KARNATAKA POWER TRANSMISSION CORPORATION LIMITED Corporate Office, Kaveri Bhavan, Bangalore - 560 009. No. B19/7625/86-87 Encl: Dated: � 1 APR 2013 To, All The ChiefEngineers (Electricity), Transmission Zones, KPTCL, Bangalore/Mysore/Tumkur/Hassan/Bagalkot/Gulbarga, The ChiefEngineers (Electricity), P&C, T&P, TA&QC, RT and R&D, KPTCL. Sir, Sub:- Revision of Major Works Schedule of Rates as per the recommendations of S.R. Revision Committee and as per the approval of Central Purchase Committee - reg. Ref:- 1. KPTCL Order of even No. Dt. 18.02.2012- Constitution of Committee for revision of Major Works Schedule of Rates. 2. Discussions held on 21 &22.03.2013 in the 131 st T&P Central Purchase Committee meeting. The Major Works Schedule of Rates has been revised with effect from 01.04.2013. As such, the revised S.R will be in force from 01.04.2013 till further orders. The copy of the revised SR is notified in the KPTCL website for information and use of all the officers of KPTCL for its effective implementation with immediate effect. The estimates I DPRs prepared from 01.04.2013 shall be based on the revised S.R without fail. You are hereby directed to instruct all your sub-ordinate offices I officials in the matter. The booklets of the Major Works S.R shall be made avail�ble to all offices in due course. Yours faithfully 9,,9.l 11�ot.o4.,f� Deputy General Manager (Tech.), Copy to: KPTCL, Bangalore. The Financial Adviser (A&R) I (I/A), KPTCL, Bangalore All Superintending Engineers Works I Works &Maintenance Circles, KPTCL All Controller of Accounts, Transmission Zones, KPTCL. All Executive Engineers, Electy., Major Works/TL&SS Divisions, KPTCL Copy for information to: PS to Managing Director I Director (Transmission) I Director (Finance) I Director(RA)& Secretary, KPTCL to bring to the notice of the Directors for information. � T�uperintending Engineers (Elec.,) IT&MIS with a request to upload the revised S.R on the '�PTCL website. . KPTCL MAJOR WORKS SCHEDULE OF RATES WITH EFFECT FROM 01.04.2013 INDEX SI. No. Description Page Nos. 1 Part-1 : Material Portion 01-44 2 Part-2 : Labour Portion 45-81 3 Part-3 : Transformer Repairs 82-84 PART-I RATES FOR MAJOR WORKS MATERIALS/EQUIPMENTS SI. No. 1 Description of Materials Unit Amount in Lakhs. A POWER TRANSFORMERS: 1 2 3 150 MVA, 3 Ph 220/66/ l lkV , Oil forced cooling, complete with all fitting and accessories,OLTC, RTCC, FCC, first filling of oil and 10% spare oil in non-returnable drums. lOOMVA, 220/66 / 1 1 kV Transformer complete with accessories as in item No. 1 above lOOMVA, 220/ 1 10/ 1 1 kV Auto transformer complete with accessories as in item No. 1 above No. 648.01 No. 529.97 No. 343.55 4 31.5 MVA, 66/ 1 1 kV Transformer complete with accessories as in item No. 1 above No. 172.03 5 16/20 MVA, 66/ 1 1 kV Transformers complete with all fittings and accessories, OLTC, RTCC first filling of oil and 10% snare Oil No. 136.30 6 20 MVA, 1 10/33/ 1 lkV Transformer with accessories as in item No. 5. No. 134.80 7 12.5 MVA, 66/ l lkV Transformer with accessories as in item No. 5. No. 1 1 1.23 8 10 MVA 1 10/33/ l lkV Transformer with accessories as in item No.5 No. 95.79 9 8 MVA 66/ 1 1 kV Transformer with accessories as in item No. 5 No. 73.31 10 EHV Grade Transformer oil in new steel barrels of 2 101itres capacity strictly confirming to IS 335/ 1993 kL 0.89 B I) EHV CIRCUIT BREAKERS: 1 220 kV No. 14.47 2 l lO kV No. 6.16 3 66 kV No. 5.38 4 33 kV No. 2.69 Incomer Panel No. 4.65 Feeder Panel No. 3.66 Feeder Panel for capacitor bank No. 4.02 , II) 11 kV SWITCH GEAR A 1 lKV PCVCB, 350MVA, 20KA, 1250A incomer 800A feeder Rs SI. No. B c D Description of Materials Unit Amount in Rs Lakhs. l lKV MCVCB, 3SOMVA, 20KA, 12SOA incomer SOOA feeder Incomer Panel No. S.S9 Feeder Panel No. S. lS Bus Coupler No. S.02 Feeder Panel for capacitor bank No. S.4S Incomer Panel No. 6.00 Feeder Panel No. S.24 Bus Coupler No. S. lS Feeder Panel for capacitor bank No. s.ss Incomer Panel No. 7.62 Feeder Panel No. 6.19 Bus Coupler No. 6.77 Capacitor panel No. 6.S4 Adapter Panel ( 12SOA) No. 1.1 Adapter Panel (2000A) No. 1.2S 11/c + 4F No. O.S6 11/c + SF No. 1.11 21/c + SF No. 1.SS 11/c + 4F + lCB No. 1.02 11/c + SF + lCB No. 1.26 21/c + SF + 2CB No. 1.S6 21/c + SF + lBC No. 1.69 l lKV MCVCB, SOOMVA, 2SKA, 1600A incomer 12SOA feeder l lKV MCVCB, SOOMVA, 3 1 .SKA, 2000A incomer 1600A feeder E Adapter Panel for MCVCB F Annunciator Panel for the following combinations (Both for MCVCB & PCVCB) 000002 1i -· Sl. No. c Description of Materials Unit Amount in 2I/c + lOF + lBC No. 1.86 2I/c + 12F + lBC No. 2.03 2I/c + 14F + lBC No. 2.2 2I/c + 16F + lBC No. 2.52 CURRENT TRANSFORMERS with 0.2 accuracy class: 1 220 kV Class Nos. 3.23 2 1 10 kV Class - 600-400 / l- 1 - lA (for lOOMVA Tr.) Nos. 1.41 3 l lOkV Class 400-200/ 1-l-lA Nos. 1.14 4 1 10 kV Class - 200- 100/ l-l-lA Nos. 1. 14 5 66kV Class 1600-1000/ 1-1-lA Nos. 1.19 6 66 kV Class - 1000-800-600/ l-l-lA Nos. 1.19 7 66 kV Class - 400-200/ 1- l-lA Nos. 0.78 8 66 kV Class - 200-100/ 1-1- lA Nos. 0.78 9 33 kV Class 400-200/ l-l-lA Nos. 0.23 10 33kV Class 200- 100/ l-1-lA Nos. 0.23 1 1 1 1 kV NCTs 2000- 1200/ 1-1- lA(for 31.5kA SWG) Nos. 0.26 12 l lkV NCTs 1200-800/ 1-1-lA ( for 500MVA SWG) Nos. 0.23 13 l lkV NCTs 800-400/ 1-1-lA (for 350MVA SWG ) Nos. 0.23 Nos. 0.23 Nos. 0.26 Nos. 0.23 Nos. 0.23 Nos. 0.23 Nos. 0.23 Nos. 0.23 14 Rs Lakhs. l lkV NCTs 600-300/ l-1-lA ( for PCVCBs upto lOMVA transformer) 15 1 lkV CTs of ratios 1 1 kV CTs 2000- 1200/ 1-1- lA(for Incommer/Bus coupler for 3 1 .5kA SWG) l lkV CTs 1200-800/ l - l- lA ( for Incomer/Bus coupler for ii 500MVA SWGl l lkV CTs 800-400/ 1-1-lA (for Incomer/Bus coupler for iii 350MVA SWG ) l lkV CTs 600-400/ 1-1-lA ( for for feeders of 3 1.5 kA iv SWG) l lkV CTs 400-200/ 1-1-lA ( for for feeders of 500MVA v SWG) i vi l lkV CTs 200- 100/ 1-l-lA ( for feeders of 350MVA SWG) D CAPACITOR VOLTAGE TRANSFORMERS: 000003 SI. Amount in Description of Materials Unit 1 245kV CVT, 8800 PF, one phase CVT with 3 secondaries. Nos. 3.28 2 245kV CVT, 4400 PF, one phase CVT with 3 secondaries. Nos. 2.88 No. Lakhs. E VOLTAGE TRANSFORMERS: 1 22okv1v31 1 1ov..J3 / 1 1ov v3 - 1 1ov / ..J3 Nos. 2.48 2 3 l lOkV / v3/ 1 10V/ v3 - 1 10V/ v3-1 10Vv3 66kV/ v3 / uov/ v3- 1 1ov/ v3 -uov/'13 Nos. Nos. 1.19 0.78 4 33kV/ v3 I 1 lOV / v3-l 10V / v3 Nos. 0.28 Nos. 0.24 5 l lkV / l lOV-l lOV (THREE PHASE) F LIGHTNING ARRESTORS (POLYMERIC): 1 198 kV Metal Oxide type, with surge counter (Discharge Class - 3) Nos. 0.43 2 96 kV Heavy Duty Metal oxide (Discharge Class - 2 for lines & Transformers) Nos. 0.34 3 60 kV 10 KA Normal Duty (Discharge Class -2 ) Nos. 0.15 4 30 kV Normal Duty Metal oxide (Discharge class -2 ) Nos. 0.087 5 96 kV Heavy Duty Metal Oxide (Discharge Class -3 for Capacitor bank ) Nos. 0.34 6 60 kV Normal Duty Metal Oxide (Discharge Class -3 ) Nos. 0.15 Nos. 0.07 7 30 kV Normal Duty Metal Oxide (Discharge Class -3 ) G ISOLATORS: 1 220 kV, 1250 A, 3 1.5 KA/40 KA for three seconds short time current rating remote, electrically cum manually operated double break type Disconnects with Solid core insulators: a Uurie:ht with Earth Switch LPH 5750 mm. Set 2.71 b Upright without Earth Switch (live point height 5750 mm) Set 2.34 c Upright without Earth Switch (live point height 8250 mm) Set 2.44 d Underhung without Earth Switch ( 12850 mm Mounting heie:ht) Set 2.65 2 l lOkV, 1250 A, 3 1.5 KA double break Electrically cum manually operated isolators as detailed in item No. 1: a Upright with Earth Switch LPH 4600 mm. Set 1.92 b Upright without Earth Switch( live point height 4600mm) Set 1.77 �-a."age,(;; �� � �· � i ,.,... c:: l���J ?l � . � eiY 'O�K�":'· ...... ,,. .. ooooo.4 Rs Sl. Description of Materials No. c Upright without Earth Switch( live point height 6350mm) Unit Amount in Rs Lakhs Set 1.77 Set 1.96 a Upright with Earth Switch LPH 4600 mm. Set 1.87 b Upright without Earth Switch( live point height 4600mm) Set 1.72 c Upright without Earth Switch( live point height 6350mm) Set 1.72 d Underhung without Earth Switch (10000 mm Mounting heie:ht) Set 1.91 4 66 kV, 1250A/800A, 3 1.5KA double break Electrically cum Manually operated isolators as detailed in item 1 : a Upright with Earth Switch LPH 4250 mm. Set 1.51 b Upright without Earth Switch (live point height 4250mm) Set 1.2 c Upright without Earth Switch (live point height 5500mm) Set 1.14 d Underhung without Earth Switch 66 kV, 1250A/800A, 3 1.5KA double break Manually 5 operated isolators as detailed in item 1: a Uprie:ht with Earth Switch LPH 4250 mm. Set 1.24 Set 1.46 Upright without Earth Switch (live point height 4250mm) Set 1 . 15 c Upright without Earth Switch (live point height 5500mm) Set 1.09 d Underhune: without Earth Switch 66 kV, 2000A, 3 1.5KA double break Electrically cum 6 Manuallv operated as detailed in item 1: Set 1. 19 Set 1.47 b Upright without Earth Switch 4250mm Set 1.50 c Upright without Earth Switch 5500mm Set 1.54 d Underhung without Earth Switch Set 1.47 Set 0.58 Set 0.49 Set 0.57 Underhung without Earth Switch ( 10000 mm Mounting heil(ht) l lOkV, 1250 A, 3 1.5 KA double break Manually operated isloators as detailed in item No. 1 : d 3 b Upright with Earth Switch a 33kV Isolators with electrically cum motor operating mechanism 7 33 kV, 800 A, 25 KA Upright with Earth Switch complete metallic portion with insulator 33 kV, 800 A, 25 KA Upright without Earth Switch (live b I point heil(ht 3750mm) 33 kV, 800 A, 25 KA Upright without Earth Switch (live c 'Point heie:ht 4750mm) a � �<onage, (;>; � . 6lc =?: � �-= � I(!) �f o� '• � Ob � c,'v 000005 SI. No. Description of Materials 33 kV, Isolators: 33 kV, 800 A, 25 KA Upright with Earth Switch complete a metallic portion with insulator 33 kV, 800 A, 25 KA Upright without Earth Switch (live b 'Point heil!:ht 3750mm) 33 kV, 800 A, 25 KA Upright without Earth Switch (live c 'Point heil!:ht 4750mm) H BATTERY SETS : l)Tubular tv'Pe: i 48 V. 200 AH ii Unit Amount in Lakhs 8 Set 0.53 Set 0.44 Set 0.60 Set 0.73 Set 1.45 l lOV, lOOAH Set 2.50 ii 220V, 300AH Set 15.44 I i 1 10 V, 100 AH (with float cum boost battery charger working on 230 V 1 Ph AC supply as per specifications). Set 0.96 Set 0.93 2 x 220V, 300 AH (with mains and standby float and boost iii battery charger working on 415V 3 Ph AC supply as per specifications). Set 4.66 Nos. 0.33 AC distribution Box Double front (outdoor type) 24 ii Terminal 1200x1350x600mm, two l/C of lOOAmps MCCB 20kA + 24 O/G MCB 16 Amps + 2 O/G of lOOA, HRC fuse Nos. 0.76 LTAC panel(indoor), 4 1 5V as per technical specification compraising of voltmeter and ammeter, 2 l/C ACB 800A+2 iii O/G SFU, 200A + 8 O/G SFU 100A+l40/G SFU, 63A+l2 O/G, 32A+lB/C SFU, 800A+lDG Change over switch 300A etc. Nos. 6.96 DC distribution panel (Indoor) 11/C SFU-200 A + 10 O/G iv SFU 63A+l0 O/G SFU 32A with relays for DC failure & DC Bus earth fault as per Techincal Specification Nos. 1.11 Nos. 0.45 l lO V, lOO AH II) Plante Tv'Pe: i ii J I i BATTERY CHARGER: 48 V, 200 AH LTAC Panels and ACDBs For 400 kV and 220 kV stations: AC distribution Box Single front (outdoor type) 6 Terminal 1200x1350x300mm, one l/C of lOOAmps MCCB 20kA + 6 O/G MCB 16 Amps + 1 O/G of lOOA, HRC fuse II For l lOkV and 66kV stations: i AC distribution Box Single front (outdoor type) 6 Terminal 1200x1350x300mm, one l/C of lOOAmps MCCB 20kA + 6 O/G MCB 16 Amps + 1 O/G of lOOA, HRC fuse ��:a:nager(;; � '9� g :]?.. j �h� <!> � ?"l' o'• o._.. � � �'lo £ -:::::: · i• 'V, c"":to o�� -- OOOOOb Rs Sl. Description of Materials No. Unit Amount in Lakhs. LTAC panel(indoor), 415V as per technical specification compraising of voltmeter and ammeter, 11/C MCCB ii 200A+2 Nos. 3-Phase 63A O/G SFU, + 2 Nos. 3-Phase 32A O/G SFU 100A+140/G SFU, 6 Nos. 3-Phase 16A SFU etc. comnlete Nos. 1.13 DC distribution panel (Indoor) as per technical specification comprising of earth fault indicator,iri.dication iii circuit for AC mains failure, 1 No lOOA SFU for I/C+12 Nos 32A SFU for 0/G Nos. 0.75 CAPACITOR BANK with 0.2 % Series reactor & NCT: DesignEngineering supply erection testing & commissioning of Capacitor Banks with internal fuses, terminal connector suitable capacity Neutral CTs, & 0.2% K series reactors on neutral side with elevating/ mounting structure and with 10% spare capacitors complete. (This does not include breaker, panel, civil works like excavation and foundation concreting works) i 123kV 24 MVAR (Double star, double Bank of 4x6 MVAR) Set 25.76 ii 123 kV, 20 MVAR (Double star, double bank of 4x5 MVAR) Set 2 1.46 Set 2 1.01 Set 20.79 Set 25. 12 vi 12. lkV 2.9 MVAR star connected Capacitor bank Set 3.43 vii 12. lkV 5.8 MVAR star connected Capacitor bank Set 6. 13 viii 12. lkV 2.5MVAR star connected Capacitor bank Set 3.83 Km 0.66 ii 2 Core 6 sq.mm Km 1.17 iii 4 Core 2.5 sq.mm Km 0.99 iv 4 Core 6 sq.mm Km 1.97 10 Core 2.5 sq.mm Km 2. 18 vi 14 Core 2.5 sq.mm Km 2.91 vii 19 Core 2.5 sq.mm Km 3.82 viii 4 Core 4 sq.mm Km 1.39 Km 1.03 123kV 24 MVAR (Double star connected Bank of 2x12 MVAR) 72.5kV 20MVAR (Double star connected Bank of iv 4x5MVARl 72.5kV 20 MVAR (Double star connected Bank of 2xl0 v MVARl iii Copper Control Cables: L 2 Core 2.5 sq.mm i v ix 2 Core 10 sq.mm �;,�a\Ma� � 0qj � � I�� !!>£. '� \• Cl �, *.f..... ·l-?T.cl.. .. .::, g· \'S * ·- .ooooor Rs SI. No. Description of Materials Unit Amount in Rs Lakhs. 4 Core 10 sq.mm Km 3.06 xi 4 Core 16 sq.mm Km 4.47 xii 4 Core 25 sq.mm Km 3.57 xiii 2 Core 150 sq.mm Km 20.38 x M 1. lkV class Armoured Aluminium Cables: a 4x240 sqmm Aluminium,cable with glands/lugs/ferrules Km 7.92 b 4x95 sqmm Aluminium,cable with glands/lugs/ferrules Km 3.34 c 4x70 sqmm Aluminium,cable with glands/lugs/ferrules Km 3.34 d 4x25 sqmm Aluminium,cable with glands/lugs/ferrules Km 1.08 No 5.19 ii 66kV line panel No 5.06 iii 1 10/33kV Tr. panel No 6.5 iv 1 10/ l lkV Tr. panel No 6.5 No 5.23 vi 33kV line panel No 2.43 vii 1 lkV capacitor Bank panel No 3.9 1 C&R Panels compatible to SCADA for installation in 220kV sub stations: i 220 kV line panel - Type 2L ii 220/66/ 1 1 kV Transformer panel- Tvpe 2T6 Nos. Nos. 10.73 20.07 iii 220/ 1 10/ 1 1 kV Transformer panel - Type 2Tl Nos. 20.22 iv 220 kV Bus Coupler panel - Type 2BC Nos. 5.55 Nos. 24.5 vi 1 10 kV line panel - Type lL Nos. 8.37 vii 1 10 kV Bus Coupler panel - Type lBC Nos. 4.97 viii 1 10/ 1 1 kV Transformer panel - Type lTl Nos. 16.01 Nos. 10. 14 66 kV Bus Coupler panel - Type 6BC Nos. 4.97 xi 66/ 1 1 kV Transformer panel - Type 6Tl Nos. 15.80 C&R Panels compatible to IEC6 1850, communication c protocol for station automation system in 220kV sub stations: i 220 kV line Type 2Llas per annexure RPPI-SAS) Nos. 10.73 CONTROL AND RELAY PANELS: 1 10kV/66kV/33kV Stn.- Simplex l lOV DC compatible to A SCADA 2 A i v l lOkV line panel 66/ l l kV Tr. panel B v 220 kV Bus Bar Protection panel - Type 2BBA ix 66 kV line panel - Type 6L x 000008 g I 81. No. Description of Materials 220/66/ 1 1 kV Transformer Type 2T6(as per annexure RPPI-SASl 220/ 1 10/ 1 1 kV Transformer Type 2Tl(as per annexure iii RPPI-SASl ii Unit Amount in Nos. 20.07 Nos. 20.22 iv 220 kV Bus Coupler Type 2BC(as per annexure RPPI-SAS) Nos. 5.55 220 kV Bus Bar Protection Type 2BBA(as per annexure RPPI-SASl Nos. 24.5 vi 1 10 kV line panel - Type lL(as per annexure RPPI-SAS) Nos. 8.37 Nos. 4.97 v vii 1 10 kV Bus Coupler panel - Type lBC 1 10/ 1 1 kV Transformer panel - Type lTl(as per annexure viii RPPI-SASl ix 66 kV line- Type 6Lfas per annexure RPPI-SAS) Nos. 16.01 Nos. 10. 14 66 kV Bus Coupler - Type 6BC(as per annexure RPPI-SAS) Nos. 7.08 Nos. 15.80 Nos. 6.82 Nos. 77.81 M.T. 0.83 M.T. 0.68 M.T. 0.92 x 66/ 1 1 kV Transformer- Type 6Tl(as per annexure RPPISAS) 1 lkV line type- lL (as per annexure RPPI-SAS) (Provision xii for 2 feeders to be made in one panel) xi xiii Sub-station automation system Rs Lakhs TOWERS: 3 Fabrication, galvanising and supply of High tensile steel tower materials Fabrication, galvanisation and supply of mild steel tower ii materials iii Supply of e:alvanised Bolts & Nuts i Amount in Rs. ACCESSORIES: 4 Set 306 ii Number Plates/Circuit Plates No. 1 16 iii Danger Plates/Caution Plates ( 1 No. per tower) No. 129 iv Earth Bond 300 mm Long No. 277 v Earth Bond 450 mm Long No. 318 a) 9 Mtr. Long 145kgs Nos. 5941 b) 9 Mtr. Long, 150Kgs working load Nos. 72 10 i Phase Plates (Set of 6 per tower) RCC POLES: 5 RIGID BUS WITH TAPS & CLAMPS 6 A RIGID BUS: Mtrs. 1291 b) 75mm Size --- l lOkV Side Mtrs. 1291 �a cJ' � ¢1 tr t Material + Labour i) Aluminium Tube Conforming to 6340 WP of IS5082 / l 969 f BS 1600-Sch.40) of followine: sizes. a) 75mm Size --- 220kV Side �T.C}..· * �} � aooc:o·9 , .. \\u /\ SI. No. . Description of Materials Unit Amount in Rs c) 63mm Size --- 66kV Side Mtrs. 909 d) 50mm Size --- 33kV Side Mtrs. 509 e) 50mm Size connecting isolator to vertical tap --- 66kV Side Mtrs. 572 f) 38mm Size connecting isolator to vertical tap --- 33kV Side Mtrs. . 405 ii) TAPS: a) Inverted 'V' taps made of 63mm Aluminium Tube (BS1600) of 2500mm vertical height for vertical portion and cross bus on 220kV Side with rounded off end. Nos. 4547 Nos. 4158 Nos. 2424 Nos. 31 10 a) Rigid Type Nos. 1 18 1 b) Expansion Type Nos. 239 1 c) Sliding Type Nos. 1 165 a) Rigid Type Nos. 829 b) Expansion Type Nos. 2264 c) Sliding Type Nos. 868 a) Rigid Type Nos. 829 b) Expansion Type Nos. 2263 c) Sliding Type Nos. 868 b) 75mm Nos. 532 c) 63mm Nos. 310 d) 50mm Nos. 310 b) Straight taps made of 63mm Aluminium Tube (BS-1600) of 1750mm vertical height for vertical portion and cross bus on l lOkV side with rounded off end. c) Straight taps made of 50mm Aluminium Tube (BS- 1600) of 1250mm vertical height for vertical portion and cross bus on 66kV side with rounded off end. d) Straight taps made of 38mm Aluminium Tube (BS- 1600) of lOOOmm vertical height for vertical portion and cross bus on 33kV side with rounded off end. iii) CLAMPS: Post insulator Clamp suitable for 75mm Aluminium pipe A and post insulators Solid core type. Post insulator Clamp suitable for 63mm Aluminium pipe and post insulators Solid core tvpe. B c Post insulator Clamp suitable for SOmm Aluminium pipe and post insulators Solid core type. D Corona Bell Suitable for Aluminium pipe of Size �; �er.era/4i. 9' :f. � ��� � !o�.:: ) iii' .... ,, • --n .,o ·�c .,_'-L. � � ·--'":'.'":'-:-""--::...-� • .£) �'!fl�·!S'" 000010 '. ' '· ' . I ' . ;_t 'r SI. No. Description of Materials Unit Amount in Rs Lakhs CONDUCTORS: 7 a) Coyote ACSR KM b) Lynx ACSR KM KM d) Moose ACSR KM 3.71 f) AAAC - Moose KM 3.9 1 f) 7 /3. 15 mm G.I. Wire for ground conductor KM 0.46 g) 7 /3.65 mm G.I. Wire for ground conductor KM 0.62 a) Solid Core Insulators 220 kV No. 21053 b) Solid Core Insulators 1 10 kV No. 8254 c) Solid Core Insulators 66kV No. 4139 d) Solid Core Insulators 33kV No. 2529 e) Disc Insulator 70 KN No. 402 f) Disc Insulator 90 KN No. 415 No. 534 h) Disc Insulator 160 KN No. 801 i) 33 kV Pin Insulator Shell with pin No. 388 j Pins for above No. 155 k) Solid core long rod insulators 90KN No. 42 14 1) Solid core long rod insulators 120KN No. 17899 m) Solid core long rod insulators 160KN No. 18492 n) 220kV Polymer disc insulator Set 8010 o) l lOkV Polymer disc insulator Set 33 18 p) 66kV Polymer disc insulator Set 2074 Amount in Rs. Lakhs TELECOMMUNICATION EQUIPMENTS A Wave Trap: b) 0.5 mH 800A ( Suspension tvue ) c) 1.0 mH 2000A B c 2.94 Amount in Rs. - g) Disc Insulator 120 KN 9 1.45 " c) Drake ACSR INSULATORS: 8 0.95 Set 1.5 1 Set 4.78 Set 1.95 Set 5.83 Couplini:t Capacitors: l)Coupling Capacitors 8800 pf/4400 pf with clamps PLCC Terminals {Carrier cabinets): a) Twin Channel 000011 Sl. N o. Description of Materials b) Single Channel Amount in Rs Unit Lakhs Set 4.85 a) Coupling Ph/Ph Set 1.22 b) Coupling Ph/Gnd Set 0.77 Kms 1.22 Trunk/E&M/Line 8/8/16 No 3.98 Trunk/E&M/Line 8/8/8 No 3.07 4 commands No 2.14 2 commands No 1.36 No 0.01 D Coupling Device with protective device: E HF Co-axial Cable 75 ohms F EPAX for PLCC: G Protection couplers: H Telephone 2 wires: I J Amount in Rs. Over Head Cables (Unshielded) a) 20 Pair PVC/OH telephone Cable 0.5 1mm dia conductor Mtr. 36 b) 5 Pair PVC/OH telephone Cable 0.5 1 mm dia conductor Mtr. 21 5 Pair PVC telephone Cable 0.5 1mm dia conductor with shield Mtr. 31 Mtr. 7 a)Push button telephone Per Unit 357 b)Plan 103 P.B. telephone ( 1 Main & 1 Extn) Per Set 2265 c)Panasonic Plan 103( 1 Main & 1 Extension) Per Set 8352 a) lOpair No. 175 b)20pair No. 206 c)50pair No. 360 d) lOOpair No. 515 Nos. 139 Nos. 283 K 0.9 1mm Copper drop wire L Telephone Instruments: M KRONE BOX: N a) Krone modules for 1 0 pairs isolation type b) Krone modules for 100 pairs( lONos each row) 000012 SI. No. p Description of Materials Unit 1) 20 pair Mtrs. 100 Per kit 764 No 1053000 1) Portable(mobile) Oil Pump ( 1/2 HP Air Pump 500 to 1000 l!allons) No 10305 2) Telescopic Ladder aluminium 6 Mtr. Height No 22328 3) Ring spanners-12Nos per set Set 791 4) Tube Spanners- 12Nos per set Set 396 5) Pipe wrench 24 inches size No 791 6) Pipe wrench 18 inches size No 459 7) Double end spanner- 12Nos per set Set 422 8) Hack saw frames +B l85 Nos. 185 9) Hydraulic crimping tool upto lOOOSq.mm Nos. 35495 10) Rubber hand gloves 15kV tested Pair 149 1 1 ) Hand Torch 5 celled No 447 12) Hand Torch 3 celled No 378 13) Insulated cutting pliers 12 inches size No 200 No 142 15) Line live tester No 158 16) Screw driver 18 inches size No 148 17) Screw driver 12 inches size No 95 18) Hammer 8 Lbs. No 253 19) Hammer 2 Lbs. No 127 20) Chain pulley block 5Ton Capacity No 246 18 21) Hydraulic Jack 5Ton Capacity No 3587 22) Pipe derrick No 14243 23) Allen keys Set 243 24) Box spanners- 12Nos per set Set 3640 25) Transil oil Dielectric Breakdown testkit No 74425 26) Insulation Tester (Megger) 2.5kV-5kV No 38930 Rs Straight through joint kit for J.F.U.G.Cable of 0.63mm dia Conductor, TSF (Thermo Shrink Filled Closure type) 1) 20 pair TSF- 1 Q Remote terminal unit 10 Amount in TOOLS AND PLANT: 14) Insulated cutting pliers 8 in size , 000013 ,, - I� SI. Description of Materials No. Unit Amount in 27) Insulation Tester (Megger) 500V rating No 10878 28) SF6 gas leak detector No 33205 29) Multimeter electromechanical type No 2290 30) Multimeter electronic type No 4981 31) Hydrometer No 458 32) D.C.Volt meter range-3V to +5V No 1374 33) Hydrometer syringe suitable for vent holes No 458 34) Specific gravity correction chart No 458 35) Wall mounting type holder for Hydro·meter No 1374 36) Earth resistance tester No 143 13 37) Arc welding machine ( 10 kVA) No 2 1 183 38) Thermometer with wall mounting holder No 1374 39) Rubber appron No 973 40) Pippette No 401 41) Protective Goggle No 458 42) Acid Resisting jars (4 print capacity) No 458 Pair 1088 44) Glass Funnel No 344 45) Hickery rods No 2748 46) Grounding sticks No 332 1 47) Manilla rope '1" Mts. ( 100) 1 1 107 48) Manilla rope '3/ 4" Mts. ( 100) 1 1 107 49) Files of sizes No 4408 50) Portable drilling M/C with stand (heavy duty) No 2 1755 51) Hand drilling M/C No 10878 52) Safety belts 53) Safety helmets No No 618 229 54) Steel Measuring tape 30 Mtrs. No 630 55) Steel Measuring tape 15 Mtrs. 56)Man:ual crimping tool upto 400sqmm No No 452 2279 No Pair 1660 1592 No 372 13 43) Rubber shoes knee height 57)Rain coat with dick back 58)Gum Boots 59)Bolt cutter-hydraulic �eral Mq/J. . Ql 0'll ���� Q. IJ.) Cl \• 0•11') Cl> g. �1-; �;q.l.>f:�� - Rs 000014 Amount in Rs. Sl No. Description of Materials Unit Drake ACSR Lynx ACSR 11 Coyote ACSR Rabbit ACSR Ground Conductor 628 A HARDWARE 1 Single Tension Clamps with arcing horns Nos. 1913 835 764 600 2 Double Tension Clamps with arcing horns Nos. 3407 2377 2208 1965 3 Single Suspension Clamps with arcing horns Nos. 1 195 1014 938 625 4 Double Suspension Clamps with arcing horns Nos. 2268 1935 1 9 13 1716 5 P.G. Clamps Nos. 658 395 274 96 205 6 M.S,.C. Joints Nos. 585 340 316 210 233 7 Pre-formed Armour Rods Nos. 1702 643 55 1 445 8 Repair Sleeves Nos. 450 301 153 1 12 9 Vibration Damper Nos. 785 5 16 434 466 Nos. 4028 3870 3870 3870 Nos. 572 568 5 10 411 10 Automatic Come - along Clamp 1 1 Pad Clamps �e•,,'IJ.\ IVl8/]�� (!) � � I !=;� �* \t 0 � o""·'� "?.g. �! '"o/,1 1.,;_ • .Lo ' 662 157 2121 000015 ' " lb I SI. Description of Materials No Qty Amount in Rs. Hardware Clamps for Station materials Bolted Type tension Clamp B c 1) Twin Falcon ACSR Conductor 120KN 20mm Nos. 2593 2) Twin Drake ACSR Conductor 120KN 20mm Nos. 2231 3) Twin Moose ACSR Conductor 120KN 20mm Nos. 2323 4) Twin Falcon ACSR Conductor 90KN 16mm Nos. 2102 5) Single Falcon ACSR Conductor 120KN 20mm Nos. 1366 6) Twin Drake ACSR Conductor 90KN 16mm Nos. 2027 7) Single Falcon ACSR Conductor 90KN 16mm Nos. 1324 8) SingleDrake ACSR Conductor 120KN 20mm Nos. 1280 9) SingleDrake ACSR Conductor 70/90KN 16mm Nos. 1235 lO)Single LYNX ACSR Conductor 70/90KN 16mm Nos. 719 l l)Single Coyote ACSR Conductor 70/90KN 16mm Nos. 675 12) Single Rabbit ACSR Conductor 70/90KN 16mm Nos. 508 Nos. 1944 1) Twin Falcon ACSR Conductor 90KN 16mm Nos. 2395 2) Twin Moose ACSR Conductor 90KN 16mm Nos. 2215 3) Twin Drake ACSR Conductor 90KN 16mm Nos. 2092 4) Single Falcon ACSR Conductor 90KN 16mm Nos. 978 5) SingleDrake ACSR Conductor 70/90KN 16mm Nos. 857 6) Single LYNX ACSR Conductor 70/90KN 16mm Nos. 642 Wedged clamps 1) Single Tension Clamp Compression type Drake ACSR D Bolted Type Suspension Clamp fll"-a\Man� lb� � I !j� � � � o\• o* .o+•''). "" � �g. ii! ��·* -'tP.r.C I 000016 SI. No E Qty 7) Single Coyote ACSR Conductor 70/90KN 16mm Nos. 582 8) Single Rabbit ACSR Conductor 70/90KN 16mm Nos. 466 Nos. 658 1) Twin Falcon ACSR Conductor 127mm 220KV Nos. 972 2) Twin Moose ACSR Conductor 127mm 220KV Nos. 831 Nos. 779 Nos. 561 Nos. 514 Nos. 480 Nos. 444 Nos. 407 1) Twin Falcon 220KV Nos. 359 2) Twin Moose 220KV Nos. 338 3) Twin Drake 220/110/66KV Nos. 322 1) Twin Falcon to Single Drake Nos. 1037 2) Twin Moose to Single Drake Nos. 781 3) TWin Drake to Single Drake Nos. 669 4) Single Falcon to Single Drake Nos. 421 5) Single Drake to Single Drake Nos. 370 6) Single Drake to Single Lynx Nos. 346 Post insulator Clamps 3) Twin Drake ACSR Conductor 127 mm 220/110/66KV 4) Single Falcon ACSR Conductor 220/110/66KV 5) Single Drake ACSR Conductor 127/76mm, 220/110/66/33KV 6) Single Lynx ACSR Conductor 127/76mm, 110/66/33KV 7) Single Coyote ACSR Conductor 127/76mm, 66/33KV 8) Single Rabbit ACSR Conductor 76mm, 33KV G H Rs. Hardware Clamps for Station Materials 1) Ground Wire Clamp 7 /3.15mm 2 bolt F Amount in Description of Materials Spacer Clamp for ACSR Conductors Requirement of Power Connectors 'T' Clamps for ACSR Conductors. 000017 SI. No I J K Amount in Description of Materials Qty 7)Single Drake to Single Coyote Nos. 325 8) Single Lynx to Single Lynx Nos. 273 9)Single Coyote to Single Drake Nos. 325 10) Single Lynx to Single Drake Nos. 346 11) Single Coyote to Single Coyote Nos. 259 1) Twin Drake Nos. 940 2) Single Drake Nos. 567 3) Single Lynx Nos. 437 4) Single Coyote Nos. 376 1) 63mm nominal diameter x 73.03mm Nos. 1009 2) 50mm nominal diameter x 60.03mm Nos. 860 1) Rabbit to Coyote ACSR Conductor Nos. 704 2) Rabbit to Lynx ACSR Conductor Nos. 1147 3) Rabbit to Drake ACSR Conductor Nos. 1970 4) Coyote to Coyote ACSR Conductor Nos. 1032 5) Coyote to Lynx ACSR Conductor Nos. 1261 6) Coyote to Drake ACSR Conductor Nos. 1444 7) Lynx to Lynx ACSR Conductor Nos. 1277 8) Lynx to Drake ACSR Conductor Nos. 1512 9) Drake to Drake ACSR Conductor Nos. 1939 Nos. 1199 11) Rabbit to 2 hole paddle ACSR conductor-895A Nos. 1303 12) Coyote 2 hole paddle ACSR Conductor-6 lOA Nos. 1459 Rs. Power Connectors. Terminal connector clamps for ACSR Conductor Power connectors. Expansion type terminal connectors suitable for Aluminium pipes C type Wedge Connectors 10) Rabbit to 2 hole paddle ACSR Conductor o\r � P. o ::;, �I -· �'·!.'!?� T.C�· ,$ ..., ......,,,.•,<... *,_. .._...... - 6 lOA 000018 SI. No Amount in Description of Materials Qty 13) Coyote 2 hole paddle ACSR Conductor-895A Nos. 1668 14) Coyote 2 hole paddle ACSR Conductor- 1400A Nos. 3815 15) Coyote 4 hie Paddle ACSR Conductor-610A Nos. 1616 16) Coyote 4 hole paddle ACSR Conductor-895A Nos. 1731 17) Coyote 4 hole paddle ACSR Conductor-1400A Nos. 3701 18) Lynx 2 hole paddle ACSR Condcutor-610A Nos. 2064 19) Lynx 2 hole paddle ACSR Conductor-895A Nos. 2064 20) Lynx 2 hole paddle ACSR Conductor-1400A Nos. 3909 21) Lynx 4 hole paddle ACSR Conductor-610A Nos. 2346 22) Lynx 4 hole paddle ACSR Conductor-895A Nos. 2450 23) Lynx 4 hole paddle ACSR Conductor-1400A Nos. 3909 24) Drake 2 hole paddle ACSR Conductor-6 lOA Nos. 3753 25) Drake 2 hole paddle ACSR Conductor-895A Nos. 3753 26) Drake 2 hole paddle ACSR Conductor-1400A Nos. 4159 27) Drake 4 hole paddle ACSR Conductor-610A Nos. - 2606 28) Drake 4 hole paddle ACSR Conductor-895A Nos. 3075 29) Drake 4 hole paddle ACSR Conductor-1400A Nos. 4159 30) Rabbit to Rabbit ACSR Conductor Nos. 417 31) Drake to Moose ACSR Conductor Nos. 2971 Rs. 000017 SI. No Qty 32) Drake to Falcon ACSR Conductor Nos. 8861 33) Moose to Moose ACSR Conductor Nos. 3075 34) Moose to Falcon ACSR Conductor Nos. 9069 35) Falcon to Falcon ACSR Conductor Nos. 9174 Nos. 5473 Nos. 5473 Nos. 5473 Nos. 5473 Nos. 14178 Nos� 14178 1) Numerical distance relay for 220 kV system Nos. 211021 2) Numerical distance relay for 66 kV system Nos. 309686 Nos. 351000 Nos. 19481 5) Restricted Earth fault relay Nos. 11700 6) Single pole over current/ Earth fault relay Nos. 7125 7) Trip circuit Supervision relay Nos. 7184 8) Auxiliary relay -2 element Nos. 5792 9) Master trip relay Nos. 9828 36) Moose 2 hole paddle ACSR Conductor & 2 hole paddle-895A 37) Moose 2 hole paddle ACSR Condcutor & 2 hole paddle-1400A 38) Moose 4 hole paddle ACSR Conductor & 4 hole paddle-895A 39) Moose 4 hole paddle ACSR Conductor & 4 hole paddle-1400A 40) Falcon 2 hole paddle ACSR Conductor & 2 hole paddle-1400A 41) Falcon 4 hole paddle ACSR Conducotr & 4 hole paddle-1400A 12 Amount in Description of Materials Rs. Relays: 3) Static/Digital/Numerical Differential relay for Transformer protection for SAS station 4) Single pole Directional over current/ Earthfault relay 00002'.J 2/ SI. No Description of Materials 10) Single pole Non-directional over current/ Qty Amount in Rs. Nos. 8681 11) Auxiliary relay -3 element Nos. 4753 12)Under frequency relay Nos. 70200 13) Line Differential relay Nos. 351000 Earthfault relay with HS 000021 SI. Material No 13 Unit Amount in Rs. A MISCELLENEOUS ITEMS a) l lkV GOS D/B 1200A Set 34340 b) l lkV GOS D/B 800A Set 31089 c) l lkV GOS D/B 400A Set 24358 d) 1 lkV GOS S/B 400A Set 18855 e) l lkV GOS S/B 200A Set 12355 f) 1 lkV 400A, Special roster GOS Set 15444 g) 1 lkV HG Fuse unit Nos. 6 13 h) 9kV, 5kVA lightning Arrestor (Metal oxide type) Nos. 636 i) 1 1 kV UG Cable 1 Core 1000 sq.mm Km 980000 ii) 1 1 kV UG Cable 3 Core 400 sq.mm Km 1675000 iii) 1 1 .kV UG Cable 3 Core 240 sq.mm Km 1209000 iv) 1 1 kV UG Cable 3 Core 95 sq.mm Km 646580 i) 3 x 95 Sq.mm Nos. 7187 ii) 3 x 240 Sq.mm Nos. 888 1 iii) 3 x 400 Sq.mm Nos. 9045 iv) lx 1000 Sq.mm Nos. 7576 i) 3 x 95 Sq.mm Nos. 3477 ii) 3 x 240 Sq.mm Nos. 4268 iii) 3 x 400 Sq.mm Nos. 4905 iv) lx 1000 Sq.mm Nos. 3835 i) 3 x 95 Sq.mm Nos. 4253 ii) 3 x 240 Sq.mm Nos. 4268 iii) 3 x 400 Sq.mm Nos. 5036 iv) lx 1000 Sq.mm Nos. 4330 B HV CABLES 1 lkV JOINTS AND POT HEADS 14 A Heat Shrinkable type transition jointing kit for XLPE Cable B Cold Shrinkable type termination kit for XLPE Cable a) Indoor b) Outdoor 000022 SI. Material No 13 Unit Amount in Rs. A MISCELLENEOUS ITEMS c D Cold Shrinkable type transition jointing kit for XLPE Cable i) 3 x 95 Sq.mm Nos. 17996 ii) 3 x 240 Sq.mm Nos. 16724 iii) 3 x 400 Sq.mm Nos. 17369 iv) lx 1000 Sq.mm Nos. 7744 i) 3 x 95 Sq.mm Nos. 22 19 ii) 3 x 240 Sq.mm Nos. 2736 iii) 3 x 400 Sq.mm Nos. 6231 iv) lx 1000 Sq.mm Nos. 1892 i) 3 x 95 Sq.mm Nos. 1987 ii) 3 x 240 Sq.mm Nos. 2736 iii) 3 x 400 Sq.mm Nos. 945 1 iv) lx 1000 Sq.mm Nos. 2 129 i) 3 x 95 Sq.mm Nos. 4674 ii) 3 x 240 Sq.mm Nos. 5283 iii) 3 x 400 Sq.mm Nos. 638 1 iv) lx 1000 Sq.mm Nos. 5539 i) 45 liters capacity Nos. 1 1224 ii) 9 liters capacity Nos. 2 157 b)Water type (Gas pressure type) 9 liters capacity Nos. 1849 c) Carbondioxide type 6 liters capacity Nos. 6 106 1 lkV Heat Shrinkable Cable termination kit for XLPE Cable a) Indoor b) Out door E 15 1 lkV Heat Shrinkable Straight through jointing kit for XLPE Cable with Copper Lugs & Aluminium Ferrules Fire Fightning equipments with necessary mounting stands a) Foam extinguishing type d) Stand type 000023 SI. Material No 13 Unit Amount in Rs. A MISCELLENEOUS ITEMS i) G.I.Buckets 9 Liters capacity Nos. 252 ii) Steel stands Nos. 938 e) Nitrogen Injection fire extinguishing system for lOOMVA and above Power Transformers Set 859163 f) Nitrogen Injection fire extinguishing system for Power Transformers below lOOMVA Set 675036 16 ELECTRIC GENERATING SET COMPRISING OF; 50KW/62.5kVA Diesel Generating Set rated at 50KW/62.5kVA 4 1 5V, 0.8PF, Mounted on a Base Frame, Complete with Inbuilt Fuel Tank and battery 1 No. 12V & Inbuilt Standard Manual Control Panel with Acoustic Enclosure - NAL Approved.D.G. Set 63kVA Capacity with AMF panel Nos. 576000 17 Station Auxiliary Transformer with oil, cable termination type on both HT & LT outdoor type 100 kVA, l lkV/433 V, 3 phase Dyl l Nos. 195574 a) 250kVA Nos. 288800 b) 100 kVA Nos. 195574 a) 250kVA Nos. 182 19+702 b) lOOkVA Nos. 10400+28 1 a) 25mm width Mtrs 383 b) 50mm width Mtrs 766 c) 75mm width Mtrs 1 148 d) lOOmm width Mtrs 153 1 B) Epoxy shroubs suitable for 1 lkV outdoor bus Mtrs 2024 A Supply and errection of 3 Ph 1 lkV/433 V distribution Transformer with copper windings B Supply & Fixing LT distribution box 18 A 1 lkV Insulation Tapes (HV BT Tapes) 000024 Sl. No Material Unit Supply rates in Rs. Lakhs Labour rates in Rs. 19 400kV SUB-STATION MAIN EQUIPMENTS As per the weight or the transformer As per the weight or the reactor 1 167 MVA, 400/220/33 kV single phase Inter-connecting transformer(ICT) Set 5 17.24 2 420 kV Class, 63MVAR Bus Reactor as per bid specification along with Neutral ground Transformer Nos 344.48 Set 32.8 50588 i) 3-Pole with single earth switch. Set 8.62 16864.38 ii) 3-Pole without earth switch. Set 7.07 16188. 12 Set 7.03 17537. 13 Nos 7.27 9227.79 i) 390kV Class Nos 1.08 9227.79 ii) 120 kV Class(For NGT) No. Circuit breaker SF6 type, with operating mechanism and marshalling box along with associated support structure and terminal connector etc.. as oer bid soecifiaction. Al 420 kV Class 40 kA, 2000A !without closin� resistors) Isolators with operating mechanism and marshalling boxes, 4 terminal connectors etc as oer bid soecifications. 3 A) 420kV, 40kA 3 150A pantograph type B) 420kV, 40kA 3 150A Centre break type i) 3-Pole with double earth switch. 5 Current transformers having 5 Cores, with marshalling boxes, teminal connectors etc., as per bid specification. A) 420kV Class, 40kA CT with ratio 3000-2000/ 1-1 & 500200/ 1 - 1 - 1 6 Surge Arresters with insulating base, surge monitor, terminal connectors etc as per bid specifications. Capacitor Voltage transformers having 5 Cores, with 7 marshalling boxes, teminal connectors etc., as per bid soecification. Nos 3.99 a) Back-up control panel for 400 kV reactor Set 3.34 10792.08 b) Relay panels for 400 kV Reactor Set 14.0 1 10792.08 c)400kV Line - type 4L (As per ANNEXURE Feeder Panel SAS) Nos 22.05 10792.08 d)400/220/33kV Trasformer - Type 4T (As per ANNEXURE Transformer Panel - SAS) Nos 27.09 10792.08 i) For 400 kV Panels Nos. 2.02 ii) For 220 kV Panels Nos. 1 .77 A) 420kV Class, 8800PF 8 Control & Relay equipment complete as per bid specification e)Marshalling bay kiosks.(as per technical specifications, along with Air conditioning system). 9 BUS AND HARDWARE FITTINGS:A Aluminum tube, confirming to 6340WP of IS 5082, 1969, BS 1600Sch 40 of size lOOmm (4") Size �lJ\anaUe�- Mtres Amount in Rs. 2282 - � �::::: ' I ]!-� Q4Y\� ff) J (!j t\, . o\� o* tu ,frs:r.c:'J>::j'Jl ..-.._�,,# 000025 Unit Supply rates in Rs. Hardware set for 400kV Double Tension string assembly with double anchoring points including turn buckle, corona ring B and tension clamp and complete set suitable for Twin moose ACSR bundle with 450mm sub conductor spacing. Set 18559 Hardware set for 400kV Single suspension string insulators assembly including corona ring, suspension clamp and c complete set etc., suitable for Twin moose ACSR bundle with 450mm sub conductor snacine-. Set 9593 Set 16484 Set 7228 Set 82 13 Set 3684 Nos 35900 Nos 32 14 Nos 3318 Sl. No Material Labour rates in Rs. Hardware set for 220kV Double tension string assembly with D double anchoring points including turn buckle arcing horn, tension clamps and complete set etc suitable for a.Quadruple moose ACSR bundle with 250mm sub-conductor spacinf!'. b.Twin moose ACSR bundle with 250mm sub-conductor spacinf!'. Hardware set for· 220kV single suspension string insulator E ·assembly including arcing horn, suspension clamp and complete set etc., suitable for a.Quadruple moose ACSR bundle with 250mm sub-conductor spacing. b.Twin moose ACSR bundle with 250mm sub-conductor spacing. F 400kV Class Bus Post Insulators G 400kV clamns and connectors Terminal connector for CB to receive 4" IPS Al. tube flexible i tvpe Terminal connector for CT to receive 4" IPS Al. tube flexible ii tvpe iii Terminal connector for Centre Break Isolator to receive Nos a) 4" IPS Al. tube flexible type Nos 32 14 b) Twin Moose ACSR conductor suitable for vertical take off 450 mm spacing Nos 1995 a) 4" IPS Al. tube Expansion type Nos 3 1 67 b) 4" IPS Al. tube Rigid type Nos 2885 c) 4" IPS Al. tube Sliding type Nos 1709 C' type wedge connector suitable for Moose ACSR to Moose ACSR Nos 4133 a)T' Clamp suitable for 4" IPS Al. tube to twin moose ACSR conductor Nos 23 1 1 b)T clamp sutable for 4"Al.tube to 4" Al.tube. Nos 2269 a)Flexible Nos 2354 b)Rigid Nos 1278 Nos 1884 Nos 16 1 1 iv Terminal Connector for BPI to receive v vi T' clamps vii Spacers for Quadruple Twin moose ACSR conductor with 450mm spacing Terminal connector for LA to receive ACSR twin moose viii conductor suitable for horizontal/vertical take off with 450mm snacine- ix Welding sleeve suitable for 4 inch IPS Al. tube ��"11an'We �e; ;.";:; ��� Ib � -�� � '·/, 01t oA••> � * kPTCl-·"'15- ·� _? ·- 0· 000020 Unit Supply rates in Rs. Nos 30 12 a} Twin Moose ACSR conductor Nos 1961 b} 4" IPS Al. tube flexible type Nos 3 132 a} 4" IPS Al. tube flexible type Nos 30 12 b} 4" IPS Al. tube Rigid through type Nos 1526 c} Twin moose ACSR conductor suitable for Vertical take off 250mm spacing Nos 1373 d} Twin moose ACSR conductor suitable for horizontal take off 250mm spacing Nos 1373 Terminal Connector for CVT to receive 4" IPS Al. tube Rigid type Nos 1584 Nos 1590 a}4" IPS Al. tube (od: 1 14.3mm, ID:97. 18mm} Expansion type Nos 4004 b} 4" IPS Al. tube Rigid type Nos 1558 c} 4" IPS Al. tube Sliding type Nos 1679 T' clamp suitable for 4" IPS Aluminium tube to twin moose conductor Nos 1744 SI. No Material Labour rates in Rs. H 220kV Clamps and Connectors i Terminal connector for CB to receive 4" IPS Al. tube flexible type ii Terminal connector for CT to receive iii Terminal Connector for isolator to receive iv v Terminal Connector for CVT to receive Twin Moose ACSR vi vii Clamps for Aluminium tube suitable for BPI for both main bus & interconnecting bus viii T clamp suitable for Quadruple Moose ACSR to 4" IPS Al. tube 2573 ix C' type wedge connector suitable for Quad Moose ACSR to Quad Moose ACSR 4058 x C' type wedge connector suitable for Quad Moose ACSR to Twin Moose ACSR 4058 xi Spacers for twin ACSR Moose Conductor with 250mm spacing a} Flexible 1092 b} Rigid 435 Terminal connector for LA to receive ACSR twin Moose xii conductor suitable for horizontal take off with 250mm sJ>acin2 1373 xiii Welding sleeve suitable for 4 inch IPS Al. tube 1611 xiv Corona Bell suitable for 4 inch IPS Al. Tube 532 I 72 kV clamps and connectors i Terminal connector for PT to receive 2.5 IPS Al. Tube rigid type Nos. 1093 ii Terminal connector for isolator to receive 2.5 IPS Al. Tube flexible type Nos. 23 1 1 iii Clamps for Aluminium tube suitable for BPI for both main bus & interconnecting bus 00002T Sl. No Unit Supply rates in Rs. a)2.5 IPS Al.Tube(od: 1 14.3mm, ID: 97. 18 mm) Expansion type Nos. 3279 b) 2.5 IPS Al. Tube Rigid type Nos. 1009 c) 2.5 IPS Al. Tube Sliding type Nos. 1 12 1 iv Welding sleeve suitable for 2.5 inch IPS Al. tube Nos. 51 1 v Corona Bell suitable for 2.5 inch IPS Al. Tube Nos. 250 Material vi Straight tap suitable for connecting 2.5 inch IPS Al. tube to connect 33kV Main bus to 33kV equipment bus Nos. 1247 vii T·Clamp suitable for connecting 2:5 IPS Al. tube of 2.5" IPS Al. tube Nos. 2353 Labour rates in Rs. Amount in Rs.Lakhs 10 Insulator with hardware for Twin Moose ACSR conductor a) Single suspension fittings with 23 Nos. of 120KN insulators and hardware set Set 0.26 b) Double suspension fittings with 2x23 Nos. of 120KN insulators and hardware set Set 0.47 c) Single Tension fittings with 24 Nos. of 160KN insulators and hardware set Set 0.3 12 d) Double Tension fittings with 2x24 Nos. of 160KN insulators and hardware set Set 0.579 e) Pilot insulators fittings with 23 Nos. of 120KN Disc insulators and hardware set Set 0.225 a) Mid span compression joint No 0.00933 b) Repair sleeves No 0.00398 c) Vibration dampers No 0.00898 d) Bundle Spacers for Line No 0.00902 e) Rigid Spacers for Jumpers No 0.0048 1 f) Balancing weights No 0.26415 g) T-Connectors No 0.0 1355 a) Mid span compression joint No 0.00292 b) Compression type tension clamp No 0.0057 c) Suspension clamps No 0.00599 d) Repair sleeves No 0.00292 e) Vibration dampers No 0.00396 1 1 Accessories for Conductors 12 Hardware and Accessories for Ground Wire of size 7 / 3.66mm 13 Check survey & tower spotting km a) Hilly terrain Per Km 3202 b) Plain Terrain Per Km 2137 km 3579 1 14 Stringing of conductor & ground wire a) Stringing of ACSR MOOSE conductor including Installing insulator strings complete with necessary hardwares , and fixing of conductor accessories,tower accessoreis etc. a � '2i �c;;- � � I� �- I �'y·"*'� � * k. P.i 000 02'3 Unit Amount in Rs Lakhs 1 127/220KV Single core 1000 Sq.mm., XLPE insulated, Lead Sheathed overall PE Sheathed UG cable (E) grade,lcore, circular, stranded, playing annealed compacted copper conductor, screen on extruded semi conducting compound, XLPE insulation; inulation screen of semiconducting compound, non-woven water swellable semi conducting tape extruded lead alloy (E) sheath, semi conducting bedding tupe (s) helically applied copper wires open helix copper tape, nonwoven swellable tape, extruded PVC ST2 sheath conducive coating & antitermite treated.high density poly-ethylene outer sheathed copper cable as per Technical specifications. Kms. 193.62 2 UOKV, 630Sq mm XLPE UG Cable UOKV (E) grade, 1 core, Circular, stranded, plain annealed copper condutor, conductor screen on extruded semi conducting compound, cross linked polyethylene (XLPE) insulation, core screen, semi-conducting water swellable layer, extruded lead alloy (E) sheath, semi conducting bedding tapes, helically applied plain round copper wire screen, plain copper tape in open helix, water swellable tape with overall extruded high density polyethylene sheath, coated with graphite etc., as per technical specification. Kms. 78.80 3 UOKV, 400Sq mm XLPE UG Cable UOKV (E) grade, 1 core, Circular, stranded, plain annealed copper condutor, conductor screen on extruded semi conducting compound, cross linked polyethylene (XLPE) insulation, core screen, semi-conducting water swellable layer, extruded lead alloy (E) sheath, semi conducting bedding tapes, helically applied plain round copper wire screen, plain copper tape in open helix, water swellable tape with overall extruded high density polyethylene sheath, coated with graphite etc., as per technical specification. Kms. 66.00 4 UOKV, 240Sq mm XLPE UG Cable UOKV (E) grade, 1 core, Circular, stranded, plain annealed copper condutor, conductor screen on extruded semi conducting compound, cross linked polyethylene (XLPE) insulation, core screen, semi-conducting water swellable layer, extruded lead alloy (E) sheath, semi conducting bedding tapes, helically applied plain round copper wire screen, plain copper tape in open helix, water swellable tape with overall extruded high density polyethylene sheath, coated with graphite etc., as per technical specification. Kms. 56.00 ·SI.No 20 I Name of the equipment EHV UG CABLES EHV UG cables 0 0 0029 3o Unit Amount in Rs Lakhs 5 66KV, lOOOsqmm XLPE UG Cable 66KV (E) grade, 1 core, Circular, stranded, plain annealed Segmental compact type miliken copper condutor, conductor screen on extruded semi conducting compound, cross linked polyethylene (XLPE) insulation, core screen, semi-conducting water swellable layer, extruded lead alloy (E) sheath, semi conducting bedding tapes, helically applied plain round copper wire screen, plain copper tape in open helix, water swellable tape with overall extruded high density polyethylene sheath, coated with graphite etc., as per technical specification. Kms. 106.00 6 66KV, 630sqmm XLPE UG Cable 66KV (E) grade, 1 core, Circular, stranded, plain annealed Segmental compact type miliken copper condutor, conductor screen on extruded semi conducting compound, cross linked polyethylene (XLPE) insulation, core screen, semi-conducting water swellable layer, extruded lead alloy (E) sheath, semi conducting bedding tapes, helically applied plain round copper wire screen, plain copper tape in open helix, water swellable tape with overall extruded high density polyethylene sheath, coated with graphite etc., as per technical specification. Kms. 68.16 7 66KV, 240sqmm XLPE UG Cable 66KV (E) grade, 1 core, Circular, stranded, plain annealed Segmental compact type miliken copper condutor, conductor screen on extruded semi conducting compound, cross linked polyethylene (XLPE) insulation, core screen, semi-conducting water swellable layer, extruded lead alloy (E) sheath, semi conducting bedding tapes, helically applied plain round copper wire screen, plain copper tape in open helix, water swellable tape with overall extruded high density polyethylene sheath, coated with graphite etc., as per technical specification. Kms. 45.44 II EHV UG CABLES ACCESSORIES: 1 Out door type Cable end termination Procelain Design type suitable for the above 127 /220KV (E) class single 1 core 1000 sq.mm lead sheathed cable including PVC Earthing cable. Nos. 6.87 Nos. 2.96 Nos. 2.22 Nos. 1.71 SI.No 2 3 4 Name of the equipment Outdoor type cable end termination suitable for 1 lOKV (E) 1 core, 630sqmm lead sheathed cable including PVC earthing cable. Outdoor type cable end termination suitable for l lOKV (E) 1 core, 400sqmm/240sqmm lead sheathed cable including PVC earthine: cable. Outdoor type cable end termination suitable for 66KV (E) 1 core, lOOOsqmm, Segmental compact type miliken copper conductor, XLPE, lead sheathed cable including PVC earthing cable. 00003] Unit Amount in Rs Lakhs Nos. 0.85 Nos. 5.62 7 Normal Straight Joints suitable for 1 lOKV(E) 1 -core 630 sqmm copper conductor XLPE, Lead sheathed cable, Complete with all accessories as per technical specifications Nos. 1.78 8 Normal Straight Joints suitable for l lOKV(E) 1 -core 400 sqmm/240sqmm copper conductor XLPE, Lead sheathed cable, Complete with all accessories as per technical specifications Nos. 1.46 Nos. 1.004 Nos. 0.85 Nos. 4.77 Nos. 0.47 Nos. 0.35 Kms. 1 .02 Kms. 0.61 SI.No 5 6 9 10 11 12 13 III Name of the equipment Outdoor type cable end termination suitable for 66KV (E) 1 core, 630/240sqmm, Segmental compact type miliken copper conductor, XLPE, lead sheathed cable including PVC earthing cable. Normal Straight through joints suitable for 200KV 1 core pre mounted desing lOOOsq.mm copper conductor, XLPE lead sheathed cable. 127/220KV class single core 1000 sq.mm cable as at SI. No. 1 . Normal Straight Joints suitable for 66KV(E) 1 -core 1000 sqmm, Segmental compact type miliken copper conductor, XLPE, Lead sheathed cable Normal Straight Joints suitable for 66KV(E) 1 -core 630/240 sqmm, Segmental compact type miliken copper conductor, XLPE, Lead sheathed cable 220kV :- Cross Bonding ,Link Boxes, Single phase out door structure mounting type, with Temperature Transducers,Thermocouplers, SVL/CCPU and PVC earthing cable including lC lOOOSq mm cable as per the Technical Snecifictions Clause 7.04.00 and its Sub-Clauses. 1 lOkV:-Link boxes, single phase outdoor structure mounting type with SVL/CCPU and PVC earthing cable including the cost of lC x 400 Sq mm/240sqmm copper cable 66kV:- .Link boxes, single phase outdoor structure mounting type with SVL/CCPU and PVC earthing cable including the cost of lxlOOO Sq.mm copper cable OPTICAL FIBRES AND ACCESSORIES 2 12 Fibre Dual Window Mono Mode (DWMM) Optical Fibre Cable as per Technical Sp ecifications. Polyvinyl Lubricated Bond (PLB) pipe. 3 Straight Joint Kit for optical fibre cable. Kit. 0. 1 4 Line Interface Unit for optical fiber cable. Unit 0. 1 5 Collars for PLB pipe. No. 0.001 1 0 0 003 1 Sl. Name of the equipment No Unit Supply Rates in Rs Lakhs 2 1 Major works equipments for supply of GIS Modules Metal encapsulated SF6 gas insulated Switchgear 40KA rating suitable for indoor installation or modular desie:n 1 220kV Line (U.G. Cable) Module: No 202 . 1 9 Erection rates in Rs Lakhs 1 . 13 Each Module comprising of the following: SF6 circuit breaker Complete with operating Mechanism, 2000A, 1 Phase/3uhase -lNo Disconnector: i) 3 Phase, Single Pole, Group operated isolator switch complete with manual & motor driven operating mechanism 1600A 3 Nos. ii) 3 Phase, Single Pole, Group operated maintenance earthing switch complete with manual operating mechanism- 2 Nos. 2 iii) 3 Phase, Single Pole, fast acting, fault make earthing switch complete with group operated manual & motor driven operating mechanism - 1 No. Current Transformer: 5 Core, Multi ratio, single phase current transformer 1200600/ 1-1- lA plus additional 2 cores of 1200/ 1-lA - f l Set) 3 Nos. Sure:e Arresters - ( 1 Set) 3 Nos. Cable end unit (Plug in type): 3 Phase, Single pole, Plug in type cable termination 1 Run for 1000 Sq.mm for each phase - 1 fSet) Bus Bar- Double bus arrangement: i) Main Bus - 2500A ii) Auxiliary Bus - 1600A Local Control cubicle for GIS module, gas monitoring device, barriers pressure switches etc as required. NOTE: The bus may be with single phase or 3 ohase enclosure. 220kV Line (0.H. line) Module: Nos 171.75 1.13 Each Module comprising of the following: SF6 circuit breaker Complete with operating Mechanism, 2000A, 1 Phase/3uhase - lNo 000032 SI. Name of the equipment No Unit Supply Rates in Rs Lakhs Erection rates in Rs Lakhs Nos 132.92 1.02 Disconnector: i) 3 Phase, Single Pole, Group operated isolator switch complete with manual & motor driven operating mechanism 1600A 3 Nos. ii) 3 Phase, Single Pole, Group operated maintenance earthing switch complete with manual operating mechanism- 2 Nos. iii) 3 Phase, Single Pole, fast acting, fault make earthing switch complete with group operated manual & motor driven operating mechanism - 1 No. Current Transformer: 5 Core, Multi ratio, single phase current transformer 1200600 / 1 - 1- lA plus additional 2 cores or 1200/ 1-lA - f l Set} 3 Nos. Single Phase SF6 duct & wall mounted SF6 to air bushing for outdoor connection or conductor of overhead line - as required. 3 Bus Bar- Double bus arrangement: eU Main Bus - 2500A eiU Auxiliary Bus - 1600A Local Control cubicle for GIS module, gas monitoring device, barriers pressure switches etc as required. NOTE: The bus may be with single phase or 3 ohase enclosure. 220kV Bus Coupler Module: Each module comprising or the following: SF6 circuit breaker Complete with operating Mechanism, 2000A, 1 Phase/3phase- 1 No. Disconnector: i) 3 Phase, Single Pole, Group operated isolator switch complete with manual & motor driven operating mechanism 1600A 2 Nos. ii) 3 Phase, Single Pole, Group operated maintenance earthing switch complete with manual operating mechanism- 2 Nos. Current Transformer: 3 Core, Multi ratio, single phase current transformer 1200600/ 1-1- lA plus additional 2 cores of 12001 1-lA - f l Set} 3 Nos. 00 0 0 3 3 Sl. Name of the equipment No 4 Bus Bar- Double bus arrangement: Main Bus - 2500A Local Control cubicle for GIS module, gas monitoring device, barriers pressure switches etc as required. NOTE: The. bus may be with single phase or 3 ohase enclosure. Transformer Module:(For 1 50MVA - 220kV Side) Unit Supply Rates in Rs Lakhs Erection rates in Rs Lakhs Nos 2 10.8 1.13 Nos. 88.29 0.92 Each module comprising or the following: SF6 circuit breaker Complete with operating Mechanism, 2000A, 1 Phase/3ohase - 1 No. Disconnector: i) 3 Phase, Single Pole, Group operated isolator switch complete with manual & motor driven operating mechanism 1600A 3 Nos. ii) 3 Phase, Single Pole, Group operated maintenance earthing switch complete with manual operating mechanism- 3 Nos. 5 Current Transformer: 3 Core, Multi ratio, single phase current transformer 600-300/ 1 1-lA plus additional 2 cores or 1200/ 1-lA f 1 Set) 3 Nos. Surge Arresters (To be provided at the end or SF6 ducts to be connected to SF6 Air bushing for Transformer bushing connection): 3Nos.l l setl Bus Bar- Double bus arrangement: il Main Bus - 2500A ii) Auxiliarv bus- 1600A Local Control cubicle for GIS module, gas monitoring device, barriers pressure switches etc as reauired. Single phase SF6 ducts & SF6 to Air bushing for outdoors connections - As required NOTE: The bus may be with single phase or 3 nhase enclosure. Transformer Module(For 150MVA - 66KV Side) : Each module comprising or the following: SF6 circuit breaker Complete with operating Mechanism, 2000A, 1 Phase/3uhase -1 No. �?>\ Ma� �� · :i"" i ·��� �-5 ) � � ::J C) \. 0A I \� o · Cl- �*.t . * ·�·P.T.C�-· -....;; -.._ ;;..- 0000 3 4 SI. Name of the equipment No Unit Supply Rates in Rs Lakhs Erection rates in Rs Lakhs 44.26 23.98 0.45 0.34 Disconnector: i) 3 Phase, Single Pole, Group operated isolator switch complete with manual & motor driven operating mechanism 1600A 3 Nos. ii) 3 Phase, Single Pole, Group operated maintenance earthing switch complete with manual operating mechanism- 3 Nos. Current Transformer: 3 Core, Multi ratio, single phase current transformer 16001000/ 1-1-lA - f l Set) 3 Nos. Surge Arresters (To be provided at the end of SF6 ducts to be connected to SF6 Air bushing for Transformer bushing connection): 3Nos I 1 set) Bus Bar- Double bus arrangement: i) Main Bus - 2500A ii) Auxiliary bus- 1600A Local Control cubicle for GIS module, gas monitoring device, barriers pressure switches etc as required. Single phase /three phase SF6 ducts & SF6 to Air bushing for outdoors connections As required NOTE: The bus and the equipmnets may be with single phase or 3 phase enclosure. 6 PT Module i) 220kV ( 1 for each bus) ii) 66kV ( 1 for each bus) Nos Each module comprising of the following: Disconnector: i) 3 Phase, Single Pole, Group operated isolator switch complete with manual & motor driven operating mechanism - 1600A for 220kV, 1250 A - For 66kV- 1No. · ii) 3 Phase, Single Pole, Group operated maintenance earthing switch complete with manual operating mechanism - 1 No. Potential Transformer: 3 Core, Multi ratio, sine:le phase potential transformer i) 220KVN 3/ l lOV/-./. 3-l lOV/ v 3-l lOV/ v 3 1 Set (3 Nos.) ii) 66KV/-../ 3 / l lOV/-../ 3- l lOVN 3-l lOVN 3 1 Set 13 Nos.) � 5 �� a. 0) o h o4• �* � ��·* .. _ 5 ..... ' 00 0 0 3 5 SI. Name of the equipment No Unit Supply Rates in Rs Lakhs Erection rates in Rs Lakhs Nos Nos 12.58 8. 17 0.45 0.34 Nos 1 0 1 . 18 0.92 Nos 104.03 2.41 Bus Bar- Double bus arrangement: i) Main Bus - 2500A ii) Auxiliary bus 1600 A - for 220kV iii) Auxiliary bus 1250 A - for 66kV Control cubicle for GIS module, gas monitoring device, barriers pressure switches etc as reauired. 7 8 Bus Maintenance earth switch 3 Phase, Single pole, Group operated maintenance earthing switch complete with manual operating mechanism - 1600 Amp i) 220kV ( 1 for each bus) ii) 66kV ( 1 for each bus) 66 kV Transformer Module (For 3 1.5 MVA) Each module comprising of the following: SF6 circuit breaker Complete with operating Mechanism, 1600A, 1 Phase I 3 Phase- 1 No. Disconnector: i) 3 Phase, Single Pole, Group operated isolator switch complete with manual & motor driven operating mechanism 1250A 2 Nos.. ii) 3 Phase; Single Pole, Group operated maintenance earthing switch complete with manual operating mechanism 2 Nos. 9 Current Transformer: 3 Core, Multi ratio, single phase current transformer 400-200 I 1-1-lA ( 1 set) - 3 Nos. Bus Bar-Single bus arrangement: Main Bus - 2000A Auxiliarv bus - 1250A Control cubicle for GIS module, gas monitoring device, .barriers pressure switches etc .. as reauired. Cable end unit (Plug in type): 3 Phase, Single pole, cable termination - 1 Run for 630 sa.mm for each phase - 1 set. 66 kV Line (U.G.Cable) Module Each modu,le comprising of the following: SF6 circuit breaker Complete with operating Mechanism, 1600A, 1 Phase I 3 Phase- 1 No. Disconne .. :(\etalMa� � �ra � .. �... k> '5 � � I °" o.-,,r'J 0 (1) Q) � � t) ' * � � ::r ��*� - 0 0 003 6 Sl. Name of the equipment No Unit Supply Rates in Rs Lakhs Erection rates in Rs Lakhs i) 3 Phase, Single Pole, Group operated isolator switch complete with manual & motor driven operating mechanism 1250A 2 Nos. ii) 3 Phase, Single Pole, Group operated maintenance earthing switch complete with manual operating mechanism - 2 Nos. iii) 3 Phase, Single pole, fast acting, fault make earthing switch complete with group operated manual & motor driven operating mechanism - 1 No. Current Transformer: 3 Core, Multi ratio, single phase current transformer 1200-800 I 1-1- lA - 1 set 13 Nos.) Sure:e Arresters - 1 set (3 Nos.) Cable end unit (Plug in type): 3 Phase, Single pole, cable termination - 1 Run for 630 I lOOOOsq.mm for each phase - 1 set. Bus Bar-Single bus arrangement: Main Bus - 2000A Auxiliarv bus - 1600A Control cubicle for GIS module, gas monitoring device, barriers pressure switches etc., as required. 10 66 kV Bus Sectionalising module comprising the following Disconnector: 3 Phase, Single pole, Group operated isolator switch complete with manual & motor driven operating mechanism 2000A 1 Nos. Bus Bar-Single bus arrangement: Main Bus - 2000A Nos 47.96 0.92 Nos 54.49 0.35 Control cubicle for GIS module, gas monitoring device, barriers pressure switches etc., as required. Note: The bus and the equipments may be with single phase or 3 phase enclosure. 1 1 PT Module II 66 kV Each module comprising of the following: Disconnector: 000 0 3 7 Sl. Name of the equipment No Unit Supply Rates in Rs Lakhs Erection rates in Rs Lakhs i) 3 Phase, Single pole, Group operated isolator switch complete with manual & motor driven operating mechanism 1250A For 66 kV - 1 No. ii) 3 Phase, Single Pole, Group operated maintenance earthing switch complete with manual operating mechanism - 1 No. Potential Transformer : 3 Core, Multi ratio, Single phase potential transformer 66kV voltage class- lset/ 3Nos Bus Bar-Single bus arrangement: Main Bus - 2000A Auxiliarv Bus 1250A. Control cubicle for GIS module, gas monitoring device, barriers, pressure switches etc .• as required. 22 Rates for supply of Hybrid switchgear: Hybrid SF6 gas insulated switch gear 40kA rating suitable for outdoor installation of 1) modular design with mounting structure Modules for single breaker scheme Nos 75.00 0.75 Each module comprising or the following: SF6 circuit breaker Complete with operating Mechanism, 1600A, 3phase - 1 No. Disconnector: i) 3 Phase, three Pole, Group operated isolator switch complete with manual & motor driven operating mechanism 1250A 2 Nos. - 1 No. on line side and lNo. On Bus side ii) 3 Phase, three Pole, Group operated maintenance earthing switch complete with manual/ motor driven operating mechanism 2 Nos. - 1 No. each on line side and 1 No. on Bus side. iii) 3 phase, single pole, fast acting, fault make earthing switch complete with group operated manual & motor driven operating mechanism - 1 No. on line side Note: Combined disconnector and earthing switch operated by means of a common driving mechanism is acceptable. 000 0 3 8 Sl. Name of the equipment No Unit Supply Rates in Rs Lakhs Erection rates in Rs Lakhs Module 1 10 1.1 Current Transformer: 3 Core, Multi ratio, single phase Ring type current transformer 1200-800 / 1-1-1-lA 1 set ( 3 Nos.) oositioned in the bushin2. SF6 to Air bushing made of Silicon Rubber, 1600A on both line side and Bus bar side 2sets f3 Nos. each l Local Control cubicle for Hybrid module, gas monitoring device, pressure switches etc as reauired. Hybrid SF6 gas insulated switch gear 40kA rating suitable for outdoor installation of 2) modular design of twin Breaker type with mounting structure - Modules Each module comprising of the following: SF6 circuit breaker Complete with operating Mechanism, 1600A, 3phase -2 No. Disconnector: i) 3 Phase, three Pole, Group operated isolator switch complete with manual & motor driven operating mechanism 1250A 2 Nos. - 1 No. on line side. ii) 3 Phase, three Pole, Group operated maintenance earthing switch complete with manual/ motor driven operating mechanism 2 Nos. - 1 No. each on line side . iii) 3 phase, single pole, fast acting, fault make earthing switch complete with group operated manual & motor driven operating mechanism -2 Nos.- 1 No. each on line side iv) 3 phase,three pole,group operated isolator switch complete with manual motor driven operating mechanism 1600A - lNo. On bus side (Common for both lines) v) 3 phase, three pole, group operated maintenance earthing switch complete with manual/ motor driven operating mechanism lNo. On Bus side (Common for both lines) Note: Combined disconnector and earthing switch operated by means of a common driving mechanism is acceptable. 000 0 3 1 Sl. Name of the equipment No Unit Supply Rates in Rs Lakhs Erection rates in Rs Lakhs Current Transformer: 3 Core, Multi ratio, single phase Ring type current transformer 1200-800 / 1-1-1-lA - 1 2 set ( 6 Nos.) positioned in the bushing. 3Nos each on line side SF6 to Air bushing made of Silicon Rubber, 1600A on both line side and Bus bar side 3sets (3 Nos. each on line side and 3 Nos.fCommonlon bus side) Local Control cubicle for Hybrid module, gas monitoring device, pressure switches etc as reauired. OOOO dO SI No. Particulars 23 HTLS Conductor with accessories a) Conductor and Earth wire HTLS Conductor Units Amount in Rs. Lakhs kms 9.25 b) Accessories for HTLS 1 Dead End Assembly,Single Tongue(W/Terminal) Each 0.8 2 Thermolign Suspension Assembly (Single) Each 0. 13 3 Splice (MSC) Each 0.9 4 Repair Rod Each 0. 14 5 Vibration dampers Each 0.07 6 Bus Bar socket No 0.25 000041 SI. No. Particulars Qty. Amount in Rs. 24 Hot Line Materials A Name of Hot Line Tools 1 All angular grounding clamps lNo 2 All angle players lNo 3 Epoxy glass bond patching kit lKg 4 Ball and socket adjuster lNo 5 Hand line hook lNo 10250 6650 3500 1880 890 6 Grip all clamp stick a) 12 Feet lNo b) 10 Feet lNo c) 8 Feet lNo d) 6 Feet lNo 18 170 17900 16640 14300 7 Epoxy glass ladder a) 18 Feet lNo b) 12 Feet lNo 126080 95300 8 Two pole strain carrier a) 12 Feet 2 Poles b) 10 Feet 2 Poles c) 8 Feet 2 Poles 9 Cum-a-long, crescent type lNo 384200 37 1400 361700 48500 10 Insulator cradle a) 10 Feet lset b) 8 Feet lset 1 1 Static ground tool lNo 12 Insulated oiler 8 Feet lNo 13 Pruning saw lNo 14 Flexible insulated rerich lNo 15 Rotary blade lNo 16 Ratchet wrench with universal lNo 17 Energized insulator tester lNo 18 C type grounding clamps lNo 19 Hex socket sets lset 20 All angular cog wrench lNo ft,�en�" 69300 60200 12050 14750 3500 18800 2600 10160 68300 440 14300 29060 Oi. � �, �'5&:-· ) OJ ::>'.> ., , .. (!) � . .... � +; 0 ->: KP:tc'v � OOOO d2 SI. No. Particulars Qty. 2 1 Cum-a-long hooks lNo 22 Extension chain lNo 23 Link stick of sizes a) 6 Feet lNo b) lNo 10 Feet 24 Metal stain insulator fork lNo 25 Pole hangers lNo 26 Snatch block 5/8 inch lNo 27 D.E spanners, full set lset 28 Poly deccron rope a) 5/8 inch 600Ft b) Y:a inch 600Ft Amount in Rs. 3680 1970 10700 14300 6920 440 268 10 8900 44000 30500 29 Poly propelene rope a) % inch 600Ft b) Y:ll inch 600Ft 30 Safety helmets 8Nos 3 1 Bionacular with case-500Mts range lNo 32 Bus bar grounding clamp lNo 33 Cross arm tool hanger lNo 34 Flexible rench head lNo 35 Hydralically operated cutter lNo 36 Hot stick storage tube lNo 37 Hot stick manual lNo 38 Insulated handles with pliers lNo 39 Safety belts lNo 40 Nylon Belt strap 7 Feet long lNo 41 Single pole strain carrier yokes lNo 42 Single trolley wheel with 2 Y2 inch pole clamp lNo 43 Conductor end yoke assembly lNo 44 Structure end yoke assembly lNo 45 Dead end sockets lNo 46 Bolted dead end clamp lNo 47 Pole clamps for two pole strain carrier lNo � � an � a � -' a. <.? � ) - <b � '=' o '• � iJ � � 1? � \;� k.PJP);· 27800 18800 530 20600 6740 2870 7 100 127700 10700 1700 5570 13670 1 1 150 134900 15300 130400 129500 8900 5300 6550 00 0 0 4 3 SI. No. Particulars Qty. 48 Take up trunions lNo 49 Tool for W-keys lNo Amount in Rs. 6 100 2240 50 Tower saddles a) 1 %1 inch lNo b) 2 inch lNo c) 2 Y2 inch lNo 5 1 Tower and :flat face grounding clamps lNo 52 Teleheight lNo 53 Two triple sheave pulley block- Y2 inch lset 54 Two double sheave pulley block- 3 / 8 inch lset 12500 16100 19070 4040 10700 31400 37070 55 Universal pole with heads a) 12 Feet lNo b) 10 Feet lNo c) 8 Feet lNo 56 Universal adopter lNo 57 Hot stick tester lNo B 9530 8810 800 102500 Thermovision camera 1 Sub-station with a range of 10- 12mts 2 Transmission lines with range of 20mts c 9980 Global Positionine: System (GPS) lNo 670090 lNo 813600 lNo 15000 000044 PART II SCHEDULE OF RATES FOR LABOUR OF MAJOR WORKS Amount in Rs. SI No. Description Unit 220 kV 1 A 1 10 kV 66 kV 33 kV Detailed Surveying on Turn-Key: i) Reconnoitary Survey-cum-walk over Survey along with K.P.T.C. Ltd., Staff to determine the feasible route of the line on topo sheet. An alternate route if available should be indicated. The route of the line is to be indicated and got approved by the competent authority( Rates include the cost of Toposheet and Transportation) al Hillv terrain bl Plain terrain KM KM 1329 1259 668 629 KM KM 6419 4290 3202 2 137 ii) Detailed Survey, fixing anchor points and taking levels at 20 Mtrs intervals, drawing route profile on Graph paper indicating geographical features like Nalas, Rivers, Gardens, P&T Lines, Railway-crossings etc., and enroute villages furnishing geoco-ordinates of each location with survey nos of the lands through which the line is passing duly covering the corridor proposed to be cleared . al Hillv terrain bl Plain terrain Remarks:-In case of detailed survey of existing line for preparation of schedules to facilitate placing of proposals before PTCC, 50% of the above costs are to be adopted. 0000 4 5 Amount in Rs. SI No. Description Unit 66 kV 220 kV iii) Fixing marking stones with approved marks including painting above the ground level and Yellow Lettering and marking the direction of incoming line and out going lines are to be clearly marked on the top with red colour. If the distance between two anchor points is more than 1 KM, one more directional stone is to be fixed. So also for the road crossing, railway crossing and nala crossing for all on both the sides. Per Stone iv) Burgie details for identification for Per Anchor all Anchor towers with existing Tower permanent marks like poles, telephone lines, buildings, etc., v) Excavation for soil classification a) Excavation of soil 1.2 Mtrs. x 1.2 Mtrs. up to a depth of 3 Mtrs. or up to hard rock is reached which ever is less (Applicable for soil classification purpose for 400 kV & 220 kV lines only) b) Excavation of soil 1 .2 Mtrs x 1.2 Mtrs. up to depth of 2.5 Mtrs. or up to hard rock is reached which ever is less(Applicable to 1 10 kV & 66 kV lines) The excavation of trial pits shall be retricted to one pit for every Km and part there off. vi) Conductine: soil resistivitv tests vii) Clearing of bushes, tree branches of trees crops and shrubs wherever encountered for detailed survey to enroute the corridor width of 3 Mtrs (including viewing for f°lXing anchor towers etc . \ al Hillv terrain bl Plain terrain I 33 kV 319 288 CMT Rates for different soils encountered as per actual soil condition applicable for transmission line (Ref-item 3A ) Per Test 552 Per Km Per Km 956 637 . 0 0004 :3 Amount in Rs. SI No. Description Unit I 220 kV I 1 10 kV viii) a) Submission of reports in the form of good binding including the preparation of sketches for burgie details for each anchor points, scheduling of line details, S.R. values, soil classification reports tower schedule, abstract of towers etc., complete. Per set 194 b) Drawing the route profile on graph sheet including geographic features like nala's, rivers, gardens, P&T lines, railway crossings etc., inclusive of all stationeries (Normal requirement is 5 Sets) Per Km 194 ixl Preuaration of Schedules: a) PTCC Proposal : Containing PTCC questionaire, topo sheet extracts with marking of the proposed line, S.R. Report, tower sketch, station single line diagram etc.,(30 Conies/Setl b) Railway Crossing proposal with drawing are inclusive of graph sheets and other stationery materials, labour etc. 1 10 Setsl I I Per set 769 Per Crossing 769 c) Tree Schedule Containing the details like name of tree, girth size of tree, distance from central line of the alignment, approximate height of the tree etc., complete Per Hectare 552 d) Forest proposals : Inclusive of all works like fixing of stones at every 20 Mtrs in the centre line and both ends of the corridor, painting of each tree after chipping, writing the numbers on the tree, taking girth size of all the trees coming in the corridor at 1 Mtr height from GL, approximate height of the tree and forest clearance proposals etc., complete ( 1 0 sets) Per Km 3590 I 66 kV 33 kV I Note: This applies to forest area only B Check Survey by using their own !Eouiument al Hillv terrain bl Plain Terrain Per Km Per Km 3202 2137 1593 1065 . 000047 Amount in Rs. SI No. Description Unit 220 kV 2 1 10 kV 66 kV 33 kV A Taking block levels for Sub-stations: a) Running Peripheral Theodolite traverse along periphery and coordinating and heightening of all comers/turning points, establishing permanent co-ordinate axis formation of grids at SOM intervals for northing and easting with reference to already established permanent co�ordinate axis levels at SO M grid intersection for preparing plot plan of the entire area with contours. Including existing structure location. Hectare 106S b) Establishing datum level and bench marks at every lOOM/SOM intervals both longitudinal and laterally and all comers/turning points with stone pillars of size not less than 0.2Mx2Mxl .OM buried on the ground and exposed top engraved for painting RL, and co-ordinates of that Nos. 106S c) Taking level at SM/ suitable grid interval in the sub-station area for l nlottinll block levels. contour man. Nos. 23 Per Project 10646 , ... ..:. ... + d) Preparation of CAD drawings, generating the contours using appropriate software and submission of 6 sets of blue prints and one tracing sheet (original) and one soft copy etc. Complete. e) Furnishing cutting and itlling quantities using appropriate software Per Project for earth work calculation. 3194 f) Super imposing GA drawings on contour maps in Co-ordination with KPTCL engineers and supply of 12 sets of blue print drawings etc., comnlete. 8S17 Per Project 00004 8 Amount in Rs. SI No. B Description Unit 220 kV 1 10 kV 66 kV 33 kV Geo Technical Investigations: a) Making 150mm nominal diameter bore holes at various locations in soil using suitable approved method of boring including, cleaning providing Bore holes at interval and at change of strata, collections of water samples, observation such as ground water etc., Collection of undisturbed soil samples at every 2.0M/3.0 M interval and at change of strata, transporation of all the collected samples to the laboratory and back filling of bore holes on completion of the work, complete as per specification and instruction of the 6.0M below natural ground level or refusal strata. Per Mtr 1593 i) Bulk density and moisture content Each 637 ii) Sieve analysis iii) Hydrometer Analysis iv) Liquid limit and plastic limit v) Shrinkage limits vi) Specific gravity vii) Standard proctor density test viiil Swell pressure ix) Free swell index Each Each Each Each Each Each Each Each 637 637 637 746 746 746 855 855 x) Uncombined Compressive strength Each 855 xi) Triaxial shear test xii) One dimensional consolidation test xiii)California bearing ratio c) Submitting final report in 6 copies including all field records and laboratory test results, graphs and recommendations etc., complete as 1 ner snecifications. Each 855 Each 855 Each 855 Per Job 12776 b) Conducting various laboratory tests on soil samples at approved laboratory including preparation of soil samples to determinate of soil, all complete as per specification. Note: Laboratory identified shall be approved by KPTCL not below the rank of EE(Civil) 0 0 00 4 9 Amount in Rs. SI No. Description Unit 220 kV 1 10 kV 66 kV 33 kV Note: The above rates are inclusive of mobilization of Plant Equipment & Materials for , Topographical survey, block leveling and Geotechnical investigation works, and Demobilization. No extra rate is admisible for mobilization & Demobilization 3 - Excavation for station structure: 1) Corresponding rates in KPWD SR as mentioned against each classification below shall be adopted. 2) Area weightages applicable for the respective areas as per Latest KPWD SR shall be allowed to arrive at final rate. 3) Extra for excavation under water conditions and/ or foul conditions including bailing/pumping out, removing slush add 20% of the rate of the respective rate on account of slow progress of work under these conditions. ( The extra percentage indicated here shall be as indicated in the relevant KPWD SR ) Excavation of pits as per specifications for lattice type of station structures, Tr. Plinth, control panels, mounting structures for breakers, CT's, PT's Isolators, LA's etc., Excavation of trnches for control cables, U.G. Cables, Groundmat etc., - i) Normal Soil --- A ii) B�C. Soil iii) Partially Submerged soil iv) Fullv submerged soil v) Wet black cotton soil CMT CMT CMT CMT CMT - Latest Latest Latest Latest KPWD SR Rate for ordinary soil KPWD SR Rate for ordinary soil KPWD SR Rate for ordinary soil KPWD SR Rate for ordinary soil vi) Dry fissured/Ordinary rock CMT Rate for ordinary rock (without blasting) of Latest KPWD SR vii) Latterite soil CMT Rate for ordinary rock (without blasting) of Latest KPWD SR viii) Hard rock with blasting/Hard latterite CMT Rate for hard rock (with blasting) of Latest KPWD SR -- - Latest KPWD SR Rate for hard soil Note 1 : For Excavation purposes measurement shall be as per actuals. -- Note 2 : For foundation purposes predominant soil shall be considered. 0 0 0 050 Amount in Rs. SI No. Description Unit 220 kV ,___ ,___ t--t--t--t--- - - ,____ 4 - Excavation IFor Tr. Line Tower} i) Normal Soil ii) B.C. Soil iii) Partially Submere:ed soil iv) Fully submere:ed soil B v) Wet black cotton soil vi) Drv fissured/Ordinarv rock viit Latterite soil viii) Hard rock with blasting/Hard latterite Back Filline: : i) Back filling with excavated earth available near the tower and consolidation layer by layer of 150 mm depth with adequate quantity of water. ii) Supplying and back filling with c external hard murrum soil with proper consolidation including lead and lift. Note: This item is applicable only when Black cotton soil, wet black cotton soil, dry fissured rock, ordinary rock, Hard rock are encountered. Concreting and curing (For Both Transmission lines and station structures} CMT CMT CMT CMT CMT CMT CMT 1 10 kV 33 kV 66 kV (Rates as per item3-A + 50% extra) CMT + CMT Rates as per Latest KPWD SR extra CMT Rates as per Latest KPWD SR + 10% extra a) Concreting and curing as per specifications including the cost of materials, T&P materials and labour charges with all lead and lift, for lattice type station structures, Tr. Plinth, control panels, mounting structures for Breakers, CT's PT's Isolators, LA's, etc., 10% 1 ) Corresponding rates in Latest KPWD SR as mentioned against each classification shall be adopted. 2) For the above basic rate add applicable area weightage as per Latest KPWD SR. - i) 1:4:8 Concrete (M 7.5) CMT Rate under plain concrete for foundation of Latest KPWD SR. ii) 1:3:6 Concrete (M- 10) CMT Rates under basement of Latest KPWD SR iii) 1:2:4 Concrete (M- 1 5) CMT Rate under raft foundation of Latest KPWD SR ,___ - D - . 000051 SI No. Amount in Rs. Description Unit 220 kV iv) 1 :1 .5:3 Concrete (M-20) b) Concreting and curing as per specifications including the cost of materials, T&P materials and labour charges with all lead and lift for Transmission line Towers. 1 10 kV 66 kV 33 kV CMT Rate under raft foundation of Latest KPWD SR CMT For arriving at the rates for concrete items for transmission lines, add 25% weightage to the basic rates of different propotions of concrete proposed above. Kgs For sub-station works, rate as per KPWD SR and for Transmission line works, add 10% extra MT 249 Note : a) Extra as indicated in the relevant KPWD SR may be allowed for providing concrete in watery situations including cost of bailing out water and removing slush. b) Only machine mixing for concreting is to be used. c) Jelly to be used is 20 mm. and down size for 1 : 1 .5:3, 1 :2:4 & 1 :3:6 concrete and 40mm and down size for CC 1 :4:8. Providing and fabricating TMT steel reinforcement including straightening cutting, bending hooking, lapping and I or welding wherever required placing in position tieing with binding wire and E anchoring to the adjoining members wherever necessary including laps and wastages etc., complete as per design, and specification and directions (Laps and wastages not to be measured and paid) 5 Towers a) Sorting of tower parts made of fabricated an2'.le iron. b) setting up of stubs templates and aligning dismantling and transportation of templates from one location to another location c) Assembling and erection of towers including tightening of bolts and nuts including loading, unloading at store and site (Including the Wt. of stubs). Per Locn MT 497 45 1 373 1811 00005 2 Amount in Rs. Sl No. Description Unit 220 kV 1 10 kV d) Rivetting of tower bolt ends by heating using dry-Acetylene gas and hammering to destroy threads so as to make the tower members theft proof (Bolts at nodal points only to be selected and rivetted up to hieght of bottom cross arm, as per the directions of the field engineer) Per Bolt 9 e) Welding of bolts and nuts Per Bolt 9 Per set 1772 Rmtr 33 Nos Nos Set ( 3 Nos.) Nos 34 34 66 kV 33 kV Note : For tower erections requiring shutdown 2So/o above S.R. for item Sc to Se only are to be adopted. 6 Suuulying and fixing A.C. devices : a) Supplying and fixing G.I. Angle iron 4Sx4SxS mm ( lmtr length) with cleats, bolt & nuts as per specification and fixing above O.S mtrs length each at inner and outer surface of the tower to facilitate runnfna nf' ,_ ,.,._.,1 wf1'� b) Supplying and fixing barbed wire as uer specification Fixing of Boards a) Fixing Danger Board b ) Fixing Number Plate __ 7 c) Fixing Phase Plate 8 d) Fixing Circuit plate Stringing of Conductor without allowing the conductor to touch the ground and without damaging the conductor. 103 34 a) Paving out conductor from anchor to anchor normally spaced at s spans with 4 tangent towers in between, including providing stays at each anchor points and jointing of conductors, hoisting and fixing of insulator string, armour rods, vibration dampers, including the cost of T&P materials like comealong, wire ropes, pulley, rollers, suspension clamps, compression jointing machines with bits, drum stands, manila ropes, truckker and jeep etc., (Rate for 1 route KM of single conductor) 000 0 5 3 SI No. Amount in Rs. Description i) For hilly terrian Unit KM 220 kV 1 10 kV 17547 8774 66 kV I 33 kV 7972 with coyote ACSR r-- 7972 with Rabbit ACSR on Towers r-- 2191 with Rabbit ACSR on RCC Poles ii) For Plain terrian KM 13498 6264 5844 with coyote ACSR r-- 2921 with Rabbit ACSR on Towers r-- 1756 with Rabbit ACSR on RCC Poles b) I) Stringing of ground conductor as above i) For hilly terrian ii) For plain terrian KM KM 5852 4383 4383 3505 3901 2922 Note: Conductors normally used are: i) 220kV - Drake and AAAC Moose ii) 1 lOkV - Lynx and Drake iii) 66 kV- Coyote and Drake II) For shut down works 50% more than the above rates of the work (This is applicable to shut down of 33kV and above lines only. l lkV & L.T. lines shut down not included) 50% more above the rates specified for normal works is admissible for shut down works of 33kV and above lines, CTs, PTs, LAs only. This is not applicable for l lkV & L.T line shut down works. 000 0 5 4 SI No. Amount in Rs. Description Unit 220 kV III) For National Highway crossing railway crossing and State highway crossine: IV) River crossing exceeding more than 20% of the normal span. This is applicable to stringing the lines running parallel to a charged circuit also. 9 I I uo kV I 66 kV 15% I 33 kV corresponding normal span stringing rate + 30 % extra V) Rates for 33 kV Stringing are separately indicated under SR for 33 kV works.(Crossing charges should not be allowed when shut down char2'es are admittedl VI)Restoration of power supply due to dislocation of existing transmission line towers These Rates are applicable only when total Length of the entire Line is less than 3 suans. 75% A) Stringing of conductors in special conditions where normal 5 spans between anchor to anchor are not encountered, whereas anchors are provided at single/two/three spans with average span intervals of 267 /320 Mtrs, (rate for spans of single conductor) U For hillv terrian a) Anchoring single span upto 320 mtrs. 1 Span 9768 4873 4173 with coyote ACSR 2044 with Rabbit ACSR b) Anchoring 2 span interval upto 640 mtrs with 1 tangent tower only 2 Spans 12 177 6077 5175 with coyote ACSR 2471 with Rabbit ACSR c) Anchoring 3 span interval up to 960 mtrs with two tangent towers only 3 Spans 14649 7320 6069 with Coyote ACSR 000055 Amount in Rs. SI No. Description Unit 220 kV 1 10 kV 66 kV 33 kV 2921 with Rabbit ACSR iii For plain terrian a) Anchoring single span up to 320 Mtrs 1 Span 75 15 3404 3132 with coyote ACSR 1508 with Rabbit ACSR b) Anchoring 2 span interval upto 640 Mtrs with 1 tangent tower only 2 Spans 9388 4367 40 10 with coyote ACSR 1850 with Rabbit ACSR c) Anchoring 3 span interval upto 960 Mtrs with two tangent towers only 3 Spans 1 1260 5261 4491.63 with Coyote ACSR 2169 with Rabbit ACSR B) Stringing of ground conductor as above il for hillv terrian a) Anchoring single span upto 320 mtrs 1 Span 3233 2425 2 106 2 Spans 4049 3046 2510 3 Spans 4873 3660 2984 1 Span 2448 1958 1585 b) Anchoring 2 span interval upto 640 Mtrs with 1 tangent tower only 2 Spans 3062 2425 1927 c) Anchoring 3 span interval upto 960 Mtrs with two tangent towers only 3 Spans 3684 2937 2269 b) Anchoring 2 span interval upto 640 mtrs with 1 tangent tower only c) Anchoring 3 Span interval upto 960 mtrs with two tangent towers onlv iii For plain terrian a) Anchoring single span upto 320 Mtrs 000056 SI No. Amount in Rs. Description Unit 220 kV 1 10 kV 66 kV 33 kV Note: 1) Conductors normally used are i) 220kV - Drake and AAAC Moose ii) l lOkV - Lynx and Drake iiil 66 kV- Covote and Drake 2) For Shut down works 50% more above the normal rates of respective works (This is applicable to shut down of 33kV and above lines only. l lkV & LT line shut down works not included). Rates for Short span stringing in Normal length of the line of more II than 3 spans comprising of short snans A) Stringing of conductors in special conditions where normal 5 spans between anchor to anchor are not encountered, where as anchors are provided at single/two/three spans with average span intervals of 275/320 Mtrs, (rate for spans of single conductor) U For hillv terrian a) Anchoring single span upto 320 Mtrs 1 Span 1469 730 62 1 with coyote ACSR 304 with Rabbit ACSR b) Anchoring 2 span interval upto 640 Mtrs with 1 tangent tower only 2 Spans 2432 1212 1033 with Coyote ACSR 498 with Rabbit ACSR c) Anchoring 3 Span interval up to 960 Mtrs with two tangent towers only 3 Spans 3660 1834 1515 with Coyote ACSR 73 1 with Rabbit ACSR iil For Plain terrian 00 0 0 5 7 SI No. Amount in Rs. Description a) Anchoring single span upto 320 Mtrs Unit 1 Span 220 kV 1 10 kV 1 127 513 66 kV I 33 kV 467 with Coyote ACSR 226 with Rabbit ACSR b) Anchoring 2 span interval upto 640 Mtrs with 1 tangent tower only 2 Spans 1881 870 762 with Coyote ACSR 373 with Rabbit ACSR c) Anchoring 3 Span interval upto 960 Mtrs with two tangent towers only 3 Spans 28 13 1313 1 127 with Coyote ACSR 567 with Rabbit ACSR B) Stringing of ground conductor as above ii for hillv terrian a) Anchoring Single span upto 320 Mtrs b) Anchoring 2 Span interval upto 640 Mtrs with 1 tane:ent tower onlv c) Anchoring 3 span interval upto 960 mtrs with two tangent towers onlv ii) For Plain terrian a) Anchoring single span upto 320 Mtrs 10 1 Span 482 365 319 2 Spans 808 606 505 3 Spans 1220 91 7 746 1 Span 365 295 241 b) Anchoring 2 span interval upto 640 Mtrs with 1 tangent tower only 2 Spans 614 614 389 c) Anchoring 3 span interval upto 960 Mtrs with two tangent towers only 3 Spans 1041 738 567 A) Clearing of bushes, branches of tree & Crops for erection of tower & Stringing of line for full corridor width. al In thin June:le bl In thick Junl?le Per Km Per Km 2339 3513 000053 SI No. Amount in Rs. Description Unit 66 kV 220 kV c) Removing grass/vegitation,bushes in station yard/ premises including disposal of the same. B) a) Cutting of trees of different girths including cutting of trunks, branches and removal of stumps stacking of serviceable materials earth filling in the depressions/pit, labour charges complete as per 1::necifications b) Transportation of wood to the desired destination as per KPTCL directions c) Clearing and grubbing land including uprooting rank vegetation, grass, bush, shrubs, saplings and trees of girth up to 300mm by manual means in area of light jungle, removal of stumps, disposal of unserviceable materials, stacking of serviceable materials, labour charges complete as per specifications. 11 I Sq. Mtr 8 Nos As per applicable KPWD SR Cum Rate as per forest SR Sqm As per applicable KPWD SR 33 kV Material + Labour Grounding of towers/Equipments a) Grounding of towers including cost of 40mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 Mtrs length as per specifications, with 50X6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges. Set 2246+62 1 b) Grounding of towers/ Equipments excluding the cost of G.I. Pipe/C.I. Pipe as per specifications with 50X6 mm G.I. Flat 3 Mtr Long (to be supplied departmentally). But salt & Charcoal to be supplied by contractor. The rates include excavation charges. Set 589+621 c) Grounding of equipments by providing cast iron pipe of lOOmm ID 13mm thickness, 2. 75 Mtrs long with 2 part clamp out of G.1.Flat 50X6mm continuously welded alround the pipe using cast iron welding electrodes as per drawing including the cost of excavation (All materials to be supplied by the contractor) Set 5500+ 1500 00005 9 Amount in Rs. Sl No. 12 13 Description Note : All the leads from earthmat & equipment should be connected to earth electrode through the GI Flat 50 x 6 mm of suitable length and welded as ner snecifications. Supplying and fixing of counter poise earthing with G.I. Stranded wire where hard rock is encountered as per specifications. (including excavation char2esl. Station Structures a) Erection, assembly and alignment of Station structure as per the directions of site Engineer. 14 b) Erection, alignment & assembly of fabricated steel lattice structure, pedestal structures & Mounting structures, for G.O.S., CTs, PTs LAs etc.. Erection of Transformers a) Moving the Transformer to the plinth. Maximum allowable distance is 50 Mtrs. (More than 50 Mtrs. approval of the D(T) has to be obtainedI b) i) Assembly of Transformer parts like bushings, radiators, filling oil into Tr. etc., for the total wt. of the Tr. ii) Filling oil to the power Tr. Conservator and radiator (for maintenance purpose onlvl For 5 MVA to 20MVA Tr. For 50 MVA & above with vaccum iii) Filtration of oil using filter set of the contractor, to bring the insulation value to I.E. Soecifications. iv) Filtering Oil as above but with the filter set supplied by the board. c) Wiring of Transformer marshalling box, bucholtz relay, fbdng Thermometer, OLTC upto control panel and assisting in testing and commissioning by RT/MT/Firm en'1'ineers ii 5MVA to 6.3/8 MVA Tr. iii lOMVA to 20MVA Tr. iii) Above 20 MVA Tr. a ;:I� (!) <Zi :::> 0 ( \ 041 0 * ";; � &\ �·I '1 � I; ) :>..-.. � / Unit 220 kV I 1 10 kV I 66 kV Per Loe 1 599+ 1430 MT 2 106 MT 1593 Per MT/Mtr 34 MT 762 Litre Litre 2 2 Litre 3 Litre 2 L/S L/S L/S 35 13 7025 1 17 1 1 I 33 kV 000060 Sl No. Description Amount in Rs. Unit 220 kV 15 16 17 Fabrication of Transformer railing and embedding in Transformer plinth. (Rails to be supplied by the Corooration' Fixine: of H. T. fuse units & wiring 18 JI. R�li'R - 699 Per Set 816 100/ 150 MVA 66 kV 33 kV 12.5/2 0/31.5 8 / 10 MVA MVA 5/6.3 MVA 1 1835 47340 9862 6575 39448 26300 59 17 23668 Per Set 124 1 1 9932 7445 4966 set 2437 1989 1492 995 set 7671 59 17 59 17 591 7 set 30684 23668 23668 23668 Set ( 3 Nos.) 6209 Lump Sum for Each � , __ Erection of Breakers a) Breaker Erection, assembly, alignment & interpole wiring of breakers with its connected equipments including movement from the point of unloading to the noint of erection. b) Assisting in Testing and Commissionine: c) Testing & Commissioning: Wiring:Identification, ferruling, crimping and termination of wires in Breaker & Wiring up to control 1 nanel/Relav oanels. Testing: Test for insulation level, gas leakage, Testing for travel time, Trip and close timings. Local Trip close test, Remote trip and close test, Tripping through relays, operation of interlocks etc., 19 L/S Testing & Commissioning of Power Transformers a. Inspection of wires and Ferrules. Inspection of wiring of Protective Devices, Cooling fans, Oil flow Pumns. OLTC. RTCC b.Testing: 1 . Ratio Test 2. SC test 3. Excitation test 4. Magnetic Balance test 5. Vector group test 6. Induced High voltage test 7. OLTC operation 8. Protective Devices operation Checks 9. Stability Checks: For Differential 1 10 kV Erection of CTs and PTs a) Erection of CTs and PTs and wiring including movement from the point of unloading to the point of erection. 4966 2479 1243 00006 1 SI No. Amount in Rs. Description b) Assisting'in Testing and Commissionine: c) Testing & Commissioning of Current transformers: Wiring:Inspection of wiring,Ferruling, Crimping of lugs, Connections up to marshalling box & Control panel. Testing and commissioning of CTs: Insulation, Polarity, Ratio, Excitation. d) Testing & Commissioning of Potential transformers: Wiring:Inspection of wiring,Ferruling, Crimping of lugs, Connections up to marshalling box & Control panel. 20 21 Testing and commissioning of PTs: Insulation, Polarity, Ratio, Excitation. Erection, Testing & Commissioning of NCTs a) Erection of NCTs including movement from the point of unloading to the point of erection with e:roundine: connections b) Assisting in Testing and Commissionine: Erection of Isolators a) Assembly, Errection alignment and wiring including movement from the point of unloading to the point of erection. i) Upright ii) under hung b) Assisting in Testing and Commissioning U Upright ii) under hung Unit 220 kV 1 10 kV 66 kV 33 kV f 3 Nos.) 746 622 497 373 Set ( 3 Nos.) 3945 1972 1972 1972 Set ( 3 Nos.) 15780 7888 7888 7888 Set ( 3 Nos.) 1972 1972 1972 1972 Set ( 3 Nos.) 7888 7888 7888 7888 Set 1989 1578 746 365 Set 85 85 85 47 Set Set 6209 7453 4966 6209 2487 3730 746 Set Set 622 746 497 622 249 373 78 Set Note: 1) Assisting in testing and commissioning for item no. 17 to 19 means contractors should provide labourers for testing and commissioning by RT /MT /Firm engineers. 2) Testing & Commissioning in item 17 & 20 means the testing will be carried out by the firms themself using their own testing equipments & staff in presence of the MRT staff who will witness the tests. 0 0 0 0'6 2 Amount in Rs. Sl No. 22 23 24 25 Description Erection of Li2htninl! Arrestors Erection of Lightning arrestors and wiring including movement from the point of unloading to the point of erection Fixine: of Solid Core insulator Test & Commissioning: Capacitor Bank with reactors Control Cables and U.G. Cables a) Formation of Cable Duct i) Burnt brick/size stone/RCC Cable duct including form box, back f°llling the sides, removing the excess escavated soil, duct covering with RCC slabs. ii) Supplying 300 mm dia 1 . 5'.' to 2" thick RCC Hume pipes including loading unloading, and transportation charges and laying at required level and gradient as per the direction of field engineer Unit 220 kV 1 10 kV 66 kV 33 kV Set 1243 746 373 187 Per Stack 249 194 148 62 15325 15325 15325 Each Cmt As per Latest KPWD electrical SR applicable to respective areas. As per Latest KPWD electrical SR applicable to respective areas. b) Providing, laying and jointing PVC pipes conforming to IS 4085-1960, & 7634- 1975, and approved makes with necessary specials such as collars, bends, Elbows, Tee, nipples, plugs with cuts and threads using jointing ring with solutions, wherever necessary as per the directions of the field engineer including all lead and lift. As per Latest KPWD electrical SR applicable to respective areas. 25 mm dia (outer) 2mm to 2.5mm thick Mtr As per Latest KPWD electrical SR applicable to respective areas. 32 mm dia (outer) 2mm to 2.Smm thick Mtr As per Latest KPWD electrical SR applicable to respective areas. 63 mm dia (outer) 2mm to 2 .5mm thick Mtr As per Latest KPWD electrical SR applicable to respective areas. r, r"' '' 0 0 C· ' ' b IV \ \,,/ SI No. Amount in Rs. Description Unit 220 kV 1 10 kV 66 kV 33 kV 75 mm dia (outer) 2mm to 2.5mm thick Mtr As per Latest KPWD electrical SR applicable to respective areas. 90 mm dia (outer) 2mm to 2.5mm thick Mtr As per Latest KPWD electrical SR applicable to respective areas. 1 10 mm dia (outer) 2mm to 2.5mm thick Mtr As per Latest KPWD electrical SR applicable to respective areas. 140 mm dia (outer) 2mm to 2.5mm thick Mtr As per Latest KPWD electrical SR applicable to respective areas. 160 mm dia (outer) 2mm to 2.5mm thick Mtr As per Latest KPWD electrical SR applicable to respective areas. Rmtr 225+156 Rmtr 165+ 105 Rmtr 7 Rmtr 39 Rmtr 39 Rmtr 39 Rmtr 39 Nos 1725 Nos 2246 c) Supplying & Laying cable trays including welding fixing of supports 26 i) Cable tray of 600mm width (Suitable for cable ducts of A, B & C tvoel ii) Cable tray of 300mm width (Suitable for cable duct of D tvoel d) Laying of control cables from eauipments to control oanels. e) Laying of 1 1 kV cables in existing trench/G.I. Pipe/Stoneware pipe/RCC Hume pipe using wooden I aluminium rollers as directed by KPTCL staff. i) Cables of Sizes 3Cx95 to 3Cx150 sq mm ii) Cables of sizes 3Cx185 to 3Cx240samm iii)· Cables of sizes 3Cx300 to 3Cx400 samm iv) Cables of sizes 1Cx630 to lCxlOOO sqmm f) Fixing of pot heads for HT cable onlv i) Epoxy type ii) Heat Shrinkable/Cold Shrinkable /Pushon Control Panels 00 0 0 6 :1 Amount in Rs. SI No. Description a) Erection of control panel, auxilary panel, carrier cabinet etc., alignment and f"'ixing properly to foundation base including movement from the point of unloading to the point of erection. b) Wiring & assisting in testing and commissionine: of nanel. c) Test & Commissioning: i) C& R Panels Wirine: & Testine:: Wiring of C&R panels: Identification, ferruling, crimping, termination of wires in C&R panels. Testing of C&R panels: Testing for insulation level Testing of relays, control operations for closing tripping etc., interlock. Alarm Annunciation & Indication Checks. ii) Sychronising Trolley/Panel: Wiring, Testing, Calibration of meters & Testine: for ooeration iii) Bus Bar Protection Panel wiring & testine:: Unit Per Panel 1 10 kV 66 kV 33 kV 3108 3108 2487 2487 59 17 59 17 23668 23668 23668 3886 Per Panel Per Panel 7835 Per Panel 31340 Each 1 1 536 59 17 Each Wiring: Identification, ferruling, crimping, termination of wires in Bus Bar protection panel. Rs.2307 upto 3 Bays & Rs.986 for each additional Bay. Rs.9229 upto 3 Bays & Rs.3944 for each additional Bay. Testing: 1 .Testing of relays. 2. Stability test. 27 220 kV 1 1 kV Switche:ear a) Erection, alignment and fixing to the foundation, indoorI outdoor 1 lkV switchgear Panel/unit including movement from the point of unloading to the point of erection. i) 1 lkV Indoor/ out door switche:ear ii) l lkV Kiosk b) Wiring & assisting in testing & Commissionine: fl��, ��f� j \ �' \-:;! � � \�)'� �u oho -� '" · i .J:.' "1'..':' t Per uanel Per Panel 1492 1243 000 0 6 5 Amount in Rs. Sl No. Description i) 1 1 kV indoorI outdoor switchgear Unit 220 kV 1 10 kV 66 kV 33 kV Per Panel 497 ii) 1 lkV Kiosk c) Testing & Commissioning: Wiring: Identification of wires, Ferruling Crimping & Termination of wires for annunciation, etc., Testing of Relays, CTs, PTs, & Breaker for oneration. i) For indoorI outdoor panel comnrisinll of 21+SF+ lBC+ 1AP3 Per Panel 497 Per set 65503 ii) For single l lkV panel indoor type Each 13098 Each 6549 Each 13098 Each 10009 Main bus/cross bus (all the three phases in a segment) of using Falcon/Drake/Lynx/Coyotesingle/double conductors with fixing of insulator spacers, levelling of string conductors to the required height above the equipment, including providing jumps to interconnect different segments of the main bus.(Spacers to be used only for Double Conductor) Per Bay Main/Cross bus with spacers (Spacers to be utilised only for Double Conductor) using i) Quad Moose ACSR ii) Falcon single conductor- 6901/- iii) Falcon double conductor- 10347 /- iv) Single drake conductor- 5519/- v) Double drake conductor - 8282 /- vi) Single Lynx conductor -459 1/- vii) Single Coyote-conductor- 4591 /- Groundmat a) Laying of M.S. Flats, welding, applying ACB paint to welded portion and covering with sodium bentonite clav Rmtr 25 iii) For additional 1 lkV panel (indoor tvoe) iv) For single l lkV panel outdoor tvoe/Kiosk v) For each additional l l kV panel out door tvoe/Kiosk Note:Assisting in testing & Commissioning for item 22,24& 23 means contractors should provide labourers for wiring & Commissioning by RT/MT/Firm Engineers. 28 29 Busbar Formation 00( . . . ' '-' ·-· - 0 00065 Amount in Rs. Sl No. Description Unit 220 kV b) (i) Supplying and laying of MS flats of vartious sizes, welding and applying ACB paint to welded portion and covering with sodium bentonite clay, as per the drawing/standard specifications and consolidation. o I kV 66 kV Rmtr 50x6-273 50x8-291 75xl2-566 75x6-505 75x8-535 Rmtr 50x6- 135 50x8-152 75xl2-429 75x6-367 75x8-395 c) Grounding of equipment with 50x6mm G.I. Flat and connecting Equipment to the earthmat/ground pit. Each point of earthing with all formation works like bending, twisting, drilling of holes and connecting by welding (inclusive of all T&P and consumables) to the earthmat/ ground pit/ point of earth connection, all the materials supplied by the contractor Rmtr 50x6-226 50x8-253 75xl2-618 75x6-541 75x8-571 d) Providing 25mm dia M.S.rod 1 .05 Mtr. Long earthmat spikes including heating, bending top 50mm over lap flattening and making spike edge at one end driving into the earth below the ground level and welding the rod with ground mat flat. Each 194 Each 645 Rmtr 513 ii) Same as above but without sodium bentonite clay 30 I u e) Supplying & Providing 450 mm dia 450 mm height 1 .5" to 2" thick hume pipe collar (non pressure type) for earth pits including all lead and lifts etc .. Providine: Deep Bore earthine: I "Sinking bore of 1 50mm clear dia using fast rig including fixing of 40mm dia MS rod, including jointing the pipes as per KPTCL standard and providing sodium bentonite treatment in the annular space, including transportation of rig and other supporting vehicles etc., complete, as per the directions of engineer in charge, including cost of MS rod & sodium bentonite". a) Drilline: 1 50mm dia bore 0 00 0 6 7 33 kV Amount in Rs. Sl No. Description Unit 220 kV 31 32 bl 40 mm dia MS rod c) Bentonite Clav d) Cost of GI flat for joining two rods by welding to obtain continuous lenirth Site surfacine: Rmtr Ke:s 66 kV I 33 kV Per joint 427 a) Spreading and forming stone dust to require level as per specification including cost of all materials,labour,lead etc. complete Cmtr. 260 b) Supplying and spreading lOOmm thick with 20/25mm jelly with all lead and lifts. i) 20/25 mm Jelly Note : Only 20/25mm jelly shall be used. Station Yard Lightning Cmtr. 1 1 12 Per set As per Latest KPWD electrical SR applicable to respective areas. b) Supplying and fixing of Sodium Vapour lamp fittings of 250 watts. Per fitting As per Latest KPWD electrical SR applicable to respective areas. c) Supplying and laying of 1 . lkV, 6 Sqmm PVC cable or any other specified size, testing and commis�ioning of yard lights. Rmtr As per Latest KPWD electrical SR applicable to respective areas. a) Supplying and erection of fabricated supporting structures including foundation. d) Erection of RCC poles with stringing of O.H. conductor/Laying of cable for yard lights. 33 -1 l 1 10 kV 404 11 Rates for different items as per ESCOM SR to be applied. Material + Labour Painting of structures a) Supplying and painting of two coats of good quality Red Oxide primer after cleaning and scrapping the surface. Sqmtr 15+32=42 b) As above with 2 coats of good quality Aluminium paint after2 coats of good quality Red Oxide primer. Sqmtr 35+48=76 c) Supplying and painting two coats of aluminium paint after cleaning and scraping the surface wilthout applying Red Oxide primer Sqmtr 15+26=37 000068 Amount in Rs. SI No. Description Unit 220 kV 34 I I 1 10 kV 66 kV d) As per (b) but with synthetic enamel naint Sqmtr e) Supplying and painting two coats of Synthetic enamel paint after cleaning and scraping the surface without aplying red oxide primer. Sqmtr 22+23=42 Set Set Set 16141 6209 2479 Set Set Set 995 995 995 35+55=81 I 33 kV Battery Set and charger a) Installing, assembling, filling of acid, wiring, assisting, test-charging and discharging Battery set. U 220 Volts iii 1 10 Volts iii) 48/24 Volts b) Erection of Battery Charger and wirina: i) 220 Volts ii) 1 10 Volts iii) 48/24 Volts c) Testing & Commissioning of Battery Charger: Wiring: Identification, Ferruling, Crimping & connecting i) AC Supply cable upto 2 sources ii) Load cables, connection at charger 1 ..,,,,. unto 1 0 ln<>ll nninh• 6509 4261 4261 4261 Testing: i) AC supply voltage phase Sequence. ii) Testing of Output DC Voltages in Boost/ Float/ Trickle/ Variations as per the orderI requirement. iii) Testing for repel factor. Commissioning: i) Fixing of Boost Voltage level ii) Fixing of Float Voltage level iii) Fixing of Trickle Voltage level iv) Testing of alarm, indication and load ckts, Auto/Manual change overs etc. v) Full load test in Boost & Trickle ·-- a) 220 V DC: bl l lOV DC: Per set Per set 26037 17042 17042 17042 . 0000 6 7 Amount in Rs. Sl No. Description Unit 220 kV 35 PLCC Equinments a) Erection of mounting structures for counline: capacitors b) Erection of Coupling capacitors/wave traps/LMU. c) Wiring , testing and commissioning 37 39 33 kV As per Latest KPWD SR applicable to respective areas Set 3886 Set 7771 Set 777 3886 3886 3886 6209 2961 1461 668 668 435 Yard Levelling Yard Levelling and filling up of soil and consolidation. 38 66 kV Fencine: : Colony and Station yard Boundary fencing including erection of supports a) Security fencing using 8G chainlink/ 50mm Mesh b) Barbed wire fencing 36 1 10 kV Watch and Ward Emoluments for watch and ward including pay and DA for 8 hours dutv Transportation Cmt As per Latest KPWD SR applicable to respective areas Per Shift 174 Transportation of Transformer, CT's, A PT's, Breakers, C&R Panels, 1 lkV Switchgears and EHT LA's only. 1 . Usine: 10 MT Lorry Upto 250kms km Rs.30.00 greater than 250kms km Rs.25.00 km km Rs.50.00 Rs.45.00 km km Rs.65.00 Rs.60.00 km km Rs. 100.00 Rs.85.00 2. Usine: 10 MT Truck & Trailor Unto 250kms I greater than 250kms 3. Using 1 1 to 20 MT Truck & Trailor. Upto 250kms greater than 250kms 4. Using 21 MT to 40 MT Truck & Trailor. iU 5 1 to 100 KMs iiil 101 to 150 KMs iv) Bevond 150 KMs Upto 250kms greater than 250kms 5. Using 41 MT to 80 MT Truck & Trailor. , 0 0 0 0 7 .: - Sl No. Description Upto 250kms rereater than 250kms 6. Using 81 MT to 120 MT Truck & Trailor. iiU 101 to 150 KMs iv) Beyond 150 KMs Upto 250kms a:reater than 250kms Note:l)The rates are for up and down journey. 2)Detention charges are Rs. 4500.00 per day for vehicles upto 40MT trailor and Rs.12500.00 for vehicles l arll'!AtPr +h .. ... 40MT ..-..., n-- Amount in Rs. Unit km km 220 kV Rs.450.00 Rs.420.00 km km Rs. 1000.00 Rs.800.00 1 10 kV 66 kV 33 kV 0 0 0 0 7.1 B Sl. N 0 Transportation by Head Load wherever there is no accessability for transportation by vehicle for transmission line works only. Total Distance Steel, Cement, Per Ton in Rs. 3 4 5 6 Beyond 50 Mtrs and upto 100 Mtrs Beyond 100 Mtrs and upto 150 Mtrs Beyond 1 50 Mtrs and upto 200 Mtrs Beyond 200 Mtrs and upto 250 Mtrs Beyond 250 Mtrs and upto 300 Mtrs RCC Pole 300 Kg WL Rate per pole in Rs. included in the item Rate 1 Up to 50 Mtrs initial lead 2 Rough, size, Earth, Gravel, cut Latterite Sand, Lime & Stones, other Str.Mat. Concrete Rate per Cmt in Blocks Rate per Rs. Cmt in RS 14 18 23 283 23 29 36 407 32 40 50 45 1 39 49 61 5 19 49 61 77 5 19 ' 0 0 00 7 � I SI. No. Discription Unit 220 KV I Amount in Rs. 1 10 66 KV KV I I 33 KV d) Using light vehicle including fuel, oil, lubricants and crew subject to a minimum of 100 Kms per day in Per Day Prevailing Board approved Rates case of break down/ subject to prior approval of CEE(Transmission Zone). 40 Loadin2 and Unloading a) Loading of Power Trs, CT's. PT's Breakers, C&R Panels, 1 lKV Switchgears, wavetrap, coupling capacitors, HT UG Cables, Insulators, ACSR Conductor, Ground Conductors, etc., MT 1 3 13 MT 1 3 13 MT 233 MT 233 A) Earth work in surface excavation in the following soil/Rock and removing the excavated types of stuff with all leads and lifts, disposed earth leveled , excavated surface leveled & neatly dressed etc complete as per specifications. a) Ordinary soil b) Hard soil c) Ordinary rock/soft rock/laterite soil d) Hard rock Cmt For sub-station works, rate as per KPWD SR and for Transmission line works, add 25% extra B) i) Construction of revetment/retaining wall with size stone masonry for foundation/basement in CM 1:6 Cmt B ii) Construction of revetment/retaining wall with rubble stone masonry for foundation/basement in CM 1:6 Cmt B iii) Providing and laying pitching on slopes laid over prepared filter media including stone/boulder apron laid dry in front of toe of embankment complete as per drawing and technical specifications Cmt b) Unloading of power Transformers, CT's PT's Breakers, C&R Panels, 1 1 KV Switchgears, Wavetrap, coupling capacitors, HT UG Cables, Insulators, ACSR conductor, Ground conductors, etc., c) Loading of other materials like structural steel, buildinl! materials etc d) Unloading of other materials like structural steel, buildinl!'. materials etc., Benchinl!'., Revetment and Pitchinl!'. .• 41 42 Labour for 66/33KV lines using 9/9.5 Mtrs Long RCC Poles a) Erection of 9 /9.5 Mtrs RCC Poles 300 Kg working load, in the excavated pit as per the approved drawing specification (excluding the cost of excavation, backfilling and concreting) Note: The rates of excavation, Backfilling and concreting are to be adopted as noted in SL nos 3 and 4 resuectivelv. No. For sub-station works, rate as per KPWD SR and for Transmission line works, add 25% extra 497 I 0 0 00 7 3 Sl. No. Discription b) Erection of DP structure excluding cost of erection of RCC poles. Including fixing of braces insulators etc., as per the approved drawings and specifications (excluding the cost of excavation, backfilling and concreting). Note: The rates of excavation, Backfilling and concreting are to be adopted as noted in SL nos 3 and 4 respectively. c) Fixing of V·Shape cross arms, single top supports and insulators. di Fixine: of spiral earth electrodes el Road/P&T Guardine: f) Stringing Rabbit conductor, fixing disc insulator to cross arms etc., ii For hilly terrain iii For plain terrain g) Fixing of guy sets in the excavated pits using 7 /9 or 7/ 10 SWG guy wire / turn buckle, guy rod break insulators, as per the approved drawings and specifications (excluding the cost of excavation, backfillinl? and concretinl?\ Unit Set 220 KV Amount in Rs. 66 1 10 KV KV 33 KV 894 Set 101 62 Set Set 78 668 78 622 KM KM 1803 1290 1 741 1290 Nos. 149 149 RM tr 39 39 Note : The rates of excavation, backfilling and concreting are to be adopted as noted in SL nos 2,3 and 4. 43 h) supplying and fixing of AC devices as per specification Dismantling Same rate as that of erection of Power Transformer i) Dismantling of Power Transformer ii Dismantling charges for conctrete with steel reinforcement Cmt 528 iii) Dismantling of concrete only Cmt 256 iv) Dismantling charges in all other cases 44 Special Locality Allowance Following places are eligible for extra locality allowance ae:ainst each items on labour chare:es a) Dakshina Kannada district Bantwal, Mangalore, Sulya, Puttur, Belthangady taluks. b) UduJ>i : UduJ>i. Kundaour. Karkala Tas c) Uttara Kannada District : Karwar, Supa, Haliyal, Sirsi, Mundagodu, Yellapur, Bhatkal, Siddapur, Honnavar. Kumta Ankola Ta s. d) Kodagu District : Madikeri, Virajpet, Somarwarpet, Tas. e) Chikkamagalur District : Kadur, Chikkamagalur, Koppal, Tarikere, Mudigere, Narasimharajapura, Srine:eri Tqs. I fl Shimoe:a District : i) Hosangar, Thirthahally, Sagar, Sorab, Shikarpur Tqs ii) Shimoe:a. Bhadravathi, Honnali Tqs I 2) Davane:ere District : Chennae:iri Ta only 75% of erection charges in general 35% 35% 35% 35% 25% 25% . 15 % 15% 0 0 0 0 7 �. SI. No. Discription hi Dharwad District ii Kal2ata2i ii) Dharwad Ta i) Haveri District : ii Hangal, Herekerur iii Byda2'.i, Shi2aon, Savanur Tas., Iii Bel2aum District ii Khanauura Ta Unit 220 KV I Amount in Rs. 1 10 66 KV KV I 25% 15% 25% 15% 25% ii) Hukkeri, Belgaum, Bylahongal, Soundatti Taluk's only. 15% k) Mysore District : Heggadadevanakote, Hunsur Tqs 25% 1) Chamarajanagar District : Gundlupet, Chamaraiana2'.ar. Kolle2al Tas m) Hassan District : Sakaleshpur, Hassan, Arakalagud, Belur. Alur, Taluks onlv. Note: 1) In case of civil works where KPWD SR rates are adopted, the locality allowance as applicable in KPWD SR shall be followed. 2) J'or all other works the locality allowance as indicated above shall be followed. I 33 KV 25% 25% . 000 0 7 5 Amount in Rs. Sl No. Description Unit 220 kV 45 Surveying of cable route excavation trial holes as per field requirements, preparation of cable route profile, drawings 1 for cable laying, final route alignment, marking lines and grades, preparation of final cable route, drawings after laying and energising for preparing bill of materials. kms. 68,807.70 1 10 kV 38,855.70 cable below footpath in the following strata of soil by mechanical/ manual means including removing and re-rixing the kerb and pavement stone slabs, removing and re-rixing masonry of other services with patch work, deposition of earth/rock on bank with all leads and lifts including shoring, strutting, providing caution boards, danger lighting, Bracing, sheeting , bailing out of water, barricades and other works not specifically mentioned herein but required for the completion of work in all respects - a) Ordinary soil/ Black Cotton Soil I--� 2 b) Hard soil cl Hard Laterite Soil/Dry fissured rock. d) In hard rock with chiseling and wedging Cmt. 232.50 Cmt. Cmt. 298.2 2 720.10 Cmt. 988.28 Cmt. Cmt. Cmt. Cmt. 132.50 198.22 620.10 888.2 8 - B) Earth work excavation for laying of UG cable in open ground and beneath the road surface in the following strata of soil by mechanical/ manual means deposition of earth/rock on bank with all leads and lifts including shoring, strutting, providing caution boards, danger lighting, Bracing, sheeting, bailing out of water, barricades and other works not specifically mentioned herein but required for the completion of work in all respects. I--i--i--- a) Ordinarv soil/ Black Cotton Soil bl Hard soil cl Hard Laterite Soil/Dry fissured rock. d) Hard rock with chiseline: and wede:ine: 38,855.70 Note:-1.Extra for excavation under water condition and or foul conditions including bailing/ pumping out removal of slush add 20% of the rate. 2. In the case of excavation for pits or trenches of width more than 600mm and less than 1500mm add 25% extra and for width upto 600mm add 50% extra. 3.The indicated rates are applicable for works in BBMP limits of Bangalore.For other areas the rates of respective KPWD Circles shall be considered. 4.No extra area weightage need to be added to the rates inidcated here since the PWD area weightage is already considered A) Earth work excavation for laying of UG I--- 66 kV Amount in Rs. Sl No. Description Unit 220 1 10 66 kV kV kV Note:1.The indicated rates are applicable for works in BBMP limits of Bangalore.For other areas the rates of respective KPWD Circles shall be considered. 2 No extra area weightage need to be added to the rates indicated here since the PWD area weightage is already considered Cutting the road surface for laying of cable & disposing of the excavation I debris with all leads and lifts to any notified disposal 3 point of the local bodies/as directed including providing barticading, danger lighting/ caution boards etc., in the following classifications of road surfaces a) Macadam road surface Cmt. 293.62 bl Asohalt surface Cmt. 4 17.64 c) Cement concrete surface Cmt. 665.68 Laying EHT single core, XLPE copper cable in trefoil, tapping, fixing pipes for drain and gate crossing as per drawings & specifications in trench pipes, ducts by pulling, drawing etc., including transport, handling of cable drums, paving out cables 4 using standard cable installation il:ms-ckt 1,900,402.53 equipments. NOTE: The quoted rate per km shall include laying one circuit per km each circuits consisting of 3 Nos. Single core cables including transport of cable drums material, equipments to site and retaining unused items to stores. • 5 Supplying and filling sieved/riddled sand of approved quality in cable trenches Cmt. including all lead, lift, watering, ramming, etc complete Design, Engineering, supplying RCC protection covers with M20 Grade concrete and Fe 4 1 5 steel, handling and covering the cables in the trench as per the drawing, 6 specifications and directions of the Engineer in charge of the work Back filling the cable trench with selected available ridded earth from the trench excavation & consolidating with ramming 7 in successive layers of 15 Cms thickness, watering wherever necessary, achieving 96 % proctors density, forming a crown for � . . . 728,9 10.00 62 1 ,69 1.20 1,274.00 Rate is same for all capacity of cables.Refer notes as in item 3. Smtr 106 1.00 Rate is same for all capacity of cables.The rate is same for all circles and areas.No extra weightage to be added. Cmt. 53.00 Rate is same for all capacity of cables.Refer notes as in item 3. · -... -- 0 00 01 1 Amount in Rs. SI No. Description Unit 220 kV 8 Disposal of surplus earth/rock to the areas directed/notified areas of disposal point of the local bodies including all lead and lift charges loading, unloading etc complete 66 kV 1 10 kV Rate is same for all capacity of cables.Refer notes as in item 3 . Cmt. 174.48 Handling and making normal straight 9 joints for EHV power cables with all consumables at site etc., complete. Nos. 294,890.3 1 64,350.00 3 1 ,084.56 Handling and making of cables end 10 termination for EHV single core XLPE copper cable. Nos. 308,943. 18 64,350.00 3 1,084.56 Erection of cross bonding single phase earth link boxes on to the cable mounting 1 1 structure connecting earth leads with all lugs, f"ixtures, clamps bolts, and nuts complete. Nos. 28,084.68 23,3 13.42 23,3 13.42 Supplying, handling and fixing RCC cable route markers and joint markers as per the 1 2 specifications, approved drawing and directions of the Engineer in charge of the work. Design engineering, supply of all labour, material and construction of RCC (M20 Grade) footings and pedestals of any section/size including the cost of excavation in all types of soil/rock, back filling with available approved earth/new earth, disposal of surplus earth/rock to the places directed, concrete (M20 Grade and lean concrete 1 :4:8), reinforcement steel, 1 3 form work, grouting, under pinning, foundations strengthening in expansive/BC soil, curing, sundries and other items not mentioned herein but required for the completion of work as per technical specifications, approved drawing and directions of engineer in charge of the work. For EHV cable termination structure Nos. 230.00 Nos. 25,766.00 Rate is same for all capacity of cables.The rate is same for all circles and areas.No extra wei1Zhta11:e to be added. 7, 142.00 7, 142.00 00001 0 Amount in Rs. SI No. Description Unit Design, Engineering and construction of RCC Cable Joint Bays to accommodate jointing of 3 Nos (Single Circuit)/ 6 Nos (D,ouble Circuit) as required of single core XLPE UG Cable as per specifications, drawings and directions of the Engineer in 14 charge of the work. The bidders shall inspect the site and quote duly furnishing designs and drawings. The joint bays shall be filled with riddled sand after completion of all the other works viz., construction of joint bay, laying of cable, testing etc. a) for 220KV Cables 9.00xl.60xl.60 m clear b) for 66KV Cables, 4.00xl.80xl.50m clear size size of of bay bay Surface Restoration Providing road restoration work consisting of Granular Sub-Base, wet mix macadam, bituminous macadam, bituminous concrete, Primer Coat & Tack Coat as per BBMP 1 5 specifications /requirements and drawing including cost of all materials, labour, over heads, machineries etc., and directions of the Engineer in charge of the work. (Note: For detailed specifications KPWD SR of Bangalore Circle and NH SR shall be referred.) Cable trench clear width Cable trench clear width 1.00mtr 220 kV 1 10 kV 66 kV The rate is same for all circles and areas.No extra weightage to be added. Nos. 346,997.00 Nos. 176,323.00 Rmtr. Rmtr. 1398.35 Rmtr. 1747.94 Rmtr. 262 1.9 1 1 .50mtr 00001 1 Amount in Rs. SI No. Description Unit 220 kV Cable Crossing Arrangements: Design, Engineering and construction of Cable crossing arrangements at Rail, Bridges & Culverts/ Storm water drains/Water Supply Line, etc. The arrangement shall accommodate 3 Nos (Single Circuit)/ 6 Nos (Double Circuit) as required of single core XLPE Cable. Construction of crossing arrangements shall include RCC cable ducts, RCC/Stone Masonry piers, abutments, Wing walls, 16 Returns, Wall foundations, etc. The bidders shall inspect the site and quote duly furnishing designs and drawings. The successful bidders shall furnish the designs and drawings in accordance with the requirements of the statutory authorities (National & State High ways, BBMP, Railways, BWSSB, BSNL, KPTCL/BESCOM etc.) and execute the work as per the approved drawing and directions of the Engineer in charge of the work. Cement concrete 1 :2:4: Providing and laying site mix/Ready mixed cement concrete of 1:2:4 proportion for embedding the HDPE pipes in road crossings and for other works using 20mm and down size granite jelly and clean sieved sand laid in 15cm thick layers and well compacted including vibrating, curing etc with all lead and lift, smooth finishing for exposed faces and with necessary centering and form work etc complete. 1 10 kV 66 kV Rmtr. The rates to be arrived based on the drawing and site requirement.The estimates shall be prepared in consultation with civil engineers of the circle Cmtr 4,327.98 Horizontal trench less cutting: Design of cable crossing arrangement at highway using HDD arrangement shall �kt-mtr 19 accommodate crossing of XPLE UG cable .The work shall be carried out as per the directions of KPTCL in charge of the work. 17,550.00 1 1 ,700.00 1 1,700.00 Laying of 12 Fibre Dual Window Mono 20 Mode (DWMM) Optical Fibre Cablea as per drawinizs & soecifications. kms. 6,000.00 6,000.00 6,000.00 Handling and making straight through 21 joints closures for 12 Fibre Dual Window Mono Mode (DWMM) Optical Fibre Cable Nos. 14,063.86 14,063.86 14,063.86 ooooau Amount in Rs. SI No. Description Unit 220 kV 1 10 kV 66 kV Handling and making terminal joints for 1 2 22 Fibre Dual Window Mono Mode (DWMM) Nos. 16,850.34 1 6,850.34 16,850.34 Optical Fibre Cable Supplying and providing PVC warning Tapes 150mm wide & 100 Microns thick as 23 Rmtr per specifications, drawings and directions of the Engineer in charge of the work. ----- HDPE Pipes: Supplying & providing HDPE pipe 6 mm thickness (as per IS 4984) with 24 necessary accessories for road crossing, drive ways etc 1 60mm dia a) b) 230mm dia Rmtr Rmtr 45.00 2,050.00 ooooa 1 PART III: SCHEDULE O F RATES FOR REPAIR OF POWER TRANSFORMER Sl. No. DESCRIPTION OF WORKS UNIT 1 Draining out oil from the Power Transformer complete collecting the oil in barrels (supplied by KPTCL) shifting barrels t o safe place (in the station premises only) with proper tightness of cork/lid to avoid entry of moisture. Ltrs. 1.17 2 Unloading of the Faulty Transformer tank with active parts of accessories at firm's work or loading of repaired Transformer tank with active parts o r accessories at firm's works MT 171 3 Dismantling faulty transformer for joint inspection at repairers premises including all activities such as opening of top cover, de-tanking of core and winding, separation of HV/LV coils, conducting of preliminary test required for assessment of repair work to be undertaken, dismantling core etc., in the presence of KPTCL authorised representative. Amount in Rs. 5 MVA 6.3 MVA S MVA lO MVA 12.5 MVA 16/20 MVA 17097 17097 25645 40410 4274 1 5 1290 3 1 .5MVA 5 1290 4 5 MVA 6.3 MVA Providing new windings in place of damaged winding S MVA including cost of materials, labour, drying etc., (Both HV lO MVA & LV) - per Kg of winding 12.5 MVA 16/20 MVA 3 1.5MVA 933 933 933 933 933 933 933 5 Providing solid insulation materials for replacement to damaged or burnt insulation as per actual weight. Kgs. 466 Providing re-insulation to HV/ LV winding whenever necessary for total weight of winding except solid insulation Kgs. 171 Providing new CRGO lamination to the core in place of damaged lamination wherever necessary including cost of materials and labour. Kgs. 435 Repair and overhauling of OLTC each Divertor switch including change of oil, lubrication and replacement of gaskets and other parts which are locally available 5 MVA 6.3 MVA S MVA lO MVA 12.5 MVA 16/20 MVA 3 1.5MVA Spares for OLTC/Divertor switch (spares to be procured . from the o rie:inal manufacturers onlv) LS 6 7 17097 17097 25645 25645 34193 34 193 34 193 As per Actuals o o o o ai 1 SI. No. DESCRIPTION OF WORKS 8 Cleaning, Repairing and painting inside the Transformer Tank with hot oil bath and acid proof epoxy paint and painting outside the tank with enamel paint after thorough cleaning including the cost of materials including the painting of radiators at site/Firm. 9 Re-assembly of Core and winding Drying out the assembly of core and winding in oven/ vacuum chamber, till the specified insulation resistance 10 values are obtained (including cost o f materials and labour) Tanking the assembly, giving connection, providing new gaskets and insulating materials conforming to relevant ISS, putting back the cover, tightening the fixtures, 1 1 fixing the bushing etc., including the cost of all materials like Gasket, insulating materials, Bolts and Nuts etc., and labour. Other accessories at repairers work to facilitate the testing. Filling of oil to the main tank and OLTC tank, filtering the oil including filtering till attainment of prescribed BDV valves including labour, filtering equipment along 12 with accessories. The minimum BDA value shall be 50KV. Note: The Transformer oil will be supplied by KPTCL. Spares for Transformer such as Bushing, Oil gauge, 13 valves etc., which shall be procured from the orginal manufacturers. 14 Other snares a) Testing the transformer for routine tests as per IS 2026-1983 if repairs are carried out at Repairer's work. b) Testing the transformer for IR values, Voltage ratio at 1 5 all Taps, Short circuit test, Magnetic balance, Magnetising current measurement at low voltage from HV & LV. Magnetising current measurement at rated voltage from LV side. UNIT 5 MVA 6.3 MVA 8 MVA lO MVA 12.5 MVA 16/20 MVA 3 1 .5MVA 5 MVA 6.3 MVA 8 MVA l O MVA 12.5 MVA 16/20 MVA 3 1 .5MVA 5 MVA 6.3 MVA S MVA lO MVA 12.5 MVA 16/20 MVA Amount in Rs. 1865 1 1865 1 22536 34 193 34 193 37301 37301 17097 17097 25645 48 1 8 1 54398 59838 59838 2 1 760 2 1760 32638 606 1 5 69940 76 158 3 1.5MVA 5 MVA 6.3 MVA S MVA lO MVA 12.5 MVA 16/20 MVA 76 158 12822 25645 25645 25645 34193 34 193 3 1.5MVA 34 193 5 Ltrs. LS Actuals LS Actuals S MVA 17097 6.3 MVA S MVA 25645 34193 l O MVA 34 193 12.5 MVA 34 193 16/20 MVA 34 193 -.. 000033 2 Sl. No. DESCRIPTION OF WORKS 16 Providiniz: new Transformer Oil 17 Transit risk insurance 18 Supervising and commissioning of Transformer in the presence of RT Staff as and when the Transformer is ready for commissioning ' 19 I Scrap value of Copper.Iron and CRGO sheets a) Scrao Cooper b) Scrap Iron cl Scrap CRGO UNIT 3 1 .5 MVA Ltre. LS Amount in Rs. 34 193 89.00 As per actuals S MVA 6.3 MVA S MVA lO MVA 12.5 MVA 16/20 MVA 3 1 .5MVA 8548 8548 8548 13988 13988 13988 1 3988 Rate / ke: Rate/ kg Rate / ke: 3 1 5.9 1 9.89 52.65 3