Product Specification TelcoFlex™ Central Office Power Cables • Compliant to Telcordia GR-347-CORE UL listed and CSA certified • Features TelcoHyde™ thermoset flexible rubber insulation • Non-halogen, RoHS Compliant • LS (Limited-Smoke) rated • Non-silicone and lead-free • Braided and non-braided constructions • Flexible and durable TYPE TelcoFlex™ II Central Office Power Wire and Cable Class I Flexible Strand Without Braid Low Smoke, Non-Halogenated Insulation, Lead-Free and Silicone-Free, UL Central Office Power Cable 105°C Dry, 60°C Wet, UL Listed RHH/LS FT4 and VW-1, 90°C Dry, 60°C Wet, 600 Volts, Sizes 1/0 AWG and larger are UL, “CT USE” rated. CSA AWM I B 105°C 600 Volt FT4-ST1 SCOPE This specification covers the construction requirements for low smoke, non-halogenated, TelcoHyde™ 5221 insulated, power wire and cable, type RHH/LS for use in accordance with the National Electrical Code. The construction of the wire and cable is in accordance with Underwriters’ Laboratories requirements and the requirements of CSA for the FT4 flame tests. CONSTRUCTION Surface Marking: Two sides of the cable shall be printed using an ink of contrasting color and with the following information: “TelcoFlex™ II/KS24194™ L2 NON-HAL (SIZE) AWG (OR KCMIL) 600V. RHH/LS FT4 (UL) OR AWM 3578 VW-1 E18321---A.I.W. CORP.---LL8825 CSA AWM I B 105°C 600V. FT4-ST1 (YEAR) (SEQ. FTG. ON 1 SIDE)”. For sizes 1/0 AWG and larger add “FOR CT USE” before “(UL)” Size: Sizes 8 AWG through 750 KCMIL - Single conductor. Testing: Physical and electrical tests in accordance with UL Standard 44 requirements. Conductors: Class I (modified) bunched (8 and 6 AWG) and rope-bunched (4 AWG and larger) stranded tinned copper conforming to ASTM B-33 and Underwriters’ Laboratories requirements. An opaque mylar tape shall be applied over the conductor to facilitate stripping. Labels: UL tags and labels shall be applied to each reel. Insulation: 90°C rated limited smoke, non-halogen, TelcoHyde™ 5221 conforming to Underwriters’ Laboratories Standard 44 and Telcordia Specification GR-347-CORE, also UL and CSA 105°C AWM rated. The insulation has a limiting oxygen index of 35%. CABLE DATA CONDUCTOR DIAMETER (INCHES) NOMINAL INSULATION INSULATION MIN. AVG. DIAMETER WALL (INCHES) (MILS) MAX. D.C. APPROX. STOCK RES. @ 20°C WEIGHT COLOR* (OHMS/M FT.) LBS./M FT. PART NUMBER SIZE AWG OR KCMIL STRANDING 39747 39748 39749 39750 8 6 4 2 41/.0201" 65/.0201" 105/.0201" 168/.0201" .153 .188 .260 .305 60 60 60 60 .280 .315 .385 .430 .6790 .4360 .2740 .1720 Gray Gray Gray Gray 86 120 193 284 39751 39752 39753 1/0 2/0 4/0 266/.0201" 342/.0201" 532/.0201" .392 .455 .577 80 80 80 .560 .620 .745 .1090 .0868 .0546 Gray Gray Gray 457 570 844 39754 39755 39756 350 500 750 888/.0201" 1221/.0201" 1850/.0201" .760 .890 1.094 95 95 110 .960 1.090 1.325 .0334 .0234 .0157 Gray Gray Gray 1336 1850 2740 *Also available in black, blue, green, red and with black tracer; consult factory. AMERICAN INSULATED WIRE CORP., 260 Forbes Blvd., Mansfield, MA 02048 • 1-800-366-2492 • Fax 1-508-964-1192 TYPE TelcoFlex™ III Central Office Power Wire and Cable Class B Stranded With Braid Low Smoke, Non-Halogenated Insulation With Cotton Braid, Lead-Free and Silicone-Free, UL Listed RHH/LS FT4 and VW-1, 90°C Dry, 60°C Wet - 600 Volts UL Listed “For CT Use” (Sizes 1/0 AWG and Larger) CSA AWM I B 105°C, 600 Volt, FT4 SCOPE This specification covers the construction requirements for low smoke, non-halogenated, TelcoHyde™ 5221 insulated, cotton braided power wire and cable, type RHH/LS for use in accordance with the National Electrical Code. The construction of the wire and cable is in accordance with Underwriters’ Laboratories requirements and the requirements of CSA for the FT4 flame tests. Sizes 1/0 AWG and larger are UL “CT USE” rated. Finish: A moisture resistant, flame retardant saturant and a colored finisher is applied to the braid. CONSTRUCTION Sizes: 14 AWG through 750 KCMIL - Single conductor Conductors: Class B stranded tinned copper conforming to ASTM B-33 and B-8 and Underwriters’ Laboratories requirements. An opaque mylar tape shall be applied over the conductor to facilitate stripping. Insulation: 90°C rated limited smoke, non-halogen, TelcoHyde™ 5221 conforming to Underwriters’ Laboratories Standard 44 and Telcordia Specification GR-347-CORE, also CSA 105°C AWM rated. The insulation has a limiting oxygen index of 35%. Covering: On all sizes a natural cotton braid conforming to UL requirements is applied overall. A section of completed cable has a limiting oxygen index of 35%. Surface Marking: Two sides of the cable shall be printed using an ink of contrasting color and with the following information: “TelcoFlex™ III/KS24194™ L3 NON-HAL (SIZE) AWG (OR KCMIL) 600V. RHH/LS FT4 (UL) OR AWM 3578 VW-1 E18321---A.I.W. CORP.---LL8825 CSA AWM I B 105°C 600V. FT4 (YEAR) (SEQ. FTG. ON 1 SIDE)”. For sizes 1/0 AWG and larger add “FOR CT USE” before “(UL)” Testing: Physical and electrical tests in accordance with UL Standard 44 requirements. Labels: UL tags and labels shall be applied to each reel. Separator: On sizes 6 AWG and larger a 1 mil clear mylar tape shall be applied over the insulation. CABLE DATA NOMINAL INSUL. DIAMETER (INCHES) STOCK COLOR* .200 .220 .250 2.730 1.720 1.080 Gray Gray Gray 31 41 59 .270 .305 .350 .410 .320 .355 .400 .460 0.678 0.427 0.269 0.169 Gray Gray Gray Gray 92 130 190 282 80 80 80 .530 .575 .680 .585 .630 .735 0.106 0.084 0.052 Gray Gray Gray 443 538 812 95 95 110 .860 .990 1.200 .915 1.045 1.260 0.032 0.022 0.0148 Gray Gray Gray 1313 1822 2692 SIZE AWG OR KCMIL 39757 39758 39759 14 12 10 7/.0242” 7/.0305” 7/.0385” 45 45 45 .165 .185 .210 39760 39761 39762 39763 8 6 4 2 7/.0486" 7/.0612" 7/.0772" 7/.0974" 60 60 60 60 39764 39765 39766 1/0 2/0 4/0 19/.0745" 19/.0837" 19/.1055" 39767 39768 39769 350 500 750 37/.0973" 37/.1162" 61/.1109" STRANDING NOMINAL OVERALL DIAMETER (INCHES) MAX. D.C. RES. @ 20°C (OHMS/M FT.) INSULATION MIN. AVG. WALL (MILS) PART NUMBER APPROX. WEIGHT LBS./M FT. *Also available in black, blue, green, red and with black tracer; consult factory. AMERICAN INSULATED WIRE CORP., 260 Forbes Blvd., Mansfield, MA 02048 • 1-800-366-2492 • Fax 1-508-964-1192 TYPE TelcoFlex™ IV Central Office Power Wire and Cable Class I Flexible Strand With Braid Low Smoke, Non-Halogenated Insulation With Cotton Braid, Lead-Free and Silicone-Free, UL Listed RHH/LS FT4 and VW-1, 90°C Dry, 60°C Wet, 600 Volts, UL Listed “For CT USE” (1/0 AWG and Larger), CSA AWM I B 105°C, 600 Volts, FT4 SCOPE This specification covers the construction requirements for low smoke, non-halogenated, TelcoHyde™ 5221 insulated, cotton braided power wire and cable, type RHH/LS for use in accordance with the National Electrical Code. The construction of the wire and cable is in accordance with Underwriters’ Laboratories requirements and the requirements of CSA for the FT4 flame tests. Sizes 1/0 AWG and larger are UL “CT USE” rated. CONSTRUCTION Sizes: 8 AWG through 750 KCMIL - Single conductor Conductors: Class I (modified) bunched (8 and 6 AWG) and rope-bunched (4 AWG and larger) stranded tinned copper conforming to ASTM B-33 and Underwriters’ Laboratories requirements. An opaque mylar tape shall be applied over the conductor to facilitate stripping. Insulation: 90°C rated limited smoke, non-halogen, TelcoHyde™ 5221 conforming to Underwriters’ Laboratories Standard 44 and Telcordia Specification GR-347-CORE, also CSA 105°C AWM rated. The insulation has a limiting oxygen index of 35%. Covering: On all sizes, a natural cotton braid conforming to UL requirements is applied overall. A section of completed cable has a limiting oxygen index of 35%. Finish: A moisture resistant, fire retardant saturant and a colored finisher is applied to the braid. Surface Marking: Two sides of the cable shall be printed using an ink of contrasting color and with the following information: “TelcoFlex™ IV/KS24194™ L4 NON-HAL (SIZE) AWG (OR KCMIL) 600V. RHH/LS FT4 (UL) OR AWM 3578 VW-1 E18321---A.I.W. CORP.---LL8825 CSA AWM I B 105°C 600V. FT4 (YEAR) (SEQ. FTG. ON 1 SIDE)”. For sizes 1/0 AWG and larger add “FOR CT USE” before “(UL)” Testing: Physical and electrical tests in accordance with UL Standard 44 requirements. Labels: UL tags and labels shall be applied to each reel. Separator: On sizes 6 AWG and larger, a 1 mil clear mylar tape shall be applied over the insulation. CABLE DATA PART SIZE AWG STRANDING NUMBER OR KCMIL NOMINAL NOMINAL INSUL. CONDUCTOR INSUL. MIN. AVG. OUTSIDE DIAMETER DIAMETER DIAMETER WALL (INCHES) (INCHES) (INCHES) (MILS) MAX. D.C. APPROX. STOCK RES. @ 20°C WEIGHT COLOR* (OHMS/M FT.) LBS./M FT. 39770 39771 39772 39773 8 6 4 2 41/.0201" 65/.0201" 105/.0201" 168/.0201" .153 .188 .260 .305 60 60 60 60 .280 .315 .385 .430 .330 .365 .435 .480 .6790 .4360 .2740 .1720 Gray Gray Gray Gray 86 120 193 284 39774 39775 39776 1/0 2/0 4/0 266/.0201" 342/.0201" 532/.0201" .392 .455 .577 80 80 80 .560 .620 .745 .615 .675 .800 .1090 .0868 .0546 Gray Gray Gray 479 593 882 39777 39778 39779 350 500 750 888/.0201" 1221/.0201" 1850/.0201" .760 .890 1.094 95 95 110 .960 1.090 1.325 1.015 1.145 1.380 .0334 .0234 .0157 Gray Gray Gray 1373 1906 2792 *Also available in black, blue, green, red and with black tracer; consult factory. AMERICAN INSULATED WIRE CORP., 260 Forbes Blvd., Mansfield, MA 02048 • 1-800-366-2492 • Fax 1-508-964-1192 SSTELCOFLEX-05/01