ul test report and procedure

advertisement
Issue Date:
2012-06-08
Page 1 of 12
Report Reference #
E210619-A320-UL
2012-06-14
UL TEST REPORT AND PROCEDURE
Standard:
Certification Type:
CCN:
Product:
Model:
Rating:
UL 60950-1, 2nd Edition, 2011-12-19 (Information Technology
Equipment - Safety - Part 1: General Requirements)
CSA C22.2 No. 60950-1-07, 2nd Edition, 2011-12 (Information
Technology Equipment - Safety - Part 1: General Requirements)
Listing
NWGQ, NWGQ7 (Information Technology Equipment Including
Electrical Business Equipment)
Access Controller
AC6605-26-PWR
Input (for each power module):
100-240 Vac; 50/60 Hz; 7-3.5 A (500W);
or 100-240 Vac; 50/60 Hz; 3 A (150W);
or -48Vdc -- -60Vdc; 6 A (150W).
(optional) POE output (each): 48Vdc, maximum 30W. (available when
500W power supply equipped, and 360W POE power output apiece)
Applicant Name and Address:
HUAWEI TECHNOLOGIES CO LTD
BANTIAN
LONGGANG DISTRICT
SHENZHEN
GUANGDONG 518129 CHINA
This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the
above referenced Standards. The products have been found to comply with the requirements covering the category and the products are
judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on
such products which comply with this Test Report and any other applicable requirements of UL LLC ('UL') in accordance with the FollowUp Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up
Service under the indicated Test Procedure.
The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety.
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL.
Prepared by:
Bobby Liu
Reviewed by: Glenn Liu
Copyright © 2012
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
Issue Date:
2012-06-08
Page 2 of 12
Report Reference #
E210619-A320-UL
2012-06-14
Supporting Documentation
The following documents located at the beginning of this Procedure supplement the requirements of this Test
Report:
A. Authorization - The Authorization page may include additional Factory Identification Code markings.
B. Generic Inspection Instructions i. Part AC details important information which may be applicable to products covered by this Procedure.
Products described in this Test Report must comply with any applicable items listed unless otherwise
stated in the body of this Test Report.
ii. Part AE details any requirements which may be applicable to all products covered by this Procedure.
Products described in this Test Report must comply with any applicable items listed unless otherwise
stated in the body of each Test Report.
iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical
standard used to investigate these products. Products are permitted to bear only the Certification
Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report.
Product Description
Routing and gateway devices consisted of UL R/C power supply module, functional boards, DC fans; all
these parts were housed in a metal enclosure.
Power supply module including: 500W AC-DC, 150W AC-DC, 150W DC-DC, alternate for each other. Only
when 500W power supply equipped the POE ports would be available, each 500W AC-DC Power supply
module supplies 12 POE ports. The 48Vdc output of each 500W PSU directly supplies to POE board via
fuse.
Model Differences
N/A
Technical Considerations

Equipment mobility : fixed

Connection to the mains : For AC input: Pluggable equipment type A; For DC input: permanent
connection

Operating condition : continuous

Access location : restricted access location

Over voltage category (OVC) : OVC II

Mains supply tolerance (%) or absolute mains supply values : For AC input: ±10%; For DC input:
±20% (Declared by manufacturer)

Tested for IT power systems : No
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
Issue Date:
2012-06-08
Page 3 of 12
Report Reference #
E210619-A320-UL
2012-06-14

IT testing, phase-phase voltage (V) : N/A

Class of equipment : Class I (earthed)

Considered current rating of protective device as part of the building installation (A) : AC: 20A. DC:
10A

Pollution degree (PD) : PD 2

IP protection class : IP X0

Altitude of operation (m) : maximum 2000

Altitude of test laboratory (m) : less than 2000

Mass of equipment (kg) : 7.56 kg (Declared by Manufacturer)

The product was submitted and evaluated for use at the maximum ambient temperature (Tma)
permitted by the manufacturer’s specification of: 50 degree C.

The means of connection to the mains supply is: Detachable power cord, Pluggable A for AC input;,
Permanently connected (field wired) for DC input.

The product is intended for use on the following power systems: TN or DC mains supply.

The equipment disconnect device is considered to be: Appliance inlet for AC input;, Switch for DC
input.

The class of laser product is: Class 1 (I)

The following circuit locations (with circuit/schematic designation) were investigated as a limited
power source (LPS): POE ports

The following are available from the Applicant upon request: Installation (Safety) Instructions /
Manual

The power supply in this equipment was: UL 60950-1, 2nd Edition and CSA C22.2 No. 60950-1-07,
2nd Edition.

LEDs provided in the product are considered low power devices: Yes

The AC power module and DC power module (with recognized power supply) in this equipment was
investigated to UL 60950-1, 2nd Edition / CSA C22.2 No. 60950-1-07, 2nd Edition in E210619-A312.
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
Issue Date:
2012-06-08
Page 4 of 12
Report Reference #
E210619-A320-UL
2012-06-14
And the Clearances and Creepage Distances have additionally been assessed for suitability up to
3000 m elevation.

The output connectors listed in critical component list was subjected to Connector Current
Interruption test during the end product certifications. (200 insertion/withdrawal cycles at 150% of
normal load current, after normal heating test.)
Additional Information
N/A
Markings and instructions
Clause Title
Marking or Instruction Details
Power rating - Ratings
Ratings (voltage, frequency/dc, current)
Power rating Company identification
Power rating -
Listee's or Recognized company's name, Trade Name, Trademark or File
Number
Model Number
Model
Disconnect device Permanently connected
Statement indicating that a readily accessible disconnect device shall be
equipment
incorporated in the building installation wiring. (Instruction)
Fuses - Non-operator
access/soldered-in
fuses
Terminal for main
protective earthing
Unambiguous reference to service documentation for instructions for
replacement of fuses replaceable only by service personnel
Provided adjacent to the main protective earthing terminal (60417-5019)
Symbols - On/Off switch
All other controls to be marked with
symbol for "ON" (60417-2-IEC-5007) and
symbol for "OFF" (60417-2-IEC-5008)
Multiple power sources
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
Issue Date:
2012-06-08
Page 5 of 12
Report Reference #
E210619-A320-UL
2012-06-14
"Disconnect ___ power supply cords before servicing"
Replaceable batteries
"CAUTION: Risk of Explosion if Battery is replaced by an Incorrect Type.
Dispose of Used Batteries According to the Instructions."
Restricted Access
Location
"Equipment intended for installation in Restricted Access Location" or
equivalent. (Instruction)
Short
Circuit/Overcurrent
Installation Instructions indicate Listed circuit breaker or branch rated fuse,
protection for Pluggable rating, number of poles, special characteristics.
B or permanently
connected equipment
Stability
Installation Instruction states the product is to be secured to building before
operation. (Instruction.)
Laser - Compliance to
CFR 1040.10, etc.
Laser - mfr./date
"Complies with 21 CFR 1040.10 and 1040.11."
"Manufactured (month/year) __________"
Protective device
It is required to use a fuse or circuit breaker not larger than 10 A in the DC
input for DC input model.
Polarity marking
Polarity of DC input was marked adjacent to the dc mains terminals for DC
for DC power
input model
equipment
Special Instructions to UL Representative
N/A
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
Issue Date:
2012-06-08
Page 6 of 12
Report Reference #
E210619-A320-UL
2012-06-14
Production-Line Testing Requirements
Electric Strength Test Special Constructions - Refer to Generic Inspection Instructions, Part AC for
further information.
Model
Component
Removable
Parts
Test probe location
V
rms
V dc
Test Time,
s
--
--
--
--
--
--
--
Earthing Continuity Test Exemptions - This test is not required for the following models:
-Electric Strength Test Exemptions - This test is not required for the following models:
500W AC power module.
Electric Strength Test Component Exemptions - The following solid-state components may
disconnected from the remainder of the circuitry during the performance of this test:
Gas tube on the power supply if provided.
Sample and Test Specifics for Follow-Up Tests at UL
Model
N/A
Component
N/A
Material
N/A
Test
N/A
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
Sample(s)
N/A
Test
Specifics
N/A
Issue Date:
2012-06-08
Page 7 of 12
Report Reference #
E210619-A320-UL
2012-06-14
1.5.1
TABLE: list of critical components
Object/part or
Description
Manufacturer/
trademark
type/model
1. Cabinet: Enclosure
-
-
Pass
technical data
Product Category Required
Marks of
CCN(s)
Conformity
-
Steel; 442mm by 43.6mm by
420mm, 1mm thick minimum.
Secured by screws.
Numerous openings, measured
max. 5mm in any direction;
covered area 163mm by
26mm, 144mm by 26mm at left
side; 33mm by 26mm for fan at
right side; and 33mm by 31mm
on rear side.
1-1. Cabinet: Earthing or Screws type; each 4mm
bonding terminal
diameter; one provided,
earthing marking provided near
the terminal (60417-2-IEC5019).
2. Label
150 degree C, suitable for
PGDQ2, PGJI2
application to metal.
3. Fan (three used)
ASIA VITAL
DBTA0420B2UP0 12 Vdc, 0.41 A. (20.13 CFM
GPWV2
32030090
COMPONENTS CO., 11
declared by manufacturer)
LTD
3a. Alternate
DELTA
TAA0412CD12 Vdc, 0.43 A. (20.56 CFM
GPWV2
ELECTRONICSIN
AF83
declared by manufacturer)
4. 150W AC power
--R/C open frame housed in
-module
metal enclosure, see detailed
construction as below.
4-1. AC Power supply
VAPEL
PSC150-12A
Input: 100-240Vac; 50/60Hz,
QQGQ2
board in AC power
3A max;
module
Output: 12Vdc, 12.5A
maximum. (Tma 55 degree C,
Altitude 3000m)
4-1a. -alternative
FSP
PSC150-12A
Input: 100-240Vac; 50/60Hz, 3- QQGQ2
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
-
UL
UL
UL
-UL
UL
Supplement ID
Issue Date:
2012-06-08
Page 8 of 12
Report Reference #
E210619-A320-UL
2012-06-14
4-2. Enclosure for AC
power module
--
4-3. AC appliance inlet
for AC power module
(14190022)
4-4. AC input switch for
AC power module
16040055
Rong Feng Industrial SS-120
Co.,Ltd
4-4a. -alternative
4-5. Internal input wire
for AC power module
PRONIC
ELECTRONICS
(SHENZHEN) CO
LTD
SOLTEAM
ELECTRONICS CO
LTD
Various
--
1.5A;
Output: 12Vdc, 12.5A
maximum. (Tma 55 degree C,
Altitude 3000m)
Steel, min. 0.9 mm thick,
-overall 196mm by 90mm by
40mm. Numerous square
openings, measured max. 3mm
in any direction, covered
172mm by 23mm on left and
right sides.
250Vac, 10A, 105 degree C.
AXUT2
--
UL
R130-22C-11P-A
250Vac/5A, 125Vac/10A, 55
degree C.
WOYR2
UL
MR-21 series
250Vac, 10A, 65 degree C.
WOYR2
UL
Various
WV-1 or FT-1, minimum 300V, AVLV2
minimum 18AWG, minimum 85
degree C.
Green and Yellow insulation.
AVLV2
WV-1 or FT-1, minimum 300V,
minimum 18AWG, minimum
105 degree C.
Minimum 85 degree C.
ECBT2
UL
Minimum 85 degree C.
UL
4-6. Bonding wire for AC Various
power module
Various
4-7. Output connector for TYCO
AC power module
ELECTRONICS
CORP
4-7a. -alternative
CHINA AVIATION
OPTICALELECTRICAL
TECHNOLOGY CO
LTD
2-6450130-9
DP2TJW0424001
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
ECBT2
UL
UL
Issue Date:
2012-06-08
Page 9 of 12
Report Reference #
E210619-A320-UL
2012-06-14
4-7b. -alternative
FCI USA L L C
4-8. LED secondary wire Various
51730-016LF
Various
4-9. Heat shrinkable
tubing
Various
Various
4-10. Insulation sheet
between AC Power
supply board and
Enclosure of AC power
module
5. 150W DC power
module
MIANYANG
PC-860-60B
LONGHUA FILM CO
LTD
--
5-1. DC/DC convertor on Astec International
DC Power module
Ltd
(02280790)
5-1a. -alternative
VAPEL
5-1b. -alternative
Huawei
5-2. Enclosure for DC
power module
--
--
Minimum 85 degree C.
WV-1 or FT-1, minimum 300V,
minimum 22AWG, minimum
105 degree C. Protected by
heat sinkable tubing
Minimum 300V, 105 degree C,
VW-1. Minimum 0.4 mm
thickness after shrank.
Minimum 0.25 mm thick, rated
V-0, 80 degree C. 188 by 95
mm for bottom and 167 by 86
mm for top.
R/C DC/DC convertor mounted
on Filter circuit PWB and
housed in metal enclosure, see
detailed construction as below.
AVE360-48S12-4 Rated input: 36-75V/12A;
Rated output: 12V/30A. (EP:
15A, Tma 85 degree C, Altitude
3000m)
NH360S48K-B
Rated input: 36-75 V/11.6 A;
Rated output: 12 V/30 A. (EP:
20A. Tma 75 degree C, Altitude
4000m)
GAH30S12
Rated input: 36-75 V/13 A;
Rated output: 12 V/30 A. (EP:
20A. Tma 84 degree C, Altitude
4000m)
-Steel, min. 0.9 mm thick,
overall 196mm by 90mm by
40mm. Numerous square
openings, measured max. 3mm
in any direction, covered
172mm by 23mm on left and
right sides.
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
ECBT2
AVLV2
UL
UL
YDPU2
UL
QMFZ2
UL
--
--
QQGQ2
UL
QQGQ2
UL
QQGQ2
UL
--
--
Issue Date:
2012-06-08
Page 10 of 12
Report Reference #
E210619-A320-UL
2012-06-14
5-3. Input terminal for
DC Power module
Various
Various
5-4. DC input switch for
DC power module
PRONIC
ELECTRONICS
(SHENZHEN) CO
LTD
SOLTEAM
ELECTRONICS CO
LTD
Various
R130-22C-11P-A
5-4a. -alternative
5-5. Internal input wire
for DC power module
Supporting plastic material
QMFZ2
rated minimum V-1, minimum
85 degree C, and minimum 1
mm thick. Two screw terminals,
each diameter not less than 3.5
mm.
250Vac/5A, 125Vac/10A, 55
WOYR2
degree C.
UL
MR-21 series
250Vac/10A, 65 degree C.
UL
Various
WV-1 or FT-1, minimum 300V, AVLV2
minimum 18AWG, minimum 85
degree C.
Minimum 85 degree C.
ECBT2
UL
DP2TJW0424001
Minimum 85 degree C.
ECBT2
UL
51730-016LF
Various
Minimum 85 degree C.
WV-1 or FT-1, minimum 300V,
minimum 22AWG, minimum
105 degree C.
Minimum V-2 or VTM-2,
minimum 125 degree C,
minimum 0.25mm.
ECBT2
AVLV2
UL
UL
QMFZ2 or
QMTS2
UL
WOYR2
UL
5-6. Output connector for TYCO
DC power module
ELECTRONICS
CORP
5-6a. -alternative
CHINA AVIATION
OPTICALELECTRICAL
TECHNOLOGY CO
LTD
5-6b. -alternative
FCI USA L L C
5-7. LED secondary wire Various
2-6450130-9
5-8. Insulation sheet
between DC/DC
convertor and Enclosure
of DC power module
05-9. Fuse F1, F2
05-9a. Fuse F1, F2
(alternate)
05-10. Fuse F3
Various
Various
BEL FUSE INC
LITTELFUSE INC
SSQ
448
15 A, 86 Vdc
15 A, 65 Vdc
JDYX2
JDYX2
UL
UL
BEL FUSE INC
SSQ
1 A, 125 Vdc
JDYX
UL
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
UL
Issue Date:
2012-06-08
Page 11 of 12
Report Reference #
E210619-A320-UL
2012-06-14
05-10a. Fuse F3
(alternate)
05-10b. Fuse F3
(alternate)
LITTELFUSE INC
451
1 A, 125 Vdc
JDYX
UL
CONQUER
ELECTRONICS CO
LTD
FSP
SEF
1 A, 125 Vdc
JDYX
UL
W2PSA0500
QQGQ2
UL
6-a. -alternative
Vapel
W2PSA0500
QQGQ2
UL
7. Li battery U85 on
H852V26S board
24010011
8. Fuse F1,F2,F3,F287
on H852V26S board,
19040105
8a. - alternate
8b. - alternate
9. Laser transceiver
10. PCB
11. SELV Connectors
11a. -alternative
PANASONIC
BR-2032/HFN
BBCV2
UL
CONQUER
ELECTRONICS CO
LTD
BEL FUSE INC
LITTELFUSE INC
Various
Various
Various
Various
SEF012
Input: 100- 240Vac, 50/60Hz,
7- 3.5A;
Output: 12Vdc, 10A; 53.5Vdc,
7.1A. (Tma 55 degree C,
Altitude 3000m)
Input: 100- 240Vac, 50/60Hz,
7- 3.5A; output: 12Vdc, 10A;
53.5Vdc, 7.1A. (Tma 55 degree
C, Altitude 3000m)
3.0Vdc, 0.190 Ah. Max
Abnormal Charging Current 5
mA.
65 Vac/dc,24 Vdc, 12 A
JDYX2
UL
JDYX2
JDYX2
NWGQ2
ZPMV2
ECBT2
QMFZ2
UL
UL
UL
UL
UL
UL
12. Internal Plastic Part
Various
Various
125 Vac/86 Vdc, 12 A
125 Vac/ dc, 12 A
3.3V/5.0V, Class 1 laser.
V-0, minimum 130 degree C.
Minimum 85 Degree C.
Copper alloy pins housed in
plastic bodies minimum V-2,
Minimum 85 Degree C.
Minimum V-2
QMFZ2
UL
6. 500W AC power
module 02130983
SSQ12
0451001.MRL
Various
Various
Various
Various
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
Issue Date:
2012-06-08
Page 12 of 12
Report Reference #
2012-06-14
Enclosures
Type
Supplement Id
Description
Photographs
3-01
Top, front and left view
Photographs
3-02
Rear, bottom and right view
Photographs
3-03
Internal view of EUT
Photographs
3-04
PE terminal of EUT
Photographs
3-05
Warning label
Photographs
3-06
AC input terminal of W2PSA500
Photographs
3-07
150W AC input connector view
Photographs
3-08
150W DC input connector view
Photographs
3-09
Overall view of VAPEL AC PSU (W2PSA500)
Photographs
3-10
Overall view of FSP AC PSU (W2PSA500)
Photographs
3-11
Overall view of 150W AC PSU
Photographs
3-12
Overall view of 150W DC PSU
Photographs
3-13
Inside view of FSP AC PSU (PSC150-12A)
Photographs
3-14
Inside view of VAPEL AC PSU (PSC150-12A)
Photographs
3-15
Inside view of 150W DC PSU
Photographs
3-16
H852V26S board
Photographs
3-17
LS221POE card
Photographs
3-18
LS521CTL card
7-01
Functional Board List
Diagrams
Schematics + PWB
Manuals
Miscellaneous
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
E210619-A320-UL
File E210619
PHO-01
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
File E210619
PHO-02
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
File E210619
PHO-03
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
File E210619
PHO-04
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
File E210619
PHO-05
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
File E210619
PHO-06
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
File E210619
PHO-07
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
File E210619
PHO-08
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
File E210619
PHO-09
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
File E210619
PHO-10
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
File E210619
PHO-11
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
File E210619
PHO-12
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
File E210619
PHO-13
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
File E210619
PHO-14
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
File E210619
PHO-15
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
File E210619
PHO-16
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
File E210619
PHO-17
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
File E210619
PHO-18
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
File E210619
MIS-01
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
Issue Date:
2012-06-08
Page 1 of 2
Revision Date: 2012-06-14
Test Record
Report Reference #
E210619-A320-UL
Test Record No. 1
Manufacturer submitted representative production samples of Access Controller, Model AC6605-26-PWR
for investigation.
Only limited tests were considered necessary due to previous investigation.
Limited Power Source Measurements (2.5) - Referred to E210619-A311, with the same POE board used.
Connector Current Interruption (4.3.5) - For 500W power modules evaluated in previous evaluation. For
150W power modules referred to E210619-A312.
Unless otherwise noted, all tests were conducted in HUAWEI TECHNOLOGIES CO LTD under CTDP
program.
The following tests were conducted:
Test
Testing Location/Comments
End Product Reference Page
General Guidelines
Power Supply Reference Page
Input: Single-Phase (1.6.2)
Durability of Marking (1.7.11)
Protective Bonding II (2.6.3.4, 2.6.1)
Humidity (2.9.1, 2.9.2, 5.2.2)
For 150W AC and DC power
modules. Also can be referred to
E210619-A312, which with the same
power modules.
Steady Force (4.2.1 - 4.2.4)
Impact (4.2.5, 4.2.1, Part 22 10.2)
Heating (4.5.1, 1.4.12, 1.4.13)
Touch Current (Single-Phase; TN/TT System) (5.1, Annex D)
Electric Strength (5.2.2)
Abnormal Operation (5.3.1 - 5.3.9)
Overload of Operator Accessible Connector (5.3.7)
Test results are valid only for the tested equipment. These tests are considered representative of the
products covered by this Test Report. The test methods and results of the above tests have been reviewed
and found to be in accordance with the requirements in the Standard(s) referenced at the beginning of this
Test Report.
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
Issue Date:
2012-06-08
Page 2 of 2
Revision Date: 2012-06-14
Test Record
Report Reference #
E210619-A320-UL
The following tests were waived:
Test
Rationale for Waiving
Limited Power Source Measurements (2.5)
Referred to E210619-A311, with the
same POE board used.
Connector Current Interruption (4.3.5)
For 500W power modules evaluated
in previous evaluation. For 150W
power modules referred to E210619A312.
Lithium Battery Reverse Current Measurement (4.3.8)
Test was waived as Vmax (3.3Vdc) /
R322 (1K ohm) = 0.0033mA < Max
Abnormal Charging Current (5mA) of
battery coin (BR2032).
The following supplements are provided as a part of this Test Record. NOTE: These supplements are only
available to the Applicant via the CDA system.
Type
Supplement Id
Description
Attachment
2-01
CRD
Datasheet
2-02
1-datasheet-01
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
File E210619
01-ATT-01
Created by UL Document Assembler 2012-06-14 21:03:23 -05:00
Download