Cordis EMPIRA NC ™ RX PTCA Post-Dilatation Catheter EMPIRA™ NC Balloon Catheter: Best-in-class controlled growth EMPIRA™ NC Balloon Catheter delivers crossability & best-in-class controlled growth to a wide range of lesions EMPIRA™ NC: More Non-Compliant than other PTCA Balloons2 EMPIRA™ NC: The most Non-Compliant Balloon Compliance Curve EMPIRA™ NC Quantum™ Maverick™ NC Quantum Apex™ x NC Trek NC Sprinter™ Hiryu™ RX PTCA Post-Dilatation Catheter EMPIRA NC RX PTCA Post-Dilatation Catheter - Technical Information ™ 3.30 3.25 Balloon Diameter (mm) Cordis EMPIRA NC ™ x 3.20 x 3.15 3.10 x 3.05 3.00 x 2.95 x x x x x x x x 8 10 0.0344" Strain relief color Red Balloon material DURALYN® Flex Balloon Material, non-compliant Shaft diameters Proximal 1.9F / distal 2.7F Shaft length 139 cm Minimum guiding catheter 5F Maximum guidewire .014" Nominal/Rated burst pressure (RBP) 14/20 atm x 2.90 Primary crossing profile* 12 14 16 18 20 22 24 Pressure (atm) ¼ size pressure Deliverability 3.0 mm balloon at 26 atm pressure reaches 3.261 mm in diameter Kissing balloon technique (KBT) compatible with Cordis 6F Guiding Catheters1 *Measured across the distal markerband of a 3.00 x 20 EMPIRA™ NC RX PTCA Post-Dilatation Catheter EMPIRA™ NC RX PTCA Post-Dilatation Catheter - Ordering Codes High pressures combined with low longitudinal growth Balloon Diameter (mm) 14 atm RBP: 20 atm Balloon Length (mm) 6 10 12 20 25 30 2.00 75R06200N75R10200N 75R12200N75R15200N75R20200N 2.25 2.50 75R06250N75R10250N 75R12250N75R15250N75R20250N75R25250N75R30250N 2.75 3.00 75R06300N75R10300N 75R12300N75R15300N75R20300N75R25300N75R30300N 3.25 3.50 75R06350N75R10350N 75R12350N75R15350N75R20350N75R25350N75R30350N 3.75 75R10375N 75R12375N 75R15375N75R20375N 4.00 75R10400N 75R12400N 75R15400N75R20400N 75R10225N 75R12225N 75R15225N75R20225N 75R10275N 75R12275N 75R15275N75R20275N Durability 75R10325N 75R12325N 75R15325N75R20325N EMPIRA™ NC 3.00 x 20 • Limited dog boning ensures uniform pressure through entire length of the balloon for optimal stent deployment1 15 References: 1. Cordis data on file, 2010 and 2011. 2. All data from manufacturer's product labels for 3.0 x 20 mm balloon sizes. Important Information: Prior to use, refer to the Instructions for Use supplied with these devices for indications, contraindications, side effects, suggested procedure, warnings and precautions. As part of the Cordis policy of continuous product development, we reserve the right to change product specifications without prior notification. Third-party trademarks are the trademarks of their respective owners. © CORDIS® Europe, a division of Johnson & Johnson Medical N.V. 2011 Tel: +32 2 746 3000 Fax: +32 2 746 3405 2E-800-1990-2 January 2012 PRODUCT CODE LEGEND 75R06200N Non-Compliant Diameter Length Rapid Exchange Product Control the Intervention with EMPIRA™ NC Cordis EMPIRA NC ™ RX PTCA Post-Dilatation Catheter EMPIRA™ NC Balloon Catheter features a low crossing profile1*† •Crossability: Proprietary folding & pleating reduce the primary profile, helping you reach even hard-to-treat lesions1 •Recrossability: Innovative hydrophilic coating improves lubricity & durability through multiple crosses •Flexibility: Next-generation DURALYN® Flex Balloon Material & kinkresistant shaft improve crossability & trackability •Best-in-class controlled growth: Perform intervention with the most non-compliant post-dilatation balloon available1 Next-generation DURALYN® Flex Balloon Material is 50% more flexible than DURALYN®1 Balloon Material 0.038 0.9652 0.037 0.9398 0.036 0.9144 0.035 0.889 0.034 0.8636 0.033 0.8382 0.032 Outer Diameter (OD) growth percentage 9 6 Percent Treat a wide range of complex lesions & help optimize stent deployment with: Inches EMPIRA™ NC Balloon Catheter: Designed to deliver in challenging interventions & post-dilatation procedures EMPIRA™ NC Balloon Catheter: Best-in-class controlled growth Millimeters Efficient & Effective 3 0.8128 EMPIRA™ NC Quantum™ Maverick® Monorail® Hiryu® DURA STAR® Voyager™ NC RX 0 EMPIRA™ NC DURA STAR® Voyager™ NC RX *All balloons reach P<0.05 vs EMPIRA™ NC Rx PTCA Post-Dilatation Catheter. †Balloon dimensions were the same for all products tested (measured across distal marker band of 3.00 mm x 20 mm). Quantum™ Maverick ® Monorail All balloons reach P<0.05 vs EMPIRA™ NC. a Growth percentage = (OD at rated burst pressure - OD at nominal burst pressure)/ OD at nominal burst pressure x 100. b Efficient access to complex lesions • Next-generation DURALYN® Flex Balloon Material offers 50% improved flexibility over DURALYN® Flex Balloon Material for better crossability1 • Hydrophilic coating is both lubricious & durable • Proprietary folding & pleating lowers primary profile1 • PTFE-coated, kink-resistant hypotube shaft • Best-in-class controlled growth – 3.09% between nominal and rated burst pressures (RBP)1‡ Nominal and Rated Burst Pressures2 atm 9 10 11 12 13 14 Controlled Growth EMPIRA™ NC Ease of use • Red color-coded strain relief for quick product identification • Clear hub for easy spotting of bubbles or fluid in the lumen Hiryu® Short Inflation / Deflation Times Effective design provides short inflation/deflation times1 NC Trek Voyager™ NC NC Quantum Apex™ Quantum™ Maverick™ Hiryu™ NC Sprinter™ ‡ Measured for a 3.00 x 20 EMPIRA™ NC RX PTCA Post-Dilatation Catheter Tested on 3.00 x 20 EMPIRA™ NC RX PTCA Post-Dilatation Catheter ‡‡ • HIgh rated burst pressure – 20 atm for all sizes • Mean Burst Pressure of 28.14 atm‡‡1 15 16 17 18 19 20