FC-Series Camera Quick Connect Guide

advertisement
427-0073-12-28 FC-Series S Quick Connect.fm Page 1 Friday, May 16, 2014 9:06 AM
FC-Series Camera
Quick Connect Guide
3 mm hex
key
Items Included in Kit
2.4 mm slotted
screwdriver
For installations that are using the Concealed Cable Mounting Arm, refer to the
installation manual for instructions:
FLIR FC-Series Installation Manual (427-0073-12-12)
Caution!
Except as described in this guide, do not disassemble the FC-Series camera.
Damage to the camera can occur as the result of careless handling or
electrostatic discharge (ESD).
Prior to making any connections, ensure the power is switched off.
Note
Power: Power Over Ethernet Plus (PoE+) or 14 - 32 Vdc or 18 - 27 Vac
Power terminal blocks: wire size from 16 AWG to 20 AWG
Analog Video Cable: BNC-terminated RG-59/U solid-center coax cable
Accessory I/O Cable: wire size 26 AWG, stranded (1 mm diameter including
insulation) Phoenix Contact 1780493 spring-cage and pierce contact technology
427-0073-12-28 Rev 100
May 2014
427-0073-12-28 FC-Series S Quick Connect.fm Page 2 Friday, May 16, 2014 9:06 AM
Step 1 Remove cover: Using 3 mm hex key, loosen four captive
screws. Removal of sunshield not necessary.
Access captive screws
through slots in sunshield.
Step 2 Install cables through sealing gland:
Gland nut
Video coax
Re-tighten gland nut after
installation is completed.
Fill any unused hole with
orange plug.
Accessory
Ethernet
Ground
Power cable
Step 3 If using conventional power cable, strip cable as described
below:
Strip ends 3 Places
(0.2±.04 in)
6.0±1 mm
427-0073-12-28 Rev 100
Min diameter = 6.8 mm (0.27 in)
Max diameter = 9.4 mm (0.37 in)
Remove outer jacket
(0.8±.20 in)
20.0±5 mm
Power Cable
May 2014
427-0073-12-28 FC-Series S Quick Connect.fm Page 3 Friday, May 16, 2014 9:06 AM
Step 4 Terminate cables:
Connection
Purpose
1
3-pin Jumper
Lens heater on/off
2
RCA
Analog video test point
3
BNC
Analog video
4
3-pin Terminal
AC/DC Power
5
Ethernet
PoE power, communications, IP video stream
6
6-pin terminal J8
General purpose I/O (GPIO)
7
Reserved for future use
Do not connect
Table 1-1: Power Connector
1
Chassis
2
Vac/dc -
3
Vac/dc +
Table 1-2: GPIO Connections - J8
Pin
Connection
Pin
Reserved J3
GPIO J8
Connection
1
Chassis ground
4
GPIO In
(digital ground)
2
GPIO Out
5
GPIO In (+5V)
3
GPIO Out
6
Chassis ground
pin 1
Caution!
Pins 4 and 5 should not be connected to any voltages or power sources outside
the camera. Damage to the camera may result.
427-0073-12-28 Rev 100
May 2014
427-0073-12-28 FC-Series S Quick Connect.fm Page 4 Friday, May 16, 2014 9:06 AM
Step 5 Connect a ground wire between the ground stud on the back
of the camera and the nearest earth-grounding point.
Step 6 Test camera: Power on the camera and test video.
Use a web browser to test IP communications
(default IP: 192.168.250.116; login: user/fliradmin)
Step 7 Tighten Cable seal gland nut to ensure a watertight seal.
Step 8 Replace cover: Alternately tighten the four captive screws in
the cover; torque to 1.8 N-m (16.0 in-lbs).
FLIR Systems, Inc.
70 Castilian Drive
Goleta, CA 93117
USA
PH: + 1 805.964.9797
PH: + 1 877.773.3547 (Sales)
PH: + 1 888.747.3547 (Support)
FX: + 1 805.685.2711
www.flir.com
Corporate Headquarters
FLIR Systems, Inc.
27700 SW Parkway Ave.
Wilsonville, OR 97070
USA
PH: +1 503.498.3547
FX: +1 503.498.3153
sales@flir.com
Ensure the camera is properly grounded. Failure to properly ground the camera
can lead to permanent damage to the camera. Typical to good grounding
practices, the camera chassis ground should be connected to the lowest
resistance path possible. FLIR requires a grounding strap anchored to the
grounding lug and connected to the nearest earth-grounding point.
Before installing the FC-Series camera you should read and understand the
following documents which provide details regarding mechanical dimensions
and installation safety.
•
FLIR FC-Series Installation Manual (427-0073-12-12)
•
FLIR FC-Series S Interface Control Document (427-00XX-XX-19S)
Documents provided on the documentation CD or from the FLIR website
427-0073-12-28 Rev 100
May 2014
Related documents