Instruction Sheet

advertisement
SRK—FLUORESCENT
INSTALLATION INSTRUCTIONS
Warning:
• T
his product must be installed in accordance with the applicable
installation code by a person familiar with the construction and
operation of the product and the hazards involved.
• Make sure all electrical power is turned off while installing the fixture.
• Disconnect power before servicing.
• Always use correct lamp type and wattages.
• T
he retrofit assembly is accepted as a component of a fluorescent
luminaire where the suitability of the combination shall be determined
by authorities having jurisdiction.
• Inspect wiring and components for damage when drilling for installation of retrofit assembly hardware.
• W
ARNING: To prevent wiring damage or abrasion, do not expose
wiring to edges of sheet metal or other sharp objects.
• W
ARNING: Do not make or alter any open holes in an enclosure of
wiring or electrical components during kit installation.
5.Attach the ground wire to the fixture with self-tapping screws and
make electrical connections.
Supply
• T
his luminaire must be adequately grounded for protection against
shock hazards and to assure proper operation.
• W
ARNING: Risk of fire or electric shock. Retrofit kit installation
requires knowledge of fluorescent lighting luminaires electrical
systems. If not qualified, do not attempt installation. Contact a
qualified electrician.
• O
nly those open holes indicated in the photographs and/or drawings
may be made or altered as a result of kit installation. Do not leave any
other open holes in an enclosure of wiring or electrical components.
Ground
6.Pull tension on the chain while lifting wireway cover into place.
Make certain the wireway is free from obstructions and slide the
chain into the smaller portion of the slot.
Black
Black
White
White
Ballast/Driver
Ballast/Driver
Disconnect
Ground wire if needed
Tools Required:
(2) Chains
• W
ARNING: Risk of fire or electric shock. Install this kit only in
luminaires that have the construction features and dimensions shown
in the photographs and/or drawings.
(2) “L” Brackets
(4) 8” UNC Self Tapping Screws
• W
ARNING: Risk of fire or electric shock. Luminaire(s) wiring, ballasts,
or other electrical parts may be damaged when drilling for installation
of reflector kit hardware. Check for enclosed wiring and components.
(2) Chain Boxes
7.Collect the excess chain inside chain box and snap into position on
the wireway cover.
8.Use the screw head to slide the row aligner into the end of the
adjacent fixture and tighten the screw to secure.
(2) Wire Nuts
T he SRK series (Strip Retrofit Kit) is designed to fit any existing fluorescent strip housing (4” – 4-1/2” width) with end plates, made by any
manufacturer; however, H.E. Williams, Inc. suggests installing the kit on one of the existing fixtures to check compatibility before beginning a
complete retrofit. Remove the wireway cover, sockets, and ballast(s) from the existing fixture so that only the empty channel and end plates
remain. Install as follows:
1. Install lamp socket at each end of the SRK wireway cover.
2.Feed the small end of the ball chain through the keyhole slots in
the wireway.
3.Attach “L” brackets into existing channel with self-tapping screws.
Position according to fixture length.
OPTIONAL END CAP ACCESSORY INSTALLATION INSTRUCTIONS
1.Separate upper and lower halves of the end plate
by bending repeatedly.
2.Attach the lower portion of the end plate to the wireway cover
with two #8 sheet metal screws (included).
3.If overall height of fixture is 2” or less, discard top half of end
plate. If height is greater than 2”, remove existing channel end and
install the end plate with self-tapping screws.
4.Fixture A is shown with only the bottom half of end plate.
Fixture B is taller and uses both halves of end plate.
4.Raise the wireway and feed two links of ball chain into the keyhole
slot on the “L” bracket.
A
B
H.E. Williams, Inc.
1/05/16JL
Carthage, Missouri
w w w.hew.com
417-358-4065
Page 2
PN #49090001
Download