EMPIRA NC RX PTCA POST DILATATION CATHETER

advertisement
Cordis EMPIRA NC
™
RX PTCA Post-Dilatation Catheter
EMPIRA™ NC Balloon Catheter: Best-in-class controlled growth
EMPIRA™ NC Balloon Catheter delivers crossability &
best-in-class controlled growth to a wide range of lesions
EMPIRA™ NC: More Non-Compliant than other PTCA Balloons2
EMPIRA™ NC: The most Non-Compliant Balloon Compliance Curve
EMPIRA™ NC
Quantum™ Maverick™
NC Quantum Apex™
x
NC Trek
NC Sprinter™
Hiryu™
RX PTCA Post-Dilatation Catheter
EMPIRA NC RX PTCA Post-Dilatation Catheter - Technical Information
™
3.30
3.25
Balloon Diameter (mm)
Cordis EMPIRA NC
™
x
3.20
x
3.15
3.10
x
3.05
3.00
x
2.95
x
x
x
x
x
x
x
x
8
10
0.0344"
Strain relief color
Red
Balloon material
DURALYN® Flex Balloon Material, non-compliant
Shaft diameters
Proximal 1.9F / distal 2.7F
Shaft length
139 cm
Minimum guiding catheter
5F
Maximum guidewire
.014"
Nominal/Rated burst pressure (RBP) 14/20 atm
x
2.90
Primary crossing profile*
12
14
16
18
20
22
24
Pressure (atm)
¼ size pressure
Deliverability
3.0 mm balloon at 26 atm pressure reaches 3.261 mm in diameter
Kissing balloon technique (KBT) compatible with Cordis 6F Guiding Catheters1
*Measured across the distal markerband of a 3.00 x 20 EMPIRA™ NC RX PTCA Post-Dilatation Catheter
EMPIRA™ NC RX PTCA Post-Dilatation Catheter - Ordering Codes
High pressures combined with low longitudinal growth
Balloon
Diameter
(mm)
14 atm
RBP: 20 atm
Balloon Length (mm)
6
10
12
20
25
30
2.00
75R06200N75R10200N 75R12200N75R15200N75R20200N
2.25
2.50
75R06250N75R10250N 75R12250N75R15250N75R20250N75R25250N75R30250N
2.75
3.00
75R06300N75R10300N 75R12300N75R15300N75R20300N75R25300N75R30300N
3.25
3.50
75R06350N75R10350N 75R12350N75R15350N75R20350N75R25350N75R30350N
3.75
75R10375N 75R12375N 75R15375N75R20375N
4.00
75R10400N 75R12400N 75R15400N75R20400N
75R10225N 75R12225N 75R15225N75R20225N
75R10275N 75R12275N 75R15275N75R20275N
Durability
75R10325N 75R12325N 75R15325N75R20325N
EMPIRA™ NC 3.00 x 20
• Limited dog boning ensures uniform pressure through entire length of the balloon
for optimal stent deployment1
15
References:
1. Cordis data on file, 2010 and 2011.
2. All data from manufacturer's product labels for 3.0 x 20 mm balloon sizes.
Important Information:
Prior to use, refer to the Instructions for Use supplied with these devices for indications,
contraindications, side effects, suggested procedure, warnings and precautions. As part of
the Cordis policy of continuous product development, we reserve the right to change product
specifications without prior notification. Third-party trademarks are the trademarks of their
respective owners.
© CORDIS® Europe, a division of Johnson & Johnson Medical N.V. 2011
Tel: +32 2 746 3000
Fax: +32 2 746 3405
2E-800-1990-2 January 2012
PRODUCT CODE LEGEND
75R06200N
Non-Compliant
Diameter
Length
Rapid Exchange
Product
Control the Intervention
with EMPIRA™ NC
Cordis EMPIRA NC
™
RX PTCA Post-Dilatation Catheter
EMPIRA™ NC Balloon Catheter features a low
crossing profile1*†
•Crossability: Proprietary folding & pleating reduce the primary profile,
helping you reach even hard-to-treat lesions1
•Recrossability: Innovative hydrophilic coating improves lubricity &
durability through multiple crosses
•Flexibility: Next-generation DURALYN® Flex Balloon Material & kinkresistant shaft improve crossability & trackability
•Best-in-class controlled growth: Perform intervention with the most
non-compliant post-dilatation balloon available1
Next-generation DURALYN® Flex Balloon
Material is 50% more flexible than
DURALYN®1 Balloon Material
0.038
0.9652
0.037
0.9398
0.036
0.9144
0.035
0.889
0.034
0.8636
0.033
0.8382
0.032
Outer Diameter (OD) growth percentage
9
6
Percent
Treat a wide range of complex lesions & help optimize stent
deployment with:
Inches
EMPIRA™ NC Balloon Catheter: Designed to deliver
in challenging interventions & post-dilatation procedures
EMPIRA™ NC Balloon Catheter: Best-in-class controlled growth
Millimeters
Efficient & Effective
3
0.8128
EMPIRA™ NC
Quantum™
Maverick®
Monorail®
Hiryu®
DURA STAR®
Voyager™
NC RX
0
EMPIRA™ NC
DURA STAR®
Voyager™
NC RX
*All balloons reach P<0.05 vs EMPIRA™ NC Rx PTCA Post-Dilatation Catheter.
†Balloon dimensions were the same for all products tested (measured across distal marker band of 3.00 mm x 20 mm).
Quantum™
Maverick ®
Monorail
All balloons reach P<0.05 vs EMPIRA™ NC.
a
Growth percentage = (OD at rated burst pressure - OD at nominal burst pressure)/
OD at nominal burst pressure x 100.
b
Efficient access to complex lesions
• Next-generation DURALYN® Flex Balloon Material offers
50% improved flexibility over DURALYN® Flex Balloon
Material for better crossability1
• Hydrophilic coating is both lubricious & durable
• Proprietary folding & pleating lowers primary profile1
• PTFE-coated, kink-resistant hypotube shaft
• Best-in-class controlled growth – 3.09% between nominal and rated burst pressures (RBP)1‡
Nominal and Rated Burst Pressures2
atm
9
10
11
12
13
14
Controlled Growth
EMPIRA™ NC
Ease of use
• Red color-coded strain relief for quick
product identification
• Clear hub for easy spotting of bubbles
or fluid in the lumen
Hiryu®
Short Inflation / Deflation Times
Effective design provides short inflation/deflation times1
NC Trek
Voyager™ NC
NC Quantum Apex™
Quantum™ Maverick™
Hiryu™
NC Sprinter™
‡
Measured for a 3.00 x 20 EMPIRA™ NC RX PTCA Post-Dilatation Catheter
Tested on 3.00 x 20 EMPIRA™ NC RX PTCA Post-Dilatation Catheter
‡‡
• HIgh rated burst pressure – 20 atm for all sizes
• Mean Burst Pressure of 28.14 atm‡‡1
15
16
17
18
19
20
Download