Single Phase Harmonic Filters Table of Contents 3rd Harmonic Filters Delivery / Lead Time PB-1400-2 Product Description PB-1400-3 Catalog Numbering System PB-1400-4 Selection Guide PB-1400-5 Pricing 3rd Harmonic Filters 3rd Harmonic Inductors Only PB-1400-6 PB-1400-6 PB-1400-7 Product Specification PB-1400-8 Product Characteristics PB-1400-10 Data subject to change without notice. Effective 01/18/10 PB-1400-1 TYPICAL DELIVERY SCHEDULE 3rd HARMONIC FILTER Panel Mounted Style All Filters Built to Order TYPE SHIPMENT 120V, 60 HZ Filter 1 - 3 Weeks 240V, 60 HZ Filter 2 - 4 Weeks 240V, 50 HZ Filter 2 - 4 Weeks Inductors Only 1 - 4 Weeks Data subject to change without notice. Effective 01/18/10 PB-1400-2 3rd HARMONIC FILTERS MTE 3rd Harmonic Filters are designed to be used on single phase branch circuits with a high number of triplen harmonic producing loads attached. The filter typically reduces triplen harmonics (3rd, 9th, 15th) caused by switch mode power supplies, electronic ballasts, light dimmer controls, and single phase motor drives. This filter reduces triplen harmonic currents in the neutral of the upstream three phase distribution system. Features • Open panel construction • Single phase • 5, 10, and 15 Amp versions • 120V 60 HZ, 240V 50 HZ or 60 HZ • Hardwired terminal block supplied • Typical 80 – 90% reduction in each individual harmonic from the 3rd through the 9th. • Reduce triplen harmonics in three phase neutrals. Data subject to change without notice. Effective 01/18/10 PB-1400-3 3rd Harmonic Filter Catalog Numbering System X X HF X X FREQUENCY BLANK = 60 HZ X = 50 HZ VOLTAGE BLANK = 120V 2 = 240V PRODUCT TYPE - HF ENCLOSURE TYPE P = OPEN PANEL FILTER RATING (Amps) Data subject to change without notice. Effective 01/18/10 PB-1400-4 Catalog Number Selection Procedure: 1. Identify the following a. Identify the maximum current draw of the device (5, 10, or 15 Amps). b. The enclosure type required. (P=Open unit in all cases.) c. Product type is HF in all cases. d. Line voltage (Blank=120V, 2=240V) e. Line frequency (Blank = 60 Hz, X = 50 Hz) 2. Create the part number a. Start with 5, 10, or 15 identified in item (1.a.) b. Append a “P”, the results of item (1.b) c. Append a “HF”, the results of (1.c) d. Append the results of (1.d) e. Append the results of (1.e) 3. Look up the created catalog number in the following tables to determine list price. (Note: The ‘X’ is a place holder and will be substituted with a ‘D’ or an ‘F’ in the tables depending on the series.) 4. Check with the factory if you can not find the part in the table. 5. For example a 10 AMP, 120V - 60 Hz unit’s part number would be: From 2.a From 2.b From 2.c From 2.d From 2.e 10 P HF Blank Blank Another example is a 5 AMP, 240V - 50 Hz unit’s part number would be: From 2.a From 2.b From 2.c From 2.d From 2.e 5 P HF 2 X The list price for the 10PHF and 5PHF2X can be found on the next page.. Data subject to change without notice. Effective 01/18/10 PB-1400-5 PRICE LIST 3rd Harmonic Filters OPEN PANEL Model Amps Volts 5PHF 5 120 10PHF 10 120 15PHF 15 120 5PHF2 5 240 10PHF2 10 240 15PHF2 15 240 5PHF2X 5 240 10PHF2X 10 240 15PHF2X 15 240 VA 600 1200 1800 1200 2400 3600 1200 2400 3600 Frequency (HZ) 60 60 60 60 60 60 50 50 50 Weight (LB) (KG) 6 2.2 7 2.6 12 4.5 6 2.2 7 2.6 12 4.5 6 2.2 7 2.6 12 4.5 Price $ 310 $ 379 $ 459 $ 310 $ 379 $ 459 $ 330 $ 395 $ 465 Includes inductor, capacitors, terminal block and panel only. Inductors only for 3rd Harmonic Filters 600 Volts max, 50/60 HZ Rating (Amps) 5 10 15 Cat. No. L-11614 L-11615 L-11616 Price $ 89 $ 102 $ 132 Data subject to change without notice. Effective 01/18/10 Weight (LB) (KG) 4 1.5 5 1.9 10 3.7 PB-1400-6 3rd Harmonic Filter Responsibility: Engineering Approved By: ISO Section: 7.3.3 SCOPE: ES-006 Rev 000 10/28/03 3rd Harmonic Filter Specification 1.0 General This 3rd Harmonic filter is intended to reduce triplen harmonics generated by voltage switching loads. 1.1 The 3rd Harmonic filter incorporates UL recognized inductor, capacitors, wires, and terminal block but is not UL component recognized as an assembly. 1.2 These filters reduce triplen (3rd and 9th ) current harmonics produced by personal computers, electronic ballasts, lighting dimmer controls, uninterruptible power supplies, or 1-Phase Motor Drives/Inverters., 1.3 The 3rd Harmonic Filters are used to reduce neutral currents, reduce transformer loading, protect electrical systems, reduce fire hazards, and improve power factor. 2.0 Electrical Ratings: 2.1 Filters can be selected for 120V – 60 Hz, 240V – 60Hz, and 240V – 50 Hz single phase supply sources with 5, 10, or 15 Amp ratings.. 3.0 Applicable Standards 3.1 CUL Recognized inductors, UL component categories NMTR2 and NMTR8 3.2 UL recognized capacitors, UL component category CYWT2. 3.3 UL recognized wiring, UL component category AVLV2 3.4 UL recognized terminal block, UL component category XCFR2 Data subject to change without notice. Effective 01/18/10 PB-1400-7 4.0 Standard Features 4.1 UL Recognized components only. Assembled filter is not UL recognized. 4.2 Open panel construction 4.3 Terminal block supplied for hard wiring. 4.4 Ground stud provided on the panel 5.0 Optional Features 5.1 5A, 10A, 15A 50/60 Hz, 600V, UL Recognized inductors sold stand-alone 6.0 Documentation 6.1 Typical dimensional data shall be supplied by MTE upon request. Data subject to change without notice. Effective 01/18/10 PB-1400-8 3rd Harmonic Filter Product Specification Open Panel Construction Inductors only for 3rd Harmonic Filters 600 Volts max, 50/60 HZ Cat. No. L-11614 L-11615 L-11616 L (mH) 9.77/8.8 4.89 4.89 Height (H) Width (W) (in.) (mm) (in.) (mm) 2.80 71 3.00 76 2.80 71 3.00 76 3.20 81 3.75 95 Depth (D) (in.) (mm) 3.50 89 3.69 94 5.09 129 Mounting Width (E) Depth (F) Weight (in.) (mm) (in.) (mm) (LB) (KG) 2.50 64 1.44 37 4 1.5 2.50 64 3.13 79 5 1.9 3.13 79 4.07 103 10 3.7 Note: L-11614 has three leads, Common (Red), 50 HZ (Yellow) , and 60 HZ (Blue) leads. L-11615 and L-11616 connect to the same two leads for 50 HZ or 60 Hz operation. Data subject to change without notice. Effective 01/18/10 PB-1400-9 PRICE LIST 3rd Harmonic Filter Product Specification Technical Data Data subject to change without notice. Effective 01/18/10 PB-1400-10 ISO 7.2.3 Responsibility: Approved by: File Location: Single Phase Harmonic Filters PB-1400 Corporate Karl Hink J:\Public\Controlled Documents\Sales\PRICE BOOK Revision --- Date 10/15/03 001 10/28/03 002 11/14/03 003 9/29/05 004 1/18/10 IMPORTANT! Revision History (recorded by date on document) New document written by Karl Hink Revised by Hank Nechvatal – ES-004 R--- 3rd Harmonic Filter was changed to ES-006 R--- 3rd Harmonic Filter Revised by Bruce Schram – Corrected Part number on PB-1400-15. ZDG036A was incorrectly indicated as ZDG063A. Rev WRW: price adjustments pages 6 and 15 effective 11/1/05. Rev WRW: price adjustments page 6 removed zero sequence and zigzag transformers products effective 1/18/10 Make sure ES-005 Zero Sequence Harmonic Filter and ES-006 3rd Harmonic Filter revisions agree with those in PB-1400. Data subject to change without notice. Effective 01/18/10 PB-1400-11