High Speed Fuses For the Protection of Power Semiconductors February 1998 Bussmann® Ferrule Introduction Table of Contents Catalog Symbol General Information Ampere Range Page FWA 150V 5-60A 80 FWX 250V 1-30A 81 FWH 500V 0.25-30A 82-83 FWC 600V 6-32A 84 FWP 660V/700V 1-100A 85-86 FWK 750V 5-60A 87 FWJ 1000V 20-30A 88 FWL/FWS 1250V/1500V 2-30A 89 Accessories Fuseholders 90 Curves Time-Current & Peak Let-Through Voltage 150 250 500 600 700 700 750 800 1000 1000 1250 1500 91-96 AC X X X X X — — — X — X X DC — X X — — X X X — X — — Ampere Range 5-60 1-30 0.25-30 6-32 1-100 1-30 5-60 20-30 20-30 2-30 20-30 2-15 Select fuses designed and tested to: • IEC 269: Part 4 • U.L. Recognized Bussmann offers a full line of ferrule style (cylindrical and clip-mounted) fuses, designed and tested to meet standards and requirements in various locations around the world. Their unique design and construction provide: • Superior cycling capability • Low energy let-through (I2t) Ferrule fuses provide an excellent solution for small UPS, small AC drives and other low power applications where space is at a premium. Voltage Rating All Bussmann ferrule fuses — except 660 volt — have been tested at their rated voltage. The 660 volt ferrule fuse has been tested to the IEC 269 standard, which requires clearing at the rated voltage +10%. Accessories Ferrule fuses may be mounted in fuseclips, fuseholders, fuseblocks or fused switches. A variety of products are available to suit most end-use requirements. For complete specification data, visit our Web site at www.bussmann.com or call Bussmann Information Fax ~ 314.527.1450 79 Bussmann® Ferrule 20-100A FWP 660V/700V (IEC/U.L.) Size Electrical Characteristics I2t (A2S) Rated Current Clearing RMS-Amps Pre-arc at 660V 20 23 25 37 32 55 22 ≈ 58mm 40 68 (‡Ω•∑) 50 155 63 280 80 600 100 1100 䡲 Interrupting rating 200kA RMS Symmetrical. 䡲 Watts loss provided at rated current. 䡲 Consult Bussmann for DC ratings. 䡲 See accessories on page 90. ® Ordering Information 260 410 605 750 1600 3080 6600 12500 Watts Loss Part Number Carton Qty. Carton Weight (kg) 4.6 5.6 7.0 8.5 9.5 11 13.5 16 FWP-20A22F FWP-25A22F FWP-32A22F FWP-40A22F FWP-50A22F FWP-63A22F FWP-80A22F FWP-100A22F 10 0.450 Dimensions Curves Figure Number See Page or (BIF #) page 95 (35785291) Fig. 1 1 kg = 2.2 lbs. 1 lb = 0.45 kg Dimensions Fig. 1: 20-100 Amp Range 58.0 (2.283") 22.2 (0.875") 15.0 (0.591") Dimension in mm. 1mm = 0.0394∑ 1∑ = 25.4mm Electrical Characteristics Total Clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, E g , (RMS). 1.4 1.2 1.0 0.9 0.8 0.7 0.6 Arc Voltage This curve gives the peak arc voltage, U L , which may appear across the fuse during its operation as a function of the applied working voltage, E g , (RMS) at a power factor of 15%. 1.4 1.2 103 9 8 7 6 K 0.5 5 0.4 4 0.3 200 300 400 500 600 1.0 Kp 0.8 UL 0.6 0.5 0.4 0.3 0.2 Eg Eg 3 700 Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current . The correction factor, K p , is given as a function of the RMS load current, Ib , in % of the rated current . 200 300 400 500 600 700 0.1 30 40 50 Ib 60 70 80 90 100% BIF document: 720026 86 For complete specification data, visit our Web site at www.bussmann.com or call Bussmann Information Fax ~ 314.527.1450 Bussmann® Ferrule – Accessories Fuseholders ® Catalog Symbol: CH Series Features: • 10 ≈ 38 Dovetail design provides maximum flexibility in assembling multiple poles • Touchsafe design - No exposed contacts • DIN rail mount (35mm) • Optional open fuse indication lights • Excellent for switchboard panel, control consoles, small motors, transformers, and similar applications • Handle/fusepuller to install and remove fuses easily • Available in single and multi-pole configurations • Circuit marking system (P/N CH10CL and CH10CM) • Wire ready: Saves time as terminals are ready to accept wires. • CE marking Standards: North American 10 ≈ 38 Class CC Listed U.L. 512, Guide IZLT, File E14853 Certified CSA Std. C22.2 No. 39, Class 6225 01, File 47235 North American 10 ≈ 38 Midget Recognized U.L. 512, Guide IZLT2, File E14853 Certified CSA Std. C22.2 No. 39, Class 6225 01, File 47235 European 10 ≈ 38 IEC 269-2-1 14 ≈ 51 IEC 269-2 22 ≈ 58 IEC 269-2 Recommended Buss® Fuse Types: 10 ≈ 38 North American Class CC Fuses - LP-CC, FNQ-R, KTK-R 10 ≈ 38 North American Midget Fuses - FNQ, KTK, AGU, BAF, BAN, FNM, FWA, & FWC 14 ≈ 51 Fuses - FWX, FWH, FWP & NON 22 ≈ 58 Fuses - FWP BIF document: 1151 Catalog Symbol: J70100 Ampere Rating: 100 Amperes Voltage Rating: 700 Volts AC Agency Approvals: UL Recognized, Guide IZLT2, File E14853 Withstand Rating: 200,000 RMS Sym. Amps For use with 22 ≈ 58mm fuses (FWP-40A22F, FWP-100A22F, etc.) Materials: Thermoplastic UL Flammability: 94 VO Amps 100 Poles 1 2 3 Catalog Numbers Box Lug w/ Retaining Clip J70100-1CR J70100-2CR J70100-3CR Max. Wire Size #2 #2 #2 BIF document: 1211 90 For complete specification data, visit our Web site at www.bussmann.com or call Bussmann Information Fax ~ 314.527.1450 Modular Fuseholders Bussmann® 10 ≈ 38, 14 ≈ 51, 22 ≈ 58 Features: • 10 ≈ 38 Dovetail design provides maximum flexibility in assembling multiple poles • Touchsafe design - No exposed contacts • DIN rail mount (35mm) • Optional open fuse indication lights • Excellent for switchboard panel, control consoles, small motors, transformers, and similar applications • Handle/fusepuller to install and remove fuses easily • Available in single and multi-pole configurations • Circuit marking system (P/N CH10CL and CH10CM) • Wire ready: Saves time as terminals are ready to accept wires. • CE marking CH Series Standards: North American 10 ≈ 38 Class CC Listed U.L. 512, Guide IZLT, File E14853 Certified CSA Std. C22.2 No. 39, Class 6225-01, File LR47235 North American 10 ≈ 38 Midget U.L. Recognized 512, Guide IZLT2, File E14853 CSA Certified, Std. C22.2 No. 39, Class 6225-01, File LR47235 European 10 ≈ 38 IEC 269-2-1 14 ≈ 51 IEC 269-2*** U.L. Recognized, CSA Certified 22 ≈ 58 IEC 269-2*** U.L. Recognized, CSA Certified Recommended Buss® Fuse Types: 10 ≈ 38 North American Class CC Fuses - LP-CC, FNQ-R, KTK-R 10 ≈ 38 North American Midget Fuses - FNQ, KTK, AGU, KLM, BAF, BAN, FNM, FWA, FWC, & FNQ 14 ≈ 51 Fuses - FWX, FWH, FWP & NON 22 ≈ 58 Fuses - FWP Specifications Fuse Size (mm) Voltage Amperage U.L./CSA*** IEC U.L./CSA*** IEC Wire Size Wire Type (& Temp.) Torque (in-lbs) IP Rating Contact Material (fuseclip) Connector Material Maximum Watts Loss of Fuse Dual Wire Rating 10 ≈ 38 Description 1 Pole 1 Pole w/Indication 2 Pole 2 Pole w/Indication 3 Pole 3 Pole w/Indication *Assembly Pins - 2 Poles *Assembly Pins - 3 Poles **Circuit markers **Circuit marker labels Spare Fuseholder 30A, 600V North American Class CC Fuseholder CHCC1 CHCC1I CHCC2 CHCC2I CHCC3 CHCC3I CH102AP CH103AP CH10CM CH10CL 5TPH 10 ≈ 38 600V 690V 30A 32A #8 - #18 Cu only Solid/Stranded (75°) 12 in-lbs IP 20 Tin-plated copper Steel 3W‡ Please consult factory 30A, 600V North American Midget Fuseholder CHM1 CHM1I CHM2 CHM2I CHM3 CHM3I CH102AP CH103AP CH10CM CH10CL 5TPH 32A, 690V European 10 ≈ 38 Fuseholder CH101 CH101I CH102 CH102I CH103 CH103I CH102AP CH103AP CH10CM CH10CL 5TPH ‡Refer to BIF documents 720003, 720008, 720025 and 720028 for watts loss of applicable fuses. *CH102AP and CH103AP are packaged in quantities of ten pins. One pin is required to gang units together, and rating multiple poles. **CH10CM are packaged in quantities of ten. CH10CL are packaged in quantities of ten sheets of labels. ***U.L./CSA part numbers include U.L. suffix. 12-17-98 SB98107 Rev. A 14 ≈ 51 750V*** 660V 30A*** 50A(See Watts Loss) #6 - #14 Cu only Solid/Stranded (75°) 17.7 in-lbs IP 20 Tin-plated copper Steel 5W‡ Description 1 Pole 1 Pole w/U.L. markings 1 Pole w/microswitch 2 Pole 3 Pole 3 Pole w/U.L. markings 3 Pole w/microswitch Handle Profile - 2 Poles Handle Profile - 3 Poles 22 ≈ 56 750V*** 660V 50A*** 125A(See Watts Loss) #1 - #14 Cu only Solid/Stranded (75°) 22.1 in-lbs IP 20 Tin-plated copper Steel 9.5W‡ 14 ≈ 51 Part No. Ctn. Qty. CH141G 6 CH141GUL 6 CH141MSG 6 CH142G 3 CH143G 2 CH143GUL 2 CH143MSG 2 CH142HCG 10 CH143HCG 10 22 ≈ 58 Part No. Ctn. Qty. CH221G 6 CH221GUL 6 CH221MSG 6 CH222G 3 CH223G 2 CH223GUL 2 CH223MSG 2 CH222HCG 10 CH223HCG 10 CE logo denotes compliance with European Union Low Voltage Directive (50-1000 Vac, 75-1500 Vdc). Refer to BIF document #8002 or contact Bussmann Application Engineering at 314-527-1270 for more information. Form No. CH Series Page 1 of 2 BIF Doc #1151 Modular Fuseholders Bussmann® 10 ≈ 38, 14 ≈ 51, 22 ≈ 58 CH Series Size: 10 ≈ 38 Fuseholder G E A in (mm) in (mm) A 2.26 (57.5) G 2.07 (52.5) B 1.73 (44.0) H 0.75 (19.0) C 1.78 (45.2) I 0.69 (17.5) D 1.97 (49.9) J 1.38 (35.0) E 3.24 (82.2) K 3.18 (80.7) F 0.24 (6.0) L 0.30 (7.6) in (mm) in (mm) A 0.98 (26.0) I 3.50 (89.0) B 2.05 (52.0) J 0.20 (5.0) C 3.07 (78.0) K 1.28 (32.5) E 3.19 (81.0) L 3.86 (98.0) F 2.11 (53.5) M 4.17 (106.0) G 1.75 (44.5) N 0.83 (21.0) H 2.07 (52.6) O 1.72 (43.8) in (mm) in (mm) A 1.38 (35.0) I 4.06 (103.0) B 2.76 (70.0) J 0.18 (4.5) C 4.13 (105.0) K 1.77 (45.0) E 3.46 (88.0) L 4.41 (112.0) F 2.09 (53.0) M 5.51 (140.0) G 1.77 (45.0) N 1.04 (26.5) H 2.28 (58.0) O 2.48 (63.0) H J I F B K C D L Size: 14 ≈ 51 Fuseholder L C E A F B J J K K M M G O O N G H Size: 22 ≈ 58 Fuseholder L C E F A B J J K M K M G O G H N O N I The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 12-17-98 SB98107 Rev. A Form No. CH Series Page 2 of 2 BIF Doc #1151 Bussmann® Semiconductor Fuseblocks J70100 Series 700 Volt, 100 Amps Catalog Symbol: J70100 Ampere Rating: 100A Voltage Rating: 700Vac Agency Information: UL Recognized, Guide IZLT2, File E14853 Withstand Rating: 200,000 RMS Sym. Amps For use with 22 ≈ 58mm fuses (FWP-40A22F, FWP-100A22F, etc.) Materials: Thermoplastic UL Flammability: 94VO Amps 100 Poles 1 2 3 Catalog Numbers Box Lug w/ Fig. Wire Retaining Clip No. Range J70100-1CR 1 #2-14 CU/AL J70100-2CR 2 #2-14 CU/AL J70100-3CR 3 #2-14 CU/AL Dimensional Data 100A 1.702 3.202 .750 2.250 2.415 4.702 2.250 .750 C L 3.994 CL 1.500 FIGURE 1 FIGURE 2 FIGURE 3 The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 9-18-02 SB02295 Form No. J70100 Page 1 of 1 Data Sheet: 1211