BXUV.W430 - Fire-resistance Ratings - ANSI/UL 263

advertisement
BXUV.W430 - Fire-resistance Ratings - ANSI/UL 263
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAM...
Design No. W430
BXUV.W430
Fire-resistance Ratings - ANSI/UL 263
Page Bottom
Design/System/Construction/Assembly Usage Disclaimer
Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL
Certified products, equipment, system, devices, and materials.
Authorities Having Jurisdiction should be consulted before construction.
Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with
applicable requirements. The published information cannot always address every construction nuance encountered in the field.
When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product
manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each
product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate
methods of construction.
Only products which bear UL's Mark are considered Certified.
BXUV - Fire Resistance Ratings - ANSI/UL 263
BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada
See General Information for Fire-resistance Ratings - ANSI/UL 263
See General Information for Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada
Design No. W430
July 01, 2014
Nonbearing Wall Rating — 45 Min.
* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such
as Canada), respectively.
1. Floor and Ceiling Runners — (Not shown) — Channel shaped, fabricated from min 25 MSG corrosion-protected
steel, min depth to accommodate stud size, with min 1-1/4 in. long legs, attached to floor and ceiling with fasteners
spaced 24 in. OC max.
2. Steel Studs — Channel shaped, fabricated from min 25 MSG corrosion-protected steel, min depth 3-5/8 in., spaced a
max of 24 in. OC. Stud length to be same as assembly height. Studs attached to floor and ceiling runners with min 1/2
in. long, No. 8 flat head screws.
3. Batts and Blankets — Placed in stud cavities, any min 3 in. thick, min 4.5 pcf density, min 98% inorganic, mineral
wool insulation batts tightly fit in between studs and floor and ceiling runners. Insulation butt joints staggered from all
horizontal joints of Cementitious Backer Units, Item 4.
4. Cementitious Backer Units* — Minimum nominal 6 mm thick Type Superboard Estándar and minimum nominal 8
mm thick Type Superboard Juntas, applied vertically or horizontally with vertical joints centered over studs. Inner layer
1 of 2
3/02/15 14:50
BXUV.W430 - Fire-resistance Ratings - ANSI/UL 263
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAM...
(minimum 6 mm Type Superboard Estándar) attached to studs and tracks with 1 in. long, Type S screws spaced 12 in.
OC in the field and perimeter, starting 1 in. and 6 in. from the edges. At the floor and ceiling runners, screws start 2 in.
and 6 in. from the top and bottom of the assembly to avoid the floor and ceiling runner flanges. Along the floor and
ceiling runners, screws start 4 in. from the side edge of the panel. Outer layer (minimum 8 mm Type Superboard Juntas)
attached to studs and tracks with 1-1/4 in. long, Type S screws spaced 12 in. OC, starting 1 in. and 12 in. from the
edges. At the floor and ceiling runners, screws start 3 in. and 12 in. from the top and bottom of the assembly to avoid
the floor and ceiling runner flanges. Along the floor and ceiling runners, screws start 5 in. from the side edge of the
panel. All face layer joints staggered min 24 in. from underlying base layer joints. Joints staggered on opposite sides of
the studs. All screw holes in the panels are pre-drilled with a 5/16 in. drill bit, to countersink the screw heads flush with
the surface of the inner layer and outer layer panels. Joints and screw heads need not be covered with joint compound.
SKINCO COLOMBIT S A — Type Superboard Estándar (inner layer), Type Superboard Juntas (outer layer).
* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification
(such as Canada), respectively.
Last Updated on 2014-07-01
Questions?
Print this page
Terms of Use
Page Top
© 2015 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a
non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory
with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in
the following format: "© 2015 UL LLC".
2 of 2
3/02/15 14:50
Download