MODEL NUMBER: XTT900-1-0-GB-XX IMPROX TT ImproX TT Twin Antenna Terminal INTRODUCTION The ImproX TT Terminal is a tag read/write Terminal designed for use within ImproX IXP200, 300 and 400 Access Control Systems or in OEM applications. The ImproX TT is a low cost Terminal designed to provide access control to one door in full anti-pass back mode, or two doors in relaxed anti-passback mode. The Improx TT utilizes two Antenna Readers, two relays and four digital inputs to provide full control of any access application. The ImproX TT is able to interface into IXP200, 300 or 400 systems via an RS485 bus connection. APPLICATIONS The following are possible uses of the ImproX TT: (a) Access control. FEATURES (b) OEM custom applications. ACCESSORIES Various types of Antenna Readers are available for use with the ImproX TT Twin Antenna Terminal. The Terminal is supplied with the following accessories: (a) Wall mounting plugs and screws. The unit provides the following features: (a) Connection to two Antenna Readers. (b) Read-only function using the following tags: Slim tags, Omega tags. (c) Read/Write function using the following tags: WriTag2048, Writag128. (d) Status indicators: • (b) Self-adhesive label for address configuration. • The ImproX TT Terminal provides several diagnostic status indicators for installers. The ImproX TT Antenna Readers each include a single bi-coloured red/green LED, the use of which is configurable from the software (e.g. IXP200 or IXP300/400) via the communications protocol. (e) An external RS485 terminal communications bus interface. (f) Two independent SPDT relay outputs. (g) Four dry contact digital inputs. Page 1 Document Number XTT303-0-0-GB-00 MODEL NUMBER: XTT900-1-0-GB-XX (h) Operation from power inputs in the range 10 V to 30 V DC. (i) Software utility to upgrade firmware while installed on-site, without removal of the unit. (j) The unit supports full Anti-passback (APB). (k) The ImproX MA, MHA, KHA, and KMA Antenna Readers each include a buzzer operating at 4 kHz, each with four volume settings including off. SPECIFICATIONS PHYSICAL SPECIFICATIONS Dimensions L = 132 mm (5.20"). W = 100 mm (3.94"). H = 32 mm (1.26"). Mass 220 g (7.76 oz). Housing Material Base – Yellow passivated mild steel. Lid – biaxially-oriented polypropylene. Color Charcoal grey. ENVIRONMENTAL SPECIFICATIONS Temperature: o o o o Operating -25 C to +60 C (-13 F to +140 F). Storage -40oC to +80oC (-40oF to +176oF). Humidity Range o o 0 to 95% relative humidity at +40 C (+104 F) noncondensing. EMC EN55024. Voltage Dips and Interruptions EN61000-4-11. Electrostatic Discharge EN61000-4-2. Radiated Susceptibility EN61000-4-3. Electrical Fast Transients EN61000-4-4. Surge Immunity EN61000-4-5. Conducted Susceptibility EN61000-4-6. Dust and Splash Resistance The ImproX TT Terminal is designed for indoor use only. Drop Endurance 2 m drop (in packaging). Voltage 10 V to 30 V DC, polarity sensitive. ELECTRICAL SPECIFICATIONS Maximum Power Requirements: Input Voltage = 10 V DC (all features activated) Input Voltage = 30 V DC (all features activated) Current (mA) Power (W) 180 1.8 60 1.8 Power Input Protection Reverse polarity protection, over-current protection and over-voltage protection. Permissible Input Supply Ripple Voltage (maximum) 1 VPP at 50 Hz. Terminal Bus Port: Page 2 Electrical Interface RS485, ASCII with 16-bit CRC checking. Communications Protocol ImproX Secure Communications Protocol. Data Format 8 data bits, no parity, 1 stop bit. Document Number XTT303-0-0-GB-00 MODEL NUMBER: XTT900-1-0-GB-XX Baud Rate 1 200, 2 400, 4 800, 9 600, 19 200, 28 800, 38 400 (default), 57 600 and 76 800 selectable via the protocol. Default Mode Receive mode. Line Termination Provision is made for line termination. Unit Status Slave. Relays (x2): Relay Output (per relay) 1 x SPDT – NO, NC, COM contacts available. Contact Rating 3A at 24 V DC/25 V AC. 1.5 A at 220 V AC. Digital Inputs (x4): Input Type Dry contact. Detection Resistance Range < 5 K OHM. Protection +50 V to –50 V continuous. +80 V to –80 V surge. Processor: Processor Type 16-bit CPU operating at 16 MHz. RAM Memory 2 Kbyte. Flash Memory 64 Kbyte. OPERATOR/INSTALLER INTERFACES ANTENNA READER: Status Indicators: Bi-color Red/Green LED The functioning of this LED is applicationspecific. (Externally visible). Buzzer: Volume Adjustable in four discrete steps (including off) via the application software. Tones Single 4 kHz frequency tone. 12-Button Keypad: TERMINAL : On selected Antenna Readers only. Status Indicators: Incoming RS485 Data Green LED (flashing in accordance with incoming data) (internal to the unit). Outgoing RS485 Data Red LED (flashing in accordance with outgoing data) (internal to the unit). Digital Inputs [1-4] LEDs Continuous Green on detected contact closure. Relays [1&2] LEDs Continuous Red on activation of relay. Status LED Continuous Red indicating power on. Steady flashing Red indicating “Upgrade Mode”. Intermittent flashing Red indicating “RS485 Communications Failure”. FACTORY DEFAULT SETTINGS Page 3 Factory Default Settings: Default Baud Rate Factory-set to 38 400. Default Mode Receive (Slave Mode). Buzzer Volume Level 3 (maximum). Document Number XTT303-0-0-GB-00 MODEL NUMBER: XTT900-1-0-GB-XX TAG READ/WRITE RANGES The range at which the Antenna Readers can read from or write to a tag is dependent on the type of tag, type of Reader and material on which a particular Reader is mounted. Typical ranges are shown in Table 1. TYPICAL RANGE (minimum) (Reader mounted on non-metallic surface) TAG TYPE (mm) (inches) ISO Credit Card (Slim) 60 2.36 ISO Credit Card (Omega) 60 2.36 Tear Drop Tag 40 1.58 Key Ring Tag 40 1.58 Pico Tag 20 0.78 60 2.36 60 2.36 ISO Credit Card Writag2048 ISO Credit Card Writag128 NOTE : Mounting the Reader on a metallic surface will reduce the tag reading range by up to 15%. Table 1 : Typical read/write ranges INTERNATIONAL STANDARDS The ImproX TT unit complies with the requirements of the following international standards where applicable: EIA RS-485 Standard for Electrical Characteristics of Generators and Receivers for use in Balanced Digital Multipoint Systems. EN 55024 Limits and Methods of Measurement of Radio Disturbance Characteristics of Information Technology Equipment. IE6 1000-4-1 Electromagnetic Compatibility (EMC). Part 4: Testing and Section 1: Overview of Immunity Tests. Basic EMC Publication. IE6 1000-4-2 Electromagnetic Compatibility (EMC). Part 4: Testing and Measurement Techniques. Section 2: Electrostatic Discharge Immunity Test. Basic EMC Publication. IE6 1000-4-4 Electromagnetic Compatibility (EMC). Part 4: Testing and Measurement Techniques. Section 4: Electrical Fast Transients / Bursts. Basic EMC Publication. IE6 1000-4-3 Electromagnetic Compatibility (EMC). Part 4: Testing and Measurement Techniques. Section 3: Radiated, Radio Frequency, Electromagnetic Field Immunity Test. IE6 1000-4-6 Conducted Susceptibility. IE6 1000-4-5 Surge Immunity. Page 4 Measurement Techniques. Document Number XTT303-0-0-GB-00 MODEL NUMBER: XTT900-1-0-GB-XX APPROVALS CE Approval: Approved. FCC: Pending. RELATED IMPRO PRODUCTS The ImproX TT Terminal is designed to be used in conjunction with other units in the ImproX range in IXP200, 300 and 400 Systems, and with the ImproX IL Computer in OEM applications. ORDERING INFORMATION Terminal The ImproX TT Terminal can be ordered under the code XTT900-1-0-GB-XX. Antenna Readers The Antenna Readers for use with the ImproX TT Terminal are described in separate catalogue pages. OTHER INFORMATION USE IN DIFFERENT SYSTEMS Use in an IXP200 System When used in an IXP200 system the functions of the relays and inputs are preset. For details, see the ImproX TT Terminal Installation Manual. Use in an IXP300/400 System In IXP300/400 systems the relay and input functions are user configurable. TYPES OF ADDRESSES Each ImproX TT Terminal is, in fact, two Terminals in one. The first “Terminal” Fixed Address is associated with Reader [1], and the second with Reader [2]. Each ImproX TT unit is allocated two unique Fixed Addresses at the factory. These addresses are stored in its memory. When the unit is installed in a system, the system allocates two separate Logical Addresses to the unit for communication purposes. Page 5 Document Number XTT303-0-0-GB-00 MODEL NUMBER: XTT900-1-0-GB-XX Page 6 Document Number XTT303-0-0-GB-00