® Introducing The Air Cooled DX Split System Valent's fleet of high-outdoor air ventilators and comprehensive energy recovery units is now even more versatile with the addition of an air-cooled split refrigeration option. SCOPE • Air-cooled split system refrigeration option with factory-supplied remote condenser • Designed to process a wide range of entering air conditions; up to 100% outdoor air • May be paired with one of Valent's three integral air-to-air energy recovery options • Available in the 110, 210, and 310 casings from 5 to 40 nominal tons BENEFITS Increased Reliability Reduced Installation Costs • Valent-built remote condensing unit designed for pairing with ventilator • Only two refrigerant lines required per circuit, including circuits with hot gas reheat • Direct-drive plenum fans without belts to maintain • Multiple duct connection options simplify installation and reduce unnecessary ductwork Reduced Operating Costs • Factory installed and piped receiver to reduce field piping • Optional air-to-air energy recovery reduces cooling and dehumidification loads Reduced Sound Transmission • Refrigeration system managed by Valent's standard microprocessor controller for optimal efficiency • Compressors installed in ventilator with rubber isolators on double-wall foam-injected interior shelves to absorb vibration Improved Indoor Air Quality (IAQ) • All factory refrigeration components and lines enclosed in double-wall foam-injected casing to dampen sound transmission • Multiple supply air filter options (up to MERV 14) to remove contaminants from airstream • Integral modulating hot gas reheat system for humidity control Valent is a business of Unison® Comfort Technologies. ® THOROUGH DESIGN AND TESTING The split system refrigeration option is designed with the same dedication to quality and reliability as Valent's packaged ventilators. Features such as 2" foam-injected double-wall panels, direct-drive plenum fans, and factory provided controls are standard in support of this commitment. Valent prides itself on a thorough, 1 - 1.5 hour run test of each and every unit prior to shipment. The air cooled split system is no exception, receiving the same type of run test as our packaged equipment. What's more, the factory-run test for split systems is executed with the remote condenser ordered with the ventilator — ensuring that the pair operate together reliably prior to shipment. CAPACITIES AND AVAILABILITY The air-cooled split system option from Valent utilizes the same casing and nominal tonnage pairings as our packaged units. Airflows, capacities, and other options are summarized in the table below. Casing 110 210 310 Airflow Range Nominal Tonnages Dehumidification High Airflow Coil Indirect Gas Coil Set [cfm] Set [cfm] Heat1 [MBH] 5 8 10 10 13 16 18 20 25 25 30 35 40 650 - 1,250 1,040 - 2,000 1,300 - 2,500 1,300 - 2,500 1,690 - 3,250 2,080 - 4,000 2,340 - 4,500 2,600 - 5,000 3,250 - 6,250 3,250 - 6,250 3,900 - 7,500 4,550 - 8,750 5,200 - 10,000 1,000 - 2,250 1,600 - 3,600 N/A 2,000 - 4,500 2,600 - 5,850 3,200 - 7,200 3,600 - 8,000 4,000 - 8,000 N/A 5,000 - 11,250 6,000 - 12,000 7,000 - 12,000 N/A Heating Refrigeration Digital Scroll™ Circuits and Compressor Total Stages Hot Water 100 -200 10 - 50 YES STD 1/1 OPT AHPC 1.0 STD, AHPC 2.0 OPT OPT OPT OPT 200 - 400 15 - 125 YES STD 2/2 OPT AHPC 1.0 STD, AHPC 2.0 OPT OPT OPT OPT 400 - 800 20 - 150 YES STD 2/4 OPT AHPC 1.0 STD, AHPC 2.0 OPT OPT OPT OPT Units with indirect gas heat are ETL-listed for indoor or outdoor installations. Electric heat capacities are shown at 460/3/60 VAC. 3 "AHPC" stands for Active Head Pressure Control 2 DUCT CONNECTIONS Units with the split refrigeration option are available with a number of duct location connections for installation flexibility. End 1 2 Outdoor Air Intake Supply Air Discharge X Return Air Intake Exhaust Air Discharge X1 X Front X X2 Back X X2 Bottom X X End return air intake only available on VPR series. Front or back return air intake only available on VPRE, VPRP, and VPRC series. Contact your Valent representative today for more information. www.valentair.com 60 28TH AVENUE NORTH, SUITE 100 MINNEAPOLIS, MINNESOTA 55411 T – 612.877.4850 VLT-PA-05 12/13 Refrigeration Enthalpy Sensible Enthalpic Plate Plate Management3 Wheel Electric2 [kW] 1 Duct Location Modulating HGRH Energy Recovery