www.martekpower.com MW400S 400 Watts Output Power ACTIVE POWER FACTOR CORRECTION & ISOLATED DC OUTPUT MODULE HOW TO ORDER FEATURES 400 - S MW M / 28 - I Series I - M3 inserts Total Output Power(W) Single Output Unscreened (I) or Screened(M) Output Voltage INPUT CHARACTERISTICS Min. 90 Input Voltage (Single Phase) 47 Input Frequency Range 120 Input Voltage DC Inrush Current @115 Vrms @240 Vrms Input Filter Capacitance Power factor @ 400W Output Power 0.98 115Vin / 60Hz 0.94 115Vin / 400Hz 0.95 230Vin / 50Hz Efficiency at Full Load 28Vout, 115Vin / 60Hz 28Vout, 115Vin / 400Hz 28Vout, 230Vin / 50Hz 5Vout, 115Vin / 60Hz 5Vout, 115Vin / 400Hz 5Vout, 230Vin / 50Hz No Load Input Current No Load Input Power Input Power, Output Disabled Input Undervoltage Shutdown Input Undervoltage Hystersis Typ. Max. Units 265 Vac 440 Hz 380 Vdc 20 28 3.1 A A μF 0.99 0.95 0.97 81 80 82 78 77 80 .55 60 13 89 6 % % % % % % Arms W W Vac Vac • Meets Harmonic Requirements of MIL - STD - 1399 • Meets CE101 and CE102 of MIL - STD - 461 (No external filter required) • Meets MIL standards: MIL - STD - 704E and MIL - STD - 810 • Non-latching Over Temperature Protection • Latching Output Overvoltage Protection • Isolated Input AC Good TTL Signal • Isolated Output DC Good TTL Signal • Isolated 13 VDC Standby Output • Fully rated 400 Watts of output power from 90 VAC to 265 VAC and up to 100°C baseplate temperature • Utilizes non isolated boost topology followed by isolated DC-DC converter • Environmental Screening available • Fixed frequency PFC and DC-DC converters synchronized at 240/480 kHz or to a 500 - 550 kHz external clock • 385 VDC PFC High Voltage Bus is accessible at the input connector SELECTION CHART Nominal Output Voltage (Volts) 2 3.3 5 12 15 24 28 Output Current (Amps) 100 100 80 33.3 26.7 16.7 14.3 Model Number (Unscreened) MW400SI/2 MW400SI/3.3 MW400SI/5 MW400SI/12 MW400SI/15 MW400SI/24 MW400SI/28 Model Number (Screened) MW400SM/2 MW400SM/3.3 MW400SM/5 MW400SM/12 MW400SM/15 MW400SM/24 MW400SM/28 All specifications are typical @+25°C with nominal input voltage under full output load conditions, unless otherwise noted. Specifications subject to change without notice. >> 2 1111 Knox Street Torrance CA 90502 USA Tel: +1 310 202 8820 sales@martekpower.com www.martekpower.com MW400S Active Power Factor Correction & Isolated Output Module OUTPUT CHARACTERISTICS PFC HIGH VOLTAGE BUS CHARACTERISTICS Nominal / Voltage Internal Holdup Capacitance External Holdup Capacitance (customer supplied) Min. Output Holdup Voltage Output Holdup Time Min. 375 Typ. 385 200 0 190 24 20 Max. Units 390 Vdc μF 600 μF 200 Vdc mS CONTROLS INTERFACE CHARACTERISTICS Referenced to floating Signal Ground Min. TTL Logic Disable Current TTL Logic Disable Voltage Sync Input Voltage Sync Input Frequency Sync Input Duty (High) Sync Output Voltage Status “OK” Status “Bad” @ 2mA AC OK Threshold AC “Bad” Response Time Output OK Threshold Turn-on Overshoot Standby 13V Standby 13V Load 1 Typ. 135 0 4.5 500 15 4 4.4 0 88 90 8 ±7 ±5 12 0 Max. Units 150 μA 0.8 V 5.1 Vp-p 550 kHz 55 % 5 Vp-p 5 V 0.8 Vdc 95 Vac 10 mS ±9 %Vout 1501 mV V 15 mA 15 150mV or 3% Vout, whichever is greater. Min. Typ. Max. Units Set Point Accuracy 501 mV Load Regulation 25/0.52 mV/% Line Regulation 5/0.1 20/0.23 mV/% Ripple P-P (10 MHz) 60 100/14 mV/% Overvoltage Protection 2 - 5 Vout 125/0.75 %/Vout 12 - 28 Vout 125 %/Vout Transient Response Time - Overshoot 20 - 80% Load (@Nom.Line) 200/100 500/2506 μS/mV 115 - 180Vac per MIL-STD-704A 500/2506 μS/mV 102 - 124Vac per MIL-STD-704A 500/2506 μS/mV 92 - 138Vac per MIL-STD-1299 500/2506 μS/mV 163 - 281Vac, 50 Hz 500/2506 μS/mV 240 - 350Vdc per MIL-STD-704E 500/2506 μS/mV 50 - 100% Load (@Nom.Line) 200/100 500/2506 μS/mV Temperature Drift 0.02 0.05 %/oC Long Term Drift 0.02 0.05 %/1KHrs Current Limit 110 125 140 %/Iout Short Circuit Current 25 50 75 %/Iout Load Capacitance 2007 μF Remote Sense Compensation 0.5/108 Vdc/% Trim Range 90 110 %/Vout Turn On Time 260 300 mS Logic Turn On Time 8 10 mS 1 2 3 4 5 6 7 8 ISOLATION CHARACTERISTICS TEMPERATURE CHARACTERISTICS Operating1 Storage - Ambient Over Temperature Shutdown2 1 2 Min. -40 -55 Typ. +106 or 1% maximum, whichever is greater whichever is greater from No Load to Full Load with line constant whichever is greater from Low Line to High Line at Full Load whichever is greater measured at 10 MHz Bandwidth or 0.7V maximum, whichever is greater or 5% maximum, whichever is greater or 3X Co, whichever is greater lesser of 10% of Vout or 0.5V Max. Units o +100 C o +125 C o +115 C Start-up guaranteed to -55oC Measured at baseplate (center line of output connector x center line of baseplate) Isolation Input to Case Input to Output Input to Signal Ground Output to Case Signal Ground to Output to Case Insulation Resistance @ 50Vdc Min. Units 1000 1000 1000 250 250 50 Vdc Vdc Vdc Vdc Vdc Mohm All specifications are typical @+25°C with nominal input voltage under full output load conditions, unless otherwise noted. Specifications subject to change without notice. >> 3 1111 Knox Street Torrance CA 90502 USA Tel: +1 310 202 8820 sales@martekpower.com www.martekpower.com MECHANICAL CHARACTERISTICS M-GRADE - ENVIRONMENTAL SCREENING Stabilization Bake Temperature Cycling Burn in Final Testing MTBF @ 50oC, GB Weight +105oC for 24 hours similar to MIL-STD883, M1008.2, Condition B 10 cycles at -55oC to +105oC (transition period 5oC/ min) similar to MIL-STD-883, M1010, Condition B 150 Hours at 85oC min. Full ATP 144,830 Hours Size Volume Material Case Baseplate Finish Case Baseplate Mounting Standard Option - I I-GRADE - ENVIRONMENTAL SCREENING Burn in Final Testing MTBF @ 50oC, GB 43.3 1230 6.5 x 8.0 x 1.00 165 x 203 x 25.4 52.0 852 16 Hours @ 50oC min. Full ATP 71,330 Hours oz. grams inch mm inch3 cm3 Steel, 0.024” Aluminum Alloy Nickel Plated None 6-32 THD Inserts Metric M3 X 0.5 CASE DRAWING TOP VIEW MOUNTING HOLE 6-32 UNC X .30/7.6 DEEP 9 places BOTTOM VIEW 6.000/ 152.4 6.50/ 165.1 3.000 /76.2 .25/ 6.3 .25/6.3 MAX 2.40/ 60.9 7.500/190.50 3.40/86.3 Socket A1 .550/ 13.97 Output Connector J2 FUNCTION PIN No. - Output A1, A2, A3 + Output A5, A6, A7 Not Used A4 Out OK 5 13V STBY15mA 1 Signal Gnd 14, 15 + Sense 10 - Sense 9 TTL 3 Sync 17 Trim 7 AC OK 12 2, 4, 6, 8, 11, 13, 16 Not Used PIN 1 1.00/25.4 Socket 1 J1 INPUT CONNECTOR DAMME15PF - A101 .25/6.3 3.750/95.25 8.00/203.2 J2 OUTPUT CONNECTOR DDME24H7SJ .040/ 1.03 Input Connector J1 PIN No. FUNCTION 1, 9 AC1 3, 10 AC2 8, 15 Chas Gnd 6 Ext. Cap (+) 5 Ext. Cap (-) 2, 4, 7, 11, 12, 13,14 Not Used Tolerances: inches - x.xx x.xxx = ±0.03 = ±0.015 mm - x.x x.xx = ±0.8 = ±0.40 All specifications are typical @+25°C with nominal input voltage under full output load conditions, unless otherwise noted. Specifications subject to change without notice. >> 4 1111 Knox Street Torrance CA 90502 USA Tel: +1 310 202 8820 sales@martekpower.com www.martekpower.com MW400S Active Power Factor Correction & Isolated Output Module PERFORMANCE CHARACTERISTICS 1. Power Factor vs. Input Voltage 2. Power Factor vs. Output Power 1.0 85% 50 Hz 60Hz 115Vac Power Factor 60 Hz .96 .94 At 400 W Load .92 50Hz 230Vac 5V 80% 400Hz 115Vac 0.90 0.85 24V 12V 3.3V 75% Full Load 0.80 400 Hz 70% .90 2V 0.75 .88 0.70 90 115 136 180 230 265 65% 100 200 4. Efficiency vs. Output Power 85% 300 400 90 115 136 180 Output Power (watts) Input Voltage (rms) 230 265 Input Voltage (rms) 6. Output Ripple (5Vout) 5. AC Input Voltage & Current 28V 24V Input Current 12V 100 mV/div 5V 3.3V 5A/div 15V 80% 75% Vin = 115 Vac/60Hz 70% 50 V/div Efficiency 15V 28V 0.95 Efficiency .98 Power Factor 3. Efficiency vs. Input Voltage 1.00 2V Vin = 115 Vac/60Hz, Full Load Vin = 115 Vac/60Hz, Full Load Input Voltage 65% 100 150 200 250 300 350 400 Time: 5 mS/div Output Power (watts) 7. Load Transient Response (5Vout) Time: 5μS/div 8. Line Transient (60 Hz), no response at output 9. Line Transient (400 Hz), no response at output Low Line to High Line 115 V - 180 Vac, 400Hz, Full Load 200 V/div 50 V/div Input Voltage 50 V/div 100 mV/div 100 V/div Low Line to High Line 92 V - 138 Vac, 60Hz, Full Load Vin = 115 Vac/60Hz, 20% to 80% of Full Load 380V Bus Voltage 380V Bus Voltage Time: 100 mS/div Time: 100μS/div 10. Line Transient (50 Hz), no response at output 200 V/div 100 V/div Vin = 115 Vac/60Hz, Full Load Time: 100 mS/div 10 A/div Input Current 5V/div 10 A/div 200 V/div Input Voltage Input Current 380V Bus Voltage 50 V/div 12. Turn-on Input Voltage & Input Current vs. Output Voltage 11. Inrush Current vs. Intermediate Bus Low Line to High Line 163 V281 Vac, 50Hz, Full Load 380V Bus Voltage Time: 100 mS/div Output Voltage Time: 100 mS/div Vin = 115 Vac/60Hz, Full Load Time: 50 mS/div >> 5 1111 Knox Street Torrance CA 90502 USA Tel: +1 310 202 8820 sales@martekpower.com www.martekpower.com MW400S Active Power Factor Correction & Isolated Output Module PERFORMANCE CHARACTERISTICS 13. Turn-on Input Voltage & Input Current vs. Output Voltage 15. TTL Turn-Off 14. TTL Turn-On Output Voltage 5 V/div 5 V/div Output OK 5 V/div Vin = 230 Vac/50Hz, Full Load Output Voltage Output Voltage Vin = 115 Vac/60Hz, Full Load Time: 50 mS/div Output OK 5 V/div 10 A/div 5 V/div Input Current TTL 5 V/div TTL 5 V/div 400 V/div Input Voltage Vin = 115 Vac/60Hz, Full Load Time: 500 μS/div Time: 5 mS/div 16. Input Voltage Turn-Off vs. Output Voltage 18. Input Voltage Turn-On vs. AC OK 17. Input Voltage Turn-Off vs. AC OK Input Voltage 100 V/div Output Voltage 100 V/div 100 V/div Input Voltage 5 V/div Vin = 115 Vac/60Hz, Full Load Input Voltage AC OK Vin = 115 Vac/60Hz, Full Load AC OK 5 V/div 5 V/div Vin = 115 Vac/60Hz, Full Load Time: 10mS/div Time: 5 mS/div Time: 10 mS/div 19. Free-running Sync Output 20. Output Converter Voltage Loop Gain & Phase (5Vout) 21. Output Converter Voltage Loop Gain & Phase (28Vout) db db 50 150o PHASE 150o 50 1 V/div PHASE 0 0 Vin = 115 Vac/60Hz, No Load GAIN -150o -50 100Hz Time: 500 nS/div 1kHz 10kHz 100kHz 22. MIL-STD-461D CE101-4 dBμV 100 dBμA -150o -50 100Hz 1kHz 80 60 0.00001 Vin = 115 Vac/60Hz, Full Load 80 70 60 50 0.001 0.01 0.01 0.1 Torrance 1 MHz MHz 1111 Knox Street 100kHz 40 30 20 10 0 Vin = 115 Vac/60Hz, Full Load 0.00003 10kHz 23. MIL-STD-461D CE102-1 120 20 GAIN 110 100 90 140 40 0 0 CA 90502 USA Tel: +1 310 202 8820 10 >> 6 sales@martekpower.com www.martekpower.com MW400S Active Power Factor Correction & Isolated Output Module 18 V PFC BOOST CONTROLS +380 VDC ISOLATED HOUSEKEEPING SUPPLY INPUT 18 V UNDERVOLTAGE LOCKOUT & AC OK INDICATION 14 V 18 V SYNC 2 ENA POWER UP TIME DELAY OPTO SYNC 2 SYNC 1 BOOST OVERVOLTAGE DISABLE VCC 1 C113 - - OUT - SENSE TRIM OPTO 18 V XMFR BIDIRECTIONAL SYNC VCC3 CIRCUIT SIGNAL GND XMFR SYNC BOOST RTN SDN +380 VDC VCC 2 380V PFC HIGH VOLTAGE BUS DC OK CIRCUIT OPTO DC OK RTN 2 VCC 2 14 V LIMITER RTN 2 VCC 3 } S+ S- PHASE SHIFT CONTROLS SYNC 1 POST FILTER OUTPUT CONNECTOR GATE DRIVE FILTER +SENSE +OUT VCC 2A 13 V OUTPUT SHUTDOWN LOGIC FOR: DC OK, TTL, OUTPUT OVER VOLTAGE, OVER TEMPERATURE, & OUTPUT OK INDICATION OUTPUT OK OPTO 14 V TTL OPTO SYNC AC OK SIGNAL GND } 13V STANDBY OVERCURRENT PROTECTION CIRCUIT OUPUT CONNECTOR 14 V VDC RTN SOFT START RTN 2 BOOST RTN - CS 2 RS AC B ISOLATED FULL BRIDGE BOOST CONVERTER GATE DRIVE EMI FILTER AVERAGE CURRENT +380 VDC + VCC 2A AC 2 AC A } - CS 1 AC 1 + EXT. CAP. + INPUT CONNECTOR EXT. CAP. - C113 + BRIDGE RECTIFIER FOR OUTPUTS >= 12V ACTIVE PRELOAD VCC 2A COMMON MODE BEAD SDN } CHASSIS SCR GATE INPUT CONNECTOR BLOCK DIAGRAM OF MW400S SIGNAL GND All specifications are typical @+25°C with nominal input voltage under full output load conditions, unless otherwise noted. Specifications subject to change without notice. >> 7 1111 Knox Street Torrance CA 90502 USA Tel: +1 310 202 8820 sales@martekpower.com