Isolated safety barrier TSFx02W-EX Series 12.5mm ultra-thin switch output isolated safety barrier FEATURES z Input, output are mutually isolated from each other z 12.5mm ultra-thin case z Isolation voltage (Intrinsically safe and no-intrinsically safe:2KVAC/60S) PART NUMBER SYSTEM TSFx02W-EX z Protect: power reverse protect z Operating temperature range:-25 ~ +71℃ z Excellent EMC performance z High reliability(MTBF>500,000 hours) Safety barrier mark Slim case Channel configurat ion Channel number Signal flow Signal style Isolation t ransducer TSFx02W-EX series ultra-thin switch output isolated safety barrier, the product can drive equipment in hazardous area by controlling the switch of power supply in safe area. Driving power is 12V/44mA. Products are suitable for drivers, such as solenoid valves, audible and visual alarm, and other intrinsically safe end equipment. The product’s shell is as thin as 12.5mm. Connection of field devices and the regions: switch; zone 0,zone 1,zone 2; IIA,IIB,IIC,T4~T6 hazardous area. Industries applications: intrinsically safe explosion protection systems of chemical engineering, petroleum, metallurgy, mining, pharmacy, natural gas, electric power, etc. Selection Guide Part No. Isolation voltage Description TSF102W-EX 2KVAC 1 input 1 output TSF202W-EX 2KVAC 2 input 2 output Input Specifications Item Operating Conditions Value Power supply Power Supply Input Safe Zone 18-30VDC (Typical value 24VDC) Input power When the output current is in its max. value About 2.4W Power supply protection Anti-reverse protection Input signal Dry contact input Output Specifications Item Operating Conditions Open status voltage Hazardous Zone Output voltage Value 24VDC±5% Current 44mA ≥12VDC Driving capability 12VDC/44mA Recovery time ≤5ms General Specifications & Explosion Protection Certification parameter Item Operating Conditions Value Electric Isolation 1Min, humidity < 70%, leakage current ≤1mA Intrinsically safe and no-intrinsically safe:2KVAC/60s Isolation Resistance Intrinsically safe and no-intrinsically safe:≥100MΩ,500VDC MTBF >50,0000 h Explosion Protection Certification Mark [Exia Ga]IIC Explosion Protection Certification Parameter Pin(6+,5-); Uo:26.3VDC Um:250VAC/DC Co:0.08uF (2+,1-) Io:130mA Po:0.85W Lo:1.5mH 2015.02.27-A/1 Page 1 of 4 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation Isolated safety barrier TSFx02W-EX Series CQST (China National Quality Supervision and Test Centre for Explosion Protected Electrical Products) Explosion Protection Certification Body Explosion Protection Certificate No. CNEx13.3056 Operating Temperature -25 ~ +71℃ Transportation and Storage Temperature -40~+85℃ Physical Specifications Casing Material Retardant material UL94-V0 Protection Class IP20 (IEC60529 / EN60529) Dimension 35mm DIN-rail package:T-rail card package (DIN50022), pluggable connection terminal, 107.00mm*108.50mm*12.50mm. Weight 1 input 1 output about 100g, 2 input 2 output about 128g (Typ.) Cooling Method Free convection EMC Specifications EMS ESD IEC/EN61000-4-2 Contact ±4KV/Air ±8KV perf. Criteria B RS IEC/EN61000-4-3 10V/m perf. Criteria A IEC/EN61000-4-4 power supply port ±2KV perf. Criteria A IEC/EN61000-4-4 signal port ±1KV perf. Criteria A IEC/EN61000-4-5 power supply port ±1KV perf. Criteria B IEC/EN61000-4-5 signal port ±1KV (line-to-ground) perf. Criteria B IEC/EN61000-4-6 3 Vr.m.s perf. Criteria A EFT Surge CS Application Precautions 1. 2. 3. 4. Please read the instructions carefully before use; contact our technical directly if you have any problem; Do not use the product in hazardous zones; Use DC power supply for the product, and 220V AC power supply is prohibited; Do not disassemble or assemble the product without permission to avoid explosion protection failure or malfunction of product. Design Reference 1. Wiring diagram for product application 2 inpu t 2 o utpu t Safe A rea Hazar dous Ar ea + + 6 8 _ 5 _ 7 Power Electr omagn etism valv e/Alar m 2 12 _ 1 1 cha nnel 2 _ Power + + cha nnel 1 1 Note:This diagram is for 2 input & 2 output model only, 1 input & 1 output model connect channel 1 only. 2. Output typical curve Vo(VDC) 24 12 0 44 Io(mA) ① Use dismountable ports for instrument wiring, easy to operate; ② The sectional area of conductor is 0.5mm2-2.5 mm2; ③ The length of conductor exposed is 8mm and is fastened by M3 bolts. 2015.02.27-A/1 Page 2 of 4 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation Isolated safety barrier TSFx02W-EX Series 3. Application in the intrinsically safe explosion protection system In the intrinsically safe explosion protection system, the isolated safety barrier belongs to related equipment and is installed in a safe location for connecting the intrinsically safe equipment in hazardous location and non-intrinsically safe equipment in safe location, which is capable of limiting the energy entering into the site in safe value, so as to ensure the safety of site equipment, personnel and production. The selection principles for the safety barrier in the intrinsically safe explosion protection system: 1) The grade of the explosion-proof marker of safety barrier must be not less than that of the intrinsically safe site equipment. 2) The port resistor and loop resistance of safety barrier should be taken into consideration so as to ensure the output voltage of safety barrier can meet the requirements of the min. operating voltage of the intrinsically safe site equipment. 3) The safety parameters of the intrinsically safe port of safety barrier can meet: Uo ≤ UI, Io ≤ Iin, Po ≤ Pin Cc≤ Co-Ci, Lc ≤Lo-Li 4) Select the matched safety barrier according to the power supply polarity and signal type of intrinsically safe site equipment as well as its transmission mode. 5) The wires leading to the dangerous places should use the blue safety wire, wire soft copper area must be greater than 0.5mm2, dielectric strength should be greater than 500VDC. 4. For more information please find the application notes on www.mornsun-power.com Installation & disassembly Installation Disassembly DIN35mm standard rail installation 1. Insert the top of the instrument card in the rail; 2. Push the bottom of the instrument into the rail. 1. Insert to the clamp on the lower end of instrument with a screw driver (tool edge width≤6mm); 2. Push the screw driver up, and pry the clamp down; 3. Pull the instrument up out of the guide rail. 1 3 2 1 2 Dimensions 2015.02.27-A/1 Page 3 of 4 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation Isolated safety barrier TSFx02W-EX Series Notes: 1. Packing information please refer to Product Packing Information which can be downloaded from www.mornsun-power.com. Packing bag number: 58040010; 2. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25℃, humidity<75% with nominal input voltage and rated output load; 3. All index testing methods in this datasheet are based on our Company’s corporate standards; 4. The performance parameters of the product models listed in this manual are as above, but some parameters of non-standard model products may exceed the requirements mentioned above. Please contact our technicians directly for specific information; 5. We can provide product customization service; 6. Specifications are subject to changes without prior notice. Mornsun Guangzhou Science & Technology Co., Ltd. Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China Tel: 86-20-38601850-8801 Fax: 86-20-38601272 E-mail: info@mornsun.cn 2015.02.27-A/1 Page 4 of 4 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation