Hazardous Area (ATEX)
FP6 Siren
Features
Rated for Category 1 use (formerly Zone 1 & 2)
Overall siren standard -
Non electrical parts standard -
Increase temperature specification unit available (T5)
High output siren sound (135dB)
Rugged weatherproof construction
Overview
Applications
The FP6 is a flameproof version of Klaxon's wide area siren,
providing effective signalling over large distances.
Exd II 2 G IIC T4
EExc IIC T1..T6 X
Evacuation alarm; fire alarm; toxic gas release;
COMAH alarm; general purpose alarm
Utilising a traditional siren sound, it provides a recognisable
alarm and is often used for critical alarms such as toxic gas
release and disaster warning.
Certified to EExd llC T4, the FP6 is manufactured from cast
aluminium and will give a very long life when mounted
outdoors. Powered by a 3 phase motor it is designed for
roof or pole mounting.
Using appropriate control equipment the siren can
produce two distinct tones for different types of alarm.
Fire
Security
Industrial
Part No.
18-980318
Railway/Marine
Hazardous Area
Public Warning
Colours
Audibility at 1m
Tones
Voltage
Current
Grey/Red
Up to 135dB (A)
2
400V 3 phase
4.5A
IP Rating: IP55 Rating: Continuous on constant tone Motor Power: 2.2kW Frequency: 475Hz
Temp: -20ºC to +40ºC
Construction: Cast Aluminium Cable Entries: 1 Weight: 68kg
Klaxon Signals Limited
Wrigley Street, Oldham
Lancashire, UK OL4 1HW
T. +44 (0)161 287 5555
F. +44 (0)161 287 5511
E. sales@klaxonsignals.com
w. www.klaxonsignals.com
8
Operating
part 3.qxp:part 3.qxd
9/10/07
10:44
Page 9
Hazardous Area (ATEX)
FP10 Siren
Features
ATEX approved for Zone 1 and Zone 2 use -
Overall siren standard -
Non electrical parts standard -
Increase temperature specification unit available (T5)
High output siren sound (140dB)
Rugged weatherproof construction
Overview
Applications
The FP10 is a flameproof version of Klaxon's wide area siren,
providing effective signalling over large distances.
II 2 G
Exd II 2 G IIC T4
EExc IIC T1..T6 X
Evacuation alarm; fire alarm; toxic gas release;
COMAH alarm; general purpose alarm
Utilising a traditional siren sound, it provides a recognisable
alarm and is often used for critical alarms such as toxic gas
release and disaster warning.
Certified to EExd llC T4, the FP10 is manufactured from cast
aluminium and will give a very long life when mounted
outdoors. Powered by a 3 phase motor it is designed for
roof or pole mounting.
Using appropriate control equipment the siren can
produce two distinct tones for different types of alarm.
Fire
Security
Industrial
Part No.
18-980334
Railway/Marine
Hazardous Area
Public Warning
Colours
Audibility at 1m
Tones
Voltage
Current
Grey/Red
Up to 140dB (A)
2
400V 3 phase
13A
IP Rating: IP55 Rating: Continuous on constant tone Motor Power: 5.5kW Frequency: 470Hz
Temp: -20ºC to +40ºC
Construction: Cast Aluminium Cable Entries: 1 Weight: 80kg
Klaxon Signals Limited
Wrigley Street, Oldham
Lancashire, UK OL4 1HW
T. +44 (0)161 287 5555
F. +44 (0)161 287 5511
E. sales@klaxonsignals.com
w. www.klaxonsignals.com
9
Operating
FP2C Siren
The FP2C is a powerful motor driven siren for use in hazardous
area applications and harsh environmental conditions. It
produces a siren sound which is easily recognisable and is
often used for critical alarms such as toxic gas release.
Manufactured from cast aluminium, it is designed for a long
life in outdoor locations and is suitable for signalling on
chemical and petrochemical installations.
Certified to ATEX II 2 G EExd IIB T6, it is suitable for Category
1 use.
Applications - Evacuation alarm; fire alarm; toxic gas
release; general purpose alarm
Using appropriate control equipment, the siren can produce
two distinct tones.
Features
■
■
■
■
■
Rated for Category 2 use (formerly Zone 1 & 2)
ATEX approved
II 2G EExd IIB T6
High output siren sound (123dB)
Rugged weatherproof construction
Fire
Security
Industrial
Railway/Marine
Hazardous Area
Public Warning
Specifications
Part No.
Colours
Audibility (tone) at
1m (typical)
Tones
(Up to)
Voltage
(50/60Hz)
Current
(tone dependent)
18-980361
Red
Up to 123 dB (A)
2
110V AC
3.7A
18-980006
Red
Up to 123 dB (A)
2
230V AC
2.3A
IP Rating: IP55 Rating: 20 Minute Thermal Cut-Out Frequency: 900Hz
Construction: Cast Aluminium Cable Entries: 1 Weight: 10kg
Operating Temp: -20ºC to +40ºC
Visit us at: www.klaxsonsignals.com
49
II 2 GD Ex d IIC Ex tD A21 - Sirene elettromeccaniche antideflagranti
II 2 GD Ex d IIC Ex tD A21 - Explosion-proof electric motor sirens
V 12-24-110-240 (±10%)
50/60 Hz
IP 65
66
IP 66
ø 1/2” NPT
ø 3/4” ISO 7/1**
°C -50 +50
ISSeP 08 ATEX 004 X
V
On: 1 min. Off: 10 min.
12
24
110
T6
240
A
3
1.6
0.45
0.3
dB(A)1m
100
100
100
100
Hz
1500
1500
1600
1600
ETS30/100DB
ETS30100DB12DA
ETS30100DB24DA
62234
62235
ETS30100DB110DA
ETS30100DB240DA
INERIS 02 ATEX 0001
V
Linea antideflagrante Atex . Explosion-proof Atex range
ETS60/109DB**
12
24
110
15
8.5
2
1
dB(A)1m
109
109
109
109
Hz
1150
1250
1300
1300
62233
62231
ETS60/114DB**
ETS60109DB110DA
ETS60109DB240DA
12
24
110
12
6.3
2
1
dB(A)1m
114
114
114
114
Hz
650
650
650
650
62225
62229
Kg. 3,20
62227
62228
Kg. 3,45
T6
A
ETS60114DB12DA
ETS60114DB24DA
62232
62230
240
INERIS 02 ATEX 0001
V
Kg. 1,45
T6
A
ETS60109DB12DA
ETS60109DB24DA
62236
62237
240
ETS60114DB110DA
ETS60114DB240DA
II 2 GD Ex d IIC Ex tD A21 - Sirene elettroniche antideflagranti
II 2 GD Ex d IIC Ex tD A21 - Explosion-proof electronic sirens
V 12/24-110-240 (±10%)
50/60 Hz
°C -50 +50
INERIS 02 ATEX 0074
V
12÷24
V
mA
dB(A)1m
865
On
IP 65
ø 3/4” ISO 7/1
T6
-
-
110
240
45
30
Min. 91 - Max. 109
ETH12 MD
ETH12MD1224DA
ETH12MD110A
ISSeP 01 ATEX 014
V
12÷24
V
mA
57994
57997
ETH12MD240A
57996
ETH20MD240A
57995
Kg. 1,40
T6
240
550
25
dB(A)1m Min. 101 - Max. 112
ETH20 MD
304
ETH20MD1224DA
57998
Kg. 3,35