www.sylvania.com QUICKTRONIC® T8 Instant Start Universal Voltage Systems Lamp Striation Control Low Ballast Factor Q HE T8 ISL High Efficiency Series Lamp / Ballast Guide 32W T8 – OCTRON lamps 1-lamp QHE1x32T8/UNV ISL-SC 2-lamp QHE2x32T8/UNV ISL-SC 3-lamp QHE3x32T8/UNV ISL-SC 4-lamp QHE4x32T8/UNV ISL-SC ® Also operates: FBO32, FBO31, FO25, FBO24, FO17, FBO16, FO30/SS (30W), FBO30/SS (30W), FBO29/SS (29W), FO28/SS (28W) & FO25/SS (25W) FO40T8 operation: 1 lamp on 2L ballast; 2 lamps on 3L ballast; 3 lamps on 4L ballast Key System Features • H igh Efficiency Systems over 90% efficient •NEMA Premium Electronic Ballast Program compliant •Lamp Striation Control (LSC) •Over 100 LPW (lumens/watt) with OCTRON SUPERSAVER® lamps •Lowest power T8 I.S. Systems •Universal voltage (120-277) •Small Can enclosure size •30-50% Energy savings •Min. Starting Temp: • -20°F (-29°C) for T8 lamps • 60°F (16°C) for Energy Saving T8 lamps • 0°F (-18°C) for FO40T8 lamps •<10% THD •Virtually eliminates lamp flicker •RoHS compliant •Lead-free solder and manufacturing process Application Information SYLVANIA QUICKTRONIC High Efficiency ballasts are ideally suited for: •Any applications where the lowest power T8 systems are needed for maximum energy savings •Energy Retrofits •Commercial & Retail •Hospitality & Institutional •New Construction ECS401 - 6-13 SYLVANIA QUICKTRONIC High Efficiency, (QHE) energy-saving electronic T8 ballasts offer several advantages: 1. Same Light, Less Power! • Up to 6% in energy savings compared to standard T8 low power electronic ballasts without compromising light output •M aximum energy savings when compared to F40T12 magnetically ballasted systems 2. Parallel Circuitry: keeps remaining lamps lit if one or more go out. 3. Lamp Striation Control (LSC): T8 energy saving lamps should be operated above 60°F, but under certain conditions the lamps may striate. LSC circuitry may minimize or eliminate this condition; however there are limited applications where LSC circuitry may not entirely mitigate lamp striations 4. NEMA Premium Electronic Ballast Program compliant. The program promotes the use of high efficiency T8 electronic ballasts by meeting or exceeding the Ballast Efficiency System Information SYLVANIA QUICKTRONIC High Efficiency (QHE) System advantages: • Operate from 120V through 277V • Eliminates “wrong voltage” errors • Reduces inventory by 50% • Utilizes Instant Start operation for • Highest System Efficacy • Low temperature starting capability Factors, (BEF) established by the CEE, (Consortium for Energy Efficiency). For additional information on this program go to: www.cee1.org or www.nema.org These ballasts are also RoHS compliant and feature lead-free solder and manufacturing process. SYLVANIA QUICKTRONIC High Efficiency (QHE) systems are covered by the QUICK 60+® warranty, the first and most comprehensive lamp & ballast system warranty in the industry. 5. New Banded Packaging •D istributor-friendly for easy stocking and individual ballast sales •R educed waste • E asy removable bands •N o tangled wires Relative Input InitialSystemMean Mean System Type Power System Efficacy System Light Energy (2-lamp) (W) Lumens LPW LumensOutputSavings F34T12 - E.S. Magnetic Ballast 72 4660 65 3960 FO32/XP - QHE2x32T8/UNV ISL-SC FO28/SS - QHE2x32T8/UNV ISL-SC 48 42 4680 4250 98 101 4440 3995 ® Baseline Baseline 112% 101% % Relative Light Output (Mean Lumens) 120% • Very low harmonic distortion (<10%)THD 110% • Operate at >42 kHz to reduce potential interference with infrared control systems 100% % System Wattage (Power) 112% 101% 100% 100% 90% 80% 33% Energy Savings 70% 67% 60% 42% Energy Savings 58% 50% 40% 2-F34T12/SS E.S. Magnetic Ballast 2-FO32/XP/ECO QHE 2x32T8/UNV ISL 2-FO28/SUPERSAVER QHE 2x32T8/UNV ISL 33% 42% Catalog # Date Project Prepared by High Efficiency Comments Item OSRAM SYLVANIA Number Description 49837 QHE1X32T8/UNV ISL-SC 2600 3000 2850 2725 2475 1 1 1 1 1 0.78 0.78 0.78 0.78 0.78 2030 2340 2225 2125 1930 1865 2200 2090 2000 1815 25 25 24 22 20 81 94 93 97 97 3.12 3.12 3.25 3.55 3.90 0.41/0.18 FO32/700 0.41/0.18 FO32/XP 0.38/0.16 FO30/SS 0.35/0.15 FO28/SS 0.32/0.14 FO25/SS 2600 3000 2850 2725 2475 2 2 2 2 2 0.78 0.78 0.78 0.78 0.78 4055 4680 4445 4250 3860 3730 4400 4180 3995 3630 48 48 45 42 38 84 98 99 101 102 1.63 1.63 1.73 1.86 2.05 QHE3X32T8/UNV ISL-SC Banded Pack 4986510-Pack 0.61/0.27 FO32/700 0.61/0.27 FO32/XP 0.58/0.25 FO30/SS 0.53/0.23 FO28/SS 0.48/0.21 FO25/SS 2600 3000 2850 2725 2475 3 3 3 3 3 0.78 0.78 0.78 0.78 0.78 6085 7020 6670 6380 5790 5595 6600 6270 5995 5445 73/72 73/72 68 63 57 83/85 96/98 98 101 102 1.08 1.08 1.15 1.24 1.37 49840 0.80/0.35 FO32/700 0.80/0.35 FO32/XP 0.75/0.32 FO30/SS 0.71/0.31 FO28/SS 0.62/0.27 FO25/SS 2600 3000 2850 2725 2475 4 4 4 4 4 0.78 0.78 0.78 0.78 0.78 8110 9360 8890 8500 7720 7455 8800 8360 7990 7260 95 95 89 84 76/75 85 99 100 101 102/103 0.82 0.82 0.88 0.93 1.04 49838 QHE2X32T8/UNV ISL-SC Banded Pack 4986310-Pack 49839 QHE4X32T8/UNV ISL-SC Banded Pack 4986710-Pack Banded Pack, (add “-B” to Description). Banded Pack and 10-Pack contain 10 pieces each. 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). Black/White White Black/White Blue Blue Black/White Black Blue BALLAST White White Black White Red Blue BALLAST BALLAST Blue Blue Blue Black White Red Black Black BALLAST White White Red Red Specifications Data based on F32T8 Starting Method: Instant Start Ballast Factor: 0.78 Circuit Type: Parallel Lamp Frequency: >42 kHz Lamp CCF: Less than 1.7 Starting Temp:2 -20°F (-29°C) for OCTRON T8 lamps; 60°F (16°C) for SUPERSAVER® T8 lamps 0°F (-18°C) for FO40T8 Input Frequency: 50/60 Hz Low THD: <10% Power Factor: >98% Black Blue Voltage Range: ±10% of 120-277V White Blue Blue Blue Blue Blue rated line (108-305V) Red BALLAST Blue BALLAST BALLAST BALLAST White Blue LAMP Red LAMP QUICKTRONIC FM (2 L QUICKTRONIC FM (1below LAMP) 2 Operation 50°F (10°C) may affect Note: light For QT-FM green ground wire to termi LAMP green ground wire to terminal required. QUICKTRONICNote: FMFor(2QT-FM LAMP) QUICKTRONIC FM (1 LAMP) QUICKTRONIC FM (2orLAMP) QUICKTRONIC Note: For QT-FM green ground wire to terminal required.FM (1 LAMP) Note: For QT-FM green ground wire to terminal required.output lamp operation – see “Low Temp. LAMP LAMP LAMP LAMP cap any blue lead. Note: For two lamp application, LAMP lamp application, cap any two blue leads. Note:For Forone three lamp application, cap any unused blue lead. Note: For cap three lamp cap any unused blue lead. Insulate to 600 volts. For two lamp application, two blueapplication, leads individually. For twocap lamp application, For one lamp application, two blue leads,cap onetwo redblue and leads individually. QUICKTRONIC 3x32 For one lamp application, cap two one yellow lead individually. Insulate to 600 volts.blue leads, one red and one yellow lead individually. Insulate to 600 volts. White Green Black Product Weight: 1.6 lbs each (approx) Red Wiring: ONIC FM (1 LAMP) Blue Black Blue White LAMP BALLAST White Red YellowBALLAST Red LAMP Red Black White Red Blue Note: For QT-FM green ground wire to terminal required. QUICKTRONIC 4x32 Black White Red Black Blue Blue BlackBlue Blue BALLAST White Blue White BALLAST BALLAST Red Blue Black Blue BALLAST White Blue Black BALLAST Red White 8.7 mm Slot QUICKTRONIC FM (2 LAMP) Width White Red Blue Blue Blue Blue BALLAST Blue System Life / Warranty Red Mounting Length Height QUICKTRONIC products are covered by the QUICK 60+® warranty, a comprehensive lamp and ballast system warranty. For additional details, refer to the QUICK 60+ warranty bulletin. BALLAST Bl Bl Bl Length Note: For one lamp application, cap any blue lead. Insulate to 600 volts. Note: For one lamp application, cap any blue lead. Insulate to 600 volts. Note: For two lamp application, cap any blue lead. Insulate to 600 volts. Note: For one lamp application, cap any blue lead. Insulate to 600 volts. Note: For two lamp application, cap any blue lead. Insulate to 600 volts. QUICKTRONIC 1x40DL QUICKTRONIC 1x40DL 49838 QHE 2 x 32T8 / Black Blue Blue White Blue QUICKTRONIC PROFESSIONAL BALLAST Black Blue Red Blue Black BALLAST White Number of Lamps BALLAST White Red Item Number QUICKTRONIC 1x40DL QUICKTRONIC 2x40DL QUICKTRONIC 2x40DL UNV ISL - SC Blue Blue Red OSRAM SYLVANIA QUICKTRONIC 2x40DL QUICKTRONIC 3x40DL National Customer QUICKTRONIC 3x40DL Case Size Blue Black Starting/Ballast Factor Blue BALLAST White Black Blue Black Red Line Voltage (120-277V) Blue White White BALLAST Red Yellow Primary Lamp Wattage BALLAST Yellow Red Yellow Yellow LAMP LAMP SYLVANIA, the system solution, OCTRON, XP, SUPERSAVER, and QUICK 60+ areLAMP registered trademarks of OSRAM SYLVANIA Inc. LAMP LAMP SEE THE WORLD IN A NEW LIGHT is a trademark of OSRAM SYLVANIA Inc. QUICKTRONIC is a registered trademark of OSRAM GmbH. LAMP Note: For one lamp application, cap any unused blue lead. Insulate to 600 volts. LAMP on, cap any blue lead. Insulate to 600 volts. Starting” definition. 3 Complies with European Union Restriction of Hazardous Substances Directive (Directive EC 2002/95) Black Red Note: For QT-FM green ground wire to terminal required. Leads only (no connectors provided) en ground wire to terminal required. QT-FMapplication, green ground wire to terminal required. blue lead. Note: For Note: threeForlamp cap any unused For two lamp application, cap two blue leads individually. For one lamp application, cap two blue leads, one red and one yellow lead individually. Insulate to 600 volts. QUICKTRONIC 4x32 QUICKTRONIC 4x32 BALLAST Dimensions: Overall: 9.5" L x 1.68" W x 1.18" H Mounting: 8.90" Black Blue RedRed ©2013 OSRAM SYLVANIA TRONIC 2x32 TRONIC 2x40DL QHE Instant Start ballasts will operate F17, F25 and F32 (and the SUPERSAVER® & U-Bend equivalent) T8 lamps. Complete performance data is available in the QUICKSYSTEMS section of the SYLVANIA Ballast Technology & Specification Guide. UL Listed Class P, Type 1 Outdoor LAMP BALLAST Red LAMP CSA Certified Red LAMP LAMP LAMP 70°C Max Case Temperature LAMP LAMP LAMP LAMP LAMP LAMP LAMP FCC 47CFR Part 18 Non-Consumer LAMP LAMP LAMP LAMP LAMP LAMP Note: For two lamp application, cap Note: For one lamp application, any Rating blue lead. Class A cap Sound any blue lead.volts. Note: For one lamp application,QUICKTRONIC cap any blue lead. 1x32 Note: For two lamp application, cap For one lamp application, cap any tw Insulate to 600 3 lead. Note: Forcap twoany lamp cap any blue Note:to For one lamp application, cap any blueFor lead. RoHS QUICKTRONIC 1x32 one lamp application, twoapplication, blue leads.Compliant Insulate 600 volts. Insulate to 600 volts. QUICKTRONIC 1x32 For one lamp application, cap any 2x32 two blue leads. QUICKTRONIC Insulate to 600 volts. Insulate to 600 volts. NEMA Premium Electronic Ballast QUICKTRONIC 3x QUICKTRONIC 2x32 Insulate to 600 volts. QUICKTRONIC 2x32 QUICKTRONIC 3x32 Program compliant QUICKTRONIC 3x32 ANSI C62.41 Cat. A Transient Protection Black Blue Black Blue White Blue White GFCI compatible White Black Blue Green BALLAST White Blue White Green BALLAST BALLAST White Black Blue White Blue White Yellow Red Black Green Black BALLAST Emergency ballast compatible Green White BALLAST BALLAST Green Black BALLAST Blue Yellow Red Green Black BALLAST BALLAST White Yellow Red BALLAST Black Yellow Red Black Remote Mounting (Max. wire length from Blue Yellow Red Red Yellow Red ballast case to lampholder): B LAMP Blue LAMP Blue LAMP • 20 ft:Blue full wattage T8s Blue LAMP Ye LAMP Blue LAMP LAMP Yellow • 10 ft:Yellow energy saving T8s LAMP R LAMP Red LAMP LAMP LAMP Red • 4 ft: 25W energy saving T8s LAMP LAMP RedLAMP LAMP Red Blue Blue Blue Blue Data based upon SYLVANIA OCTRON® lamps shown. QUICKTRONIC® QHE Instant Start ballasts are also compatible with other lamp manufacturers equivalent lamp types that meet ANSI specifications. Rated Ballast InputSystem Lumens No. of Factor System Mean Power Efficacy (lm) Lamps (BF) Lumens Lumens (W) (lm/W) BEF 1 0.21/0.09 FO32/700 0.21/0.09 FO32/XP® 0.20/0.09 FO30/SS 0.19/0.08 FO28/SS 0.17/0.08 FO25/SS pplication, cap any blue lead. e to 600 volts. ALLAST Input Current Lamp (AMPS) Type Banded Pack 4986110-Pack LAMP AMP Performance Guide High Efficiency Universal Voltage (120-277V), Lamp Striation Control LAMP LAST T8 Instant Start Type Q HE T8 ISL ALLAST Low Ballast Factor SPECIFICATION DATA LAMP Note: For one lamp application, cap any unused blue lead. Insulate to 600 volts. Note: For one lamp application, cap any unused blue lead. Insulate to 600 volts. QUICKTRONIC 2x59* QUICKTRONIC 2x59* QUICKTRONIC 2x96IS Note: For two lamp application, cap any blue lead. Insulate toQUICKTRONIC 600 volts. 2x96IS QUICKTRONIC 3x40DL Blue Blue Red Red LAMP 2x59* QUICKTRONIC LAMP QUICKTRONIC 2x96IS QUICKTRONIC 2x96HO QUICKTRONIC 2x96HO Note: For two lamp application, cap any blue le QUICKTRONIC 3x40 Service and Sales Center 1-800-LIGHTBULB Black (1-800-544-4828) White BALLAST Yellow www.sylvania.com Yellow Blue Blue Red Red Specifications subject to change without notice. LAMP LAMP QUICKTRONIC 2x96HO