AC05 Intronics Power Inc. 1400 Providence Highway, Building 2, Norwood, MA 02062-5015 ● Phone: 1-781-551-5500 ● Fax: 1-781-551-5555 FILE NAME: AC350 Series.doc, REVISION: July 12, 2007 V10 AC350 SERIES 350 WATT SINGLE OUTPUT U FRAME AC-DC POWER SUPPLY WITH PFC FEATURE * Universal lnput 90-264Vac * Active PFC Meets EN61000-3-2 * EMI Meets CISPR/FCC Class B * High Efficiency at 90% * Remote Voltage Sense MODEL VOLTAGE OUTPUT CURRENT(A) RIPPLE VOLTAGE LINE VOLTAGE EFFICIENCY REG.4 (TYPICAL) OUTPUT RATED MIN. & NOISE 1 AC350S-120 +12V 29.2 0 100mVp-p ±2% ±0.5% 10.8~13.2 ±1% 88% AC350S-150 +15V 23.4 0 100mVp-p ±2% ±0.5% 13.5~16.5 ±1% 88% AC350S-240 +24V 14.6 0 150mVp-p ±2% ±0.5% 21.6~26.4 ±1% 90% AC350S-360 +36V 9.7 0 150mVp-p ±2% ±0.5% 32.4~39.6 ±1% 90% AC350S-480 +48V 7.3 0 150mVp-p ±2% ±0.5% 43.2~52.8 ±1% 91% 1 REG.3 ADJ.RANGE LOAD ACCURAC Y2 FILE NAME: AC350 Series.doc, REVISION: July 12, 2007 V10 SPECIFICATIONS Typical at 25℃, nominal line and 75% load, unless otherwise Specified AC350S Series Derating Curve INPUT SPECIFICATIONS: Frequency ………………………………………….……………..... 47 to 63Hz lnrush Current ………………….……………....................................... 85A max. EMI …………………………..…………………………..……CISPR/FCC Class B lsolation ……………………………………………...…lnput to output =3000VDC Leakage Current………………………………………………….……… 2mA max OUTPUT SPECIFICATIONS: Total Rated Output Power……………………………………………………350W (with 20CFM air flow or optional fan) Remote Voltage Sense………………………..…Compensates for wire Voltage Hold-up Time ………………………………………………………..……16mS typ. Over Voltage Protection………………………..…….Recycle AC input to restart Over Temperature Protection……………….………………….….Auto Recovery Short Circuit Protection…………………………………..………. .Auto Recovery Load(%) AC lnput Voltage …....………........…........................................... 90~264Vac 100 90 80 70 60 50 40 30 20 10 0 -10 ENVIRONMENTAL CHARACTERISTICS: or the operating temperature Storage Temperature ………………………………...….......……........ -40~85℃ 10 20 30 40 50 Ambient Temperature(Deg.C) CN1 (AC lnput) Pin Name NOTE 1 2,4 3 5 FG N/A N L GOUND MECHANICAL CHARACTERISTICS: CN2 (AC lnput) Dimensions…………………………………………………...…235.2x101.5x38mm NOTE: Pin 1~9 Name +48 NOTE 1: Add a 0.1uF ceramic capacitor and a 47uF E.L. capacitor to output for Ripple & Noise measuring @20MHz BW. CN3 (AC lnput) 2: Voltage accuracy is set at 60% rated load and 25℃.Ta. Pin 10~18 3: Line regulation is measured from High Line to Low Line with rated load. 5: Load regulation is measured at 60%±40% rated load. 6: Dimensions tolerance : +/- 1mm. 7: CN1(AC lnput) : Molex 5273-05A or equivalent CN2(DC Output) : Molex 5273-09A or equivalent CN3(DC Output) : Molex 5273-09A or equivalent Mechanical Specification Typical at 25˚C, nominal line and 75% load, unless otherwise Specified 2 60 PIN CONNECTION Operating Temperature ......................................................................-10~65℃ 45~65℃ with 2%/℃ Derating PSU will be in thermal protection for exceeding the rated power output 0 Name GND NOTE 70 AC200X SERIES AC200X12 AC200X24 AC200X36 AC200X48 1400 PROVIDENCE HIGHWAY • BUILDING 2 NORWOOD, MASSACHUSETTS 02062-5015 PHONE: 781-551-5500 FAX: 781-551-5555 AC200X Series Derating Curve AC 200 Series New Product 200 Watt Single Output U Frame AC-DC Modules with PFC BAUART .. GEPRUFT .. TYPE APPROVED FEATURES SPECIFICATIONS 1.5” Low Profile, 4”X6” Footprint Universal Input : 90 ~ 264Vac Active PFC Meets EN61000-3-2 EMI Meets CISPR/FCC Class B High Efficiency at 80% Typical Current Share Remote Voltage Sense AC OK Signal (Logic High) DC OK Signal (Logic High) PS ON/OFF Remote Control (Inhibit PSU by adding Logic High) NOTE 1: Optional function can be added when ordering: Top Cover with Fan (when forced air is needed) 2: Add a 0.1uF ceramic capacitor and a 47uF E.L. capacitor to output for Ripple & Noise measuring @20MHz BW. 3: Voltage accuracy is set at 60% rated load and 25℃ Ta. 4: Line regulation is measured from High Line to Low Line with rated load. 5: Load regulation is measured at 60%±40% rated load. 6: Dimensions tolerance : +/- 1mm. 7: Connectors: CN1(AC Input) : Molex 5273-05A or equivalent CN2(DC Output) : Molex 38700-7504 or equivalent CN6(Signals) : Molex 70247-10 or equivalent CN3,CN4,CN5(FAN) : Molex 5045-02A or equivalent Input Characteristics AC Input Voltage Frequency Inrush Current EMI Isolation Leakage Current Output Characteristics Total Rated Output Power Current Share Remote Voltage Sense Hold-up Time Over Voltage Protection Over Temperature Protection Short Circuit Protection Environmental Characteristics Operating Temperature Output Storage Temperature Mechanical Outline 90 ~ 264Vac 47 to 63Hz 60A Max. CISPR/FCC Class B Input to output = 4,242Vdc 3.5mA max. 200W (with 30CFM air flow or optional fan) Single wire current sharing Compensates for wire voltage drop 16mS typ. Recycle AC input to restart Auto Recovery Auto Recovery 0 ~ 70 degrees C 50~70 C with 2.5%/ degrees C derating PSU will be in thermal protection for exceeding the rated power output or the operating temperature -20 ~ 85 C Standard U Frame 150mmx100mmx38.1mm ( 5.91”*3.94”*1.5”) With Optional Fan 150mmx101.6mmx58.5mm ( 5.91”*4”*2.3”) Output Current (A) Ripple Voltage Line Load Model Voltage Rated Min. & Noise Accuracy Reg. Reg. AC200-033 +3.3V 40.0 0 1% ±1% ±1% ±1% AC200-050 +5.0V 40.0 0 1% ±1% ±1% ±1% AC200-120 +12V 16.7 0 1% ±1% ±1% ±1% AC200-150 +15V 13.4 0 1% ±1% ±1% ±1% AC200-180 +18V 11.2 0 1% ±1% ±1% ±1% AC200-240 +24V 8.4 0 1% ±1% ±1% ±1% AC200-280 +28V 7.2 0 1% ±1% ±1% ±1% AC200-300 +30V 6.7 0 1% ±1% ±1% ±1% AC200-360 +36V 5.6 0 1% ±1% ±1% ±1% AC200-480 +48V 4.2 0 1% ±1% ±1% ±1% Typical @25℃, 230Vac and 60% rated load, unless otherwise specified. AC 200 Series New Product 200 Watt Single Output U Frame AC-DC Modules with PFC DRAWINGS: (Preliminary) CN1 Fig.1. Mechanical Outline of AC200 Unit: inch (mm) Fig.2. Mechanical Outline of AC200-F (With Optiona1 Fan) Unit: inch (mm) PIN CONNECTION: CN6(Signals) CN1 (AC Input) PIN NO. ASSIGNMENT 1 Earth Ground 2 PIN10: NC PIN9: NC PIN8: NC PIN7: +V CSW PIN6: +V GS PIN5: +V VS PIN4: PS ON/OFF PIN3: AC OK PIN2: DC OK PIN1: GND NC 3 Neutral 4 NC 5 Line Note: VS means Remote Sense ”+” GS means Remote Sense “Return” (DC Output, T.B.) PIN NO. ASSIGNMENT 1 +V 2 +V 3 PWR GND 4 PWR GND CN3,CN4,CN5 (FAN Output) PIN NO. ASSIGNMENT 1 +12V(FAN) 2 GND(FAN) Rated Load (W CN2 200 175 150 125 100 75 50 25 0 With 30CFM Forced Air Convection Cool 0 10 20 30 40 50 60 70 80 Ambient Temperature (Deg.C) Fig.3. Output Derating Curve 2006/11/06 Ver. 19.0 AC100X SERIES AC100X12 AC100X15 AC100X20 AC100X24 AC100X48 1400 PROVIDENCE HIGHWAY • BUILDING 2 NORWOOD, MASSACHUSETTS 02062-5015 PHONE: 781-551-5500 FAX: 781-551-5555 AC100X SERIES AC100 SERIES Rev C December 2007 ISOLATED AC-DC Converter AC100 SERIES APPLICATION NOTE Rev C Page 1 AC100 SERIES Rev C December 2007 Content 1. INTRODUCTION 2. AC100 CONVERTER FEATURES 3. GENERAL DESCRIPTION ABSOLUTE MAXIMUM RATINGS 3 3 3 4 5. MAIN FEATURES AND FUNCTIONS 5.1 Operating Temperature Range 6 6 5.2 Output Voltage Adjustment 6 5.3 Over Current Protection 6 5.4 Over Voltage Protection 6 5.5 V-Sense 6 6. SAFETY 7. APPLICATIONS 7.1 Power De-Rating Curves 6 6 7 7.2 Efficiency vs. Load Curves 9 7.3 Test Set-Up 11 7.4 Output Ripple and Noise Measurement 11 7.5 Output Capacitance 11 7.6 EMI 11 8. MECHANICAL OUTLINE DIAGRAMS 8.1 AC100 Mechanical Outline Diagrams 12 12 9.INSTALLATION INSTRUCTION 12 10. PART NIMBER 14 Page 2 AC100 SERIES Rev C December 2007 • Universal Input Range • Regulated Outputs This application note describes the features and functions of Intronics • Continuous Short Circuit Protection power’s AC100 series of open frame, Isolated AC-DC Converters. • 3” X 5” size These are highly efficient, reliable and compact, high power density, • Open-Frame Type 1. Introduction single output AC/DC converters. Ultra-high efficiency operation is achieved through the use of synchronous rectification and drive control techniques. The modules are fully protected against short circuit and over-voltage conditions. Intronics power’s world class automated 3. General Description manufacturing methods, together with an extensive testing and qualification program; ensure that all AC100 series converters are A block diagram of the AC100 series converter is shown in Figure 1. extremely reliable. Extremely high efficiency power conversion is achieved through the use of synchronous rectification and drive techniques. Essentially, the 2. AC100 Converter Features powerful AC100 series topology is based on an isolated synchronous • 100W Isolated Output stability, fast transient response and a very tight line and load • High Efficiency Up to 85% regulation. The output voltage can be adjusted from +5% to –5%, using • Fixed Switching Frequency a variable resistor. • Power factor correction Up to 0.9 AC Input forward converter. The control loop is optimized for unconditional Input Filter Bridge Rectifier MOSFET Switch PFC Controller PFC Choke & MOSFET Switch PWM Controller Transformer MOSFET Rectifier Optocoupler Isolation Output Filter Vout Refernce &Error AMP Figure 1. Electrical Block Diagram Page 3 AC100 SERIES Rev C December 2007 4. Technical Specifications (All specifications are typical at nominal input, full load at 25℃ unless otherwise noted.) PARAMETER ABSOLUTE MAXIMUM RATINGS NOTES and CONDITIONS Device Min. Typical Max. Units Input Voltage Continuous 90 264 Vdc Operating Temperature 0 +40 ℃ -20 +85 ℃ Vdc 240 63 Vac Hz A Storage Temperature Input/Output Isolation Voltage INPUT CHARACTERISTICS Operating Voltage Range Input Frequency Range Maximum Input Current Power factor correction 1 minute 4242 100 47 100% Load, Vin=90Vac 100% Load, Vin=Nominal Vin No-Load Input Power Vin=264Vac Leakage Current Inrush Current Vin=240Vac, cold 1.5 0.9 7.0 6.0 5.0 5.0 5.0 5.0 4.0 AC100S050 AC100S090 AC100S120 AC100S150 AC100S180 AC100S240 AC100S480 start at 250C. W 3.5 80 mA A 5.05 9.09 12.12 15.15 18.18 24.24 48.48 Vdc OUTPUT CHARACTERISTIC Output Voltage Set Point Vin=Nominal Vin , Io=Io.max, Tc=25℃ AC100S050 AC100S090 AC100S120 AC100S150 AC100S180 AC100S240 AC100S480 Operating Output Current Range Holdup Time Output Voltage Regulation AC100S050 AC100S090 AC100S120 AC100S150 AC100S180 AC100S240 AC100S480 Vin=115Vac 4.95 8.91 11.88 14.85 17.82 23.76 47.52 5.0 9.0 12.0 15.0 18.0 24.0 48.0 20.0 11.2 8.4 6.7 5.6 4.2 2.1 20 A mS Load Regulation 10% load to Full load ±1.0 % Line Regulation Vin=high line to low line ±0.5 % Output Voltage Ripple and Noise 20MHz bandwidth Full load, 0.1uF ceramic and 220uF E.L capacitor AC100S050 AC100S090 AC100S120 100 90 120 mV Full load, 0.1uF ceramic and 10uF E.L capacitor AC100S150 AC100S180 AC100S240 AC100S480 150 180 240 480 mV Peak-to-Peak Page 4 AC100 SERIES Rev C December 2007 PARAMETER NOTES and CONDITIONS Output Current-Limit Output Votage-Limit Turn-On Transient Start-Up Time, From Input Output Voltage =90% Nominal Output Voltage Maximum Output Capacitance Device Min. 110 110 Typical Max. 130 150 130 150 Vin=90Vac Vin=Nominal Vin at Full load 5 20000 12000 8400 6700 5600 4200 2100 AC100S050 AC100S090 AC100S120 AC100S150 AC100S180 AC100S240 AC100S480 Units % % s uF EFFICIENCY 100% Load ISOLATION CHARACTERISTICS Input to Output Input to Earth Output to Earth 82 AC100S090 AC100S120 AC100S150 AC100S180 AC100S240 AC100S480 85 85 85 85 85 85 1 minute 1 minute 1 minute Isolation Resistance FEATURE CHARACTERISTICS Switching Frequency Output Voltage Adjustment AC100S050 % 4242 2121 707 100 MΩ 67 Pout=max rated power Vdc Vdc Vdc -5 +5 KHz % GENERAL SPECIFICATIONS MTBF Weight Io=100%of Io.max;Ta=25℃ per MIL-HDBK-217F TBD M hours 0.385 Kg Page 5 AC100 SERIES Rev C December 2007 5. Main Features and Functions 5.1 Operating Temperature Range Intronics power’s AC100 series converters highly efficient converter design has resulted in its ability to operate ambient temperature environment (0℃ to 40℃). Due consideration must be given to the derating curves when ascertaining maximum power that can be drawn from the converter. The maximum power drawn is influenced by a 5.4 Over Voltage Protection All different voltage models have a full continuous over voltage protection. The power module will supply up to 150% of rated voltage. In the event of an over voltage converter will go into a hiccup mode protection. number of factors, such as: • Input voltage range. • Output load current. • These can be effective heat sinks for the converter. 5.2 Output Voltage Adjustment The output voltage on all models is in the range from +5% to –5% but can't exceed the watt value of the products . 5.3 Over Current Protection All different voltage models have a full continuous short-circuit 5.5 V-Sense V-sense measures the use as outputting the voltage. The maximum length of the sense lines is 1200mm. The min gauge wire that can be used 26AWG. If does not use and needn't need to join . 6. Safety CB Approval TUV Approval UL Approval protection. The unit will auto recover once the short circuit is removed. To provide protection in a fault condition, the unit is equipped with internal over-current protection. The unit operates normally once the fault condition is removed. The power module will supply up to 150% of rated current. In the event of an over current converter will go into a 7. Applications hiccup mode protection. Page 6 AC100 SERIES Rev C December 2007 7.1 Power De-Rating Curves g 100% 75% O u tp u t lo a d O u t p u t lo a d 100% 50% 25% 0% 0 10 20 30 40 50 60 75% 50% 25% 0% 70 0 Ambient temperature(oC) 20 30 40 50 70 60 o Ambient temperature( C) Figure 6a. Typical Power De-rating for AC100S050 Figure 6b.Typical Power De-rating for AC100S090 100% 75% 75% O u tp u t lo a d 100% O u tp u t lo a d 10 50% 25% 0% 50% 25% 0% 0 10 20 30 40 50 60 o Ambient temperature( C) Figure 6c.Typical Power De-rating for AC100S120 70 0 10 20 30 40 50 70 60 o Ambient temperature( C) Figure 6d.Typical Power De-rating for AC100S150 Page 7 AC100 SERIES Rev C December 2007 75% 75% O u tp u t lo a d 100% O u tp u t lo a d 100% 50% 25% 0% 50% 25% 0% 0 10 20 30 40 50 60 70 o 0 10 20 30 40 50 70 60 o Ambient temperature( C) Ambient temperature( C) Figure 6g.Typical Power De-rating for AC100S180 Figure 6h.Typical Power De-rating for AC100S240 g O u t p u t lo a d 100% 75% 50% 25% 0% 0 10 20 30 40 50 60 70 Ambient temperature(oC) Figure 6i.Typical Power De-rating for AC100S480 Page 8 AC100 SERIES Rev C December 2007 7.2 Efficiency vs. Load Curves AC100S090 AC100S050 95.0 90.0 90.0 85.0 Efficiency (% Efficiency (% 80.0 70.0 60.0 50.0 115VAC 75.0 70.0 65.0 60.0 230VAC 40.0 80.0 115VAC 55.0 30.0 1 2 3 4 5 6 7 8 230VAC 50.0 9 10 11 12 13 14 15 16 17 18 19 20 1 Output Current (A) 2 3 4 5 6 7 8 9 10 11 11.2 Output Current (A) Figure 7a. AC100S050 Figure 7b. AC100S090 AC100S150 AC100S120 95.0 95.0 90.0 90.0 Efficiency (%) Efficiency (% 85.0 80.0 75.0 70.0 65.0 60.0 115VAC 55.0 230VAC 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 Output Current (A) 6 6.5 7 7.5 8 80.0 75.0 70.0 65.0 115VAC 60.0 230VAC 55.0 50.0 0.5 85.0 8.5 50.0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 Output Current (A) Figure 7c. AC100S120 Figure 7d. AC100S150 Page 9 7 AC100 SERIES Rev C December 2007 AC100S240 AC100S180 95.0 95.0 90.0 90.0 85.0 Efficiency (% 80.0 75.0 70.0 65.0 60.0 115VAC 230VAC 55.0 80.0 75.0 70.0 65.0 60.0 115VAC 55.0 230VAC 50.0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 Output Current (A) 5.6 50.0 0.5 1 1.5 2 2.5 3 3.5 4 4.2 Output Current (A) Figure 7g. AC100S180 Figure 7h. AC100S240 AC100S480 95.0 90.0 85.0 Efficiency (% Efficiency (% 85.0 80.0 75.0 70.0 65.0 60.0 115VAC 55.0 230VAC 50.0 0.25 0.5 0.75 1 1.25 1.5 1.75 2 2.1 Output Current (A) Figure 7i. AC100S480 Page 10 AC100 SERIES Rev C December 2007 7.3 Test Set-Up 7.4 Output Ripple and Noise Measurement The basic test set-up to measure parameters such as efficiency and The test set-up for noise and ripple measurements is shown in Figure load regulation is shown in Figure 8. When testing the Intronics power’s 10. Measured method : AC100 series under any transient conditions please ensure that the Add a terminal wire is 50mmMIN that the output end needs to connect transient response of the source is sufficient to power the equipment the sub length of line of one end . under test. We can calculate the 1. Add a 0.1 uF ceramic capacitor and a 220 uF electrolytic capacitor • Efficiency • Load regulation and line regulation. to output at 20 MHz Band Width for AC100S050 , AC100S090 and AC100S120. The value of efficiency is defined as: 2. Add a 0.1 uF ceramic capacitor and a 10 uF electrolytic capacitor to output at 20 MHz Band Width for AC100S150 , AC100S180 , η= Where: Vo × Io × 100% Pin AC100S240 and AC100S480. Terminal wire Vo is output voltage, AC Io is output current, L Loa +Vo + Pin is input power, Suppl Oscillosco 0.1uF N -Vo The value of load regulation is defined as: Load .reg = VFL − VNL ×100% VNL 10uF/100V or220uF/35V AC100 Figure 10. Output Voltage Ripple and Noise Measurement Set-Up Where: VFL is the output voltage at full load VNL is the output voltage at 10% load 7.5 Output Capacitance Intronics power’ AC100 series converters provide unconditional stability The value of line regulation is defined as: Line.reg = with or without external capacitors. Intronics power’ converters are VHL − VLL ×100% VLL designed to work with load capacitance up-to 1000uF per amp. Where: VHL is the output voltage of maximum input voltage at full load. VLL is the output voltage of minimum input voltage at full load. L A +Vo 7.6 EMI Conductive EMI meets CISPR/FCC Class B AC V Pin Supply N Load -Vo Figure 8. AC100 Series Test Setup Page 11 AC100 SERIES Rev C December 2007 8. Mechanical Outline Diagrams 8.1 AC100 Mechanical Outline Diagrams Dimensions are in millimeters Tolerance: x.x ±0.5mm, unless otherwise noted Annotations:All models height does not exceed 34mmMAX . for AC100S050 Figure 11. AC100 Mechanical Outline Diagram 9. Installation Instruction Please use the mounting hold as: AC100S series : 4 holds of ψ 3.17 And insert the spacer (Maxψ 6) of height over 8mm to lift the unit .The vibration spec. is the value take when the unit is raised by 8mm spacers. Page 12 AC100 SERIES Rev C December 2007 Please reserve 4mm space from the surfaces and the sides of PCB, especially from the solder surface, 8mm space is necessary. If the space is not enough, the specification of insulation and withstand will not be satisfied. FG should be connected to the earth terminal of the apparatus. If not, the conducted noise and output noise will increase. Page 13 AC100 SERIES Rev C December 2007 10. Part Number AC – XXX S XXX AC SERIES 100: Supply Max. Power S: Single Output 050:Output Voltage 5.0 VDC 090:Output Voltage 9.0 VDC 120:Output Voltage 12 VDC 150:Output Voltage 15 VDC 180:Output Voltage 18 VDC 240:Output Voltage 24 VDC 480:Output Voltage 48 VDC INTRONICS POWER INCORPORATED. Page 14 ® 1400 PROVIDENCE HIGHWAY • BUILDING 2 NORWOOD, MASSACHUSETTS 02062-5015 AC60 Single Rev A January 2007 AC-DC Switching Power Module AC60 series APPLICATION NOTE Rev A Page 1 ® AC60 Single 1400 PROVIDENCE HIGHWAY • BUILDING 2 Rev A January 2007 NORWOOD, MASSACHUSETTS 02062-5015 Content 1. INTRODUCTION 2. AC60 SERIES CONVERTER FEATURES 3. TECHNICAL SPECIFICATIONS 4. MAIN FEATURES AND FUNCTIONS 3 3 4 5 4.1 Operating Temperature Range 5 4.3 Output Protection 5 5. SAFETY 6. APPLICATIONS 5 5 6.1 Power De-Rating Curve 5 6.2 Test Set-Up 6 6.3 Output Ripple and Noise Measurement 6 6.4 Installation Instruction 6 7. AC60 SERIES MECHANICAL OUTLINE DIAGRAMS 8. PART NUMBER 7 8 Page 2 ® AC60 Single 1400 PROVIDENCE HIGHWAY • BUILDING 2 Rev A January 2007 NORWOOD, MASSACHUSETTS 02062-5015 1. Introduction 2. AC60 series Converter Features This application note describes the features and functions of Intronics AC60 series of open frame, switching AC-DC power module. These are highly efficient, reliable and compact, high power density, single output AC/DC power module. The module is fully protected against short circuit and over-voltage conditions. Intronics world class automated manufacturing methods, together with an extensive testing and qualification program; ensure that the AC60S480 power module is extremely reliable. • 60W Isolated Output • High Efficiency Up to 88% • Fixed Switching Frequency • Universal Input Range • Regulated Output • Continuous Short Circuit Protection • 2” X 4” size, low profile • Open-Frame Type Page 3 ® AC60 Single 1400 PROVIDENCE HIGHWAY • BUILDING 2 Rev A January 2007 NORWOOD, MASSACHUSETTS 02062-5015 3. Technical Specifications (All specifications are typical at nominal input, full load at 25℃ unless otherwise noted.) PARAMETER ABSOLUTE MAXIMUM RATINGS Input Voltage Continuous Operating Temperature Storage Temperature Input/Output Isolation Voltage INPUT CHARACTERISTICS Operating Voltage Range Input Frequency Range Maximum Input Current Leakage Current Inrush Current OUTPUT CHARACTERISTIC Output Voltage Set Point NOTES and CONDITIONS Device 1 minute Typical Units 90 0 -20 4242 264 +50 +85 Vac ℃ ℃ Vdc 100 47 240 63 Vac Hz A mA A 1.4 3.5 50 Vin=264Vac, cold start at 250C. AC60S033 AC60S050 AC60S090 AC60S120 AC60S150 AC60S240 AC60S280 AC60S360 AC60S480 AC60S033 AC60S050 AC60S090 AC60S120 AC60S150 AC60S240 AC60S280 AC60S360 AC60S480 Vin=Nominal Vin , Io=Io.max, Tc=25℃ Holdup Time Vin=115Vac Output Voltage Regulation Load Regulation Line Regulation 10% load to Full load Vin=high line to low line Output Voltage Ripple and Noise 20MHz bandwidth ISOLATION CHARACTERISTICS Input to Output Input to Earth Output to Earth Isolation Resistance Max. 100% Load, Vin=90Vac Operating Output Current Range Peak-to-Peak Min. Full load, 0.1uF ceramic and capacitor 3.26 4.95 8.91 11.88 14.85 23.76 27.72 35.64 47.52 3.3 5.0 9.0 12.0 15.0 24.0 28.0 36.0 48.0 8 8 6.67 5 4 2.5 2 1.67 1.25 8 3.33 5.05 9.09 12.12 15.15 24.24 28.28 36.36 48.48 Vdc A mS ±1.0 ±0.5 10uF E.L % % AC60S033 AC60S050 AC60S090 AC60S120 50 50 90 120 AC60S150 AC60S240 AC60S280 AC60S360 AC60S480 150 240 280 360 480 mV 4242 2121 707 Vdc Vdc Vdc MΩ 1 minute 1 minute 1 minute 100 FEATURE CHARACTERISTICS Switching Frequency 60 KHz GENERAL SPECIFICATIONS MTBF Weight Io=100%of Io.max;Ta=25 MIL-HDBK-217F ℃ per TBD 0.175 M hours Kg Page 4 ® 1400 PROVIDENCE HIGHWAY • BUILDING 2 NORWOOD, MASSACHUSETTS 02062-5015 AC60 Single R ev A January 2007 4. Main Features and Functions 6. Applications 4.1 Operating Temperature Range 6.1 Power De-Rating Curve Intronics AC60 series power modules, which highly efficient design, has resulted in its ability to operate ambient temperature environment (0℃ to 50℃). Due to consideration must be given to the de-rating curves when ascertaining maximum power that can be drawn from the power module. The maximum power drawn is influenced by a number of factors, such as: • Input voltage range. • Output load current. • These can be effective heat sinks for the power module. 4.3 Output Protection The power modules provide a full continuous short-circuit protection. The unit will auto recover once the short circuit is removed. To provide protection in a fault condition, the unit is equipped with internal over-current protection. The unit will operate normally once the fault condition is removed. The power module will go to hiccup mode if the output current or voltage is set from 110% to 150% of rated current or voltage. 5. Safety CB TUV Approval Approval UL Approval CE Approval Page 5 ® AC60 Single 1400 PROVIDENCE HIGHWAY • BUILDING 2 NORWOOD, MASSACHUSETTS 02062-5015 Rev A January 2007 6.2 Test Set-Up 6.3 Output Ripple and Noise Measurement The basic test set-up to measure parameters such as efficiency and The test set-up for noise and ripple measurements is shown in Figure 2. load regulation is shown in Figure 1. When testing the Intronics AC60 Measured method : series under any transient conditions, please ensure that the Add a 0.1 uF ceramic capacitor and a 10 uF electrolytic capacitor to output at 20 MHz Band Width. transient response of the source is sufficient to power the equipment under test. We can calculate the • Efficiency • Load regulation and line regulation. Terminal wire 800mmMin The value of efficiency is defined as: L +Vo AC Where: Supply Load N 0.1uF -Vo 10uF/100V Vo is output voltage, AC60S Series Io is output current, Figure 2. Output Voltage Ripple and Noise Measurement Set-Up Pin is input power, The value of load regulation is defined as: 6.4 Installation Instruction V FL -V Load reg = NL × 100% V + Oscilloscope Vo × η= Io × 100% Pin Please use the mounting hold as: AC60 series : 4 holds of ψ3.17 And insert the spacer (Maxψ6) of height over 8mm to lift the unit .The vibration spec. is the value take when the unit is raised by 8mm spacers. NL Where VFL is the output voltage at full load VNL is the output voltage at 10% load The value of line regulation is defined as: − Line reg = V HL V V LL LL × 100% Where VHL is the output voltage of maximum input voltage at full load. VLL is the output voltage of minimum input voltage at full load. AC L +Vo N -Vo V Pin Supply A Load + Figure 1. AC60 Series Test Setup Page 6 ® 1400 PROVIDENCE HIGHWAY • BUILDING 2 NORWOOD, MASSACHUSETTS 02062-5015 Please reserve 4mm space from the surfaces and the sides of PCB, especially from the solder surface, 8mm space is necessary. If the space is not enough, the specification of insulation and withstand will not be satisfied. AC60 Single Rev A January 2007 7.AC60 Series Mechanical Outline Diagrams Dimensions are in millimeters Tolerance: x.x ±0.5mm, unless otherwise noted Annotations:All models height does not exceed 34mmMAX . FG should be connected to the earth terminal of the apparatus. If not, the conducted noise and output noise will increase. Figure 6. AC60 series Mechanical Outline Diagram Page 7 ® AC60 Single 1400 PROVIDENCE HIGHWAY • BUILDING 2 Rev A January 2007 NORWOOD, MASSACHUSETTS 02062-5015 8. Part Number AC XX S XXX AC SERIES 60: Supply Max. Power S:Single Output • • • • • • • • • 033:Output Voltage3.3 VDC 050:Output Voltage 5.0 VDC 090:Output Voltage 9.0 VDC 120:Output Voltage 12 VDC 150:Output Voltage 15 VDC 240:Output Voltage 24 VDC 280:Output Voltage 28 VDC 360:Output Voltage 36 VDC 480:Output Voltage 48 VDC Page 8 AC10 / 15