HDX Compact DC Power Distribution Center Comm/net Systems, Inc. High current DC circuit breaker distribution center. 300A per bus, 12 circuit breakers, 8 GMT fuse outputs. Excellent solution for both high and low current loads. Single input A/B isolated Input Only 2RU! 11 12 > High density DC distribution for multiple applications. Front access bullet terminal circuit breakers and GMT fuses . > 19"/ 23" Rack mount, 2 R/U high. Includes both AM series plug-in bullet terminal breakers as well as 8 GMT fuse sockets for auxiliary loads . > High power density and ampacity : 300 Amperes per input: (Single input, A/B input). Accepts up to 12 plug-in bullet terminal circuit breakers. > Small RU requirement leaves room for other equipment installation in rack space . > Two-hole lug high current bus bars for input and return terminations. Supports large AWG input cable feeders > Standard unit includes front panel with A and B input LED indicators and breaker/fuse trip indicator LED > Bright, color coded LED indicators for A/B input power status, breaker trip and alarms . . . > Form-C alarm contacts for Major and Minor alarms. Standard version includes breaker/fuse trip alarm relay > Single hole or two hole lug termination bus bar array for circuit breaker protected outputs and returns . . > Flip down front cover panel protects breakers from nuisance tripping. Convenient front access for breaker installation . > Plug-in breakers can be installed incrementally as needed to reduce install cost. Breakers can be changed in seconds to support equipment load and future configuration changes 11 . > Input/output clear plastic termination guard 12 . Advanced Power and Integration Services Doc# 048–009–00/Jan.01.07 HDX Compact DC Distribution Center General Specification: Model # Configuration Part # Description P/N 016-412-10 Single input. 300A Single input,12 breaker sockets, 8 GMT sockets. -48VDC Single input, 300 ampere rated. 12 bullet breaker sockets, 8 GMT sockets. 2 qty form-c alarm contacts. LED front panel indicators. -44 8VDC P/N 016-410-10 A/B isolated input. output, 300A. A/B isolated inputs, split bus output. 6A/6B breaker sockets, 4A,4B GMT sockets. -48VDC Isolated A/B input breaker panel, 300 A per bus. 6A,6B bullet breaker sockets, 4A,4B GMT sockets. 2 qty form-c alarm contacts. LED front panel indicators. -48VDC. Common Specifications for All Models: Dimensions: 17" W x 5.25" H (2 RU) x 12.5" D (incl bus bar protrusion). Weight: 13 Lbs. Rack mount via 19/23" reversible rack mount ears. Two mounting positions: Front flush or mid-mount. Rear clear cover panel for bus bar termination area. Plug-ii n bullet terminal circuit breakers: Select amperage rating and quantity at time of order. CSI P/N: Circuit Breaker Description: 470-235-10 10 AMP AM Breaker, Plug-in Type, Midtrip (5/16" Bullet Terminals) 470-402-10 20 AMP AM Breaker, Plug-in Type, Midtrip (5/16" Bullet Terminals) 470-403-10 30 AMP AM Breaker, Plug-in Type, Midtrip (5/16" Bullet Terminals) 470-407-10 40 AMP AM Breaker, Plug-in Type, Midtrip (5/16" Bullet Terminals) 470-400-10 60 AMP AM Breaker, Plug-in Type, Midtrip (5/16" Bullet Terminals) 470-406-10 80 AMP AM Breaker, Plug-in Type, Midtrip (5/16" Bullet Terminals) 470-404-10 100 AMP AM Breaker, Plug-in Type, Midtrip (5/16" Bullet Terminals) 470-269-10 200 AMP AM Breaker, (2 Pole) Plug-in Type, Midtrip (5/16" Bullet Terminals) Order Info: Shipping costs extra - shipping box packaging for UPS/FedEx shipment. Comm/net Systems, Inc. www.commnetsystems.com Email sales@commnetsystems.com Seattle Corporate Office 4237 24th Avenue W Seattle, WA 98199 Tel. 206 282 8670 Fax. 206 282 8684 Doc# 048–009–00/Jan.01.07 800 274 0544 (24/7 Sales & Service)