ASCO 7000 Series IEC Medium Voltage Power Transfer Switches Where Supply and Demand Connect ASCO 7000 Series IEC Medium Voltage Power Transfer Switches Power Continuity for: • Healthcare Facilities • Telecom Exchanges • Industrial Complexes • Data Centers • Chemical Industry • Refineries • Waste Water Treatment • Retail Business Centers • Other Mission Critical Facilities The availability, quality and reliability of electrical power can ASCO products can transform what could be a major impact life, safety, productivity and financial success. catastrophe into complete assurance. ASCO Power Technologies provides solutions to assure the With a variety of configurations, options and transfer modes continuity of power, from the design stage to installation, including open, delayed, and closed, ASCO 7000 Series start-up and beyond: complete coverage for continuous Medium Voltage Power Transfer Switches deliver per power. specifications and leverage industry leading switchgear per the IEC 62271-200 standard for metal-enclosed switchgear and controlgear. 1 Engineered For Quality Factory Testing On Every Assembly The Innovation of ASCO Medium Voltage Power Transfer Switches ASCO 7000 SERIES IEC Medium Voltage Power Transfer Switches IEC Class: 7.2kV, 12kV and 24kV; Up to 2500 Ampere Voltage Class Rated Current (Amp) 630 1250 7.2kV or 12kV 2000 Remarks Width * Depth Height 2400 1350 2200 Same For Fixed or Draw Out PT 2400 1970 2200 Fixed PT Draw Out PT 2800 1350 2200 2400 1970 2200 Fixed PT 2800 1350 2200 Draw Out PT 1250 3000 1810 2855 2000 3000 2448 2855 2500 24kV Med Voltage Transfer Switch Dimensions (mm) Fixed PT only * Width is for gear without side panels for integration into larger switchgear lineups. Side panels for standalone installation add a total of 70mm to the width shown above. All equipment ships with removable side panels on the 2 end sections. An ASCO 7000 Series microprocessor-based controller The chart below provides an overview of the Short Time and (Transfer Control Center) manages breaker operation to Peak Withstand ratings currently available. transfer between critical loads and between power sources. Contact your local representative for availability of other Comprising voltage classes of 7.2 kV, 12 kV and 24kV per options. IEC standards, the Medium Voltage Transfer Switch may be equipped with protective relays, power metering, and Voltage Class Rated Current Ethernet communications to meet installation requirements. 630A Additionally, custom engineered solutions per specifications 1250A may also be accommodated. Switch mode options include 2000A open transition, closed transition, and delayed transition. 7.2kV or 12kV industry leading breaker technology and are approved with 2000A 63 kA 31.5kA 80kA 25kA 63kA 31.5kA 80kA 2500A internal arc classification IAC A FLR, loss of service continuity requirements regarding personal safety. 25 kA 630A 1250A suitable for universal installation, meeting the highest Peak Withstand Current 2500A All ASCO 7000 Medium Voltage Transfer Switches utilize category LSC 2B and partition class PM. This makes them Short Time Withstand Current (4 sec) 1250A 24kV 2000A 1250A 2000A 2 ASCO 7000 SERIES Medium Voltage Power Transfer Switches (IEC) ASCO Medium Voltage Power Transfer Switches are rated up to 24kV, with current capacities of 630 through 2500 amperes. The Medium Voltage Automatic Transfer Switch basic configuration comprises three modular vertical sections. Key components and features include: ¾ ASCO 7000 Series Transfer Control Center For Open Transition, Closed Transition, Or Delayed Transition Operation ¾ Use of maintenance-free vacuum circuit-breakers with optional Protective Relaying • One (1) Normal Source VCB • One (1) Emergency Source VCB ¾ Two (2) Normal Source Fused Voltage Transformers (V/V) ¾ Two (2) Emergency Source Fused Voltage Transformers (V/V) ¾ Confinement of an internal arc to the respective compartment up to 40 kA (31.5kA for 24kV) ¾ Standard Accessories: • 1G External 24VDC auxiliary power connections • 18B 2 pole double-throw contacts that operate when emergency source voltage is present • 18G 2 pole double-throw contacts that operate when normal source voltage is present • 30E Load Shed circuit ASCO 7000 SERIES IEC Medium Voltage Power Transfer Switch (Load Section Shown On Right) • 31Z Selective Load Disconnect circuit • Strip Heaters For Temperature and Humidity Control • Maintenance Lighting In Control and Rear Cable Compartments ¾ Optional Protective Relay ¾ Optional Power Metering and Ethernet communications ¾ Integration with ASCO’s Critical Power Management System for advanced monitoring and control of your facilities critical power systems 3 At the Crossroads of Performance and Simplicity Transfer Switch Controller Medium Voltage Transfer Switch Specifications The ASCO 7000 Series Transfer Control Center provides refined and proven transfer control for low and medium voltage switches, leveraging almost a century of power transfer innovation and application experience. Voltage Nominal System Voltage Ampacity Rating 7.2 kV 3.3kV 6kV 12 kV 6.6kV 10kV 11kV 630A,1250A,2000A,2500A Number of Sections Yes Circuit Breakers Arc Resistance IAC A FLR Bottom Cable Entry Yes ASCO 7000 Series Medium Voltage Power Switches use vacuum circuit breakers for superior reliability and maintainability. Each circuit breaker is listed according to IEC 62271-100 and is suitable for all indoor switching duties. Breakers are designed for maintenance-free operation under normal climatic conditions and the maximum permissible number of operating cycles. Draw Out Circuit Breakers Yes Automatic Shutters Yes Grounded Barriers Yes Powder Coated with Epoxy Resins Yes Enclosure Rating IP4X Normal Source and Emergency Source circuit breakers are interchangeable due to identical ratings and configuration. Stored energy mechanisms include electric motor charging and a manual charging handle. Breakers are designed and manufactured to assure safe withdrawal for inspection and to facilitate maintenance. Arc Safety Overview of Standards RAL 7035 Protective Relays Optional Ethernet/Serial Communications Optional Power Metering Optional Instrument transformers include Current Transformers (CT) and Voltage Transformers (VT, a.k.a. Potential Transformers - PT) to measure circuit voltage and current. Controlgear Assembly IEC Standard GB Standard IEC 62 271-1 GB/T 11022 IEC 62 271-200 GB 3906 Circuit-breaker IEC 62 271-100 GB 1984 Disconnector and Earthing Switch IEC 62 271-102 GB 1985 High-voltage alternating current switch-fuse combinations IEC 62 271-105 GB 16926 Fuse IEC 60 282-1 GB 15166.2 Voltage Detection Device IEC 61 243-5 - IEC 60 529 GB/T 4208 Degree of Protection Yes Standard Color Instrument Transformers Internal arc classified switchgear according to IAC AFLR; front, lateral and rear accessibility for all short circuit currents and an arc duration of 1s. Switchgear 22kV 1250A,2000A 3 IEC 62271-200 Integrated Mimic Diagram 24kV 20kV Insulation IEC 60 071-1 GB 311.1 Current Transformer IEC 60 044-1 GB 1208 Voltage Transformer IEC 60 044-2 GB 1207 Installation IEC 61 936-1 GB 50254-GB 50259 The controlgear assembly is air-insulated, type-tested, metalenclosed and metal-clad medium-voltage switchgear for indoor installation complying with IEC 62271-200. The panel consists of three compartments: bus bar compartment, connection compartment, and low-voltage compartment. The controlgear has loss of service continuity category LSC 2B which allows access to compartments while other adjacent compartments remain in operation. The complete enclosure and the partitions between the individual compartments and covers are metallic and earthed. These features guarantee the highest possible service continuity category. 4 Transition Options and Control Modes Open Transition Transfer Switching Closed Transition Transfer Switching ASCO Open Transition Transfer Switches feature non-overlapping breaker operation, assuring that electrical power sources remain isolated and effectively interrupting the flow of power. The switch transfers in a ‘break before make’ mode. ASCO Closed Transition Transfer Switches feature overlapping breaker operation, permitting the transfer of electrical loads while maintaining electrical continuity. The switch transfers in a ‘make before break’ mode if all synchronization parameters for both sources are within acceptable ranges. Control logic in the ASCO Series 7000 Transfer Control Center monitors source conditions and automatically determines if the transfer should be open (conventional non-overlap mode) or closed transition or less. Delayed Transition Transfer Switching ASCO Delayed Transition Transfer Switches provide a prescribed disconnect time for load transfers between power sources. The adjustable period of delay allows stored energy loads to dissipate power. Stored energy loads may include motors and drives, rectifier banks, power correction and filtration devices, and load management applications. Interlocking prevents direct connection of both sources to the load concurrently. Closed transition transfers occur within prescribed synchronization parameters passively, without control of the engine generator set operation. Therefore, no additional control wiring is required between the ATS and engine generator set governor or voltage regulator. Prescribed overlap time in a closed transition transfer is typically 100 milliseconds or less. Automatic and Manual Control Modes The mode selector switch allows the user to select between automatic and manual control modes. Automatic control options include open, delayed and closed transition. Electrically interlocked manual controls on the front door permit safe, usersupervised operation in non-automatic mode. Breaker Control Switch Mode Selector Switch Allows the operator to trip the breaker in any control mode The mode selector switch allows the user to select between automatic and manual control modes. Every circuit breaker includes, on the front door of its compartment, a breaker control switch for manually opening and closing the circuit breaker when the system is in manual mode. Electrical interlocks prevent simultaneous closure of Normal and Emergency source breakers. Manual trip of Normal and Emergency source breakers functions in both automatic and manual modes. Allows the operator to close the breaker in manual mode with interlock protection “Trip”, “Close”, and “NAT/NAC” positions. Indicator LED NAC (Normal After Close) Red NAT (Normal After Trip) Green 5 The ASCO 7000 Series Medium Voltage Power Transfer Switch includes advanced components such as the ASCO 7000 Series Transfer Control Center and optional protective relays. Options and Specified Components Protective Relays Protective relays address circuit protection and coordination requirements not typically included in the scope of a transfer switch. Examples of circuit protection include: • Instantaneous Overcurrent • AC Inverse Time Overcurrent • Directional Power An additional relay device, known as a Lockout Relay, assures fault acknowledgement by locking a breaker open after a fault trip. The Lockout Relay, once a fault trip occurs, requires manual intervention to reset the trip condition and allow the breaker to resume automatic control. In addition to adjustable protection parameters, protective relays additionally facilitate the implementation of complex coordination requirements by allowing sophisticated trip curve tuning. The ASCO 7000 Series IEC Medium Voltage Power Transfer Switch includes standardized selections of protective relay options. Customer requirements of additional protective relaying may also be specified. Additional capabilities include web servers, gateways and managed networks. The A SCO Digital Power Meter provides additional communication, protection and metering capabilities for normal and emergency sourcing as well as loads, particularly useful for measuring metering total power, generator and utility, delivered to the load. Power Monitoring Power monitoring systems, commonly employed at many facilities with sophisticated power distribution, provide a focal point for systematic alarming, reports, control, diagnostic and operational information. As these systems become more sophisticated, providing analytical services such as operational evaluations and service scheduling, the importance of connectivity escalates. Instrumentation, Control & Metering With over a century of innovative firsts, ASCO excels in digital instrumentation, controls and metering for electrical equipment. Specified items can include: Communication and Connectivity Capabilities • PowerQuest Critical Power Management System (CPMS) ASCO offers flexible and sophisticated communication options including a variety of technologies and protocols to meet connectivity requirements. Examples of peer and client/server communication options include RS-485 and Ethernet connectivity and Modbus ™ protocols. • Digital metering: current, voltage, power, power factor, frequency • Discrete indicator lights for status and control information at a glance 6 ASCO 7000 Series Transfer Control Center The ASCO 7000 Series Transfer Control Center provides power transfer control to low voltage power transfer switches up to 4000 amperes and medium voltage power transfer switches up to 2500 amperes. Leveraging ASCO’s history and experience, the controller combines state-of-the-art microprocessor technology, superior noise immunity and advanced data computation and evaluation algorithms. It represents the standard for digital transfer switch technology to which all others are measured, processing voltage, current and frequency data, excelling in control logic, and reporting status and diagnostic information with real-time urgency. ASCO 7000 SERIES Transfer Control Center - Surge Specifications Emission Standard - Group 1, Class A EN 55011 Generic Immunity Standard EN 50082-2 Electrostatic Discharge (ESD) Immunity EN 61000-4-2 Radiated Electromagnetic Field Immunity ENV 50140 Radiated RF Electromagnetic Field Immunity EN 61000-4-3 Electrical Fast Transient (EFT) Immunity EN 61000-4-4 Surge Transient Immunity EN 61000-4-5 Conducted Radio-Frequency Field Immunity EN 61000-4-6 Voltage Dips, Interruptions and Variations Immunity EN 61000-4-11 ASCO 7000 Series Microprocessor Controller 7 ASCO 7000 Series Transfer Control Center - Features Digital microprocessor Touch pad programming of features and settings without the need for meters or variable power supplies On-board diagnostics provide status panel, integrated display and communication interface with system status and performance information Displays and counts down active time functions Selectable multilingual display including English, German, Portuguese, Spanish, French and others upon request Password protection to prevent unauthorized tampering with settings Remote monitoring and control with ASCO PowerQuest communications products Historical event log Statistical system monitoring information available via integrated display and communication interface Voltage and Frequency Sensing Time Delays • Under- and over-voltage settings on normal and emergency sources. • Engine start time delay – adjustable from 0 to 6 seconds – delays engine starting signal to override momentary normal source loss. • Under- and over-frequency settings on normal and emergency. • Transfer to emergency time delay – adjustable from 0 to 60 minutes. • True RMS voltage sensing with +/- 1% accuracy. • Frequency sensing with +/- 0.2% accuracy. • Emergency source stabilization time delay – adjustable from 0 to 6 seconds – ignores momentary transients during initial generator set loading. • Phase sequence sensing for phase sensitive loads. • Voltage unbalance detection between phases. • Retransfer to normal – time delay with two settings: o Power failure mode – adjustable from 0 to 60 m o Test mode – adjustable from 0 to 10 h Status and Control Features • Output contact (N/O or N/C) for engine-start signals. • Selection between “commit/no-commit” on transfer to emergency after engine start and normal restores before transfer. • Event log displays 99 logged events with time/date stamp, event type and event reason. • Optional output signals for remote indication of normal and emergency source acceptability • Statistical system monitoring data screens which provide: o Total number of transfers. o Number of transfers caused by power source failure. o Total number of days the transfer switch has been in operation. o Total number of hours that the normal and emergency sources have been available. • Unloaded running time delay – adjustable from 0 to 60 minutes – provides engine cool-down time before shutting down the engine. • Pre- and post-transfer signal time delay – adjustable from 0 to 5 minutes – is for selective load disconnect with a programmable bypass on source failures. This signal can be used to drive a customer furnished relay, or accessory 31Z for two (2) sets of double throw contacts rated 10 amperes at 220 volts AC, which is included as standard. • Fully programmable engine exerciser with seven independent routines to exercise the engine generator, with or without loads, on a daily, weekly, bi-weekly or monthly basis. • Closed transition transfer time delays include: o In-synch time delay – adjustable from 0 to 3 s o Failure to synchronize – adjustable from 1 to 5 m o Extended parallel – adjustable from 0.1 to 1.0 s • Delayed transition load disconnect time delay – adjustable from 0 to 5 minutes – disconnects the load for the set period of time between power transfers (normal to emergency, or emergency to normal). 8 ASCO 7000 Series Medium Voltage Transfer Switches ASCO power products are designed to be the world’s most robust, intelligent and advanced power transfer and control system with extensive diagnostic capabilities. The 7000 Series Medium Voltage Transfer Switch is engineered to safely provide continuous power in the widest range of emergency and standby power applications including industrial, commercial and business-critical facilities as well as health care campuses. ASCO 7000 Series Medium Voltage Transfer Switches - Catalog Number A 7 Interrupting Rating(1) Product Series Operation Transition Type Construction Type 7 A Automatic A E B 25kAIC 31.5kAIC 40kAIC 7000 Series A D Blank C D T Open T Closed Delayed Transfer C C 0 Device Type Neutral Code GB/IEC MV 0 Dual CB Transfer Switch None 3 1250 8 (3) Poles Amperes(2) Voltage Controller 3 0630 1250 2000 2500 3 4 6 8 V 2 O 3.3kV 6kV 6.6kV 10kV 11kV 22kV Other (1) 24kV class systems are only available in 25kAIC and 31.5kAIC configurations. (2) 24kV class systems are only available in 1250A and 2000A configurations. (3) When the nominal system voltage is 3.3kV, 6kV or 6.6kV, the rated voltage of the switchgear is 7.2kV; When the nominal system voltage is 10kV or 11kV, the rated voltage of the switchgear is 12kV; When the nominal system voltage is 20kV or 22kV, the rated voltage of the switchgear is 24kV. 9 5 5 Grp5 X L Accessories Enclosures 0 X Z None L Per Acc Number (See table) Per Spec. IP4X ASCO 7000 Series Medium Voltage Transfer Switches- Accessories Standard Accessory Code Accessory Code 1G 18B/18G Description External 24VDC Auxiliary Power Connection Contacts That Operate When Source Voltage Present (18G - Normal; 18B - Emergency) 30E Load Shed Circuit 31Z Selective Load Disconnect Circuit Please list these standard accessory codes in the Catalog Number when ordering. Optional Accessory Code Accessory Code 72EE2 Description ASCO Communications Module 73E Lightning / Surge Protection On Emergency (Source 2) 73N Lightning / Surge Protection On Normal (Source 1) 118RE Protective Relay NR (NSR612F-DS) On Emergency 118RN Protective Relay NR (NSR612F-DS) On Normal 118XE Protective Relay XJ Electric (WGB-871) On Emergency 118XE1 Protective Relay XJ Electric (WGB-681A, with Differential Protection) On Emergency 118XN Protective Relay XJ Electric (WGB-871) On Normal 135L ASCO Power Meter On Load 139C1 CTs On Load (Required With 135L) 139C2 139C3 CTs On Normal & Emergency (Required With 118*N or*E) CTs On Load, Normal, & Emergency (Required If 135L AND 118*N/*E) 139DT PT Drawout Trucks In Breaker Sections (Set of 2) (Not available on 24kV class switchgear) 139GE Grounding Switch On Emergency (Source 2) 139GL Grounding Switch On Load 139GN Grounding Switch On Normal (Source 1) 139V1 Change 220V Breaker Control Voltage to 110V For more accessories, please contact local ASCO representative. Lift Truck and Service Kits Sold Separately Accessory P/N Description K734409-001 CB Lift Truck (for 800mm width switchgear) K734409-002 CB Lift Truck (for 1000mm width switchgear) A38180 Installation and operation tools (including handles and lubricant etc.) 10 Throughout your business cycles, from design to post-installation service and support, ASCO provides unparalleled assistance to navigate through each step of the process and achieve your goals TECHNOLOGY ASCO commercialized the first power transfer switch in 1920. Today, ASCO is the world’s largest manufacturer of worldclass power transfer systems. ASCO innovation delivers more than 100 million kilowatts every day. Reliably. Repeatedly. ASCO innovations over the past century stand as milestones in power transfer technology. ASCO Medium Voltage Power Transfer Switches optimize reliability and total cost of ownership. ASCO integrated systems are the reference point for reliability, configurability and reduced maintenance requirements. Specify the exact medium voltage transfer switch capabilities you need. With so much at stake, protect your facility’s Business-Critical Continuity™, and your reputation. SUPPORT ASCO Support defines collaboration, comprising highly-skilled teams of factory-based and geographically dispersed application engineers and project managers. Properly specifying medium voltage power transfer switches demands a thorough understanding of a range of issues and challenges. A team assigned to your project will work with you every step of the way, from design to commissioning, and post-installation service. It’s our support that separates ASCO from the competition. We will help you develop solutions that reduce installation costs, save time, improve operating efficiency, conserve utility and maintenance costs, and provide complete life cycle management, including upgrades and retrofits. SERVICE ASCO provides service technicians, product specialists and engineers worldwide enable unparalleled assurance. With over 450 Emerson and other factory trained and authorized service representatives, ASCO is sure to be nearby to help you address your design, operational, and service challenges. To select a manufacturer who provides continuous coverage for continuous power, contact your regional ASCO representative or visit our website at: www.EmersonNetworkPower.com/ASCO We are ready serve your needs 24 hours a day, 7 days a week. 11 About Emerson Network Power Emerson Network Power, a business of Emerson (NYSE:EMR), is the world’s leading provider of critical infrastructure technologies and life cycle services for information and communications technology systems. With an expansive portfolio of intelligent, rapidly deployable hardware and software solutions for power, thermal and infrastructure management, Emerson Network Power enables efficient, highly-available networks. Learn more at: www.emersonnetworkpower.com About Emerson Emerson (NYSE: EMR), based in St. Louis, Missouri (USA), is a global leader in bringing technology and engineering together to provide innovative solutions for customers in industrial, commercial, and consumer markets around the world. The company is comprised of five business segments: Process Management, Industrial Automation, Network Power, Climate Technologies, and Commercial & Residential Solutions. Sales in fiscal 2015 were $22.3 billion. For more information, visit: www.emerson.com Official Wechat Official Weibo Legal statement: While every precaution has been taken to ensure accuracy and completeness herein, Emerson assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice. Emerson Network Power Co., Ltd. Pre-sales hotline: After-sales hotline: Address: Block B2 Nanshan Park No.1001 Xueyuan Road Nanshan Dist. Shenzhen, 518055 China China Telephone: 86-755-86010808 Postcode: 518055 400-887-6526 400-887-6510 www.emersonnetwork.com.cn Emerson Network Power, ASCO, the Emerson Network Power logo and ASCO logo are trademarks and service marks of Emerson Electric Co. ©2016 Emerson Electric Co. E-X621****-0516 13