Proposed Interior Fit-Out for the Department of Tourism
Showroom in New York City, USA; Philippine Center
565, 5th Avenue , New York City, NY 10036, USA
Technical Specifications
SECTION 28 23 00
VIDEO SURVEILLANCE
PART 1
GENERAL
1.1
SCOPE OF WORK
This section shall include all management, labor, materials, tools, equipment and
services required to manufacture, assemble, deliver (including all import and export
documents), and install all items necessary for the proper execution and completion
of a close circuit television CCTV System, as indicated in the General and Special
Conditions of the Contract Documents, the Drawings, as specified herein, and/ or as
required by job conditions.
1.2
REFERENCES
The following standards form part of these specifications to the extent referenced, in
accordance to the requirements under General Conditions of the Contract Documents
and Manufacturer’s instructions:
1.2.1 Conformity for Europe (CE)
1.2.2 Federal Communications Commission (FCC)
1.2.3
1.2.4
1.2.5
1.2.5
1.2.6
1.3
Underwriters Laboratories, UL
EU: EN 60950-1:2006 – Information Technology Safety
US: UL60950-1 – Information Technology Safety
EMC Standards (European or US standards)
Power Supply Standards – CE, UL, cUL, PSE, CCC
SUBMITTALS
Submit the following in accordance with the General Conditions of Contract and
requirements specified herein:
1.3.1
Manufacturer’s data sheets on each product to be used, including
documentation within thirty calendar days after award of the purchase
order. Indicated in the document will be the type, size, rating, style, catalog
number, manufacturer’s names, photos, and/ or catalog data sheets for all
items proposed to meet these specifications. The proposed equipment shall
be subject to the approval of the Architect/ Engineer and no equipment shall
be ordered or installed on the premises without that approval.
1.3.2 Shop Drawings:



Connection diagrams for interfacing equipment.
List of connected equipment.
Locations for all major equipment components to be installed under
this specification.
Note: All Shop Drawings shall be submitted prior to purchasing and installing of
materials for review and approval of the Architect.
Arce•Bailon•Arce Architects
28 23 00 / Video Surveillance - Page 1 of 3
Proposed Interior Fit-Out for the Department of Tourism
Showroom in New York City, USA; Philippine Center
565, 5th Avenue , New York City, NY 10036, USA
Technical Specifications
1.4
QUALITY ASSURANCE
1.4.1 Comply with quality assurance requirements, under General Conditions of
the Contract Documents and Manufacturer’s instructions.
1.4.2 Manufacturer’s Qualification:
Manufacturer shall be certified as being compliant with ISO9001
1.5
DELIVERY, STORAGE AND HANDLING
Comply with the provisions under General Conditions of the Contract Documents and
Manufacturer’s instructions. Delivery of materials shall be so scheduled as to allow
for immediate installation. Products shall be protected and kept under cover with
manufacturer’s standard protective packaging during transit and at the jobsite.
Manufactured materials shall be delivered in the manufacturer’s original unbroken
packages or containers that are labeled plainly with the manufacturer’s name and
brands. Materials shall be stored in any weather-tight enclosures, and shall be
handled in a manner that will prevent damage until installation.
1.6
WARRANTY
Special written warranty for each material specified herein shall be submitted by
Manufacturer/ Contractor without reducing or otherwise limiting any other rights to
correction which the Owner may have under the contract Documents. Failures are
defined to include faulty workmanship or faulty materials.
1.7
COORDINATION WITH OTHER TRADES
Ensure that locating templates and other information required prior installation of
materials under this section is furnished in time to affected trades to prevent
interruption of construction progress.
1.8
PROJECT CONDITIONS
Comply with field examination requirements under General Conditions of the
Contract Documents and Manufacturer’s instructions. Maintain environmental
conditions including temperature, humidity, and ventilation, within limits
recommended by manufacturer for optimum results. Do not install products under
environmental conditions outside manufacturer’s absolute limits.
PART 2
2.1
PRODUCTS
Security Access and Surveillance
Reference distributer shall be “Stellar Equipment & Machinery Inc.”, “Systems
Variable”, “EVI Distribution Inc.” or approved equal. Submit shop drawings for
Architect’s approval.
Note: Submit product catalog and shop drawings from the manufacturer’s standard
layout, details and installation for Architect’s approval, before installing and
roughing-ins of cables, conduits and fixtures. Submitted shop drawings shall
be based on the actual measurements and conditions of the site. Required
brand/manufacturer shall be UL approved and complying with required
standards.
Arce•Bailon•Arce Architects
28 23 00 / Video Surveillance - Page 2 of 3
Proposed Interior Fit-Out for the Department of Tourism
Showroom in New York City, USA; Philippine Center
565, 5th Avenue , New York City, NY 10036, USA
Technical Specifications
2.1.1
CCTV Conduits and Pipes
Wiring connections shall be provided with roughing-ins. PVC Conduits shall
be Schedule 40, complete with fittings and accessories for site conduits. Use
Intermediate Metal Conduit (IMC) for building conduits. Complete with all
necessary accessories and local materials needed for the system
connections.
2.1.2
CCTV Cables and Wires
Shall be CAT-6 cable for equipment and 1.5-mm2 (16 AWG) twin-twisted
wire with a common sheath for speakers. Comply with the requirement
quality standard.
PART 3
EXECUTION
3.1
Manufacturer’s Instruction
Comply with manufacturer’s product technical data, installation procedures and
standards as per project requirement in accordance to NFPA, local fire code and
standards applicable.
3.2
Field Examination and Wiring
3.2.1 Submission of a proposal confirms that the contract documents and site
conditions are accepted without qualifications unless exceptions are
specifically noted.
3.2.2 The site shall be visited on a regular basis to appraise ongoing progress of
other trades and contractors, make allowances for all ongoing work, and
coordinate the requirements of this contract in a timely manner.
3.2.3 All Multiplexers must be inspected before installation, and shall be free of
any cosmetic defects or damage.
3.3
Installation
Furnish and install, all equipment and devices where shown on the drawings, the
following applicable codes, standards and manufacturer recommendation to ensure
proper operations and functions as intended. Perform preliminary test during
installation of wiring and system components. Correct any deficiency pertaining to
these requirements prior to functional and operational tests of the system.
Protection
All installations shall be protected with coverings as per manufacturer’s
recommended material. Replace damaged or defective items caused by subsequent
construction activities.
3.4
3.5
Adjusting and Testing
Before the installation shall be considered completed and acceptable by the awarding
authority, test each system to demonstrate.
END OF SECTION