(QSNE-4A-D) IMPORTANT NOTES ww co m 1. Manual Programming: This document describes manual programming via the buttons on the front of the Energi Savr NodeT unit. For programming using the Apple iPod touch or iPhone mobile digital devices, please see the Energi Savr app available from the Apple AppStore online marketplace. 2. Only use compatible LutronR sensors and controls. Energi Savr NodeT (ESN) Unit w. l u t r o n . Lutron GL LTD +65.6220.4666 +65.6220.4333 www.lutron.com/asia This guide is divided into sections to . Each section deals with a particular feature or set of features of the ESN and the equipment connected to it. Depending on the connected equipment and the intended use of your ESN, some sections may not apply. See below to determine which sections should be read. S4 CCI Zone 1 Zone 2 Zone 3 Zone 4 Type Hi Temp Prog Power QSNE-4A-D DIN Rail Power Module Photo Occ Switch Option Def H Opt1 M Opt2 L Input Hi Temp Prog Power Option Def M Opt2 L QS Sensor » Module » S4 CCI Energi Savr NodeT (ESN) Unit Zone 1 Zone 2 Zone 3 Zone 4 ESN Wired Input Setup Hi Temp Prog Power QSNE-4A-D Photo Occ Switch DIN Rail Power Module IR Input 230 V~ 50 / 60 Hz 10 A Option Def H Opt1 M Opt2 L Opt3 www www.lutr on.com +44.(0)20.7702.0657 www.lutron.com Emergency Dry Contact Closure Input 800 W Max 800 500WWMax Max 500 500WWMax Max 500 500WWMax Max 500 W Max Input S1 Input S2 S1 S3 IR Photo IR OccPhoto Switch Occ Switch S2 S4 S3 CCI S4 CCI Zone 1 Zone Zone12 Zone Zone23 Zone Zone34 Zone 4 Prog Prog Infrared (IR) Sensor -or- H Opt1 M M Opt2 Opt2 L L Opt3 Opt3 » » Subsection: Assign Zones to QSM Inputs » Wired Daylight Sensor Dry Contact Closure Switch Wires to multi-function Input » ESN Wired Input Setup ESN Wired Input Setup Wires to multi-function Input » ESN Wired Input Setup LUTRON Wires to multi-function Input » Daylighting Setup » Subsection: Assign Zones to QSM Inputs Unit was overheated and has now cooled to acceptable temperature “Prog” (Program) Off Device in Normal Mode Flashing: 1 blink/sec Device in Program Mode “Zone 1-4” Off Normal Operation: zone off Continuous On Normal Operation: zone on 1 blink, pause Output shorted: verify wiring and do one of the following to turn on affected zone: - Press affected “Zone” button then press to raise on the unit - Press a scene button on a connected QS device - Press Reset button next to CCI terminal - Power cycle unit 2 blink, pause Overvoltage: contact Lutron 3 blink, pause Shorted component: contact Lutron 4 blink, pause Overtemperature: zone may be overloaded, all loads scaled to 25% 5 blink pause Overtemperature: zone may be overloaded, all loads turned off 800 W Max 500 W Max 500 W Max 500 W Max S1 S2 S3 S4 CCI Zone 1 Zone 2 Zone 3 Zone 4 Type IR Photo Occ Switch Hi Temp Prog Power 230 V~ 50 / 60 Hz 10 A Option Def H Opt1 M Opt2 L Normal operation Rapid flash: 10 blinks/sec Emergency mode/Contact open/Jumper missing “Input” Continuous On Viewing wired input Flashing: 1 blink/sec Viewing remote input on a QS Sensor Module (QSM) Off Sensor never detected or not currently receiving information Sensor is detected and is currently receiving information “Def, Opt 1-3” (Default, Option 1-3) Off Flashing/On Device in normal mode Selected option for programming mode Troubleshooting using symptoms: Symptom Cause Solution Unable to add daylight sensor to a zone Not allowed to assign 16th occupancy sensor to a zone Daylight sensor fails to turn on a zone Existing daylight sensor already assigned to the zone Existing occupancy sensor still assigned to the zone Unassign the existing daylight sensor and try again Unassign the existing occupancy sensor and try again Daylight sensors will not turn a zone on if an occupancy sensor assigned to that zone detects that the room is vacant Switched zone daylighting: Reset the daylighting set point. Daylighting Setup incorrect light level set during See Daylighting Setup When associating a A QSM has already been To clear the QSM association and any QSM to the ESN, the associated to the ESN ESN zone assignments to any QSM inputs, “Input” LED on the ESN press and hold the “Input” button on the flutters for 1 second, ESN for 10 seconds. The “Input” LED will then turns off flutter for 1 second, then turn off When associating a Maximum number of Unassign any unnecessary wireless inputs wireless input device associations to the QSM has of that device type and try again to a QSM, the QSM been exceeded for that responds with 10 short wireless input device type beeps When associating a Input device is already If you choose to ignore the warning and try wireless input device associated to another QSM to associate the same input device to the to a QSM, the QSM on the QS link QSM a second time, the input device will be responds with 5 short removed from association with the previous beeps QSM and will now be associated with the new QSM. Note: This will also remove any ESN programming that the wireless device may have had through the previous QSM Subsection: Assign Zones to PicoR Wireless Controller (through QSM) Occupancy sensor is overriding the zone Wired seeTouchR QS Wallstation Input Input Multiple errors: contact Lutron Continuous On Continuous On/Flashing If you have other devices wired to the ESN QS Link terminal block, see below to determine which additional sections to read. QS Link Energi Savr NodeT Unit (ESN) Rapid flash:10 blinks/sec “CCI” (Contact Closure Input) “Input S1-S4” OTHER QS LINK DEVICES Additional Sections: Opt3 www.lutron.com +44.(0)20.7702.0657 » LUTRON Wired seeTouchR QS Wallstations Setup GRAFIK EyeR QS Control Unit BUTTON AND LED LOCATIONS Additional Sections: » CCO 1 CCO 2 CCO 3 CCO 4 CCO 5 8 7 6 5 4 3 2 1 QSE-IO 24 V 100 mA 800.523.9466 +1.610.282.3800 243C IND. CONT. EQ. www.lutron.com/qs 0 2 7 5 5 7 6 1 32 3 V 0-24 V 0-24 V GRAFIK EyeR QS Control Unit Setup QSE-IO Input/Output Interface 800 W Max 500 W Max 500 W Max 500 W Max Input S1 S2 S3 S4 CCI Zone 1 Zone 2 Zone 3 Zone 4 Type IR Photo Occ Switch Input Hi Temp Prog Power 230 V~ 50 / 60 Hz 10 A Option Def H Opt1 M Opt2 L Opt3 www.lutron.com +44.(0)20.7702.0657 Inputs 1 Additional Sections: R R 1A ½A V 5 COM CCO 5 NO CCO 5 NC Zones COM CCI 5 CCI 4 CCI 3 CCI 2 CCI 1 4 3 2 1 CCO 4 NO CCO 4 NC 3-4 COM CCO 3 NO CCO 3 NC QS MUX Daylighting Setup Occupancy Setup Subsection: Assign Zones to QSM Inputs » Subsection: Assign Zones to QSM Inputs MUX » » » » COM V+ ESN Wired Input Setup Daylighting Setup Additional Sections: CCO 2 NO CCO 2 NC 1-2 COM CCO 1 NO CCO 1 NC » ESN Wired Input Setup » Additional Sections: ® » Subsection: Assign Zones to QSM Inputs Pico® Wireless Controller STAT Additional Sections: Occupancy Setup Infrared (IR) Sensor Wires to multi-function Input Additional Sections: Flashing: 1 blink/sec Additional Sections: Wired Occupancy Sensor Wired Daylight Sensor Unit is too hot, loads turned off QS Sensor Module (QSM) Input Setup QS Sensor Module (QSM) Zone Assignment Wireless Daylight Sensor 500-13491 Rev. B N OR TUL +44.(0)20.7702.0657 +44.(0)20.7702.0657 www.lutron.com 230 V~ 50 230 / 60 V~ Hz50 10/ 60 A Hz 10 A www.lutron.com Unit is too hot, loads scaled to 25% power Continuous On Additional Sections: Occupancy Setup N O R Power Power H Opt1 QSNE-4A-D Input Hi TempHi Temp Option Option Def Def DIN Rail Power Module Input QSNE-4A-D Type DIN Rail Power Module Type Normal Operation 1 second on, 7 seconds off Wireless Occupancy Sensor » QSNE-4A-D S3 Off Subsection: Associating Wireless Input Devices to a QSM » DIN Rail Power Module S2 N OR TUL » QSE-IO Input/Output Interface Setup 800 W Max 500 W Max 500 W Max 500 W Max Input S1 S2 S3 S4 CCI Zone 1 Zone 2 Zone 3 Zone 4 Type www.lutron.com Lutron, GRAFIK Eye, Pico, seeTouch and ) are registered trademarks, and Energi Savr Node and Radio Powr Savr are trademarks of Lutron Electronics Co., Inc. Apple, iPhone, and iPod touch are trademarks of Apple Inc., registered in the U.S. and other countries. AppStore is a service mark of Apple Inc. © 2013 Lutron Electronics Co., Inc. P/N 032416 Rev. A 08/2013 ® Button LED Photo Occ Switch Input Hi Temp Prog Power QSNE-4A-D IR DIN Rail Power Module » S1 Type R Read: 800 W Max 500 W Max 500 W Max 500 W Max Input Read: » CONFIGURATION WHEN USING WIRED INPUTS All Wired Inputs General system failure/No power; verifiy breaker is on Opt3 Additional Sections: After Load Setup, if you have wired sensor inputs wired directly to the Energi Savr NodeT (ESN) unit multi-function input terminal blocks, see below to determine which additional sections to read. Off Wires to “QS Link” Terminal Block on ESN H Opt1 www.lutron.com +44.(0)20.7702.0657 230 V~ 50 / 60 Hz 10 A Opt3 www.lutron.com +44.(0)20.7702.0657 230 V~ 50 / 60 Hz 10 A Zone 1 Zone 2 Zone 3 Zone 4 Subsection: Associating Wired Input Devices to a QSM LUTRON S3 CCI Additional Sections: 800 W Max 500 W Max 500 W Max 500 W Max S2 S4 Wired Occupancy Sensor Input IR S3 Read: Energi Savr NodeT with Phase Adaptive Control (QSNE-4A-D) S1 S2 Photo Occ Switch Read: Load Setup Input IR Communicates with QSM via Radio Frequency (RF) Read: » 800 W Max 500 W Max 500 W Max 500 W Max S1 Type Wires to Input Terminal Blocks on QSM All Energi Savr NodeT (ESN) units Normal operation Input QSM Wireless Input Devices LOAD SETUP Description Continuous On QS Sensor Module (QSM) QSM Wired Input Devices » LED Behavior “Power” “Hi Temp” (High Temperature) QS Link USING THIS GUIDE LED QSNE-4A-D +44.(0)20.7702.0657 +44.(0)20.7480.6899 www.lutron.com/europe QSNE-4A-D Lutron EA LTD Energi Savr NodeT with Phase Adaptive Control LED Diagnostic Indicators After Load Setup, if you have a QSM wired to the ESN QS Link terminal block, read sections QS Sensor QS Sensor Module (QSM) Zone Assignment. Some parts of the section Module (QSM) Input Setup and may not apply, depending on the devices connected to the QSM. See below to determine which additional subsections to read for each type of connected device. DIN Rail Power Module English manual programming guide TROUBLESHOOTING CONFIGURATION WHEN USING QS SENSOR MODULE (QSM) DIN Rail Power Module Energi Savr NodeTM 230 V~ 50 / 60 Hz 10 A Lutron Electronics Co., Inc. | 7200 Suter Road Coopersburg, PA 18036-1299, U.S.A. Technical Assistance | 1.800.523.9466 USA, Canada, and the Caribbean | +44.(0)20.7702. 0657 Europe | +65.6220.4666 Asia | +.610.282.3800 Others | www.lutron.com Option Def H Opt1 M Opt2 L Opt3 www.lutron.com +44.(0)20.7702.0657 Page 1 of 4 Figure C QS Sensor Module (QSM) Input Setup LEDs and BUTTON PRESSES LED states: Off On a. Occupancy Sensor (“Occ”): Assign zone(s). Press and hold the “Zone” button of any zone for 3 seconds to assign the zone Associating Wireless Input Devices to a QSM See visual instructions on left. See written instructions at right. Blink/Flash Energi Savr NodeTM (ESN) Wired Input Setup - continued 1. Enter QSM Wireless Input Setup 2. QSM 3. Associate Devices “Occ” “Photo” (Occupancy Sensor) QSM Pico® (Daylight Sensor) to the selected input. A flashing “Zone” LED indicates an assigned zone. Exit Setup the selected input. A flashing “Zone” LED indicates an assigned zone. Note: Each zone can only be assigned to a single daylight sensor input. The zone must be unassigned from the input before assigning to a different daylight sensor input. 800 W Max 500 W Max 500 W Max 500 W Max Inputs Input S1 S2 S3 S4 CCI Zone 1 Zone 2 Zone 3 Zone 4 Type Prog Power QSNE-4A-D Photo Occ Switch DIN Rail Power Module IR Hi Temp Option Def H Opt1 M Opt2 L To unassign a zone, press and hold the “Zone” button of the desired zone for 3 seconds. The “Zone” LED will turn off to indicate an unassigned zone. Zones Repeat steps 7 and 8 for each desired input. Opt3 www.lutron.com +44.(0)20.7702.0657 230 V~ 50 / 60 Hz 10 A 800 W Max 500 W Max 500 W Max 500 W Max S1 S2 S3 S4 CCI Press and hold 6 seconds Press and hold 3 seconds Input Zone 1 Zone 2 Zone 3 Zone 4 Press and hold 6 seconds Press and hold 6 seconds Press and hold 3 seconds Type LED Prog Power H Opt1 M Opt2 L 1. Enter QSM / ESN Association 2. Opt3 Input Hi Temp Prog Figure A Load Setup 2. Enter Zone Setup Power 3. Select Zone (if applicable) Zone 1 Zone 2 Zone 3 Zone 4 Input Hi Temp Press 4. Change Setting Option Def 800 W Max 500 W Max 500 W Max 500 W Max Prog Select Option M Opt2 L Press and hold 3 seconds S2 S3 S4 CCI Power Input Opt1 Hi Temp Opt2 Prog Opt3 Power Press and hold 3 seconds 6. Input Opt1 Hi Temp Opt2 Prog Opt3 Power S2 S3 S4 CCI 7. S2 S3 S4 CCI Power S1 Zone 1 Zone 2 Input Opt1 Hi Temp Opt2 Prog Opt3 Power Press and hold 3 seconds IR QSNE-4A-D Prog CCI Zone 1 Zone 2 option. When setting the Daylight Gain, high/low end trim, or the minimum light level option, the “H-M-L” LEDs will flutter when the limit has been reached. Option Def Photo Occ Switch Input Opt1 Hi Temp Opt2 Prog Opt3 Power Option Def LED Option Def Occupancy / Vacancy Opt1 Opt2 Opt3 S2 S3 S4 CCI Function Occupancy (default) M Vacancy for more light for less light Opt 1 Daylight Gain H-M-L Press Press Opt 2 1 Load Type2 H-M-L H M L Unassigned/Non-dim (default)3 Auto (dim) (phase detection) MLV (dim) (leading edge / forward phase) ELV (dim) (trailing edge / reverse phase) H-M 100% maximum (default) down to 55% minimum Zone 1 Zone 2 Option Def Input Opt1 Hi Temp Opt2 Prog Opt3 Power Press and hold 3 seconds Opt 3 Photo Occ Switch Option Def High-End Trim Opt1 Scene Mode Allows IR remote to select scenes Scene Setup for more infomation) (see Opt 2 Zone mode (default) Allows setting of preset light levels for each zone To unassign a zone, press and hold the “Zone” button of the desired zone for 3 seconds. The “Zone” LED will turn off to indicate an unassigned zone. Repeat steps 7 and 8 for each desired input. Opt3 Press Def + Opt 1 Low-End Trim L-M 1% minimum (default) up to 45% maximum Def + Opt 2 Absolute Minimum Light Level 4 H-M-L 100% maximum down to 0% minimum (default) 800 W Max 500 W Max 500 W Max 500 W Max Def + Opt 3 RTISS-TE H Enable L Disable (default) Switch Action Maintained Feature Zone Toggle Preset / Off (default) Opt 1 Momentary Zone Toggle Preset / Off Opt 2 Maintained (dual action) Zones Preset / Off Opt 3 Momentary (single action) Zones On Function Contact closure or opening will toggle the state of assigned zones between a preset and off.* Contact closure will toggle the state of assigned zones between a preset and off.* Contact closure will set assigned zones to preset level. Contact open will set assigned zones off. Contact closure will set assigned zones to preset level. Contact open will set assigned zones off. * If one or more assigned zones are on at the time of contact closure or opening, all assigned zones will turn off. Set zone level. Select zone by pressing the “Zone” button for the zone you wish to set up, then use the the zone’s preset light level. 1 2 Note: Selecting the wrong dimming type may result in poor dimming performance and may damage the load and/or the Energi Savr NodeT unit. Consult fixture manufacturer if unsure of proper dimming type. To determine the load type during normal operation, press the “Option” button. The “Zone” LEDs will blink: Solid On = trailing edge/reverse phase 1 blink / sec = leading edge/ forward phase 3 Zone 1 Zone 2 Zone 3 Zone 4 4 Each zone is unassigned by default and will switch load on or off until it is configured. Once configured, the load type cannot be changed back to Unassigned/Non-Dim. This setting is required in certain cities. Check local electrical codes to verify requirements. Repeat steps 2 and 3 for each desired zone. Press and hold 3 seconds LED Def Save the selected option. Press and hold the “Option” button for 3 seconds. The LED for the selected option will remain steady ON. Opt2 Setup Options Assign Zones a. b. Setting Choices H Press 800 W Max 500 W Max Photo Occ Switch DIN Rail Power Module Hi Temp QSNE-4A-D DIN Rail Power Module Input S4 Type IR Option Def S3 Input S1 Photo Occ Switch S2 Select Input Type IR IR 800 W Max 500 W Max Zone 1 Zone 2 S1 Zone 1 Zone 2 Press Input Type 8. Option Def Exit Change Sensor Type Mode 800 W Max 500 W Max Input S1 CCI Photo Occ Switch Press and hold 3 seconds Assign Sensor Type S4 2. Select Zone. Press a “Zone” button to select a zone. When a zone is selected, the zone's LED will blink once per second. 3. Select Option. Press the “Option” button to select an option. Use the and buttons for each zone to select the choice for each Type IR QSNE-4A-D Prog Option Def Photo Occ Switch DIN Rail Power Module Hi Temp QSNE-4A-D Input S3 Type IR Photo Occ Switch DIN Rail Power Module IR 800 W Max 500 W Max Input S2 Opt 1 Switch—IEC PELV/NECR Class 2 dry contact switch “Def” (Default), “IR” (Infrared), and “Photo” (Daylight) LEDs will blink once per second. 800 W Max 500 W Max S1 Zone 1 Zone 2 Type Type Press and hold 3 seconds Load Setup Select Sensor Type Input S1 Zone 1 Zone 2 QSNE-4A-D CCI DIN Rail Power Module S4 QSNE-4A-D S3 DIN Rail Power Module S2 4. Select Input Input S1 5. 3. 800 W Max 500 W Max 800 W Max 500 W Max Input Press and hold 3 seconds 1. Enter Zone Setup Mode. Simultaneously press and hold the “Prog” (Program) and “Input” buttons for 3 seconds. The “Prog,” QSNE-4A-D Enter Change Sensor Type Mode Opt3 PROGRAMMING Press and hold 3 seconds DIN Rail Power Module 2. Function d. Dry Contact (Switch): The LED for the currently saved option will be steady ON. Press the “Option” button to select the desired option. The LED for the selected option will flash. Figure B Energi Savr NodeTM (ESN) Wired Input Setup and Zone Assignment Enter Program Mode Option Save the selected option. Press and hold the “Option” button for 3 seconds. The LED for the saved option will remain steady ON. Set zone level (Zone Mode only). Select zone by pressing the “Zone” button for the zone you wish to set up, then use and buttons to adjust the zone’s preset light level. the Opt2 Power Press 1. Opt1 Hi Temp Press LED Option Def Prog Press and hold 3 seconds button to select the desired option. The LED for the selected option will flash. Assign zone(s). Press and hold the “Zone” button of the zone for 3 seconds to assign the zone to the selected input. A flashing “Zone” LED indicates an assigned zone. Input Opt3 Power Exit QSM / ESN Association Exit Zone Setup H Opt1 3. Associate QSM www.lutron.com +44.(0)20.7702.0657 230 V~ 50 / 60 Hz 10 A c. Infrared (“IR”) Sensor or Wired Wallstation: The LED for the currently saved option will be steady ON. Press the “Option” QSM Association to an ESN QSNE-4A-D Hi Temp Option Def DIN Rail Power Module Input QSNE-4A-D Button Photo Occ Switch DIN Rail Power Module IR 1. Repeat steps 7 and 8 for each desired input. b. Daylight Sensor (“Photo”): Assign zone(s). Press and hold the “Zone” button of any zone for 3 seconds to assign the zone to Button and LED Locations Input To unassign a zone, press and hold the “Zone” button of the desired zone for 3 seconds. The “Zone” LED will turn off to indicate an unassigned zone. 4. Exit Zone Setup Mode. Simultaneously press and hold the “Prog” and “Input” buttons for 3 seconds to exit. and buttons to adjust Assign zone(s). Press and hold the “Zone” button of the zone for 3 seconds to save the zone level and assign the zone to the selected input. A flashing “Zone” LED indicates an assigned zone. To unassign a zone, press and hold the “Zone” button of the desired zone for 3 seconds. The “Zone” LED will turn off to indicate an unassigned zone. Repeat steps 7 and 8 for each desired input. e. Emergency Input (“CCI”): The default emergency levels are 100% for all zones. Zones cannot be unassigned from emergency CCI input. Set zone level. Select zone by pressing the “Zone” button for the zone you wish to set up, then use the the zone’s emergency light level. and buttons to adjust Repeat steps 7 and 8 for each desired input. 9. Exit Program Mode. Press and hold the “Prog” (Program) button for 3 seconds to exit. QS Sensor Module (QSM) Input Setup Associating Wired Input Devices to a QSM Once wired inputs are connected to the QSM, upon power up, the QSM will automatically detect and configure the wired inputs after a valid signal is received. For example: occupied room, “IR” signal, etc. If any wired inputs are moved to a different connection on the QSM, the inputs will need to be re-detected. To force the QSM to re-detect all wired inputs, press and hold the “Prog” (Program) button for 10 seconds. Associating Wireless Input Devices to a QSM Wireless input devices must be associated to only one QSM before they are assigned to control system devices. 1. Enter Input Setup. Press and hold the “Prog” button on the QSM for 3 seconds. You will hear a 1-second beep upon entering, and c. d. Select Option the Status LED will blink. Save Selected Option Option Def Option Def Opt1 Opt1 Opt2 Opt2 Opt3 Opt3 Press Input Device Button Press For Device Feedback Maximum Per QSM Radio Powr SavrT Occupancy Sensor g/ Lights Off 6 seconds LED flashes briefly 10 will blink once per second. The Sensor “Input” LED will blink once per second to display the selected input, and the Sensor “Type” LED will be steady ON to display the inputs current type. Radio Powr SavrT Daylight Sensor Link 6 seconds LED flashes briefly 10 LEDs of sensors wired to the ESN will flash to help with identification. PicoR Wireless Controller Off Button 6 seconds None 10 1. Enter Program Mode. Press and hold the “Prog” (Program) button for 3 seconds. The “Prog” LED will blink once per second. The “Type” LED(s) will be steady ON showing the input type. One of the Sensor “Input” LEDs will be blinking to show the selected input. If all “Type” LEDs are steady ON, the selected input has not been assigned a sensor type. 2. Enter Change Sensor Type mode. Press and hold the “Input” and “Option” button for 3 seconds. The “Prog” and “Input” LEDs 800 W Max 500 W Max Input 9. Assign Zones* S2 H Zone 1 Zone 2 Zone 3 Zone 4 M Zone 1 Zone 2 Zone 3 Zone 4 IR Hi Temp Power Press and hold 3 seconds Press CCI Zone 1 Zone 2 3. Select Input. Press the “Prog” button to select an input. When an input is selected, the input’s LED will blink once per second. Also, 4. Select Sensor Type. Press the “Input” button to select a sensor type. When a sensor type is selected, the sensor’s “Type” LED will blink once per second. Photo Occ Switch Input Prog L Press S4 Type Program Mode Exit 800 W Max 500 W Max 500 W Max 500 W Max 800 W Max 500 W Max 500 W Max 500 W Max S3 QSNE-4A-D Set Zone Level S1 DIN Rail Power Module c. d. e. to the following table: Energi Savr NodeTM (ESN) Wired Input Setup Press and hold 3 seconds Set Zone Level Select Zone 2. Associate devices. For each wireless device you wish to associate, press and hold the appropriate button on the device according Option Def Opt1 Opt2 Opt3 Press and hold 3 seconds 5. Assign Sensor Type. Press and hold the “Input” button for 3 seconds fo assign the sensor type. After each successful input association, QSM will respond with 3 long beeps (2 seconds each). Note: If QSM responds in any other way, consult the Troubleshooting section on the first page of this guide. 3. Exit Input Setup. Press and hold the “Prog” button on the QSM for 3 seconds to exit. Repeat steps 3 - 5 to assign a sensor type for each desired sensor input. 6. Exit change Sensor Type mode. Press and hold the “Input” and “Option” button for 3 seconds to exit and return to Program Mode. QSM Association to an ESN 7. Select input. Press the “Prog” button to select an input. Corresponding LED will blink. Also, LEDs of sensors wired to the ESN will 1. Press and hold the “Prog” button on the QSM for 3 seconds. You will hear a 1-second beep upon entering, and the Status LED will 8. Setup options. Follow the appropriate section for each sensor type. 2. Associate QSM. On the ESN to which the QSM will be associated, press and hold the “Input” button for 3 seconds until the “Input” flash to help with identification. *Not applicable for step e blink. The “Input” (Input) LEDs on ESN(s) on the QS link will sequence through each sensor type, and the “Opt 3” (Option 3) LED will be steady ON. LED on the ESN unit begins to flash. 3. Exit QSM Association. Press and hold the “Prog” button on the QSM for 3 seconds to exit. Continued next column... ® Lutron Electronics Co., Inc. | 7200 Suter Road Coopersburg, PA 18036-1299, U.S.A. Technical Assistance | 1.800.523.9466 USA, Canada, and the Caribbean | +44.(0)20.7702. 0657 Europe | +65.6220.4666 Asia | +.610.282.3800 Others | www.lutron.com Page 2 of 4 Figure D QS Sensor Module (QSM) Zone Assignment Figure G QSE-IO Input / Output Interface Setup Scene Selection Control or Sequencing Control Assigning Zones to QSM Inputs (Occupancy, Daylight, IR) 2. Enter Program Mode 3. Select QSM Select Wired Input. Selected Input Blinks 800 W Max 500 W Max 800 W Max 500 W Max S2 S3 S4 CCI S2 S3 S4 CCI S1 Zone 1 Zone 2 Type Prog Power Photo Occ Switch Input Opt1 Hi Temp Opt2 Prog Opt3 Power IR QSNE-4A-D Hi Temp QSNE-4A-D Input Option Def S2 S3 S4 CCI Option Def Opt1 Hi Temp Opt2 Prog Opt3 Power Option Def Opt1 Opt3 Press and hold 3 seconds Zone Toggle Control Enter Zone Toggle Setup 2. 3. Select Input Selected Input Blinks S1 Set Zone Level Assign Zones S2 S3 S4 CCI Zone 1 Zone 2 Press and hold 6 seconds Hi Temp Press and hold 6 seconds Prog Power 800 W Max 500 W Max Input S2 S3 S4 CCI QSNE-4A-D Input Opt1 4. Hi Temp Prog Power 5. Assign Zones 800 W Max 500 W Max 500 W Max 500 W Max Opt3 Zone 1 Zone 2 Zone 3 Zone 4 Press Exit Zone Toggle Setup Press and hold 3 seconds Option Def Opt1 Opt2 1. Opt3 Partition Control Enter Partition/Sequencing Control Setup 2. 3. Select Input Assign Zones 4. Exit Partition/Sequencing Control Setup Zone 1 Zone 2 Zone 3 Zone 4 800 W Max 500 W Max Controllers (through QSM) Assigning Zones to Pico® Wireless Input Input Prog Power QSNE-4A-D DIN Rail Power Module Hi Temp Option Def Input S4 S1CCI S2 S3 Type Photo Occ Switch IR Option Def (IR receiver: Zone Mode Only) Input Input Opt1 Hi Temp Hi Temp Opt1 Opt2 Prog Prog Opt2 Opt3 Power Power Opt3 Option Def Press H Opt1 M Opt2 L Press and hold 3 seconds “Type” LED(s) will be steady ON showing the input type. Press 2. Select QSM. Press the “Input” button on the ESN to select QSM. The “Input” will blink once per second and the “Def” (Default) LED will be steady ON. 3. Select wired input: Each input from an associated QSM will be indicated by a steady ON “Type” LED as listed below: 4. Assign Zone Exit PicoR Wireless Controller Assignment 800 W Max 500 W Max 500 W Max 500 W Max Zone 1 Zone 2 Zone 3 Zone 4 LED Input Type Occ Photo IR Indicates an associated occupancy sensor (wired and wireless) from a QSM. Indicates an associated daylight sensor (wired and wireless) from a QSM. Indicates an associated IR receiver (wired only) from a QSM. Wireless Daylight sensor: Press and hold the “Link” button for 6 seconds, until the sensor’s dome begins to flash. The ESN will automatically select that input. S3 IR 2. S4 Photo Occ Switch IR DIN Rail Power Module 1 button wallstation: Dual column wallstations: Press and hold Press and hold top and bottom Input single button button of each column Hi Temp Prog Power S2 Zone 1 Zone 2 Select Option Type Option Def S3 S4 CCI Zone 1 Zone 2 Save Option Photo Occ Switch Input Opt1 Hi Temp Opt2 Prog Opt3 Power QSNE-4A-D S2 Type 4. Assign zones. Press and hold the “Zone” button of any zone for 3 seconds to assign the zone to the selected input. A flashing 800 W Max 500 W Max DIN Rail Power Module S1 Enter Wallstation Setup QSNE-4A-D 1. Input 800 W Max 500 W Max Input CCI S1 Select Button (Zone Toggle Only) Option Def “Zone” LED indicates an assigned zone. 5. Exit Program Mode. Press and hold the “Prog” button for 3 seconds to exit. 1. Enter PicoR wireless controller Assignment. Simultaneously press and hold the top and bottom buttons on the PicoR wireless Opt2 controller for 3 seconds. The QSM will beep for 1 second and the “Status” LED on the QSM will flash 3 times per second. The “Input” LED on the ESN(s) will flash once per second and the sensor “Type” LEDs will scroll through each input type. All unassigned zones will turn off. Opt3 2. Setup options. Press the “Option” button to select the desired option. The LED for the selected option will flash. Press and hold 3 seconds Press Note: Gray buttons signify buttons to be pressed. Press and hold 3 seconds Press LED Def 800 W Max 500 W Max 500 W Max 500 W Max Option Scene + Off mode LED Option Opt 2 Zone Mode (Only available with QSM 5.X or below) Opt 3 Single action zone mode (default) Input S1 S2 S3 S4 CCI Zone 1 Zone 2 Zone 3 Zone 4 DIN Rail Power Module IR Photo Occ Switch 800 W Max 500 W Max 500 W Max 500 W Max Input (Zone Mode Only) Option Def Power QSNE-4A-D Prog Opt1 M Opt2 L 4. Assign Zone Exit Wallstation Setup 800 W Max 500 W Max 500 W Max 500 W Max H Zone 1 Zone 2 Zone 3 Zone 4 Hi Temp 3. Set Zone Level Type Select Zone Press Scene mode and Zone Mode: Set zone levels. Use the the default light level of 100% will be saved. Press Press and hold 3 seconds Press and hold 3 seconds 1. 2. Enter GRAFIK EyeR QS Setup Assign Zones 3. Exit GRAFIK EyeR QS Setup 800 W Max 500 W Max 500 W Max 500 W Max Zone 1 Zone 2 Zone 3 Zone 4 LUTRON Press and hold 3 seconds Press and hold 3 seconds Press and hold 3 seconds A QSE-IO configured as a Sequencing Control can be used to start and stop automatic sequencing of scenes 5-16. 1. Enter Sequencing Control Setup. Press and hold the “Prog” button on the QSE-IO for 3 seconds. The 5 output LEDs on the QSE-IO will cycle. The sensor “Type” LEDs on the ESN(s) will scroll sequentially through each input type. 2. Assign zones. Press and hold the desired “Zone” button on the ESN unit for 3 seconds to assign the zone to “Input 1” on the QSE-IO. A flashing “Zone” LED indicates an assigned zone. To un-assign zones from the QSE-IO, press and hold the desired “Zone” button on the ESN for 3 seconds. The “Zone” LED will turn off to indicate the zone is unassigned. Zone Toggle Control A QSE-IO configured as a Zone Toggle Control can be used to toggle zones on your ESN using contact closure inputs into the QSE-IO, or to monitor the state (on or off) of the zones on your ESN using contact closure outputs out of the QSE-IO. To associate a QSE-IO that is set in a Zone Toggle configuration to an ESN(s): 1. Enter Zone Toggle Setup. Press and hold the “Prog” button on the QSE-IO for 3 seconds. The first output LED will flash indicating “Input 1” is selected. The sensor “Type” LEDs on the ESN(s) will scroll sequentially through each input type. A flashing “Zone” LED indicates an assigned zone. To un-assign zones from the QSE-IO, press and hold the desired “Zone” button on the ESN for 3 seconds. The “Zone” LED will turn off to indicate the zone is unassigned. buttons to adjust zone preset light levels. Note: If a zone is left off and is assigned, Scene Mode: Scene assignments are factory set. The top button is Scene 1, the bottom button is the Off Scene, and the Favorite button (if present) is Scene 2. Refer to Scene Setup to adjust zone levels for each scene. 3. Assign zones. Press and hold the “Zone” button of the desired zone for 3 seconds. A blinking “Zone” LED indicates an assigned Repeat steps 2-4 for each desired zone and QSE-IO input. 5. Exit Zone Toggle Setup. Press and hold the “Prog” button on the QSE-IO for 3 seconds to exit. Partition Control A QSE-IO configured as a Partition Control can be used to select scenes on your ESN using contact closure inputs into the QSE-IO, based on the status of movable walls. To associate a QSE-IO that is set in a Partition Control configuration to an ESN(s): 1. Enter Partition Control Setup. Press and hold the “Prog” button on the QSE-IO for 3 seconds. The first output LED will flash indicating “Input 1” is selected. The sensor “Type” LEDs on the ESN(s) will scroll sequentially through each input type. Repeat steps 2 and 3 for each desired zone-to-PicoR wireless controller assignment. 4. Exit PicoR wireless controller Assignment. Simultaneously press and hold the top and bottom buttons on the PicoR wireless controller for 3 seconds to exit. 2. Select input. Press the “Prog” button on the QSE-IO to select an input. Corresponding LED will blink. 3. Assign zones. Press and hold the desired “Zone” button on the ESN for 3 seconds to assign the zone to “Input 1” on the QSE-IO. A flashing “Zone” LED indicates an assigned zone. To un-assign zones from the QSE-IO, press and hold the desired “Zone” button on the ESN for 3 seconds. The “Zone” LED will turn off to indicate the zone is unassigned. Wired seeTouchR QS Wallstation Setup 1. Enter Wallstation Setup. Simultaneously press and hold the top and bottom buttons (excluding raise/lower) on the wallstation for LUTRON Sequencing Control 4. Assign zones. Press and hold the desired “Zone” button on the ESN for 3 seconds to assign the zone to “Input 1” on the QSE-IO. zone. A ”Zone” LED that is off indicates an unassigned zone. Figure F GRAFIK EyeR QS Control Unit / GRAFIK EyeR QS Timeclock Setup 2. Assign zones. Press and hold the desired “Zone” button on the ESN for 3 seconds to assign the zone to the QSE-IO. A flashing desired light level for the desired zone. Save the selected option. Press and hold the “Option” button for 3 seconds. The LED for the selected option will remain steady ON. Opt3 “Type” LEDs on the ESN(s) will scroll sequentially through each input type. 2. Select input. Press the “Prog” button on the QSE-IO to select an input. Corresponding LED will blink. 3. Set light levels. First press the “Zone” button for the zone you wish to setup, then use the and buttons on the ESN to set the Zone 1 Zone 2 Zone 3 Zone 4 www.lutron.com +44.(0)20.7702.0657 230 V~ 50 / 60 Hz 10 A Opt 1 To associate a QSE-IO that is set in a Scene configuration to an ESN(s): 1. Press and hold the “Prog” (Program) button on the QSE-IO for 3 seconds. The 5 output LEDs on the QSE-IO will cycle. The sensor 3. Exit Sequencing Control Setup. Press and hold the “Prog” button on the QSE-IO for 3 seconds to exit. Assigning Zones to PicoR Wireless Controllers (via QSM) Opt1 A QSE-IO configured as a Scene Selection Control can be used to change scenes on your ESN using contact closure inputs on the QSE-IO, or to monitor scene changes on your ESN using contact closure outputs on the QSE-IO. To associate a QSE-IO that is set in a Sequencing Control configuration to an ESN(s): Wireless Occupancy sensor: Press and hold the “Lights Off” or g button for 6 seconds, until the sensor’s dome begins to flash. The ESN will automatically select that input. Figure E Wired seeTouchR QS Wallstation Setup QSE-IO Input/Output Interface Setup 3. Exit Scene Selection Setup. Press and hold the “Prog” button on the QSE-IO for 3 seconds. Select wireless input: Press and hold 3 seconds QS Setup. Simultaneously press and hold the top and bottom buttons on the GRAFIK Eye® QS unit for 3 “Zone” LED indicates an assigned zone. To un-assign zones from the QSE-IO, press and hold the desired “Zone” button on the ESN for 3 seconds. The “Zone” LED will turn off to indicate the zone is unassigned. Press the “Prog” button to sequence through each associated input. The LED corresponding to the selected input will blink (other associated input LEDs will remain steady ON). Press and hold 3 seconds ® Scene Selection Control 1. Enter Program Mode. Press and hold the “Prog” (Program) button for 3 seconds. The “Prog” LED will blink once per second. The Press and hold 3 seconds indicates an assigned zone. To un-assign ESN zones from a GRAFIK Eye® QS unit, press and hold the desired “Zone” button on the ESN for 3 seconds. The “Zone” LED will turn off to indicate the zone is unassigned. The ESN can be associated to a QSE-IO that is configured as a scene selection control, sequencing control, zone toggle control, or a partition control. Refer to instrucitons below. Note: QSM must be assigned to ESN before assigning zones. See Section C. Opt3 2. Assign zones. Press and hold the desired “Zone” button on the ESN for 3 seconds to assign the zone. A flashing “Zone” LED Refer to the Installation Instructions provided with the QSE-IO for proper DIP switch settings. QS Sensor Module (QSM) Zone Assignment Assigning Zones to QSM Inputs (Occupancy, Daylight, IR) www.lutron.com +44.(0)20.7702.0657 230 V~ 50 / 60 Hz 10 A Press and hold 3 seconds Press and hold 3 seconds Set Zone Level Photo Occ Switch (Refer to Application Note 048447 for GRAFIK EyeR QS Remote Zone Mapping.) ® QS Setup. Simultaneously press and hold the top and bottom scene buttons on the GRAFIK Eye® QS unit for 3 seconds. The sensor “Type” LEDs on the ESN will scroll sequentially through each input type. seconds to exit. S3 CCI Zone 1 S4Zone 2Zone 1 Zone 2 Zone 3 Zone 4 Save Option QSNE-4A-D IR Photo Occ Switch Input S2 DIN Rail Power Module S1 Zone 1 Zone 2 Select Option Type QSNE-4A-D CCI DIN Rail Power Module 2. S4 buttons 4. Exit Wallstation Setup. Simultaneously press and hold the top and bottom buttons on the wallstation for 3 seconds to exit. 3. Exit GRAFIK Eye Press and hold 3 seconds 800 W Max 500 W Max800 W Max 500 W Max 500 W Max 500 W Max and 1. Enter GRAFIK Eye Press 3. Special Mode (Partitioning, Sequencing)* Refer to the Installation Instructions provided with the GRAFIK Eye® QS control unit or GRAFIK Eye® QS timeclock to set up time events. Press and hold 3 seconds Press and hold 3 seconds Press and hold 3 seconds IR Opt 3 GRAFIK Eye® QS Control Unit / GRAFIK Eye® QS Timeclock Setup 800 W Max 500 W Max 500 W Max 500 W Max S3 Scene “Zone” LED indicates an assigned zone. Zone 1 Zone 2 QSNE-4A-D DIN Rail Power Module Input S2 Opt 1 To un-assign ESN zones from a specific wallstation, press and hold the “Zone” button of the desired zone for 3 seconds. The “Zone” LED will turn off to indicate the zone is unassigned. Opt2 Type S1 Zone Toggle 3. Assign zones. Press and hold the “Zone” button of the desired zone for 3 seconds to assign the zone to the wallstation. A blinking L Option Def Exit Program Mode IR Photo Occ Switch 800 W Max 500 W Max 500 W Max 500 W Max Enter PicoR Wireless Controller Assignment Type Opt 2 Set zone levels (Zone Toggle only): First press the “Zone” button for the zone you wish to set up, then use the to adjust zone preset light levels. M Press and hold 3 seconds Press Press and hold 3 seconds Photo Occ Switch DIN Rail Power Module IR 1. Scene + off Assign zones to buttons (Zone Toggle only): To assign a specific ESN zone to a wallstation button, press the wallstation button you wish to assign. The button LED will blink slowly. H Zone 1 Zone 2 Zone 3 Zone 4 Type Zone 1 Zone 2 Zone 3 Zone 4 Def Save option: Press and hold the “Option” button for 3 seconds to save the wallstation type. The LED for the selected wallstation type will flutter for 1 second, then remain steady ON. 800 W Max 500 W Max 500 W Max 500 W Max 800 W Max 500 W Max 5. Option * Wallstation must already be set up as a Partitioning or Sequencing Control. If any other Wallstation Type is selected for an existing Special Mode wallstation, the wallstation is reprogrammed to the selected type, and cannot be re-selected as a Special Mode wallstation. Press and hold 3 seconds Press and hold 3 seconds Input Assign Zones LED Opt2 1. 4. Option Zone 1 Zone 2 Zone 3 Zone 4 Press Select Wireless: Select Daylight Sensor S1 LED Exit Scene Selection Setup Photo Occ Switch Input Press Press and hold 3 seconds Select Wireless: Select Occupancy Sensor 3. Assign Zones 800 W Max 500 W Max 500 W Max 500 W Max Zone 1 Zone 2 Type IR Photo Occ Switch DIN Rail Power Module IR DIN Rail Power Module Type 2. Enter Scene Selection Setup Input S1 Zone 1 Zone 2 QSNE-4A-D S1 1. 800 W Max 500 W Max Input Input DIN Rail Power Module 1. Wired seeTouchR QS Wallstation Setup - continued 3 seconds. The Sensor “Type” LEDs on the ESN(s) will scroll sequentially through each input type. Repeat steps 2 and 3 for each desired zone and QSE-IO input. 4. Exit Partition Control Setup. Press and hold the “Prog” button on the QSE-IO for 3 seconds to exit. Note: On wallstations with dual columns, each column is set up separately. 2. Select option. Press the “Option” button on the ESN to select the scene wallstation type. LED for currently saved type will remain steady ON. Continued next column... ® Lutron Electronics Co., Inc. | 7200 Suter Road Coopersburg, PA 18036-1299, U.S.A. Technical Assistance | 1.800.523.9466 USA, Canada, and the Caribbean | +44.(0)20.7702. 0657 Europe | +65.6220.4666 Asia | +.610.282.3800 Others | www.lutron.com Page 3 of 4 Figure H Occupancy Setup Occupancy Setup 800 W Max 500 W Max Input S1 Enter Zone Setup S2 2. S3 S4 Type IR DIN Rail Power Module Input S1 S2 S3 S4 CCI ZoneHi 1 Temp Zone 2 Type Prog Photo Occ Switch Input Hi Temp Prog Power Option Power Def QSNE-4A-D DIN Rail Power Module IR 3. Zone 1 Zone 2 Select Option 4. Select Zone Select Response Mode Photo Occ Switch 800 W Max 500 W Max Input CCI QSNE-4A-D 1. 800 W Max 500 W Max 500 W Max 500 W Max Option Def 2. Select “Def” (Default): Use the “Option” button to select “Def.” 3. Select Zone: Press the “Zone” button to select the zone you w)ant to change. 4. Select response. Use the and buttons to select the response type for each desired zone: M Opt2 L Opt3 Opt1 Opt2 Press Press Opt3 Press Press and hold 3 seconds 800 W Max 500 W Max Input S2 S3 S4 CCI Exit Zone Setup Input Hi Temp Prog Power Zone Response Type H Occupancy mode (auto on/off) M Vacancy mode (manual on/auto off) Opt1 Select Scene for Occupied State Opt2 Note: All zones use the same “Occupied Scene” and cannot be set on a zone-by-zone basis. All zones use the Off Scene for the unoccupied/vacant state. Opt3 800 W Max 500 W Max 2. Type IR CCI S2 S3 S4 CCI Input Zone 1 Zone 2 Hi Temp Photo Occ Switch Input Hi Temp Prog Power Power S1 S2 S3 S4 CCI Opt2 Zone 1 Zone 2 Prog Power QSNE-4A-D DIN Rail Power Module Hi Temp CCI Zone 1 Zone 2 Input Hi Temp Opt2 Prog Opt3 Power S2 View Scenes 5-16 Type Photo Occ Switch Opt1 S1 IR Option Def S3 S4 CCI Select Scene (Scenes 5-16) Photo Occ Switch Input Opt1 Hi Temp Opt2 Prog Opt3 Power Option Def Opt1 4. 2. Select Scene. Press the “Option” button to select a scene: S1 S2 IR Opt2 S3 S4 CCI Prog Power S3 CCI 2. Type Input CCI ZoneHi 1 Temp Zone 2 Type Prog Input Hi Temp Prog Power QSNE-4A-D Photo Occ Switch DIN Rail Power Module IR Opt2 S4 CCI 75% 3 50% 3 50% 4 25% 4 25% Scene # 800 W Max 500 W Max Option Power Def LED Pattern 5 Zone 1 Zone 2 3. Select Zone Press and hold the “Option” button for 10 seconds, then use the “Option” button to select a scene. = flashing Scene # = off 4. Default Level Scene # 100% 9 LED Pattern Default Level Scene # 100% 13 LED Pattern Default Level 6 H Zone 1 Zone 2 Zone 3 Zone 4 Opt1 Opt2 M Opt3 L 7 100% 100% 10 11 100% 100% 14 15 Prog Power Default Level Scene # 5 100% 6 LED Pattern Default Level Scene # LED Pattern Default Level 9 100% 13 100% 100% 10 100% 14 100% 7 100% 11 100% 15 100% 8 100% 12 100% 16 100% 100% Opt2 Press Press Press 8 100% 12 100% 16 100% 3. Set Occupied Scene. Press and hold the “Input” button for 3 seconds to set the currently selected scene as the Occupied Scene. The “Input” LED will turn on to indicate the selection is complete. 4. Exit Scene Setup Mode. Simultaneously press and hold the “Prog” and “Option” buttons for 3 seconds to exit. Zone 1 Zone 2 QSNE-4A-D DIN Rail Power Module Hi Temp = off 100% Photo Occ Switch Input LED Pattern = flashing 100% Set Zone Levels Opt1 Opt3 LED Legend: 800 W Max 500 W Max 500 W Max 500 W Max Option Def Type IR 2 LED Legend: 800 W Max 500 W Max S3 75% Opt3 Input S2 100% Press and hold the “Option” button for 10 seconds, then use the “Option” button to select a scene. Opt1 Exit Zone Setup S1 Default Level 1 Scenes 5-16 Press and hold 3 seconds 5. 2 LED Pattern = off Scenes 5-16 Option Def Select Option Photo Occ Switch DIN Rail Power Module IR S4 QSNE-4A-D S2 800 W Max 500 W Max S4 100% Zone 1 Zone 2 Input S3 1 Scene # = steady ON Press Press and hold 10 seconds Photo Occ Switch Input Opt3 Daylighting Setup S2 Default Level Type S1 S1 LED Legend: Opt3 Simultaneously Press and hold 3 seconds Input LED Pattern = off Input Opt1 Enter Zone Setup Scenes 1-4 = steady ON 800 W Max 500 W Max Option Def Press and hold 3 seconds 1. (Default) LED will be steady ON and the “Prog,” “Occ” (Occupancy Sensor), and “Switch” LEDs will blink once per second. Opt2 Exit Scene Setup Hi Temp Figure I Scene Setup 2. Select Scene. Press the “Option” button to select a scene: Scene # Zone 1 Zone 2 Repeat steps 3 and 4 for each zone. 5. Exit Zone Setup Mode. Simultaneously press and hold the “Prog” and “Input” buttons for 3 seconds to exit. 500 W Max Photo Occ Switch Input S4 Press Opt3 Type Occupied Scene Set IR IR S3 Opt1 Simultaneously Press and hold 800 W Max 3 seconds Input 3. Prog Option Def QSNE-4A-D DIN Rail Power Module IR Option Def DIN Rail Power Module S1 Type (Scenes 1-4) DIN Rail Power Module Input S2 Select Scene Type Photo Occ Switch 800 W Max 500 W Max Zone 1 Zone 2S1 QSNE-4A-D S4 DIN Rail Power Module S3 QSNE-4A-D Enter Scene Setup S2 QSNE-4A-D 1. Input S1 Zone Setup Mode. Simultaneously press and hold the “Prog” (Program) and “Input” buttons for 3 seconds. The “Prog,” “Def” (Default), “IR” (Infrared), and “Photo” (Daylight) LEDs will blink once per second. 1. Enter Scene Setup Mode. Simultaneously press and hold the “Prog” (Program) and “Option” buttons for 3 seconds. The “Def” Scenes 1-4 LED Legend: 800 W Max 500 W Max QSNE-4A-D Input 800 W Max 500 W Max Input DIN Rail Power Module Select Scene for Occupied State 1. Enter 1. Enter Scene Setup Mode. Simultaneously press and hold the “Prog” and “Option” buttons for 3 seconds. The “Input” and “Def” LEDs will be steady ON and the “Prog,” “Occ” (Occupancy Sensor), and “Switch” LEDs will blink once per second. Press and hold 3 seconds Set Daylight Sensor Setpoint zones, the minimum light level) that you wish to maintain in the space. 5. Exit Zone Setup Mode. Simultaneously press and hold the “Prog” and “Input” buttons for 3 seconds to exit. Option Def Daylighting setup should be performed during the daytime when there is consistent but indirect sunlight. Dark, cloudy days or days with highly variable cloud cover that frequently changes the sunlight conditions should be avoided. Additionally, times of day when the sunlight penetrates directly into the space should be avoided (such as morning or evening). 2. Select option. Use the “Option” button to select “Opt1” (Option 1) 3. Select Zone. Use the “Zone” button to select the zone to change. 4. Set light levels. Press the and buttons (cannot press and hold) to set the approximate light level (or, in the case of switched Repeat steps 3 and 4 for each desired zone. Photo Occ Switch QSNE-4A-D IR Flashing LED Zone 1 Zone 2 Type DIN Rail Power Module 5. S1 Set Zone Response to Occupancy Sensors 1. Enter Zone Setup Mode: Simultaneously press and hold the “Prog” (Program) and “Input” buttons for 3 seconds. The “Prog,” “Def” (Default), “IR” (Infrared), and “Photo” (Daylight) LEDs will blink once per second. H Zone 1 Zone 2 Zone 3 Zone 4 Opt1 Daylighting Setup Option Def 3. Select Zone: Press the “Zone” button to select the desired zone to change. 4. Set light levels. Use the and buttons to adjust the light level for the zone. To make a zone unaffected, press and hold the To make a zone affected again, press the on or flashing. button until only the “M” LED is steady ON. button until you see a combination of the “H,” “M,” and “L” LEDs steady Repeat steps 3 and 4 for each desired zone. 5. Exit Scene Setup Mode. Simultaneously press and hold the “Prog” and “Option” buttons for 3 seconds to exit. Opt1 Opt2 Opt3 Note: The fade time between scenes is factory set to 3 seconds, and is not adjustable. Press and hold 3 seconds 800 W Max 500 W Max IR Input S1 S2 S3 S4 CCI Type Hi Temp Prog Power QSNE-4A-D Input Option Def CCI 2. Photo Occ Switch Input Zone 1 Zone 2 Hi Temp Photo Occ Switch DIN Rail Power Module IR S4 Select Scene (Scenes 1-4) Prog Power Option Def 800 W Max 500 W Max Input S1 Zone 1 Zone 2 S2 S3 S4 CCI Photo Occ Switch Input Opt1 Hi Temp Opt2 Prog Opt3 Power S1 S2 View Scenes Type5-16 Type IR Zone 1 Zone 2 IR Option Def S3 S4 CCI Zone 1 Zone 2 Select Scene (Scenes 5-16) Photo Occ Switch Input Opt1 Hi Temp Opt2 Prog Opt3 Power QSNE-4A-D Type 800 W Max 500 W Max S3 QSNE-4A-D Enter Scene Setup S2 DIN Rail Power Module 1. 800 W Max 500 W Max Input S1 QSNE-4A-D Input DIN Rail Power Module Scene Setup DIN Rail Power Module Figure J Option Def Opt1 Opt2 Opt3 Opt1 Opt2 Press Press and hold 10 seconds Opt3 Press Simultaneously Press and hold 3 seconds 800 W Max 500 W Max 500 W Max 500 W Max 5. 4. Set Light Levels Exit Scene Setup 800 W Max 500 W Max Input H Zone 1 Zone 2 Zone 3 Zone 4 S1 S2 IR L Input Prog Press ® S4 CCI Zone 1 Zone 2 Photo Occ Switch Hi Temp Press S3 Type M Power QSNE-4A-D Select Zone DIN Rail Power Module 3. Option Def Simultaneously Press and hold 3 seconds Opt1 Opt2 Opt3 Lutron Electronics Co., Inc. | 7200 Suter Road Coopersburg, PA 18036-1299, U.S.A. CONTACT INFORMATION World headquarters European headquarters Asian headquarters Technical hotlines United States United Kingdom Singapore France: 0800.90.12.18 Lutron Electronics Co., Inc. Lutron EA Ltd. Lutron GL Ltd. Germany: 00800.5887.6635 7200 Suter Road 6 Sovereign Close 15 Hoe Chiang Road, Italy: 800.979.208 Coopersburg, PA 18036-1299 USA London, E1W 3JF UK #07-03 Tower Fifteen, Spain: 900.948.944 TEL +1.610.282.3800 TEL +44.(0)20.7702.0657 Singapore 089316 Northern China: 10.800.712.1536 FAX +1.610.282.1243 FAX +44.(0)20.7480.6899 TEL +65.6220.4666 Southern China: 10.800.120.1536 Technical Support 1.800.523.9466 Technical support FAX +65.6220.4333 Hong Kong: 800.901.849 +44.(0)20.7680.4481 Singapore: 800.120.4491 FREEPHONE 0800.282.107 Taiwan: 00.801.137.737 Thailand: 001.800.120.665853 Other Areas in Asia: +65.6220.4666 Technical Assistance | 1.800.523.9466 USA, Canada, and the Caribbean | +44.(0)20.7702. 0657 Europe | +65.6220.4666 Asia | +.610.282.3800 Others | www.lutron.com Page 4 of 4