INSTALLATION INSTRUCTIONS GRUVM-EX-GB 689-0424 LED, Gypsum Board pg 1 of 6 WARNING: RISK OF FIRE AND ELECTRICAL SHOCK. FIXTURE MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN ONLY. FIXTURE IS INTENDED FOR INSTALLATION IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE, LOCAL AND FEDERAL SPECIFICATIONS. DISCONNECT POWER AT ELECTRICAL PANEL BEFORE SERVICING. RETAIN THESE INSTRUCTIONS FOR MAINTENANCE REFERENCE. Suspension Points X 5” 5” X 5” X 10” 5” Example of a Continuous Row Individual Installation - (Individual fixture shipped as shown) 3” Mounting rods & hardware by others Suspension brackets supplied by Amerlux 5-7/16” Height @ supspension point Hanging the fixture via threaded rods. (Using Yoke) 1. Insert 1/4-20 bolt and secure with nut. (supplied by others) 2. Secure to structure via coupling. (supplied by others) 3. Remove 7/8” plug in top of housing at power feed location. Optional feed location thru KO in End Plate. 1. Hang the Fixture via wire and/or threaded rods. (Optional) Blocking as shown by others. 2. Once the fixture is secure, feed power source through the knock-out. Splice to harness according to code. 3. Install ceiling (by others).* 4. Spackle in fixture. 5. Remove Shipping Brace. 6. Snap in Lens. Fixture height 3-5/8” Support method by others Blocking support method (supplied by others) Ceiling contractor to spackle, feather & sand at ceiling interface. * Fixture MUST be mounted before ceiling is installed. 5/8” Shipping Brace 2-1/2” 5-1/4” MINIMUM CEILING OPENING MUST BE HELD BY INSTALLER FOR THE FULL LENGTH OF THE RUN DO NOT REMOVE SHIPPING SPACE UNTIL CEILING IS FINISHED. Snap-in lens Amerlux® LLC | 178 Bauer Drive, Oakland, NJ 07436 | p: 973-882-5010 f: 973-882-2605 | www.amerlux.com INSTALLATION INSTRUCTIONS GRUVM-EX-GB 689-0424 LED, Gypsum Board pg 2 of 6 Assembling Continuous Rows Note: With continuous rows, housing and reflector assemblies will ship separately. A. Housing Assembly Joining the Housings Line up the two housings by using the alignment splines. Secure them together by using the Catch and Latch System on the top of the extrusion. Catch and Latch Alignment Spline and/or Pins B. Reflector Assembly Installation 1. Insert the reflector by tilting it into housing. 2. Secure reflector to upper area of extrusion wia hex head screws. - For continuous runs, , connect each reflector assembly via quick connect plugs before installation. MAKE SURE TO DISCONNECT ALL ELECTRICAL CONNECTIONS BEFORE ACCESSING LED. WARNING: Electrostatic and polarity sensitive device. Use caution while handling and wiring. 1. LED Fixture: 2. LED Replacement: 3. Driver Maintenance: Consult Amerlux for LED maintenance. For LED board replacement reference 689-0394 Instruction Sheet. Drivers are located on Fixture Housing behind reflector. Remove the reflector mounting screws to access. Note driver resistance value during driver maintenance. Amerlux® LLC | 178 Bauer Drive, Oakland, NJ 07436 | p: 973-882-5010 f: 973-882-2605 | www.amerlux.com INSTALLATION INSTRUCTIONS GRUVM-EX-GB 689-0424 LED, Gypsum Board Wall Mounted (Horizontal/Vertical) pg 3 of 6 WARNING: RISK OF FIRE AND ELECTRICAL SHOCK. FIXTURE MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN ONLY. FIXTURE IS INTENDED FOR INSTALLATION IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE, LOCAL AND FEDERAL SPECIFICATIONS. DISCONNECT POWER AT ELECTRICAL PANEL BEFORE SERVICING. RETAIN THESE INSTRUCTIONS FOR MAINTENANCE REFERENCE. Suspension Points X 5” 5” X 5” X 10” 5” Example of a Continuous Row Individual Installation - (Individual fixture shipped as shown) Remove 7/8” plug in top of housing at power feed location. Optional feed location thru KO in End Plate. Blocking required (by others) 1. Install Blocking as shown by others. Secure housing to blocking using Selfdrilling screws (supplied by others) thru Fixture Flange 2. Once the fixture is secure, feed power source through the knock-out. Splice to harness according to code. 3. Install ceiling (by others).* 4. Spackle in fixture. 5. Remove Shipping Brace. 6. Snap in Lens. Fixture height 3-5/8” Support method by others Blocking support method (supplied by others) Ceiling contractor to spackle, feather & sand at ceiling interface. * Fixture MUST be mounted before ceiling is installed. 5/8” Shipping Brace 2-1/2” 5-1/4” MINIMUM CEILING OPENING MUST BE HELD BY INSTALLER FOR THE FULL LENGTH OF THE RUN DO NOT REMOVE SHIPPING SPACE UNTIL CEILING IS FINISHED. Snap-in lens Amerlux® LLC | 178 Bauer Drive, Oakland, NJ 07436 | p: 973-882-5010 f: 973-882-2605 | www.amerlux.com INSTALLATION INSTRUCTIONS GRUVM-EX-GB 689-0424 LED, Gypsum Board Wall/Ceiling Corner (L-Pattern) pg 4 of 6 WARNING: RISK OF FIRE AND ELECTRICAL SHOCK. FIXTURE MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN ONLY. FIXTURE IS INTENDED FOR INSTALLATION IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE, LOCAL AND FEDERAL SPECIFICATIONS. DISCONNECT POWER AT ELECTRICAL PANEL BEFORE SERVICING. RETAIN THESE INSTRUCTIONS FOR MAINTENANCE REFERENCE. Wall/Ceiling Corner Installation - “L” Pattern End Cover Side Covers Top (Sliding) Bracket (Closed Position) Vertical length Horizontal length Screws (4) Horizontal Fixture 1. Install Vertical fixture(s) from the ground up. Secure fixtures following instructions from page 1-3. 2. Once the fixture is secure, feed power source through the knock-out. Splice to harness according to code. 3. Install Horizontal fixture(s) closest to corner. A. Lift fixture to ceiling. Shift housing over vertical housing. (Overlap min. of 1/4”, max. of 2-1/2”) Reference layout drawing for location. Screws (4) Vertical Fixture B. Loosen the 4 side screws to the Top Bracket. Slide Top Bracket to wall & tighten the 4 side screws. C. (Optional) Secure vertical & horizontal brackets with self-drilling screw (by others). D. Remove End Covers & connect wire harness from the two fixtures. Install End Covers. E. Secure fixtures following instructions from pages 1-3. #8 x 3/8” Self-drilling screw (by others) 4. Install wall (by others).* 5. Spackle in fixture. 6. Remove Shipping Brace. 7. Snap in Lens. * Fixture MUST be mounted before wall/ceiling is installed. Amerlux® LLC | 178 Bauer Drive, Oakland, NJ 07436 | p: 973-882-5010 f: 973-882-2605 | www.amerlux.com INSTALLATION INSTRUCTIONS GRUVM-EX-GB 689-0424 LED, Gypsum Board Wall/Ceiling Corner (U-Pattern) pg 5 of 6 WARNING: RISK OF FIRE AND ELECTRICAL SHOCK. FIXTURE MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN ONLY. FIXTURE IS INTENDED FOR INSTALLATION IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE, LOCAL AND FEDERAL SPECIFICATIONS. DISCONNECT POWER AT ELECTRICAL PANEL BEFORE SERVICING. RETAIN THESE INSTRUCTIONS FOR MAINTENANCE REFERENCE. Wall/Ceiling Corner Installation - “U” Pattern Horizontal length Vertical length Vertical length Horizontal Fixture Top (Sliding) Bracket L-Pattern End Cover 1. Repeat steps 1-3 from L-Pattern Installation sheet on page 4. 2. Once the fixture is secure, feed power source through the knock-out. Splice to harness according to code. 3. Continue installing fixture closest to corner. 4. Loosen the 4 side screws to the Top Bracket. Slide Top Bracket to wall and tighten the 4 side screws. Screws (4) Side Covers (2) Screws (4) 5. Install Vertical fixture closest to the corner. A. Remove Side Covers. B. Mount fixtture so top edge of extrusion on the vertical fixture is flush with horizontal fixture. (Overlap min. of 1/4”, max. of 2-1/2”) Reference layout drawing for location. C. Remove End Covers and connect wire harness from the two fixtures. Install End Cover. E. Secure fixtures following instructions from pages 1-3. Vertical Fixture 6. Install wall (by others). * 7. Spackle in fixture. 8. Remove Shipping Brace. 9 Snap in Lens. ju Ad cco st A n rdi gly * Fixture MUST be mounted before wall/ceiling is installed. Amerlux® LLC | 178 Bauer Drive, Oakland, NJ 07436 | p: 973-882-5010 f: 973-882-2605 | www.amerlux.com INSTALLATION INSTRUCTIONS GRUVM-EX-GB 689-0424 LED, Gypsum Board pg 6 of 6 WARNING: RISK OF FIRE AND ELECTRICAL SHOCK. FIXTURE MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN ONLY. FIXTURE IS INTENDED FOR INSTALLATION IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE, LOCAL AND FEDERAL SPECIFICATIONS. DISCONNECT POWER AT ELECTRICAL PANEL BEFORE SERVICING. RETAIN THESE INSTRUCTIONS FOR MAINTENANCE REFERENCE. Additional Feed (if required) 1. Cut off harness connect. Harness Connector Hole Plug 2. Remove hole plug or knock-out. 3. Pass harness wires through feed hole. Feed Connector (by ohers) 4. Splice harness wires to feed conncetor wires using wirenuts (by others). 5. Install feed connector. Wirenuts (by others) Amerlux® LLC | 178 Bauer Drive, Oakland, NJ 07436 | p: 973-882-5010 f: 973-882-2605 | www.amerlux.com