Gas Outlets/Accessories #32-22110006 Anodized aluminum bottle holder slide bracket, 4” (10.160cm) #06-135012 Stainless steel slide for mounting on wood or metal. #32-22110004 Bottle holder \without lock #32-22110007 Bottle holder w//lock used with #3222110005 multi-level bottle bracket 180 Tubing Mount #32-22110005 Anodized aluminum multi-level bottle bracket, 3’ (.914m)does not include #32-22110007 Mounting Hole 2 each. 1 3/8” Several bottle holders with lock can be used simultaneously 7/32” HOLES 20 1/2” 19mm Tubing adapter WAGD (EVAC) GRILL ASSEMBLY #32-83160005 INCLUDES: • Mounting hardware with nuts and washers ( 2 each, 8-32 x 2 in. screws) • Scavenging tubing - 19mm diameter x 96 in. length OPTIONAL • Scavenging tubing, per ft. MERCURY MEDICAL® 1 1/2” #06-135134 Adjustable Slide Bracket Assembly #32-83160006 Page 120 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Puritan-Bennett/Beacon Medical Chemetron Compatible Ohmeda Compatible Service Oxygen Nitrous Oxide Medical Air Vacuum WAGD (Evacuation) Slide N2 (D.I.S.S.) Part Number #06-121030 #06-121031 #06-121032 #06-121033 #06-121039 #06-120978 #06-121104 Service Oxygen Nitrous Oxide Medical Air Vacuum WAGD (Evacuation) Slide Part Number #06-121040 #06-121041 #06-121042 #06-121043 #06-121049 #06-120978 CHEMETRON (Compatible) QUICK-CONNECT OUTLET OHMEDA (Compatible) QUICK-CONNECT OUTLET DIAMETER INDEX SAFETY SYSTEM (D.I.S.S.) OUTLET PURITAN-BENNETT QUICK CONNECT OUTLET D.I.S.S. Service Oxygen Nitrous Oxide Medical Air Vacuum WAGD (Evacuation) Slide MERCURY MEDICAL® Service Oxygen Nitrous Oxide Medical Air Vacuum WAGD (Evacuation) Nitrogen Carbon Dioxide CO2-O2 (CO2>7.5%) O2-CO2 (CO2<7.5%) HeO2 (He>7.5%) O2-He (He<7.5%) Slide Part Number #06-121020 #06-121021 #06-121022 #06-121023 #06-121029 #06-120978 Page 121 Part Number #06-121100 #06-121101 #06-121102 #06-121103 #06-121109 #06-121104 #06-121110 #06-121111 #06-121112 #06-121113 #06-121114 #06-120978 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Accessories/Beacon Medaes/Puritan-Bennett GAUGE ELECTRICAL Accessories shall be of a modular design allowing them to be ganged with a Beacon Medical (Puritan-Bennett) manufactured medical gas outlets on the job site to create a consolelike appearance. Each accessory shall consist of a rough-in and finish assembly. All Electrical Accessories utilize UL/CSA recognized hospital grade receptacles. The rough-in for electrical devices shall include a standard electrical box for electrical connections. Gauges shall have a pressure range of 0-100 psi for Oxygen, Nitrous Oxide, Medical air, and Carbon Dioxide; 0-300 psi for Nitrogen and 0-30” Hg for Vacuum and Evacuation. Gas specificity shall be maintained by positive pin indexing between rough-in and finish assembly. A machined brass outlet block shall be permanently attached to the mounting plate in such a manner so as to permit the 7inch long, 3/8” O.D. type K copper inlet tube to be swiveled 360° for attachment to the piping system. A secondary valve shall be installed in the outlet block assembly for pressure testing and to prevent gas flow when the gauge is removed. SLIDE BLANK Slides shall be extruded aluminum mounted to a standard insert and rough-in assembly. Blanks shall consist of a standard rough-in assembly with solid anodized aluminum insert plate and chrome plated cover plate. Service Complete Assy O2 (Oxygen) #06-120980 N2O (Nitrous oxide) #06-120981 Medical Air #06-120982 Vac (Vacuum) #06-120983 N2 (Nitrogen) #06-120984 Electrical Twist Lock #06-120970 Simplex Receptacle #06-120971 Duplex Receptacle #06-120972 Hampden Gnd. Recep. #06-120974 Miscellaneous Slide #06-120978 Blank, Gas #06-120979 Blank, Electrical #06-120969 Gauge 4” ELECTRICAL ACCESSORIES 5/8” Note: Electrical Accessories furnished with 5/8” raised device cover. For wall thickness other than 5/8” customer must furnish correct size cover. 5” 10” 15” 1/2” 20” 1/4” 2 -1/2” 5-3/4” 5” 1-1/16” 4” 3” 5” 5/16” 5-3/4” A maximum of 3 units may be ganged without additional support. MERCURY MEDICAL® Page 122 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Beacon Medical/Ohmeda Compatible QUICK CONNECT TYPE FIELD GANGABLE Ohmeda (Ohio Medical) Compatible Quick Connect Medical Gas outlets shall be gas specific for the services indicated and accept only corresponding Ohmeda (Ohio Medical) Quick Connect adapters. The Outlets shall be UL listed, CSA approved, and meet NFPA 99 Standards (formally NFPA 56-F). All outlets shall be tested and cleaned for oxygen service prior to shipping. A complete outlet shall consist of a gas specific finishing assembly to be installed after walls are finished and a matching gas specific finishing assembly to be installed after walls are finished. The rough-in assembly shall be of modular design and include a gas specific 16 ga. steel mounting plate designed to permit on-site ganging of multiple outlets, in any order, on any order, on 5 inch centerline spacing. A machined brass outlet block shall be permanently attached to the mounting plate in such a manner so as to permit the 7 inch long, 3/8” O.D. type K copper inlet tube to be swiveled 360o for attachment to the piping system. A secondary valve shall be installed in the outlet block assembly for pressure testing and to prevent gas flow when the latch/valve assembly is removed for service. A 1/2” high metal flange around the outlet block seal opening shall provide a plaster barrier. Gas service identification shall be affixed to the inlet tube and the face of the mounting plate. A temporary, transparent cover shall be provided to keep debris out of the outlet during installation while permitting labels to be viewed for outlet service identity. The latch/valve assembly shall include a double seal primary valve and be gas specific for the labeled service and accept only corresponding Ohmeda (Ohio Medical) Compatible hose and apparatus adapters. The latch/valve assembly shall be indexed to the corresponding rough-in assembly to avoid accidental cross-fitting and shall telescope up to 3/4” to allow for variation in finished wall thickness from 1/2” to 1-1/4”. A metal trim plate with permanent, color coded marking of service identification shall be included as part of the latch/valve assembly. A die cast, chrome plated coverplate shall be provided to trim each outlet and to fill the space between adjacent outlets. Coverplate design shall allow latch valves to be individually removed for servicing. OHMEDA • UL Listed/CSA Approved • Meets or exceeds National and International Codes • Compensates For Variation In Wall Thickness Up To 3/4” • 360o Swivel Inlet Tube To Simplify Installation • Gas Specific Indexing • Modular Design For Simplified On-Site Arrangement • Accepts All Corresponding Ohmeda Gas Specific Compatible Adapters • Made In the U.S.A. MERCURY MEDICAL® Item Number Service #06-121030 #06-121031 #06-121032 #06-121033 #06-121039 #06-120978 #06-121104 O2 OHMEDA Q.C. N 2O MEDICAL AIR VAC WAGD (EVACUATION) SLIDE N2 (D.I.S.S.) Page 123 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Allied Healthcare The Puritan-Bennett Style Outlet: Easy-to-Use and Reliable. • Fingertip, push-button release mechanism for secondary equipment. • Utilizes Chemetron backbox for easy upgrade to Chemetron Completion Kit. • Die-cast faceplate is chrome-plated for long life and durability. • Non-interchangeable indexing system, prevents mislabeling. Domestic ISO PB STYLE QUICK CONNECT QUICK CONNECT Oxygen Vacuum Medical Air Nitrous Oxide WAGD (Evacuation) Carbon Dioxide O2/CO2<7% #32-64-03-5001 #32-64-03-5002 #32-64-03-5003 #32-64-03-5004 #32-64-03-5006 #32-64-03-5007 #32-64-03-5008 #32-64-03-5051 #32-64-03-5052 #32-64-03-5053 #32-64-03-5004 #32-64-03-5006 #32-64-03-5007 #32-64-03-5008 • Meets NFPA and CGA standards. • Cleaned and tested for oxygen use. The Oxequip Outlet: Flexibility that meets all the Standards. • Outlet design meets Domestic and International standards for medical gas equipment. • Modular design gives installer flexibility to vary sequence of gases for individual rooms. • Color-coded outlet has non-interchangeable indexing system to prevent accidental interchange. • Improved secondary check increases gas flow to patients. • Easier installation due to adjustability for varying wall thickness and adjustable rotating inlet tube. • U.L. and C.S.A. approved. DOMESTIC ISO OXEQUIP Oxygen Vacuum Medical Air Nitrous Oxide WAGD (Evacuation) Carbon Dioxide Quick Connect #21-1930-2112 #21-1930-2212 #21-1930-2412 #21-1930-2312 #21-1930-2712 #21-1930-2512 Quick Connect #21-1930-2121 #21-1930-2221 #21-1930-2421 #21-1930-2321 #21-1930-2721 #21-1930-2521 Oxygen Vacuum Medical Air Nitrous Oxide WAGD (Evacuation) Carbon Dioxide D.I.S.S. #21-1930-1112 #21-1930-1212 #21-1930-1412 #21-1930-1312 #21-1930-1712 #21-1930-1512 D.I.S.S. #21-1930-1121 #21-1930-1221 #21-1930-1421 #21-1930-1321 #21-1930-1721 #21-1930-1521 • Chrome-plated, die-cast faceplate provides durability and improved appearance. MERCURY MEDICAL® Page 124 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Chemetron/(NCG) SURFACE MOUNTED QUICK-CONNECT WALL STATION (top inlet, 3 5/8” (9.21 cm) centers) 349 Series #32-64-12-0001 #32-64-12-0002 #32-64-12-0003 #32-64-12-0004 #32-64-12-0005 #32-64-12-0006 #32-64-12-0009 #32-64-12-0011 #32-64-12-0013 #32-64-12-0016 #32-64-12-0018 #32-64-15-0001 #32-64-15-0002 #32-64-15-0004 #32-64-15-0005 #32-64-15-0006 #32-64-15-0007 #32-64-15-0008 #32-64-15-0010 Oxygen Medical Air Vacuum Nitrous Oxide Oxygen-Blank-Medical Air Oxygen-Blank-Vacuum Oxygen-Blank-Nitrous Oxide Nitrogen Oxygen-Blank-Oxygen Vacuum-Blank-Oxygen Vacuum-Blank-Vacuum SURFACE MOUNTED D.I.S.S. WALL STATION (top inlet, 3 5/8” (9.21 cm) centers) 347 Series Oxygen Medical Air Oxygen-Blank-Medical Air Oxygen-Blank-Vacuum Oxygen-Blank-Nitrous Oxide Vacuum Nitrous Oxide Vacuum-Blank-Vacuum WALL (FLUSH) QUICK-CONNECT OUTLET STATION 500 Series (Field Gangable) 400 Series Top Inlet 400 Series Bottom Inlet #32-64-01-5001 Oxygen #32-64-20-0001 Oxygen #32-64-26-0001 #32-64-01-5002 Vacuum #32-64-20-0002 Medical Air #32-64-26-0002 #32-64-01-5003 Medical Air #32-64-20-0004 Carbon Dioxide #32-64-01-5004 Nitrous Oxide #32-64-20-0005 Vacuum #32-64-26-0005 #32-64-01-5006 WAGD (Evacuation) #32-64-20-0006 Nitrous Oxide #32-64-01-5007 Carbon Dioxide #32-64-20-0003 95%O2, 5% #32-64-01-5008 95%, 02, 5%, CO2 CO2 #32-64-01-9431 Blank fascia cover kit #32-64-20-0008 WAGD (Evacuation) #32-64-06-0001 Vacuum bottle slide Assy WALL /CEILING (FLUSH) D.I.S.S. OUTLET STATION 560 Series (Field Gangable) 460 Series #32-64-04-5601 Oxygen #32-64-04-5602 Vacuum #32-64-04-5603 Medical Air #32-64-35-0001 #32-64-04-5604 Nitrous Oxide #32-64-35-0002 #32-64-04-5605 Nitrogen #32-64-35-0003 #32-64-04-5606 WAGD (Evacuation) #32-64-35-0004 #32-64-04-5607 Carbon Dioxide #32-64-35-0005 #32-64-04-5608 95% O2, 5% CO2 #32-64-06-0001 Vacuum bottle slide Assy #32-64-01-9431 Blank fascia cover kit HIGH PRESSURE NITROGEN QUICK CONNECT OUTLET #32-64-20-0007 Nitrogen HP (top inlet) DYNACON TYPE MERCURY MEDICAL® Page 125 Oxygen Medical Air Carbon Dioxide (>7%) Vacuum Nitrous Oxide STATION (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Dual Adapters INTRODUCING THE CONNECT2® MEDICAL GAS OUTLET STATION • The first medical gas outlet that accepts both Chemetron and Ohmeda adapters (patent pending design). W E N ONE OUTLET TWO ADAPTERS • Push button mechanism for quick adapter release. Ohmeda adapter has second method of release with twisted feature. q • Chemetron adapter can support secondary equipment, including a suction regulator with 1/2 gallon collection bottle. • Eliminates need for hospital personnel to carry both styles of adapters to ensure proper connection. q • Fail-safe color coding and safety keyed to ensure appropriate gas. • Valve body O-ring easily accessible for maintenance. Inlet tube has secondary check unit to permit removal of valve body without shutting off gas to the outlet. Ideal for institutions with more than one type of quick connect. Great for emergency departments receiving transported patients with ancillary gas services. • U.L. approved. The Right Connection For New Or Existing Structures 3/8” flared connection Faceplate is safety keyed to backplate Stainless steel Chemetron Push-button release Adapter Ohmeda Adapter Keying for Chemetron Adapter Keying for Ohmeda Adapter Inlet tube capable of rotating 360o Adjustment for various wall thicknesses Chrome plated Faceplate CONNECT2 5 1/4” Width Oxygen Vacuum Medical Air Nitrous Oxide WAGD (Evacuation) Carbon Dioxide O2/CO2<7% Wall Slide #32-64-02-5001 #32-64-02-5002 #32-64-02-5003 #32-64-02-5004 #32-64-02-5006 #32-64-02-5007 #32-64-02-5008 #32-64-06-0001 FASCIA ASSEMBLIES CONVERT EXISTING Chemetron 500 SERIES OR 560 SERIES OUTLETS TO DUAL CAPABILITY Oxygen Vacuum Medical Air Nitrous Oxide 2 1/4” Width Gas Outlet Oxygen Vacuum Medical air Nitrous Oxide (WAGD) Evacuation Carbon Dioxide MERCURY MEDICAL® #32-64-02-4011 #32-64-02-4012 #32-64-02-4014 #32-64-02-4013 #32-64-02-4018 #32-64-02-4015 Fascia #32-64-90-4011 #32-64-90-4012 #32-64-90-4014 #32-64-90-4013 #32-64-90-4018 #32-64-90-4015 Page 126 #32-64-02-9531 #32-64-02-9532 #32-64-02-9534 #32-64-02-9533 2 3/4” Width Outlet #32-64-02-4001 #32-64-02-4002 #32-64-02-4004 #32-64-02-4003 #32-64-02-4008 #32-64-02-4005 (800) 835-MMED n (727) 573-0088 Fascia #32-64-90-4001 #32-64-90-4002 #32-64-90-4004 #32-64-90-4003 #32-64-90-4008 #32-64-90-4005 n FAX (800) 990-6375 Gas Outlets/Genstar Tech (continued on next page) FEATURES: • Accepts only Chemetron gas specific adapters • Indexed to prevent interchangeability of gas services • Universal rough-in accepts quick connection (Chemetron®, Ohmeda®, Puritan-Bennett®) or DISS latch valve assemblies • Modular design capability • 100% hydrostatically tested • Complies with NFPA 99 and CGA G-4.1 standards • UL Listed FEATURES: • Accepts only Ohmeda gas specific adapters • Indexed to prevent interchangeability of gas services • Universal rough-in accepts quick connection (Chemetron®, Ohmeda®, Puritan-Bennett®) or DISS latch valve assemblies • Modular design capability • 100% hydrostatically tested • Complies with NFPA 99 and CGA G-4.1 standards • UL Listed SPECIFICATIONS: Medical gas outlet(s) shall be manufactured by Genstar Technologies Co., Inc. (GENTEC®). Wall outlet shall be designed for concealed piping installation and available for services indicated. SPECIFICATIONS: Medical gas outlet(s) shall be manufactured by Genstar Technologies Co., Inc. (GENTEC®). Wall outlet shall be designed for concealed piping installation and available for services indicated. The latch valve assembly shall be Chemetron quick connect compatible and accept only gas specific Chemetron type quick connect adapters. Each latch valve assembly shall be colorcoded for ease of gas identification per the appropriate standards (US or ISO). Latch valve assemblies shall have gas specific pin indexing corresponding to the rough-in assembly to prevent interchangeability of gas services and shall adjust up to 1” for variations in wall thickness. The latch valve assembly shall be Ohmeda quick connect compatible and accept only gas specific Ohmeda type quick connect adapters. Each latch valve assembly shall be colorcoded for ease of gas identification per the appropriate standards (US or ISO). Latch valve assemblies shall have gas specific pin indexing corresponding to the rough-in assembly to prevent interchangeability of gas services and shall adjust up to 1” for variations in wall thickness. Universal rough-in assembly shall include the wall rough-in plate (16 ga.) with inlet tubing silver brazed to the outlet body. Inlet tubing shall be type “K” copper, 1/2” (12.7 mm) OD, extend 6-1/2 inches (165 mm), and swivel 360° for ease of installation. Rough-in assembly shall accept only the specified gas service by use of indexes. Rough-in assembly shall be of modular design to permit on-site ganging of multiple outlets with assurance of accurate alignment and providing 5” centerline spacing. A dust plug and cover shall be provided to protect rough-in assembly from contamination during handling and installation at the job site. Universal rough-in assembly shall include the wall rough-in plate (16 ga.) with inlet tubing silver brazed to the outlet body. Inlet tubing shall be type “K” copper, 1/2” (12.7 mm) OD, extend 6-1/2 inches (165 mm), and swivel 360° for ease of installation. Rough-in assembly shall accept only the specified gas service by use of indexes. Rough-in assembly shall be of modular design to permit on-site ganging of multiple outlets with assurance of accurate alignment and providing 5” centerline spacing. A dust plug and cover shall be provided to protect rough-in assembly from contamination during handling and installation at the job site. Rough-in assemblies shall accept any latch valve assembly of the same gas service. The latch valve assembly shall be interchangeable, allowing conversion from one connection style to another without shutting down the medical gas system. Rough-in assemblies shall accept any latch valve assembly of the same gas service. The latch valve assembly shall be interchangeable, allowing conversion from one connection style to another without shutting down the medical gas system. All positive pressure gas outlets shall have a primary and secondary check valve, where the secondary valve in the rough-in assembly allows servicing of the latch valve assembly without having to disrupt gas service to the outlet. All positive pressure gas outlets shall have a primary and secondary check valve, where the secondary valve in the rough-in assembly allows servicing of the latch valve assembly without having to disrupt gas service to the outlet. Complete outlet shall be delivered to the customer in a gas specific rough-in assembly, a matching gas specific latch valve assembly, both cleaned for oxygen use and in a sealed package, and a trim plate. All assemblies shall be 100% tested for leaks, manufactured to comply with the latest edition of NFPA 99, and UL Listed. Complete outlet shall be delivered to the customer in a gas specific rough-in assembly, a matching gas specific latch valve assembly, both cleaned for oxygen use and in a sealed package, and a trim plate. All assemblies shall be 100% tested for leaks, manufactured to comply with the latest edition of NFPA 99, and UL Listed. MERCURY MEDICAL® Page 127 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Genstar Tech (continued from previous page) DIMENSIONS: (Chemetron) Dimensional Data Notes: A. Additional support needed if ganging more than 3 outlets B. Wall thickness may vary from 1/2” to 1” (12.7mm to 25.4mm). C. 1/2” O.D. (3/8” Nominal) type K copper inlet tube allows 360° swivel on outlet body for entry from any angle. D. Inch (mm) ORDERING INFORMATION CHEMETRON COMPATIBLE Gas Service Item # Oxygen #ES-3823U-O Vacuum #ES-3823U-V Medical Air #ES-3823U-A Nitrous Oxide #ES-3823E-2 WAGD #ES-3823U-W Slide #ES-3820-SLD MATERIAL Latch Valve Aluminum ABS Plastic Steel/Brass + Plating Stainless Steel Brass Neoprene Rubber Trim Plate Cast Aluminum Powder Coating Rough-in Stainless Steel ABS Plastic Neoprene Steel + Plating Copper Ordering Information for Complete Wall Outlets (Includes Latch Valve Assembly, Trim Plate and Rough-in Assembly) Note: US colors listed. For ISO 32 colors replace “U” with “E” in the above catalog numbers. DIMENSIONS: (Ohmeda) Dimensional Data Notes: A. Additional support needed if ganging more than 3 outlets B. Wall thickness may vary from 1/2” to 1” (12.7mm to 25.4mm). C. 1/2” O.D. (3/8” Nominal) type K copper inlet tube allows 360° swivel on outlet body for entry from any angle. D. Inch (mm) ORDERING INFORMATION OHMEDA COMPATIBLE Gas Service Item # Oxygen #ES-3821U-O Vacuum #ES-3821U-V Medical Air #ES-3821U-A Nitrous Oxide #ES-3821E-2 WAGD #ES-3821U-W Slide #ES-3820-SLD MATERIAL Latch Valve Aluminum ABS Plastic Steel/Brass + Plating Stainless Steel Brass Neoprene Rubber Trim Plate Cast Aluminum Powder Coating Rough-in Stainless Steel ABS Plastic Neoprene Steel + Plating Copper Ordering Information for Complete Wall Outlets (Includes Rough-in, Trim Plate and Latch Valve Assembly) Note: US colors listed. For ISO 32 colors replace “U” with “E” in the above catalog numbers. MERCURY MEDICAL® Page 128 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Genstar Tech (continued on next page) American Medical Gas Outlets Gentec Medical Gas Outlets shall be UL Listed, cleaned for medical gas service, and compliant to the latest edition of NFPA 99. They shall accept only corresponding Ohmeda®, DISS, Chemetron®, or Puritan Bennett® style quick connect adapters. Outlets are designed with an universal rough-in assembly for interchangeability on different quick connects without removing the entire outlet. For outlets providing positive pressure gas, they shall have a primary and secondary check valve, where the secondary check valve allows for servicing without isolating an entire zone. Latch Valve Assembly + Rough-In Assembly = Complete Assembly Rough-In Assembly (back) The rough-in assembly shall be manufactured using (1/2" O.D.) type “K” copper tubing, silver-brazed to the outlet body. The tubing allows 360 degrees swivel on the outlet body for easy installation. Rough-in assembly is manufactured to accept only the specified gas service by use of indexes. Features • • • • • Latch Valve Assembly (front) The latch-valve assembly shall have gas specific index corresponding to the gas service on the rough-in assembly to prevent interchanging of gas service. Each latch-valve assembly shall be color coded for it’s specified gas service. • • • FEATURES: FEATURES: • • • • • • • • Accepts only DISS gas specific adapters Indexed to prevent interchangeability of gas services Universal rough-in accepts quick connection (Chemetron®, Ohmeda®, Puritan-Bennett®) or DISS latch valve assemblies Modular design capability 100% hydrostatically tested Complies with NFPA 99 and CGA G-4.1 standards UL Listed • • • • • • Accepts only Ohmeda®, DISS, Chemetron®, or Puritan Bennett® style gas specific adapters Unique pin index for gases to prevent interchanging of gas service Universal rough-in assembly Color-coded for easy gas identification 360° swivel on the inlet pipe for easy installation UL listed and complies to the latest edition of NFPA 99 Type K, 3/8" size copper tubing [1/2" real O.D. (12.7mm)] 100% hydrostatically tested Accepts only Puritan-Bennett gas specific adapters Indexed to prevent interchangeability of gas services Universal rough-in accepts quick connection (Chemetron®, Ohmeda®, Puritan-Bennett®) or DISS latch valve assemblies Modular design capability 100% hydrostatically tested Complies with NFPA 99 and CGA G-4.1 standards UL Listed SPECIFICATIONS: SPECIFICATIONS: The latch valve assembly shall be Compressed Gas Association (CGA) Diameter Index Safety System (DISS) threaded connectors and accept only corresponding gas specific type nut and nipple adapters. Each latch valve assembly shall be color-coded for ease of gas identification per the appropriate standards (US or ISO). Latch valve assemblies shall have gas specific pin indexing corresponding to the rough-in assembly to prevent interchangeability of gas services and shall adjust up to 1” for variations in wall thickness. The latch valve assembly shall be Puritan-Bennett quick connect compatible and accept only gas specific Puritan-Bennett type quick connect adapters. Each latch valve assembly shall be color-coded for ease of gas identification per the appropriate standards (US or ISO). Latch valve assemblies shall have gas specific pin indexing corresponding to the rough-in assembly to prevent interchangeability of gas services and shall adjust up to 1” for variations in wall thickness. Universal rough-in assembly shall include the wall rough-in plate (16 ga.) with inlet tubing silver brazed to the outlet body. Inlet tubing shall be type “K” copper, 1/2” (12.7 mm) OD, extend 6-1/2 inches (165 mm), and swivel 360° for ease of installation. Rough-in assembly shall accept only the specified gas service by use of indexes. Rough-in assembly shall be of modular design to permit on-site ganging of multiple outlets with assurance of accurate alignment and providing 5” centerline spacing. A dust plug and cover shall be provided to protect roughin assembly from contamination during handling and installation at the job site. Universal rough-in assembly shall include the wall rough-in plate (16 ga.) with inlet tubing silver brazed to the outlet body. Inlet tubing shall be type “K” copper, 1/2” (12.7 mm) OD, extend 6-1/2 inches (165 mm), and swivel 360° for ease of installation. Rough-in assembly shall accept only the specified gas service by use of indexes. Rough-in assembly shall be of modular design to permit on-site ganging of multiple outlets with assurance of accurate alignment and providing 5” centerline spacing. A dust plug and cover shall be provided to protect roughin assembly from contamination during handling and installation at the job site. Rough-in assemblies shall accept any latch valve assembly of the same gas service. The latch valve assembly shall be interchangeable, allowing conversion from one connection style to another without shutting down the medical gas piping system. Rough-in assemblies shall accept any latch valve assembly of the same gas service. The latch valve assembly shall be interchangeable, allowing conversion from one connection style to another without shutting down the medical gas system. All positive pressure gas outlets shall have a primary and secondary check valve, where the secondary valve in the rough-in assembly allows servicing of the latch valve assembly without having to disrupt gas service to the outlet. All positive pressure gas outlets shall have a primary and secondary check valve, where the secondary valve in the rough-in assembly allows servicing of the latch valve assembly without having to disrupt gas service to the outlet. Complete outlet shall be delivered to the customer in a gas specific rough-in assembly, a matching gas specific latch valve assembly, both cleaned for oxygen use and in a sealed package, and a trim plate. All assemblies shall be 100% tested for leaks, manufactured to comply with the latest edition of NFPA 99, and UL Listed. Complete outlet shall be delivered to the customer in a gas specific rough-in assembly, a matching gas specific latch valve assembly, both cleaned for oxygen use and in a sealed package, and a trim plate. All assemblies shall be 100% tested for leaks, manufactured to comply with the latest edition of NFPA 99, and UL Listed. Medical gas outlet(s) shall be manufactured by Genstar Technologies Co., Inc. (GENTEC®). Wall outlet shall be designed for concealed piping installation and available for services indicated. MERCURY MEDICAL® Page 129 Medical gas outlet(s) shall be manufactured by Genstar Technologies Co., Inc. (GENTEC®). Wall outlet shall be designed for concealed piping installation and available for services indicated. (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Genstar Tech (continued from previous page) DIMENSIONS: (DISS) Dimensional Data Notes: A. Additional support needed if ganging more than 3 outlets B. Wall thickness may vary from 1/2” to 1” (12.7mm to 25.4mm). C. 1/2” O.D. (3/8” Nominal) type K copper inlet tube allows 360° swivel on outlet body for entry from any angle. D. Inch (mm) ORDERING INFORMATION DISS STANDARD Gas Service Item # Oxygen #ES-3822U-O Vacuum #ES-3822U-V Medical Air #ES-3822U-A Nitrous Oxide #ES-3822E-2 WAGD #ES-3822U-W Carbon Dioxide #ES-3822E-C Nitrogen #ES-3822E-N Slide #ES-3820-SLD MATERIAL Latch Valve Aluminum ABS Plastic Steel/Brass + Plating Stainless Steel Brass Neoprene Rubber Trim Plate Cast Aluminum Powder Coating Rough-in Stainless Steel ABS Plastic Neoprene Steel + Plating Copper Ordering Information for Complete Wall Outlets (Includes Rough-in, Trim Plate and Latch Valve Assembly) Note: US colors listed. For ISO 32 colors replace “U” with “E” in the above catalog numbers. DIMENSIONS: (Puritan-Bennett) Dimensional Data Notes: A. Additional support needed if ganging more than 3 outlets B. Wall thickness may vary from 1/2” to 1” (12.7mm to 25.4mm). C. 1/2” O.D. (3/8” Nominal) type K copper inlet tube allows 360° swivel on outlet body for entry from any angle. D. Inch (mm) ORDERING INFORMATION PURITAN-BENNETT COMPATIBLE Gas Service Item # Oxygen #ES-3824U-O Vacuum #ES-3824U-V Medical Air #ES-3824U-A Nitrous Oxide #ES-3824E-2 WAGD #ES-3824U-W Slide #ES-3820-SLD MATERIAL Latch Valve Aluminum Zinc Alloy ABS Plastic Steel + Plating Stainless Steel Brass Neoprene Rubber Trim Plate Cast Aluminum Powder Coating Rough-in Stainless Steel ABS Plastic Neoprene Steel + Plating Copper Ordering Information for Complete Wall Outlets (Includes Rough-in, Trim Plate and Latch Valve Assembly) Note: US colors listed. For ISO 32 colors replace “U” with “E” in the above catalog numbers. MERCURY MEDICAL® Page 130 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Oxequip Oxequip® Med*Star® Quick-Connect Medical Gas Outlets Elements • Safety keyed to prevent cross-connections • Conforms to NFPA 99 and CSA standards • Accepts Med*Star and ‘07 Series Adapters • Modular design • Cleaned for oxygen service • UL Listed Description The Oxequip® Med*Star® Series outlet stations provide convenient access to medical gases in patient care locations. They are fully compatible with Med*Star and ’07 Series adapters. The outlets can be grouped together in any order desired by the facility. Outlets are spaced 5" (12.7 cm) center to center. Outlet finish plates and rough-in plates are pin indexed using steel pins for positive cross-connection prevention. Valve bodies are separate from the finish plate, allowing easy testing for leaks and cross connection, and contain a self-sealing poppet. Valve bodies are field adjustable to compensate for variations in plaster thickness of 12.7 mm (1/2") to 19 mm (3/4"). The 152.5 mm (6") Type K copper inlet tube has a 9.5 mm (3/8") ID (12.7 mm (1/2") OD) connection, and can rotate 360 degrees to accommodate any field piping arrangement. The primary gas check can be serviced without shutting off the gas supply. The cam plate contains a positive latching mechanism to retain the adapter in the outlet. The adapter is removed by operating the release mechanism which is integral to the Med*Star adapter (’07 Series adapters use the twist mechanism). All components (cam plate, tumbler, valve body, poppet, faceplate) are individually field replaceable. The outlet stations are fully compliant with NFPA 99 (2002) and CSA Z-305, and are cleaned for oxygen service in accordance with CGA G-4.1. The outlet is UL listed. Rough-in plates for the outlets are zinc plated steel for corrosion resistance and fire safety. Finish plates are die-cast zinc, chrome-plated with brushed stainless inserts for appearance. Gas identification is provided by a polycarbonate plastic insert, color-coded by gas service. The cam plate/tumbler assembly is color-coded and labeled for the gas service. Release is easily accomplished with one hand using the adapter release mechanism. The primary valve poppet provides a dust proof seal. Vacuum outlets may be used with or without slide brackets for vacuum collection bottles of up to 2 liters (1/2 gallon) capacity (where slides are used, provide one per vacuum outlet). Dimensional Data Ordering Information Gas Service Item # Oxygen Vacuum Air Nitrous Oxide WAGD Carbon Dioxide Slide Bracket MERCURY MEDICAL® Page 131 (US Color Codes) #21-1930-2111 #21-1930-2211 #21-1930-2411 #21-1930-2311 #21-1930-2811 #21-1930-2511 #21-1857-A (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Oxequip Oxequip® Med*Star® DISS Medical Gas Outlets Elements • Safety keyed to prevent cross-connections • Conforms to NFPA 99 and CSA standards • Modular design • Cleaned for oxygen service • UL Listed Description The Oxequip Diameter Index Safety System (DISS) Series outlet stations provide convenient access to medical gases in patient care locations. They are fully compatible with DISS style diameter indexed threaded adapters. The outlets can be grouped together in any order desired by the facility. Outlets are spaced 5" (12.7 cm) center to center. Outlet finish plates and rough-in plates are pin indexed using steel pins for positive cross-connection prevention. The chrome-plated brass valve bodies contain a self-sealing poppet, and are separate from the finish plate, allowing easy testing for leaks and cross connection. Valve bodies are field adjustable to compensate for variations in plaster thickness of 12.7 mm (1/2") to 19 mm (3/4"). The 152.5 mm (6") Type K copper inlet tube has a 9.5 mm (3/8") ID (12.7 mm (1/2") OD) connection, and can rotate 360 degrees to accommodate any field piping arrangement. The primary gas check can be serviced without shutting off the gas supply. The outlet stations are fully compliant with NFPA 99 (2002) and CSA Z-305, and are cleaned for oxygen service in accordance with CGA G-4.1. The outlet is UL listed. Rough-in plates for the outlets are zinc plated steel for corrosion resistance and fire safety. Finish plates are die-cast zinc, chrome-plated with brushed stainless inserts for appearance. Gas identification is provided by a polycarbonate plastic insert, color-coded by gas service. Vacuum outlets may be used with or without slide brackets for vacuum collection bottles of up to 2 liters (1/2 gallon) capacity (where slides are used, provide one per vacuum outlet). Dimensional Data Ordering Information Gas Service Item # Oxygen Vacuum Air Nitrous Oxide WAGD Carbon Dioxide Nitrogen Slide Bracket MERCURY MEDICAL® Page 132 (US Color Codes) #21-1930-1111 #21-1930-1211 #21-1930-1411 #21-1930-1311 #21-1930-1811 #21-1930-1511 #21-1930-1611 #21-1857-A (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Schrader Flush Mounted “Twist Sleeve” Wall Outlets #35-040000300 Single wall outlet for oxygen #35-040000200 Single wall outlet for nitrous oxide #35-040000400 Single wall outlet for vacuum #35-040000100 Single wall outlet for medical air MERCURY MEDICAL® Page 133 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Tri-Tech QUICK-CONNECT (OHMEDA COMPATIBLE) #GP-Q1132 #GP-Q1124 #GP-Q1122 #GP-Q1116 #GP-Q1104 WAGD (evacuation) recessed outlet Oxygen recessed outlet Vacuum recessed outlet Medical air recessed outlet Nitrous Oxide recessed outlet #GP-Q2132 #GP-Q2124 #GP-Q2122 #GP-Q2116 #GP-Q2104 WAGD (evacuation) exposed outlet Oxygen exposed outlet Vacuum exposed outlet Medical air exposed outlet Nitrous Oxide exposed outlet D.I.S.S. WALL OUTLETS MERCURY MEDICAL® #GP-F1132 #GP-F1124A #GP-F1122 #GP-F1116 #GP-F1112 #GP-F1104 WAGD (evacuation) recessed outlet Oxygen recessed outlet Vacuum recessed outlet Medical air recessed outlet Nitrogen recessed outlet Nitrous Oxide recessed outlet #GP-F2132 #GP-F2124A #GP-F2122 #GP-F2116 #GP-F2112 #GP-F2104 WAGD (evacuation) exposed outlet Oxygen exposed outlet Vacuum exposed outlet Medical air exposed outlet Nitrogen exposed outlet Nitrous Oxide exposed outlet #GP-F1144 Slide Bracket for recessed outlets Page 134 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/AMICO CHEMETRON COMPATIBLE WALL OUTLETS OXYGEN MEDICAL AIR VACUUM NITROUS OXIDE WAGD (EVACUATION) VAC. SLIDE OHMEDA COMPATIBLE PURITAN-BENNETT COMPATIBLE MERCURY MEDICAL® OXYGEN MEDICAL AIR VACUUM NITROUS OXIDE NITROGEN CARBON DIOXIDE WAGD (EVACUATION) INSTRUMENT AIR VAC. SLIDE N/A N/A N/A N/A N/A N/A CEILING OUTLETS N/A N/A N/A N/A N/A N/A AM-OPBWALU-OXY AM-OPBWALU-AIR AM-OPBWALU-VAC AM-OPBWALU-N2O AM-OPBWALU-EVA AM-OWALSLIDE WALL OUTLETS D.I.S.S. DIAMETER INDEX SATY SYSTEM CEILING OUTLETS AM-OQDWALU-OXY AM-OQDWALU-AIR AM-OQDWALU-VAC AM-OQDWALU-N2O AM-OQDWALU-EVA AM-OWALSLIDE WALL OUTLETS OXYGEN MEDICAL AIR VACUUM NITROUS OXIDE WAGD (EVACUATION) VAC. SLIDE N/A N/A N/A N/A N/A N/A AM-OCHWALU-OXY AM-OCHWALU-AIR AM-OCHWALU-VAC AM-OCHWALU-N2O AM-OCHWALU-EVA AM-OWALSLIDE WALL OUTLETS OXYGEN MEDICAL AIR VACUUM NITROUS OXIDE WAGD (EVACUATION) VAC. SLIDE CEILING OUTLETS AM-ODISWALU-OXY AM-ODISWALU-AIR AM-ODISWALU-VAC AM-ODISWALU-N2O AM-ODISWALU-NIT AM-ODISWALU-CO2 AM-ODISWALU-EVA AM-ODISWALU-INA AM-OWALSLIDE Page 135 CEILING OUTLETS AM-ODISCELU-OXY AM-ODISCELU-AIR AM-ODISCELU-VAC AM-ODISCELU-N2O AM-ODISCELU-NIT AM-ODISCELU-CO2 AM-ODISCELU-EVA (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Beacon Medaes/Breakdowns/Diamond I Series Keying Disc (Item #15) is held in place by 2 screws. 1. 20. 2. 3. 19. 4. 18. 17. 1. 5. 16. 6. 15. 7. 14. 13. 8. Description 1. Box 2. Spring Clip 3. Primary Check Spring (10 Pkg) 4. Inlet Screen 5. Secondary Ball Check 6. Secondary Check Spring (10 Pkg) 7. Secondary Check O-ring (10 Pkg) 8. O-ring (10 Pkg) 9. Retainer; Vacuum Pressure Gases 10. Quad Ring (10 Pkg) 11. Locking Spring 12. Primary Check O-ring (10 Pkg) 13. Piston 14. Screw 15. Keying Disc with Ears Oxygen Nitrous Oxide Vacuum Medical air (Black) Medical air (Yellow) Evacuation Carbon Dioxide MERCURY MEDICAL® 12. 9. Item Number #98-408-1463-300 #98-203-5081-304 #98-203-4042-300 #98-203-3219-870 #98-214-7162-300 #98-409-1697-300 #98-203-3230-300 #98-203-3215-870 #98-210-0629-300 #98-210-0492-870 #98-210-0703-300 #98-210-0497-870 #98-221-2440-500 #98-221-2524-500 #98-210-4512-300 #98-210-4513-870 #98-203-5064-300 #98-210-0572-300 #98-210-0489-870 #98-6803-7030-030 #98-1406-6113-105 #98-221-2400-100 #98-221-2401-100 #98-221-2402-100 #98-221-2403-100 #98-221-2422-100 #98-221-2404-600 #98-397-0000-804 10. 11. Keying Disc Without Ears Oxygen #98-221-2405-100 Nitrous Oxide #98-221-2406-100 Vacuum #98-221-2407-100 Medical air (Yellow) #98-221-2421-100 Medical air (Black) #98-221-2408-100 WAGD (Evacuation) #98-221-2409-600 Carbon Dioxide #98-397-0000-803 16. Screw, Keying Disc #98-0140-6224-106 17. Name Plate Label Oxygen #98-205-4610-300 Nitrous Oxide #98-205-4611-300 Vacuum #98-205-4612-300 Medical air (Black) #98-205-4613-300 Medical air (Yellow) #98-205-4614-300 18. Screw, Name Plate #98-142-2243-210 19. Name Plate #98-221-2515-542 20. Primary Check Body New Style; for use with Plastic Keying Disc #98-221-2420-500 Old Style; For use with metal keying disc #98-221-2523-500 21. Maintenance Kit #98-680-3720-0002 Pressure and Vacuum Includes 1 each of Items #3,6,7,8,10,11 Page 136 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Beacon Medaes/Breakdowns/Diamond II Series Repair parts are no longer available for Diamond II outlets. These outlets must be converted to a Diamond III outlet to correct problems. 3 EASY STEPS 1. Select appropriate Conversion Kit(s); Pressure gases (O2, N2O, Medical air & CO2) Vacuum & Evacuation Above Kits include10 each of Item #’s 3, 5, 6 & 7 2. Order desired quantity of secondary check units, Item number 4 below 3. Select appropriate finishing assembly Oxygen Nitrous Oxide Vacuum Medical air Carbon Dioxide WAGD (Evacuation) MERCURY MEDICAL® Page 137 #98-221-3976-870 #98-221-3976-871 #98-221-3970-500 #98-221-3982-800 #98-221-3982-801 #98-221-3982-802 #98-221-3982-803 #98-221-3982-804 #98-221-3982-805 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Breakdowns/Diamond III Series Diamond III Series (Stamped with 300 Series Number on Back Side of Cover Plate, #14) Description Description Item Number 1. Back Body #98-0221-3954-701 2. O-ring #98-0210-0706-300 3. Spring, bronze for Pressure Gases (10 Each) #98-0203-3217-870 Stainless Steel for Vacuum and WAGD (10 each) #98-0203-3218-870 4. Secondary Check #98-0221-3970-500 5. O-ring (10 each) #98-0210-0491-870 6. Rubber Bushing (10 Each) #98-6803-2030-000 7. Ring, 1” Spirolex (10 Each) #98-6803-2030-001 8. Back Plate 9. Screw, 8 x 5/8 (2) #98-6812-2000-075 10. Ring, 1.125” Spirolex #98-6812-2000-404 11. Spring (10 Each) #06-833436PG 12. Piston (10 Each) #98-0221-1587-870 13. Gasket (2) #98-0210-0070-300 14. Cover Plate (with logo) #98-0221-1528-100 15. Front Body Cylinder #98-0221-3960-500 Item Number 16. O-ring (10 Each) #98-0210-0491-870 17. Washer #98-0402-1130-300 18. Lock-in Adapter Spring #98-0203-5129-870 (10 Each) 19. Detail for replacing spring assembly 20. Keying Disc Wall Mounted Console Mounted Oxygen #98-0221-1500-600 #98-0221-3919-600 Nitrous Oxide #98-0221-1501-600 #98-0221-3915-600 Vacuum #98-0221-1502-600 #98-0221-3920-600 Medical Air #98-0221-1508-600 #98-0221-3921-600 Carbon Dioxide #98-0221-1509-600 N/A WAGD (Evacuation) #98-0221-1507-600 N/A Nitrogen N/A N/A 21. Eyelet (2), (50 Each) #98-0203-5643-870 22. Finish Plate #98-0221-1464-500 23. Screw, 6-32 x 1-1/2” (2) #98-0140-6324-124 Secondary Check Repair Kit for 10 Outlets 10 Each of items 3, 5, 6 and 7 for Pressure Gases #98-0221-3976-870 Secondary Check Repair Kit for 10 Outlets 10 Each of items 3, 5, 6 and 7 for Vacuum and WAGD #06-290803PG Primary Check Repair Kit for 10 Outlets Repair Kit with 10 Each of items 5, 11 12, 16, 17 and 18; and 30 each of item 21 #06-290804PG MERCURY MEDICAL® Page 138 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Beacon Medical (Puritan-Bennett) Series “A” 3 6 Quick Connect 8 4 10 11 10 12 D.I.S.S. 14 12 SEE next page for ordering Numbers MERCURY MEDICAL® Page 139 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Beacon Medical (Puritan-Bennett) Series “A” Repair Parts for Series A Outlets are available on a limited basis. Outlets requiring obsolete parts can be updated. PART ITEM NUMBER DESCRIPTION 3. #06-814051 4. #06-826001 6. #06-815301 8. #06-815321 10. #06-230240 #06-230241 #06-230242 #06-230243 #06-211170 #06-211171 #06-211172 #06-211173 11. #06-425211 #06-425212 #06-425213 #06-425214 #06-425215 12. #06-230320 #06-230321 #06-230322 #06-230323 #06-230324 #06-230300 #06-230301 #06-230302 #06-230303 14. #06-230056 #06-230057 Screw (Tie Bar) Tinnerman 6/32 Speed nut Screw (Block Mounting) Shoulder Screw D.I.S.S. Valve (O2) D.I.S.S. Valve (N2O) D.I.S.S. Valve (Medical air) D.I.S.S. Valve (Vac) Quick Connect Valve (O2) Quick Connect Valve (N2O) Quick Connect Valve (Medical air) Quick Connect Valve (Vac) Escutcheon (Single) Escutcheon (Double) Escutcheon (Triple) Escutcheon (Quad) Escutcheon (Quint.) D.I.S.S.-Insert Plate Assy. (O2) (Includes Dust D.I.S.S.-Insert Plate Ass. (N2O Cover/Chain) D.I.S.S.-Insert Plate Assy. (Medical air) D.I.S.S.-Insert Plate Assy. (Vac) D.I.S.S.-Insert Plate Assy. (N2) Q.C. - Insert Plate Assy. (O2) Q.C. - Insert Plate Assy. (N2O) Q.C. - Insert Plate Assy. (Medical air) Q.C. - Insert Plate Assy. (Vac) Dust Cover & Chain Assy. (O2) Dust Cover & Chain Assy. (N2O, Medical air, Vac, N2) MERCURY MEDICAL® Page 140 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Breakdowns/Chemetron (NCG) 500 SERIES Quick Connect Model Description 1. 6” copper tube connection to medical gas or vacuum supply line. 2. Swivel base housing 3. Back box (Field replacement of items 1, 2 and 3 is not feasible). 4. Secondary check kit (6 pk): A. Secondary check B. Washer C. Housing D. Deflator spring assembly 5. Housing base O-Ring (12/pk) 6. Poppet 7. Poppet O-Ring(12/pk) 8. Valve body assemblies (poppet and O-Rings) Valve body with poppet pressure Valve body with poppet vacuum Valve body with poppet pressure (4 pk) 9. Valve body O-ring (12/pk) 10. Face plate assemblies: Oxygen Nitrous Oxide Vacuum Medical Air WAGD (Evacuation) CO2 O2/CO2 11. Latch spring kit (12 pk) 12. Faceplate mounting screw kit (48/pk) 13. Vacuum spring kit (6/pk) 14. Test plug kit (12pk) 15. Back box mounting screw/fastener kit (24pk) D.I.S.S. Model Item Number #32-64-90-0650 #32-64-90-0185 #32-98-90-0002 #32-64-90-0097 #32-64-90-0620 #32-64-90-0621 #32-64-90-0653 #32-64-90-0186 #32-64-91-1501 #32-64-91-1504 #32-64-91-1502 #32-64-91-1503 #32-64-91-1506 #32-64-91-1507 #32-64-91-1508 #32-64-90-0096 #32-64-90-0031 #32-64-90-0034 #32-64-90-0651 #32-64-90-0652 Item Number Description #32-64-90-0029 16. D.I.S.S. poppet all service except Oxygen, vacuum, evacuation #32-64-90-0028 17. D.I.S.S. poppet oxygen, vacuum, evacuation 18. D.I.S.S. valve body, key ring and poppet assembly: Oxygen #32-64-90-0631 Nitrous Oxide #32-64-90-0633 #32-64-90-0632 Vacuum #32-64-90-0634 Medical Air #32-64-90-0638 WAGD (Evacuation) #32-64-90-0636 N2 #32-64-90-0635 CO2 #32-64-90-0637 O2/CO2 19. D.I.S.S. Face Plate Assemblies: #32-64-91-1561 Oxygen #32-64-91-1564 Nitrous Oxide #32-64-91-1562 Vacuum #32-64-91-1563 Medical Air #32-64-91-1566 WAGD (Evacuation) #32-64-91-1565 N2 #32-64-91-1567 CO2 #32-64-91-1568 O2/CO2 #32-64-90-0030 20. D.I.S.S. face plate screw kit (24/pk). 21. D.I.S.S. dust cap and chain assembly: #32-64-90-0098 Oxygen #32-64-90-0100 Nitrous Oxide #32-64-90-0099 Vacuum #32-64-90-0101 Medical Air #32-34-90-0026 22. D.I.S.S. poppet O-Ring only 6/Pk 6/Pk 6/Pk 6/Pk 12/Pk Figure #1 - Initial Setting Lightly lubricated* O-Ring shown loaded around rod and in installer assembly cavity. Figure #2 - Operation Slide bracket assembly up or down until rod lines up with center of poppet. MERCURY MEDICAL® Page 141 #32-64-90-2060 O-Ring installation tool only *Medical Gas Outlet Lubrication (1 ox.) #32-64-90-2111 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Breakdowns/Chemetron (NCG) 348, 378, 400 Series D.I.S.S. Quick Connect 348 Series Description Item Number 378 Series (Discontinued) Description Item Number #32-64-90-0096 12/Pk #32-64-90-0003 6/Pk (Oxygen) #32-64-90-0004 6/Pk (Vacuum) #32-64-90-0005 6/Pk (Medical air) #32-64-90-0006 6/Pk (Nitrous Oxide) 348 Series Only #32-64-90-0009 6/Pk (Oxygen) #32-64-90-0155 6/Pk (Vacuum) #32-64-90-0011 (Medical air) 6/Pk #32-64-90-0012 6/Pk (Nitrous Oxide) 18. Face Plate - 400 Series #32-64-92-0176 (Oxygen) #32-64-92-0177 (Vacuum) #32-64-92-0178 (Medical air) #32-64-91-4003 (Nitrous Oxide) #32-64-91-4015 (Carbon Dioxide) #32-64-91-4020 (Oxygen/CO2) #32-64-91-4021 WAGD (Evac.) Ceiling Column Faceplate #32-83-90-4021 WAGD (Evac.) 19. Face plate screws #32-64-90-0031 48/Pk 20. Poppet #32-64-90-0028 (Oxygen and vacuum) *Chemetron Outlet Stations manufactured with rear entry of #32-64-90-0029 pigtail (1) use Secondary Check Valve Catalog No. #32-64-90- 21. Poppet (N2O, Medical air, CO2) 0152 Items 5 & 9 make up kit, 6 kits/pk 22. Poppet O-Ring, D.I.S.S #32-34-90-0026 12/Pk 23. Valve Body #32-64-90-0157 (Oxygen) #32-64-90-0078 (Vacuum) #32-64-90-0079 (Nitrous Oxide) #32-64-90-0080 (Medical air) 1. 6” Copper tube for connection N/A to gas or vacuum supply line 2. Mounting Box N/A 3. Back box (Field replacement of items 1,2 N/A and 3 are not feasible) 4. Mounting block O-ring #32-64-90-0185 12/Pk 5. Secondary check valve #32-64-90-0151* 6/Pk 6. Secondary check washer #32-64-90-0107 12/Pk 7. Housing #32-64-90-0002 8. Housing O-Ring #32-64-90-0185 12/Pk 9. Secondary check spring #32-64-90-0151* 6/Pk 10. Vacuum Spring #32-64-90-0034 6/Pk 11. Test Plug #32-64-90-0001 6/Pk 12. Poppet #32-98-90-0002 13. Poppet O-Ring #32-64-90-0097 12/Pk 14. Valve body, #32-64-90-0039 12/Pk Quick-connect (Pressure without poppet) Valve body, #32-64-90-0040 Quick-connect (Vacuum without poppet) Valve body assembly, #32-64-90-0180 (Pressure, Quick-connect with poppet) Valve body assembly, #32-64-90-0181 (Vacuum, Quick-connect with poppet) 15. Valve body O-Ring #32-64-90-0186 12/Pk MERCURY MEDICAL® 16. Face plate springs 17. Latch button (indicia) 378, 400 series only 400 Series Page 142 Description Item Number 24. Face Plate -460 Series #32-64-91-6001 (Oxygen) #32-64-91-6002 (Vacuum) #32-64-91-6004 (Medical air) #32-64-90-6003 (Nitrous oxide) 25. Latch Button #32-64-90-0020 (Oxygen) 6/Pk #32-64-90-0021 (Vacuum) 6/Pk #32-64-90-0022 (Medical air) 6/Pk #32-64-90-0023 (Nitrous Oxide) 6/Pk 26. Face plate screws #32-64-90-0030 24/Pk 27. Dust cap and chain #32-64-90-0098 (Oxygen) 6/Pk #32-64-90-0099 (Vacuum) 6/Pk #32-64-90-0100 (Nitrous Oxide) 6/Pk #32-64-90-0101 (Medical air) 6/Pk 28. O-Ring Kit. #32-98-90-0003 (Consists of 12 each. of items 4, 13, 15) (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Breakdowns/Oxequip 07 (O.E.S.) SERIES QUICK CONNECT Repair components are limited. Existing outlets may be modernized/converted from the detailed list below. All conversions require additional purchase of drill indexing template(s) for each gas. Parts for 07 Series are available on a limited basis. Modernizations/Conversions (Requires use of drill indexing template) ‘07 SERIES Q.C. & D.I.S.S. TO Med*Star D.I.S.S. Item Number Description #21-2227-H Oxygen (Template not included) #21-2227-J Vacuum (Template not included) #21-2227-K Nitrous Oxide (Template not included) #21-2227-M Nitrogen (Template not included) #21-2227-L Medical air (Template not included) ‘07 SERIES Q.C. & D.I.S.S. TO Med*Star Q.C. #21-1227-C Oxygen (Template not included) #21-1327-C Vacuum (Template not included) #21-1427-C Nitrous Oxide (Template not included) #21-1527-C Medical air (Template not included) (Nitrogen not Available) 1. 2. Med*Star Drill Indexing Templates Must be used when changing ‘07 Series to Med*Star #21-1227-G #21-1327-G #21-1427-G #21-1527-G #21-1627-G Oxygen, drill indexing template Vacuum, drill indexing template Nitrous Oxide, drill indexing template Medical air, drill indexing template Nitrogen, drill indexing template 3. 4. 5. 6. Description Item Number Coverplate Screw Coverplate Oxygen Nitrous Oxide Medical Air Vacuum Overhang Spacer Depth Spacer Camplate Assembly Seat Retainer Bushing Oxygen Nitrous Oxide Medical Air Vacuum 21-1207-150 Med*Star QUICK-CONNECT COMPONENT IDENTIFICATION 1 2 145 6 7 8 21-1207-11 21-1407-11 21-1507-11 21-1307-11 10.+ 11.+ 12.+ 13.+ 14. Detail No. 1. 2. 4. 5. 6. 7. B A 9 10 21-1207-B 21-1407-B 21-1507-B 21-1307-B 21-1207-37 21-1207-35 21-1207-M 7. 8. 9. 11 12 10 13 8. 9. 10. 11.+ A. Pressure Outlet Slide Valve Assembly #21-1227-Y B. Pressure Outlet Internal Parts Kit #21-1227-X 3. B A 5 6 7 8 9 4. 5. 10 11 9 12 6. A. Pressure Outlet Slide Valve Assembly #21-1227-Y B. Pressure Outlet Internal Parts Kit #21-1227-X Item Number Seat Washer Slide Valve Slide Valve Spring pressure vacuum Ball Check Retainer Bushing Ball Check “O” Ring Ball Check Ball Check Spring Outlet Body 21-1217-10 21-1207-69 21-1207-67 21-1307-12 21-1207-64 21-1247-11 21-3727-10 21-1207-66 Description Item Number Coverplate Screw 24/PK #21-1207-150-RPL Coverplate Tapered side #21-1227-P Straight #21-2027-X Depth Spacer #21-1207-172 Camplate Assembly 5/PK #21-1227-M-RPL Molded Dust Cover #21-1227-41 Color-coded Pin-Indexed Tumbler oxygen #21-1207-162 nitrous oxide #21-1407-62 medical air #21-1507-62 vacuum #21-1307-62 Seat Washer #21-1217-10 Slide Valve #21-1207-69 Slide Valve Spring pressure #21-1207-67 vacuum #21-1307-12 Ball Check Retainer Bushing #21-1227-W with Seal Ball Check #21-3727-10 Ball Check Spring #21-1207-67 Outlet Body N/A + Not used in vacuum outlets. ++ Not used on ceiling outlets. Detail No. 1. 2.++ Med*Star® D.I.S.S. COMPONENT IDENTIFICATION 1 231 4 12.+ 10.+ 13. Description 7. 8. 9. 10.+ 11.+ 9.+ 12. Description Item Number Coverplate Screw #21-1207-150 Dust Cap and chain Oxygen #21-1218-A All others #21-1218-T Coverplate tapered side #21-2227-P straight side #21-2227-X Depth Spacer #21-2227-17 Color-coded Pin Indexed Tumbler oxygen #21-2227-A nitrous oxide #21-2227-C medical air #21-2227-D vacuum #21-2227-B nitrogen #21-2227-E Depressor Tube oxygen (1-3/4-44.45mm) #21-2207-12 all others (1- 5/8-41.275mm) #21-2227-16 Seat Washer #21-1217-10 Slide Valve #21-1207-69 Slide Valve Spring pressure #21-1207-67 vacuum #21-1307-12 Ball check Retainer Bushing With seal #21-1227-W Ball Check #21-3727-10 Ball Check Spring #21-1207-67 Outlet Body N/A + Not used in vacuum outlets. ++ Not used on ceiling outlets. MERCURY MEDICAL® Page 143 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Conversion Kits Converts Most Quick Connect Style Outlets to D.I.S.S. (Screw-On) F NTAL Features The Frontal D.I.S.S. medical gas conversion outlets represent the most technically advanced means of providing medical gas connections to the central piping system. • Unique patented valve cartridge. • Gas specific D.I.S.S. outlet body. • Double permanent identification for the user service identified on both connector and faceplate. • Full faceplate color coding. • Strength of connections eliminates unintended disconnects. • Provides support for dispensing equipment without the use of additional brackets. Specifications The medical gas wall outlet shall be Frontal D.I.S.S. The outlet name plate shall be permanently color coded and sealed behind a lexan protective cover. To prevent leaks Medical Gas Outlets. The outlets shall incorporate within the finished wall, there shall be no rubber o-rings for a full faceplate sized color coding. gas seal behind the faceplate. The name of the gas service shall be permanently embossed on the outlet sub-mounting The outlets shall be capable of supporting plate and the chrome plated brass outlet body. dispensing equipment without the use of slide brackets. Medical gas outlets shall be cleaned for oxygen service in accordance with the current Compressed Gas Association The medical gas outlets shall be designed so that (CGA) Pamphlet G-4.1, capped and placed in a protective once installed, routine service of both the primary and secondary check valves can be accomplished container for shipment. without removing the nameplate or gas specific positions. The primary check valve shall be unitized The outlets shall be installed in strict accordance with and of the cartridge type and the primary check can manufacturer’s instructions, and tested before use in be removed for service without shutting off the gas. conformance with local and federal codes. MERCURY MEDICAL® Page 144 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Conversion Kits Standard Conversion Outlets* Item Number Medical Air #GP-F3816 Chemetron/NCG 5/8-27 #GP-F3916 Chemetron/NCG 3/4-16w/ Flange #GP-F3116 Melco/Foregger/Linde 9/16-18 #GP-F4016 Ohmeda Diamond Series 1 #GP-F4116 Ohmeda Diamond Series II/III #GP-F4216 Ohmeda 40 Series #GP-F3216 Oxequip 07 5/8-24 #GP-F3616 Oxequip Med*Star 5/8-27 #GP-F3716 Oxequip Med*Star (smooth bore) #GP-F3316 Puritan Series 73 5/8-24 #GP-F3416 Puritan Litharge 1/4 NPT #GP-F3516 Puritan Series A (not threaded) #GP-F4616 Puritan Series B #GP-F4316 Schrader 1/4 NPT #GP-F4416 Schrader 5/8-24 #GP-F4516 Schrader 5/8-27 Nitrogen Nitrous Oxide Oxygen #GP-F3804 #GP-F3824A Vacuum #GP-F3822 #GP-F3904 #GP-F3924A #GP-F3922 #GP-F3104 #GP-F3124A #GP-F3122 #GP-F4004 #GP-F4024A #GP-F4022 #GP-F4104 #GP-F4124A #GP-F4122 #GP-F4204 #GP-F4224A #GP-F4222 #GP-F3212 #GP-F3204 #GP-F3224A #GP-F3222 #GP-F3612 #GP-F3604 #GP-F3624A #GP-F3622 #GP-F3712 #GP-F3704 #GP-F3724A #GP-F3722 #GP-F3304 #GP-F3324A #GP-F3322 #GP-F3404 #GP-F3424A #GP-F3422 #GP-F3504 #GP-F3524A #GP-F3522 #GP-F4604 #GP-F4624A #GP-F4622 #GP-F4304 #GP-F4324A #GP-F4322 #GP-F4404 #GP-F4424A #GP-F4422 #GP-F4504 #GP-F4524A #GP-F4522 #GP-F3112 * Trim plates are available for multiple outlets and can be installed against the wall behind the outlet faceplate. Trim plates are custom-made based on the distance between outlet centers. MERCURY MEDICAL® Page 145 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Conversion Kits/Chemetron (NCG) Valve Body/O-Ring Identification Chart (Chemetron Outlets) Shown below are actual size drawings of these parts. Check the drawing to verify your catalog number. 1. 2. 3. 4. INSTALLATION TOOL #32-65-10-1001 MERCURY MEDICAL® Page 146 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Conversion Kits/Chemetron (NCG) NOTE: EARLY PURITAN OUTLETS USED LITHARGE (combination of white lead and glycerin). To secure the Quick-Connect Valve to the Outlet Block. Use of mild heat is recommended to loosen this connection. WALL SURFACE LITHARGED CONNECTION CONVERT FROM PURITAN-BENNETT OUTLETS Wall Surface SPRING AND POPPET Quick connect Valve Actuator Remove and Discard Spring Wall Surface Puritan-Bennett Outlet with Litharged Connection Adapter Housing PURITAN BENNETT SERIES 73 Outlet Remove and discard Quick connect valve Keyed Housing Quick connect Valve Stainless Steel Trimplate STAINLESS Remove And STEEL Discard Plastic Insert Plastic Plate W/Stainless Inserts Select Pop Rivet to match Depth of Box Base Housing Valve Body Keyed Per Service Back Spacer Plate Some new Puritan Outlets have a keyed housing ring that is partially riveted to the base. This rivet must be drilled out before removal can proceed. Most housing rings are attached by two screws. Stainless Steel Plate NOTE: Poppet and Brass Check Bushing must be in position for proper function. 1” Long Screws provided SINGLE WALL OUTLET INSTALLATION Spacing determines Oxygen Vacuum Medical Air Nitrous Oxide #32-65120101 #32-65120102 #32-65120104 #32-65120103 MERCURY MEDICAL® Quick Connect Latch Mechanism proper Puritan conversion for multi-gang outlets Page 147 MULTIPLE WALL OUTLET INSTALLATION Oxygen Vacuum Medical Air #32-65120501 #32-65120502 #32-65120504 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Modernization Kits/Accessories Economical ... Easy to do! Chemetron modernization kits are available for updating of outlets in walls, patient bedside consoles, prefabricated modular wall systems, ceiling columns as well as for Vacpak respiratory and suction service cabinets. And this updating can be done as the need arises, and/or time permits. They have an attractive stainless steel fascia with a satin finish. The fascia has a color coded tab for easy release of secondary equipment. It is also safety-keyed by gas service to the existing back box. The number of parts and assembly has been simplified since a rugged latching mechanism is now part of the fascia assembly. Many kits are available with a complete valve body assembly offering improved flow characteristics. The modernization kits are designed to allow hospital maintenance personnel to easily and economically update older version NCG outlets and enjoy all the benefits of the new, simplified 400 Series Outlet. The following illustrates the ease with which this updating can be carried out. STEP 1 a. Remove and discard cover screws and old cover plate. b. Remove and discard stabilizer screws and and stabilizer, if applicable. c. Remove and discard latch screws and latch (except on 148 series). d. Remove valve body assembly if it is to be replaced with a new valve body assembly. STEP 2 a. Mount conversion guard to outlet box with tamper-proof screws as illustrated. The gas service is stamped into the conversion guard for identification. CAUTION: Extreme care must be taken to ensure that the Conversion Guard included with the kit is used for the specific gas service for which it is intended. This is necessary to avoid the possibility of interchanging gases. b. Insert new valve body assembly (if applicable). c. Attach 400 Series fascia. The protruding “Keys” affixed to the fascia must match the “Keyhole Slots” in the conversion guard. It may be necessary to adjust the valve bodies inward or outward for optimum fascia fit. Matching of “Key” and “Slot” recognize importance of matching gas services. Do not rely on pipe decals- confirm outflow! When ordering multiple service Modernization Kits a determination of the distance between gas service is important. The center-to-center measurement represents the distance between vertical, imaginary line extending through the center of the poppet or gas opening. The distance between gas service is often referred to as a “Blank.” The center-to-center measurement between oxygen and vacuum, for example, on an outlet with no “BLANKS” is 1-13/16”. Multiple outlets with one “BLANK” between gas services have a 3-5/8” distance. Outlets having a 5-7/16” center-to-center measurement would have two “BLANKS” between gas service. NOTE: State gas service reading left to right as you look at the face plate. In the photo above, the sequence for ordering purposes is Oxygen-B-B-Air-B-B-Vac (B=Blank). For ease of Identification, Modernization Kits are grouped by single or multiple gas service and with or without valve body assembly. MERCURY MEDICAL® Catalog Number #32-49100001 #32-49100002 #32-49100003 #32-49100004 #32-49100005 #32-49100006 #32-49100007 #32-49100009 #32-49100012 #32-49100013 #32-49100014 #32-49100016 #32-49100020 #32-49100021 #32-49100036 #32-49100038 #32-49100040 #32-49100041 #32-49100042 #32-49100043 #32-49100044 #32-49100045 #32-49100047 #32-49100050 #32-49100055 #32-49100057 #32-49100058 Gas Service Includes Valve Body Assembly Oxygen NO Vacuum NO Medical air NO Vac/Oxy NO Oxy/Vac NO Vac/Medical air NO Vac/Oxy NO Oxy/Medical air Yes Vacuum Yes Nitrous Oxide Yes Medical air Yes Oxy/Vac Yes Vac/Vac NO Oxy/Vac/Medical air NO Oxygen Yes Vac/Oxy Yes Vac/Oxy Yes Vac/Medical air Yes Centron Oxy Yes Centron Vac Yes Vac/Oxy/Vac Yes Oxy/Medical air/Vac Yes Oxy/N2O/Medical air Yes /Vac Medical air/Medical air Yes Vac/N2O/Oxy Yes Oxy/Vac Yes Oxy/N2O/Vac Yes Center-to-Center Measurement NA NA NA 1 13/16” (4.60cm) 3 5/8” (9.21 cm) 3 5/8” (9.21 cm) 3 5/8” (9.21 cm) 3 5/8” (9.21 cm) NA NA NA 3 5/8” (9.21 cm) 1 13/16” (4.60cm) 1 13/16” (4.60cm) NA 1 13/16” (4.60cm) 3 5/8” (9.21cm) 3 5/8” (9.21cm) NA NA 1 13/16” (4.60cm) 1 13/16” (4.60cm) 1 13/16” (4.60cm) 1 1 1 1 13/16” 13/16” 13/16” 13/16” (4.60cm) (4.60cm) (4.60cm) (4.60cm) Extended Barrel is a special Valve Body or Faceplate. Always Modernize with a new valve body. Page 148 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Modernization Kits/Chemetron 148 Series Outlets 248 Series Outlets 248 Series Number #32-49110001 #32-49110002 #32-49110004 #32-49110006 #32-49110007 #32-49110008 #32-49110009 #32-49110010 #32-49110011 #32-49110015 #32-49110016 #32-49110017 #32-49110019 #32-49110023 #32-49110033 #32-49110037 #32-49110045 #32-49110046 #32-49110047 #32-49110048 #32-49110049 #32-49110054 Catalog Service Gas Valve Body Assembly Oxygen NO Vacuum NO Oxy/Vac Yes Oxygen Yes Vacuum Yes Nitrous Oxide Yes Medical air Yes Oxy/Vac Yes Oxy/Vac Yes Medical air NO Vac/Oxy NO Oxy/Oxy Yes Oxy/N2O/Vac NO Oxy/Medical air/Vac Yes Palco console Yes Oxy Auth console Yes Oxy Oxy/N2O/Medical air Yes Vac/Medical air/Oxy Yes Vac/N2O/Oxy Yes Vac/Oxy Yes Vac/Oxy/Vac Yes Oxy/Vac/Vac Yes Includes Center-to-Center Measurement NA NA 3 5/8”(9.21cm) NA NA NA NA 3 5/8” (9.21 cm) 5 7/16” (13.81 cm) NA 3 5/8” (9.21 cm) 3 5/8” (9.21 cm) 1 13/16” (4.60cm) 1 13/16” (4.60cm) NA NA 1 1 1 3 5 1 13/16” (4.60cm) 13/16” (4.60cm) 13/16” (4.60cm) 5/8” (9.21 cm) 7/16”(13.81 cm) 13/16” (4.60cm) 246 SERIES (Not Shown) Catalog Number Gas Service #32-49170001 #32-49170002 #32-49170003 #32-49170004 Oxygen Vacuum Nitrous Oxide Medical air Includes Valve Body Assembly Yes Yes Yes Yes Center To Center Measurement NA NA NA NA 248 Valve Body 1 5/8” 148 Valve Body 1 1/8” Seal Surface Area 148 Series Catalog Number #32-49120001 #32-49120002 #32-49120004 #32-49120005 #32-49120006 #32-49120007 #32-49120008 #32-49120009 #32-49120010 #32-49120011 #32-49120012 #32-49120015 #32-49120016 #32-49120017 #32-49120020 #32-49120023 #32-49120024 #32-49120040 Gas Service Includes Valve Body Assembly Oxygen NO Vacuum NO Oxy/Vac NO Medical air NO Oxygen Yes Vacuum Yes Nitrous Oxide Yes Medical air Yes Oxy/Vac Yes Oxy/Vac Yes Vac/Oxy Yes Oxy/N2O Yes Vac/Oxy NO Oxy/Vac NO Oxy/Medical air/Vac Yes Oxy/N2O NO Vac/Vac NO Vac/Oxy Yes Center-to-Center Measurement NA NA 5 7/16”(13.81 cm) NA NA NA NA NA 3 5/8” (9.21 cm) 5 7/16” (13.81 cm) 3 5/8” (9.21 cm) 3 5/8” (9.21 cm) 1 13/16” (4.60cm) 3 5/8” (9.21 cm) 1 13/16” (4.60cm) 3 5/8” (9.21 cm) 3 5/8” (9.21 cm) 1 13/16” (4.60cm) 146 SERIES (Not Shown) Catalog Number Gas Service #32-49160001 #32-49160002 #32-49160003 Oxygen Vacuum Nitrous Oxide Includes Valve Body Assembly Yes Yes Yes Center-to-Center Measurement NA NA NA Includes Gas Body Assembly Yes Yes Center-to-Center Measurement NA NA 236 Series (Not Shown) Catalog Number Gas Service #32-49180001 #32-49180002 Oxygen Vacuum Seal Surface Area Notch MERCURY MEDICAL® Page 149 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Modernization Kits/Puritan-Bennett/Beacon Medaes The performance and operation of the earlier series of Nellcor Puritan BennettTM (now Beacon Medical) outlets can be improved by installing a Series B Upgrade Kit. Nellcor Puritan-Bennett outlets are identified by design configurations applicable to each of the three outlet series; Litharge, Series 73 and Series A. The complete upgrade kit consists of three component assemblies: 1) a gas service specific outlet valve, 2) a coverplate, and standoff for either 3-1/4” or 5” centerline space outlets and 3) a connector for either litharge, Series 73, or series A outlets. An upgrade program begins with an inventory of the outlet series to be upgraded. The illustration below will aid in identifying the outlet series for ordering the correct upgrade kit. Outlets are best identified by the design of the outlet block. Removal of the coverplate may be necessary to be certain the correct connector is ordered. Outlet Identification and Upgrade Components Update Kits, Item #1, on the following page are used with all outlet series types. Connectors, Items # 2, #3, and #4 are used with specific series types. Coverplates and standoffs, Items #5 through #8 are also used with specific series types. Figure 1 below shows key identification components of three outlet series types while Figure 2 shows the appropriate upgrade components. MERCURY MEDICAL® Page 150 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Modernization Kits/Puritan-Bennett/Beacon Medaes Parts List Item Number #06-232200-00 #06-232201-00 #06-232202-00 #06-232203-00 #06-232209-00 #06-232210-00 #06-232212-00 #06-232213-00 #06-232020-00 #06-232021-00 #06-232022-00 #06-232023-00 #06-232024-00 #06-232025-00 #06-232027-00 #06-232028-00 MERCURY MEDICAL® Description Nellcor Puritan-Bennett Series “B” D.I.S.S. outlet Upgrade Kit Oxygen (U.S. labeling) Nitrous Oxide (U.S. & International labeling) Medical air (U.S. labeling) Vacuum (U.S. labeling) Evacuation ( U.S. and International labeling) Oxygen ( International labeling) Medical air (International labeling) Vacuum (International labeling) Item Number 1a. #06-232029-00 2. #06-232034-00 3. #06-232033-00 4. #06-232032-00 5. #06-325149-00 6. #06-325148-00 7. #06-315014-00 8. #06-315013-00 9. #06-232031-00 Description Series B slide upgrade kit Connector (litharged outlets) Connector (series ‘73 outlets) Connector (series A outlets) Coverplate (5” centerline) Coverplate (3-1/4” centerline) Standoff (5” centerline) Standoff (3-1/4” centerline) Adapter nut assembly (buried outlets) Tools and Service Materials • Heat gun - 400 watt (litharged outlets) • Teflon® tape (litharged outlets) • Truarc retaining ring pliers Nellcor Puritan-Bennett Series • 1/4” pipe thread tap (litharged outlets) “B” quick-connect Outlet Upgrade Kit • Oxygen compatible leak detector solution • Staked connector replacement tool kit Oxygen (U.S. labeling) Nitrous Oxide (U.S. and (P/N #06-138024-00, Series 73 outlets) International labeling) • Phillips head screwdriver Medical air (U.S. labeling) • 5/16” open end wrench Vacuum (U.S. labeling) • 7/8” socket wrench Evacuation (U.S. and International • 11/16” socket wrench labeling) • Pop rivet tool Oxygen (International labeling) • Measuring scale Medical air (International labeling) • No. 30 drill Vacuum (International labeling) • Pliers • Vacuum cleaner (portable) Page 151 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Repair Kits/Chemetron (NCG) Order This Now STARTER REPAIR KIT METHOD ONE Item Number Contents #32-64-90-2023 PARTS KITS Order now or later Quick connect 400 Series Outlet Station Parts Kit #32-64-90-2001 Allows for Service or Repair Carrying case, labeled Common Parts Kit, O-Ring lubricant, O-Ring Service Tool, and space for Parts listed below. O-Rings for all Chemetron (NCG®) Quick Connect and D.I.S.S. outlet stations; Base Housings, vacuum springs, and secondary checks for 348/346, 378/376 and 400/460 series outlets. Provides you with Labeled Organizer Kit Box, valve bodies, poppets, latch tips and buttons, latch springs. Allows you to service or repair Series348, 378, and 400 Quick-Connect station valves and faceplates. Labeled Organizer Kit Box, valve bodies for most commonly used gas services, poppets, dust caps, gas service buttons and screws. Series 346, 376, and 460 D.I.S.S. outlet station valves and faceplates. Series 500 Quick-Connect outlet stations. D.I.S.S. Outlet 460 Series Station Parts Kit #32-64-90-2002 Quick-Connect 500 Series Outlet Station Parts Kit #32-64-90-2005 Labeled Organizer Kit Box, secondary check poppets, tool, valve bodies, springs. High Pressure Nitrogen Outlet Station Parts Kit #32-64-90-2004 Labeled Organizer Kit Box, Dyna-Con Chemetron (NCG) high-pressure valve assemblies, housings, Dyna-Con DynaCon outlet station valves for service tool, knobs, lock washers, nitrogen service. O-rings and seals. METHOD TWO Order This Now Item Number COMPLETE REPAIR KIT #32-64-90-2028 Description Spring Screw Valve Poppet Air Tip Vac Tip O2 Tip N2O Tip N2O Button O2 Button Air Button All of the outlet Stations listed above except 500 and 560 series outlets. Common parts #32-64-90-2023 Item Number Description #32-64-90-0002 Housing #32-64-90-0034 Spring #32-64-90-0001 Test Plug #32-64-90-0151 Secondary Check #32-64-90-0107 Washer #32-64-90-0185 O-Ring #32-64-90-0186 O-Ring #32-64-90-0097 O-Ring #32-64-90-2060 O-Ring Tool #32-64-90-2071 Socket #32-64-90-2072 O-Ring Pick #32-64-90-2111 Lube D.I.S.S. KIT #32-64-90-2002 Item Number Description #32-64-90-0157 O2 valve body #32-64-90-0079 N2O valve body #32-64-90-0078 Vac Valve Body #32-64-90-0080 Air Valve Body #32-64-90-0028 Poppet #32-64-90-0029 Poppet #32-64-90-0182 Screw #32-64-90-0020 O2 Button #32-64-90-0021 Vac Button #32-64-90-0023 N2O Button #32-64-90-0022 Air Button #32-64-90-0098 O2 Cap #32-64-90-0099 Vac Cap #32-64-90-0101 Air Cap #32-64-90-0100 N2O Cap Quantity 24 48 12 24 6 6 6 6 6 6 6 Nitrogen Kit #32-64-90-2004 #32-11-90-0013 Housing #32-11-91-0178 Installation Tool #32-64-90-0120 O-Ring #32-11-91-0176 O-Ring #32-11-91-0179 Dynacon Assy. #32-11-20-0011 Knob #32-64-90-0194 N2 Button Outlet Station Repair Kit - Complete #32-64-90-2028 #32-64-90-2004 N2 Kit #32-64-90-2001 Quick Connect Kit #32-64-90-2002 D.I.S.S. Kit #32-64-90-2023 Common Parts Kit MERCURY MEDICAL® Starter Repair kit Quick Connect parts D.I.S.S. Parts kit High Pressure Parts Kit Repair Service KIT BREAKDOWNS Quick Connect #32-64-90-2001 Item Number #32-64-90-0096 #32-64-90-0031 #32-64-90-0204 #32-64-90-0002 #32-64-90-0011 #32-64-90-0155 #32-64-90-0009 #32-64-90-0012 #32-64-90-0006 #32-64-90-0003 #32-64-90-0005 Contents 2 1 12 12 2 2 6 1 1 1 1 Page 152 Quantity 8 12 6 24 50 100 100 100 1 1 1 1 Quantity 4 2 4 2 12 12 48 6 6 4 6 6 6 6 4 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Ball Valves MERCURY MEDICAL® Page 153 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Ball Valves WITHOUT EXTENSIONS #69-250-20 #69-250-21 #69-250-22 #69-250-23 #69-250-24 #69-250-25 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” (13mm) (19mm) (25mm) (32mm) (38mm) (51mm) All valves are rated at 400 PSIG and are prepared for Oxygen service. Operation from “ON” to full “Off” by simple 90o turn of valve handle. WITH EXTENSIONS BALL VALVE LOCK HANDLE Item Number Valve Size #32-77030002 #32-77030003 #32-77030004 #32-77030005 #32-77030006 #32-77030008 #32-77-03-9206 #32-77-03-9207 #32-77-03-9208 1/2” to 3/4” 1” & 1-1/4” 1-1/2” & 2” (including gauge ports - 1/8” Fe) 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” Pipeline Labels AMPPLAB4X3AIR AMPPLAB4X3CO2 AMPPLAB4X3EVAC AMPPLAB4X3N2 AMPPLAB4X3N2O AMPPLAB4X3OXY AMPPLAB4X3VAC GAUGES #32-77-900571 0-100 PSI Pressure #32-77-900572 0-30” Hg Vacuum #32-77-900573 0-300 PSI Pressure (Nitrogen) PIPELINE LABEL PIPELINE LABEL PIPELINE LABEL PIPELINE LABEL PIPELINE LABEL PIPELINE LABEL PIPELINE LABEL AIR CO2 EVAC N2 N2O OXYGEN VACUUM 500/RL 500/RL 500/RL 500/RL 500/RL 500/RL 500/RL GAS EVAC. VAC. PHOTO FOR REFERENCE ONLY N 2O AIR O2 Actual labels are NFPA compliant MERCURY MEDICAL® Page 154 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375 Gas Outlets/Integrated Flowmeter Medical Oxygen and Medical Air Ranges available: 0-8 LPM, 0-15 LPM, 0-25 LPM Product Benefits Amvex Integrated Flowmeter outlet combines a Dial Flowmeter and a Medical Gas Outlet into a single compact design. The right side port connection has a control knob which allows the user to adjust the flow setting, while the left side port is a direct connection to the gas supply. The Amvex Integrated Flowmeter saves space, reduces construction costs, and ensures healthcare providers always have a Flowmeter when they need one. • Easy to read and determine flow levels • Solid construction and streamlined design • Flow Indicator ball indicates that gas is being delivered • Safest, most convenient way to dispense Oxygen & Medical Air • Minimizes cross contamination • No more lost, chained, or broken Flowmeters • Retrofi t existing outlets • Additional outlet can be used for Specialty Flowmeters, Hoses, or a connection for Ventilators Part Configurator MERCURY MEDICAL® Page 155 (800) 835-MMED n (727) 573-0088 n FAX (800) 990-6375