® INSTRUCTIONS TO USE ››› su n nex ta sk li g h ti n g se r ie s ® Contents General information ........................................................................................ 4 Warranty policy ................................................................................................ 5 About Sunnex task lighting products ........................................................ 6 Symbols ............................................................................................................... 7 Sunnex HT-Series .............................................................................................. 8 Sunnex HS-series ............................................................................................. 10 Sunnex HM-Series ............................................................................................ 12 Sunnex HF-Series ............................................................................................. 14 Sunnex CL-Series .............................................................................................. 16 Sunnex CLB-Series ........................................................................................... 18 Sunnex CLM-Series .......................................................................................... 20 Replacements parts ......................................................................................... 22 Accessories ......................................................................................................... 29 in fo @ s u n nex.s e w w w.s unnex .com 3 ® General Information The task lighting series in this brochure are sold in Sunnex standard design in accordance with information about quality and design stated here, or upon Because halogen bulbs produce significant heat, necessary precautions must be taken to avoid risk of fire and resulting damage. Sunnex will not be held accountable for design changes made after the special inquiry, supplied by Sunnex. Variation may arise in certain components. To avoid risk of injury, all assembly and installation shall be performed by printing of this brochure. This brochure replaces all previous information about the products it personnel with necessary knowledge about the product, its installation and user environment. contains. The products shall, where appropriate, be installed as per applicable installation instructions. The product shall be installed and used in accordance with applicable electrical regulations for the country in which it is used and other applicable regulations in the area. Sunnex is certified according to ISO 9001:2000 in fo @ s u n nex.s e w w w.s unnex.c om 4 ® Warranty policy ››› Warranty Policy Sunnex warrants that its Products shall be free from defects in material and workmanship and this warranty shall remain in force and effect for a period of three (3) years from and after the date of its Delivery (the “Warranty Period”) provided that this warranty shall be subject the following conditions: (b) The Product shall have been used only for the purposes for which it is intended and shall not have been abused, damaged or modified during installation or from usage. (c) Ordinary wear and tear shall not be covered by the terms of this warranty. (d) Written notice to Sunnex of the defective Product shall be given within the Warranty Period. R 75 Minimum bending radius . 90 max If a Product is found to be defective and the provisions of this Section have been complied with Sunnex will repair or replace the Product, at its expense. Other than as herein expressly set forth there are no warranties made or given herein with respect to a product and the warranties given in statement are in lieu of all other warranties, which are hereby disclaimed. In particular, there are no express or implied warranties, and no warranty of merchantability or fitness for a particular purpose. Sunnex will not be liable for any special, indirect, incidental or consequential damage, loss, cost or expense whatsoever arising from the installation or use of a product or from any other cause. ° Maximum force 250 N Direct mounting shall be done on a horizontal surface In order for the Sunnex Warranty Policy to be valid, the instructions to use, as illustrated above, also must be followed. Stockholm, April 21, 2004 Lars A. Lundholm President and CEO, Sunnex in fo @ s u n nex.s e w w w.s unnex .com 5 x. 35 0° The Sunnex Installation Instructions shall have been strictly complied with in all respects by the party performing the installation of the Product; and ma (a) ® About Sunnex task lighting products ››› CHOOSE THE RIGHT LIGHTING ››› DIFFERENT KINDS OF ARMS For the seven different task lighting series available from Sunnex, the name of each lamp model derives from the design of its head. Lighting in the HS-Series, for instance, builds upon the Halogen Spot head. Each lamp head is designed with its own unique properties as regards light ergonomics, heat production, adjustability and impact resistance. Together with each task lighting series, you will find a Lux diagram that shows the intensity and distribution of light produced by each particular lamp. The measurement is taken at a point 0,4 meters, except the Sunnex CLM where the measurement is 0,15 meters, from the light source. Using the Lux diagram, you can select which lighting will produce the particular light qualities you desire. Each lighting series is based on a single lamp head supplemented by one of a variety of different arms, providing you with lighting that suits your needs in the best possible way. Choose between a bendable flexible gooseneck arm, a spotlight or an articulated arm. ››› MOUNTING EQUIPMENT ››› SAFETY STANDARDS Standard mounting equipment for all Sunnex lights is a base for direct mounting. Should you wish to have a different means of attachment, such as a C-clamp or a magnetic base, you can order this separately. All lighting products are designed and manufactured according to applicable safety standards and regulations. Many models have endorsements from both European and American testing institutes. Sunnex is constantly developing the lighting designs, and certain models may have received different approvals since this brochure was printed. Please contact your local dealer, or Sunnex directly, for updated information on which approvals a particular model currently holds. ››› CLASSIFICATION SYSTEM ››› VOLTAGE In most cases, Sunnex task lighting is available for any of the following voltages; 12, 24, 120 and 230V. Make sure that the power supply connection voltage corresponds to the rated voltage, see label on your lamp. All Sunnex lights are equipped with 2,0 meters power cord as standard. in fo @ s u n nex.s e w w w.s unnex.c om 6 To classify lighting equipment for its resistance to contact with, and penetration by, solid objects and water, we use the IP-Class system. Unless otherwise stated, all Sunnex task lighting meets requirements IP20. This is an industry standard, implying a certain resistance to dust. Most Sunnex standard task lights are also available in IP65, which means that it is both dust-proof and water resistant. ››› STANDARD COLOURS The standard colour for Sunnex task lighting, unless otherwise stated, is black. But it is also available in the optional off-white. ® Sunnex – Symbols ››› SAFETY STANDARDS AND REGULATIONS All Sunnex lighting products are designed and manufactured according to the following European safety standards and regulations: ››› EXPLANATION OF OTHER SYMBOLS Replace a broken lens by a new lens Protection class II ››› The CE mark ››› The ENEC mark CE marking is mandatory for products that are to be sold on the EU market. The ENEC mark certifies the compliance of a product with the harmonized European Union standards. Plug-in transformer Low pressure bulb ››› The S mark The S mark is evidence that the product has been tested and approved by Intertek as meeting minimum requirements of prescribed and harmonized European Union standards. ››› The F mark The F mark certifies that the product could be mounted on a flammable surface in accordance with harmonized European Union standards. in fo @ s u n nex.s e w w w.s unnex. com 7 This product must be sorted as Waste from Electrical and Electronic Equipment (WEEE) ® Sunnex HT-Series – 20W Halogen Lux table ››› TECHNICAL DATA Main voltage: cm 40 230V/AC/50Hz or 12/24V AC/DC Nominal effect: 20W Class: II IP-Class: IP20 20 800 lux 0 Equipped with: Electronic plug-in transformer 230V/12V/20W 500 lux Halogen bulb – 20W/G4 20 40 40 ››› MOUNTING INSTRUCTIONS Mount the lamp on a horizontal surface with the four attached M4-screws. Hole pattern, see dimensional drawing on page 9. Available for the Gooseneck arm and Spot arm are also Sunnex mounting accessories; Magnetic base, C-clamp, Wall bracket and Desktop base. Plug in the cordset to 230V main socket. On/off function is handled with switch in lampbase. 20 0 20 40 cm Measured 0,4 meters from the light source. ››› NOTE Use only Sunnex original parts to secure the function and performance of Sunnex lighting-series. If the lens is broken, it must be replaced by a new lens. Contact your local dealer if you are unsure how to handle replacements on Sunnex HT-Series. ››› CHANGE THE HALOGEN BULB Disconnect cordset from main socket. Allow the bulb to cool down for a few minutes. Gently dismantle the front part of lamphead, pull out the broken bulb and replace with a new bulb. Do not touch the bulb with bare hands! Push front part back on to lamp until it snaps in place. in fo @ s u n nex.s e w w w.s unnex.c om 8 ® Sunnex HT-Series – 20W Halogen A Sunnex HT – Gooseneck arm ››› Arm length; 500 mm ››› 230/12V – plug-in transformer ››› 12 or 24V – sub base ››› With swivel joint lamp head 80 30° ››› With or without dimmer (with dimmer - low voltage models only) ››› IP-Class; IP20 500 5 ∅5 90° ››› Colour; Black or White RAL 9002 ››› Dichroic reflector lamp as an option ∅5 60 50 100 30° 80 5 ∅5 90° 70 A B ››› 230/12V – plug-in transformer ››› 12 or 24V – sub base ››› Single swivel joint in lamp head ››› With or without dimmer (with dimmer - low voltage models only) ››› IP-Class; IP20 ››› Colour; Black or White RAL 9002 50 ∅5 60 B Sunnex HT – Spot arm ››› Dichroic reflector lamp as an option in fo @ s u n nex.s e w w w.s unnex .com 9 ® Sunnex HS-Series – 20W Halogen Lux table ››› TECHNICAL DATA Main voltage: 230V/AC/50Hz or 12/24V AC/DC cm 40 Nominal effect: 20W Class: II IP-Class: IP20 or IP65 20 0 Equipped with: Magnetic built-in transformer 230V/12V/20W 1000 lux 500 lux Halogen bulb – 20W/G4 20 40 40 ››› MOUNTING INSTRUCTIONS Mount the lamp on a horizontal surface with the four attached M4-screws. Hole pattern, see dimensional drawing on page 11. Available for the Gooseneck arm and Spot arm are also Sunnex mounting accessories; Magnetic base, C-clamp, Wall bracket and Desktop base. Plug in the cordset to 230V main socket. On/off function is handled with switch in lampbase. 20 0 20 40 cm Measured 0,4 meters from the light source. ››› NOTE Use only Sunnex original parts to secure the function and performance of Sunnex lighting-series. If the lens is broken, it must be replaced by a new lens. The cordset in this product is a non-replaceable type. If the cordset is damaged, the transformer unit has to be replaced, and it should be done by the maufacturer or a person with sufficient electrical knowledge. Contact your local dealer if you are unsure how to handle replacements on Sunnex HS-Series. ››› CHANGE THE HALOGEN BULB Disconnect cordset from main socket. Allow the bulb to cool down for a few minutes. Unscrew the front part of lamphead, pull out the broken bulb and replace with a new bulb. Do not touch the bulb with bare hands! Screw front part back in place. in fo @ s u n nex.s e w w w.s unnex.c om 10 ® Sunnex HS-Series – 20W Halogen A Sunnex HS – Gooseneck arm ››› Arm length; 250, 500 or 700 mm 40 100 ››› 230/12V – integrated transformer base ››› 12 or 24V – sub base 100 250 500 700 250 47 0 ° ››› With or without swivel joint lamp head ››› With or without dimmer (with dimmer - low voltage models only) ››› IP-Class; IP20 or IP65 (IP65 - low voltage models only) ∅ 62 90° Ø 62 C Sunnex HS – Articulated arm ››› 2-section 1000 mm or 3-section 1250 mm arm ››› 12 or 24V – sub base ››› With or without swivel joint lamp head ››› With or without dimmer 130 ››› Colour; Black or White RAL 9002 A ››› IP-Class; IP20 or IP65 50 60 0 53 ∅5 ››› Colour; Black/Nickelplated steel 60 0 10 115 ››› 12 or 24V – sub base ››› Single or double swivel joint lamp head 100 15° ››› With or without dimmer (with dimmer - low voltage models only) ››› IP-Class; IP20 or IP65 (IP65 - low voltage models only) ››› Colour; Black or White RAL 9002 in fo @ s u n nex.s e w w w.s unnex .com 11 C Ø7 60 44 B 90 ° ∅5 B Sunnex HS – Spot arm ››› 230/12V – integrated transformer base 50 90 44 65 ® Sunnex HM-Series – 35W Halogen Lux table ››› TECHNICAL DATA Main voltage: 230V/AC/50Hz or 12/24V AC/DC cm 40 Nominal effect: 35W Class: II IP-Class: IP20 or IP65 Equipped with: Electronic built-in transformer 230V/12V/35W 20 0 Halogen bulb – 35W/GY6.35 2000 lux 1000 lux 500 lux 20 40 40 ››› MOUNTING INSTRUCTIONS Mount the lamp on a horizontal surface with the four attached M4-screws. Hole pattern, see dimensional drawing on page 13. Available for the Gooseneck arm and Spot arm are also Sunnex mounting accessories; Magnetic base, C-clamp, Wall bracket and Desktop base. Plug in the cordset to 230V main socket. On/off function is handled with switch in lampbase. 20 0 20 40 cm Measured 0,4 meters from the light source. ››› NOTE Use only Sunnex original parts to secure the function and performance of Sunnex lighting-series. If the lens is broken, it must be replaced by a new lens. The cordset in this product is a non-replaceable type. If the cordset is damaged, the transformer unit has to be replaced, and it should be done by the maufacturer or a person with sufficient electrical knowledge. Contact your local dealer if you are unsure how to handle replacements on Sunnex HM-Series. ››› CHANGE THE HALOGEN BULB Disconnect cordset from main socket. Allow the bulb to cool down for a few minutes. Unscrew the screws holding the front part of lamphead, pull out the broken bulb and replace with a new bulb. Do not touch the bulb with bare hands! Screw front part back in place. in fo @ s u n nex.s e w w w.s unnex.c om 12 ® Sunnex HM-Series – 35W Halogen A Sunnex HM – Gooseneck arm ››› Arm length; 250, 500 or 700 mm 40 90° 70 90° 0 47 ››› With or without swivel joint lamp head ››› With or without dimmer (with dimmer - low voltage models only) ››› Safety class; IP20 or IP65 (IP65 - low voltage models only) ››› Colour; Black or White RAL 9002 ∅ 80 A ∅ ››› 2-section 1000 mm or 3-section 1250 mm arm ››› 12 or 24V – sub base 0 53 ››› With or without swivel joint lamp head ››› With or without dimmer ››› Safety class; IP20 or IP65 ››› Colour; Black/Nickelplated steel ››› 12 or 24V – sub base ››› Single or double swivel joint lamp head 100 115 50 0 10 C B ∅ 80 ° 90 ››› With or without dimmer (with dimmer - low voltage models only) ››› Safety class; IP20 or IP65 (IP65 - low voltage models only) ››› Colour; Black or White RAL 9002 ∅7 60 44 ∅5 B Sunnex HM – Spot arm ››› 230/12V – electronic built-in transformer 60 80 C Sunnex HM – Articulated arm 50 ∅5 60 0 10 ››› 230/12V – electronic built-in transformer ››› 12 or 24V – sub base 100 500 700 44 65 in fo @ s u n nex.s e w w w.s unnex .com 13 ® Sunnex HF-Series – 50/75W Halogen Lux table ››› TECHNICAL DATA Main voltage: cm 230V/AC/50Hz or 12/24V AC/DC Nominal effect: 50 or 75W Class: II IP-Class: IP20 or IP65 50W 75W cm 40 40 20 20 0 Equipped with: Electronic built-in transformer 230V/12V/50W 27000 lux 3600 lux 20 Halogen bulb – 50W/GY6.35 or 75W/GY6.35 0 17000 lux 6000 lux 20 900 lux 360 lux 40 1400 lux 500 lux 40 40 ››› MOUNTING INSTRUCTIONS Mount the lamp on a horizontal surface with the four attached M4-screws. Hole pattern, see dimensional drawing on page 15. Available for the Gooseneck arm and Spot arm are also Sunnex mounting accessories; Magnetic base, C-clamp, Wall bracket and Desktop base. Plug in the cordset to 230V main socket. On/off function is handled with switch in lampbase. 20 0 20 40 cm 40 20 0 20 40 cm Measured 0,4 meters from the light source. ››› NOTE Use only Sunnex original parts to secure the function and performance of Sunnex lighting-series. If the lens is broken, it must be replaced by a new lens. The cordset in this product is a non-replaceable type. If the cordset is damaged, the transformer unit has to be replaced, and it should be done by the maufacturer or a person with sufficient electrical knowledge. Contact your local dealer if you are unsure how to handle replacements on Sunnex HF-Series. ››› CHANGE THE HALOGEN BULB Disconnect cordset from main socket. Allow the bulb to cool down for a few minutes. Unscrew the front part of lamphead, pull out the broken bulb and replace with a new bulb. Do not touch the bulb with bare hands! Screw front part back in place. in fo @ s u n nex.s e w w w.s unnex.c om 14 ® Sunnex HF-Series – 50/75W Halogen ››› 230/12V – electronic built-in transformer ››› 12 or 24V – sub base 0 47 110 15° ° ››› With or without swivel joint lamp head ∅ 95 75 ° 250 ››› Safety class; IP20 or IP65 (IP65 - low voltage models only) ››› Colour; Black or White RAL 9002 ∅ 95 110 90° 70 C Sunnex HF – Articulated arm ››› 2-section 1000 mm or 3-section 1250 mm arm A ››› 12 or 24V – sub base ››› With or without swivel joint lamp head 60 50 ∅5 53 ››› Safety class; IP20 or IP65 (IP65 - low voltage models only) ››› Colour; Black/Nickelplated steel 0 100 B Sunnex HF – Spot arm ››› 230/12V – electronic built-in transformer 115 50 ››› 12 or 24V – sub base ››› Single or double swivel joint lamp head B 35° 15° ››› Safety class; IP20 or IP65 (IP65 - low voltage models only) ››› Colour; Black or White RAL 9002 115 60 C Ø 7 60 44 ∅5 75 250 500 700 A Sunnex HF – Gooseneck arm ››› Arm length; 250, 500 or 700 mm 115 115 + 40 44 65 in fo @ s u n nex.s e w w w.s unnex .com 15 ® Sunnex CL-Series – 9/11W Fluorescent tube Lux tables ››› TECHNICAL DATA Main voltage: 230V/50Hz Nominal effect: 9 or 11W Class: IP-Class: 9W cm 11W cm 40 40 200 lux 100 lux II 20 200 lux IP20 645 lux 500 lux 400 lux 300 lux 0 Equipped with: Built-in ballast, 230V 20 Compact fluorescent tube, 9 or 11W - 2 G23 400 lux 1070 lux 0 900 lux 700 lux 20 40 40 40 ››› MOUNTING INSTRUCTIONS Mount the lamp on a horizontal surface with the four attached M4-screws. Hole pattern, see dimensional drawing on page 17. Available for the Gooseneck arm and Spot arm are also Sunnex mounting accessories; Magnetic base, C-clamp, Wall bracket and Desktop base. Plug in the cordset to 230V main socket. On/off function is handled with switch in lampbase. 20 20 0 20 40 cm 40 20 0 20 40 cm Measured 0,4 meters from the light source. ››› NOTE Use only Sunnex original parts to secure the function and performance of Sunnex lighting-series. If the lens is broken, it must be replaced by a new lens. The cordset in this product is a non-replaceable type. If the cordset is damaged, the transformer unit has to be replaced, and it should be done by the maufacturer or a person with sufficient electrical knowledge. Contact your local dealer if you are unsure how to handle replacements on Sunnex CL-Series. ››› CHANGE THE FLUORESCENT TUBE Disconnect cordset from main socket. Unscrew the gable part of lamphead, pull out the broken tube and replace with a new tube. Screw the gable part back in place. in fo @ s u n nex.s e w w w.s unnex.c om 16 ® Sunnex CL-Series – 9/11W Fluorescent tube A Sunnex CL – Gooseneck arm ››› Arm length; 250, 500 or 700 mm ››› 230V – built-in ballast 215 285 70 ››› IP-Class; IP20 70 35 35 ››› Colour; Black or White RAL 9002 200 500 700 270 500 700 Wattage - Comparison 130 130 9W 11 W A 11W ∅5 60 60 50 ∅5 Fluorescent tube – Dulux S 9 and 11W 9W 50 A 60 W 75 W in fo @ s u n nex.s e w w w.s unnex .com 17 Sunnex CLB-Series – 1x24/1x36/2x18/2x24/2x36W Fluorescent tube Wattage - Comparison ››› TECHNICAL DATA Main voltage: 230V/50Hz 1x24 W 1x36 W 2x18 W 2x24 W 2x36 W Nominal effect: 1x24, 1x36, 2x18, 2x24 or 2x36W Class: I IP-Class: IP20 ® 125 W 180 W 200 W 250 W 360 W Equipped with: 230V HF-ballast or conventional ballast Fluorescent tube – Dulux L (left) and Dulux F (right) Compact fluorescent tube; 1x24, 1x36, 2x18, 2x24 or 2x36W Tube model: F – 1xY = 2 G10, L – 2xY = 2 G11 ››› MOUNTING INSTRUCTIONS Mount the lamp on a horizontal surface with the four attached M5-screws. Hole pattern, see dimensional drawing on page 19. Mounting accessory available for the Sunnex CLB-Series; C-clamp. Plug in the cordset to 230V main socket. On/off function is handled with switch in lamphead. ››› NOTE Use only Sunnex original parts to secure the function and performance of Sunnex lighting-series. If the screen is broken, it must be replaced by a new screen. If the cordset is damaged, it must be replaced with a new cordset and it should be done by the manufacturer or a person with sufficient electrical knowledge. Contact your local dealer if you are unsure how to handle replacements on Sunnex CLB-series. ››› CHANGE THE FLUORESCENT TUBE Disconnect cordset from main socket. Unscrew the gable part of lamphead, pull out the broken tube and replace with a new tube. Screw the gable part back in place. in fo @ s u n nex.s e w w w.s unnex .com 18 ® Sunnex CLB-Series – 1x24/1x36/2x18/2x24/2x36W Fluorescent tube 550 A Sunnex CLB – Articulated arm ››› Arm length; 570 + 550 mm 90° 10° ››› 230V – built-in ballast ››› With or without dimmer (only with HF-ballast) ››› With or without flicker-free light ››› With or without daylight fluorescent tube 475 275 375 60° 0 57 ››› IP-Class; IP20 ››› Colour; Black and aluminum 90° 40° 125 125 73 125 A 44 60 ∅ 5.6 60 1x24W cm Lux tables 125 1x36W cm 2x18W cm 2x24W cm 40 40 40 40 20 20 20 20 20 0 0 0 0 2000 lux 1500 lux 1000 lux 500 lux 250 lux 20 40 40 20 0 20 40 2700 lux 2500 lux 1700 lux 1500 lux 20 20 1000 lux 1250 lux 40 cm 40 750 lux 40 20 0 20 40 cm 500 lux 40 20 0 20 40 cm 20 2000 lux 20 40 1000 lux 40 Measured 0,4 meters from the light source. in fo @ s u n nex.s e w w w.s unnex .com 19 0 3000 lux 40 20 0 20 2x36W cm 40 40 cm 4500 lux 3000 lux 1500 lux 40 20 0 20 40 cm Sunnex CLM-Series – 1x24/1x36/2x18/2x24/2x36W Fluorescent tube Wattage - Comparison ››› TECHNICAL DATA Main voltage: 230V/50Hz 1x24 W 1x36 W 2x18 W 2x24 W 2x36 W Nominal effect: 1x24, 1x36, 2x18, 2x24 or 2x36W Class: I IP-Class: IP20 ® 125 W 180 W 200 W 250 W 360 W Equipped with: 230V HF-ballast or conventional ballast Fluorescent tube – Dulux L (left) and Dulux F (right) Compact fluorescent tube; 1x24, 1x36, 2x18, 2x24 or 2x36W Tube model: L – 1xY = 2 G10, F – 2xY = 2 G11 ››› MOUNTING INSTRUCTIONS Mount the lamp on a horizontal surface with the four attached M5-screws. Hole pattern, see dimensional drawing on page 21. Mounting accessory available for the Sunnex CLM-Series; C-clamp. Plug in the cordset to 230V main socket. On/off function is handled with switch in lamphead. ››› NOTE Use only Sunnex original parts to secure the function and performance of Sunnex lighting-series. If the screen is broken, it must be replaced by a new screen. If the cordset is damaged, it must be replaced with a new cordset and it should be done by the manufacturer or a person with sufficient electrical knowledge. Contact your local dealer if you are unsure how to handle replacements on Sunnex CLM-series. ››› CHANGE THE FLUORESCENT TUBE Disconnect cordset from main socket. Unscrew the gable part of lamphead, pull out the broken tube and replace with a new tube. Screw the gable part back in place. in fo @ s u n nex.s e w w w.s unnex.c om 20 ® Sunnex CLM-Series – 1x24/1x36/2x18/2x24/2x36W Fluorescent tube 550 A Sunnex CLM – Articulated arm ››› Arm length; 570 + 550 mm 90° 10° 60° ››› 230V – built-in ballast ››› 3 diopter magnification = 1.75x ››› With or without dimmer (only with HF-ballast) ››› With or without flicker-free light 0 57 ››› With or without daylight fluorescent tube ››› IP-Class; IP20 475 172 375 275 172 172 90° 40° 73 ››› Colour; Black and aluminum 103 A 125 103 103 125 125 44 60 ∅ 5.6 60 1x24W cm Lux tables 1x36W cm 13000 lux 10000 lux 5000 lux 2500 lux 1250 lux 500 lux 0 20 40 40 20 0 20 40 250 lux 20 40 cm 40 20 0 40 20 10000 lux 7500 lux 0 20 0 17000 lux 15000 lux 0 20 10000 lux 5000 lux 2500 lux 20 1250 lux 250 lux 20 40 cm 40 20 0 40 20 40 cm 2500 lux 40 Measured 0,15 meters from the light source. in fo @ s u n nex.s e w w w.s unnex .com 21 19000 lux 20 0 750 lux 20 40 cm 3500 lux 17500 lux 1500 lux 20 12500 lux 750 lux 40 7500 lux 5000 lux 500 lux 40 2x36W cm 40 20 15000 lux 10000 lux 5000 lux 2500 lux 1250 lux 500 lux 0 2x24W cm 40 20 20 2x18W cm 40 40 40 20 0 20 40 cm ® Sunnex HT-Series – Replacement parts ››› SUNNEX HT 20W Component Part No. 1. Lamp head 18055 2. Halogen light bulb 12V/20W 2. Halogen light bulb 24V/20W 15140 15141 3. Reflector 18069 4. Lens, frosted 18009 5. Support ring 18281 6. Lamp shade 18057 7. Distance arc 18010 1 2 3 4 5 6 7 in fo @ s u n nex.s e w w w.s unnex.c om 22 ® Sunnex HS-Series – Replacement parts ››› SUNNEX HS 20W Component Part No. 1. Lamp head 15200 1 2. Halogen light bulb 12V/20W 2. Halogen light bulb 24V/20W 15140 15141 2 3. Reflector, spot 15128 4. Lens, clear 15402 5. Lamp shade 15100 6. Distance arc 15108 3 4 5 6 in fo @ s u n nex.s e w w w.s unnex .com 23 ® Sunnex HM-Series – Replacement parts ››› SUNNEX HM 35W 1 Component Part No. 1. Screw, 3 pcs 15151 2 2. Lamp head 18015 3 3. Halogen light bulb 12V/35W 3. Halogen light bulb 24V/35W 13830 13837 4. Reflector 18003 5. Sealant rings 18014 6. Lens, frosted 18005 7. Lamp shade 18017 8. Distance arc 18008 4 5 6 7 8 in fo @ s u n nex.s e w w w.s unnex.c om 24 ® Sunnex HF-Series – Replacement parts ››› SUNNEX HF 50/75W Component Part No. 1. Lamp head 13800 2. Halogen light bulb 12V/50W 13831 2. Halogen light bulb 12V/75W 2. Halogen light bulb 24V/50W 2. Halogen light bulb 24V/75W 13832 13834 13835 3. Reflector, flood 13821 4. Lens, clear 13825 5. Sealant ring 13816 6. Lamp shade 13810 7. Distance arc 18008 1 7 2 3 4 5 6 in fo @ s u n nex.s e w w w.s unnex .com 25 ® Sunnex CL-Series – Replacement parts ››› SUNNEX CL 9/11W Component Part No. 1. Lamp head, 9W 1. Lamp head, 11W 15810 15820 3. Reflector, 9W 2. Reflector, 11W 15815 15816 3. Lens, 9W 2. Lens, 11W 15861 15862 4. Compact fluorescent tube, 9W 3. Compact fluorescent tube, 11W 15881 15882 5. Gable 15840 6. Screw, 2 pcs 15860 4 2 5 1 3 6 in fo @ s u n nex.s e w w w.s unnex.c om 26 ® Sunnex CLB-Series – Replacement parts ››› SUNNEX CLB 24/36/48/72W Component Part No. 1. Screen, 275 mm lamp head 1. Screen, 375 mm lamp head 1. Screen, 475 mm lamp head 18100 18299 18300 2. Compact fluorescent tube 18W/12 Daylight Dulux L 2. Compact fluorescent tube 24W/12 Daylight Dulux L 2. Compact fluorescent tube 36W/12 Daylight Dulux L 2. Compact fluorescent tube 24W/21 Cool White Dulux F 2. Compact fluorescent tube 36W/21 Cool White Dulux F 2. Compact fluorescent tube 24W/12 Cool White Dulux L 2. Compact fluorescent tube 36W/12 Cool White Dulux L 18022 18023 18024 18025 18026 18027 18028 3. L-Tube support 3. F-Tube support 18170+18171 18172 4. Gable 18089 5. Screw, 4 pcs 15860 in fo @ s u n nex.s e w w w.s unnex .com 27 1 2 3 4 5 ® Sunnex CLM-Series – Replacement parts ››› SUNNEX CLM 24/36/48/72W 5 7 Component Part No. 1. Screen, 275 mm lamp head 1. Screen, 375 mm lamp head 1. Screen, 475 mm lamp head 18100 18299 18300 2. Compact fluorescent tube 18W/12 Daylight Dulux L 2. Compact fluorescent tube 24W/12 Daylight Dulux L 2. Compact fluorescent tube 36W/12 Daylight Dulux L 2. Compact fluorescent tube 24W/21 Cool White Dulux F 2. Compact fluorescent tube 36W/21 Cool White Dulux F 2. Compact fluorescent tube 24W/12 Cool White Dulux L 2. Compact fluorescent tube 36W/12 Cool White Dulux L 18022 18023 18024 18025 18026 18027 18028 3. L-Tube support 3. F-Tube support 18170+18171 18172 4. Magnifying glass 18143 5. Protective cover for magnifying glass 18086 6. Gable 18089 8. Screw, 4 pcs 18157 7. Screw, 4 pcs 15860 9. Washer, 4 pcs 18166 in fo @ s u n nex.s e 6 3 2 4 1 8 w w w.s unnex.c om 28 9 ® Sunnex – Accessories Fits model Info Part No. ››› Screw clamp HT/HS/HM/HF/CL HT/HS/HM/HF/CL Articulated arm CLB/CLM Max. grip 42 mm Max. grip 60 mm Max. grip 70 mm Max. grip 55 mm 14020 14025 12020 18021 HT/HS/HM HF/CL Ø 90 mm Ø 110 mm 14000 12010 HT/HS/HM/HF/CL L-bracket 50 x 80 mm 14030 HT/HS/HM/HF/CL Ø 200 mm 14015 40 ››› ACCESSORY 60 ››› Magnetic base Ø 90 alt. 110 25 ∅5 24 50 ››› Wall mount 20 20 80 60 ››› Desktop base 32 200 in fo @ s u n nex.s e w w w.s unnex .com 29 ® Sunnex – Accessories ››› ACCESSORY ››› Trolley base 60 Fits model Info Part No. HT/HS/HM/HF/CL Height 750 mm 14024 HT/HS/HM/HF/CL HT/HS/HM/HF/CL HT/HS/HM/HF/CL 250 mm gooseneck arm 500 mm gooseneck arm 700 mm gooseneck arm 15540 15550 15560 HS/HM For installation in tight spaces 12917 ∅ 50 750 500 28 ››› Panel mount M12x1,75 35 ››› Rectangular base 35 23 45 55 in fo @ s u n nex.s e w w w.s unnex.c om 30 ® Sunnex – Accessories ››› ACCESSORY Fits model Info Part No. ››› Reflector, Standard HT HS HS HS HM HF HF Spot Spot (standard) Superspot Flood Spot Spot Flood (standard) 18069 15128 15127 15123 18003 13820 13821 ››› Reflector, HT/HS 12V/20W - 10o light cone 15124 15126 13071 13072 13073 ››› Dichroic lamp o HT/HS HM/HF HF HF 12V/20W - 38 light cone 12V/35W - 38o light cone 12V/50W - 38o light cone 12V/75W - 38o light cone in fo @ s u n nex.s e w w w.s unnex .com 31 ® Sunnex – Accessories ››› ACCESSORY Fits model Info Part No. ››› Halogen bulb HT/HS 6V/20W 15146 HT/HS HT/HS HT/HS HT/HS HT/HS HM/HF HM/HF HF HF HF HF 12V/5W 12V/10W 12V/20W 24V/10W 24V/20W 12V/35W 24V/35W 12V/50W 12V/75W 24V/50W 24V/75W 15142 15145 15140 15144 15141 13830 13837 13831 13832 13834 13835 CL CL CLB/CLM CLB/CLM 9W/21 – Cool White Dulux S 11W/21 – Cool White Dulux S 18W/12 – Daylight Dulux L 24W/12 – Daylight Dulux L 15881 15882 18022 18023 ››› Light tube in fo @ s u n nex.s e w w w.s unnex.c om 32 ® Sunnex – Accessories ››› ACCESSORY Fits model Info Part No. ››› Light tube CLB/CLM CLB/CLM CLB/CLM CLB/CLM CLB/CLM 36W/12 – Daylight Dulux L 24W/21 – Cool White Dulux F 36W/21 – Cool White Dulux F 24W/21 – Cool White Dulux L 36W/21 – Cool White Dulux L 18024 18025 18026 18027 18028 ››› Transformer HT/HS/HM/HF HT/HS/HM/HF HT/HS/HM/HF HT/HS/HM/HF 230V/12V - Max. 75W, IP23 230V/24V - Max. 75W, IP23 230V/12V - Max. 300W, IP44 230V/24V - Max. 300W, IP44 12030 12035 14054 14059 ››› Transformer, ››› Plug-in HT/HS/HM HT/HS/HM HF 220V/12V - Max 20W, IP40 220V/24V - Max 20W, IP40 230V/12V - Max 50W, IP20 14051 14056 18673 in fo @ s u n nex.s e w w w.s unnex .com 33 ® Sunnex – Accessories ››› ACCESSORY Fits model Info Part No. ››› Lens/Glass HT Frosted (standard) 18009 HT HS HS HS HS HM HM HF HF CL CL Clear Clear (standard) Frosted Opaque Red Clear (standard) Frosted Clear (standard) Frosted 200 mm lamp head, 9W 270 mm lamp head, 11W 18007 15402 15112 15113 15114 18004 18005 13825 13826 15861 15862 in fo @ s u n nex.s e w w w.s unnex.c om 34 Sunnex Inhouse. Printed by Alfa Nermans Grafiska, Sweden. Local dealer sticker space: ® Sunnex Equipment AB Box 8064 SE-163 08 Spånga Sweden Tel: +46 854 680 230 Fax: +46 854 680 259 E-mail: info@sunnex.se Website: www.sunnex.com Sunnex Equipment AB Box 555 SE-686 28 Sunne Sweden Tel: +46 565 177 00 Fax: +46 565 104 00 E-mail: info@sunnex.se Website: www.sunnex.com Sunnex GmbH Ricarda-Huch-Str. 2 D-14480 Potsdam Germany Tel: +49 331 600 77 27 Fax: +49 331 600 77 63 E-mail: info@sunnex.de Website: www.sunnex.de Sunnex Equipement Sarl Z.I. Les Milles B.P. 154 000 13794 Aix en Provence, Cedex 3 France Tel: +33 442 39 78 96 Fax: +33 442 39 78 77 E-mail: sunnex@sunnex.fr Website: www.sunnex.fr Sunnex Inc. 3 Huron Drive, Natick MA 01760-1314 USA Tel: +1 800 445 7869 Fax: +1 508 651 0099 E-mail: sales@sunnex.com Website: www.sunnex.com