Installation and Operation Manual Sirios LED

Installation and Operation Manual

Sirios LED Emergency Lighting

Table of Contents

Installation - Maintenance

General Information

1. Safety information

2. Scope of Operation

3. General product information

4. Order codes

Installation instructions

5. Step by step mounting instructions

6. Connections and wiring

7. Light Distribution

Operating Instructions

8. Mains Operation

9. Emergency Operation

10. Autotest Operation

11. Dimensions

.......................................................................... 4

.......................................................................... 5

.......................................................................... 5

.......................................................................... 5

.......................................................................... 5

.......................................................................... 6

.......................................................................... 6

.......................................................................... 6

.......................................................................... 7

.......................................................................... 7

.......................................................................... 7

.......................................................................... 7

Ÿ

Ÿ

Ÿ

SAFETY INSTRUCTIONS

The device shall only be used for its intended purpose and in undamaged and awless condition

Only genuine Eaton spare parts may be used for replacement and repair

Observe the national safety rules and regulations to prevent accidents as well as the safety instructions included in these instruction lea et

Sirios-LED Emergency Lighting www.eaton.com

3

Sirios LED Emergency Lighting - Installation / Maintenance

A

230VAC

B

230VAC

SLO

C

HR

VC

DK

4

EE

D

LT

Y:

Y:

G:

G:

Sirios-LED Emergency Lighting www.eaton.com

OK

TEST

Sirios LED Emergency Lighting - General Information

1. Safety Information 3. General Product Information

Observe the national safety rules and regulations to prevent accidents as well as the safety instructions included in these instruction lea et.

Light Source:

24 white LED 1.5W

Materials:

White polycarbonate base and re ector

Clear polycarbonate diffuser

Installation:

Wall and Ceiling

Installation kit for recessed wall and ceiling

Base for quick mounting

(accessory)

Panel, double-sided printed for reporting security (optional)

Protection Kit IP65 for outdoor use

Operation:

Maintained & Non-

Maintained (user selectable)

Autonomy 1h up to 3h

Functional test integrated into the diffuser

Inhibition and Rest Mode

Autotest & slave models available

Applications:

Schools, universities, public administration, commercial environments

12h

0% 1h

12h

100%

24h charge for optimal operation recyclable parts complying with WEEE directive

IP42 designed for indoor use

(for outdoor applications use IP65 kit) temperature range

0

2. Scope of Operation

Sirios LED is range of emergency lights with low pro le, designed and equipped with technical solutions and accessories for a wide range of applications such as of ces, restaurants, hotels, hospitals and general commercial applications class II

The range of accessories includes a recessed base for installation to walls and false ceilings and an IP65 weatherproof kit.

4. Order codes

Sirios LED order codes

Order code

O-SLED

O-SLED-3H

O-SLED-AT

O-SLED-AT-3H

O-SLED-MAINS

Description

Sirios LED 2hours self-contained

Sirios LED 3hours self-contained

Sirios LED 1hour Autotest

Sirios LED 3hours Autotest

Sirios LED Mains

Sirios LED emergency lights are suitable for both antipanic and up to 30m viewing distance exit sign applications.

Sirios LED front view

Accessories

Order code

O-SLED-STRIPE

O-S-WB

O-S-RB

O-S-IP

171-000-032

171-000-035

Description

Led stripe accessory for Sirios LED

Wall mounting base

Recessed base

Weatherproof base

Vertical metal base (O-MP41)

Horizontal metal base (O-PU41)

Sirios-LED Emergency Lighting www.eaton.com

5

Sirios LED Emergency Lighting - Installation instructions

5. Step by step Mounting Instructions 7. Light Distribution

1 2

By changing the orientation of the LED strip you can adjust and choose the light distribution of Sirios LED

12

3 4

5

6. Connections & wiring

6 7

8 clic k

10

11 clic k

230VAC !

Open position

( Λ ) suggested application for Escape

Route, up to 9,5m in

4m height

Closed position

(II) suggested application for Antipanic

Summary

Application

Led position

Exit Sign Antipanic Escape Route

Open ( Λ ) Best* Best** Good

Closed ( ΙΙ ) Good Good Best***

* Better uniformity on sign

** Bigger covering area,

*** Longer distance in smaller heights, lower illuminance

diversity along the route path

13 click click

6 Sirios-LED Emergency Lighting www.eaton.com

Sirios LED Emergency Lighting - Operating instructions

8. Mains Operation

Autotest indications Maintained operation

L

N

L1

Maintain:

S1

S1

L

N

L1

S1 L1

Y:

Functional test, every week (7x24h)

Duration test, every 10 weeks (70x24h)

Y:

Manual test

G:

G:

ECO operation

C6 ONLY @ MAINS

MAX

S2

{

ECO

S2

Max = 50mA (100%)

Eco = 33mA (66%)

9. Emergency Operation

Telecommand wiring

SB

SA

11. Dimensions

Sirios LED

EX500

1-2,5

B+ A-

359mm

121mm

OK

TEST

Inhibition wiring

SWITCH

1-2,5

SB

SA

336mm

Sirios recessed base

171mm

10. Autotest Operation

Telecommand operation

384mm

361mm

Sirios weatherproof base

TLU500

B+ A-

1-2,5

153mm

357mm

358mm

Sirios-LED Emergency Lighting www.eaton.com

7

Eaton Industries Manufacturing

Electrical Sector EMEA

Route de la Longeraie 7

1110 Morges, Switzerland

Eaton.eu

Cooper Univel S.A.

Thessalonikis 88

60100 Katerini, Greece

© 2014 Eaton

All Rights Reserved

Printed in EU

Publication No. 1-05-250 (R2)

August 2014

Eaton is a registered trademark.

All other trademarks are property of their respective owners.