Hongdian Corporation H7210 fast user guide Website: www.hongdian.com Copyright 2004 Notice: Copyright The contents of the manual are protected by Chinese law, any organization and/or person can not copy this manual or part of contents without Shenzhen Hongdian Technologies Co., Ltd. authorization in written. Trademark 宏电 、 、Hongdian, GPRS DTU, CDMA DTU, MDTU, Wireless DDN, Hongdian, Hongdian Technologies and Shenzhen Hongdian are the logos and trademarks of Shenzhen Hongdian Technologies Co., Ltd. The other company trademarks and logos in this manual are owned by the owner, Hongdian does not have the right for those trademarks and logos. Hongdian Contents CHAPTER 1 INSTALLATION ..................................................................................... 3 2.1 GENERAL ..................................................................................................................... 3 2.2 INSTALLATION AND CABLE CONNECTION ...................................................... 3 2.4 GROUNDING ................................................................................................................ 7 2.5 POWER SUPPLY ......................................................................................................... 7 2.6 CHECK THE MOBILE NETWORK.......................................................................... 7 CHAPTER 2 DTU SETUP ............................................................................................. 8 3.1 SETUP CONNECTION ................................................................................................ 8 3.2 INITIAL CONFIGURATION ...................................................................................... 8 3.3 DTU CONFIGURATION (C) .................................................................................... 10 CHAPTER 3 AT EXPAND MODE ............................................................................. 13 APPENDIX: HYPERTERMINAL SETTING ................................................................ 13 Chapter 1 Installation 2.1 General Attention: Do not install H7210 GPRS/CDMA DTU or connect/disconnect its cable when it is power on. 2.2 Installation and Cable Connection Measurement H7210 DTU outside measurement and installation position: M80-721001-01 3 SIM Open top SIM/UIM protection cover, and then insert SIM or UIM from left-top side. SIM/UIM card conductors should face downside and the gap face to outside. The SIM/UIM card also need to be inserted properly and then cove back the SIM/UIM protection cover in order to prevent the SIM card from dropping out during shipping. Slide the SIM card by your finger to take out the SIM/UIM card. Voice Antenna SIM/UIM Ground Cascading/Config. Attention: H7210 DTU will not work and display “can not find SIM card” if you do not insert the SIM card to the end position. In order to prevent this problem, please put back the SIM cover after you insert the SIM card, and screw it tight. User Data and Power Cable Installation M80-721001-01 4 H7210 DTU signals and power supply is connected by industrial class pluggable terminals, 3.5mm, 12Pin, and 14~24AWG outlet cable is recommended. Each line definition refers to the following diagrams and tables. Also, you can find outlet cable definition table at top of H7210 DTU cover. As shown in the following diagrams and tables, peel off the cable end about 7mm () and connect each terminal and cable (14~24AWG cable recommended. Make sure that you have connected the terminals without any mistake. 7mm 14~24AWG Attention: The power cable should be connected correctly. We suggest double check before switch it on. Wrong connections may destroy the equipment. Power terminals: Pin 11 and Pin 12; Here: Pin 11 is “GND”, Pin 12 is power input “Vin” (+7.5~+26VDC). RS-232 signal definition Pin Signal Description 1 DCD Carrier Detection 2 RX Receive Data 3 TX Transmit Data 4 GPI General Purpose Input 5 OFF Power Off Control 6 GPO General Purpose output M80-721001-01 Note 5 7 8 9 10 11 12 RTS CTS RING GND GND Vin Request to Send Clear to Send Ring Signal Ground Ground +7.5~26V DC Input Current: 350mA@12V RS-232 interface complies the standard RS-232 specification. H7210F DTU RS-422 interface and power supply illustration: H7710F DTU RS-422 (User Side) DCD 1 R- 2 R+ 3 GPI 4 OFF 5 GPO 6 T- 7 T+ 8 RING 9 GND 10 GND 11 +Vin 12 2 R3 R+ 7 T8 T+ 9 RING 5 GND +Vin GND H7210S DTU RS-485 interface and power supply illustration: H7710S DTU DCD B(-) A(+) GPI OFF GPO RING GND GND +Vin RS-485 (User Side) 1 2 3 4 5 6 7 8 9 10 11 12 2 B(-) 3 A(+) 9 RING 5 GND +Vin GND RS-422/485 signal definition Pin Signal Description 1 2 T+/A(+) Transmit Data 3 T-/B(-) Transmit Data 4 GPI General Purpose Input 5 OFF Power Off Control M80-721001-01 Note A(+): RS-485 TX/RX B(-): RS-485 TX/RX 6 6 7 8 9 10 11 12 GPO RR+ RING GND GND Vin General Purpose Output Receive Data Receive Data Ring Signal Ground Ground +7.5~26V DC Input Only RS-422 Only RS-422 Current: 350mA@12V 2.4 Grounding To ensure a safe, stable and reliable H7210 DTU operation, DTU cabinet should be grounded properly. Connect the H7210 DTU cabinet to site ground wire at the ground point (refer to page 9 picture). 2.5 Power Supply H7210 DTU is designed with advanced power management technologies; it can operate standalone. The DC power is supplied via pluggable terminal Pin 11 (GND) and Pin 12 (Vin). Detail definitions refer to above tables. About Power Supply: When H7210 GPRS DTU communicates with base station, surge current will exceed normal current. Therefore, margins 5 times over normal current may be required for external power supply. Normally, H7210 DTU input power supply is +5~26VDC, in most cases, 12VDC/1A is recommended. Power input of +5VDC can be ordered for specified application. Power supply ripple should be less 300 mV. 2.6 Check the Mobile Network Connect all signal and power cables, and double check it, connect antenna, insert a valid SIM or UIM (depends your DTU type and network) and switch on power. H7210 DTU “PWR” LED will light up. If “PWR” LED is flashing, it means the H7210 DTU is working normally. If the “DATA” LED is flashing, it means there are data stream input/out over H7210 DTU data port. If the “NET” LED lights up, it means that the H7210 DTU has found and logged on mobile network. Antenna should be connected before switch on, otherwise it may cause radio module problem. M80-721001-01 7 Chapter 2 DTU Setup Please ask our technical support engineer for management tool. 3.1 Setup Connection H7210 DTU should be configured properly before putting into service. You can configure and manage DTU parameters by connecting DTU to your serial port of your PC via a configuration cable (you may need a RS485/232 convertor). or H7071 Config. Cable H7710 DTU Serial Port AC Adapter 3.2 Initial Configuration The default serial port Rate: Bits: Parity: Stop Bits Flow Control: setting of DTU: 57600baud 8bit None 1bit None Make sure the serial port is available then run the |Management Tools|, follow page will shows: M80-721001-01 8 a. Enter configuration: Keep this default setting and default password: admin b. Connect DTU data cable to your PC first, but do not connect power cable. Then click connect icon. c. Connect DTU power cable before timeout, default timeout is 50 seconds. If connection succeed, follow page will shows: M80-721001-01 9 Notice: 1. No matter you changed DTU serial port connection (RTU connection) parameters or not, you do not need change the baud rate in this tool, DTU still could connect. So in case you forget DTU parameters, you may use this tool to re-config DTU. 2. If you changed DTU password, you should change tool password before connection. 3.3 DTU Configuration (C) After connection DTU succeed. Common Parameters: set your own common parameters, make the config easily. If you are not familiar with DTU products, you may ignore this option. Query: inquire all DTU parameters. Config: tick one parameter first, then you could config it, after config done, click this icon to save setting into DTU. Default: retrieve all parameter to default. Reset: Reset DTU. Some parameters need you input value, some could only chosen from preset value, check its description for reference. In a typical application, your PLC/RTU connect to DTU and regularly upload data to your server. You need define follow parameters: 3.3.1 Cellular parameters M80-721001-01 10 This part defines all the cellular parameters. Please config it according to your local operator settings. This part of setting decides whether your DTU could connect internet. 3.3.2 RTU connection parameters This part defines the serial port parameters, and you should set it according to your RTU/PLC serial port setting. This part decides whether your RTU/PLC could communicate with DTU, if you use a PC to simulate and system works ok, but RTU/PLC do not work, usually you need adjust this part. 3.3.3 Channel parameters DTU default support 4 channel, means it could send RTU/PLC data to 4 different server at same time, you could set their parameters separately. If you only use one server to receive data, do not set other channels, otherwise you may lost extra flow fee. M80-721001-01 11 a. Protocol to DSC: protocol DTU used to communicate with DSC, usually be TCP or UDP. Please set it according to server end setting. b. DSC IP: your server IP address, this IP should be public or a internal IP which in a same private network with DTU. c. DSC port: DTU will send data to this port, and server will listening to this port. Please set it big then 5000 because in most of the county, port less than 5000 has been blocked. d. DSC domain: you could use domain instead of IP, this value only available when DSC IP set as 0.0.0.0 e. DTU local port: DTU communication port with PLC/RTU, cannot same as DSC port. f. Heart beat packet interval: heart beat used to keep DTU always on line, DTU will regularly send data to operator server, not your server to keep internet link available. If your RTU/PLC will send data in a short interval, you could disable this function. g. Define register packet: when enable DDP protocol, you could define register packet. Please do not change other options without suggest of technical support. About DDP protocol, a private protocol developed to enhance stability of communication during GPRS network, similar to TCP, so when used TCP, no need to use this protocol. And when enable this protocol, DTU is not a transparent communication, you need also enable DDP protocol on server end. 3.3.4 Others Other parameters should remain default. You could edit common parameters to easier the next setting process. When finished setting, save them and reboot DTU, If not entering config mode, DTU will auto-running and working, no need manual intervention. M80-721001-01 12 Chapter 3 AT expand mode When DTU is working, PC/PLC/RTU could input “+++” to enter AT expand mode, in this mode you could use AT-like command to config DTU. Appendix: HyperTerminal Setting This annex introduce the Microsoft Windows operating system HyperTerminal setting for the H7210 DTU configuration. 1. 2. 3. 4. COM Port Setting Properties Host System Encoding Method ASCII Setting 1. COM Port Setting By Clicking Windows “Accessories”->”Communications”->”HyperTerminal” to create a HyperTerminal. Refer to below picture to continue the settings. M80-721001-01 13 The COM port parameters should be specified. Select COM number (i.e. COM2), Bites per second, Data bits, Parity, Stop bits and Flow control. Notice: “Flow control” should be set to “None”. M80-721001-01 14 2. Properties Start the created H7000 HyperTerminal connection. Click “File”->“Properties” menu, click “Settings” tab, set it as show as the picture. 3. Host System Encoding Method Click “Input Translation” button, set host system encoding method. M80-721001-01 15 4. ASCII Setup Click “ASCII Setup” button, set ASCII parameters. M80-721001-01 16