CSRT-XHE CSRN-XHE Packaged air-conditioning unit 122÷302 CLIVETPACK CSRT-XHE: cooling only 4 4CSRN-XHE: heat pump Air cooled Roof Top Capacity from 46,7 to 101 kW On Line Monitoring Service available PACKAGED CSRT-XHE/CSRN-XHE air conditioning units are fully independent roof-top units developed by CLIVET using the latest and most advanced air conditioning technology. They are extremely compact and weatherproof, and are available in various heating and cooling power ratings, and outdoor and total air flow rates to cover the widest possible range of installation needs. They also incorporate two-stage filtration, Free Cooling and automatic flow control of supply, return, extraction and outdoor air. In dual fan configurations, the thermodynamic heat recovery system installed in the extracted air flow remains active in both heating and cooling mode. These units are therefore particularly suitable whenever excellent air quality and efficient temperature and humidity control are needed to ensure personal wellbeing. The units are factory tested and supplied with all the necessary fittings, so that they can be started up as soon as they are connected to the electricity, air and water systems. Units can be controlled using the on-board keypad, a remote control keypad or can be interfaced with a BMS-type management system. functions and features AIR Cooling only (CSRT-XHE) Heating-Cooling (CSRN-XHE) Air cooled FC R-410A Roof Top Refrig. R-410A Herm. Scroll available configurations (1) CSRT-XHE C 162 (1) CONSTRUCTIONAL CONFIGURATION: 4B Fresh air mixing, recirculation/intake plenum 4C Radial expulsion fan, mixing chamber /re-circulation / external air intake with free-cooling adjustment. 120 Ice protection system Free-Cooling CC Thermodynamic Heat Recovery Direct Coupled Fan ECO BREEZE ECOBreeze EEV Electronic Expansion Valve accessories 4 4 4 4 4 4 4 4 4 4 4 4 4 Copper/copper condenser coil Copper/copper evaporator coil Hot gas post-heating coil Copper/copper hot gas post-heating coil Hot water coil with 2 rows 3-way modulating valve Droplet-separator humidifier with once-through water Immerse electrode steam humidifier Extra section of class F7 rigid bag filters Extra section of very high efficiency electronic filters H10 Air side dirty filters differential pressure switch Device for reducing consumption of the outdoor section fans of the ECOBreeze Device for operation at low outside temperatures with variable fan speed 4 4 4 4 4 4 4 4 4 4 4 4 4 Automatic constant flow control device Remote control with remote microprocessor control Remote keypad Modulating natural gas or LPG heating module with condensation Serial communication module RS485 Additional electric heaters High and low pressure gauges Enthalpy control (humidification, dehumidification, post-heating) Air quality control (CO2 and CO2+VOC) in relation to crowding Enthalpy Free-Cooling Rubber antivibration mounts Shunt capacitors (power factor > 0,9) Smoke detector Key to symbols: Accessories supplied separately. Sizes 4 Cooling capacity Sensible cooling capacity Compressor input 4 Heating capacity Compressor input Supply air flow rate Number and type of compressors Number and type of circulating fans Number and type of exhaust fans Max. working static pressure Sound pressure level Power supply (1) (1) (1) (2) (2) (3) (3) (4) (5) 122 46,7 33,2 11,46 45,3 8,54 2220 kW kW kW kW kW l/s Pa dB(A) V/Ph/Hz 162 53,5 39,1 13,0 53,2 10,37 2500 182 64,8 46,3 15,1 63,7 12,02 3060 222 73,7 52,2 18,6 73,5 14,11 3610 262 91,8 67,5 20,5 90,0 16,3 4440 PACKAGED technical data 302 101 72,8 24,0 98,7 18,3 5000 2 SCROLL 1 RAD 2 RAD 1 RAD 450 65 520 65 450 68 370 69 460 70 510 70 400/3/50 Data referred to the following conditions: None of the cooling capacities take account of the heat dissipated by the motors of the centrifugal fans; for units in constructional configuration "C" and operation with 30% of external and expelled air (1) Ambient air exchanger inlet air 27°C D.B. / 19,5°C W.B.; external air temperature 35°C; (2) Ambient air exchanger inlet air 20°C; external air 7°C D.B./ 6.1°C W.B; (3) RAD = radial-blade fan (4) Working static pressure does not consider accessories that cause air-side pressure drops (for exemple: additional sections of bag filters F7, hot water coil, post-heating coil, noise attenuators...) Sound levels refer units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. Working head 50 Pa (5) dimensions and functional spaces leave free C A2 B1 A B B2 CAUTION! Sizes Length (A) Width (B) Height (C) 4 (A2) (B1) (B2) CSRT-XHE Weight in oper. CSRN-XHE Weight in oper. mm mm mm mm mm mm 122 3320 1915 2110 2000 1500 1500 162 3320 1915 2110 2000 1500 1500 182 3320 2300 2130 2000 1500 1500 222 3320 2300 2130 2000 1500 1500 262 3570 2315 2260 2000 1500 1500 302 3570 2315 2260 2000 1500 1500 Kg 1135 1185 1380 1430 1625 1675 Kg 1160 1210 1415 1465 1655 1705 The above data refer to units in constructional configuration C. N.B. For all other constructional configurations, see the relevant Technical Bulletin. For trouble-free operation of the unit it is essential to maintain the safety distances indicated by the green areas. 121