KARNATAKA POWER TRANSMISSION CORPORATION LIMITED
Corporate Office,
Kaveri Bhavan,
Bangalore - 560 009.
No.
B19/7625/86-87
Encl:
Dated:
� 1 APR 2013
To,
All The ChiefEngineers (Electricity),
Transmission Zones, KPTCL, Bangalore/Mysore/Tumkur/Hassan/Bagalkot/Gulbarga,
The ChiefEngineers (Electricity), P&C, T&P, TA&QC, RT and R&D, KPTCL.
Sir,
Sub:- Revision of Major Works Schedule of Rates as per the recommendations of
S.R. Revision Committee and as per the approval of Central Purchase
Committee - reg.
Ref:- 1. KPTCL Order of even No. Dt. 18.02.2012- Constitution of Committee
for revision of Major Works Schedule of Rates.
2. Discussions held on 21 &22.03.2013 in the 131 st T&P Central Purchase
Committee meeting.
The Major Works Schedule of Rates has been revised with effect from 01.04.2013. As
such, the revised S.R will be in force from 01.04.2013 till further orders. The copy of the
revised SR is notified in the KPTCL website for information and use of all the officers of
KPTCL for its effective implementation with immediate effect. The estimates I DPRs
prepared from 01.04.2013 shall be based on the revised S.R without fail. You are hereby
directed to instruct all your sub-ordinate offices I officials in the matter. The booklets of
the Major Works S.R shall be made avail�ble to all offices in due course.
Yours faithfully
9,,9.l 11�ot.o4.,f�
Deputy General Manager (Tech.),
Copy to:
KPTCL, Bangalore.
The Financial Adviser (A&R) I (I/A), KPTCL, Bangalore
All Superintending Engineers Works I Works &Maintenance Circles, KPTCL
All Controller of Accounts, Transmission Zones, KPTCL.
All Executive Engineers, Electy., Major Works/TL&SS Divisions, KPTCL
Copy for information to:
PS to Managing Director
I Director (Transmission) I Director (Finance) I Director(RA)&
Secretary, KPTCL to bring to the notice of the Directors for information.
�
T�uperintending Engineers (Elec.,) IT&MIS with a request to upload the revised S.R on the
'�PTCL website.
.
KPTCL MAJOR WORKS SCHEDULE
OF RATES
WITH EFFECT FROM 01.04.2013
INDEX
SI.
No.
Description
Page Nos.
1
Part-1 : Material Portion
01-44
2
Part-2 : Labour Portion
45-81
3
Part-3 : Transformer Repairs
82-84
PART-I
RATES FOR MAJOR WORKS MATERIALS/EQUIPMENTS
SI.
No.
1
Description of Materials
Unit
Amount in
Lakhs.
A POWER TRANSFORMERS:
1
2
3
150 MVA, 3 Ph 220/66/ l lkV , Oil forced cooling,
complete with all fitting and accessories,OLTC, RTCC,
FCC, first filling of oil and 10% spare oil in non-returnable
drums.
lOOMVA, 220/66 / 1 1 kV Transformer complete with
accessories as in item No. 1 above
lOOMVA, 220/ 1 10/ 1 1 kV Auto transformer complete with
accessories as in item No. 1 above
No.
648.01
No.
529.97
No.
343.55
4
31.5 MVA, 66/ 1 1 kV Transformer complete with
accessories as in item No. 1 above
No.
172.03
5
16/20 MVA, 66/ 1 1 kV Transformers complete with all
fittings and accessories, OLTC, RTCC first filling of oil
and 10% snare Oil
No.
136.30
6
20 MVA, 1 10/33/ 1 lkV Transformer with accessories as in
item No. 5.
No.
134.80
7
12.5 MVA, 66/ l lkV Transformer with accessories as in
item No. 5.
No.
1 1 1.23
8
10 MVA 1 10/33/ l lkV Transformer with accessories as in
item No.5
No.
95.79
9
8 MVA 66/ 1 1 kV Transformer with accessories as in item
No. 5
No.
73.31
10
EHV Grade Transformer oil in new steel barrels of
2 101itres capacity strictly confirming to IS 335/ 1993
kL
0.89
B I) EHV CIRCUIT BREAKERS:
1
220 kV
No.
14.47
2
l lO kV
No.
6.16
3
66 kV
No.
5.38
4
33 kV
No.
2.69
Incomer Panel
No.
4.65
Feeder Panel
No.
3.66
Feeder Panel for capacitor bank
No.
4.02
,
II) 11 kV SWITCH GEAR
A
1 lKV PCVCB, 350MVA, 20KA, 1250A incomer 800A feeder
Rs
SI.
No.
B
c
D
Description of Materials
Unit
Amount in Rs
Lakhs.
l lKV MCVCB, 3SOMVA, 20KA, 12SOA incomer SOOA
feeder
Incomer Panel
No.
S.S9
Feeder Panel
No.
S. lS
Bus Coupler
No.
S.02
Feeder Panel for capacitor bank
No.
S.4S
Incomer Panel
No.
6.00
Feeder Panel
No.
S.24
Bus Coupler
No.
S. lS
Feeder Panel for capacitor bank
No.
s.ss
Incomer Panel
No.
7.62
Feeder Panel
No.
6.19
Bus Coupler
No.
6.77
Capacitor panel
No.
6.S4
Adapter Panel ( 12SOA)
No.
1.1
Adapter Panel (2000A)
No.
1.2S
11/c + 4F
No.
O.S6
11/c + SF
No.
1.11
21/c + SF
No.
1.SS
11/c + 4F + lCB
No.
1.02
11/c + SF + lCB
No.
1.26
21/c + SF + 2CB
No.
1.S6
21/c + SF + lBC
No.
1.69
l lKV MCVCB, SOOMVA, 2SKA, 1600A incomer 12SOA
feeder
l lKV MCVCB, SOOMVA, 3 1 .SKA, 2000A incomer 1600A
feeder
E Adapter Panel for MCVCB
F
Annunciator Panel for the following combinations (Both
for MCVCB & PCVCB)
000002
1i
-·
Sl.
No.
c
Description of Materials
Unit
Amount in
2I/c + lOF + lBC
No.
1.86
2I/c + 12F + lBC
No.
2.03
2I/c + 14F + lBC
No.
2.2
2I/c + 16F + lBC
No.
2.52
CURRENT TRANSFORMERS with 0.2 accuracy class:
1
220 kV Class
Nos.
3.23
2
1 10 kV Class - 600-400 / l- 1 - lA (for lOOMVA Tr.)
Nos.
1.41
3
l lOkV Class 400-200/ 1-l-lA
Nos.
1.14
4
1 10 kV Class - 200- 100/ l-l-lA
Nos.
1. 14
5
66kV Class 1600-1000/ 1-1-lA
Nos.
1.19
6
66 kV Class - 1000-800-600/ l-l-lA
Nos.
1.19
7 66 kV Class - 400-200/ 1- l-lA
Nos.
0.78
8
66 kV Class - 200-100/ 1-1- lA
Nos.
0.78
9
33 kV Class 400-200/ l-l-lA
Nos.
0.23
10 33kV Class 200- 100/ l-1-lA
Nos.
0.23
1 1 1 1 kV NCTs 2000- 1200/ 1-1- lA(for 31.5kA SWG)
Nos.
0.26
12 l lkV NCTs 1200-800/ 1-1-lA ( for 500MVA SWG)
Nos.
0.23
13 l lkV NCTs 800-400/ 1-1-lA (for 350MVA SWG )
Nos.
0.23
Nos.
0.23
Nos.
0.26
Nos.
0.23
Nos.
0.23
Nos.
0.23
Nos.
0.23
Nos.
0.23
14
Rs
Lakhs.
l lkV NCTs 600-300/ l-1-lA ( for PCVCBs upto lOMVA
transformer)
15 1 lkV CTs of ratios
1 1 kV CTs 2000- 1200/ 1-1- lA(for Incommer/Bus coupler
for 3 1 .5kA SWG)
l lkV CTs 1200-800/ l - l- lA ( for Incomer/Bus coupler for
ii
500MVA SWGl
l lkV CTs 800-400/ 1-1-lA (for Incomer/Bus coupler for
iii
350MVA SWG )
l lkV CTs 600-400/ 1-1-lA ( for for feeders of 3 1.5 kA
iv
SWG)
l lkV CTs 400-200/ 1-1-lA ( for for feeders of 500MVA
v
SWG)
i
vi l lkV CTs 200- 100/ 1-l-lA ( for feeders of 350MVA SWG)
D CAPACITOR VOLTAGE TRANSFORMERS:
000003
SI.
Amount in
Description of Materials
Unit
1
245kV CVT, 8800 PF, one phase CVT with 3 secondaries.
Nos.
3.28
2
245kV CVT, 4400 PF, one phase CVT with 3 secondaries.
Nos.
2.88
No.
Lakhs.
E VOLTAGE TRANSFORMERS:
1
22okv1v31 1 1ov..J3 / 1 1ov v3 - 1 1ov / ..J3
Nos.
2.48
2
3
l lOkV / v3/ 1 10V/ v3 - 1 10V/ v3-1 10Vv3
66kV/ v3 / uov/ v3- 1 1ov/ v3 -uov/'13
Nos.
Nos.
1.19
0.78
4
33kV/ v3 I 1 lOV / v3-l 10V / v3
Nos.
0.28
Nos.
0.24
5 l lkV / l lOV-l lOV (THREE PHASE)
F LIGHTNING ARRESTORS (POLYMERIC):
1
198 kV Metal Oxide type, with surge counter (Discharge
Class - 3)
Nos.
0.43
2
96 kV Heavy Duty Metal oxide (Discharge Class - 2 for
lines & Transformers)
Nos.
0.34
3
60 kV 10 KA Normal Duty (Discharge Class -2 )
Nos.
0.15
4
30 kV Normal Duty Metal oxide (Discharge class -2 )
Nos.
0.087
5
96 kV Heavy Duty Metal Oxide (Discharge Class -3 for
Capacitor bank )
Nos.
0.34
6
60 kV Normal Duty Metal Oxide (Discharge Class -3 )
Nos.
0.15
Nos.
0.07
7 30 kV Normal Duty Metal Oxide (Discharge Class -3 )
G ISOLATORS:
1
220 kV, 1250 A, 3 1.5 KA/40 KA for three seconds short
time current rating remote, electrically cum manually
operated double break type Disconnects with Solid core
insulators:
a
Uurie:ht with Earth Switch LPH 5750 mm.
Set
2.71
b
Upright without Earth Switch (live point height 5750 mm)
Set
2.34
c
Upright without Earth Switch (live point height 8250 mm)
Set
2.44
d
Underhung without Earth Switch ( 12850 mm Mounting
heie:ht)
Set
2.65
2
l lOkV, 1250 A, 3 1.5 KA double break Electrically cum
manually operated isolators as detailed in item No. 1:
a
Upright with Earth Switch LPH 4600 mm.
Set
1.92
b
Upright without Earth Switch( live point height 4600mm)
Set
1.77
�-a."age,(;;
��
�
�· �
i
,.,...
c::
l���J
?l
�
.
�
eiY
'O�K�":'·
......
,,.
..
ooooo.4
Rs
Sl.
Description of Materials
No.
c Upright without Earth Switch( live point height 6350mm)
Unit
Amount in Rs
Lakhs
Set
1.77
Set
1.96
a Upright with Earth Switch LPH 4600 mm.
Set
1.87
b Upright without Earth Switch( live point height 4600mm)
Set
1.72
c
Upright without Earth Switch( live point height 6350mm)
Set
1.72
d
Underhung without Earth Switch (10000 mm Mounting
heie:ht)
Set
1.91
4
66 kV, 1250A/800A, 3 1.5KA double break Electrically
cum Manually operated isolators as detailed in item 1 :
a Upright with Earth Switch LPH 4250 mm.
Set
1.51
b Upright without Earth Switch (live point height 4250mm)
Set
1.2
c Upright without Earth Switch (live point height 5500mm)
Set
1.14
d Underhung without Earth Switch
66 kV, 1250A/800A, 3 1.5KA double break Manually
5
operated isolators as detailed in item 1:
a Uprie:ht with Earth Switch LPH 4250 mm.
Set
1.24
Set
1.46
Upright without Earth Switch (live point height 4250mm)
Set
1 . 15
c Upright without Earth Switch (live point height 5500mm)
Set
1.09
d Underhune: without Earth Switch
66 kV, 2000A, 3 1.5KA double break Electrically cum
6
Manuallv operated as detailed in item 1:
Set
1. 19
Set
1.47
b Upright without Earth Switch 4250mm
Set
1.50
c Upright without Earth Switch 5500mm
Set
1.54
d Underhung without Earth Switch
Set
1.47
Set
0.58
Set
0.49
Set
0.57
Underhung without Earth Switch ( 10000 mm Mounting
heil(ht)
l lOkV, 1250 A, 3 1.5 KA double break Manually operated
isloators as detailed in item No. 1 :
d
3
b
Upright with Earth Switch
a
33kV Isolators with electrically cum motor operating
mechanism
7
33 kV, 800 A, 25 KA Upright with Earth Switch complete
metallic portion with insulator
33 kV, 800 A, 25 KA Upright without Earth Switch (live
b
I point heil(ht 3750mm)
33 kV, 800 A, 25 KA Upright without Earth Switch (live
c
'Point heie:ht 4750mm)
a
�
�<onage,
(;>;
�
.
6lc
=?:
� �-=
�
I(!)
�f o�
'•
�
Ob
�
c,'v
000005
SI.
No.
Description of Materials
33 kV, Isolators:
33 kV, 800 A, 25 KA Upright with Earth Switch complete
a
metallic portion with insulator
33 kV, 800 A, 25 KA Upright without Earth Switch (live
b
'Point heil!:ht 3750mm)
33 kV, 800 A, 25 KA Upright without Earth Switch (live
c
'Point heil!:ht 4750mm)
H BATTERY SETS :
l)Tubular tv'Pe:
i 48 V. 200 AH
ii
Unit
Amount in
Lakhs
8
Set
0.53
Set
0.44
Set
0.60
Set
0.73
Set
1.45
l lOV, lOOAH
Set
2.50
ii 220V, 300AH
Set
15.44
I
i
1 10 V, 100 AH (with float cum boost battery charger
working on 230 V 1 Ph AC supply as per specifications).
Set
0.96
Set
0.93
2 x 220V, 300 AH (with mains and standby float and boost
iii battery charger working on 415V 3 Ph AC supply as per
specifications).
Set
4.66
Nos.
0.33
AC distribution Box Double front (outdoor type) 24
ii Terminal 1200x1350x600mm, two l/C of lOOAmps MCCB
20kA + 24 O/G MCB 16 Amps + 2 O/G of lOOA, HRC fuse
Nos.
0.76
LTAC panel(indoor), 4 1 5V as per technical specification
compraising of voltmeter and ammeter, 2 l/C ACB 800A+2
iii O/G SFU, 200A + 8 O/G SFU 100A+l40/G SFU, 63A+l2
O/G, 32A+lB/C SFU, 800A+lDG Change over switch 300A
etc.
Nos.
6.96
DC distribution panel (Indoor) 11/C SFU-200 A + 10 O/G
iv SFU 63A+l0 O/G SFU 32A with relays for DC failure & DC
Bus earth fault as per Techincal Specification
Nos.
1.11
Nos.
0.45
l lO V, lOO AH
II) Plante Tv'Pe:
i
ii
J
I
i
BATTERY CHARGER:
48 V, 200 AH
LTAC Panels and ACDBs
For 400 kV and 220 kV stations:
AC distribution Box Single front (outdoor type) 6 Terminal
1200x1350x300mm, one l/C of lOOAmps MCCB 20kA + 6
O/G MCB 16 Amps + 1 O/G of lOOA, HRC fuse
II For l lOkV and 66kV stations:
i
AC distribution Box Single front (outdoor type) 6 Terminal
1200x1350x300mm, one l/C of lOOAmps MCCB 20kA + 6
O/G MCB 16 Amps + 1 O/G of lOOA, HRC fuse
��:a:nager(;;
�
'9�
g
:]?..
j �h�
<!>
�
?"l'
o'•
o._..
�
�
�'lo £
-::::::
· i•
'V,
c"":to
o��
--
OOOOOb
Rs
Sl.
Description of Materials
No.
Unit
Amount in
Lakhs.
LTAC panel(indoor), 415V as per technical specification
compraising of voltmeter and ammeter, 11/C MCCB
ii 200A+2 Nos. 3-Phase 63A O/G SFU, + 2 Nos. 3-Phase 32A
O/G SFU 100A+140/G SFU, 6 Nos. 3-Phase 16A SFU etc.
comnlete
Nos.
1.13
DC distribution panel (Indoor) as per technical
specification comprising of earth fault indicator,iri.dication
iii
circuit for AC mains failure, 1 No lOOA SFU for I/C+12 Nos
32A SFU for 0/G
Nos.
0.75
CAPACITOR BANK with 0.2 % Series reactor & NCT:
DesignEngineering supply erection testing &
commissioning of Capacitor Banks with internal fuses,
terminal connector suitable capacity Neutral CTs, & 0.2%
K
series reactors on neutral side with elevating/ mounting
structure and with 10% spare capacitors complete. (This
does not include breaker, panel, civil works like
excavation and foundation concreting works)
i
123kV 24 MVAR (Double star, double Bank of 4x6 MVAR)
Set
25.76
ii
123 kV, 20 MVAR (Double star, double bank of 4x5 MVAR)
Set
2 1.46
Set
2 1.01
Set
20.79
Set
25. 12
vi 12. lkV 2.9 MVAR star connected Capacitor bank
Set
3.43
vii 12. lkV 5.8 MVAR star connected Capacitor bank
Set
6. 13
viii 12. lkV 2.5MVAR star connected Capacitor bank
Set
3.83
Km
0.66
ii 2 Core 6 sq.mm
Km
1.17
iii 4 Core 2.5 sq.mm
Km
0.99
iv 4 Core 6 sq.mm
Km
1.97
10 Core 2.5 sq.mm
Km
2. 18
vi 14 Core 2.5 sq.mm
Km
2.91
vii 19 Core 2.5 sq.mm
Km
3.82
viii 4 Core 4 sq.mm
Km
1.39
Km
1.03
123kV 24 MVAR (Double star connected Bank of 2x12
MVAR)
72.5kV 20MVAR (Double star connected Bank of
iv
4x5MVARl
72.5kV 20 MVAR (Double star connected Bank of 2xl0
v
MVARl
iii
Copper Control Cables:
L
2 Core 2.5 sq.mm
i
v
ix 2 Core 10 sq.mm
�;,�a\Ma�
�
0qj
�
�
I��
!!>£.
'�
\•
Cl
�, *.f..... ·l-?T.cl..
..
.::,
g·
\'S
*
·-
.ooooor
Rs
SI.
No.
Description of Materials
Unit
Amount in Rs
Lakhs.
4 Core 10 sq.mm
Km
3.06
xi 4 Core 16 sq.mm
Km
4.47
xii 4 Core 25 sq.mm
Km
3.57
xiii 2 Core 150 sq.mm
Km
20.38
x
M
1. lkV class Armoured Aluminium Cables:
a
4x240 sqmm Aluminium,cable with glands/lugs/ferrules
Km
7.92
b
4x95 sqmm Aluminium,cable with glands/lugs/ferrules
Km
3.34
c
4x70 sqmm Aluminium,cable with glands/lugs/ferrules
Km
3.34
d
4x25 sqmm Aluminium,cable with glands/lugs/ferrules
Km
1.08
No
5.19
ii 66kV line panel
No
5.06
iii 1 10/33kV Tr. panel
No
6.5
iv 1 10/ l lkV Tr. panel
No
6.5
No
5.23
vi 33kV line panel
No
2.43
vii 1 lkV capacitor Bank panel
No
3.9 1
C&R Panels compatible to SCADA for installation in 220kV
sub stations:
i 220 kV line panel - Type 2L
ii 220/66/ 1 1 kV Transformer panel- Tvpe 2T6
Nos.
Nos.
10.73
20.07
iii 220/ 1 10/ 1 1 kV Transformer panel - Type 2Tl
Nos.
20.22
iv 220 kV Bus Coupler panel - Type 2BC
Nos.
5.55
Nos.
24.5
vi 1 10 kV line panel - Type lL
Nos.
8.37
vii 1 10 kV Bus Coupler panel - Type lBC
Nos.
4.97
viii 1 10/ 1 1 kV Transformer panel - Type lTl
Nos.
16.01
Nos.
10. 14
66 kV Bus Coupler panel - Type 6BC
Nos.
4.97
xi 66/ 1 1 kV Transformer panel - Type 6Tl
Nos.
15.80
C&R Panels compatible to IEC6 1850, communication
c protocol for station automation system in 220kV sub
stations:
i 220 kV line Type 2Llas per annexure RPPI-SAS)
Nos.
10.73
CONTROL AND RELAY PANELS:
1 10kV/66kV/33kV Stn.- Simplex l lOV DC compatible to
A
SCADA
2 A
i
v
l lOkV line panel
66/ l l kV Tr. panel
B
v
220 kV Bus Bar Protection panel - Type 2BBA
ix 66 kV line panel - Type 6L
x
000008
g
I
81.
No.
Description of Materials
220/66/ 1 1 kV Transformer Type 2T6(as per annexure
RPPI-SASl
220/ 1 10/ 1 1 kV Transformer Type 2Tl(as per annexure
iii
RPPI-SASl
ii
Unit
Amount in
Nos.
20.07
Nos.
20.22
iv 220 kV Bus Coupler Type 2BC(as per annexure RPPI-SAS)
Nos.
5.55
220 kV Bus Bar Protection Type 2BBA(as per annexure
RPPI-SASl
Nos.
24.5
vi 1 10 kV line panel - Type lL(as per annexure RPPI-SAS)
Nos.
8.37
Nos.
4.97
v
vii 1 10 kV Bus Coupler panel - Type lBC
1 10/ 1 1 kV Transformer panel - Type lTl(as per annexure
viii
RPPI-SASl
ix 66 kV line- Type 6Lfas per annexure RPPI-SAS)
Nos.
16.01
Nos.
10. 14
66 kV Bus Coupler - Type 6BC(as per annexure RPPI-SAS)
Nos.
7.08
Nos.
15.80
Nos.
6.82
Nos.
77.81
M.T.
0.83
M.T.
0.68
M.T.
0.92
x
66/ 1 1 kV Transformer- Type 6Tl(as per annexure RPPISAS)
1 lkV line type- lL (as per annexure RPPI-SAS) (Provision
xii
for 2 feeders to be made in one panel)
xi
xiii Sub-station automation system
Rs
Lakhs
TOWERS:
3
Fabrication, galvanising and supply of High tensile steel
tower materials
Fabrication, galvanisation and supply of mild steel tower
ii
materials
iii Supply of e:alvanised Bolts & Nuts
i
Amount in Rs.
ACCESSORIES:
4
Set
306
ii Number Plates/Circuit Plates
No.
1 16
iii Danger Plates/Caution Plates ( 1 No. per tower)
No.
129
iv Earth Bond 300 mm Long
No.
277
v Earth Bond 450 mm Long
No.
318
a) 9 Mtr. Long 145kgs
Nos.
5941
b) 9 Mtr. Long, 150Kgs working load
Nos.
72 10
i
Phase Plates (Set of 6 per tower)
RCC POLES:
5
RIGID BUS WITH TAPS & CLAMPS
6
A RIGID BUS:
Mtrs.
1291
b) 75mm Size --- l lOkV Side
Mtrs.
1291
�a
cJ'
�
¢1
tr
t
Material +
Labour
i) Aluminium Tube Conforming to 6340 WP of IS5082 / l 969 f BS 1600-Sch.40) of followine: sizes.
a) 75mm Size --- 220kV Side
�T.C}..· *
�}
�
aooc:o·9
, ..
\\u
/\
SI.
No.
.
Description of Materials
Unit
Amount in Rs
c) 63mm Size --- 66kV Side
Mtrs.
909
d) 50mm Size --- 33kV Side
Mtrs.
509
e) 50mm Size connecting isolator to vertical tap --- 66kV
Side
Mtrs.
572
f) 38mm Size connecting isolator to vertical tap --- 33kV
Side
Mtrs.
. 405
ii) TAPS:
a) Inverted 'V' taps made of 63mm Aluminium Tube (BS1600) of 2500mm vertical height for vertical portion and
cross bus on 220kV Side with rounded off end.
Nos.
4547
Nos.
4158
Nos.
2424
Nos.
31 10
a) Rigid Type
Nos.
1 18 1
b) Expansion Type
Nos.
239 1
c) Sliding Type
Nos.
1 165
a) Rigid Type
Nos.
829
b) Expansion Type
Nos.
2264
c) Sliding Type
Nos.
868
a) Rigid Type
Nos.
829
b) Expansion Type
Nos.
2263
c) Sliding Type
Nos.
868
b) 75mm
Nos.
532
c) 63mm
Nos.
310
d) 50mm
Nos.
310
b) Straight taps made of 63mm Aluminium Tube (BS-1600)
of 1750mm vertical height for vertical portion and cross
bus on l lOkV side with rounded off end.
c) Straight taps made of 50mm Aluminium Tube (BS- 1600)
of 1250mm vertical height for vertical portion and cross
bus on 66kV side with rounded off end.
d) Straight taps made of 38mm Aluminium Tube (BS- 1600)
of lOOOmm vertical height for vertical portion and cross
bus on 33kV side with rounded off end.
iii) CLAMPS:
Post insulator Clamp suitable for 75mm Aluminium pipe
A
and post insulators Solid core type.
Post insulator Clamp suitable for 63mm Aluminium pipe
and post insulators Solid core tvpe.
B
c
Post insulator Clamp suitable for SOmm Aluminium pipe
and post insulators Solid core type.
D Corona Bell Suitable for Aluminium pipe of Size
�;
�er.era/4i.
9'
:f. �
���
�
!o�.::
)
iii'
.... ,, •
--n
.,o
·�c
.,_'-L.
� �
·--'":'.'":'-:-""--::...-�
•
.£)
�'!fl�·!S'"
000010
'. '
'·
'
. I
' .
;_t
'r
SI.
No.
Description of Materials
Unit
Amount in Rs
Lakhs
CONDUCTORS:
7
a) Coyote ACSR
KM
b) Lynx ACSR
KM
KM
d) Moose ACSR
KM
3.71
f) AAAC - Moose
KM
3.9 1
f) 7 /3. 15 mm G.I. Wire for ground conductor
KM
0.46
g) 7 /3.65 mm G.I. Wire for ground conductor
KM
0.62
a) Solid Core Insulators 220 kV
No.
21053
b) Solid Core Insulators 1 10 kV
No.
8254
c) Solid Core Insulators 66kV
No.
4139
d) Solid Core Insulators 33kV
No.
2529
e) Disc Insulator 70 KN
No.
402
f) Disc Insulator 90 KN
No.
415
No.
534
h) Disc Insulator 160 KN
No.
801
i) 33 kV Pin Insulator Shell with pin
No.
388
j Pins for above
No.
155
k) Solid core long rod insulators 90KN
No.
42 14
1) Solid core long rod insulators 120KN
No.
17899
m) Solid core long rod insulators 160KN
No.
18492
n) 220kV Polymer disc insulator
Set
8010
o) l lOkV Polymer disc insulator
Set
33 18
p) 66kV Polymer disc insulator
Set
2074
Amount in Rs.
Lakhs
TELECOMMUNICATION EQUIPMENTS
A Wave Trap:
b) 0.5 mH 800A ( Suspension tvue )
c) 1.0 mH 2000A
B
c
2.94
Amount in Rs.
-
g) Disc Insulator 120 KN
9
1.45
"
c) Drake ACSR
INSULATORS:
8
0.95
Set
1.5 1
Set
4.78
Set
1.95
Set
5.83
Couplini:t Capacitors:
l)Coupling Capacitors 8800 pf/4400 pf with clamps
PLCC Terminals {Carrier cabinets):
a) Twin Channel
000011
Sl.
N o.
Description of Materials
b) Single Channel
Amount in Rs
Unit
Lakhs
Set
4.85
a) Coupling Ph/Ph
Set
1.22
b) Coupling Ph/Gnd
Set
0.77
Kms
1.22
Trunk/E&M/Line 8/8/16
No
3.98
Trunk/E&M/Line 8/8/8
No
3.07
4 commands
No
2.14
2 commands
No
1.36
No
0.01
D Coupling Device with protective device:
E HF Co-axial Cable
75 ohms
F EPAX for PLCC:
G Protection couplers:
H Telephone 2 wires:
I
J
Amount in Rs.
Over Head Cables (Unshielded)
a) 20 Pair PVC/OH telephone Cable 0.5 1mm dia conductor
Mtr.
36
b) 5 Pair PVC/OH telephone Cable 0.5 1 mm dia conductor
Mtr.
21
5 Pair PVC telephone Cable 0.5 1mm dia conductor with
shield
Mtr.
31
Mtr.
7
a)Push button telephone
Per Unit
357
b)Plan 103 P.B. telephone ( 1 Main & 1 Extn)
Per Set
2265
c)Panasonic Plan 103( 1 Main & 1 Extension)
Per Set
8352
a) lOpair
No.
175
b)20pair
No.
206
c)50pair
No.
360
d) lOOpair
No.
515
Nos.
139
Nos.
283
K 0.9 1mm Copper drop wire
L Telephone Instruments:
M KRONE BOX:
N a) Krone modules for 1 0 pairs isolation type
b) Krone modules for 100 pairs( lONos each row)
000012
SI.
No.
p
Description of Materials
Unit
1) 20 pair
Mtrs.
100
Per kit
764
No
1053000
1) Portable(mobile) Oil Pump ( 1/2 HP Air Pump 500 to
1000 l!allons)
No
10305
2) Telescopic Ladder aluminium 6 Mtr. Height
No
22328
3) Ring spanners-12Nos per set
Set
791
4) Tube Spanners- 12Nos per set
Set
396
5) Pipe wrench 24 inches size
No
791
6) Pipe wrench 18 inches size
No
459
7) Double end spanner- 12Nos per set
Set
422
8) Hack saw frames +B l85
Nos.
185
9) Hydraulic crimping tool upto lOOOSq.mm
Nos.
35495
10) Rubber hand gloves 15kV tested
Pair
149
1 1 ) Hand Torch 5 celled
No
447
12) Hand Torch 3 celled
No
378
13) Insulated cutting pliers 12 inches size
No
200
No
142
15) Line live tester
No
158
16) Screw driver 18 inches size
No
148
17) Screw driver 12 inches size
No
95
18) Hammer 8 Lbs.
No
253
19) Hammer 2 Lbs.
No
127
20) Chain pulley block 5Ton Capacity
No
246 18
21) Hydraulic Jack 5Ton Capacity
No
3587
22) Pipe derrick
No
14243
23) Allen keys
Set
243
24) Box spanners- 12Nos per set
Set
3640
25) Transil oil Dielectric Breakdown testkit
No
74425
26) Insulation Tester (Megger) 2.5kV-5kV
No
38930
Rs
Straight through joint kit for J.F.U.G.Cable of 0.63mm dia
Conductor, TSF (Thermo Shrink Filled Closure type)
1) 20 pair TSF- 1
Q Remote terminal unit
10
Amount in
TOOLS AND PLANT:
14) Insulated cutting pliers 8 in size
,
000013 ,,
-
I�
SI.
Description of Materials
No.
Unit
Amount in
27) Insulation Tester (Megger) 500V rating
No
10878
28) SF6 gas leak detector
No
33205
29) Multimeter electromechanical type
No
2290
30) Multimeter electronic type
No
4981
31) Hydrometer
No
458
32) D.C.Volt meter range-3V to +5V
No
1374
33) Hydrometer syringe suitable for vent holes
No
458
34) Specific gravity correction chart
No
458
35) Wall mounting type holder for Hydro·meter
No
1374
36) Earth resistance tester
No
143 13
37) Arc welding machine ( 10 kVA)
No
2 1 183
38) Thermometer with wall mounting holder
No
1374
39) Rubber appron
No
973
40) Pippette
No
401
41) Protective Goggle
No
458
42) Acid Resisting jars (4 print capacity)
No
458
Pair
1088
44) Glass Funnel
No
344
45) Hickery rods
No
2748
46) Grounding sticks
No
332 1
47) Manilla rope '1"
Mts.
( 100)
1 1 107
48) Manilla rope '3/ 4"
Mts.
( 100)
1 1 107
49) Files of sizes
No
4408
50) Portable drilling M/C with stand (heavy duty)
No
2 1755
51) Hand drilling M/C
No
10878
52) Safety belts
53) Safety helmets
No
No
618
229
54) Steel Measuring tape 30 Mtrs.
No
630
55) Steel Measuring tape 15 Mtrs.
56)Man:ual crimping tool upto 400sqmm
No
No
452
2279
No
Pair
1660
1592
No
372 13
43) Rubber shoes knee height
57)Rain coat with dick back
58)Gum Boots
59)Bolt cutter-hydraulic
�eral Mq/J.
.
Ql
0'll
����
Q.
IJ.)
Cl
\•
0•11')
Cl>
g.
�1-;
�;q.l.>f:��
-
Rs
000014
Amount in Rs.
Sl
No.
Description of Materials
Unit
Drake ACSR Lynx ACSR
11
Coyote
ACSR
Rabbit
ACSR
Ground
Conductor
628
A HARDWARE
1
Single Tension Clamps with
arcing horns
Nos.
1913
835
764
600
2
Double Tension Clamps with
arcing horns
Nos.
3407
2377
2208
1965
3
Single Suspension Clamps
with arcing horns
Nos.
1 195
1014
938
625
4
Double Suspension Clamps
with arcing horns
Nos.
2268
1935
1 9 13
1716
5
P.G. Clamps
Nos.
658
395
274
96
205
6
M.S,.C. Joints
Nos.
585
340
316
210
233
7
Pre-formed Armour Rods
Nos.
1702
643
55 1
445
8
Repair Sleeves
Nos.
450
301
153
1 12
9 Vibration Damper
Nos.
785
5 16
434
466
Nos.
4028
3870
3870
3870
Nos.
572
568
5 10
411
10
Automatic Come - along
Clamp
1 1 Pad Clamps
�e•,,'IJ.\ IVl8/]��
(!) �
�
I !=;�
�*
\t
0
�
o""·'� "?.g.
�!
'"o/,1
1.,;_
•
.Lo
'
662
157
2121
000015
'
"
lb
I
SI.
Description of Materials
No
Qty
Amount in
Rs.
Hardware Clamps for Station materials
Bolted Type tension Clamp
B
c
1) Twin Falcon ACSR Conductor 120KN 20mm
Nos.
2593
2) Twin Drake ACSR Conductor 120KN 20mm
Nos.
2231
3) Twin Moose ACSR Conductor 120KN 20mm
Nos.
2323
4) Twin Falcon ACSR Conductor 90KN 16mm
Nos.
2102
5) Single Falcon ACSR Conductor 120KN 20mm
Nos.
1366
6) Twin Drake ACSR Conductor 90KN 16mm
Nos.
2027
7) Single Falcon ACSR Conductor 90KN 16mm
Nos.
1324
8) SingleDrake ACSR Conductor 120KN 20mm
Nos.
1280
9) SingleDrake ACSR Conductor 70/90KN 16mm
Nos.
1235
lO)Single LYNX ACSR Conductor 70/90KN 16mm
Nos.
719
l l)Single Coyote ACSR Conductor 70/90KN 16mm
Nos.
675
12) Single Rabbit ACSR Conductor 70/90KN 16mm
Nos.
508
Nos.
1944
1) Twin Falcon ACSR Conductor 90KN 16mm
Nos.
2395
2) Twin Moose ACSR Conductor 90KN 16mm
Nos.
2215
3) Twin Drake ACSR Conductor 90KN 16mm
Nos.
2092
4) Single Falcon ACSR Conductor 90KN 16mm
Nos.
978
5) SingleDrake ACSR Conductor 70/90KN 16mm
Nos.
857
6) Single LYNX ACSR Conductor 70/90KN 16mm
Nos.
642
Wedged clamps
1) Single Tension Clamp Compression type Drake
ACSR
D
Bolted Type Suspension Clamp
fll"-a\Man�
lb�
�
I !j�
�
�
�
o\•
o*
.o+•'').
""
�
�g.
ii!
��·*
-'tP.r.C
I
000016
SI.
No
E
Qty
7) Single Coyote ACSR Conductor 70/90KN 16mm
Nos.
582
8) Single Rabbit ACSR Conductor 70/90KN 16mm
Nos.
466
Nos.
658
1) Twin Falcon ACSR Conductor 127mm 220KV
Nos.
972
2) Twin Moose ACSR Conductor 127mm 220KV
Nos.
831
Nos.
779
Nos.
561
Nos.
514
Nos.
480
Nos.
444
Nos.
407
1) Twin Falcon 220KV
Nos.
359
2) Twin Moose 220KV
Nos.
338
3) Twin Drake 220/110/66KV
Nos.
322
1) Twin Falcon to Single Drake
Nos.
1037
2) Twin Moose to Single Drake
Nos.
781
3) TWin Drake to Single Drake
Nos.
669
4) Single Falcon to Single Drake
Nos.
421
5) Single Drake to Single Drake
Nos.
370
6) Single Drake to Single Lynx
Nos.
346
Post insulator Clamps
3) Twin Drake ACSR Conductor 127 mm
220/110/66KV
4) Single Falcon ACSR Conductor 220/110/66KV
5) Single Drake ACSR Conductor 127/76mm,
220/110/66/33KV
6) Single Lynx ACSR Conductor 127/76mm,
110/66/33KV
7) Single Coyote ACSR Conductor 127/76mm,
66/33KV
8) Single Rabbit ACSR Conductor 76mm, 33KV
G
H
Rs.
Hardware Clamps for Station Materials
1) Ground Wire Clamp 7 /3.15mm 2 bolt
F
Amount in
Description of Materials
Spacer Clamp for ACSR Conductors
Requirement of Power Connectors 'T' Clamps for
ACSR Conductors.
000017
SI.
No
I
J
K
Amount in
Description of Materials
Qty
7)Single Drake to Single Coyote
Nos.
325
8) Single Lynx to Single Lynx
Nos.
273
9)Single Coyote to Single Drake
Nos.
325
10) Single Lynx to Single Drake
Nos.
346
11) Single Coyote to Single Coyote
Nos.
259
1) Twin Drake
Nos.
940
2) Single Drake
Nos.
567
3) Single Lynx
Nos.
437
4) Single Coyote
Nos.
376
1) 63mm nominal diameter x 73.03mm
Nos.
1009
2) 50mm nominal diameter x 60.03mm
Nos.
860
1) Rabbit to Coyote ACSR Conductor
Nos.
704
2) Rabbit to Lynx ACSR Conductor
Nos.
1147
3) Rabbit to Drake ACSR Conductor
Nos.
1970
4) Coyote to Coyote ACSR Conductor
Nos.
1032
5) Coyote to Lynx ACSR Conductor
Nos.
1261
6) Coyote to Drake ACSR Conductor
Nos.
1444
7) Lynx to Lynx ACSR Conductor
Nos.
1277
8) Lynx to Drake ACSR Conductor
Nos.
1512
9) Drake to Drake ACSR Conductor
Nos.
1939
Nos.
1199
11) Rabbit to 2 hole paddle ACSR conductor-895A
Nos.
1303
12) Coyote 2 hole paddle ACSR Conductor-6 lOA
Nos.
1459
Rs.
Power Connectors. Terminal connector clamps for
ACSR Conductor
Power connectors. Expansion type terminal
connectors suitable for Aluminium pipes
C type Wedge Connectors
10) Rabbit to 2 hole paddle ACSR Conductor
o\r
�
P.
o
::;,
�I
-·
�'·!.'!?� T.C�· ,$
..., ......,,,.•,<...
*,_.
.._......
-
6 lOA
000018
SI.
No
Amount in
Description of Materials
Qty
13) Coyote 2 hole paddle ACSR Conductor-895A
Nos.
1668
14) Coyote 2 hole paddle ACSR Conductor- 1400A
Nos.
3815
15) Coyote 4 hie Paddle ACSR Conductor-610A
Nos.
1616
16) Coyote 4 hole paddle ACSR Conductor-895A
Nos.
1731
17) Coyote 4 hole paddle ACSR Conductor-1400A
Nos.
3701
18) Lynx 2 hole paddle ACSR Condcutor-610A
Nos.
2064
19) Lynx 2 hole paddle ACSR Conductor-895A
Nos.
2064
20) Lynx 2 hole paddle ACSR Conductor-1400A
Nos.
3909
21) Lynx 4 hole paddle ACSR Conductor-610A
Nos.
2346
22) Lynx 4 hole paddle ACSR Conductor-895A
Nos.
2450
23) Lynx 4 hole paddle ACSR Conductor-1400A
Nos.
3909
24) Drake 2 hole paddle ACSR Conductor-6 lOA
Nos.
3753
25) Drake 2 hole paddle ACSR Conductor-895A
Nos.
3753
26) Drake 2 hole paddle ACSR Conductor-1400A
Nos.
4159
27) Drake 4 hole paddle ACSR Conductor-610A
Nos. -
2606
28) Drake 4 hole paddle ACSR Conductor-895A
Nos.
3075
29) Drake 4 hole paddle ACSR Conductor-1400A
Nos.
4159
30) Rabbit to Rabbit ACSR Conductor
Nos.
417
31) Drake to Moose ACSR Conductor
Nos.
2971
Rs.
000017
SI.
No
Qty
32) Drake to Falcon ACSR Conductor
Nos.
8861
33) Moose to Moose ACSR Conductor
Nos.
3075
34) Moose to Falcon ACSR Conductor
Nos.
9069
35) Falcon to Falcon ACSR Conductor
Nos.
9174
Nos.
5473
Nos.
5473
Nos.
5473
Nos.
5473
Nos.
14178
Nos�
14178
1) Numerical distance relay for 220 kV system
Nos.
211021
2) Numerical distance relay for 66 kV system
Nos.
309686
Nos.
351000
Nos.
19481
5) Restricted Earth fault relay
Nos.
11700
6) Single pole over current/ Earth fault relay
Nos.
7125
7) Trip circuit Supervision relay
Nos.
7184
8) Auxiliary relay -2 element
Nos.
5792
9) Master trip relay
Nos.
9828
36) Moose 2 hole paddle ACSR Conductor & 2 hole
paddle-895A
37) Moose 2 hole paddle ACSR Condcutor & 2 hole
paddle-1400A
38) Moose 4 hole paddle ACSR Conductor & 4 hole
paddle-895A
39) Moose 4 hole paddle ACSR Conductor & 4 hole
paddle-1400A
40) Falcon 2 hole paddle ACSR Conductor & 2 hole
paddle-1400A
41) Falcon 4 hole paddle ACSR Conducotr & 4 hole
paddle-1400A
12
Amount in
Description of Materials
Rs.
Relays:
3) Static/Digital/Numerical Differential relay for
Transformer protection for SAS station
4) Single pole Directional over current/ Earthfault
relay
00002'.J
2/
SI.
No
Description of Materials
10) Single pole Non-directional over current/
Qty
Amount in
Rs.
Nos.
8681
11) Auxiliary relay -3 element
Nos.
4753
12)Under frequency relay
Nos.
70200
13) Line Differential relay
Nos.
351000
Earthfault relay with HS
000021
SI.
Material
No
13
Unit
Amount in
Rs.
A MISCELLENEOUS ITEMS
a) l lkV GOS D/B 1200A
Set
34340
b) l lkV GOS D/B 800A
Set
31089
c) l lkV GOS D/B 400A
Set
24358
d) 1 lkV GOS S/B 400A
Set
18855
e) l lkV GOS S/B 200A
Set
12355
f) 1 lkV 400A, Special roster GOS
Set
15444
g) 1 lkV HG Fuse unit
Nos.
6 13
h) 9kV, 5kVA lightning Arrestor (Metal oxide type)
Nos.
636
i) 1 1 kV UG Cable 1 Core 1000 sq.mm
Km
980000
ii) 1 1 kV UG Cable 3 Core 400 sq.mm
Km
1675000
iii) 1 1 .kV UG Cable 3 Core 240 sq.mm
Km
1209000
iv) 1 1 kV UG Cable 3 Core 95 sq.mm
Km
646580
i) 3 x 95 Sq.mm
Nos.
7187
ii) 3 x 240 Sq.mm
Nos.
888 1
iii) 3 x 400 Sq.mm
Nos.
9045
iv) lx 1000 Sq.mm
Nos.
7576
i) 3 x 95 Sq.mm
Nos.
3477
ii) 3 x 240 Sq.mm
Nos.
4268
iii) 3 x 400 Sq.mm
Nos.
4905
iv) lx 1000 Sq.mm
Nos.
3835
i) 3 x 95 Sq.mm
Nos.
4253
ii) 3 x 240 Sq.mm
Nos.
4268
iii) 3 x 400 Sq.mm
Nos.
5036
iv) lx 1000 Sq.mm
Nos.
4330
B HV CABLES
1 lkV JOINTS AND POT HEADS
14
A
Heat Shrinkable type transition jointing kit for XLPE
Cable
B Cold Shrinkable type termination kit for XLPE Cable
a) Indoor
b) Outdoor
000022
SI.
Material
No
13
Unit
Amount in
Rs.
A MISCELLENEOUS ITEMS
c
D
Cold Shrinkable type transition jointing kit for XLPE
Cable
i) 3 x 95 Sq.mm
Nos.
17996
ii) 3 x 240 Sq.mm
Nos.
16724
iii) 3 x 400 Sq.mm
Nos.
17369
iv) lx 1000 Sq.mm
Nos.
7744
i) 3 x 95 Sq.mm
Nos.
22 19
ii) 3 x 240 Sq.mm
Nos.
2736
iii) 3 x 400 Sq.mm
Nos.
6231
iv) lx 1000 Sq.mm
Nos.
1892
i) 3 x 95 Sq.mm
Nos.
1987
ii) 3 x 240 Sq.mm
Nos.
2736
iii) 3 x 400 Sq.mm
Nos.
945 1
iv) lx 1000 Sq.mm
Nos.
2 129
i) 3 x 95 Sq.mm
Nos.
4674
ii) 3 x 240 Sq.mm
Nos.
5283
iii) 3 x 400 Sq.mm
Nos.
638 1
iv) lx 1000 Sq.mm
Nos.
5539
i) 45 liters capacity
Nos.
1 1224
ii) 9 liters capacity
Nos.
2 157
b)Water type (Gas pressure type) 9 liters capacity
Nos.
1849
c) Carbondioxide type 6 liters capacity
Nos.
6 106
1 lkV Heat Shrinkable Cable termination kit for XLPE
Cable
a) Indoor
b) Out door
E
15
1 lkV Heat Shrinkable Straight through jointing kit for
XLPE Cable with Copper Lugs & Aluminium Ferrules
Fire Fightning equipments with necessary mounting
stands
a) Foam extinguishing type
d) Stand type
000023
SI.
Material
No
13
Unit
Amount in
Rs.
A MISCELLENEOUS ITEMS
i) G.I.Buckets 9 Liters capacity
Nos.
252
ii) Steel stands
Nos.
938
e) Nitrogen Injection fire extinguishing system for
lOOMVA and above Power Transformers
Set
859163
f) Nitrogen Injection fire extinguishing system for Power
Transformers below lOOMVA
Set
675036
16
ELECTRIC GENERATING SET COMPRISING OF;
50KW/62.5kVA Diesel Generating Set rated at
50KW/62.5kVA 4 1 5V, 0.8PF, Mounted on a Base Frame,
Complete with Inbuilt Fuel Tank and battery 1 No. 12V &
Inbuilt Standard Manual Control Panel with Acoustic
Enclosure - NAL Approved.D.G. Set 63kVA Capacity with
AMF panel
Nos.
576000
17
Station Auxiliary Transformer with oil, cable termination
type on both HT & LT outdoor type 100 kVA, l lkV/433 V,
3 phase Dyl l
Nos.
195574
a) 250kVA
Nos.
288800
b) 100 kVA
Nos.
195574
a) 250kVA
Nos.
182 19+702
b) lOOkVA
Nos.
10400+28 1
a) 25mm width
Mtrs
383
b) 50mm width
Mtrs
766
c) 75mm width
Mtrs
1 148
d) lOOmm width
Mtrs
153 1
B) Epoxy shroubs suitable for 1 lkV outdoor bus
Mtrs
2024
A
Supply and errection of 3 Ph 1 lkV/433 V distribution
Transformer with copper windings
B Supply & Fixing LT distribution box
18
A 1 lkV Insulation Tapes (HV BT Tapes)
000024
Sl.
No
Material
Unit
Supply rates
in Rs. Lakhs
Labour
rates in Rs.
19 400kV SUB-STATION MAIN EQUIPMENTS
As per the
weight or the
transformer
As per the
weight or the
reactor
1
167 MVA, 400/220/33 kV single phase Inter-connecting
transformer(ICT)
Set
5 17.24
2
420 kV Class, 63MVAR Bus Reactor as per bid specification
along with Neutral ground Transformer
Nos
344.48
Set
32.8
50588
i) 3-Pole with single earth switch.
Set
8.62
16864.38
ii) 3-Pole without earth switch.
Set
7.07
16188. 12
Set
7.03
17537. 13
Nos
7.27
9227.79
i) 390kV Class
Nos
1.08
9227.79
ii) 120 kV Class(For NGT)
No.
Circuit breaker SF6 type, with operating mechanism and
marshalling box along with associated support structure and
terminal connector etc.. as oer bid soecifiaction.
Al 420 kV Class 40 kA, 2000A !without closin� resistors)
Isolators with operating mechanism and marshalling boxes,
4
terminal connectors etc as oer bid soecifications.
3
A) 420kV, 40kA 3 150A pantograph type
B) 420kV, 40kA 3 150A Centre break type
i) 3-Pole with double earth switch.
5
Current transformers having 5 Cores, with marshalling boxes,
teminal connectors etc., as per bid specification.
A) 420kV Class, 40kA CT with ratio 3000-2000/ 1-1 & 500200/ 1 - 1 - 1
6
Surge Arresters with insulating base, surge monitor, terminal
connectors etc as per bid specifications.
Capacitor Voltage transformers having 5 Cores, with
7 marshalling boxes, teminal connectors etc., as per bid
soecification.
Nos
3.99
a) Back-up control panel for 400 kV reactor
Set
3.34
10792.08
b) Relay panels for 400 kV Reactor
Set
14.0 1
10792.08
c)400kV Line - type 4L (As per ANNEXURE Feeder Panel SAS)
Nos
22.05
10792.08
d)400/220/33kV Trasformer - Type 4T (As per ANNEXURE
Transformer Panel - SAS)
Nos
27.09
10792.08
i) For 400 kV Panels
Nos.
2.02
ii) For 220 kV Panels
Nos.
1 .77
A) 420kV Class, 8800PF
8 Control & Relay equipment complete as per bid specification
e)Marshalling bay kiosks.(as per technical specifications,
along with Air conditioning system).
9 BUS AND HARDWARE FITTINGS:A
Aluminum tube, confirming to 6340WP of IS 5082, 1969,
BS 1600Sch 40 of size lOOmm (4") Size
�lJ\anaUe�-
Mtres
Amount in Rs.
2282
-
� �::::: '
I ]!-� Q4Y\� ff)
J
(!j
t\,
.
o\�
o*
tu
,frs:r.c:'J>::j'Jl
..-.._�,,#
000025
Unit
Supply rates
in Rs.
Hardware set for 400kV Double Tension string assembly with
double anchoring points including turn buckle, corona ring
B
and tension clamp and complete set suitable for Twin moose
ACSR bundle with 450mm sub conductor spacing.
Set
18559
Hardware set for 400kV Single suspension string insulators
assembly including corona ring, suspension clamp and
c
complete set etc., suitable for Twin moose ACSR bundle with
450mm sub conductor snacine-.
Set
9593
Set
16484
Set
7228
Set
82 13
Set
3684
Nos
35900
Nos
32 14
Nos
3318
Sl.
No
Material
Labour
rates in Rs.
Hardware set for 220kV Double tension string assembly with
D double anchoring points including turn buckle arcing horn,
tension clamps and complete set etc suitable for
a.Quadruple moose ACSR bundle with 250mm sub-conductor
spacinf!'.
b.Twin moose ACSR bundle with 250mm sub-conductor
spacinf!'.
Hardware set for· 220kV single suspension string insulator
E ·assembly including arcing horn, suspension clamp and
complete set etc., suitable for
a.Quadruple moose ACSR bundle with 250mm sub-conductor
spacing.
b.Twin moose ACSR bundle with 250mm sub-conductor
spacing.
F 400kV Class Bus Post Insulators
G 400kV clamns and connectors
Terminal connector for CB to receive 4" IPS Al. tube flexible
i
tvpe
Terminal connector for CT to receive 4" IPS Al. tube flexible
ii
tvpe
iii Terminal connector for Centre Break Isolator to receive
Nos
a) 4" IPS Al. tube flexible type
Nos
32 14
b) Twin Moose ACSR conductor suitable for vertical take off
450 mm spacing
Nos
1995
a) 4" IPS Al. tube Expansion type
Nos
3 1 67
b) 4" IPS Al. tube Rigid type
Nos
2885
c) 4" IPS Al. tube Sliding type
Nos
1709
C' type wedge connector suitable for Moose ACSR to Moose
ACSR
Nos
4133
a)T' Clamp suitable for 4" IPS Al. tube to twin moose ACSR
conductor
Nos
23 1 1
b)T clamp sutable for 4"Al.tube to 4" Al.tube.
Nos
2269
a)Flexible
Nos
2354
b)Rigid
Nos
1278
Nos
1884
Nos
16 1 1
iv Terminal Connector for BPI to receive
v
vi T' clamps
vii
Spacers for Quadruple Twin moose ACSR conductor with
450mm spacing
Terminal connector for LA to receive ACSR twin moose
viii conductor suitable for horizontal/vertical take off with
450mm snacine-
ix Welding sleeve suitable for 4 inch IPS Al. tube
��"11an'We
�e;
;.";:;
���
Ib
�
-��
�
'·/,
01t oA••>
�
* kPTCl-·"'15-
·�
_?
·-
0·
000020
Unit
Supply rates
in Rs.
Nos
30 12
a} Twin Moose ACSR conductor
Nos
1961
b} 4" IPS Al. tube flexible type
Nos
3 132
a} 4" IPS Al. tube flexible type
Nos
30 12
b} 4" IPS Al. tube Rigid through type
Nos
1526
c} Twin moose ACSR conductor suitable for Vertical take off
250mm spacing
Nos
1373
d} Twin moose ACSR conductor suitable for horizontal take
off 250mm spacing
Nos
1373
Terminal Connector for CVT to receive 4" IPS Al. tube Rigid
type
Nos
1584
Nos
1590
a}4" IPS Al. tube (od: 1 14.3mm, ID:97. 18mm} Expansion type
Nos
4004
b} 4" IPS Al. tube Rigid type
Nos
1558
c} 4" IPS Al. tube Sliding type
Nos
1679
T' clamp suitable for 4" IPS Aluminium tube to twin moose
conductor
Nos
1744
SI.
No
Material
Labour
rates in Rs.
H 220kV Clamps and Connectors
i
Terminal connector for CB to receive 4" IPS Al. tube flexible
type
ii Terminal connector for CT to receive
iii Terminal Connector for isolator to receive
iv
v Terminal Connector for CVT to receive Twin Moose ACSR
vi
vii
Clamps for Aluminium tube suitable for BPI for both main
bus & interconnecting bus
viii T clamp suitable for Quadruple Moose ACSR to 4" IPS Al. tube
2573
ix
C' type wedge connector suitable for Quad Moose ACSR to
Quad Moose ACSR
4058
x
C' type wedge connector suitable for Quad Moose ACSR to
Twin Moose ACSR
4058
xi
Spacers for twin ACSR Moose Conductor with 250mm
spacing
a} Flexible
1092
b} Rigid
435
Terminal connector for LA to receive ACSR twin Moose
xii conductor suitable for horizontal take off with 250mm
sJ>acin2
1373
xiii Welding sleeve suitable for 4 inch IPS Al. tube
1611
xiv Corona Bell suitable for 4 inch IPS Al. Tube
532
I
72 kV clamps and connectors
i
Terminal connector for PT to receive 2.5 IPS Al. Tube rigid
type
Nos.
1093
ii
Terminal connector for isolator to receive 2.5 IPS Al. Tube
flexible type
Nos.
23 1 1
iii
Clamps for Aluminium tube suitable for BPI for both main
bus & interconnecting bus
00002T
Sl.
No
Unit
Supply rates
in Rs.
a)2.5 IPS Al.Tube(od: 1 14.3mm, ID: 97. 18 mm) Expansion
type
Nos.
3279
b) 2.5 IPS Al. Tube Rigid type
Nos.
1009
c) 2.5 IPS Al. Tube Sliding type
Nos.
1 12 1
iv Welding sleeve suitable for 2.5 inch IPS Al. tube
Nos.
51 1
v Corona Bell suitable for 2.5 inch IPS Al. Tube
Nos.
250
Material
vi
Straight tap suitable for connecting 2.5 inch IPS Al. tube to
connect 33kV Main bus to 33kV equipment bus
Nos.
1247
vii
T·Clamp suitable for connecting 2:5 IPS Al. tube of 2.5" IPS
Al. tube
Nos.
2353
Labour
rates in Rs.
Amount in
Rs.Lakhs
10 Insulator with hardware for Twin Moose ACSR conductor
a) Single suspension fittings with 23 Nos. of 120KN
insulators and hardware set
Set
0.26
b) Double suspension fittings with 2x23 Nos. of 120KN
insulators and hardware set
Set
0.47
c) Single Tension fittings with 24 Nos. of 160KN insulators
and hardware set
Set
0.3 12
d) Double Tension fittings with 2x24 Nos. of 160KN
insulators and hardware set
Set
0.579
e) Pilot insulators fittings with 23 Nos. of 120KN Disc
insulators and hardware set
Set
0.225
a) Mid span compression joint
No
0.00933
b) Repair sleeves
No
0.00398
c) Vibration dampers
No
0.00898
d) Bundle Spacers for Line
No
0.00902
e) Rigid Spacers for Jumpers
No
0.0048 1
f) Balancing weights
No
0.26415
g) T-Connectors
No
0.0 1355
a) Mid span compression joint
No
0.00292
b) Compression type tension clamp
No
0.0057
c) Suspension clamps
No
0.00599
d) Repair sleeves
No
0.00292
e) Vibration dampers
No
0.00396
1 1 Accessories for Conductors
12 Hardware and Accessories for Ground Wire of size 7 / 3.66mm
13
Check survey & tower spotting
km
a) Hilly terrain
Per Km
3202
b) Plain Terrain
Per Km
2137
km
3579 1
14 Stringing of conductor & ground wire
a) Stringing of ACSR MOOSE conductor including Installing
insulator strings complete with necessary hardwares , and
fixing of conductor accessories,tower accessoreis etc.
a
�
'2i
�c;;-
�
�
I�
�- I
�'y·"*'�
� * k. P.i
000 02'3
Unit
Amount in
Rs Lakhs
1
127/220KV Single core 1000 Sq.mm., XLPE insulated, Lead
Sheathed overall PE Sheathed UG cable (E) grade,lcore,
circular, stranded, playing annealed compacted copper
conductor, screen on extruded semi conducting compound,
XLPE insulation; inulation screen of semiconducting
compound, non-woven water swellable semi conducting tape
extruded lead alloy (E) sheath, semi conducting bedding tupe
(s) helically applied copper wires open helix copper tape, nonwoven swellable tape, extruded PVC ST2 sheath conducive
coating & antitermite treated.high density poly-ethylene outer
sheathed copper cable as per Technical specifications.
Kms.
193.62
2
UOKV, 630Sq mm XLPE UG Cable UOKV (E) grade, 1 core,
Circular, stranded, plain annealed copper condutor, conductor
screen on extruded semi conducting compound, cross linked
polyethylene (XLPE) insulation, core screen, semi-conducting
water swellable layer, extruded lead alloy (E) sheath, semi
conducting bedding tapes, helically applied plain round copper
wire screen, plain copper tape in open helix, water swellable
tape with overall extruded high density polyethylene sheath,
coated with graphite etc., as per technical specification.
Kms.
78.80
3
UOKV, 400Sq mm XLPE UG Cable UOKV (E) grade, 1 core,
Circular, stranded, plain annealed copper condutor, conductor
screen on extruded semi conducting compound, cross linked
polyethylene (XLPE) insulation, core screen, semi-conducting
water swellable layer, extruded lead alloy (E) sheath, semi
conducting bedding tapes, helically applied plain round copper
wire screen, plain copper tape in open helix, water swellable
tape with overall extruded high density polyethylene sheath,
coated with graphite etc., as per technical specification.
Kms.
66.00
4
UOKV, 240Sq mm XLPE UG Cable UOKV (E) grade, 1 core,
Circular, stranded, plain annealed copper condutor, conductor
screen on extruded semi conducting compound, cross linked
polyethylene (XLPE) insulation, core screen, semi-conducting
water swellable layer, extruded lead alloy (E) sheath, semi
conducting bedding tapes, helically applied plain round copper
wire screen, plain copper tape in open helix, water swellable
tape with overall extruded high density polyethylene sheath,
coated with graphite etc., as per technical specification.
Kms.
56.00
·SI.No
20
I
Name of the equipment
EHV UG CABLES
EHV UG cables
0 0 0029
3o
Unit
Amount in
Rs Lakhs
5
66KV, lOOOsqmm XLPE UG Cable 66KV (E) grade, 1 core,
Circular, stranded, plain annealed Segmental compact type
miliken copper condutor, conductor screen on extruded semi
conducting compound, cross linked polyethylene (XLPE)
insulation, core screen, semi-conducting water swellable
layer, extruded lead alloy (E) sheath, semi conducting bedding
tapes, helically applied plain round copper wire screen, plain
copper tape in open helix, water swellable tape with overall
extruded high density polyethylene sheath, coated with
graphite etc., as per technical specification.
Kms.
106.00
6
66KV, 630sqmm XLPE UG Cable 66KV (E) grade, 1 core,
Circular, stranded, plain annealed Segmental compact type
miliken copper condutor, conductor screen on extruded semi
conducting compound, cross linked polyethylene (XLPE)
insulation, core screen, semi-conducting water swellable
layer, extruded lead alloy (E) sheath, semi conducting bedding
tapes, helically applied plain round copper wire screen, plain
copper tape in open helix, water swellable tape with overall
extruded high density polyethylene sheath, coated with
graphite etc., as per technical specification.
Kms.
68.16
7
66KV, 240sqmm XLPE UG Cable 66KV (E) grade, 1 core,
Circular, stranded, plain annealed Segmental compact type
miliken copper condutor, conductor screen on extruded semi
conducting compound, cross linked polyethylene (XLPE)
insulation, core screen, semi-conducting water swellable
layer, extruded lead alloy (E) sheath, semi conducting bedding
tapes, helically applied plain round copper wire screen, plain
copper tape in open helix, water swellable tape with overall
extruded high density polyethylene sheath, coated with
graphite etc., as per technical specification.
Kms.
45.44
II
EHV UG CABLES ACCESSORIES:
1
Out door type Cable end termination Procelain Design type
suitable for the above 127 /220KV (E) class single 1 core 1000
sq.mm lead sheathed cable including PVC Earthing cable.
Nos.
6.87
Nos.
2.96
Nos.
2.22
Nos.
1.71
SI.No
2
3
4
Name of the equipment
Outdoor type cable end termination suitable for 1 lOKV (E) 1 core, 630sqmm lead sheathed cable including PVC earthing
cable.
Outdoor type cable end termination suitable for l lOKV (E) 1 core, 400sqmm/240sqmm lead sheathed cable including PVC
earthine: cable.
Outdoor type cable end termination suitable for 66KV (E) 1 core, lOOOsqmm, Segmental compact type miliken copper
conductor, XLPE, lead sheathed cable including PVC earthing
cable.
00003]
Unit
Amount in
Rs Lakhs
Nos.
0.85
Nos.
5.62
7
Normal Straight Joints suitable for 1 lOKV(E) 1 -core 630
sqmm copper conductor XLPE, Lead sheathed cable, Complete
with all accessories as per technical specifications
Nos.
1.78
8
Normal Straight Joints suitable for l lOKV(E) 1 -core 400
sqmm/240sqmm copper conductor XLPE, Lead sheathed cable,
Complete with all accessories as per technical specifications
Nos.
1.46
Nos.
1.004
Nos.
0.85
Nos.
4.77
Nos.
0.47
Nos.
0.35
Kms.
1 .02
Kms.
0.61
SI.No
5
6
9
10
11
12
13
III
Name of the equipment
Outdoor type cable end termination suitable for 66KV (E) 1 core, 630/240sqmm, Segmental compact type miliken copper
conductor, XLPE, lead sheathed cable including PVC earthing
cable.
Normal Straight through joints suitable for 200KV 1 core pre
mounted desing lOOOsq.mm copper conductor, XLPE lead
sheathed cable. 127/220KV class single core 1000 sq.mm
cable as at SI. No. 1 .
Normal Straight Joints suitable for 66KV(E) 1 -core 1000
sqmm, Segmental compact type miliken copper conductor,
XLPE, Lead sheathed cable
Normal Straight Joints suitable for 66KV(E) 1 -core 630/240
sqmm, Segmental compact type miliken copper conductor,
XLPE, Lead sheathed cable
220kV :- Cross Bonding ,Link Boxes, Single phase out door
structure mounting type, with Temperature
Transducers,Thermocouplers, SVL/CCPU and PVC earthing
cable including lC lOOOSq mm cable as per the Technical
Snecifictions Clause 7.04.00 and its Sub-Clauses.
1 lOkV:-Link boxes, single phase outdoor structure mounting
type with SVL/CCPU and PVC earthing cable including the
cost of lC x 400 Sq mm/240sqmm copper cable
66kV:- .Link boxes, single phase outdoor structure mounting
type with SVL/CCPU and PVC earthing cable including the
cost of lxlOOO Sq.mm copper cable
OPTICAL FIBRES AND ACCESSORIES
2
12 Fibre Dual Window Mono Mode (DWMM) Optical Fibre Cable
as per Technical Sp ecifications.
Polyvinyl Lubricated Bond (PLB) pipe.
3
Straight Joint Kit for optical fibre cable.
Kit.
0. 1
4
Line Interface Unit for optical fiber cable.
Unit
0. 1
5
Collars for PLB pipe.
No.
0.001
1
0 0 003 1
Sl.
Name of the equipment
No
Unit
Supply Rates
in Rs Lakhs
2 1 Major works equipments for supply of GIS Modules
Metal encapsulated SF6 gas insulated
Switchgear 40KA rating suitable for indoor
installation or modular desie:n
1 220kV Line (U.G. Cable) Module:
No
202 . 1 9
Erection rates
in Rs Lakhs
1 . 13
Each Module comprising of the following:
SF6 circuit breaker Complete with
operating Mechanism, 2000A, 1
Phase/3uhase -lNo
Disconnector:
i) 3 Phase, Single Pole, Group operated
isolator switch complete with manual &
motor driven operating mechanism 1600A 3 Nos.
ii) 3 Phase, Single Pole, Group operated
maintenance earthing switch complete with
manual operating mechanism- 2 Nos.
2
iii) 3 Phase, Single Pole, fast acting, fault
make earthing switch complete with group
operated manual & motor driven operating
mechanism - 1 No.
Current Transformer: 5 Core, Multi ratio,
single phase current transformer 1200600/ 1-1- lA plus additional 2 cores of
1200/ 1-lA - f l Set) 3 Nos.
Sure:e Arresters - ( 1 Set) 3 Nos.
Cable end unit (Plug in type): 3 Phase,
Single pole, Plug in type cable termination 1 Run for 1000 Sq.mm for each phase - 1
fSet)
Bus Bar- Double bus arrangement:
i) Main Bus - 2500A
ii) Auxiliary Bus - 1600A
Local Control cubicle for GIS module, gas
monitoring device, barriers pressure
switches etc as required.
NOTE: The bus may be with single phase or
3 ohase enclosure.
220kV Line (0.H. line) Module:
Nos
171.75
1.13
Each Module comprising of the following:
SF6 circuit breaker Complete with
operating Mechanism, 2000A, 1
Phase/3uhase - lNo
000032
SI.
Name of the equipment
No
Unit
Supply Rates
in Rs Lakhs
Erection rates
in Rs Lakhs
Nos
132.92
1.02
Disconnector:
i) 3 Phase, Single Pole, Group operated
isolator switch complete with manual &
motor driven operating mechanism 1600A 3 Nos.
ii) 3 Phase, Single Pole, Group operated
maintenance earthing switch complete with
manual operating mechanism- 2 Nos.
iii) 3 Phase, Single Pole, fast acting, fault
make earthing switch complete with group
operated manual & motor driven operating
mechanism - 1 No.
Current Transformer: 5 Core, Multi ratio,
single phase current transformer 1200600 / 1 - 1- lA plus additional 2 cores or
1200/ 1-lA - f l Set} 3 Nos.
Single Phase SF6 duct & wall mounted SF6
to air bushing for outdoor connection or
conductor of overhead line - as required.
3
Bus Bar- Double bus arrangement:
eU Main Bus - 2500A
eiU Auxiliary Bus - 1600A
Local Control cubicle for GIS module, gas
monitoring device, barriers pressure
switches etc as required.
NOTE: The bus may be with single phase or
3 ohase enclosure.
220kV Bus Coupler Module:
Each module comprising or the following:
SF6 circuit breaker Complete with
operating Mechanism, 2000A, 1
Phase/3phase- 1 No.
Disconnector:
i) 3 Phase, Single Pole, Group operated
isolator switch complete with manual &
motor driven operating mechanism 1600A 2 Nos.
ii) 3 Phase, Single Pole, Group operated
maintenance earthing switch complete with
manual operating mechanism- 2 Nos.
Current Transformer: 3 Core, Multi ratio,
single phase current transformer 1200600/ 1-1- lA plus additional 2 cores of
12001 1-lA - f l Set} 3 Nos.
00 0 0 3 3
Sl.
Name of the equipment
No
4
Bus Bar- Double bus arrangement:
Main Bus - 2500A
Local Control cubicle for GIS module, gas
monitoring device, barriers pressure
switches etc as required.
NOTE: The. bus may be with single phase or
3 ohase enclosure.
Transformer Module:(For 1 50MVA - 220kV
Side)
Unit
Supply Rates
in Rs Lakhs
Erection rates
in Rs Lakhs
Nos
2 10.8
1.13
Nos.
88.29
0.92
Each module comprising or the following:
SF6 circuit breaker Complete with
operating Mechanism, 2000A, 1
Phase/3ohase - 1 No.
Disconnector:
i) 3 Phase, Single Pole, Group operated
isolator switch complete with manual &
motor driven operating mechanism 1600A 3 Nos.
ii) 3 Phase, Single Pole, Group operated
maintenance earthing switch complete with
manual operating mechanism- 3 Nos.
5
Current Transformer: 3 Core, Multi ratio,
single phase current transformer 600-300/ 1
1-lA plus additional 2 cores or 1200/ 1-lA f 1 Set) 3 Nos.
Surge Arresters (To be provided at the end
or SF6 ducts to be connected to SF6 Air
bushing for Transformer bushing
connection): 3Nos.l l setl
Bus Bar- Double bus arrangement:
il Main Bus - 2500A
ii) Auxiliarv bus- 1600A
Local Control cubicle for GIS module, gas
monitoring device, barriers pressure
switches etc as reauired.
Single phase SF6 ducts & SF6 to Air
bushing for outdoors connections - As
required
NOTE: The bus may be with single phase or
3 nhase enclosure.
Transformer Module(For 150MVA - 66KV
Side) :
Each module comprising or the following:
SF6 circuit breaker Complete with
operating Mechanism, 2000A, 1
Phase/3uhase -1 No.
�?>\ Ma�
�� ·
:i""
i ·��� �-5 )
�
�
::J C) \. 0A I \� o
·
Cl-
�*.t
. *
·�·P.T.C�-·
-....;;
-.._
;;..-
0000 3 4
SI.
Name of the equipment
No
Unit
Supply Rates
in Rs Lakhs
Erection rates
in Rs Lakhs
44.26
23.98
0.45
0.34
Disconnector:
i) 3 Phase, Single Pole, Group operated
isolator switch complete with manual &
motor driven operating mechanism 1600A 3 Nos.
ii) 3 Phase, Single Pole, Group operated
maintenance earthing switch complete with
manual operating mechanism- 3 Nos.
Current Transformer: 3 Core, Multi ratio,
single phase current transformer 16001000/ 1-1-lA - f l Set) 3 Nos.
Surge Arresters (To be provided at the end
of SF6 ducts to be connected to SF6 Air
bushing for Transformer bushing
connection): 3Nos I 1 set)
Bus Bar- Double bus arrangement:
i) Main Bus - 2500A
ii) Auxiliary bus- 1600A
Local Control cubicle for GIS module, gas
monitoring device, barriers pressure
switches etc as required.
Single phase /three phase SF6 ducts & SF6
to Air bushing for outdoors connections As required
NOTE: The bus and the equipmnets may be
with single phase or 3 phase enclosure.
6
PT Module
i) 220kV ( 1 for each bus)
ii) 66kV ( 1 for each bus)
Nos
Each module comprising of the following:
Disconnector:
i) 3 Phase, Single Pole, Group operated
isolator switch complete with manual &
motor driven operating mechanism - 1600A
for 220kV, 1250 A - For 66kV- 1No.
·
ii) 3 Phase, Single Pole, Group operated
maintenance earthing switch complete with
manual operating mechanism - 1 No.
Potential Transformer: 3 Core, Multi ratio,
sine:le phase potential transformer
i) 220KVN 3/ l lOV/-./. 3-l lOV/ v 3-l lOV/ v 3 1 Set (3 Nos.)
ii) 66KV/-../ 3 / l lOV/-../ 3- l lOVN 3-l lOVN 3 1 Set 13 Nos.)
�
5 ��
a.
0)
o h o4•
�*
�
��·*
.. _
5
.....
'
00 0 0 3 5
SI.
Name of the equipment
No
Unit
Supply Rates
in Rs Lakhs
Erection rates
in Rs Lakhs
Nos
Nos
12.58
8. 17
0.45
0.34
Nos
1 0 1 . 18
0.92
Nos
104.03
2.41
Bus Bar- Double bus arrangement:
i) Main Bus - 2500A
ii) Auxiliary bus 1600 A - for 220kV
iii) Auxiliary bus 1250 A - for 66kV
Control cubicle for GIS module, gas
monitoring device, barriers pressure
switches etc as reauired.
7
8
Bus Maintenance earth switch 3 Phase,
Single pole, Group operated maintenance
earthing switch complete with manual
operating mechanism - 1600 Amp
i) 220kV ( 1 for each bus)
ii) 66kV ( 1 for each bus)
66 kV Transformer Module
(For 3 1.5 MVA)
Each module comprising of the following:
SF6 circuit breaker Complete with
operating Mechanism, 1600A, 1 Phase I 3
Phase- 1 No.
Disconnector:
i) 3 Phase, Single Pole, Group operated
isolator switch complete with manual &
motor driven operating mechanism 1250A 2 Nos..
ii) 3 Phase; Single Pole, Group operated
maintenance earthing switch complete with
manual operating mechanism 2 Nos.
9
Current Transformer: 3 Core, Multi ratio,
single phase current transformer 400-200 I
1-1-lA ( 1 set) - 3 Nos.
Bus Bar-Single bus arrangement:
Main Bus - 2000A
Auxiliarv bus - 1250A
Control cubicle for GIS module, gas
monitoring device, .barriers pressure
switches etc .. as reauired.
Cable end unit (Plug in type): 3 Phase,
Single pole, cable termination - 1 Run for
630 sa.mm for each phase - 1 set.
66 kV Line (U.G.Cable) Module
Each modu,le comprising of the following:
SF6 circuit breaker Complete with
operating Mechanism, 1600A, 1 Phase I 3
Phase- 1 No.
Disconne ..
:(\etalMa�
�
�ra
�
..
�...
k>
'5 � �
I °"
o.-,,r'J 0
(1)
Q) � �
t)
' *
�
�
::r
��*�
-
0 0 003 6
Sl.
Name of the equipment
No
Unit
Supply Rates
in Rs Lakhs
Erection rates
in Rs Lakhs
i) 3 Phase, Single Pole, Group operated
isolator switch complete with manual &
motor driven operating mechanism 1250A 2 Nos.
ii) 3 Phase, Single Pole, Group operated
maintenance earthing switch complete with
manual operating mechanism - 2 Nos.
iii) 3 Phase, Single pole, fast acting, fault
make earthing switch complete with group
operated manual & motor driven operating
mechanism - 1 No.
Current Transformer: 3 Core, Multi ratio,
single phase current transformer 1200-800
I 1-1- lA - 1 set 13 Nos.)
Sure:e Arresters - 1 set (3 Nos.)
Cable end unit (Plug in type): 3 Phase,
Single pole, cable termination - 1 Run for
630 I lOOOOsq.mm for each phase - 1 set.
Bus Bar-Single bus arrangement:
Main Bus - 2000A
Auxiliarv bus - 1600A
Control cubicle for GIS module, gas
monitoring device, barriers pressure
switches etc., as required.
10
66 kV Bus Sectionalising module
comprising the following
Disconnector:
3 Phase, Single pole, Group operated
isolator switch complete with manual &
motor driven operating mechanism 2000A 1 Nos.
Bus Bar-Single bus arrangement:
Main Bus - 2000A
Nos
47.96
0.92
Nos
54.49
0.35
Control cubicle for GIS module, gas
monitoring device, barriers pressure
switches etc., as required.
Note: The bus and the equipments may be
with single phase or 3 phase enclosure.
1 1 PT Module
II 66 kV
Each module comprising of the following:
Disconnector:
000 0 3 7
Sl.
Name of the equipment
No
Unit
Supply Rates
in Rs Lakhs
Erection rates
in Rs Lakhs
i) 3 Phase, Single pole, Group operated
isolator switch complete with manual &
motor driven operating mechanism 1250A For 66 kV - 1 No.
ii) 3 Phase, Single Pole, Group operated
maintenance earthing switch complete with
manual operating mechanism - 1 No.
Potential Transformer : 3 Core, Multi ratio,
Single phase potential transformer 66kV
voltage class- lset/ 3Nos
Bus Bar-Single bus arrangement:
Main Bus - 2000A
Auxiliarv Bus 1250A.
Control cubicle for GIS module, gas
monitoring device, barriers, pressure
switches etc .• as required.
22 Rates for supply of Hybrid switchgear:
Hybrid SF6 gas insulated switch gear 40kA
rating suitable for outdoor installation of
1)
modular design with mounting structure Modules for single breaker scheme
Nos
75.00
0.75
Each module comprising or the following:
SF6 circuit breaker Complete with
operating Mechanism, 1600A, 3phase - 1 No.
Disconnector:
i) 3 Phase, three Pole, Group operated
isolator switch complete with manual &
motor driven operating mechanism 1250A 2 Nos. - 1 No. on line side and lNo. On Bus
side
ii) 3 Phase, three Pole, Group operated
maintenance earthing switch complete with
manual/ motor driven operating mechanism
2 Nos. - 1 No. each on line side and 1 No.
on Bus side.
iii) 3 phase, single pole, fast acting, fault
make earthing switch complete with group
operated manual & motor driven operating
mechanism - 1 No. on line side
Note: Combined disconnector and earthing
switch operated by means of a common
driving mechanism is acceptable.
000 0 3 8
Sl.
Name of the equipment
No
Unit
Supply Rates
in Rs Lakhs
Erection rates
in Rs Lakhs
Module
1 10
1.1
Current Transformer: 3 Core, Multi ratio,
single phase Ring type current transformer
1200-800 / 1-1-1-lA 1 set ( 3 Nos.)
oositioned in the bushin2.
SF6 to Air bushing made of Silicon Rubber,
1600A on both line side and Bus bar side
2sets f3 Nos. each l
Local Control cubicle for Hybrid module, gas
monitoring device, pressure switches etc as
reauired.
Hybrid SF6 gas insulated switch gear 40kA
rating suitable for outdoor installation of
2)
modular design of twin Breaker type with
mounting structure - Modules
Each module comprising of the following:
SF6 circuit breaker Complete with
operating Mechanism, 1600A, 3phase -2 No.
Disconnector:
i) 3 Phase, three Pole, Group operated
isolator switch complete with manual &
motor driven operating mechanism 1250A 2 Nos. - 1 No. on line side.
ii) 3 Phase, three Pole, Group operated
maintenance earthing switch complete with
manual/ motor driven operating mechanism
2 Nos. - 1 No. each on line side .
iii) 3 phase, single pole, fast acting, fault
make earthing switch complete with group
operated manual & motor driven operating
mechanism -2 Nos.- 1 No. each on line side
iv) 3 phase,three pole,group operated
isolator switch complete with manual motor
driven operating mechanism 1600A - lNo.
On bus side (Common for both lines)
v) 3 phase, three pole, group operated
maintenance earthing switch complete with
manual/ motor driven operating mechanism
lNo. On Bus side (Common for both lines)
Note: Combined disconnector and earthing
switch operated by means of a common
driving mechanism is acceptable.
000 0 3 1
Sl.
Name of the equipment
No
Unit
Supply Rates
in Rs Lakhs
Erection rates
in Rs Lakhs
Current Transformer: 3 Core, Multi ratio,
single phase Ring type current transformer
1200-800 / 1-1-1-lA - 1 2 set ( 6 Nos.)
positioned in the bushing. 3Nos each on line
side
SF6 to Air bushing made of Silicon Rubber,
1600A on both line side and Bus bar side
3sets (3 Nos. each on line side and 3
Nos.fCommonlon bus side)
Local Control cubicle for Hybrid module, gas
monitoring device, pressure switches etc as
reauired.
OOOO dO
SI No.
Particulars
23
HTLS Conductor with accessories
a)
Conductor and Earth wire
HTLS Conductor
Units
Amount in Rs.
Lakhs
kms
9.25
b)
Accessories for HTLS
1
Dead End Assembly,Single Tongue(W/Terminal)
Each
0.8
2
Thermolign Suspension Assembly (Single)
Each
0. 13
3
Splice (MSC)
Each
0.9
4
Repair Rod
Each
0. 14
5
Vibration dampers
Each
0.07
6
Bus Bar socket
No
0.25
000041
SI.
No.
Particulars
Qty.
Amount in Rs.
24 Hot Line Materials
A Name of Hot Line Tools
1 All angular grounding clamps
lNo
2 All angle players
lNo
3 Epoxy glass bond patching kit
lKg
4 Ball and socket adjuster
lNo
5 Hand line hook
lNo
10250
6650
3500
1880
890
6 Grip all clamp stick
a)
12 Feet
lNo
b)
10 Feet
lNo
c)
8 Feet
lNo
d)
6 Feet
lNo
18 170
17900
16640
14300
7 Epoxy glass ladder
a)
18 Feet
lNo
b)
12 Feet
lNo
126080
95300
8 Two pole strain carrier
a)
12 Feet
2 Poles
b)
10 Feet
2 Poles
c)
8 Feet
2 Poles
9 Cum-a-long, crescent type
lNo
384200
37 1400
361700
48500
10 Insulator cradle
a)
10 Feet
lset
b)
8 Feet
lset
1 1 Static ground tool
lNo
12 Insulated oiler 8 Feet
lNo
13 Pruning saw
lNo
14 Flexible insulated rerich
lNo
15 Rotary blade
lNo
16 Ratchet wrench with universal
lNo
17 Energized insulator tester
lNo
18 C type grounding clamps
lNo
19 Hex socket sets
lset
20 All angular cog wrench
lNo
ft,�en�"
69300
60200
12050
14750
3500
18800
2600
10160
68300
440
14300
29060
Oi.
� �, �'5&:-· )
OJ
::>'.> ., , ..
(!)
�
. ....
�
+;
0 ->: KP:tc'v
�
OOOO d2
SI.
No.
Particulars
Qty.
2 1 Cum-a-long hooks
lNo
22 Extension chain
lNo
23 Link stick of sizes
a) 6 Feet
lNo
b)
lNo
10 Feet
24 Metal stain insulator fork
lNo
25 Pole hangers
lNo
26 Snatch block 5/8 inch
lNo
27 D.E spanners, full set
lset
28 Poly deccron rope
a) 5/8 inch
600Ft
b) Y:a inch
600Ft
Amount in Rs.
3680
1970
10700
14300
6920
440
268 10
8900
44000
30500
29 Poly propelene rope
a) % inch
600Ft
b) Y:ll inch
600Ft
30 Safety helmets
8Nos
3 1 Bionacular with case-500Mts range
lNo
32 Bus bar grounding clamp
lNo
33 Cross arm tool hanger
lNo
34 Flexible rench head
lNo
35 Hydralically operated cutter
lNo
36 Hot stick storage tube
lNo
37 Hot stick manual
lNo
38 Insulated handles with pliers
lNo
39 Safety belts
lNo
40 Nylon Belt strap 7 Feet long
lNo
41 Single pole strain carrier yokes
lNo
42 Single trolley wheel with 2 Y2 inch pole clamp
lNo
43 Conductor end yoke assembly
lNo
44 Structure end yoke assembly
lNo
45 Dead end sockets
lNo
46 Bolted dead end clamp
lNo
47 Pole clamps for two pole strain carrier
lNo
�
�
an
�
a
� -' a.
<.? �
)
-
<b
�
'='
o '•
�
iJ
�
�
1?
�
\;�
k.PJP);·
27800
18800
530
20600
6740
2870
7 100
127700
10700
1700
5570
13670
1 1 150
134900
15300
130400
129500
8900
5300
6550
00 0 0 4 3
SI.
No.
Particulars
Qty.
48 Take up trunions
lNo
49 Tool for W-keys
lNo
Amount in Rs.
6 100
2240
50 Tower saddles
a) 1 %1 inch
lNo
b) 2 inch
lNo
c) 2 Y2 inch
lNo
5 1 Tower and :flat face grounding clamps
lNo
52 Teleheight
lNo
53 Two triple sheave pulley block- Y2 inch
lset
54 Two double sheave pulley block- 3 / 8 inch
lset
12500
16100
19070
4040
10700
31400
37070
55 Universal pole with heads
a) 12 Feet
lNo
b) 10 Feet
lNo
c) 8 Feet
lNo
56 Universal adopter
lNo
57 Hot stick tester
lNo
B
9530
8810
800
102500
Thermovision camera
1 Sub-station with a range of 10- 12mts
2 Transmission lines with range of 20mts
c
9980
Global Positionine: System (GPS)
lNo
670090
lNo
813600
lNo
15000
000044
PART II
SCHEDULE OF RATES FOR LABOUR OF MAJOR WORKS
Amount in Rs.
SI No.
Description
Unit
220
kV
1
A
1 10
kV
66
kV
33
kV
Detailed Surveying on Turn-Key:
i) Reconnoitary Survey-cum-walk
over Survey along with K.P.T.C. Ltd.,
Staff to determine the feasible route
of the line on topo sheet. An
alternate route if available should be
indicated. The route of the line is to
be indicated and got approved by the
competent authority( Rates include
the cost of Toposheet and
Transportation)
al Hillv terrain
bl Plain terrain
KM
KM
1329
1259
668
629
KM
KM
6419
4290
3202
2 137
ii) Detailed Survey, fixing anchor
points and taking levels at 20 Mtrs
intervals, drawing route profile on
Graph paper indicating geographical
features like Nalas, Rivers, Gardens,
P&T Lines, Railway-crossings etc.,
and enroute villages furnishing geoco-ordinates of each location with
survey nos of the lands through
which the line is passing duly
covering the corridor proposed to be
cleared .
al Hillv terrain
bl Plain terrain
Remarks:-In case of detailed survey
of existing line for preparation of
schedules to facilitate placing of
proposals before PTCC, 50% of the
above costs are to be adopted.
0000 4 5
Amount in Rs.
SI No.
Description
Unit
66
kV
220
kV
iii) Fixing marking stones with
approved marks including painting
above the ground level and Yellow
Lettering and marking the direction
of incoming line and out going lines
are to be clearly marked on the top
with red colour. If the distance
between two anchor points is more
than 1 KM, one more directional
stone is to be fixed. So also for the
road crossing, railway crossing and
nala crossing for all on both the
sides.
Per Stone
iv) Burgie details for identification for
Per Anchor
all Anchor towers with existing
Tower
permanent marks like poles,
telephone lines, buildings, etc.,
v) Excavation for soil classification
a) Excavation of soil 1.2 Mtrs. x 1.2
Mtrs. up to a depth of 3 Mtrs. or up
to hard rock is reached which ever is
less (Applicable for soil classification
purpose for 400 kV & 220 kV lines
only)
b) Excavation of soil 1 .2 Mtrs x 1.2
Mtrs. up to depth of 2.5 Mtrs. or up
to hard rock is reached which ever is
less(Applicable to 1 10 kV & 66 kV
lines) The excavation of trial pits
shall be retricted to one pit for every
Km and part there off.
vi) Conductine: soil resistivitv tests
vii) Clearing of bushes, tree branches
of trees crops and shrubs wherever
encountered for detailed survey to
enroute the corridor width of 3 Mtrs
(including viewing for f°lXing anchor
towers etc . \
al Hillv terrain
bl Plain terrain
I
33
kV
319
288
CMT
Rates for different soils encountered as
per actual soil condition applicable for
transmission line (Ref-item 3A )
Per Test
552
Per Km
Per Km
956
637
.
0 0004 :3
Amount in Rs.
SI No.
Description
Unit
I
220
kV
I
1 10
kV
viii) a) Submission of reports in the
form of good binding including the
preparation of sketches for burgie
details for each anchor points,
scheduling of line details, S.R.
values, soil classification reports
tower schedule, abstract of towers
etc., complete.
Per set
194
b) Drawing the route profile on graph
sheet including geographic features
like nala's, rivers, gardens, P&T lines,
railway crossings etc., inclusive of all
stationeries (Normal requirement is 5
Sets)
Per Km
194
ixl Preuaration of Schedules:
a) PTCC Proposal : Containing PTCC
questionaire, topo sheet extracts
with marking of the proposed line,
S.R. Report, tower sketch, station
single line diagram etc.,(30
Conies/Setl
b) Railway Crossing proposal with
drawing are inclusive of graph sheets
and other stationery materials,
labour etc. 1 10 Setsl
I
I
Per set
769
Per
Crossing
769
c) Tree Schedule Containing the
details like name of tree, girth size of
tree, distance from central line of the
alignment, approximate height of the
tree etc., complete
Per
Hectare
552
d) Forest proposals : Inclusive of all
works like fixing of stones at every
20 Mtrs in the centre line and both
ends of the corridor, painting of each
tree after chipping, writing the
numbers on the tree, taking girth size
of all the trees coming in the corridor
at 1 Mtr height from GL, approximate
height of the tree and forest
clearance proposals etc., complete
( 1 0 sets)
Per Km
3590
I
66
kV
33
kV
I
Note: This applies to forest area only
B
Check Survey by using their own
!Eouiument
al Hillv terrain
bl Plain Terrain
Per Km
Per Km
3202
2137
1593
1065
. 000047
Amount in Rs.
SI No.
Description
Unit
220
kV
2
1 10
kV
66
kV
33
kV
A Taking block levels for Sub-stations:
a) Running Peripheral Theodolite
traverse along periphery and
coordinating and heightening of all
comers/turning points, establishing
permanent co-ordinate axis formation
of grids at SOM intervals for northing
and easting with reference to already
established permanent co�ordinate
axis levels at SO M grid intersection
for preparing plot plan of the entire
area with contours. Including existing
structure location.
Hectare
106S
b) Establishing datum level and bench
marks at every lOOM/SOM intervals
both longitudinal and laterally and all
comers/turning points with stone
pillars of size not less than
0.2Mx2Mxl .OM buried on the ground
and exposed top engraved for
painting RL, and co-ordinates of that
Nos.
106S
c) Taking level at SM/ suitable grid
interval in the sub-station area for
l nlottinll block levels. contour man.
Nos.
23
Per Project
10646
, ... ..:. ... +
d) Preparation of CAD drawings,
generating the contours using
appropriate software and submission
of 6 sets of blue prints and one
tracing sheet (original) and one soft
copy etc. Complete.
e) Furnishing cutting and itlling
quantities using appropriate software Per Project
for earth work calculation.
3194
f) Super imposing GA drawings on
contour maps in Co-ordination with
KPTCL engineers and supply of 12
sets of blue print drawings etc.,
comnlete.
8S17
Per Project
00004 8
Amount in Rs.
SI No.
B
Description
Unit
220
kV
1 10
kV
66
kV
33
kV
Geo Technical Investigations:
a) Making 150mm nominal diameter
bore holes at various locations in soil
using suitable approved method of
boring including, cleaning providing
Bore holes at interval and at change
of strata, collections of water
samples, observation such as ground
water etc., Collection of undisturbed
soil samples at every 2.0M/3.0 M
interval and at change of strata,
transporation of all the collected
samples to the laboratory and back
filling of bore holes on completion of
the work, complete as per
specification and instruction of the
6.0M below natural ground level or
refusal strata.
Per Mtr
1593
i) Bulk density and moisture content
Each
637
ii) Sieve analysis
iii) Hydrometer Analysis
iv) Liquid limit and plastic limit
v) Shrinkage limits
vi) Specific gravity
vii) Standard proctor density test
viiil Swell pressure
ix) Free swell index
Each
Each
Each
Each
Each
Each
Each
Each
637
637
637
746
746
746
855
855
x) Uncombined Compressive strength
Each
855
xi) Triaxial shear test
xii) One dimensional consolidation
test
xiii)California bearing ratio
c) Submitting final report in 6 copies
including all field records and
laboratory test results, graphs and
recommendations etc., complete as
1 ner snecifications.
Each
855
Each
855
Each
855
Per Job
12776
b) Conducting various laboratory
tests on soil samples at approved
laboratory including preparation of
soil samples to determinate of soil,
all complete as per specification.
Note: Laboratory identified shall be
approved by KPTCL not below the
rank of EE(Civil)
0 0 00 4 9
Amount in Rs.
SI No.
Description
Unit
220
kV
1 10
kV
66
kV
33
kV
Note: The above rates are inclusive of
mobilization of Plant Equipment &
Materials for , Topographical survey,
block leveling and Geotechnical
investigation works, and
Demobilization. No extra rate is
admisible for mobilization &
Demobilization
3
-
Excavation for station structure:
1) Corresponding rates in KPWD SR as
mentioned against each classification
below shall be adopted.
2) Area weightages applicable for the
respective areas as per Latest KPWD SR
shall be allowed to arrive at final rate.
3) Extra for excavation under water
conditions and/ or foul conditions
including bailing/pumping out,
removing slush add 20% of the rate of
the respective rate on account of slow
progress of work under these
conditions. ( The extra percentage
indicated here shall be as indicated in
the relevant KPWD SR )
Excavation of pits as per
specifications for lattice type of
station structures, Tr. Plinth, control
panels, mounting structures for
breakers, CT's, PT's Isolators, LA's
etc., Excavation of trnches for
control cables, U.G. Cables,
Groundmat etc.,
-
i) Normal Soil
---
A ii) B�C. Soil
iii) Partially Submerged soil
iv) Fullv submerged soil
v) Wet black cotton soil
CMT
CMT
CMT
CMT
CMT
-
Latest
Latest
Latest
Latest
KPWD SR Rate for ordinary soil
KPWD SR Rate for ordinary soil
KPWD SR Rate for ordinary soil
KPWD SR Rate for ordinary soil
vi) Dry fissured/Ordinary rock
CMT
Rate for ordinary rock (without
blasting) of Latest KPWD SR
vii) Latterite soil
CMT
Rate for ordinary rock (without
blasting) of Latest KPWD SR
viii) Hard rock with blasting/Hard
latterite
CMT
Rate for hard rock (with blasting) of
Latest KPWD SR
--
-
Latest KPWD SR Rate for hard soil
Note 1 : For Excavation purposes
measurement shall be as per actuals.
--
Note 2 : For foundation purposes
predominant soil shall be considered.
0 0 0 050
Amount in Rs.
SI No.
Description
Unit
220
kV
,___
,___
t--t--t--t---
-
-
,____
4
-
Excavation IFor Tr. Line Tower}
i) Normal Soil
ii) B.C. Soil
iii) Partially Submere:ed soil
iv) Fully submere:ed soil
B
v) Wet black cotton soil
vi) Drv fissured/Ordinarv rock
viit Latterite soil
viii) Hard rock with blasting/Hard
latterite
Back Filline: :
i) Back filling with excavated earth
available near the tower and
consolidation layer by layer of 150
mm depth with adequate quantity of
water.
ii) Supplying and back filling with
c external hard murrum soil with
proper consolidation including lead
and lift.
Note: This item is applicable only
when Black cotton soil, wet black
cotton soil, dry fissured rock,
ordinary rock, Hard rock are
encountered.
Concreting and curing (For Both
Transmission lines and station
structures}
CMT
CMT
CMT
CMT
CMT
CMT
CMT
1 10
kV
33
kV
66
kV
(Rates as per item3-A + 50% extra)
CMT
+
CMT
Rates as per Latest KPWD SR
extra
CMT
Rates as per Latest KPWD SR + 10%
extra
a) Concreting and curing as per
specifications including the cost of
materials, T&P materials and labour
charges with all lead and lift, for
lattice type station structures, Tr.
Plinth, control panels, mounting
structures for Breakers, CT's PT's
Isolators, LA's, etc.,
10%
1 ) Corresponding rates in Latest KPWD
SR as mentioned against each
classification shall be adopted.
2) For the above basic rate add
applicable area weightage as per Latest
KPWD SR.
-
i) 1:4:8 Concrete (M 7.5)
CMT
Rate under plain concrete for
foundation of Latest KPWD SR.
ii) 1:3:6 Concrete (M- 10)
CMT
Rates under basement of Latest KPWD
SR
iii) 1:2:4 Concrete (M- 1 5)
CMT
Rate under raft foundation of Latest
KPWD SR
,___
-
D
-
. 000051
SI No.
Amount in Rs.
Description
Unit
220
kV
iv) 1 :1 .5:3 Concrete (M-20)
b) Concreting and curing as per
specifications including the cost of
materials, T&P materials and labour
charges with all lead and lift for
Transmission line Towers.
1 10
kV
66
kV
33
kV
CMT
Rate under raft foundation of Latest
KPWD SR
CMT
For arriving at the rates for concrete
items for transmission lines, add 25%
weightage to the basic rates of different
propotions of concrete proposed above.
Kgs
For sub-station works, rate as per
KPWD SR and for Transmission line
works, add 10% extra
MT
249
Note :
a) Extra as indicated in the relevant
KPWD SR may be allowed for
providing concrete in watery
situations including cost of bailing
out water and removing slush.
b) Only machine mixing for
concreting is to be used.
c) Jelly to be used is 20 mm. and
down size for 1 : 1 .5:3, 1 :2:4 & 1 :3:6
concrete and 40mm and down size
for CC 1 :4:8.
Providing and fabricating TMT steel
reinforcement including
straightening cutting, bending
hooking, lapping and I or welding
wherever required placing in position
tieing with binding wire and
E
anchoring to the adjoining members
wherever necessary including laps
and wastages etc., complete as per
design, and specification and
directions (Laps and wastages not to
be measured and paid)
5
Towers
a) Sorting of tower parts made of
fabricated an2'.le iron.
b) setting up of stubs templates and
aligning dismantling and
transportation of templates from one
location to another location
c) Assembling and erection of towers
including tightening of bolts and nuts
including loading, unloading at store
and site (Including the Wt. of stubs).
Per Locn
MT
497
45 1
373
1811
00005 2
Amount in Rs.
Sl No.
Description
Unit
220
kV
1 10
kV
d) Rivetting of tower bolt ends by
heating using dry-Acetylene gas and
hammering to destroy threads so as
to make the tower members theft proof (Bolts at nodal points only to be
selected and rivetted up to hieght of
bottom cross arm, as per the
directions of the field engineer)
Per Bolt
9
e) Welding of bolts and nuts
Per Bolt
9
Per set
1772
Rmtr
33
Nos
Nos
Set ( 3
Nos.)
Nos
34
34
66
kV
33
kV
Note : For tower erections requiring
shutdown 2So/o above S.R. for item
Sc to Se only are to be adopted.
6
Suuulying and fixing A.C. devices :
a) Supplying and fixing G.I. Angle
iron 4Sx4SxS mm ( lmtr length) with
cleats, bolt & nuts as per
specification and fixing above O.S
mtrs length each at inner and outer
surface of the tower to facilitate
runnfna nf' ,_ ,.,._.,1 wf1'�
b) Supplying and fixing barbed wire as
uer specification
Fixing of Boards
a) Fixing Danger Board
b ) Fixing Number Plate
__
7
c) Fixing Phase Plate
8
d) Fixing Circuit plate
Stringing of Conductor without
allowing the conductor to touch the
ground and without damaging the
conductor.
103
34
a) Paving out conductor from anchor
to anchor normally spaced at s spans
with 4 tangent towers in between,
including providing stays at each
anchor points and jointing of
conductors, hoisting and fixing of
insulator string, armour rods,
vibration dampers, including the cost
of T&P materials like comealong, wire
ropes, pulley, rollers, suspension
clamps, compression jointing
machines with bits, drum stands,
manila ropes, truckker and jeep etc.,
(Rate for 1 route KM of single
conductor)
000 0 5 3
SI No.
Amount in Rs.
Description
i) For hilly terrian
Unit
KM
220
kV
1 10
kV
17547
8774
66
kV
I
33
kV
7972 with coyote
ACSR
r--
7972 with Rabbit
ACSR on Towers
r--
2191 with Rabbit
ACSR on RCC
Poles
ii) For Plain terrian
KM
13498
6264
5844 with coyote
ACSR
r--
2921 with Rabbit
ACSR on Towers
r--
1756 with Rabbit
ACSR on RCC
Poles
b) I) Stringing of ground conductor as
above
i) For hilly terrian
ii) For plain terrian
KM
KM
5852
4383
4383
3505
3901
2922
Note: Conductors normally used are:
i) 220kV - Drake and AAAC Moose
ii) 1 lOkV - Lynx and Drake
iii) 66 kV- Coyote and Drake
II) For shut down works 50% more
than the above rates of the work
(This is applicable to shut down of
33kV and above lines only. l lkV &
L.T. lines shut down not included)
50% more above the rates specified for
normal works is admissible for shut
down works of 33kV and above lines,
CTs, PTs, LAs only. This is not
applicable for l lkV & L.T line shut
down works.
000 0 5 4
SI No.
Amount in Rs.
Description
Unit
220
kV
III) For National Highway crossing
railway crossing and State highway
crossine:
IV) River crossing exceeding more
than 20% of the normal span.
This is applicable to stringing the
lines running parallel to a charged
circuit also.
9
I
I
uo
kV
I
66
kV
15%
I
33
kV
corresponding normal span stringing
rate + 30 % extra
V) Rates for 33 kV Stringing are
separately indicated under SR for 33
kV works.(Crossing charges should
not be allowed when shut down
char2'es are admittedl
VI)Restoration of power supply due to
dislocation of existing transmission
line towers
These Rates are applicable only when
total Length of the entire Line is less
than 3 suans.
75%
A) Stringing of conductors in special
conditions where normal 5 spans
between anchor to anchor are not
encountered, whereas anchors are
provided at single/two/three spans
with average span intervals of
267 /320 Mtrs, (rate for spans of
single conductor)
U For hillv terrian
a) Anchoring single span upto 320
mtrs.
1 Span
9768
4873
4173 with coyote
ACSR
2044 with Rabbit
ACSR
b) Anchoring 2 span interval upto 640
mtrs with 1 tangent tower only
2 Spans
12 177
6077
5175 with coyote
ACSR
2471 with Rabbit
ACSR
c) Anchoring 3 span interval up to
960 mtrs with two tangent towers
only
3 Spans
14649
7320
6069 with Coyote
ACSR
000055
Amount in Rs.
SI No.
Description
Unit
220
kV
1 10
kV
66
kV
33
kV
2921 with Rabbit
ACSR
iii For plain terrian
a) Anchoring single span up to 320
Mtrs
1 Span
75 15
3404
3132 with coyote
ACSR
1508 with Rabbit
ACSR
b) Anchoring 2 span interval upto 640
Mtrs with 1 tangent tower only
2 Spans
9388
4367
40 10 with coyote
ACSR
1850 with Rabbit
ACSR
c) Anchoring 3 span interval upto 960
Mtrs with two tangent towers only
3 Spans
1 1260
5261
4491.63 with
Coyote ACSR
2169 with Rabbit
ACSR
B) Stringing of ground conductor as
above
il for hillv terrian
a) Anchoring single span upto 320
mtrs
1 Span
3233
2425
2 106
2 Spans
4049
3046
2510
3 Spans
4873
3660
2984
1 Span
2448
1958
1585
b) Anchoring 2 span interval upto 640
Mtrs with 1 tangent tower only
2 Spans
3062
2425
1927
c) Anchoring 3 span interval upto 960
Mtrs with two tangent towers only
3 Spans
3684
2937
2269
b) Anchoring 2 span interval upto 640
mtrs with 1 tangent tower only
c) Anchoring 3 Span interval upto
960 mtrs with two tangent towers
onlv
iii For plain terrian
a) Anchoring single span upto 320
Mtrs
000056
SI No.
Amount in Rs.
Description
Unit
220
kV
1 10
kV
66
kV
33
kV
Note: 1) Conductors normally used
are
i) 220kV - Drake and AAAC Moose
ii) l lOkV - Lynx and Drake
iiil 66 kV- Covote and Drake
2) For Shut down works 50% more
above the normal rates of respective
works (This is applicable to shut
down of 33kV and above lines only.
l lkV & LT line shut down works not
included).
Rates for Short span stringing in
Normal length of the line of more
II
than 3 spans comprising of short
snans
A) Stringing of conductors in special
conditions where normal 5 spans
between anchor to anchor are not
encountered, where as anchors are
provided at single/two/three spans
with average span intervals of
275/320 Mtrs, (rate for spans of
single conductor)
U For hillv terrian
a) Anchoring single span upto 320
Mtrs
1 Span
1469
730
62 1 with coyote
ACSR
304 with Rabbit
ACSR
b) Anchoring 2 span interval upto 640
Mtrs with 1 tangent tower only
2 Spans
2432
1212
1033 with Coyote
ACSR
498 with Rabbit
ACSR
c) Anchoring 3 Span interval up to
960 Mtrs with two tangent towers
only
3 Spans
3660
1834
1515 with Coyote
ACSR
73 1 with Rabbit
ACSR
iil For Plain terrian
00 0 0 5 7
SI No.
Amount in Rs.
Description
a) Anchoring single span upto 320
Mtrs
Unit
1 Span
220
kV
1 10
kV
1 127
513
66
kV
I
33
kV
467 with Coyote
ACSR
226 with Rabbit
ACSR
b) Anchoring 2 span interval upto 640
Mtrs with 1 tangent tower only
2 Spans
1881
870
762 with Coyote
ACSR
373 with Rabbit
ACSR
c) Anchoring 3 Span interval upto
960 Mtrs with two tangent towers
only
3 Spans
28 13
1313
1 127 with Coyote
ACSR
567 with Rabbit
ACSR
B) Stringing of ground conductor as
above
ii for hillv terrian
a) Anchoring Single span upto 320
Mtrs
b) Anchoring 2 Span interval upto
640 Mtrs with 1 tane:ent tower onlv
c) Anchoring 3 span interval upto
960 mtrs with two tangent towers
onlv
ii) For Plain terrian
a) Anchoring single span upto 320
Mtrs
10
1 Span
482
365
319
2 Spans
808
606
505
3 Spans
1220
91 7
746
1 Span
365
295
241
b) Anchoring 2 span interval upto 640
Mtrs with 1 tangent tower only
2 Spans
614
614
389
c) Anchoring 3 span interval upto 960
Mtrs with two tangent towers only
3 Spans
1041
738
567
A) Clearing of bushes, branches of
tree & Crops for erection of tower &
Stringing of line for full corridor
width.
al In thin June:le
bl In thick Junl?le
Per Km
Per Km
2339
3513
000053
SI No.
Amount in Rs.
Description
Unit
66
kV
220
kV
c) Removing grass/vegitation,bushes
in station yard/ premises including
disposal of the same.
B) a) Cutting of trees of different
girths including cutting of trunks,
branches and removal of stumps
stacking of serviceable materials
earth filling in the depressions/pit,
labour charges complete as per
1::necifications
b) Transportation of wood to the
desired destination as per KPTCL
directions
c) Clearing and grubbing land
including uprooting rank vegetation,
grass, bush, shrubs, saplings and
trees of girth up to 300mm by
manual means in area of light jungle,
removal of stumps, disposal of
unserviceable materials, stacking of
serviceable materials, labour charges
complete as per specifications.
11
I
Sq. Mtr
8
Nos
As per applicable KPWD SR
Cum
Rate as per forest SR
Sqm
As per applicable KPWD SR
33
kV
Material + Labour
Grounding of towers/Equipments
a) Grounding of towers including cost
of 40mm dia 2.5 mm thick, class 'C'
G.I. Pipe of 3 Mtrs length as per
specifications, with 50X6 mm GI
Flats 3 Mtr long, salt charcoal,
including excavation charges.
Set
2246+62 1
b) Grounding of towers/ Equipments
excluding the cost of G.I. Pipe/C.I.
Pipe as per specifications with 50X6
mm G.I. Flat 3 Mtr Long (to be
supplied departmentally). But salt &
Charcoal to be supplied by
contractor. The rates include
excavation charges.
Set
589+621
c) Grounding of equipments by
providing cast iron pipe of lOOmm ID
13mm thickness, 2. 75 Mtrs long with
2 part clamp out of G.1.Flat 50X6mm
continuously welded alround the pipe
using cast iron welding electrodes as
per drawing including the cost of
excavation (All materials to be
supplied by the contractor)
Set
5500+ 1500
00005 9
Amount in Rs.
Sl No.
12
13
Description
Note : All the leads from earthmat &
equipment should be connected to
earth electrode through the GI Flat
50 x 6 mm of suitable length and
welded as ner snecifications.
Supplying and fixing of counter poise
earthing with G.I. Stranded wire
where hard rock is encountered as
per specifications. (including
excavation char2esl.
Station Structures
a) Erection, assembly and alignment
of Station structure as per the
directions of site Engineer.
14
b) Erection, alignment & assembly of
fabricated steel lattice structure,
pedestal structures & Mounting
structures, for G.O.S., CTs, PTs LAs
etc..
Erection of Transformers
a) Moving the Transformer to the
plinth. Maximum allowable distance
is 50 Mtrs. (More than 50 Mtrs.
approval of the D(T) has to be
obtainedI
b) i) Assembly of Transformer parts
like bushings, radiators, filling oil
into Tr. etc., for the total wt. of the
Tr.
ii) Filling oil to the power Tr.
Conservator and radiator (for
maintenance purpose onlvl
For 5 MVA to 20MVA Tr.
For 50 MVA & above with vaccum
iii) Filtration of oil using filter set of
the contractor, to bring the
insulation value to I.E.
Soecifications.
iv) Filtering Oil as above but with the
filter set supplied by the board.
c) Wiring of Transformer marshalling
box, bucholtz relay, fbdng
Thermometer, OLTC upto control
panel and assisting in testing and
commissioning by RT/MT/Firm
en'1'ineers
ii 5MVA to 6.3/8 MVA Tr.
iii lOMVA to 20MVA Tr.
iii) Above 20 MVA Tr.
a
;:I�
(!)
<Zi
:::>
0
( \ 041
0 * ";;
�
&\
�·I
'1
� I;
)
:>..-.. � /
Unit
220
kV
I
1 10
kV
I
66
kV
Per Loe
1 599+ 1430
MT
2 106
MT
1593
Per
MT/Mtr
34
MT
762
Litre
Litre
2
2
Litre
3
Litre
2
L/S
L/S
L/S
35 13
7025
1 17 1 1
I
33
kV
000060
Sl No.
Description
Amount in Rs.
Unit
220
kV
15
16
17
Fabrication of Transformer railing
and embedding in Transformer
plinth. (Rails to be supplied by the
Corooration'
Fixine: of H. T. fuse units & wiring
18
JI. R�li'R -
699
Per Set
816
100/
150
MVA
66
kV
33
kV
12.5/2
0/31.5 8 / 10
MVA
MVA
5/6.3
MVA
1 1835
47340
9862
6575
39448 26300
59 17
23668
Per Set
124 1 1
9932
7445
4966
set
2437
1989
1492
995
set
7671
59 17
59 17
591 7
set
30684
23668 23668
23668
Set
( 3 Nos.)
6209
Lump Sum
for Each
� , __
Erection of Breakers
a) Breaker Erection, assembly,
alignment & interpole wiring of
breakers with its connected
equipments including movement
from the point of unloading to the
noint of erection.
b) Assisting in Testing and
Commissionine:
c) Testing & Commissioning:
Wiring:Identification, ferruling,
crimping and termination of wires in
Breaker & Wiring up to control
1 nanel/Relav oanels.
Testing: Test for insulation level, gas
leakage, Testing for travel time, Trip
and close timings. Local Trip close
test, Remote trip and close test,
Tripping through relays, operation of
interlocks etc.,
19
L/S
Testing & Commissioning of Power
Transformers
a. Inspection of wires and Ferrules.
Inspection of wiring of Protective
Devices, Cooling fans, Oil flow
Pumns. OLTC. RTCC
b.Testing:
1 . Ratio Test
2. SC test
3. Excitation test
4. Magnetic Balance test
5. Vector group test
6. Induced High voltage test
7. OLTC operation
8. Protective Devices operation
Checks
9. Stability Checks: For Differential
1 10
kV
Erection of CTs and PTs
a) Erection of CTs and PTs and wiring
including movement from the point
of unloading to the point of erection.
4966
2479
1243
00006 1
SI No.
Amount in Rs.
Description
b) Assisting'in Testing and
Commissionine:
c) Testing & Commissioning of
Current transformers:
Wiring:Inspection of wiring,Ferruling,
Crimping of lugs, Connections up to
marshalling box & Control panel.
Testing and commissioning of CTs:
Insulation, Polarity, Ratio,
Excitation.
d) Testing & Commissioning of
Potential transformers:
Wiring:Inspection of wiring,Ferruling,
Crimping of lugs, Connections up to
marshalling box & Control panel.
20
21
Testing and commissioning of PTs:
Insulation, Polarity, Ratio,
Excitation.
Erection, Testing & Commissioning
of NCTs
a) Erection of NCTs including
movement from the point of
unloading to the point of erection
with e:roundine: connections
b) Assisting in Testing and
Commissionine:
Erection of Isolators
a) Assembly, Errection alignment and
wiring including movement from the
point of unloading to the point of
erection.
i) Upright
ii) under hung
b) Assisting in Testing and
Commissioning
U Upright
ii) under hung
Unit
220
kV
1 10
kV
66
kV
33
kV
f 3 Nos.)
746
622
497
373
Set
( 3 Nos.)
3945
1972
1972
1972
Set
( 3 Nos.)
15780
7888
7888
7888
Set
( 3 Nos.)
1972
1972
1972
1972
Set
( 3 Nos.)
7888
7888
7888
7888
Set
1989
1578
746
365
Set
85
85
85
47
Set
Set
6209
7453
4966
6209
2487
3730
746
Set
Set
622
746
497
622
249
373
78
Set
Note: 1) Assisting in testing and
commissioning for item no. 17 to 19
means contractors should provide
labourers for testing and
commissioning by RT /MT /Firm
engineers.
2) Testing & Commissioning in item
17 & 20 means the testing will be
carried out by the firms themself
using their own testing equipments &
staff in presence of the MRT staff
who will witness the tests.
0 0 0 0'6 2
Amount in Rs.
Sl No.
22
23
24
25
Description
Erection of Li2htninl! Arrestors
Erection of Lightning arrestors and
wiring including movement from the
point of unloading to the point of
erection
Fixine: of Solid Core insulator
Test & Commissioning: Capacitor
Bank with reactors
Control Cables and U.G. Cables
a) Formation of Cable Duct
i) Burnt brick/size stone/RCC Cable
duct including form box, back f°llling
the sides, removing the excess
escavated soil, duct covering with
RCC slabs.
ii) Supplying 300 mm dia 1 . 5'.' to 2"
thick RCC Hume pipes including
loading unloading, and transportation
charges and laying at required level
and gradient as per the direction of
field engineer
Unit
220
kV
1 10
kV
66
kV
33
kV
Set
1243
746
373
187
Per Stack
249
194
148
62
15325
15325
15325
Each
Cmt
As per Latest KPWD electrical SR
applicable to respective areas.
As per Latest KPWD electrical SR
applicable to respective areas.
b) Providing, laying and jointing PVC
pipes conforming to IS 4085-1960, &
7634- 1975, and approved makes with
necessary specials such as collars,
bends, Elbows, Tee, nipples, plugs
with cuts and threads using jointing
ring with solutions, wherever
necessary as per the directions of the
field engineer including all lead and
lift.
As per Latest KPWD electrical SR
applicable to respective areas.
25 mm dia (outer) 2mm to 2.5mm
thick
Mtr
As per Latest KPWD electrical SR
applicable to respective areas.
32 mm dia (outer) 2mm to 2.Smm
thick
Mtr
As per Latest KPWD electrical SR
applicable to respective areas.
63 mm dia (outer) 2mm to 2 .5mm
thick
Mtr
As per Latest KPWD electrical SR
applicable to respective areas.
r, r"' ''
0 0 C· ' ' b
IV
\
\,,/
SI No.
Amount in Rs.
Description
Unit
220
kV
1 10
kV
66
kV
33
kV
75 mm dia (outer) 2mm to 2.5mm
thick
Mtr
As per Latest KPWD electrical SR
applicable to respective areas.
90 mm dia (outer) 2mm to 2.5mm
thick
Mtr
As per Latest KPWD electrical SR
applicable to respective areas.
1 10 mm dia (outer) 2mm to 2.5mm
thick
Mtr
As per Latest KPWD electrical SR
applicable to respective areas.
140 mm dia (outer) 2mm to 2.5mm
thick
Mtr
As per Latest KPWD electrical SR
applicable to respective areas.
160 mm dia (outer) 2mm to 2.5mm
thick
Mtr
As per Latest KPWD electrical SR
applicable to respective areas.
Rmtr
225+156
Rmtr
165+ 105
Rmtr
7
Rmtr
39
Rmtr
39
Rmtr
39
Rmtr
39
Nos
1725
Nos
2246
c) Supplying & Laying cable trays
including welding fixing of supports
26
i) Cable tray of 600mm width
(Suitable for cable ducts of A, B & C
tvoel
ii) Cable tray of 300mm width
(Suitable for cable duct of D tvoel
d) Laying of control cables from
eauipments to control oanels.
e) Laying of 1 1 kV cables in existing
trench/G.I. Pipe/Stoneware
pipe/RCC Hume pipe using wooden I
aluminium rollers as directed by
KPTCL staff.
i) Cables of Sizes 3Cx95 to 3Cx150
sq mm
ii) Cables of sizes 3Cx185 to
3Cx240samm
iii)· Cables of sizes 3Cx300 to 3Cx400
samm
iv) Cables of sizes 1Cx630 to
lCxlOOO sqmm
f) Fixing of pot heads for HT cable
onlv
i) Epoxy type
ii) Heat Shrinkable/Cold
Shrinkable /Pushon
Control Panels
00 0 0 6 :1
Amount in Rs.
SI No.
Description
a) Erection of control panel, auxilary
panel, carrier cabinet etc., alignment
and f"'ixing properly to foundation
base including movement from the
point of unloading to the point of
erection.
b) Wiring & assisting in testing and
commissionine: of nanel.
c) Test & Commissioning:
i) C& R Panels Wirine: & Testine::
Wiring of C&R panels:
Identification, ferruling, crimping,
termination of wires in C&R panels.
Testing of C&R panels: Testing for
insulation level Testing of relays,
control operations for closing
tripping etc., interlock. Alarm
Annunciation & Indication Checks.
ii) Sychronising Trolley/Panel:
Wiring, Testing, Calibration of meters
& Testine: for ooeration
iii) Bus Bar Protection Panel wiring &
testine::
Unit
Per Panel
1 10
kV
66
kV
33
kV
3108
3108
2487
2487
59 17
59 17
23668 23668
23668
3886
Per Panel
Per Panel
7835
Per Panel
31340
Each
1 1 536
59 17
Each
Wiring:
Identification, ferruling, crimping,
termination of wires in Bus Bar
protection panel.
Rs.2307 upto 3 Bays & Rs.986 for each
additional Bay.
Rs.9229 upto 3 Bays & Rs.3944 for
each additional Bay.
Testing: 1 .Testing of relays. 2.
Stability test.
27
220
kV
1 1 kV Switche:ear
a) Erection, alignment and fixing to
the foundation, indoorI outdoor 1 lkV
switchgear Panel/unit including
movement from the point of
unloading to the point of erection.
i) 1 lkV Indoor/ out door switche:ear
ii) l lkV Kiosk
b) Wiring & assisting in testing &
Commissionine:
fl��,
��f�
j
\ �'
\-:;!
�
� \�)'�
�u
oho
-�
'" · i
.J:.'
"1'..':'
t
Per uanel
Per Panel
1492
1243
000 0 6 5
Amount in Rs.
Sl No.
Description
i) 1 1 kV indoorI outdoor switchgear
Unit
220
kV
1 10
kV
66
kV
33
kV
Per Panel
497
ii) 1 lkV Kiosk
c) Testing & Commissioning:
Wiring: Identification of wires,
Ferruling Crimping & Termination of
wires for annunciation, etc.,
Testing of Relays, CTs, PTs, &
Breaker for oneration.
i) For indoorI outdoor panel
comnrisinll of 21+SF+ lBC+ 1AP3
Per Panel
497
Per set
65503
ii) For single l lkV panel indoor type
Each
13098
Each
6549
Each
13098
Each
10009
Main bus/cross bus (all the three
phases in a segment) of using
Falcon/Drake/Lynx/Coyotesingle/double conductors with fixing
of insulator spacers, levelling of
string conductors to the required
height above the equipment,
including providing jumps to
interconnect different segments of
the main bus.(Spacers to be used only
for Double Conductor)
Per Bay
Main/Cross bus with spacers (Spacers
to be utilised only for Double
Conductor) using i) Quad Moose ACSR
ii) Falcon single conductor- 6901/- iii)
Falcon double conductor- 10347 /- iv)
Single drake conductor- 5519/- v)
Double drake conductor - 8282 /- vi)
Single Lynx conductor -459 1/- vii)
Single Coyote-conductor- 4591 /-
Groundmat
a) Laying of M.S. Flats, welding,
applying ACB paint to welded portion
and covering with sodium bentonite
clav
Rmtr
25
iii) For additional 1 lkV panel (indoor
tvoe)
iv) For single l lkV panel outdoor
tvoe/Kiosk
v) For each additional l l kV panel out
door tvoe/Kiosk
Note:Assisting in testing &
Commissioning for item 22,24& 23
means contractors should provide
labourers for wiring & Commissioning
by RT/MT/Firm Engineers.
28
29
Busbar Formation
00( .
. .
'
'-' ·-· -
0 00065
Amount in Rs.
Sl No.
Description
Unit
220
kV
b) (i) Supplying and laying of MS
flats of vartious sizes, welding and
applying ACB paint to welded portion
and covering with sodium bentonite
clay, as per the drawing/standard
specifications and consolidation.
o
I
kV
66
kV
Rmtr
50x6-273
50x8-291
75xl2-566
75x6-505
75x8-535
Rmtr
50x6- 135
50x8-152
75xl2-429
75x6-367
75x8-395
c) Grounding of equipment with
50x6mm G.I. Flat and connecting
Equipment to the earthmat/ground
pit. Each point of earthing with all
formation works like bending,
twisting, drilling of holes and
connecting by welding (inclusive of
all T&P and consumables) to the
earthmat/ ground pit/ point of earth
connection, all the materials supplied
by the contractor
Rmtr
50x6-226
50x8-253
75xl2-618
75x6-541
75x8-571
d) Providing 25mm dia M.S.rod 1 .05
Mtr. Long earthmat spikes including
heating, bending top 50mm over lap
flattening and making spike edge at
one end driving into the earth below
the ground level and welding the rod
with ground mat flat.
Each
194
Each
645
Rmtr
513
ii) Same as above but without sodium
bentonite clay
30
I
u
e) Supplying & Providing 450 mm dia
450 mm height 1 .5" to 2" thick hume
pipe collar (non pressure type) for
earth pits including all lead and lifts
etc ..
Providine: Deep Bore earthine:
I
"Sinking bore of 1 50mm clear dia
using fast rig including fixing of
40mm dia MS rod, including jointing
the pipes as per KPTCL standard and
providing sodium bentonite
treatment in the annular space,
including transportation of rig and
other supporting vehicles etc.,
complete, as per the directions of
engineer in charge, including cost of
MS rod & sodium bentonite".
a) Drilline: 1 50mm dia bore
0 00 0 6 7
33
kV
Amount in Rs.
Sl No.
Description
Unit
220
kV
31
32
bl 40 mm dia MS rod
c) Bentonite Clav
d) Cost of GI flat for joining two rods
by welding to obtain continuous
lenirth
Site surfacine:
Rmtr
Ke:s
66
kV
I
33
kV
Per joint
427
a) Spreading and forming stone dust
to require level as per specification
including cost of all
materials,labour,lead etc. complete
Cmtr.
260
b) Supplying and spreading lOOmm
thick with 20/25mm jelly with all
lead and lifts.
i) 20/25 mm Jelly
Note : Only 20/25mm jelly shall be
used.
Station Yard Lightning
Cmtr.
1 1 12
Per set
As per Latest KPWD electrical SR
applicable to respective areas.
b) Supplying and fixing of Sodium
Vapour lamp fittings of 250 watts.
Per fitting
As per Latest KPWD electrical SR
applicable to respective areas.
c) Supplying and laying of 1 . lkV, 6
Sqmm PVC cable or any other
specified size, testing and
commis�ioning of yard lights.
Rmtr
As per Latest KPWD electrical SR
applicable to respective areas.
a) Supplying and erection of
fabricated supporting structures
including foundation.
d) Erection of RCC poles with
stringing of O.H. conductor/Laying
of cable for yard lights.
33
-1
l
1 10
kV
404
11
Rates for different items as per ESCOM
SR to be applied.
Material + Labour
Painting of structures
a) Supplying and painting of two
coats of good quality Red Oxide
primer after cleaning and scrapping
the surface.
Sqmtr
15+32=42
b) As above with 2 coats of good
quality Aluminium paint after2 coats
of good quality Red Oxide primer.
Sqmtr
35+48=76
c) Supplying and painting two coats
of aluminium paint after cleaning and
scraping the surface wilthout
applying Red Oxide primer
Sqmtr
15+26=37
000068
Amount in Rs.
SI No.
Description
Unit
220
kV
34
I
I
1 10
kV
66
kV
d) As per (b) but with synthetic
enamel naint
Sqmtr
e) Supplying and painting two coats
of Synthetic enamel paint after
cleaning and scraping the surface
without aplying red oxide primer.
Sqmtr
22+23=42
Set
Set
Set
16141
6209
2479
Set
Set
Set
995
995
995
35+55=81
I
33
kV
Battery Set and charger
a) Installing, assembling, filling of
acid, wiring, assisting, test-charging
and discharging Battery set.
U 220 Volts
iii 1 10 Volts
iii) 48/24 Volts
b) Erection of Battery Charger and
wirina:
i) 220 Volts
ii) 1 10 Volts
iii) 48/24 Volts
c) Testing & Commissioning of
Battery Charger:
Wiring: Identification, Ferruling,
Crimping & connecting
i) AC Supply cable upto 2 sources
ii) Load cables, connection at charger
1 ..,,,,. unto 1 0 ln<>ll nninh•
6509
4261
4261
4261
Testing:
i) AC supply voltage phase Sequence.
ii) Testing of Output DC Voltages in
Boost/ Float/ Trickle/ Variations as
per the orderI requirement.
iii) Testing for repel factor.
Commissioning: i) Fixing of Boost
Voltage level
ii) Fixing of Float Voltage level
iii) Fixing of Trickle Voltage level
iv) Testing of alarm, indication and
load ckts, Auto/Manual change overs
etc.
v) Full load test in Boost & Trickle
·--
a) 220 V DC:
bl l lOV DC:
Per set
Per set
26037
17042
17042
17042
. 0000 6 7
Amount in Rs.
Sl No.
Description
Unit
220
kV
35
PLCC Equinments
a) Erection of mounting structures
for counline: capacitors
b) Erection of Coupling
capacitors/wave traps/LMU.
c) Wiring , testing and commissioning
37
39
33
kV
As per Latest KPWD SR applicable to
respective areas
Set
3886
Set
7771
Set
777
3886
3886
3886
6209
2961
1461
668
668
435
Yard Levelling
Yard Levelling and filling up of soil
and consolidation.
38
66
kV
Fencine: :
Colony and Station yard Boundary
fencing including erection of
supports
a) Security fencing using 8G
chainlink/ 50mm Mesh
b) Barbed wire fencing
36
1 10
kV
Watch and Ward
Emoluments for watch and ward
including pay and DA for 8 hours
dutv
Transportation
Cmt
As per Latest KPWD SR applicable to
respective areas
Per Shift
174
Transportation of Transformer, CT's,
A PT's, Breakers, C&R Panels, 1 lkV
Switchgears and EHT LA's only.
1 . Usine: 10 MT Lorry
Upto 250kms
km
Rs.30.00
greater than 250kms
km
Rs.25.00
km
km
Rs.50.00
Rs.45.00
km
km
Rs.65.00
Rs.60.00
km
km
Rs. 100.00
Rs.85.00
2. Usine: 10 MT Truck & Trailor
Unto 250kms
I greater than 250kms
3. Using 1 1 to 20 MT Truck & Trailor.
Upto 250kms
greater than 250kms
4. Using 21 MT to 40 MT Truck &
Trailor.
iU 5 1 to 100 KMs
iiil 101 to 150 KMs
iv) Bevond 150 KMs
Upto 250kms
greater than 250kms
5. Using 41 MT to 80 MT Truck &
Trailor.
, 0 0 0 0 7 .:
-
Sl No.
Description
Upto 250kms
rereater than 250kms
6. Using 81 MT to 120 MT Truck &
Trailor.
iiU 101 to 150 KMs
iv) Beyond 150 KMs
Upto 250kms
a:reater than 250kms
Note:l)The rates are for up and down
journey.
2)Detention charges are Rs. 4500.00
per day for vehicles upto 40MT
trailor and Rs.12500.00 for vehicles
l arll'!AtPr +h .. ... 40MT ..-..., n--
Amount in Rs.
Unit
km
km
220
kV
Rs.450.00
Rs.420.00
km
km
Rs. 1000.00
Rs.800.00
1 10
kV
66
kV
33
kV
0 0 0 0 7.1
B
Sl.
N
0
Transportation by Head Load wherever there is no accessability for transportation by
vehicle for transmission line works only.
Total Distance
Steel,
Cement, Per
Ton in Rs.
3
4
5
6
Beyond 50 Mtrs and upto
100 Mtrs
Beyond 100 Mtrs and upto
150 Mtrs
Beyond 1 50 Mtrs and upto
200 Mtrs
Beyond 200 Mtrs and upto
250 Mtrs
Beyond 250 Mtrs and upto
300 Mtrs
RCC Pole
300 Kg WL
Rate per
pole in Rs.
included in the item Rate
1 Up to 50 Mtrs initial lead
2
Rough, size,
Earth, Gravel,
cut Latterite
Sand, Lime &
Stones,
other Str.Mat.
Concrete
Rate per Cmt in
Blocks Rate per
Rs.
Cmt in RS
14
18
23
283
23
29
36
407
32
40
50
45 1
39
49
61
5 19
49
61
77
5 19
' 0 0 00 7 �
I
SI.
No.
Discription
Unit
220
KV
I
Amount in Rs.
1 10
66
KV
KV
I
I
33
KV
d) Using light vehicle including fuel, oil, lubricants and
crew subject to a minimum of 100 Kms per day in
Per Day Prevailing Board approved Rates
case of break down/ subject to prior approval of
CEE(Transmission Zone).
40
Loadin2 and Unloading
a) Loading of Power Trs, CT's. PT's Breakers, C&R
Panels, 1 lKV Switchgears, wavetrap, coupling
capacitors, HT UG Cables, Insulators, ACSR
Conductor, Ground Conductors, etc.,
MT
1 3 13
MT
1 3 13
MT
233
MT
233
A) Earth work in surface excavation in the following
soil/Rock and removing the excavated
types of
stuff with all leads and lifts, disposed earth leveled ,
excavated surface leveled & neatly dressed etc
complete as per specifications.
a) Ordinary soil
b) Hard soil
c) Ordinary rock/soft rock/laterite soil
d) Hard rock
Cmt
For sub-station works, rate as
per KPWD SR and for
Transmission line works, add
25% extra
B) i) Construction of revetment/retaining wall with
size stone masonry for foundation/basement in CM
1:6
Cmt
B ii) Construction of revetment/retaining wall with
rubble stone masonry for foundation/basement in CM
1:6
Cmt
B iii) Providing and laying pitching on slopes laid over
prepared filter media including stone/boulder apron
laid dry in front of toe of embankment complete as
per drawing and technical specifications
Cmt
b) Unloading of power Transformers, CT's PT's
Breakers, C&R Panels, 1 1 KV Switchgears, Wavetrap,
coupling capacitors, HT UG Cables, Insulators, ACSR
conductor, Ground conductors, etc.,
c) Loading of other materials like structural steel,
buildinl! materials etc
d) Unloading of other materials like structural steel,
buildinl!'. materials etc.,
Benchinl!'., Revetment and Pitchinl!'.
.•
41
42
Labour for 66/33KV lines using 9/9.5 Mtrs Long RCC
Poles
a) Erection of 9 /9.5 Mtrs RCC Poles 300 Kg working
load, in the excavated pit as per the approved drawing
specification (excluding the cost of excavation,
backfilling and concreting)
Note: The rates of excavation, Backfilling and
concreting are to be adopted as noted in SL nos 3 and
4 resuectivelv.
No.
For sub-station works, rate as
per KPWD SR and for
Transmission line works, add
25% extra
497
I
0 0 00 7 3
Sl.
No.
Discription
b) Erection of DP structure excluding cost of erection
of RCC poles. Including fixing of braces insulators
etc., as per the approved drawings and specifications
(excluding the cost of excavation, backfilling and
concreting).
Note: The rates of excavation, Backfilling and
concreting are to be adopted as noted in SL nos 3 and
4 respectively.
c) Fixing of V·Shape cross arms, single top supports
and insulators.
di Fixine: of spiral earth electrodes
el Road/P&T Guardine:
f) Stringing Rabbit conductor, fixing disc insulator to
cross arms etc.,
ii For hilly terrain
iii For plain terrain
g) Fixing of guy sets in the excavated pits using 7 /9 or
7/ 10 SWG guy wire / turn buckle, guy rod break
insulators, as per the approved drawings and
specifications (excluding the cost of excavation,
backfillinl? and concretinl?\
Unit
Set
220
KV
Amount in Rs.
66
1 10
KV
KV
33
KV
894
Set
101
62
Set
Set
78
668
78
622
KM
KM
1803
1290
1 741
1290
Nos.
149
149
RM tr
39
39
Note : The rates of excavation, backfilling and
concreting are to be adopted as noted in SL nos 2,3
and 4.
43
h) supplying and fixing of AC devices as per
specification
Dismantling
Same rate as that of erection of
Power Transformer
i) Dismantling of Power Transformer
ii Dismantling charges for conctrete with steel
reinforcement
Cmt
528
iii) Dismantling of concrete only
Cmt
256
iv) Dismantling charges in all other cases
44
Special Locality Allowance
Following places are eligible for extra locality
allowance ae:ainst each items on labour chare:es
a) Dakshina Kannada district
Bantwal, Mangalore, Sulya, Puttur, Belthangady
taluks.
b) UduJ>i : UduJ>i. Kundaour. Karkala Tas
c) Uttara Kannada District : Karwar, Supa, Haliyal,
Sirsi, Mundagodu, Yellapur, Bhatkal, Siddapur,
Honnavar. Kumta Ankola Ta s.
d) Kodagu District : Madikeri, Virajpet, Somarwarpet,
Tas.
e) Chikkamagalur District : Kadur, Chikkamagalur,
Koppal, Tarikere, Mudigere, Narasimharajapura,
Srine:eri Tqs.
I fl Shimoe:a District :
i) Hosangar, Thirthahally, Sagar, Sorab, Shikarpur Tqs
ii) Shimoe:a. Bhadravathi, Honnali Tqs
I 2) Davane:ere District : Chennae:iri Ta only
75% of erection charges in
general
35%
35%
35%
35%
25%
25%
.
15 %
15%
0 0 0 0 7 �.
SI.
No.
Discription
hi Dharwad District
ii Kal2ata2i
ii) Dharwad Ta
i) Haveri District :
ii Hangal, Herekerur
iii Byda2'.i, Shi2aon, Savanur Tas.,
Iii Bel2aum District
ii Khanauura Ta
Unit
220
KV
I
Amount in Rs.
1 10
66
KV
KV
I
25%
15%
25%
15%
25%
ii) Hukkeri, Belgaum, Bylahongal, Soundatti Taluk's
only.
15%
k) Mysore District : Heggadadevanakote, Hunsur Tqs
25%
1) Chamarajanagar District : Gundlupet,
Chamaraiana2'.ar. Kolle2al Tas
m) Hassan District : Sakaleshpur, Hassan, Arakalagud,
Belur. Alur, Taluks onlv.
Note:
1) In case of civil works where KPWD SR rates are
adopted, the locality allowance as applicable in KPWD
SR shall be followed.
2) J'or all other works the locality allowance as
indicated above shall be followed.
I
33
KV
25%
25%
. 000 0 7 5
Amount in Rs.
Sl No. Description
Unit
220
kV
45
Surveying of cable route excavation trial
holes as per field requirements,
preparation of cable route profile, drawings
1 for cable laying, final route alignment,
marking lines and grades, preparation of
final cable route, drawings after laying and
energising for preparing bill of materials.
kms.
68,807.70
1 10
kV
38,855.70
cable below footpath in the following
strata of soil by mechanical/ manual means
including removing and re-rixing the kerb
and pavement stone slabs, removing and
re-rixing masonry of other services with
patch work, deposition of earth/rock on
bank with all leads and lifts including
shoring, strutting, providing caution
boards, danger lighting, Bracing, sheeting ,
bailing out of water, barricades and other
works not specifically mentioned herein
but required for the completion of work in
all respects
-
a) Ordinary soil/ Black Cotton Soil
I--�
2 b) Hard soil
cl Hard Laterite Soil/Dry fissured rock.
d) In hard rock with chiseling and wedging
Cmt.
232.50
Cmt.
Cmt.
298.2 2
720.10
Cmt.
988.28
Cmt.
Cmt.
Cmt.
Cmt.
132.50
198.22
620.10
888.2 8
-
B) Earth work excavation for laying of UG
cable in open ground and beneath the road
surface in the following strata of soil by
mechanical/ manual means deposition of
earth/rock on bank with all leads and lifts
including shoring, strutting, providing
caution boards, danger lighting, Bracing,
sheeting, bailing out of water, barricades
and other works not specifically mentioned
herein but required for the completion of
work in all respects.
I--i--i---
a) Ordinarv soil/ Black Cotton Soil
bl Hard soil
cl Hard Laterite Soil/Dry fissured rock.
d) Hard rock with chiseline: and wede:ine:
38,855.70
Note:-1.Extra for excavation under water
condition and or foul conditions including
bailing/ pumping out removal of slush add
20% of the rate.
2. In the case of excavation for pits or
trenches of width more than 600mm and
less than 1500mm add 25% extra and for
width upto 600mm add 50% extra.
3.The indicated rates are applicable for
works in BBMP limits of Bangalore.For
other areas the rates of respective KPWD
Circles shall be considered.
4.No extra area weightage need to be
added to the rates inidcated here since
the PWD area weightage is already
considered
A) Earth work excavation for laying of UG
I---
66
kV
Amount in Rs.
Sl No. Description
Unit
220
1 10
66
kV
kV
kV
Note:1.The indicated rates are applicable for
works in BBMP limits of Bangalore.For
other areas the rates of respective KPWD
Circles shall be considered.
2 No extra area weightage need to be
added to the rates indicated here since
the PWD area weightage is already
considered
Cutting the road surface for laying of cable
& disposing of the excavation I debris with
all leads and lifts to any notified disposal
3 point of the local bodies/as directed
including providing barticading, danger
lighting/ caution boards etc., in the
following classifications of road surfaces
a) Macadam road surface
Cmt.
293.62
bl Asohalt surface
Cmt.
4 17.64
c) Cement concrete surface
Cmt.
665.68
Laying EHT single core, XLPE copper
cable in trefoil, tapping, fixing pipes for
drain and gate crossing as per drawings &
specifications in trench pipes, ducts by
pulling, drawing etc., including transport,
handling of cable drums, paving out cables
4 using standard cable installation
il:ms-ckt 1,900,402.53
equipments. NOTE: The quoted rate per
km shall include laying one circuit per km
each circuits consisting of 3 Nos. Single
core cables including transport of cable
drums material, equipments to site and
retaining unused items to stores.
•
5
Supplying and filling sieved/riddled sand of
approved quality in cable trenches
Cmt.
including all lead, lift, watering, ramming,
etc complete
Design, Engineering, supplying RCC
protection covers with M20 Grade concrete
and Fe 4 1 5 steel, handling and covering
the cables in the trench as per the drawing,
6
specifications and directions of the
Engineer in charge of the work
Back filling the cable trench with selected
available ridded earth from the trench
excavation & consolidating with ramming
7 in successive layers of 15 Cms thickness,
watering wherever necessary, achieving 96
% proctors density, forming a crown for
�
.
. .
728,9 10.00
62 1 ,69 1.20
1,274.00
Rate is same for all
capacity of cables.Refer
notes as in item 3.
Smtr
106 1.00
Rate is same for all
capacity of cables.The
rate is same for all circles
and areas.No extra
weightage to be added.
Cmt.
53.00
Rate is same for all
capacity of cables.Refer
notes as in item 3.
· -... --
0 00 01 1
Amount in Rs.
SI No. Description
Unit
220
kV
8
Disposal of surplus earth/rock to the areas
directed/notified areas of disposal point of
the local bodies including all lead and lift
charges loading, unloading etc complete
66
kV
1 10
kV
Rate is same for all
capacity of cables.Refer
notes as in item 3 .
Cmt.
174.48
Handling and making normal straight
9 joints for EHV power cables with all
consumables at site etc., complete.
Nos.
294,890.3 1
64,350.00
3 1 ,084.56
Handling and making of cables end
10 termination for EHV single core XLPE
copper cable.
Nos.
308,943. 18
64,350.00
3 1,084.56
Erection of cross bonding single phase
earth link boxes on to the cable mounting
1 1 structure connecting earth leads with all
lugs, f"ixtures, clamps bolts, and nuts
complete.
Nos.
28,084.68
23,3 13.42
23,3 13.42
Supplying, handling and fixing RCC cable
route markers and joint markers as per the
1 2 specifications, approved drawing and
directions of the Engineer in charge of the
work.
Design engineering, supply of all labour,
material and construction of RCC (M20
Grade) footings and pedestals of any
section/size including the cost of
excavation in all types of soil/rock, back
filling with available approved earth/new
earth, disposal of surplus earth/rock to the
places directed, concrete (M20 Grade and
lean concrete 1 :4:8), reinforcement steel,
1 3 form work, grouting, under pinning,
foundations strengthening in
expansive/BC soil, curing, sundries and
other items not mentioned herein but
required for the completion of work as per
technical specifications, approved drawing
and directions of engineer in charge of the
work.
For EHV cable termination structure
Nos.
230.00
Nos.
25,766.00
Rate is same for all
capacity of cables.The
rate is same for all circles
and areas.No extra
wei1Zhta11:e to be added.
7, 142.00
7, 142.00
00001 0
Amount in Rs.
SI No. Description
Unit
Design, Engineering and construction of
RCC Cable Joint Bays to accommodate
jointing of 3 Nos (Single Circuit)/ 6 Nos
(D,ouble Circuit) as required of single core
XLPE UG Cable as per specifications,
drawings and directions of the Engineer in
14
charge of the work. The bidders shall
inspect the site and quote duly furnishing
designs and drawings. The joint bays shall
be filled with riddled sand after completion
of all the other works viz., construction of
joint bay, laying of cable, testing etc.
a) for 220KV Cables
9.00xl.60xl.60 m clear
b)
for
66KV
Cables,
4.00xl.80xl.50m clear
size
size
of
of
bay
bay
Surface Restoration
Providing road restoration work consisting of
Granular Sub-Base, wet mix macadam,
bituminous macadam, bituminous concrete,
Primer Coat & Tack Coat as per BBMP
1 5 specifications /requirements and drawing
including cost of all materials, labour, over
heads, machineries etc., and directions of the
Engineer in charge of the work.
(Note: For detailed specifications KPWD SR of
Bangalore Circle and NH SR shall be referred.)
Cable trench clear width
Cable trench clear width
1.00mtr
220
kV
1 10
kV
66
kV
The rate is same for all circles and
areas.No extra weightage to be added.
Nos.
346,997.00
Nos.
176,323.00
Rmtr.
Rmtr.
1398.35
Rmtr.
1747.94
Rmtr.
262 1.9 1
1 .50mtr
00001 1
Amount in Rs.
SI No. Description
Unit
220
kV
Cable Crossing Arrangements:
Design, Engineering and construction of
Cable crossing arrangements at Rail,
Bridges & Culverts/ Storm water
drains/Water Supply Line, etc. The
arrangement shall accommodate 3 Nos
(Single Circuit)/ 6 Nos (Double Circuit) as
required of single core XLPE Cable.
Construction of crossing arrangements
shall include RCC cable ducts, RCC/Stone
Masonry piers, abutments, Wing walls,
16
Returns, Wall foundations, etc. The
bidders shall inspect the site and quote
duly furnishing designs and drawings. The
successful bidders shall furnish the designs
and drawings in accordance with the
requirements of the statutory authorities
(National & State High ways, BBMP,
Railways, BWSSB, BSNL, KPTCL/BESCOM
etc.) and execute the work as per the
approved drawing and directions of the
Engineer in charge of the work.
Cement concrete 1 :2:4: Providing and
laying site mix/Ready mixed cement
concrete of 1:2:4 proportion for embedding
the HDPE pipes in road crossings and for
other works using 20mm and down size
granite jelly and clean sieved sand laid in
15cm thick layers and well compacted
including vibrating, curing etc with all lead
and lift, smooth finishing for exposed faces
and with necessary centering and form
work etc complete.
1 10
kV
66
kV
Rmtr.
The rates to be arrived based on the
drawing and site requirement.The
estimates shall be prepared in
consultation with civil engineers of the
circle
Cmtr
4,327.98
Horizontal trench less cutting: Design of
cable crossing arrangement at highway
using HDD arrangement shall
�kt-mtr
19
accommodate crossing of XPLE UG cable
.The work shall be carried out as per the
directions of KPTCL in charge of the work.
17,550.00
1 1 ,700.00
1 1,700.00
Laying of 12 Fibre Dual Window Mono
20 Mode (DWMM) Optical Fibre Cablea as per
drawinizs & soecifications.
kms.
6,000.00
6,000.00
6,000.00
Handling and making straight through
21 joints closures for 12 Fibre Dual Window
Mono Mode (DWMM) Optical Fibre Cable
Nos.
14,063.86
14,063.86
14,063.86
ooooau
Amount in Rs.
SI No. Description
Unit
220
kV
1 10
kV
66
kV
Handling and making terminal joints for 1 2
22 Fibre Dual Window Mono Mode (DWMM)
Nos.
16,850.34
1 6,850.34
16,850.34
Optical Fibre Cable
Supplying and providing PVC warning
Tapes 150mm wide & 100 Microns thick as
23
Rmtr
per specifications, drawings and directions
of the Engineer in charge of the work.
-----
HDPE Pipes: Supplying & providing HDPE
pipe 6 mm thickness (as per IS 4984) with
24 necessary accessories for road crossing,
drive ways etc
1 60mm dia
a)
b)
230mm dia
Rmtr
Rmtr
45.00
2,050.00
ooooa 1
PART III: SCHEDULE O F RATES FOR REPAIR OF POWER TRANSFORMER
Sl.
No.
DESCRIPTION OF WORKS
UNIT
1
Draining out oil from the Power Transformer complete
collecting the oil in barrels (supplied by KPTCL) shifting
barrels t o safe place (in the station premises only) with
proper tightness of cork/lid to avoid entry of moisture.
Ltrs.
1.17
2
Unloading of the Faulty Transformer tank with active
parts of accessories at firm's work or loading of repaired
Transformer tank with active parts o r accessories at
firm's works
MT
171
3
Dismantling faulty transformer for joint inspection at
repairers premises including all activities such as
opening of top cover, de-tanking of core and winding,
separation of HV/LV coils, conducting of preliminary
test required for assessment of repair work to be
undertaken, dismantling core etc., in the presence of
KPTCL authorised representative.
Amount in Rs.
5 MVA
6.3 MVA
S MVA
lO MVA
12.5 MVA
16/20 MVA
17097
17097
25645
40410
4274 1
5 1290
3 1 .5MVA
5 1290
4
5 MVA
6.3 MVA
Providing new windings in place of damaged winding
S MVA
including cost of materials, labour, drying etc., (Both HV
lO MVA
& LV) - per Kg of winding
12.5 MVA
16/20 MVA
3 1.5MVA
933
933
933
933
933
933
933
5
Providing solid insulation materials for replacement to
damaged or burnt insulation as per actual weight.
Kgs.
466
Providing re-insulation to HV/ LV winding whenever
necessary for total weight of winding except solid
insulation
Kgs.
171
Providing new CRGO lamination to the core in place of
damaged lamination wherever necessary including cost
of materials and labour.
Kgs.
435
Repair and overhauling of OLTC each Divertor switch
including change of oil, lubrication and replacement of
gaskets and other parts which are locally available
5 MVA
6.3 MVA
S MVA
lO MVA
12.5 MVA
16/20 MVA
3 1.5MVA
Spares for OLTC/Divertor switch (spares to be procured
.
from the o rie:inal manufacturers onlv)
LS
6
7
17097
17097
25645
25645
34193
34 193
34 193
As per Actuals
o o o o ai
1
SI.
No.
DESCRIPTION OF WORKS
8
Cleaning, Repairing and painting inside the Transformer
Tank with hot oil bath and acid proof epoxy paint and
painting outside the tank with enamel paint after
thorough cleaning including the cost of materials
including the painting of radiators at site/Firm.
9
Re-assembly of Core and winding
Drying out the assembly of core and winding in oven/
vacuum chamber, till the specified insulation resistance
10
values are obtained (including cost o f materials and
labour)
Tanking the assembly, giving connection, providing new
gaskets and insulating materials conforming to relevant
ISS, putting back the cover, tightening the fixtures,
1 1 fixing the bushing etc., including the cost of all
materials like Gasket, insulating materials, Bolts and
Nuts etc., and labour. Other accessories at repairers
work to facilitate the testing.
Filling of oil to the main tank and OLTC tank, filtering
the oil including filtering till attainment of prescribed
BDV valves including labour, filtering equipment along
12
with accessories. The minimum BDA value shall be
50KV. Note: The Transformer oil will be supplied by
KPTCL.
Spares for Transformer such as Bushing, Oil gauge,
13 valves etc., which shall be procured from the orginal
manufacturers.
14 Other snares
a) Testing the transformer for routine tests as per IS
2026-1983 if repairs are carried out at Repairer's work.
b) Testing the transformer for IR values, Voltage ratio at
1 5 all Taps, Short circuit test, Magnetic balance,
Magnetising current measurement at low voltage from
HV & LV. Magnetising current measurement at rated
voltage from LV side.
UNIT
5 MVA
6.3 MVA
8 MVA
lO MVA
12.5 MVA
16/20 MVA
3 1 .5MVA
5 MVA
6.3 MVA
8 MVA
l O MVA
12.5 MVA
16/20 MVA
3 1 .5MVA
5 MVA
6.3 MVA
S MVA
lO MVA
12.5 MVA
16/20 MVA
Amount in Rs.
1865 1
1865 1
22536
34 193
34 193
37301
37301
17097
17097
25645
48 1 8 1
54398
59838
59838
2 1 760
2 1760
32638
606 1 5
69940
76 158
3 1.5MVA
5 MVA
6.3 MVA
S MVA
lO MVA
12.5 MVA
16/20 MVA
76 158
12822
25645
25645
25645
34193
34 193
3 1.5MVA
34 193
5
Ltrs.
LS
Actuals
LS
Actuals
S MVA
17097
6.3 MVA
S MVA
25645
34193
l O MVA
34 193
12.5 MVA
34 193
16/20 MVA
34 193
-..
000033
2
Sl.
No.
DESCRIPTION OF WORKS
16 Providiniz: new Transformer Oil
17 Transit risk insurance
18
Supervising and commissioning of Transformer in the
presence of RT Staff as and when the Transformer is
ready for commissioning
'
19
I
Scrap value of Copper.Iron and CRGO sheets
a) Scrao Cooper
b) Scrap Iron
cl Scrap CRGO
UNIT
3 1 .5 MVA
Ltre.
LS
Amount in Rs.
34 193
89.00
As per actuals
S MVA
6.3 MVA
S MVA
lO MVA
12.5 MVA
16/20 MVA
3 1 .5MVA
8548
8548
8548
13988
13988
13988
1 3988
Rate / ke:
Rate/ kg
Rate / ke:
3 1 5.9
1 9.89
52.65
3
Download