443561201320-B ECF Mounting

INSTALLATION INSTRUCTIONS
ECOFORM RETROFIT ARM MOUNT
IMPORTANT: READ ALL INSTRUCTIONS BEFORE PERFORMING ANY WORK. BE SURE ALL
POWER IS OFF PRIOR TO INSTALLING LUMINAIRES.
FIG. 2
FIG. 1
1.
2.
3.
4.
5.
6.
7.
8.
9.
FIG. 3
ATTACH CAGE NUTS TO BOLSTER PLATE, (SEE FIGURE 1), AND SLIDE BOTTOM CAGE NUT TO
APPROXIMATE HOLE MOUNT SPACINGS.
LOCATED ON THE BOTTOM OF THE LUMINAIRE ARM ASSEMBLY, LOOSEN (2) #8-32 SCREWS. OPEN ARM
ASSEMBLY, (SCREWS ARE CAPTIVE AND WILL REMAIN ON DOOR).
INSTALL LUMINAIRE TO MIDDLE THREADED HOLE ON RETROFIT ADAPTER USING 3/8-16 HEX HEAD BOLT
AND LOCKWASHER.
TIGHTEN ALL MOUNTING BOLTS TO 18 FT-LBS.
NOTE FOR SQUARE POLES: USE RUBBER SQUARE POLE ADAPTER.
INSERT BOLSTER PLATE INSIDE POLE, (SEE FIGURE 2). INSTALL LOCKWASHER TO LONGEST 3/8-16 HEX
HEAD BOLT, INSERT THROUGH TOP HOLE OF LUMINAIRE, AND THREAD INTO TOP CAGE NUT OF BOLSTER
PLATE.
REMOVE (2) #6 FLAT HEAD SCREWS BELOW RETROFIT COVER PLATE. INSTALL LOCKWASHER TO FINAL
3/8-16 HEX HEAD BOLT, INSERT INTO BOTTOM SLOT OF RETROFIT ADAPTER, AND THREAD INTO BOTTOM
CAGE NUT. REPLACE RETROFIT
COVER PLATE.
CONNECT SUPPLY AND GROUND WIRES TO LUMINAIRE LEAD WIRES. MAKE WIRE CONNECTIONS PER NEC
OR APPLICABLE LOCAL CODES.
SECURE SUPPLY WIRES WITH CABLE TIE, (STRAIN RELIEF), IN THE ARM.
CLOSE ARM DOOR AND SECURE WITH THE TWO CAPTIVE #8-32 SCREWS.
ENERGIZE LUMINAIRE TO TEST INSTALLATION.
© 2013 Koninklijke Philips N.V. (Royal Philips). All rights reserved.
www.philips.com/luminaires
44356121320 Rev. B
Page 1 of 5
INSTALLATION INSTRUCTIONS
ECOFORM SURFACE CONDUIT MOUNT
IMPORTANT: READ ALL INSTRUCTIONS BEFORE PERFORMING ANY WORK. BE SURE ALL
POWER IS OFF PRIOR TO INSTALLING LUMINAIRES.
NOTE: WALL MOUNTING BRACKET IS SECURED TO WALL WITH 3/8” STUDS
OR BOLTS, (BY OTHERS). STRUCTURAL MEMBERS MUST BE
PRESENT IN WALL TO ACCEPT BOLTS.
MOUNTING HOLE PATTERN
© 2013 Koninklijke Philips N.V. (Royal Philips). All rights reserved.
www.philips.com/luminaires
443561201320 Rev. B
Page 2 of 5
INSTALLATION INSTRUCTIONS
ECOFORM MAST ARM MOUNT
IMPORTANT: READ ALL INSTRUCTIONS BEFORE PERFORMING ANY WORK. BE SURE ALL
BE SURE ALL POWER IS OFF PRIOR TO INSTALLING LUMINAIRES.
1.
2.
3.
4.
BOLT LUMINAIRE TO MAST ADAPTER WITH 3/8” BOLTS AND LOCKNUTS.
SLIP LUMINAIRE OVER THE MAST ARM, (BY OTHERS).
LEVEL LUMINAIRE, (SIDE BY SIDE), AND TIGHTEN (4X) 3/8”-16 SET SCREWS.
PULL SUPPLY AND GROUND WIRES TO LUMINAIRE AND CONNECT THE
WIRES TO LUMINAIRE LEADS. MAKE WIRE CONNECTIONS PER NEC OR
APPLICABLE CODES.
© 2013 Koninklijke Philips N.V. (Royal Philips). All rights reserved.
www.philips.com/luminaires
443561201320 Rev. B
Page 3 of 5
INSTALLATION
INSTRUCTIONS
ECOFORM LUMINAIRE MOUNTED ON PTF2 (3-1/2” O.D.),
PTF3 (4-1/2” O.D.) OR PTF4 (5” O.D.) POLE TOP FITTER
IMPORTANT: READ ALL INSTRUCTIONS BEFORE PERFORMING ANY WORK. BE SURE ALL
POWER IS OFF PRIOR TO INSTALLING LUMINAIRES.
1.
LOCATED ON THE BOTTOM OF THE ARM ASSEMBLY, LOOSEN (2) #8-32 SCREWS USING PHILLIPS HEAD SCREWDRIVER.
OPEN ARM ASSEMBLY, (SCREWS ARE CAPTIVE AND WILL REMAIN ON DOOR).
2. APPLY A BEAD OF SUITABLE WEATHERPROOF SEALANT HORIZONTAL, TOP, VERTICAL, LEFT AND RIGHT EDGES OF
ARM WHERE IT CONTACTS THE POLE TO PREVENT WATER ENTRY.
3. ATTACH LUMINAIRE/ARM ASSEMBLY TO POLE TOP FITTER BY LINING UP THE THREADED HOLE ON POLE TOP FITTER
TO BOTTOM HOLE ON ARM, (SEE FIGURE 4).
4. THREAD THE BOTTOM 3/8” BOLT AND LOCK WASHER INTO THE LOWER TAPPED HOLE OF THE POLE TOP FITTER FROM
INSIDE OF ARM ASSEMBLY AND TIGHTEN.
NOTE FOR POLE TOP FITTERS GREATER THAN 4 INCH O.D.: INSERT PROVIDED SHIMS BETWEEN POLE AND LUMINAIRE,
(TOP AND BOTTOM BOLT), ENSURING THERE IS STILL A METAL TO METAL CONTACT BETWEEN POLE AND LUMINAIRE.
ON LEFT AND RIGHT, (LUMINAIRE SHOULD NOT SWAY LEFT OR RIGHT WHEN BOLTS ARE TIGHTENED).
5. NUT INSIDE FITTER, THEN HOLD. THREAD THE TOP 3/8” BOLT AND LOCK WASHER THROUGH POLE TOP FITTER FROM
INSIDE OF ARM ASSEMBLY AND TIGHTEN.
TORQUE ALL NUTS TO APPROXIMATELY 18 FT-LBS.
6. INSTALL THE POLE TOP FITTER/LUMINAIRE ONTO THE TENON. TOP OF THE TENON MUST SEAT AGAINST THE FITTER
STOP. LEVEL AND SECURE WITH (8) 3/8” SOCKET SET SCREWS.
7. ROUTE SUPPLY AND GROUND WIRES OVER THE STRAIN RELIEF ROD. TIE OFF WITH TAPE OR WIRE TIE AS SHOWN.
8. CONNECT FIELD SUPPLY AND GROUND WIRES TO LUMINIAIRE LEADS. MAKE WIRE CONNECTIONS PER NEC OR
APPLICABLE LOCAL CODES.
9. INSTALL POLE TOP FITTER CAP AND SECURE INPLACE WITH (2) #10-32 PHILLIPS PAN HEAD SCREWS.
10. CLOSE ARM ASSEMBLY AND SECURE WITH THE (2) 8-32 SCREWS.
11. ENERGIZE LUMINAIRE TO TEST INSTALLATION.
© 2013 Koninklijke Philips N.V. (Royal Philips). All rights reserved.
www.philips.com/luminaires
443561201320 Rev. B
Page 4 of 5
INSTALLATION
INSTRUCTIONS
ECOFORM LUMINAIRE MOUNTED ON PTF2 (3-1/2” O.D.),
PTF3 (4-1/2” O.D.) OR PTF4 (5” O.D.) POLE TOP FITTER
IMPORTANT: READ ALL INSTRUCTIONS BEFORE PERFORMING ANY WORK. BE SURE ALL
POWER IS OFF PRIOR TO INSTALLING LUMINAIRES.
FIG. 4
TENON HEIGHT
POLE WITH TENON
(SEE TABLE)
© 2013 Koninklijke Philips N.V. (Royal Philips). All rights reserved.
www.philips.com/luminaires
443561201320 Rev. B
Page 5 of 5
FITTER
TYPE
PTF2
PTF3
PTF4
“X”
DIA. (Ø)
3-1/2”
4-1/2”
5”
Philips Lighting Company
200 Franklin Square Drive
Somerset, NJ 08873
Phone: 855-486-2216
USED ON TENON SIZE
2-3/8” TO 2-7/8” O.D. X 4” HIGH
3” TO 3-1/2” O.D. X 6” HIGH
3-1/2” TO 4” O.D. X 6” HIGH
Philips Lighting Company
281 Hillmount Road
Markham ON, Canada L6C 2S3
Phone: 855-486-2216