OSRNA All Purpose Self-Regulating Heating Cable ELSR-NA BOT AO Features Outer jacket •Thermoplastic (AO, BO), Fluoropolymer (BOT). •Class III, T6. •Class I, Zone 1, AEx / Exe II, T6. •Class 1, Division 1, Groups B, C, D (Contact manufacturer). Bus wire •Nickel plated copper. Standards •CSA C22.2.130.03; -WS. •CAN/CSA 60079-7:12, 60079-0-11. •ANSI/IEEE 515, 515. Minimum start-up temperature •-30 °C (-22 °F). Maximum operating temperature (power on) •60 °C (140 °F). Maximum operating temperature (power off) •80 °C (176 °F). Certification •IECEx EPS 12.0006U. •12ATEX1431U. •CSA C US 2547790 Nominal voltage •120V, 240V. Rating •Wet rated, for outdoor use (WS). Bending radius, minimum •25 mm (1 in.). Warranty •1-year basic warranty on the heating cable. •10-year limited warranty available. Installation temperature, minimum •AO, BO: -45 °C (-49 °F). •BOT: -25 °C (-13 °F). Application •Freeze protection, heat tracing instrumentation, pipes, vessel and tanks, chemical and petrochemical industries, food processing, automotive, roof and gutter, sprinkler systems. Classification •II 2G Ex e IIC T6 Gb II 2D Ex tb IIIC. •T 80 °C Db. •Class I, Division 2, Groups A, B, C, D. •Class II, Division 2, Groups E, F, G. Models Nominal Output W/ft. Product #1 120V Product #1, 2 240V Outer jacket/Mechanical shield AO Price BO Price BOT Price Cable dimension approx. (mm) 1000 ft. spool 3 ELSR-NA-3-1-XX-10 ELSR-NA-4-2-XX-10 3 4250.00 3 4750.00 3 6750.00 13.8 x 5.6 5 ELSR-NA-5-1-XX-10 ELSR-NA-6-2-XX-10 3 4250.00 3 4750.00 3 6750.00 13.8 x 5.6 8 ELSR-NA-7-1-XX-10 ELSR-NA-8-2-XX-10 3 4250.00 3 4750.00 3 6750.00 14.1 x 5.6 10 - ELSR-NA-10-2-XX-10 3 4250.00 3 4750.00 3 6750.00 14.1 x 5.6 500 ft. spool 3 ELSR-NA-3-1-XX-05 ELSR-NA-4-2-XX-05 3 2275.00 3 2550.00 3 3625.00 13.8 x 5.6 5 ELSR-NA-5-1-XX-05 ELSR-NA-6-2-XX-05 3 2275.00 3 2550.00 3 3625.00 13.8 x 5.6 8 ELSR-NA-7-1-XX-05 ELSR-NA-8-2-XX-05 3 2275.00 3 2550.00 3 3625.00 14.1 x 5.6 10 - ELSR-NA-10-2-XX-05 3 2275.00 3 2550.00 3 3625.00 14.1 x 5.6 Cut to length3 3 ELSR-NA-3-1-XX ELSR-NA-4-2-XX 3 5.00 3 5.50 3 8.00 13.8 x 5.6 5 ELSR-NA-5-1-XX ELSR-NA-6-2-XX 3 5.00 3 5.50 3 8.00 13.8 x 5.6 8 ELSR-NA-7-1-XX ELSR-NA-8-2-XX 3 5.00 3 5.50 3 8.00 14.1 x 5.6 10 - ELSR-NA-10-2-XX 3 5.00 3 5.50 3 8.00 14.1 x 5.6 1 XX = Outer jacket/Mechanical shield. AO Aluminum foil and a thermoplastic outer jacket. BO Protective braid and a thermoplastic outer jacket. BOT Protective braid and a fluoropolymer outer jacket. 2 For operations at 208V, please consult Correction Factors/Multipliers at next page. 3 Cut to lenght service. When ordering, the quantity on the purchase order is equal to the lenght in feet of cable required. E.g.: To order 35 ft., write 35 for quantity with cut to lenght product code. Products Catalog 2016-2017 • www.ouellet.com 47 OSRNA Heating circuit length for ELSR-NA models 120V Start-up temperature CB capacity (A) ELSR-NA3-1 159 238 317 397 476 555 612 143 215 287 358 430 502 573 130 195 260 325 390 455 520 110 165 220 275 330 385 440 10 15 20 25 30 35 40 10 15 20 25 30 35 40 10 15 20 25 30 35 40 10 15 20 25 30 35 40 10 °C (50 °F) 0 °C (32 °F) -10 °C (14 °F) -30 °C (-22 °F) 240V Maximum heating circuit (ft.) for ELSR-NA5-1 125 187 249 312 374 436 499 112 168 224 280 336 392 448 102 153 204 255 306 357 408 87 130 173 217 260 303 347 ELSR-NA7-1 82 123 164 205 246 287 328 75 113 151 188 226 264 301 69 104 139 173 208 243 277 60 90 120 150 180 210 240 Start-up temperature Maximum heating circuit (ft.) for CB capacity (A) ELSR-NA4-2 273 410 547 683 820 957 1087 245 367 489 612 734 856 979 222 333 444 555 666 777 888 187 280 373 467 560 653 747 10 15 20 25 30 35 40 10 15 20 25 30 35 40 10 15 20 25 30 35 40 10 15 20 25 30 35 40 10 °C (50 °F) 0 °C (32 °F) -10 °C (14 °F) -30 °C (-22 °F) ELSR-NA6-2 170 255 340 425 510 595 857 154 231 308 385 462 539 616 141 211 281 352 422 492 563 120 180 240 300 360 420 480 ELSR-NA8-2 127 191 255 318 382 446 509 117 175 233 292 350 408 467 108 162 216 270 324 378 432 93 140 187 233 280 327 373 Maximum heating circuit ELSR-NA-XX on the following conditions: • 120/240 Voltage • Voltage drop max. 10% • MCB type QO (100% utilization) • Single cable fed 1 end ELSR-NA-XX-2-XX output ELSR-NA-XX-1-XX output (on insulated metallic pipes) (on insulated metallic pipes) 16 12 14 10 12 ELS R-N A-7 -1.. . ELSR -NA -5-1 ... ELSR -NA-3 -1... 6 4 2 – 30 (-22) – 20 (-4) – 10 (14) 10 Output (W/ft.) Output (W/ft.) 8 8 6 4 ELS R-N A-1 0-2 ELSR ... -NA ELSR -8-2... -NA -6-2 ... ELSR -NA-4 -2... 2 0 (32) 10 (50) 20 (68) 30 (86) 40 (104) 50 (122) 60 (140) – 30 (-22) – 20 (-4) – 10 (14) 0 (32) 10 (50) 20 (68) 30 (86) 40 (104) 50 (122) Pipe temperature °C (°F) Pipe temperature °C (°F) Eltherm® Correction Factors/Multipliers for Operation of Heating Cables in 208V To calculate the corrected power output for operation in 208V, multiply the published output at 240V (in W/ft.) by the nominal output factor provided for the applicable heating cable type. To calculate maximum heating circuit lengths for operation in 208V (tables provided in product data sheets), multiply the published max. heating circuit length at 240V provided for the applicable heating cable type. 48 Heating Cable Correction Factors/ Multipliers ELSR-NA-XX-2 Products Catalog 2016-2017 • www.ouellet.com Nominal Output 208V vs. 240V 0.88 Heating Circuit Length 208V vs. 240V 0.93 60 (140) ELSR-NA10-2 66 99 132 165 198 231 264 61 91 121 152 182 212 243 57 85 113 142 170 198 227 50 75 100 125 150 175 200 OSRNA, OSRMA, OSRWA, OSRHA Options Product # ELSR-NA Models EL-ECN-EX1 ELVB-SRAN ELVB-SRAN-3/4-ST ELSR-KIT-NA ECA-JB1-NA ECA-JB2-NA ELVB-SREX-3/4-HT1 ELVB-SREX-M20-HT1 ELSR-MA Models EL-ECM1 ELVB-SRAM-3/4-ST ELSR-KIT-MA ELVB-SRAM ELSR-MA-BF Models EL-ECMF2 ELVB-SRAM-3/4-ST ECA-MABF-PH-1 ECA-MABF-PH-11/4 ECA-MABF-PH-11/2 ELSR-KIT-MA-BF FIT-BF ELSR-WA Models EL-ECW1 ELVB-SRAW-3/4-ST ELSR-KIT-WA ELVB-SRAW ELSR-HA Models ELVB-SRAH-3/4-ST ELVB-SRAH EL-ECH-EX1 ELSR-KIT-HA ECA-JB1-HA ECA-JB2-HA ELVB-SREX-3/4-HT1 ELVB-SREX-M20-HT1 All ELSR Models Multiple applications ECA-TYS6-280 ECA-TYS9-280 ECA-TYS12-280 ECA-TYS18-280 ECA-TYS24-280 EL-WS03 Roof ang gutter ELB-18 ELB-20 ELB-21 ELB-RCLIP Pipe tracing ELB-16-10 ELB-16-20 ELB-16-36 ELB-03 ELB-06C 1 2 Price Factory Installed Description Kit 18.00 35.00 60.00 69.00 265.00 375.00 160.00 150.00 End termination for ELSR-NA Power connection without cable gland Power connection with steel/zinc cable gland/fitting, 3/4'' NPT, non-hazardous location End and power termination kit with warning sticker NA Series Junction box with power connection and termination for single connection c/w label and fastener Junction box with power connection and termination for double connectionc/w label and fastener Power connection with brass cable gland, 3/4'' NPT, hazardous location Power connection with brass cable gland, M20, hazardous location - 3 3 3 3 3 3 3 3 18.00 60.00 69.00 35.00 End termination for ELSR-MA Power connection with steel/zinc cable gland/fitting, 3/4'' NPT, non-hazardous location End and power termination kit with warning sticker MA Series Power connection without cable gland - 3 3 3 3 25.00 60.00 65.00 85.00 115.00 77.50 36.00 End termination for ELSR-MA-BF Power connection with steel/zinc cable gland/fitting, 3/4'' NPT, non-hazardous location Quick connect plumbing kit for 1'' polyethylene pipes Quick connect plumbing kit for 1 1/4'' polyethylene pipes Quick connect plumbing kit for 1 1/2'' polyethylene pipes End and power termination kit with warning sticker BF Series Brass gland cable fitting 3/4’’ NPT non-hazardous location for MA-BF cable - 3 3 3 3 3 3 3 18.00 65.00 74.00 40.00 End termination for ELSR-WA Power connection with steel/zinc cable gland, 3/4'' NPT, non-hazardous location End and power termination kit with warning sticker WA Series Power connection without cable gland - 3 3 3 3 60.00 35.00 18.00 69.00 265.00 375.00 160.00 150.00 Power connection with steel/zinc cable gland/fitting, 3/4'' NPT, non-hazardous location Power connection without cable gland End termination for ELSR-HA End and power termination kit with warning sticker HA Series Junction box with power connection and termination for single connection c/w label and fastener Junction box with power connection and termination for double connectionc/w label and fastener Power connection with brass cable gland, 3/4'' NPT, hazardous location Power connection with brass cable gland, M20, hazardous location - 3 - 3 3 3 3 3 3 10.00 11.00 13.00 15.00 18.00 2.00 Stainless steel fastener 1/4'' x 6'' (6.8 mm x 152.4 mm) Stainless steel fastener 1/4'' x 9'' (6.8 mm x 228.6 mm) Stainless steel fastener 1/4'' x 12'' (6.8 mm x 304.8 mm) Stainless steel fastener 1/4'' x 18'' (6.8 mm x 457.2 mm) Stainless steel fastener 1/4'' x 24'' (6.8 mm x 609.6 mm) Warning label/sign bilingual (English / French) - 3 3 3 3 3 3 8.00 12.00 13.00 35.00 Gutter and downspout mounting plate Downspout mounting plate Gutter mounting plate Roof clips for cable, qty 25 - 3 3 3 3 7.00 9.00 15.00 45.00 35.00 Mechanical fastener, plastic strap (L 102 mm x 2.5 mm) Mechanical fastener, plastic strap (L 200 mm x 3.6 mm) Mechanical fastener, plastic strap (L 360 mm x 4.8 mm) Self-adhesive glass fiber tape, max. temp. = 90 °C (194 °F), 50 m (165 ft.) Self-adhesive aluminum tape, max. temp. = 80 °C (176 °F), 50 m (165 ft.) - 3 3 3 3 3 Minimum installation temperature -45 °C (-49 °F). Minimum installation temperature -13 °C (-25 °F). EL-EC(x) ELVB-SRA(x) ELVB-SRA(x)-3/4-ST ECA-JB1 Products Catalog 2016-2017 • www.ouellet.com ELSR-KIT-(xx) 55 OSRNA, OSRMA, OSRWA, OSRHA Controls Product # Price Description Controller options for pipe tracing for use in non-hazardous (ordinary) locations ECA-E55-R25HT1 725.00 SPDT, NEMA 4X thermostat in molded aluminum housing, 22A at 120/250/480V, with 10 ft. (3 m) stainless steel bulb and capillary TPR-L1N-3X-Q101 395.00 SPDT, NEMA 4X thermostat in polycarbonate housing, 22A at 120/250/480V, with 10 ft. (3 m) tinned copper bulb and capillary SPDT, NEMA 4X thermostat, range -17 °C to 49 °C (0 °F to 120 °F), 25A at 120/208/240/277V, with 5 ft. (1.5 m) stainless bulb 135.00 TRF115-005 and capillary SPDT, NEMA 4X thermostat, range -35 °C to 38 °C (-30 °F to 100 °F), 25A at 120/208/240/277V, with 8 ft. (2.4 m) copper bulb 140.00 TRF115-0071 and capillary Controller options for roof and gutter for de-icing DS-2C1 471.00 Aerial mounted controller with sensors to detect humidity and temperature, 30A, 100V to 277V Aerial mounted controller with a sensor to detect temperature and a sensor to detect humidity with 10 ft. (3 m) cable, 1 575.00 DS-8C 30A, 100V to 277V Aerial mounted controller with a sensor to detect temperature and a sensor to detect humidity with 10 ft. (3 m) cable, 590.00 DS-9C1 2 X 30A, 100V to 277V EX-50 205.00 50 ft. (15 m) extension kit, with connection fittings for humidity sensor 1 CDP-2 195.00 Interior controller and display for DS products 524.00 Dual-zone electronic controller, 3 X 16A, 120V to 240V ETO21 ETF-744/99 169.00 24V outdoor sensor for measuring temperature ETOR-55 330.00 Gutter sensor to detect humidity with 33 ft. (10 m) cable Controller options for pipe tracing for use in non-hazardous (ordinary) and hazardous locations SPDT, explosion-proof, NEMA 4, 7 and 9 thermostat, in anodized aluminum housing, 22A at 120/250/480V, TXR-L2S-10-Q101 1275.00 with 10 ft. (3 m) stainless steel bulb and capillary TM-1SIH1-E5-RTD-A1 1385.00 TraceMateTM I GFCI electronic thermostat for single circuit at 120V TM-1DIH2-E5-RTD-A1 1575.00 TraceMateTM I GFCI electronic thermostat for single circuit at 208/240V TM-2SIH1-E5-RTD 2375.00 TraceMateTM II GFCI electronic thermostat for dual circuit at 120V TM-2DIH2-E5-RTD 3025.00 TraceMateTM II GFCI electronic thermostat for dual circuit at 208/240V MS-2101 2900.00 MasterTrace Single circuit electronic GFCI controller with double pole, 120V to 277V, 30A, with user interface MS-2102 3500.00 MasterTrace Double circuit electronic GFCI controller with single pole, 120V only, 30A, with user interface 1 Requires a ground fault circuit interrupter (GFCI) in the electrical panel. ECA-E55-R25HT DS-2C ETO2 56 TPR-L1N-3X-Q10 DS-8C ETF-744/99 TRF115-005 DS-9C ETOR-55 TRF115-007 EX-50 TXR-L2S-10-Q10 Products Catalog 2016-2017 • www.ouellet.com CDP-2 TraceMateTM MasterTrace