Installation - Maintenance
General Information
1. Safety information
2. Scope of Operation
3. General product information
4. Order codes
Installation instructions
5. Step by step mounting instructions
6. Connections and wiring
7. Light Distribution
Operating Instructions
8. Mains Operation
9. Emergency Operation
10. Autotest Operation
11. Dimensions
.......................................................................... 4
.......................................................................... 5
.......................................................................... 5
.......................................................................... 5
.......................................................................... 5
.......................................................................... 6
.......................................................................... 6
.......................................................................... 6
.......................................................................... 7
.......................................................................... 7
.......................................................................... 7
.......................................................................... 7
Ÿ
Ÿ
Ÿ
SAFETY INSTRUCTIONS
The device shall only be used for its intended purpose and in undamaged and awless condition
Only genuine Eaton spare parts may be used for replacement and repair
Observe the national safety rules and regulations to prevent accidents as well as the safety instructions included in these instruction lea et
Sirios-LED Emergency Lighting www.eaton.com
3
A
230VAC
B
230VAC
SLO
C
HR
VC
DK
4
EE
D
LT
Y:
Y:
G:
G:
Sirios-LED Emergency Lighting www.eaton.com
OK
TEST
1. Safety Information 3. General Product Information
Observe the national safety rules and regulations to prevent accidents as well as the safety instructions included in these instruction lea et.
Light Source:
24 white LED 1.5W
Materials:
White polycarbonate base and re ector
Clear polycarbonate diffuser
Installation:
Wall and Ceiling
Installation kit for recessed wall and ceiling
Base for quick mounting
(accessory)
Panel, double-sided printed for reporting security (optional)
Protection Kit IP65 for outdoor use
Operation:
Maintained & Non-
Maintained (user selectable)
Autonomy 1h up to 3h
Functional test integrated into the diffuser
Inhibition and Rest Mode
Autotest & slave models available
Applications:
Schools, universities, public administration, commercial environments
12h
0% 1h
12h
100%
24h charge for optimal operation recyclable parts complying with WEEE directive
IP42 designed for indoor use
(for outdoor applications use IP65 kit) temperature range
0
2. Scope of Operation
Sirios LED is range of emergency lights with low pro le, designed and equipped with technical solutions and accessories for a wide range of applications such as of ces, restaurants, hotels, hospitals and general commercial applications class II
The range of accessories includes a recessed base for installation to walls and false ceilings and an IP65 weatherproof kit.
4. Order codes
Sirios LED order codes
Order code
O-SLED
O-SLED-3H
O-SLED-AT
O-SLED-AT-3H
O-SLED-MAINS
Description
Sirios LED 2hours self-contained
Sirios LED 3hours self-contained
Sirios LED 1hour Autotest
Sirios LED 3hours Autotest
Sirios LED Mains
Sirios LED emergency lights are suitable for both antipanic and up to 30m viewing distance exit sign applications.
Sirios LED front view
Accessories
Order code
O-SLED-STRIPE
O-S-WB
O-S-RB
O-S-IP
171-000-032
171-000-035
Description
Led stripe accessory for Sirios LED
Wall mounting base
Recessed base
Weatherproof base
Vertical metal base (O-MP41)
Horizontal metal base (O-PU41)
Sirios-LED Emergency Lighting www.eaton.com
5
5. Step by step Mounting Instructions 7. Light Distribution
1 2
By changing the orientation of the LED strip you can adjust and choose the light distribution of Sirios LED
12
3 4
5
6. Connections & wiring
6 7
8 clic k
10
11 clic k
230VAC !
Open position
( Λ ) suggested application for Escape
Route, up to 9,5m in
4m height
Closed position
(II) suggested application for Antipanic
Summary
Application
Led position
Exit Sign Antipanic Escape Route
Open ( Λ ) Best* Best** Good
Closed ( ΙΙ ) Good Good Best***
* Better uniformity on sign
** Bigger covering area,
*** Longer distance in smaller heights, lower illuminance
diversity along the route path
13 click click
6 Sirios-LED Emergency Lighting www.eaton.com
8. Mains Operation
Autotest indications Maintained operation
L
N
L1
Maintain:
S1
S1
L
N
L1
S1 L1
Y:
Functional test, every week (7x24h)
Duration test, every 10 weeks (70x24h)
Y:
Manual test
G:
G:
ECO operation
C6 ONLY @ MAINS
MAX
S2
{
ECO
S2
Max = 50mA (100%)
Eco = 33mA (66%)
9. Emergency Operation
Telecommand wiring
SB
SA
11. Dimensions
Sirios LED
EX500
1-2,5
B+ A-
359mm
121mm
OK
TEST
Inhibition wiring
SWITCH
1-2,5
SB
SA
336mm
Sirios recessed base
171mm
10. Autotest Operation
Telecommand operation
384mm
361mm
Sirios weatherproof base
TLU500
B+ A-
1-2,5
153mm
357mm
358mm
Sirios-LED Emergency Lighting www.eaton.com
7
Eaton Industries Manufacturing
Electrical Sector EMEA
Route de la Longeraie 7
1110 Morges, Switzerland
Eaton.eu
Cooper Univel S.A.
Thessalonikis 88
60100 Katerini, Greece
© 2014 Eaton
All Rights Reserved
Printed in EU
Publication No. 1-05-250 (R2)
August 2014
Eaton is a registered trademark.
All other trademarks are property of their respective owners.