Installation Instructions
81mm
2
3000042441
0513
1
English
Read the instructions carefully before installation and commissioning!
Leave the instructions for users/
customers for future reference!
Our continually updated product documentation can be accessed
at www.erco.com/download.
General safety information
Warning! Risk of electrocution!
Before carrying out maintenance
and installation on the luminaire, disconnect from the mains supply and
ensure that all power is switched off.
- Do not operate luminaires with
da­maged or missing protective covers.
- Do not open luminaire head. If
damaged, the entire luminaire must be
re­t urned to the factory.
- When installing, always observe the
national installation and accident prevention regulations.
Intended use
- The luminaire is suitable for outdoor
use.
- The luminaire is approved for standing
installation only.
Choosing the mounting location
Luminaires with LED modules must be
positioned so as to avoid operation in
direct sunlight or near other sources of
heat. High ambient temperatures reduce
the life and efficiency of the control gear
or LED module.
Electrical installation
To avoid any damage to the electronic
control gear on a 3-circuit installation,
the neutral conductor of electronic
control gear must never be interrupted.
Over-voltage protection
To protect electronic components from
overload, e.g. when switching inductive
loads, separate excess voltage protection
devices can be used (e.g. ERCO 83819),
connected in parallel on the input side.
Notes on corrosion protection
Ensure that the powder coating is
not damaged during installation or
maintenance work. Any damage, which
becomes wet, can result in corrosion
occurring. In aggressive environments,
the installation and maintenance of
all parts will require the appropriate
protective measures. Chemicals damage
the corrosion protection.
Installation
The bollard luminaire may be mounted
on a concrete base, the ground socket
33974 or the concrete anchor 33981.
Mounting on concrete base
1. Remove the base plate from the lumi-
naire and use it as a drilling template.
2. Place the base plate over the unterground cable. Only use suitable material
for mounting, e.g. stud bolt M10.
Caution! Always comply with the standards and regulations in place for the
mounting location when selecting the
mounting parts.
3. Use the supplied washer. (Fig. 3)
Mounting on ground socket or concrete anchor
1. Remove the base plate from the luminaire and place over the cable.
2. Screw the base plate onto the ground
socket or concrete anchor. Use the supplied washers and cylinder head screws
(included with the ground socket).
(Fig. 3)
Note for concrete anchor:
Follow the concrete anchor instructions
(3000028581).
Electrical connection
Always allow for the diameter of the
underground cable when making the
electrical connection.
∅ 14-20mm
1. Open the grommet and insert the
cable. (Fig. 4)
Note: The second grommet can be used
for through-wiring.
2. Make the electric connection.
∅ 5-14mm
Warning! Risk of electric shock!
The existing grommets are unsuit­
able for cables with a diameter < 14mm.
When using these cables, protection
mode IP65 is no longer guaranteed.
Water may penetrate the terminal compartment.
1. Fit the supplied screw connections to
the top of the terminal compartment.
(Fig. 5)
Note: A further M16 screw connection
is required for through-wiring (not
supplied).
2. Make the electric connection.
Operating instructions for LED luminaires
Replacement of LED modules
If an LED module fails, the entire luminaire must be returned to the factory. For
operational safety reasons, LED modules
must be replaced at the factory.
Flashing of the LED module
It is normal for the LED module to flicker
when switching on and off.
Dimming
The luminaire can be dimmed using a
suitable dimmer (leading edge).
Leading-edge dimmers
Follow the manufacturer’s installation
instructions. For some products, the
luminaire or dimmer can only be switched on in the upper dimming range.
Before installation and connection,
check luminaire, control gear and dimmer combination for proper functioning
of the dimmer, especially when using
3000042441
2
universal dimmers.
The use of dimmers which are unsuitable for LED drivers can damage the
luminaire, control gear and/or the
dimmer.
No responsibility is accepted for the
use of dimmers that are unsuitable for
the luminaire.
Cleaning
Before cleaning, disconnect from
mains supply and allow luminaire
to cool!
- Regular cleaning is essential. The
required intervals and methods depend
on the mounting location, the mounting
situation and the ambient conditions.
Outside cleaning of the luminaire
Clean with a damp, soft cloth. Take care
not to damage the powder-coating.
Cleaning the plastic
Clean with a damp, soft cloth and a
standard pH neutral, alcohol-free, nonabrasive cleaning agent.
Disposal
In accordance with EU Directive
WEEE (Waste Electrical and Electronic Equipment), luminaires must not
be disposed of with other household
waste. At the end of their life, luminaires must be taken to the appropriate
local facility available for the disposal
or recycling of electronic products.
3000042441
3
Download