INSTALLATION INSTRUCTIONS E-PG PARKING/GARAGE LIGHT FIXTURE CI308X50R2 Document: Date 2015-8-24 Created By: TMT2015-226 DCR# PENDANT MOUNTING 1. Using a 1/2" NPT threaded pipe (supplied by others) feed the wire coming out of the fixture through the conduit pipe as shown in Figure 2. 2. Screw pipe into threaded fitting on top of fixture. 3. Connect opposite end of the pipe to mounting surface and wire as shown in Electrical Connection section. 13.00 JUNCTION BOX MOUNTING 11.20 1. Remove the cover from the fixture by removing (4) screws around the perimeter. 2. Remove lower assembly from the cover by disconnecting two quick connect splice connectors and set lower assembly aside for reinstallation later. 3. Make wire connections between leads coming from the top of the cover to supply leads in junction box as shown in Electrical Connection section. 4. Once electrical connections have been made attach cover to junction box using slots on the cover. See Figure 3. 5. Reattach lower assembly to cover by reconnecting two quick connect splice connectors that were disconnected in Step 2 above. 6. Push lower assembly up into cover ensuring that no leads are pinched, and align holes on cover with corresponding holes on the lower assembly. 7. Replace (4) screws removed in Step 1. 5.43 CAUTIONS IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. 2. 3. 4. 5. DANGER- Risk of shock- Disconnect power before installation. DANGER – Risque de choc – Couper l’alimentation avant l’installation. This luminaire must be installed in accordance with the NEC or your local electrical code. If you are not familiar with these codes and requirements, consult a qualified electrician. Ce produit doit être installé conformément à NEC ou votre code électrique local. Si vous n’êtes pas familier avec ces codes et ces exigences, veuillez contacter un électricien qualifié. This light is suitable for damp, wet locations Convient aux emplacements humides ou emplacements mouillés. WARNING : Risk of fire. ATTENTION - Risque d’incendie. Do not allow the fixture to hang from the harness. This may cause damage to the circuit. FIGURE 2 Apply teflon tape to pipe before installation 1/2 NPT Threaded Pipe SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE INSTALLATION INSTRUCTIONS 1. Unpack fixture from both boxes. Fixture consists of two power supplies mounted on the inside of the top hat lid of the fixture. The lower assembly has the light engine and harness. 2. The LED Garage Light fixture can be pendant mounted to a 1/2"NPT threaded fitting or flush mounted directly to a 4" square or 4" octagonal J-Box. FIGURE 3 Slots FIGURE 1 www.e-conolight.com | 888.243.9445 | FAX: 262.504.5409 INSTALLATION INSTRUCTIONS E-PG PARKING/GARAGE LIGHT FIXTURE CI308X50R2 Document: Date 2015-8-24 Created By: TMT2015-226 DCR# ELECTRICAL CONNECTION FCC NOTICE Fixture is equipped with universal volt driver 120-277V CAUTION: Changes or modifications not expressly approved could void your authority to use this equipment. (ie. 120V, 208V, 240V or 277V) PHASE TO NEUTRAL WIRING 120/277V 1. Connect supply ground to fixture ground (green) lead. 2. Connect supply common to fixture neutral (white) lead. 3. Connect supply Vin to fixture hot (black) lead. PHASE TO PHASE WIRING 208/240V 1. Connect supply ground to fixture ground (green) lead. 2. Connect supply L1 (Hot) to fixture neutral (white) lead. 3. Connect supply L2 (Hot) to fixture hot (black) lead. NOTE: The fixture can be dimmed with a 0-10V dimming control using violet and grey leads on driver. Refer to instructions supplied with dimmer. LED NEUTRAL DRIVER GND – OUT + DIM – DIM WHI NEUTRAL GRN GND CONNECT TO 0-10V DIMMING CONTROL LED LIGHT ENGINE + OUT LINE GRN WHI BLK CONNECT TO AC POWER LINE SP NEUTRAL GND – OUT LED DRIVER + DIM – DIM This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the device is operated in a commercial environment. This device generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this device in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. INDUSTRY CANADA STATEMENT This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. In addition, this device complies with ICES-003 of the Industry Canada (IC) Regulations. + OUT BLK LINE This device complies with Part 15 of the FCC Rules. Operation to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CONNECT TO 0-10V DIMMING CONTROL Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. black - line white - neutral green - ground Warning! Do not allow the fixture to hang from the harness. This may cause damage to the circuit. www.e-conolight.com | 888.243.9445 | FAX: 262.504.5409