients in a paint container shall be thoroughly mixed to break-up lumps and disperse pigments before use and during application to maintain homogeneity. The proposed make, quality and shade of the paint shall have the approval of the client. 03.01.13 03.01.14 The colour code of the finishing paint to be followed shall be intimated to the successful Tenderer after finalisaiton of order. The undercoat shall have different tint to distinguish the same from the finishing coat. 03.01.15 The Contractor shall furnish paint manufacturer’s test report or technical data sheet pertaining to the paint selected. The data sheet shall indicate a m o n g o t h e r t h i n g s t h e r e l e v a n t s t a n d a r d s , i f a n y, c o m p o s i t i o n i n we i g h t p e r c e n t o f p i g m e n t s , v e h i c l e s , a d d i t i v e s , d r y i n g t i m e , v i s c o s i t y, s p r e a d i n g rate, flash point, method of application, quality of surface preparation required, corrosion resistance properties and colour shades available. 03.01.16 For details of paint materials refer Annexure - 02 03.02 General 03.02.01 Each coat of paint shall be continuous, free of pores and of even film t h i c k n e s s wi t h o u t t h i n s p o t s . 03.02.02 Each coat of paint shall be sufficiently dr y before application of next coat. 03.02.03 Paint shall be applied at manufacturer’s recommended rates. The number of coats shall be such that the minimum dry film thickness specified is a c h i e v e d . T h e d r y f i l m t h i c k n e s s o f p a i n t e d s u r f a c e s s h a l l b e c h e c k e d wi t h ELCOMETER of measuring gauges to ensure application of specified DFT. © 2007 MECON Limited All rights reserved Painting Page 4 of 19 GS-09 General Technical Specification 03.02.04 Z i n c r i c h p r i m e r p a i n t s wh i c h h a v e b e e n e x p o s e d s e v e r a l m o n t h s b e f o r e finishing coat is applied shall be washed down thoroughly to remove soluble zinc salt deposits. 03.02.05 T h e m a c h i n e f i n i s h e d s u r f a c e s s h a l l b e c o a t e d w i t h wh i t e l e a d a n d t a l l o w before shipment or before being put out into the open air. 03.02.06 Areas which become inaccessible after assemble shall be painted before a s s e m b l y ( a f t e r o b t a i n i n g p a i n t i n g c l e a r a n c e f r om t h e i n s p e c t i n g a u t h o r i t y) after requisite surface cleaning as specified. 03.02.07 P a i n t s h a l l n o t b e a p p l i e d wh e n t h e a m b i e n t t e m p e r a t u r e i s 5 d e g C a n d below or 45 deg C and above. Also paint shall not be applied in rain, wind, fog or at relative humidity of 80 % and above unless the manufacturer’s recommendations permit. Applications of paint shall be o n l y b e s p r a yi n g o r b r u s h i n g a s p e r I S 4 8 6 – 1 9 8 3 a n d I S 4 8 7 – 1 9 8 5 . 03.02.08 Primer paint shall be applied not later than 2 – 3 hours after preparation of surface, unless specified otherwise. 03.02.09 Edges, corners, crevices, depressions, joints and welds shall receive special attention to ensure that they receive painting coats of the required thickness. 03.02.10 Surfaces which cannot be painted but require protection shall be given a coat of rust inhibitive grease according to IS 958 – 1975 or solvent deposited compound according to IS 1153 – 1975 or IS 1674 – 1960. 03.02.11 Surfaces in contact during shop assembly shall not be painted. Surfaces which will be inaccessible after assembly shall receive minimum two coats of specified primer. 03.02.12 Surfaces to be in contact with wood, brick or other masonr y shall be given one shop-coat of the specified primer. 03.03 Site/Field Painting 03.03.01 W herever shop primer painting is scratched, abraded or damaged, the surface shall be thoroughly cleaned using emery paper and power driven w i r e b r u s h w h e r e v e r wa r r a n t e d , a n d t o u c h e d u p w i t h c o r r e s p o n d i n g primer. Touching up paint shall be matched and blended to eliminate conspicuous marks. 03.03.02 If more than 50% of the painted surface of an item requires repair, the entire item shall be mechanically cleaned and new primer coats shall be applied followed by intermediate and finishing coats as per painting specification. 03.03.03 A l l f i e l d we l d e d a r e a s o n s h o p p a i n t e d i t e m s s h a l l b e m e c h a n i c a l l y cleaned (including the weld area proper, adjacent areas contaminated by w e l d s p a t t e r o r f u m e s a n d a r e a s wh e r e e x i s t i n g p r i m e r p a i n t i s b u r n t ) . © 2007 MECON Limited All rights reserved Painting Page 5 of 19 GS-09 General Technical Specification S u b s e q u e n t l y, n e w p r i m e r a n d f i n i s h i n g c o a t s o f p a i n t s h a l l b e a p p l i e d a s per painting specification. 03.03.04 T h e f i r s t c o a t o f f i n i s h p a i n t a t s i t e s h a l l b e a p p l i e d p r e f e r a b l e wi t h i n t h r e e months of the shop paint. 03.04 Structural 03.04.01 All fabricated steel structure, fabricated steel pipes, etc. shall have a m i n i m um o f t w o c o a t s o f p r i m e r p a i n t b e f o r e d i s p a t c h t o s i t e . 03.04.02 Parts of steel structures embedded in concrete shall be given a protective coat of Portland cement slurry immediately after fabrication and after s u r f a c e s o f t h i s p a r t i s t h o r o u g h l y c l e a n e d f r om g r e a s e , r u s t , m i l l s c a l e s , etc. No paint shall be applied on this part. 03.04.03 All structures shall receive appropriate number of primer and finishing coats in order to achieve overall DFT as per design drawings/specification. 03.05 Hot Surfaces 03.05.01 Total DFT for heat resistant paints should not exceed 100 – 120 microns, otherwise flaking occurs (as per paint manufacturer’s recommendations). 03.05.02 Heat resistant paints should be applied by brush. 03.05.03 Primer coat should not be applied on the surfaces having temperature condition more that 120 deg C. 04 P AI N T I N G S C H E M E S F o r a c o m p l e t e p a i n t i n g s c h e m e o f a n y i t e m b e i n g p r i n t e d , a l l t yp e s o f p a i n t s a r e t o b e p r o c u r e d f r o m t h e s a m e m an u f a c t u r e r a s a p p r o v e d b y t h e purchaser. 04.01 Legend SP 2P1 1I1 2F1 DFT CRT- Surface preparation quality as per SIS standard T wo ( 2 ) c o a t s o f P r i m e r p a i n t t yp e P 1 O n e ( 1 ) c o a t s o f I n t e r m e d i a t e p a i n t t yp e I 1 T wo ( 2 ) c o a t s o f F i n i s h p a i n t t yp e F 1 Dry Film Thickness in microns developed Clean and Retouch T yp e o f p a i n t p r o d u c t s l i k e P 1 t o P 9 , I 1 t o I 4 a n d F 1 t o F 1 0 h a v e b e e n specified under Annexure-02. 04.02 The painting scheme to be followed for various structure/equipment exposed to different condition is briefly given in Annexure-03 for guidance to the tenderer. © 2007 MECON Limited All rights reserved Painting Page 6 of 19 GS-09 General Technical Specification 04.03 The colour code for different applications are indicated in Annexure-04. W herever colour codes are not specified, the same is to be mutually agreed between the Purchaser and Contractor. 05. G U AR AN T E E 05.01 T h e C o n t r a c t o r s h a l l g u a r a n t e e t h a t t h e p h ys i c a l a n d c h e m i c a l p r o p e r t i e s of the paint materials conform with the specification of paint products. 05.02 The Contractor shall submit internal test reports from paint manufacturers regarding the quality of paint whenever asked by the Purchaser/Consultant. 05.03 Guarantee period shall commence from the date of completion of finishing coat of paint. The guarantee period will be indicated depending on the t yp e o f s u r f a c e p r e p a r a t i o n a n d s ys t e m o f p a i n t i n g . T o f u l f i l l t h i s obligations the Contractor may obtain from the painting manufacturer, guarantee for the performance of paint/painted surfaces. © 2007 MECON Limited All rights reserved Painting Page 7 of 19 GS-09 General Technical Specification Annexure-01 Surface Preparation Grade Sl. No. 1 Surface Preparation Blast cleaning to white metal Removal of all visible rusts, mill-scales, paint and foreign matters. 2 Sa 3 Sa 3 Sa 2.5 Sa 2.5 Sa 2 Sa 2 Sa 1 Sa 1 St 3 St 3 St 2 St 2 Blast cleaning to commercial quality: At least 2/3 of any section of the surface area is free from all rusts, mill-scales and visible residues. 4 DIN Std. Din 55928 (Part 4) Blast cleaning to near white metal: 95% of any section of surface area is free from all rusts, mill-scales and visible residues. 3 Swedish Std SIS 055900 Brush-off blast cleaning: Removal of all loose mill-scales, rust and foreign matters etc. 5 Power tool cleaning: Very thorough scrapping and wire brushing to remove loose mill-scale, rust and foreign matters to have pronounced metallic shine. 6 Hand tool cleaning: Removal by hand brushing of loose mill-scale, loose rust and foreign matters. © 2007 MECON Limited All rights reserved Painting Page 8 of 19 GS-09 General Technical Specification Annexure - 02 P AI N T M AT E R I AL S 01. P R I M E R P AI N T S ( P ) Primer paint products shall be applied only on dr y and clean surfaces. 01.01 P r i m e r P a i n t – P 1 ( P h e n o l i c – Al k y d B a s e d ) A s i n g l e p a c k a i r d r y i n g p h e n o l i c m o d i f i e d a l k yd c o m p o s i t i o n w i t h z i n c phosphate as a primer paint conforming generally to IS : 2074. Air drying time 01.02 - About 60 minutes (touch dry) - Overnight (hard dry) Dry film thickness (DFT)/Coat - 40 microns (min) Temperature resistance - Upto 100 C dry heat Primer Paint – P2 (Chlororubber Based) A single pack air phosphate primer. 01.03 0 d r yi n g high build chlorinated rubber based Percent chlororubber - 20 to 22 (% Chlorine above 65% in chlororubber) Air drying time - About 15 minutes (touch dry) Overnight (hard dry) DFT/ Coat - 50 microns (min) Temperature resistance - Up to 65 C dry heat zinc 0 Primer Paint – P3 (PVC Copolymer Alkyd Based) Polyvinyl chloride (PVC) - Alkyd zinc phosphate – redoxide based primer Ratio : PVC copolymer + alkyd resin (1:1) Pigments : Zinc phosphate & Fillers Air drying time - 24 hours DFT/Coat - 80 microns Temperature resistance - Upto 80 C dry heat © 2007 MECON Limited All rights reserved Painting Page 9 of 19 0 GS-09 General Technical Specification 01.04 Primer Paint – P4 (Epoxy Based) A t w o p a c k a i r d r yi n g E p o x y p o l ya m i d e r e s i n b a s e d r e d o x i d e - z i n c phosphate primer. 01.05 Epoxy content (% wt.) - 15 to 18 Air drying time - About 30 minutes (touch dry) overnight (hard dry) DFT/Coat - 30 microns (min) Temperature resistance - Upto 120 C dry heat 0 Primer Paint – P5 (Epoxy Based) A t w o p a c k a i r d r yi n g E p o x y p o l ya m i d e w i t h zi n c d u s t o f a t l e a s t 9 2 % z i n c dust on the dr y film 01.06 Epoxy content (% wt.) - 8 to 10 Air drying time - Less than 10 minutes (touch dry) Less than 2 hours (hard dry) DFT/Coat - 40 microns (min) Temperature resistance - Upto 300 C dry heat 0 Primer Paint – P6 (Poly – Vinyl Butyral Resin Based) A t w o p a c k a i r d r yi n g p o l yv i n yl b u t yr a l r e s i n b a s e d w a s h p r i m e r w i t h r u s t inhibitive pigments. 01.07 Air drying time - 5 to 7 minutes (touch dry) 2 hours (hard dry) DFT/Coat - 8 microns Temperature resistance - Upto 65 C dry heat Application for - Galvanised iron, aluminium, light alloys etc. on which the adhesion of conventional paints are poor. 0 Primer Paint – P7 (Ethyl Zinc Silicate, EZS Based). A t wo p a c k h e a v y d u t y z i n c d u s t r i c h s i l i c a t e p r i m e r wh i c h p r o t e c t s t h e surface with just a single coat. T ota l s o l i ds ( 3 wt) De ns it y ( g / c c ) © 2007 MECON Limited All rights reserved - 84 +/- 2 3. 0 7 + /- 0. 0 5 Painting Page 10 of 19 GS-09 General Technical Specification A ir dr yi n g t im e DF T / c o at T em per at ur e r es is t a nc e 01 . 08 - T o t op c o a t 16 ho ur s 60 m ic r o ns Up to 45 0 d eg C dr y h e at P ri m e r P a in t – P8 ( H i g h B u i ld Co al T a r Ep o x y) A t wo p ac k c o l d c ur ed H. B. ep ox y c o a l tar c o at i ng – no pr im er is r e qu ir e d. 01 . 09 M ix i n g r a ti o A ir dr yi n g t im e - DF T / C oa t - B as e : Ha r d e ner ( 4: 1b y v o l .) 48 ho ur s ( h ar d dr y) F u l l c ur e 7 d a ys 10 0 m ic r o ns W o o d V a rn i sh - P 9 T r eat e d o il bas e d pr im er p igm e nt ed wi th s u it ab l e p i gm ents : 02 . A ir dr yi n g t im e - 16 ho ur s f or a pp l ic at i o n of to p c o at . Co v er ag e - 10 t o 1 4 s q . m /l it r e INT E RM EDI AT E P AI N T S ( I) T hes e p a in ts s ha l l be ap p l ie d o v er p r im er c o ats as an i n ter m ed i a te l a yer t o pr o v i d e we a th er pr o of s ea l of pr im er c oa ts . 02 . 01 In t er m e d i at e P ain t - I I ( P h e n o l i c al k yd b a s e d ) A s i n g le p ac k hi g h b u il d p h en o l ic b as e d p a in t wit h m ic ac e o us i r on ox id e ( M 10) . A ir Dr yi n g T im e 2 d a ys ( ha r d d r y) DF T /C o at T em per at ur e r es is t a nc e Com pa t ib l e wi t h 02 . 02 - 4 to 6h o ur s ( to uc h dr y) - 7 5 m ic r ons ( m in) Up to 10 0 d eg C d r y h e at P r im er P 1 - In t er m e d i at e P ain t - I 2 ( Ch lo ro ru b b e r b a s ed ) A s i n gl e p ac k a ir dr yi n g h ig h b u i ld c h l or o b a s ed pa i nt wi th MIO . A ir Dr yi n g T im e DF T /C oa t T em per at ur e r es is t a nc e Com pa t ib l e wi t h 02 . 03 - 1 5 m i nu t es ( to uc h dr y) 24 ho ur s ( h ar d dr y) 70 m ic r o ns ( m i n ) U pt o 6 5 d eg C d r y h e at P r im er P 2, P 3 & P 4 In t er m e d i at e P ain t - I 3 ( P V C – Al k yd B a se d ) P VC C op l o ym er P igm e nts DF T /C oa t © 2007 MECON Limited All rights reserved - Res i n 1 : 1 M ic ac e ous ir o n ox i d e ( MIO ) 80 m ic r o ns ( m i n) Painting Page 11 of 19 GS-09 General Technical Specification T em per at ur e r es is t a nc e Com pa t ib l e wi t h 02 . 04 - Up to 80 d e g C dr y h e a t Pr im er P2 & P 3 In t er m e d i at e p ai n t - I 4 A t wo p ac k a ir dr yi n g h ig h b u il d e p ox y r es in bas e d p ai n t wi t h MI O . A ir dr yi n g t im e DF T / c o at T em per at ur e r es is t a nc e Com pa t ib l e wi t h 03. - 6 to 8 ho ur s ( t o uc h d r y) 7 d a ys ( f u l l c ur e) 10 0 m ic r o ns 0 Up t o 1 80 C dr y h ea t Pr im er P4 & P 5 F I N I S H P AI N T S ( F ) Finish paint costs shall be applied over primer coats and intermediate coats after proper cleaning and touch up of primed surface. 03.01 Finish Paint – F1 A s i n g l e p a c k a i r d r y i n g h i g h g l o s s p h e n o l i c a l k yd m o d i f i e d s yn t h e t i c enamel paint suitably pigmented. 03.02 Air drying time - 3 to 4 hours (touch dry) 24 hours (hard dry) DFT/Coat - 25 microns (min) Temperature resistance - Upto 100 C dry heat Compatible with - Colour - Primer P1 Intermediate I1 Generally all shades 0 Finish Paint – F2 A s i n g l e p a c k a i r d r yi n g p o l yu r e t h a n e e n a m e l o f h i g h g l o s s a n d h a r d f i n i s h suitably pigmented. Air drying time - 2 to 2 ½ hours (touch dry) 6 hours (hard dry) DFT/Coat - 30 microns (min) Temperature resistance - Upto 100 C dry heat Compatible with - Colour - Primer P1 & P8 and Intermediate I1 Generally all shades © 2007 MECON Limited All rights reserved 0 Painting Page 12 of 19 GS-09 General Technical Specification 03.03 Finish Paint – F3 A t w o p a c k a i r d r yi n g b i t u m i n o u s a l u m i n u m p a i n t . 03.04 Air drying time - 1 to 2 hours (touch dry) 21 hours (hard dry) DFT/Coat - 25 microns (min) Temperature resistance - Upto 100 C dry heat Compatible with - Primer P1 and Intermediate I1 Colour - Bright metallic 0 Finish Paint – F4 A r e a d y m i x e d o i l - a l k yd b a s e d s yn t h e t i c e n a m e l p a i n t o f h i g h g l o s s a n d hard wearing properties. 03.05 Air drying time - 6 to 8 hours Coverage - 14 to 16 Sq. m /litre Temperature resistance - Upto 60 C dry heat Compatible with - P8 Colour - Generally all shades 0 Finish Paint – F5 A s i n g l e p a c k a i r d r yi n g p l a s t i c i z e d c h l o r o r u b b e r p a i n t s u i t a b l y p i g m e n t e d . Air drying time - 30 minutes (touch dry) 24 hours (hard dry) DFT/Coat - 35 microns (min) Temperature resistance - Upto 65 C dry heat Compatible with - Colour - Primer P2 & P3, Intermediate I2 & I3 Nearly all shades except few. © 2007 MECON Limited All rights reserved 0 Painting Page 13 of 19 GS-09 General Technical Specification 03.06 Finish Paint – F6 A P V C – C o p o l ym e r a l k yd b a s e d e n a m e l . 03.07 Density - 1.17 + 0.05 Total solids (1 wt) - 55 + 2 DFT/Coat - 40 microns Compatible with - P2 and P3 Finish Paint – F7 A t w o p a c k a i r d r yi n g e p o x y p o l ya m i d e e n a m e l s u i t a b l y p i g m e n t e d . 03.08 Air drying time - 2 to 3 hours (touch dry) 7 days (full cure) DFT/Coat - 40 microns (min) Temperature resistance - Up to 130 C dry heat Compatible with - Primer P4 & P5, Intermediate I4 Colour - Generally all shades. 0 Finish Paint – F8 A s i n g l e p a c k s yn t h e t i c r u b b e r b a s e d a l u m i n i u m p a i n t . Air drying time - 2 hours (touch dry) 24 hours (hard dry) DFT/Coat - 25 microns (min) Temperature resistance - Upto 200 C dry heat Compatible with - No Primer paint except primer P6 is applicable in case of non-ferrous substrate. Colour - Smooth aluminium. © 2007 MECON Limited All rights reserved 0 Painting Page 14 of 19 GS-09 General Technical Specification Annexure - 03 PAINTING SCHEME Sl. No. 1.0 1.1 1.2 Painting Scheme At Shop At Site Description Steel Structures 0 (Temp. not exceeding 80 C) Technological steel structures for plant and equipment Indoor SP – Sa 2.5 2P1 CRT 2F1 130 Outdoor SP – Sa 2.5 2P1 1I1 CRT 2F1 205 SP – St-2 and/ or St-3 2P1 CRT Fabricated steel structures at site for rung ladders, cat-ladders, gates, rolling shutters, etc. (Springs/rubbing surfaces excluded) - Indoor / Outdoor 1.3 SP – St-2 and/ or St-3 2P1 - Outdoor SP- St2 and/ or St-3 2P1 1I1 130 CRT 2F1 130 CRT 2F1 205 Steel doors and windows - Indoor / outdoor Sl. No. 2.0 2F1 Walkways, stairs, platforms etc. which are of wearing surface - Indoor 1.4 Total DFT (Refer Note-1) SP–St-2 and / or St-3 2P1 1I1 2F2 Painting Scheme At Shop At Site Description MECHANICAL EQUIPMENT 2.1 Mechanical equipment 0 (Temp. not exceeding 80 C) 2.1.1 Static equipment like storage tanks, vessels, bins, bunkers, heat exchangers, coolers, © 2007 MECON Limited All rights reserved CRT Painting Page 15 of 19 215 Total DFT GS-09 General Technical Specification Sl. No. Painting Scheme At Shop At Site Description cyclones, scrubbers, etc. 2.1.2 Sl. No. 3.0 3.1 - Indoor SP – Sa 2.5 2P2/2P3 CRT 2F5/2F6 170/240 - Outdoor SP – Sa 2.5 2P2/2P3+1I2/1I3 CRT 2F5/2F6 240/320 - Indoor SP – Sa 2.5 2P3/2P4 CRT 2F6/2F7 240/140 - Outdoor SP-Sa 2.5 2P3 + 1I3/1I4 CRT 2F6/2F7 320/340 Rotary/moving equipment and machineries like crushers, mills, vibratory screens, bin activators, blowers, fan, air/gas compressors, pumps, gear boxes, machine housings etc. Painting Scheme At Shop At Site Description Pipe / Duct work (Overground) SP – St2 and or St3 2P1 SP – St2 and / or St3 2P1 + 1I1 - Outdoor Insulated (hot) - Indoor/Outdoor SP- St2 and/ or St3 1P1 Sl. No. 4.0 4.1 Total DFT Non – insulated 0 (temperature up to 80 C) - Indoor 3.2 Total DFT Oxygen Plant © 2007 MECON Limited All rights reserved 2F1 CRT 130 2F1 205 Remove paint and insulate Painting Scheme At Shop At Site Description Outdoor steel structures CRT SP – St2 and / or St3 Painting Page 16 of 19 Total DFT CRT GS-09 General Technical Specification Sl. No. Description 4.2 Rotary equipment like air compressors 5.0 Others 5.1 Standard mobile equipment like chasis of trucks, dumpers, crawler cranes bulldozers, railway rakes, chasis of slag cars, ladle cars, etc. Laboratory equipment like ovens, screens, magnetic stirrers, samplers, etc. Steel structures partly immersed in water 5.2 5.3 Painting Scheme At Shop At Site 2P1 + 1I1 2F3 Sa 2.5 CRT 2P4 2F7 Total DFT 205 140 As per manufacturer’s standards Stove enamelling CRT SP – Sa 2.5 CRT 2P8 110 200 Notes: 1. Painting scheme of all fabricated steel structures, fabricated pipe work, building s t r u c t u r e , c o n v e yo r g a l l e r i e s , p i p e t r e s t l e s e t c . i s i n d i c a t e d i n t h e T e c h n i c a l Specification of steel structures. 2. Primer Paint Primer coat shall be suitable for intended temperature applications as per manufacturer’s recommendation. The primer selection shall be generally in line with the specification laid down in Annexure-02. 3. Finish Paint I n c a s e o f A l u m i n i u m c l a d d i n g f i n a l p a i n t i n g wi l l n o t b e r e q u i r e d . © 2007 MECON Limited All rights reserved Painting Page 17 of 19 GS-09 General Technical Specification ANNEXURE - 04 COLOUR CODE The colour codes are mentioned for all the items including pipe work. Shades of finish coat of paint applied over respective item indicated below are tentative and subject to alteration as per Purchaser’s request or due to compatible paint system adopted. The service for which colour code/bands are not specified are to be mutully agreed for by the Purchaser & the Contractor. Sl. No. 1. 2. Items Painted Structures Building frames including bracings, side girts, louvers etc. Crane girders Crane stops Gutters Fire escape platforms ladders, etc. General hand railing, top runners Rung ladders All members blocking passages for movement Trestles, towers and pipe bridges Conveyor gallery structures Steel chimneys Equipment and Machinery General indoor equipment General outdoor equipment Crane bridges, trolleys, hooks etc. and other mobile equipment Furnaces Tanks Fire-fighting equipment 3. Colour Colour No. of IS:5 Aircraft grey 693 Azure blue Post office red Black bituminous aluminium Signal red Lemon yellow Lemon yellow Lemon yellow 104 538 537 355 355 355 Dark admiralty grey Aircraft grey Aluminium 632 693 - Light grey Dark admiralty Base : Lemon yellow Stripes : Black (100 mm wide) Aluminium Base : Same as for general equipment Strips : Same shade as for piping around the tnk at half the tank height Signal red 631 632 355 537 Pipe work Colours shall be as given below. The base colour shall be applied throughout entire length except on surfaces of materials such as asbestos, aluminium, brass, bronze, galvanized steel, stainless steel and other corrosion resistant alloys and rubber / synthetic polymers. In such cases identification colour bands of at least 500mm width shall be provided near each branch, valve and at distances not exceeding 10m either as local colour coatings or coloured adhesive type of suitable material or label attached to the pipe work. Additional identification bands superimposed over the base colour shall be provided near each branch, valve and at distance not exceeding 10m. The bands shall be atleast 25mm wide except in care of double bands where the first band shall be about 100mm wide. Direction of flow shall be clearly marked on the pipelines at intervals not exceeding 10m and all branches and change of directions. © 2007 MECON Limited All rights reserved Painting Page 18 of 19 GS-09 General Technical Specification Service Sea or river water (untreated) Cooling water Boiler feed water Condensate Drinking water Industrial water Compressed air Instrument air Drainage Fuel oil Coke oven/BF gas/other fuel gases Argon Acetylene LP Gas (LPG) Nitrogen Oxygen Non-acidic slurries Fire-fighting system Rain water down pipes Duct work Colour Base – Sea green Band - White Base – Sea green Band - White Base – Sea green Base – Sea green Band – Light brown Base – Sea green First band - French blue Second band – Signal red Base – Sea green Band – Light orange Base – Sky blue Base – Sky blue Band – Light brown Base – Black Base – Light brown Band – Signal red Base – Canary yellow Band – Signal red Base – Canary yellow Band – French blue Base – Canary yellow Band – Dark violet Base – Canary yellow First band – Signal read Second band – Traffic green Base – Canary yellow Band – Black Base – Canary yellow Band – White Base – Sea green Band – White Base – Signal red Base – Sea green Band – Sky blue Base – Aluminium 217 217 166 217 217 410 217 166 537 217 557 101 101 410 410 537 309 537 309 166 309 796 309 537 267 Colour No. of IS:5 309 309 217 537 217 101 - Note : For these services, hazard marking as per fig. 4C of IS:2379 shall also be provided. © 2007 MECON Limited All rights reserved Painting Page 19 of 19 GS-09