12 Volt 2.0 AH PS-1221 This model has been discontinued. Specs are for reference only. Features • Absorbent Glass Mat (AGM) technology for superior performance • Valve regulated, spill proof construction allows safe operation in any position • Power/volume ratio yielding unrivaled energy density • Rugged impact resistant ABS case and cover (UL94-HB) • Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified • U.L. recognized under file number MH 20845 Terminals Performance Specifications (mm) Nominal Voltage ........................................................................ 12 volts (6 cells) • Pressure Contacts Positive Negative 6 6 10.5 Nominal Capacity 13.5 .5 .5 20-hr. (100mA to 10.50 volts) ........................................................ 2.00 AH 10-hr. (190mA to 10.50 volts) ....................................................... 1.90 AH 5-hr. (340mA to 10.20 volts) ....................................................... 1.70 AH 1-hr. (1.24A to 9.00 volts) ............................................................. 1.24 AH 15-min. (3.33A to 9.00 volts) .............................................................. 0.83 AH Approximate Weight ........................................................... 1.30 lbs. (0.59 kg) Physical Dimensions: in (mm) Energy Density (20-hr. rate) ............................... 1.77 W-h/in3 (108.10 W-h/l) Specific Energy (20-hr. rate) ............................. 18.46 W-h/lb (40.70 W-h/kg) Internal Resistance (approx.) ..... This battery is protected by a bimetal circuit breaker. If the current discharge temperature rises above design limits the breaker is activated W Max Discharge Current (7 Min.) .................................................. 6.0 amperes Max Short-Duration Discharge Current (10 Sec.) ....... n/a - battery is fused Shelf Life (% of nominal capacity at 68°F (20°C)) CAUTION Sealed Rechargeable Battery HT MODEL PS-1221 ® MH20845 M UST BE R Pb YCL ED "SEALED LEAD BATTERY. MUST BE RECYCLED OR DISPOSED OF PROPERLY." H EC 12 Volt 2.0 Amp. Hr. TTERY BA Do not make direct contact between battery terminals. Do not discharge completely. Recharge battery immediately after use. Do not use other than specified battery charger. Do not use below -10º C (15º F) or above + 40º C (105º F). Recharge battery immediately after use. If the temperature exceeds this upper limit, a safety device will automatically prevent operation of battery. 1 Month ...................................................................................................... 97% 3 Months ..................................................................................................... 91% NONSPILLABLE 6 Months .................................................................................................... 83% L Operating Temperature Range Charge .. .......................................................... 15°F (-10°C) to 105°F (40°C) L: 5.63 (143) W: 0.94 (24) H: 2.56 (65) HT: 2.56 (65) Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. Discharge ........................................................ 15°F (-10°C) to 105°F (40°C) Case ...................................................................................................... ABS Plastic Power-Sonic Chargers ................................................................... PSC-12300A To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website. All data subject to change without notice. www.power-sonic.com PS-1221 12 Volt 2.0 AH ® Discharge Characteristics 100 Charging is not necessary unless 100% of capacity is required. 80 Charging before use is necessary to help recover full capacity. 5oC (41oF) 60 o 30 C o (86 F) 40oC (104oF) 40 0 14.0 0 2 4 6 8 10 Charge may fail to restore full capacity. Do not let batteries reach this state. 20oC (68oF) 12 14 16 18 20 o 12.0 11.0 10.0 9.0 2.4 12 24 36 48 1 2 Discharge Time 4 6 8 10 20 4 0 h Life Characteristics in Stand-By Use 5 Retention Capacity (%) h 6 min 20 15 10 Discharge Time 2.0 4.0 1.2 Discharge Time vs. Discharge Current 0.20 0.10 0.40 1.0 Final Voltage 8.0 Standing Period (Months) o Ambient Temperature 20 C (68 F) 13.0 Terminal Voltage (V) Capacity Retention Ratio (%) Shelf Life & Storage Final Voltage 10.5V 2 10.2V 1 9.6V min 30 9.0V 10 5 o 8.1V 0.10 0.20 0.40 1.0 2.0 80 60 20 0 o Note: Due to the self-discharge characteristics of this type of battery, it is imperative that they be charged within 6 months of storage, otherwise permanent loss of capacity might occur as a result of sulfation. Chargers 1 2 3 4 Life Characteristics in Cyclic Use 120 Retention Capacity (%) Discharge Current (A) “Float” or “Stand-By” Service: Hold battery across constant voltage source of 13.5 to 13.8 volts continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. 0 Years 4.0 Cycle Applications: Limit initial current to 600mA. Charge until battery voltage (under charge) reaches 14.4 to 14.7 volts at 68°F (20°C). Hold at 14.4 to 14.7 volts until current drops to under 20mA. Battery is fully charged under these conditions, and charger should be disconnected or switched to “float” voltage. Float Charging Voltage 2.25 - 2.30 V/Cell 40 40 C (104 F) o o 20 C (68 F) o o 0 C (32 F) Charging Ambient Temperature 20˚C (68˚F) 100 100 80 60 Discharge Depth 100% Discharge Depth 50% Discharge Depth 30% 40 1. Discharge Current 0.2C (Final Voltage 1.7V/Cell) 2. Charge Current: 0.1C 3. Ambient Temperature: 20oC to 25oC (68oF to 77oF) 20 0 0 200 400 600 800 1000 1200 Number of Cycles Further Information Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH. Please refer to the Charger Selection Guide in our specification sheets for “C-Series Switch Mode Chargers” and “Transformer Type A and F Series”. Please contact our Technical department for advice if you have difficulty in locating suitable models. Please refer to our website www.power-sonic.com for a complete range of useful downloads, such as product catalogs, material safety data sheets (MSDS), ISO certification, etc.. Contact Information DOMESTIC SALES Tel: +1-619-661-2020 Fax: +1-619-661-3650 national-sales@power-sonic.com www.power-sonic.com CUSTOMER SERVICE Tel: +1-619-661-2030 Fax: +1-619-661-3648 customer-service@power-sonic.com TECHNICAL SUPPORT Tel: +1-619-661-2020 Fax: +1-619-661-3648 support@power-sonic.com INTERNATIONAL SALES Tel: +1-650-364-5001 Fax: +1-650-366-3662 international-sales@power-sonic.com CORPORATE OFFICE • 7550 Panasonic Way • San Diego, CA 92154 • USA • Tel: +1-619-661-2020 • Fax: +1-619-661-3650 © 2011. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners. 0211 1M