ADVANCE GRP Series 125A Switched Interlocked socket outlets ADVANCE GRP Series 125A > SWITCHED INTERLOCKED SOCKET OUTLETS > REFERENCE STANDARDS EN 60309-1 Plugs, socket outlets and couples for industrial purposes. Part 1: general requirements. EN 60309-2 Plugs, socket outlets and couples for industrial purposes. Part 2: dimensional interchangeability requirements for pin and contact-tube accessories of harmonised configurations. EN 60309-4 Plugs, socket-outlets and couplers for industrial purposes. Part 4: Switched socket-outlets and connectors with or without interlock. > VERSIONS WITH MECHANICAL INTERLOCK With switch-disconnector IEC 61241-0 / EN 61241-0 Electrical apparatus for use in the presence of combustible dust. Part 0: General requirements. With switch-disconnector and fuse IEC 61241-1 / EN 61241-1 Electrical apparatus for use in the presence of combustible dust. Part 1: Protection by enclosures 'tD'. With fuse and switch > PRODUCTS FOR USE IN A POTENTIALY EXPLOSIVE ENVIRONMENT With molded case circuit breaker with thermal magnetic trip unit With molded case circuit breaker with thermal magnetic and residual current release trip units > VERSIONS WITH ELECTRICAL INTERLOCK With contactor 2 Scame offers products suitable for installation into environments under potential risk of explosion identified as Zone 22 and that enter into the field of application for the ATEX Directive (European Directive 94/9/CE). Saline solution Resistant Bases Acids Solvents Concentrated Diluted Concentrated Diluted Hexane Benzol Acetone Alcohol Limited Resistance Resistant Not Resistant Resistant Limited Resistance Limited Resistance Limited Resistance Limited Resistance Mineral oil UV rays Resistant Resistant ADVANCE GRP Series 125A > BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS For specific substances please contact our technical service > TECHNICAL CHARACTERISTICS Rated current: Rated voltage: Frequency: Insulating voltage: Protection degree: Operating temperature according to the reference standard: Max. operating temperature: Self-extinguishing GW test: Self-extinguishing UL94: Material: IK degree at 20°C: Cable inlets: 125A 100÷690V~ 50÷60Hz 500/690V~ IP66 -25°C+40°C 60°C 850°C/960°C V0 Thermoset IK10 Top side max 3xM63 Bottom side max 2xM63 Switch-disconnectors: ABB OT 160 Fuse: NH00 Thermal magnetic protection: Molded case circuit breaker ABB Tmax T1B (16kA) with thermal magnetic trip unit TMD (adjustable thermal threshold 0,7…1 x In fixed magnetic threshold 10 x In) Thermal-magnetic and Molded case circuit breaker residual current protection: ABB Tmax T1B (16kA) with thermal magnetic trip unit TMD (adjustable thermal threshold 0,7…1 x In fixed magnetic threshold 10 x In) + residual current release trip units RC221/1 (adjustable residual current trip 0,03 - 0,1 - 3A and time limit for non-trip instantaneous) Version with contactor: Contactor CL09 GE POWER CONTROL Colour: Grey RAL7037 > EX CLASSIFICATION Atex Code: II 3D Ex Protection type: Ex tD A22 IP66 T90°C Operating Temperature Range: -25°C +60°C Maximum permissible surface temperature: T90°C Switched socket outlets with interlock degree of Protection: IP66 Plugs - degree of Protection: IP66/IP67 Impact Resistance: 7J Switched socket outlets with interlock material: Thermoset Plugs material: Thermoplastic Interlocked switch sockets outlets CE certificate: SCAME ATEX 02 Plugs CE certificate: SCAME ATEX 03 Via Costa Erta 15 Parre BG ITALY 3P+N+ - 125A - 6h / 346-415V~ Cod. 503.12587-F SCAME ATEX 02 Ex tD A22 IP66 T90°C II 3D DO NOT OPEN WHEN ENERGIZED IN PRESENCE OF EXPLOSIVE ATMOSPHERE > WIRING OPERATIONS Wiring capacity of the terminals (mm2) Socket outlets Plugs Rated current (A) Min Max Min Max 125A 25 70 16 50 3 ADVANCE GRP Series 125A > APPLICATION EXAMPLES 4 ADVANCE GRP Series 125A > TECHNICAL DATA SWITCH DISCONNECTORS 125A Vac 750 Vdc 750 Rated impulse withstand voltage Uimp kV 12 Thermal current Ith A 200 Thermal current Ithe A - 400V A 200 500V A - 690V A 160 400V A 200 500V A - 690V A 160 400V A 135 500V A 125 690V A 80 400V A - 690V A - 300V A 160(*) 250V A 160(*) 600V A - A 4000 kA 24 kA 30 kA 1200 600V A 125 120V Hp 7,5 240V Hp 20 240V 480V 600V Hp Hp Hp 40 75 100 Rated insulation voltage Ui AC21A Resistite loads, inluding moderate overloads Nominal current rating Ie Mixed resistite and inductive loads, AC22A including moderate overloads Switching off motor loads or other AC23A highly inductive loads (3 phase/3 pole) AC3 Squirrel-cage motor: starting, switching off motor during running (3 phase/ 3 pole) DC21A Resistite loads, including Moderate overloads DC22A Mixed resistite and inductive loads, including moderate overloads Short-circuit protection Rated short-time withstand current Icw (s) Conditional short-circuit current Associate fuse size for conditional short-circuit current - Type gG Rated short-circuit making capacity Icm Rated current UL General applications - Single-phase and Three-phase AC motor, all-pole interruption - Single-phase AC motor, B, C, D, all-pole interruption - Three-phase Permissible wire range 500V mm2 10-70 AWG 8-1/10 Wire (*) 2+2 poles in series 5 ADVANCE GRP Series 125A Outdoor wall fastening Ample space for easy wiring Under-plate cable runway Switchdisconnector with mechanical lock that can be accessorized with auxiliary contacts Threaded metal inserts Punched marks for easy closure of the cover Easily extractable bottom plate Possibility to assemble microswitch BOTTOM VIEW TOP VIEW Module in hightemperature glassfibre filled engineering polymer Possible entry from bottom side (input-output also) 6 Self-centering punch marks to facilitate drilling ADVANCE GRP Series 125A Single-piece waterproof gasket Rating on metal plate Captive stainless steel closing screws Lockable Switch in position 0 and 1 High-strength material with superior UV and chemical resistance Double mechanical lock and metal levers Residual current release trip units test push button Cover entirely separate from the base for easy installation An electronic device controls the status of the interlocked socket, monitoring the electrical functionality: - operation of the signalling and control card is guaranteed even when the load is not connected; - indicates that the fuses are not open and all the phases are present (indicator light on); - indicates that the socket outlet is powered correctly (indicator light on); - signals the interruption of one or more fuses (indicator light flashing); - signals the absence of a phase (indicator light flashing)*; - indicates that the socket outlet is not powered (indicator light off). * for single-phase products in the event of phase/ neutral loss LED signaling appears off. 7 ADVANCE GRP Series 125A > MECHANICALLY INTERLOCKED SOCKET OUTLETS - IP66 Description Switchdisconnector Description Switchdisconnector and fuse (*) Description Fuse (*) and switch Description Plug Volt 2P+E 125A 50/60 200-250V 6 1 503.12583 3P+E 125A 50/60 380-415V 6 1 503.12586 3P+N+E 125A 50/60 346-415V 6 1 503.12587 Hz Volt 2P+E 125A 50/60 200-205V 6 1 503.12583-F 3P+E 125A 50/60 380-415V 6 1 503.12586-F 3P+N+E 125A 50/60 346-415V 6 1 503.12587-F Plug 2P+E 125A 50/60 200-205V 6 1 503.12583-FS 3P+E 125A 50/60 380-415V 6 1 503.12586-FS 3P+N+E 125A 50/60 346-415V 6 1 503.12587-FS Plug Hz Plug Hz (*) Fuses not included Volt Colour h Volt Molded case 2P+E 125A 50/60 circuit breaker with thermal magnetic 3P+E 125A 50/60 and residual current release trip units 3P+N+E 125A 50/60 8 Colour Hz Plug Molded case 2P+E 125A 50/60 circuit breaker 3P+E 125A 50/60 with thermal magnetic trip unit 3P+N+E 125A 50/60 Description Colour h Hz Colour h h 200-205V 6 1 503.12583-M 380-415V 6 1 503.12586-M 346-415V 6 1 503.12587-M Volt Colour h 200-205V 6 1 503.12583-RM 380-415V 6 1 503.12586-RM 346-415V 6 1 503.12587-RM Pack Quantity. Description Contactor (*) Hz Volt 2P+E 125A 50/60 200-205V 6 1 503.12583-T 3P+E 125A 50/60 380-415V 6 1 503.12586-T 3P+N+E 125A 50/60 346-415V 6 1 503.12587-T Plug Colour ADVANCE GRP Series 125A > ELECTRICALLY INTERLOCKED SOCKET OUTLETS - IP66 h (*) Microswitch already provided. Contactor operated by microswitch. > ACCESSORIES Description Terminals Contacts Microswitch kit 400V 10A 1NO+1NC (microswitch + terminal block) 4x4 mm2 579.0125 For products with mechanical interlock. > COMPLEMENTARY PRODUCTS - OPTIMA-EX SERIES - PLUGS IP66/IP67 Description Plugs Plug Hz Volt Colour h 2P+E 125A 50/60 200-250V 6 1 218.EX12533 3P+E 125A 50/60 380-415V 6 1 218.EX12536 3P+N+E 125A 50/60 346-415V 6 1 218.EX12537 9 ADVANCE GRP Series 125A > DIMENSIONS (Dimensions in mm) 10 Switch-disconnector and fuse Fuse and switch Molded case circuit breaker with thermal magnetic trip unit Molded case circuit breaker with thermal magnetic and residual current release trip units Contactor ADVANCE GRP Series 125A Switch-disconnector (Dimensions in mm) 11 ZP00738-GB-2 ScameOnLine www.scame.com export@scame.com SCAME PARRE S.p.A. VIA COSTA ERTA, 15 24020 PARRE (BG) ITALY TEL. +39 035 705000 FAX +39 035 703122