HDX
Compact DC Power Distribution Center
Comm/net Systems, Inc.
High current DC circuit breaker distribution center.
300A per bus, 12 circuit breakers, 8 GMT fuse outputs.
Excellent solution for both high and low current loads.
Single input
A/B isolated Input
Only 2RU!
11
12
> High density DC distribution for multiple applications. Front access bullet terminal circuit breakers and GMT fuses
.
> 19"/ 23" Rack mount, 2 R/U high. Includes both AM series plug-in bullet terminal breakers as well as 8 GMT fuse sockets for
auxiliary loads
.
> High power density and ampacity
:
300 Amperes per input: (Single input, A/B input).
Accepts up to 12 plug-in bullet terminal circuit breakers.
> Small RU requirement leaves room for other equipment installation in rack space
.
> Two-hole lug high current bus bars for input and return terminations. Supports large AWG input cable feeders
> Standard unit includes front panel with A and B input LED indicators and breaker/fuse trip indicator LED
> Bright, color coded LED indicators for A/B input power status, breaker trip and alarms
.
.
.
> Form-C alarm contacts for Major and Minor alarms. Standard version includes breaker/fuse trip alarm relay
> Single hole or two hole lug termination bus bar array for circuit breaker protected outputs and returns
.
.
> Flip down front cover panel protects breakers from nuisance tripping. Convenient front access for breaker installation
.
> Plug-in breakers can be installed incrementally as needed to reduce install cost. Breakers can be changed in seconds to
support equipment load and future configuration changes 11 .
> Input/output clear plastic termination guard 12 .
Advanced Power and Integration Services
Doc# 048–009–00/Jan.01.07
HDX Compact DC Distribution Center
General Specification:
Model #
Configuration
Part #
Description
P/N 016-412-10
Single input. 300A
Single input,12 breaker sockets,
8 GMT sockets.
-48VDC
Single input, 300 ampere rated. 12 bullet breaker sockets,
8 GMT sockets. 2 qty form-c alarm contacts. LED front panel
indicators. -44 8VDC
P/N 016-410-10
A/B isolated input. output, 300A.
A/B isolated inputs, split bus output.
6A/6B breaker sockets, 4A,4B GMT
sockets.
-48VDC
Isolated A/B input breaker panel, 300 A per bus. 6A,6B bullet
breaker sockets, 4A,4B GMT sockets. 2 qty form-c alarm contacts. LED front panel indicators. -48VDC.
Common Specifications for All Models:
Dimensions: 17" W x 5.25" H (2 RU) x 12.5" D (incl bus bar protrusion).
Weight: 13 Lbs.
Rack mount via 19/23" reversible rack mount ears.
Two mounting positions: Front flush or mid-mount.
Rear clear cover panel for bus bar termination area.
Plug-ii n bullet terminal circuit breakers: Select amperage rating and
quantity at time of order.
CSI P/N:
Circuit Breaker Description:
470-235-10
10 AMP AM Breaker, Plug-in Type, Midtrip (5/16" Bullet Terminals)
470-402-10
20 AMP AM Breaker, Plug-in Type, Midtrip (5/16" Bullet Terminals)
470-403-10
30 AMP AM Breaker, Plug-in Type, Midtrip (5/16" Bullet Terminals)
470-407-10
40 AMP AM Breaker, Plug-in Type, Midtrip (5/16" Bullet Terminals)
470-400-10
60 AMP AM Breaker, Plug-in Type, Midtrip (5/16" Bullet Terminals)
470-406-10
80 AMP AM Breaker, Plug-in Type, Midtrip (5/16" Bullet Terminals)
470-404-10
100 AMP AM Breaker, Plug-in Type, Midtrip (5/16" Bullet Terminals)
470-269-10
200 AMP AM Breaker, (2 Pole) Plug-in Type, Midtrip (5/16" Bullet Terminals)
Order Info:
Shipping costs extra - shipping box packaging for UPS/FedEx shipment.
Comm/net Systems, Inc.
www.commnetsystems.com Email sales@commnetsystems.com
Seattle Corporate Office
4237 24th Avenue W Seattle, WA 98199 Tel. 206 282 8670 Fax. 206 282 8684
Doc# 048–009–00/Jan.01.07