Sino-German CGIS (Shanghai) Electrics Ltd. Add: 868 Jiahang Rd., Jiading, Shanghai 201808 P. R. China Tel:+86-21-69900886 69900810 Fax:+86-21-69900254 Http://www.cgis.cn E-mail:cgis@cgis.cn We reserve the right to make technical changes or modify the contents of this document without prior notice. All the agreed particulars shall prevail. All rights reserved. CGIS (Shanghai) Electrics Ltd. Copyright C 2006.08 CGIS-EC-008-08-2006 N2S / N2X Environment-friendly Gas Insulated Metal-enclosed Switchgear N2X N2SN2X Contents SINO-GERMAN CGIS (SHANGHAI) ELECTRICS LTD. N2S/N2X General 1 N2S/N2X Applications 2 N2S/N2X Product Advantages 3 N2S/N2X Main Components 4 N2S Technical Specifications 5 N2S Panel Structure 6 N2S OEM Functional Unit 7/8 N2S Typical Schemes 9/11 N2X Technical Specifications 12 N2X Panel Structure 13 N2X OEM Functional Unit 14/15 N2X Typical Schemes 16/18 N2S/N2X Application Schemes 19 N2S/N2X Foundation Frame 20/23 N2S/N2X General Normal Operating Conditions About CGIS Complying with: Busbar connector between Ambient temperature: CGIS (Shanghai) Electrics Ltd. China standards: GB3906, GB/ panels provides the easy Maximum temperature +40℃ Is a hi-tech enterprise set up T11022, DL/T593, DL/T404 etc. i n s t a l l a t i o n a n d f l e x i b l e Minimum temperature -25℃ extension, which eliminates Altitude the tre a t m e n t in the gas Up to 1000m* system. Environment W o r l d first-clas s m a n u The installation site shall not facturing technology such as suffer distinctive pollution laser welding, laser cutting by Shanghai Tianling Switchgear International standards: IEC62271-200 and IEC62271100 etc. Environment-friendly switchgear-non or less SF6. mainly engages in the business of research, development, manufacture and sales 12kV40.5kV meta l-enclosed gas and helium leakage detecting caused by corrosive or insulated switchgear. The dimension and less space technology imported fr o m flammable gas, vapor etc. leading products, N2S/N2X requirement. The width of Germany ensures the strict 500mm while the width of 40.5kV panel is only 600mm. gas insulated switchgear are German process and non- *Note: Please consult the designed by German switchgear fault operation of switchgear. manufacturer when the specialists, integrated with altitude >1000m new material, new process All high voltage elements are and new technology such as completely sealed from ambient the most advanced computer air and therefore not influenced by the environment. Any accidents caused by congeal dew, dust, small animals or If the operating conditions exceed the normal condi- forever. The VEG vacuum circuit tions listed in GB3906 or IEC breaker used in this switchgear 62271-200, please contact Maglev Train Subway our technical department. technology in electric power system, high voltage insulation technology, gas-tight technology and so on. The products have the advantages of high reliability, maintenance free, less space requirements, vacuum interrupter technology, environmentally friendly to meet the embedded pole design and the requirements of distribution a reliable magnetic or spring automation and high reliable Applications operation. All the products have operated manually or by a The products have been widely XIHARI, the China national motor drive. used in the fields of electric laboratory which is the member Compact gas tank structure. power, mine, oil, metallurgy, of international organization Suitable schemes can be railway, highway, harbor, archi- CNAL as well as IPH, German chosen depending on the tecture and petrochemistry etc. national laboratory. detailed requirements to The significant projects CGIS driving mechanism. Grand Theatre control technology, and sensor Special Operating Conditions chemical vapors are excluded combines t h e most modern Applications Co.,Ltd and DECOM GmbH and Compact switchgear : Small 12kV and 24kV panel is only N2S/N2X Substation p a s s e d t h e t y p e t e s t s in 3-position switch can be ensure t he reli a b l e a n d achieved are Shanghai Shimao economic operation. North Bund Plaza, Shanghai Intelligent control and protection Yanchuang Substation, Shanghai unit has varied function such Zhongxia Substation, Shanghai as control, protection, measure- Qingnan Substation etc. Architecture Bridge Harbor m e n t a n d c o m m u n i c a t i o n, Petrochemistry meeting the requirements of distribution automation. Railway Reliable mechanical and electric interlocking has prevented the maloperation effectively. 1 Highway 2 N2S/N2X Product Advantages EnvironmentFriendly N2S/N2X Main Components The Middle PanelWithdrawable OEM Gas Tank IST 3-position Switch VEG Embedded Pole Circuit Breaker Earthing function can be realized with 3- SF6 is one of the six kinds of position switch and circuit breaker. gases which have been regarded 1.Vacuum circuit breaker has as the restricted emission gas by t h a n conventional earthing switch, Kyoto Protocol. According to the which makes earthing short-circuit research by scientists, the green become more easil y v i a vacuum house effect of SF6 is 23,900 circuit breaker. times more than that of CO2. It 2.More operations can be done for fault will remain up to 3200 years current. N2S circuit breaker gas tank after its emission to the atmos- 3.Arc is limited in the vacuum interrupter, which reduces the exhaust of insulation phere. Due to its good arcing and insulation performance, N2S 3-position Switch N2S circuit breaker gas. SF6 has been using widely in 3-position switch is vertically arranged the HV and MV electrical industry. CGIS (Shanghai) Electrics Ltd. engages in the business of environmental protection by using non or less SF6 gas insulation. N2S/N2X gas insulated switchgear is just designed to meet this requirement. for N2S and horizontally arranged for For N2S: N2X. Silicon rubber bus bar connector The cylinder type 3-position switch is used to connect the upper driven by motor has the functions as gas tank, lower gas tank and follows : between panels. 1.Connecting, disconnecting and earthing When replacing or maintenance N2S busbar gas tank a single circuit breaker or position. "closed" (connected); Earthing switch remain in service. "closed" (earthed) position. replaced or maintained. as N2S, but with higher performance at lower cost. ensures the operation can be realized for N2S and horizontally arranged for The middle panel can be only in the opening position of circuit N2X. withdrawn while other neighbour breaker, which prevents the maloperation. Circuit breaker is embedded-pole N2X gas tank position without removing the cables. Provide OEM gas tank Provide technical support and training After-sales service will be provided by qualified Driving mechanism is accessible outside type with epoxy APG process. the gas tank and the insulation axis driven Driving mechanism is accessible by motor can realize the movement of outside the gas tank. movable contact. Earthing switch can be cancelled or blocked in 3-position switch on request. 3-position switch can be operated manually and added padlocks as per and trained personnel to special requirement. OEM partners It is equipped with mechanical position indicator. 3 500 1200 2250 630 ≥1600 800 1500 2250 980 ≤1250 500 1200 2250 630 ≥1600 800 1500 2250 980 ≤1250 600 1500 2400 880 ≥1600 800 1600 2500 1100 ≤1250 500 1050 2250 530 ≥1600 800 1400 2250 880 Sealed bushing is used to connect the embedded pole of circuit breaker ≤1250 500 1050 2250 530 and the rod of driving mechanism. ≥1600 800 1400 2250 880 24 40.5 N2X Switchgear N2X has the same function Circuit breaker is vertically arranged For N2S/N2X: panels can remain in original ≤1250 N2X circuit breaker N2S Switchgear and the main busbar can Weight W D H a c (kg) b (mm) (mm) (mm) Approx. 12 3.The other two positions: Disconnector Mechanical and electrical interlocking of N2S ensures it easy to be Rated Rated voltage current position. tank, other neighbor panels Separate gas tank structure Dimension & Weight of N2S/N2X Switchgear 2.The middle position is disconnecting outgoing cable on upper gas Compact Design more advantageous in making capability 12 24 Interlocking device ensures that the closing operation can only be realized when the 3-position switch is in its proper position, which prevents the maloperation. 4 N2S Technical Specifications Item No. N2S Panel Structure Data (IEC/GB) Unit 1 14 1 Rated voltage Between phases and to earth 2 Rated power frequency withstand voltage (1min) Rated lightning impulse withstand voltage Between phases and to earth 3 kV Across the isolating distance Across the isolating distance 12 17.5/24 36/38/40.5 28/42 50 95 2 32/48 60 118 3 75 125 185 85 145 215 15 kV kV 16 4 5 6 4 Rated frequency Hz 50, 60 5 Rated current A 630,800,1250,1600,2000,2500 6 Making single/back to back capacitor bank current A 630/400 400/400 400/400 7 Rated short-circuit breaking current kA 25/31.5/40 20/25/31.5 20/25/31.5 8 Rated short-circuit making current (peak) kA 63/80/100 50/63/80 50/63/80 7 17 8 9 Rated short-time withstand current/ duration 18 19 10 20 11 kA/s 25/3, 31.5/3, 40/3 20/3, 25/3, 31.5/3 10 Rated peak withstand current kA 11 Rated capacitor bank inrush making capacity kA 12 Rated cable-charging breaking current A 13 Rated operating sequences 14 Rated filling gas pressure (abs,20℃) MPa 0.12 15 Alarm pressure (abs,20℃) MPa 0.11 16 Minimum operating pressure (abs,20℃) MPa 0.10 17 Annual leakage rate %/Y 18 Degree of protection 63/80/100 20/3, 25/3, 31.5/3 50/63/80 50/63/80 21 12 22 20 23 13 25 31.5 24 50 O-0.3s-CO-3min-CO <0.1 High voltage live parts IP65 Low voltage compartment IP4X 19 Rated voltage of auxiliary circuit V 20 Rated power frequency withstand voltage of auxiliary circuit (1 min) kV *Note: The insulating level is tested under 0.1 MPa or 1 bar (abs. 20℃) of insulating gas. 5 9 DC24, 48, 110, 220 2 AC220 1. Protection and control unit 13. Framework 2. Low voltage compartment 14. Voltage transformer (Optional) 3. Vacuum circuit breaker mechanism 15. Pressure relief of circuit breaker gas tank 4. Vacuum circuit breaker 16. Feeder bus 5. Low voltage compartment door 17. Inner-cone bushing 6. Gas density sensor 18. Inner-cone cable terminal 7. Circuit breaker gas tank 19. Plug-in surge arrester 8. 3-position switch mechanism 20. Cable 9. 3-position switch 21. Rear cover 10. Main busbar and bushing 22. Pressure relief of busbar gas tank 11. Busbar gas tank 23. Earthing busbar 12. Front cover 24. Current transformer (Optional) 6 N2S OEM Functional Unit OEM Functional Unit N2S offers OEM partners the following modular functional units: No. Scheme N2S Type 1 Denomination Incoming/outgoing panel LNL LNTL 2 - Cable top entry - Cable bottom entry Sectionalizer panel LNCV-RD - Panel busbar Right Direction extensible (RD) Connected with LNCD-LD panel busbar at right side, and connected with system main busbar at left side. LNCV-LD - Panel busbar Left Direction extensible (LD) Connected with LNCD-RD panel busbar at left side, and connected with system main busbar at right side. Continued Description No. -Include one busbar gas tank and one circuit breaker gas tank. -In busbar tank, there are one 3-position switch and three groups of inner-cone bushings, two for both-side extension of the busbar and one for plugging to upper circuit breaker gas tank. -In circuit breaker tank, there are one vacuum circuit breaker and four groups of inner-cone bushings, three for plug-in cable terminal, PT and surge arrester. For example, double incoming cables and PT can be plugged from outside of the gas tank. The other group is for plugging to lower busbar gas tank. -The empty bushings will be sealed by end plugs or by white plastics covers on request. -Earthing switch can be cancelled or blocked if necessary. 4 -Include one busbar gas tank and one circuit breaker gas tank. -In busbar tank, there are one 3-position switch and two groups of inner-cone bushings, one for system main busbar extension and one for plugging to upper circuit breaker gas tank. -In circuit breaker tank, there are one vacuum circuit breaker and two groups of inner-cone bushings, one for connecting with neighbour panel busbar by plug-in type connectors and one for plugging to lower busbar gas tank. For example, LNCD-LD is a panel with busbar left side extension. -Earthing switch can be cancelled or blocked if necessary. Scheme Busbar riser panel LNCD-RD - Panel busbar Right Direction extensible(RD) Connected with LNCV-LD panel busbar at right side, and connected with system main busbar at left side. LNCD-LD - Panel busbar Left Direction extensible(LD) Connected with LNCV-RD panel busbar at left side, and connected with system main busbar at right side. -Include one busbar gas tank and one CT gas tank. -In busbar tank, there are one 3-position switch and two groups of inner-cone bushings, one for system main busbar extension and one for plugging to upper circuit breaker gas tank. -In CT tank, there are three epoxy-casted CTs and two groups of inner-cone bushings, one for connecting with neighbour panel busbar by plug-in type connector and one for plugging to lower busbar gas tank. For example, LNCDLD is a panel with busbar left side extension. -Earthing switch can be cancelled or blocked if necessary. Denomination DS riser panel LNDL - Cable top entry LNDTL - Cable bottom entry Description -Include one busbar gas tank and one busbar riser gas tank. -In busbar tank, there are one 3-position switch and two groups of inner-cone bushings, one for system main busbar extension and one for plugging to upper circuit breaker gas tank. -In busbar riser tank, there are four groups of inner-cone bushings, three for plugin cable terminal, PT and surge arrester. For example, double incoming cables and PT can be plugged from outside of the gas tank. The other group is for plugging to lower busbar gas tank. -The empty bushings will be sealed by end plugs or by white plastics covers on request. -Earthing switch can be cancelled or blocked if necessary. 5 LND-T2D PT panel -Include one busbar gas tank equipped with one 3-position switch. -In busbar tank, there are two groups of innercone bushings, one for plug-in PT and one for plug-in surge arrester. 6 LNM Metering panel -Include one busbar gas tank equipped with three epoxy-casted CTs . -In busbar tank , there are three groups of inner-cone bushings, one for plug-in PT and two for system main busbar extension. LNE Busbar earthing panel LNE-RD -Right Direction -Include one busbar gas tank -In busbar tank, there are one earthing switch disconnector and one group of inner-cone bushings, for system main busbar extension. For example, LNE-LD is system main busbar Left Direction extension. 7 3 Type extensible(RD) LNE-LD -Left Direction extensible(LD) Designation: Panels are designated as per above types plus the rated voltage in kV and rated current for feeder busbar in A. In case of the discrepancy for the rated current between the main busbar and feeder busbar, the rated current of the main busbar shall be specified in the bracket. For example: N2S-LNL-12/1250: 12kV incoming panel, the rated current for the feeder busbar is 1250A while the rated current for the main busbar is 1250A. N2S-LNL-12/1600 (2500): 12kV incoming panel, the rated current for the feeder busbar is 1600A while the rated current for the main busbar is 2500A. 7 8 N2S N2S Typical Schemes Typical Schemes Typical primary schemes-N2S Typical primary schemes-N2S 1 No . 3* 2 4* 5 Primary circuit scheme VCB VEG 1 3-position switch IST KSOH Toroidal type 1 1 6 7* b) b) b) a) a) a) Primary circuit scheme 1 VCB VEG 1 3-position switch IST 1 1 1 1 1 3 3 3 3 a) Optional 3 a) Optional 3 b) Optional 3 PT GBEA Inner-cone plug-in type Available Available Inner-cone 3EH2 plug-in type Outer-cone CJBKP plug-in type 3 3 3 3 Available Available Available Available Incoming/outgoing panel 8* No . Primary circuit scheme 9 10 11* 12* b) b) b) b) a) a) a) a) a) 13 KSOH Toroidal type a) Optional 3 a) Optional 1 3 1 a) Optional 3 a) Optional 1 3 PT GBEA Inner-cone plug-in type EFEN (within PT) Voltage indicator 9 20 19* 21 b) b) b) b) b) a) a) a) a) a) a) 1 1 a) Optional 3 a) Optional 3 a) Optional 3 a) Optional 3 a) Optional 3 a) Optional 3 b) Optional 3 b) Optional 3 b) Optional 3 b) Optional 3 b) Optional 3 b) Optional 3 3 3 Voltage indicator Available Available 14 a) Optional 3 3 Available Available Available Inner-cone 3EH2 plug-in type Outer-cone CJBKP plug-in type 1 VCB VEG 1 1 3-position switch IST 3 3 3 3 Overhead incoming/outgoing riser panel 23* 22* 1 3 Available 3 Overhead incoming/ outgoing panel No . 3 Available b) b) a) a) 24 Overhead DS riser panel 25 26 27 1 1 1 28* 1 1 1 1 KSOH Toroidal type a) Optional 3 a) Optional 3 GIS12L Post type b) Optional 3 b) Optional 3 CT GIS12L Post type Remarks 18* b) 3 EFEN (within PT) Remarks CT Surge arrester HV fuse Primary circuit scheme VCB VEG 1 PT GBEA Inner-cone plug-in type Surge arrester Cable riser panel b) 3-position switch IST Available 3 3 GIS12L Post type b) Optional 3 3 3 Remarks b) Optional 3 3 EFEN (within PT) Voltage indicator HV fuse 3 17 CT GIS12L Post type Surge arrester KSOH Toroidal type a) Optional 3 CT HV fuse 16 15* No . Inner-cone 3EH2 plug-in type Outer-cone CJBKP plug-in type b) Optional 3 b) Optional 3 b) Optional 3 b) Optional 3 b) Optional 3 3 3 3 PT GBEA Inner-cone plug-in type 3 3 3 HV fuse Available Available Available 3 Cable riser panel Available Available 3 3 DS riser panel Available Available 3 Overhead incoming/outgoing panel EFEN (within PT) Voltage indicator Surge arrester Remarks Inner-cone 3EH2 plug-in type Outer-cone CJBKP plug-in type Optional 3 Optional 3 Optional 3 Optional 3 3 3 3 3 3 3 3 Available Available Available Available 3 Overhead DS riser panel Available 3 Available 3 Sectionalizer panel Busbar riser panel Busbar coupler riser panel 10 N2S N2X Technical Specifications Typical Schemes Typical primary schemes-N2S 29 No . 31 30 32 33 34** 35** Item No. Primary circuit scheme 1 Rated voltage 2 Rated power frequency withstand voltage (1min) Between phases and to earth Rated lightning impulse withstand voltage Between phases and to earth VCB VEG 3-position switch IST 1 3 1 KSOH Toroidal type Data (IEC/GB) Unit kV Across the isolating distance Across the isolating distance 12 17.5/24 28/42 50 32/48 60 75 125 85 145 kV kV CT GIS12L Post type Optional 3 PT GBEA Inner-cone plug-in type HV fuse EFEN (within PT) Voltage indicator Surge arrester Available Inner-cone plug-in type Outer-cone CJBKP plug-in type 3EH2 Upon Request Upon Request Upon Request Upon Request 3 3 3 3 3 3 3 Available Available Available 3 3 XRNP Available 3 XRNP Voltage Voltage measuring panel measuring panel with surge arrester 37** 38** GIS metering panel 39 40 Primary circuit scheme VCB VEG 3-position switch IST ISARC1-03 ISARC1-03 Upon Request Upon Request Upon Request Upon Request Upon Request Upon Request AIS metering panel 41 3 Available HY5WS 36** No . 3 3 3 Busbar riser panel Remarks 3 42 3 4 Rated frequency Hz 50/60 5 Rated current A 630/1250 6 Making single/back to back capacitor bank current A 630/400 400/400 7 Rated short-circuit breaking current kA 25/31.5 20/25 8 Rated short-circuit making current (peak) kA 63/80 50/63 9 Rated short-time withstand current/ duration kA/s 25/3,31.5/3 20/3,25/3 10 Rated peak withstand current kA 63/80 50/63 11 Rated capacitor bank inrush making capacity kA 12 Rated cable-charging breaking current A 13 Rated operating sequences 14 Rated filling gas pressure (abs,20℃) MPa 0.12 15 Alarm pressure (abs,20℃) MPa 0.11 16 Minimum operating pressure (abs,20℃) MPa 0.10 17 Annual leakage rate %/Y <0.1 18 Degree of protection KSOH Toroidal type CT GIS12L Post type PT GBEA Inner-cone plug-in type HV fuse EFEN (within PT) Voltage indicator Surge arrester Remarks XRNP 3 Available XRNP 3 Available Inner-cone 3EH2 plug-in type Outer-cone CJBKP plug-in type XRNP 3 Available HY5WS 3 Note: * means PT can be installed with disconnector additionally; ** means the width a is 800mm; With regard to the type of all components in the schemes, the actual type in application shall prevail. 11 31.5 25 O-0.3s-CO-3min-CO High voltage live parts IP65 Low voltage compartment IP4X 19 Rated voltage of auxiliary circuit V 20 Rated power frequency withstand voltage of auxiliary circuit (1 min) kV AIS metering panel 20 DC24, 48, 110, 220 AC220 2 *Note: The insulating level is tested under 0.1 MPa or 1 bar (abs. 20℃) of insulating gas. 12 N2X N2X OEM Functional Unit Panel Structure N2X offers OEM partners the following modular functional units: No. 1 1 2 Scheme Type LNL Denomination Incoming/outgoing panel 3 12 4 13 5 Incoming/outgoing panel 6 LNL-BD 14 7 - One more spare inner-cone bushing on cable side Description -Include one gas tank Type A. -Inside gas tank, there are one 3-position switch and one vacuum circuit breaker. -Two groups of inner-cone bushings for both-side extension of the system main busbar. - One group of outer-cone bushings for T and/or elbow type cable terminal and/or elbow type surge arrester. For example, double incoming cables and surge arrester can be plugged outside of the gas tank. -Earthing switch can be cancelled or blocked if necessary. Same as Type A. And -There are one more group of inner-cone bushings on Bottom Direction(BD), means cable side for plug-in PT or surge arrester. 8 Incoming/outgoing panel LNL-TD 15 9 - One more spare inner-cone bushing on busbar side Same as Type A. And -There are one more group of inner-cone bushing on Top Direction(TD), means main busbar side for plug-in PT or surge arrester. 10 2 11 LNCV-RD LNCV-LD 1. Low voltage compartment 9. Outer-cone cable terminal 2. Protection and control unit 10. Cable compartment 3. Low voltage compartment door 11. Cable compartment door 4. Gas tank filling and pressure checking valve 5. 3-position switch operating mechanism 6. 3-position switch 7. Vacuum circuit breaker operating mechanism LNCV-RD-TD 12. Pressure relief 13. Gas tank 14. Main busbar 15. Toroidal current transformer LNCV-LD-TD Sectionalizer panel -Panel busbar Right Direction extensible(RD) Connected with LNCD-LD at panel busbar right side, and connected with system main busbar at left side. -Panel busbar Light Direction extensible(LD) Connected with LNCD-RD at panel busbar left side, and connected with system main busbar at right side. -Include one gas tank Type B. -Inside tank, there are one 3-position switch and one vacuum circuit breaker. -Two groups of inner-cone bushings, one for system main busbar extension and one for connecting with neighbour panel busbar by plug-in type connectors. For example, LNCV-LD is a panel with busbar left side extension. -Earthing switch can be cancelled or blocked if necessary. Sectionalizer panel -Panel busbar Right Direction extensible(RD) One more spare inner-cone bushing on busbar side -Panel busbar Light Direction extensible(LD) One more spare inner-cone bushing on busbar side Same as gas tank Type B. And -There are one more group of inner-cone bushings on Top Direction(TD), means main busbar side for plug-in PT or surge arrester. 8. Vacuum circuit breaker 13 14 N2X N2X OEM Functional Unit Typical Schemes Continued Typical primary schemes-N2X 1 2 3 4* 5* 6* 7* VCB VEG 1 1 1 1 1 1 1 3-position switch IST 1 1 1 1 1 1 1 3 3 3 3 3 3 3 3 3 3 3 3 3 Available Available Available No . No. 3 Type Scheme LNCD-RD LNCD-LD LNCD-RD-TD LNCD-LD-TD Denomination Description Busbar riser panel -Panel busbar Right Direction extensible(RD) Connected with LNCV-LD at panel busbar right side, and connected with system main busbar at left side. -Panel busbar Light Direction extensible(LD) Connected with LNCV-RD at panel busbar left side, and connected with system main busbar at right side. -Include one gas tank Type C . -Inside tank , there is one 3-position switch . -Two groups of inner-cone bushings, one for system main busbar extension and one for connecting with neighbour panel busbar by plug-in type connectors. For example, LNCD-LD is a panel with busbar left side extension. -Earthing switch can be cancelled or blocked if necessary. Busbar riser panel -Panel busbar Right Direction extensible(RD) One more spare inner-cone bushing on busbar side -Panel busbar Light Direction extensible(LD) One more spare inner-cone bushing on busbar side Same as gas tank Type C. And -There are one more group of inner-cone bushings on Top Direction(TD), means main busbar side for plug-in PT or surge arrester. DS riser panel -Include one gas tank . -Inside tank , there is one 3-position switch . -Two groups of inner-cone bushings for both-side extension of system main busbar. -One group of outer-cone bushings for T and/or elbow type cable terminal and/or elbow type surge arrester. For example, double incoming cables and surge arrester can be plugged from outside of the gas tank. -Earthing switch can be cancelled or blocked if necessary. Primary circuit scheme KSOH Toroidal type CT GIS12L Post type PT GBEA Inner-cone plug-in type HV fuse EFEN (within PT) Available Voltage indicator 4 5 6 LNDL LND-B2D LNM PT panel Metering panel -Include one gas tank special for PT panel. -Inside tank , there is one 3-position switch . -Four groups of inner-cone bushings, two for both-side extension of system main busbar, and two for plug-in PTs and surge arresters from Bottom Direction(B2D). -Include one gas tank equipped with three epoxy-casted CTs . -Inside tank, there are three groups of innercone bushings, one for plug-in PT and two for system main busbar extension. Surge arrester 3EH2 Available Available Available 3 3 Inner-cone plug-in type Outer-cone CJBKP plug-in type 3 3 3 Incoming/outgoing panel Remarks 8 No . Primary circuit scheme 9 10 11* 13* 12* 14* b) b) b) b) b) b) b) a) a) a) a) a) a) a) VCB VEG 3-position switch IST 7 LNE LNE-RD LNE-LD Busbar earthing panel - Main busbar Right Direction extensible(RD) - Main busbar Light Direction extensible(LD) -Include one gas tank -Inside tank, there are one earthing switch disconnector and one group of inner-cone bushings, for system main busbar extension. For example, LNE-LD is a system with main busbar left side extension. KSOH Toroidal type a) Optional 3 a) Optional 3 a) Optional 3 a) Optional 3 a) Optional 3 a) Optional 3 a) Optional 3 GIS12L Post type b) Optional 3 b) Optional 3 b) Optional 3 b) Optional 3 b) Optional 3 b) Optional 3 b) Optional 3 3 3 3 3 3 3 Available Available Available CT PT GBEA Inner-cone plug-in type HV fuse EFEN (within PT) Voltage indicator Designation: Panels are designated as per above types plus the rated voltage in kV and rated current for feeder busbar in A. In case of the discrepancy for the rated current between the main busbar and feeder busbar, the rated current of the main busbar shall be specified in the bracket. For example: N2X-LNL-12/1250: 12kV incoming panel, the rated current for the feeder busbar is 1250A while the rated current for the main busbar is 1250A. N2X-LNL-12/630 (800): 12kV incoming panel, the rated current for the feeder busbar is 630A while the rated current for the main busbar is 800A. 15 Surge arrester Remarks Inner-cone plug-in type Outer-cone CJBKP plug-in type Available Available 3EH2 Available Available 3 3 3 3 3 Cable riser panel 16 N2X N2X Typical Schemes Typical Schemes Typical primary schemes-N2X Typical primary schemes-N2X 15 No . Primary circuit scheme 16 17 18* 19* 20* No . 21* b) b) b) b) b) b) b) a) a) a) a) a) a) a) 1 1 1 1 1 1 1 3-position switch IST a) Optional 3 a) Optional 3 a) Optional 3 a) Optional 3 a) Optional 3 a) Optional 3 a) Optional 3 GIS12L Post type b) Optional 3 b) Optional 3 b) Optional 3 b) Optional 3 b) Optional 3 b) Optional 3 b) Optional 3 3 3 3 PT GBEA Inner-cone plug-in type 3 3 3 HV fuse Available Available Available EFEN (within PT) Voltage indicator Available Inner-cone 3EH2 plug-in type Outer-cone CJBKP plug-in type Available Available 3 Available 3 3 3 22 23* 24* 25 EFEN (within PT) 26* 28 27* 3 34 1 1 1 1 35 Optional 3 3 3 JDZR 2 3 JDZR 2 3 3 3 XRNP 3 3 XRNP 3 3 3 Available Available Available Inner-cone 3EH2 plug-in type Outer-cone CJBKP plug-in type Available Available 3 3 3 Voltage measuring panel (AIS) (GIS) Busbar coupler riser panel 36 No . Primary circuit scheme Optional Voltage indicator Remarks DS riser panel No . GIS12L Post type Surge arrester 3 Remarks 38** 37** Voltage measuring panel with surge arrester (AIS) (GIS) 39** 40*** 41*** AIS metering panel 42 Primary circuit scheme VCB VEG 1 1 1 3-position switch IST 1 1 1 VCB VEG 1 1 3-position switch IST 1 KSOH Toroidal type ISARC1-03 KSOH Toroidal type CT CT GIS12L Post type Optional PT GBEA Inner-cone plug-in type EFEN (within PT) 3 Optional 3 Optional 3 Optional Inner-cone plug-in type Outer-cone CJBKP plug-in type 3EH2 GIS12L Post type 3 3 3 PT GBEA Inner-cone plug-in type 3 3 HV fuse Voltage indicator Remarks 33 CT PT GBEA Inner-cone plug-in type Surge arrester 32 KSOH Toroidal type KSOH Toroidal type CT HV fuse 31 VCB VEG 3-position switch IST Surge arrester 30* Primary circuit scheme VCB VEG HV fuse 29* EFEN (within PT) Voltage indicator 3 Sectionalizer panel 3 Busbar riser panel Surge arrester Busbar coupler riser panel Remarks Inner-cone plug-in type Outer-cone CJBKP plug-in type 3EH2 3 Upon Request Upon Request Upon Request Upon Request Upon Request 3 Upon Request Upon Request Upon Request Upon Request Upon Request 3 Available XRNP Available 3 XRNP 3 Available XRNP 3 Available XRNP 3 Available XRNP 3 Available 3 HY5WS GIS metering panel 3 HY5WS 3 HY5WS 3 AIS metering panel Note: * means the depth b shall be 150mm more. PT can be installed with disconnector additionally and installation against wall is not recommended; ** means the width a is 800mm; ***means the width a is 1000mm; With regard to the type of all components in the schemes, the actual type in application shall prevail. 17 18 N2S/N2X N2S/N2X Application Schemes Foundation Frame N2S Application Schemes Foundation Frame N2S-13 N2S-13 N2S-31 N2S-24 N2S-25 N2S-31 N2S-13 N2S-13 For easy installation and proper long term function, it is recommended that N2S/N2X switchgear shall be mounted on foundation frame or profile steel which shall be laid by qualified personnel. Detailed size for foundation frame of N2S/N2X switchgear or installation hole of profile steel, please refer to the below pictures. Relevant standards are recommended to be complied when laying the foundation frame, in particular the evenness and straightness tolerances as a pre-condition for a perfect switchgear assembly. Tolerance conditions for laying the frame are: -Evenness tolerance: ±1mm/m2 -Straightness tolerance: Max.1 mm per meter, but max. 2mm for the entire length of the frame. Foundation Frame of N2S Switchgear N2S-31 N2S-24 N2S-25 Busbar Voltage measuring Overhead panel riser incoming/outgoing panel with surge arrester panel N2S-1 N2S-1 N2S-1 Overhead incoming/outgoing panel a a 800 0 M1 N2S-2 b-50 150 N2S-38 Sectionalizer panel 35 Voltage measuring Overhead panel incoming/outgoing with surge arrester panel 25 Overhead incoming/outgoing panel Busbar riser panel Incoming/ outgoing panel Incoming/ outgoing panel Incoming/ outgoing panel Incoming/ outgoing panel 50 a-50 a-50 50 750 35 N2X Application Schemes 50 220 Sectionalizer panel 525 Voltage measuring panel with surge arrester 25 AIS metering panel Frame: 10# profile steel 25 N2X-04 N2X-01 N2X-01 N2X-24 N2X-27 N2X-02 N2X-01 25 N2X-04 Foundation Frame of N2X Switchgear 35 a a 0 200 M1 800 Incoming/ outgoing panel Incoming/ outgoing panel Incoming/ outgoing panel Sectionalizer panel Busbar riser panel Incoming/ outgoing panel Incoming/ outgoing panel N2X-01 N2X-02 Incoming/ outgoing panel N2X-23 N2X-27 N2X-01 N2X-01 N2X-02 b-25 Frame: 10# profile steel N2X-41 50 AIS metering panel 19 Sectionalizer panel Busbar riser panel Incoming/ outgoing panel Incoming/ outgoing panel Incoming/ outgoing panel Incoming/ outgoing panel Incoming/ outgoing panel 35 25 50 a-50 25 a-50 50 750 25 20 N2S/N2X N2S/N2X Layout Plan Cable Layer N2S Switchgear Cable layer for N2S/N2X Switchgear Rear aisle >800 4 185 >500 a-100 Pressure relief hole 255 a a a a Sectionalizer panel Busbar riser panel a a 800 Metering panel >1200 25 800 2 60 Secondary cable hole 50×50 110 35 25 90 Secondary cable hole 55×100 Metering panel >1500 1 Side cover 300 Pressure relief hole Cable hole 380 Cable hole Side cover Height≥ 2800mm 1~3mm Front aisle 525 b-50 25 35 700 >700 >50 75 75 3 1300 5 N2X Switchgear 700 a-100 >800 25 800 a a >1500 Metering panel 21 Front aisle a Sectionalizer panel a Busbar riser panel 1.N2S/N2X switchgear a a 2.Lower ventilation 3.Cable layer 4.Upper ventilation 5.Cable layer ventilation 800 Metering panel >1200 Secondary cable hole 80×85 80 80 85 25 Side cover b-500 250 Side cover 35 b-25 35 >200 50 Height≥ 2800mm 22 N2S/N2X Notes Cable Trench Cable trench for N2S switchgear Circuit breaker mechanism Circuit breaker gas tank Disonncetor mechanism Incoming cable Disconnector and busbar gas tank Bottom plate Cable trench bridge Cover 80 1200 200 Cable trench Cable trench for N2X switchgear LV compartment Gas tank Cable compartment 5~10 Frame: 10# profile steel 80 1200 Frame: 10# profile steel 23 N2S/N2X Pre-laid profile steel