Oil Distribution Transformers Minera Up to 2500 kVA, insulation ≤ 24 kV, losses PM102308 • • • • • • • 4 bi-directional flat rollers 2 lifting and untanking lugs 2 pulling eyes on the frame 2 earthing terminals on the cover (M12 studs) 1 filling plug 1 draining device according to EN 50216-4 or DIN 42551 1 aluminium rating plate Options • Protection relays (DMCR® or DGPT2®) on the filling plug • • 1 free, thermometer pocket Control device in the thermometer pocket (pointer thermometer with 0 or 2 contacts max, 2-contact thermostat, etc.) 3 HV porcelain bushings (250 A) 4 LV porcelain bushings (from 250 kVA) LV, cable box IP21 or IP54 (only with plug-in bushings on the HV side) Locking device for plug-in bushings (with or without lock) 3 mobile connectors for plug-in bushings – straight or elbow (cable characteristics must be specified) Liquid retention bund Minera - Oil immersed Transformer • • • Standard These transformers comply with standards: • EN 50464-1 • EN 60076-1 to 10 Schneider Electric guarantees that its transformers are assembled using new, PCB-free components. • • Description Dielectric liquid • • • First refining mineral oil Tested in accordance with IEC 60296 Compatible with all the transformer’s components Standard fitting • • • • One 3 or 5 positions off-circuit tap changer on the cover, with padlocking facility 3 HV plug-in bushings (250 A / 24 kV) on the cover 4 LV flat-bars (from 250 kVA) 4 LV porcelain bushings (from 50 to 160 kVA) • The above options concern usual cases and are not restrictive. For other information,please consult us. Load losses performance According to EN 50464-1 Optimum efficiency 0 SM100117 No-load losses performance SM100100 Mineral oil-immersed, 50 Hz, three-phase distribution transformers with the following characteristics: • Hermetically sealed with integral filling • Cover bolted to the tank • ONAN-type natural cooling • Indoor / outdoor use (depending on selected fittings and options) • Anti-corrosion surface treatment : corrositivity category class C3, “Medium” durability (according to ISO 12944-2) • Final colour RAL 7033 • Protection index IP00 (coverless version) According to EN 50464-1 Optimum efficiency Ak A0 B0 C0 C0 D0 E0 Standard efficiency 0 Bk Ck Dk Standard efficiency Ck C0 Ck Oil Distribution Transformers Minera C0 Ck Electrical characteristics Power (kVA) 100 Primary voltage 15 and/or 20kV 160 250 315 400 500 630 630 800 1000 1250 1600 2000 2500 Secondary voltage 400 to 433V between phases, 231 to 250V phase to neutral (at no load) HV insulation level 17.5kV for 15kV - 24kV for 20kV HV tapping range ± 2.5 % and/or ± 5 % Vector group Yzn 5 / Yzn 11 (50kVA version only) - Dyn 5 / Dyn 11 No-load losses (w) 210 300 425 520 610 720 Load losses (w) 1750 2350 3250 3900 4600 5500 860 800 930 1100 1350 1700 2100 2500 6500 6750 8400 10500 13500 17000 21000 26500 Impedance voltage (%) 4 4 4 4 4 4 4 6 6 6 6 6 6 6 - power LWA 49 52 55 57 - pressure LPA (1m) 41 43 45 47 58 59 60 60 61 63 64 66 68 71 48 49 50 50 50 52 53 55 56 59 Acoustic Level dB(A): Dimensions and weights HV side F F SM100026 SM100027 earthing terminal D C J B K 125 Bushings are marked according to the IEC 60616 standard. D: Height over LV cable box (optional accessory, compatible with HV plug-in bushings only). 1W 1V 1U 2W 2V 2U 2N free thermometer pocket Dimensions and weights are for guidance only, and are provided for a single-voltage transformer with the following electrical characteristics: 20 kV (HV) / 400 V (LV) – 5-position tap changer, ± 2 x 2.5 %. filling plug rating plate 40 Note: tap changer earthing terminal lifting lug H H H A 38 corrugated panels in the corners according to cooling needs LV side Rated power (kVA) 100 160 250 315 400 500 630 630 800 1000 1250 1600 2000 2500 Dimensions -A 1000 1000 1050 1250 1300 1400 1450 1550 1550 1750 1800 1850 2000 2250 (mm) -B 600 750 800 850 850 900 950 950 1000 1100 1150 1200 1350 1300 -C 880 1030 1040 1140 1140 1240 1240 1240 1300 1350 1350 1400 1450 1680 -D 1160 1310 1380 1480 1480 1580 1580 1580 1640 1690 1755 1805 1950 2180 -F 265 265 265 265 265 265 265 265 265 265 265 265 265 265 -H 80 75 150 150 150 150 150 150 150 150 170 170 170 170 -J 520 520 520 670 670 670 670 670 670 670 820 820 820 820 -K 105 105 105 105 105 105 105 105 105 85 85 85 85 85 -Oil 125 160 200 230 260 300 350 390 420 480 580 670 800 1050 -Total 580 750 950 1100 1300 1500 1800 1780 2100 2400 2750 3250 4000 5200 Weight (kg) Terminations Rated current (A) LV flat-bars On request 1250 1250 1250 1250 1250 1250 1250 1600 2500 2500 3150 5000 LV porcelain bushings 250 630 630 630 1000 1000 1000 2000 2000 2000 3150 3150 4500 LV Terminations Ø 18 Ø 18 3150 A 2500 A LV bus-bars terminations - EN 50387 (standard from 250 kVA) 5000 A 70 20 165 250A M 20 60 178 630A 26 Ø 14 263 1000A 17 26 M 30 100 100 25 20 40 15 120 Ø 14 340 M 42 2000A 60 120 Ø 14 3150A 290 255 locking device 150 87 locking device HV plug-in bushings 250 A/24 kV (standard). 40 40 30 M 12 70 20 40 372 150 Ø18 40 450 M 55 SM100031 SM100029 10 M 12 60 50 15 SM100030 310 50 250 250 50 135 50 50 200 45 52 Ø 14,5 Ø 11 1600 A 1250 A 12 50 HV Terminations - EN 50180 20 25 45 Ø 14,5 Ø 11 31,5 120 12 35 106,5 31,5 31,5 120 50 52 Ø 14,5 Ø 11 31,5 97,5 12 31,5 12 221 31,5 31,5 31,5 52 63 31,5 31,5 155 SM100028 63 31,5 100 M 48 4500A LV porcelain bushings - EN 50386 (in standard from 50 to 160 kVA – in option for other powers) © Schneider Electric. All rights reserved. 250 385 250 A HV porcelain bushing 250 A (option) Schneider Electric Industries SAS 35, rue Joseph Monier CS 30323 F - 92506 Rueil Malmaison Cedex (France) Tél. : +33 (0)1 41 29 70 00 RCS Nanterre 954 503 439 Capital social 896 313 776 € www.schneider-electric.com NRJED312371EN As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. Design: Schneider Electric Industries SAS Photos: Schneider Electric Industries SAS 05-2012