17607book.fm Page 10 Monday, September 10, 2012 12:51 PM QO™ and QOU Miniature Circuit Breakers QO™ Miniature Circuit Breakers Class 730, 731, 733 / Refer to Catalog 0730CT9801 QO™ miniature circuit breakers are plug-on products for use in QO load centers, NQOD panelboards, NQOD OEM interiors or Speed-D™ switchboard distribution panels. Bolt-on QOB circuit breakers are for use in NQOD panelboards or interiors.a The QO exclusive Qwik-Open™ mechanism, with a trip reaction within 1/60th of a second, is standard on all 1P 15 A and 20 A QO circuit breakers. Plug-On Circuit Breakers QO-QOB Ring Terminal (20% $ Price 2P—120/240 Vac 2P—240 Vac c 3P—240 Vac Adder)—Factory Installed Only 1P—120/240 Vac Amperes Rating b QOT 1P Tandem 1 Space Required DE3 CIRCUIT BREAKERS QO 1P 1 Space Required QO 2P 2 Spaces Required QO2200 2P 200 A 4 Spaces Required Common Trip Cat. No. $ Price Cat. No. 10 k AIR 10 A QO110 QO210 15 A QO115 de QO215d 20 A QO120de QO220d 25 A QO125d QO225d 30 A QO130d QO230d 35 A QO135d QO235d 40 A QO140d QO240d 45 A QO145d QO245d 50 A QO150d QO250d 60 A QO160d QO260d 70 A QO170d QO270d 80 A — QO280d 90 A — QO290d 100 A — QO2100d 110 A — QO2110d 125 A — QO2125d 150 A — QO2150dfk 175 A — QO2175dfk 200 A — QO2200dfk Molded Case Switch 60 A max.–240 Vac — Molded Case Switch 100 A max.–240 Vac — Common Trip $ Price Cat. No. $ Price Common Trip Cat. No. — QO215H QO220H QO225H QO230H — QO240H — QO250H QO260H QO270H QO280H QO290H QO2100H — — — — — QO200 QO2000i QO310 QO315d QO320d QO325d QO330d QO335d QO340d QO345d QO350d QO360d QO370d QO380d QO390d QO3100d — — — — — QO300 QO3000i 22 k AIRd 15 A 20 A 25 A 30 A 40 A 50 A QO115VHe QO120VHe QO125VH QO130VH — — QO215VHg QO220VHg QO225VHg QO230VHg QO240VHg QO250VHg — — — — — — QO315VHg QO320VHg QO325VHg QO330VHg QO340VHg QO350VHg 60 A 70 A 80 A 90 A 100 A 110 A 125 A 150 A 175 A 200 A — — — — — — — — — — QO260VHg QO270VHg QO280VHg QO290VHg QO2100VHgh QO2110VHgh QO2125VHgh QO2150VHfgk QO2175VHfgk QO2200VHfgk — — — — — — — — — — QO360VHg QO370VHg QO380VHg QO390VHg QO3100VHg — — — — — 42 k AIRd 40 A 45 A 50 A — — — QOH240i QOH245i QOH250i — — — — — — 60 A 70 A 80 A 90 A 100 A 110 A 125 A — — — — — — — QOH260i QOH270 QOH280 QOH290 QOH2100 QOH2110i QOH2125 — — — — — — — — — — — — — — $ Price DE3-10 15 A Poles Suffix 10–30 A 35–60 A 35–50 A 70–110 A 60–100 A 1, 2, 3 1,2 3 2 3 5237 Ampere Rating 10–30 A 10–30 A 35–70 A 10–30 A 10–30 A 35–70 A 80–125 A 150–200 A 10–30 A 35–70 A 80–125 A 110–150 A 15–20 A Wire Size (AWG/kcmil) 14–8 Al/Cu (2) 14–10 Cu 8–2 Al/Cu 14–8 Al/Cu (2) 14–10 Cu 8–2 Al/Cu 4–2/0 Al/Cu 4–300 Al/Cu 14–8 Al/Cu, (2) 14-10 Cu 8–2 Al/Cu 4–2/0 Al/Cu 4–300 Al/Cu 12–8 Al 14–8 Cu 15–30 A 40, 50, 60 A 10–60 A 12–8 Al 14–8 Cu 12–4 Al 14–6 Cu 12–2 Al 14–2 Cu 5238 5273 Wire Sizesb Circuit Breaker Type QO 1P QO 2P QO 3P QOB-VH QOT QO-AFI, QO-GFI & QO-EPD QO-PL Replacement Tandem Circuit Breakers 65 k AIRd QO 3P 3 Spaces Required Ampere Rating QH115e QH215 — QH315d 20 A QH120e QH220 — QH320 25 A QH125i QH225i — QH325i 30 A QH130 QH230 — QH330 a See Section 1 for load centers, and Section 5 for panelboards and interiors. o o b 10–30 A circuit breakers are suitable for use with 60 C or 75 C conductors. 35–125 A circuit breakers are suitable for use with 75oC conductors. c CSA/UL Listed 5 k AIR on corner grounded Delta systems. d CSA/UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers. e CSA/UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. f Requires four spaces (1 AWG–300 kcmil Al/Cu.) Suitable for switching 120 Vac fluorescent lighting loads. g CSA/UL Listed for use ahead of QO, QO-GFI, QO-EPD, QO-AFI, QOT,QOCAFI, and QO-PL 10 k AIR circuit breakers to permit their application at 22 kA fault level. h 100 A maximum branch mounted opposite. i Order only. Contact your local Field Office. j Includes two circuit breakers (one QO2030 and one QO3020) and handle tie QOTHT. k Not suitable for use in 3Ø panels. Use only in 1Ø panel rated 150 A or greater. Interrupting Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-2 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-12 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-54 For Use in Old Style Non-Class CTL QO Load Centers—10 k AIR Ampere Ratingb Cat. No.d $ Price 1P—120/240 Vac—1 Space Required 15 &A 15 A QO1515 15 A & 20 A QO1520 20 A & 20 A QO2020 20 A & 30 A QO2030 30 A & 20 A QO3020 Two 1P Individual Trip—120/240 Vac—2 Spaces Required Order Two QO1515 or QO2020 circuit 15 A & 15 A breakers and handle tie QOTHT for 15 A & 20 A common switching of center two poles. 20 A & 20 A — — 20 A & 30 A QO20303020j 30 A & 20 A — — 06/12 17607book.fm Page 12 Monday, September 10, 2012 12:51 PM QO™ and QOU Miniature Circuit Breakers QO™ Circuit Breaker Accessories Class 1130 / Refer to Catalog 0730CT9801 Accessories for Use with QO™ and QOB Miniature Circuit Breakers DE3 CIRCUIT BREAKERS Handle Attachments Description Converts any two adjacent 120/240 Vac 1P QO circuit breakers to independent trip 2P Handle Tie: Converts any two adjacent 120/240 Vac 1P side-by-side QOT circuit breakers to independent trip 2P Handle tie and lock-off for three 1P QO, QOB circuit breakers Clamp for holding QO 1P handle in ON or OFF position Handle Clamp: Clamp for holding QO or Q1 1P, 2P or 3P circuit breaker handles in ON or OFF position For padlocking 1P QO circuit breaker in ON or OFF position Loose attachment Fixed attachment For padlocking 1P side-by-side QOT circuit breaker in ON or OFF position Handle Padlock Attachment: for Padlocking in ON or OFF position For padlocking 2P and 3P QO-GFI, QO-EPD, and QO-EPE in either ON or OFF position, fixed attachment. For 2P and 3P QO and Q1 standard circuit breakers which require padlocking in either ON or OFF position. Loose attachment Fixed attachment For padlocking 1P QO circuit breaker in OFF position only, fixed attachment. For padlocking 2P and 3P QO circuit breakers in OFF position only, fixed attachment. Handle Padlock Attachment: for Padlocking in OFF position For padlocking 1P QO-GFI, QO-AFI, QO-CAFI, and QO-EPD circuit breakers in OFF position only, fixed attachment. For padlocking 2P and 3P QO-GFI, QO-EPD, and QO-EPE circuit breakers in OFF position only, fixed attachment. Sub-Feed Lugs 60 A 2P plug-on – 2 spaces required (6–2 Al/Cu) 125 A 2P plug-on – 2 spaces required (12–2/0 Al/Cu) 225 A 2P plug-on – 4 spaces required (4–300 Al/Cu) 125 A 3P plug-on – 3 spaces required (12–2/0 Al/Cu) For interlocking the handles of two 2P or one 2P and one 1P QO and Q1 circuit breakers mounted side-by-side so that Mechanical Interlock Attachment only one circuit breaker can be ON at a time (Not QOU) QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed circuit breakers in dual With Retaining Kit: power supply applications. Can be used with (2) 2Ps or (1) 2P and (1) 1P QO circuit breakers in QO816L100 load centers. a Not suitable for use in 3Ø panels. Use only in 1Ø panel rated 150 A or greater. QO1PL QO1PA Cat. No. QO1HT QOTHT QO3HT QO1LO HLO1 QOHPL QO1PA QOTHPA GFI2PA QO1HPL QO1PL QO1PAF QO2PAF QOGFI1PAF QOGFI2PAF QO60SL QO2125SL QO2225SLa QO3125SL QO2DTI QO2DTIM QO1PAF QO1LO QO1HT $ Price HLO1 QO2DTI QO2PAF QO1HPL QOGFI2PAF QOTHPA QOHPL Factory-Installed Accessories for Use with QO and QOB Miniature Circuit Breakers Factory-installed electrical accessories take up an additional pole space on QO™, QO-GFI, QO-EPD, QO-SWN and QOU circuit breakers. All AC electrical accessories shown below are rated for 50/60 Hz. Accessories are not available for QOB-VH (2P 150 A and 3P 110–150 A) circuit breakers or QO, QOU molded case switches. QO circuit breakers will accept only one accessory per circuit breaker. Undervoltage trip is not available on miniature circuit breakers. Factoryinstalled accessories are not available for QO-AFI or QO-CAFI Arc Fault Circuit Breakers or on QO2150, QO2175, or QO2200 circuit breakers. Factory-Installed Accessories Accessory Description Rated Voltage Trips the circuit breaker from a remote location by means of a trip AC/DC coil energized from a separate circuit. A 120 Vac shunt trip will AC operate at 55% or more of rated voltage. All other shunt trips will operate at 75% or more of rated voltage. Shunt Trip DE3-12 Application • For use with momentary or maintained push button. • Not available on QO-GFI, QO-EPD, QO-AFI, QOCAFI. • Shunt trip terminals accept (2) 14–12 AWG Cu. 12 24 120 208 240 Coil Cat. No. Burden Suffix 60 VA 168 VA 72 VA 228 VA 288 VA $ Price Accessory Adder -1042 -1021 Auxiliary Switches Description Monitors circuit breaker contact status and provides a remote signal indicating the circuit breaker contacts are OPEN or CLOSED. Application Contact Max. Comb. Voltage Max. Load Cat. No. Suffix 1A 1B AC 120 AC 120 5A 5A -1200 -1201 1A AC 120 5A -2100 $ Price Adder • Alarm Switches Auxiliary switch terminals accept (2) 14–12 AWG Cu leads. Used with control circuits and is actuated only when the circuit breaker has tripped. Standard construction includes a normallyopen contact. Application • Alarm switch terminals accept (2) 14–12 AWG Cu leads. 06/12 17607book.fm Page 54 Monday, September 10, 2012 12:51 PM Dimensions and Shipping Weights Miniature and Molded Case Circuit Breakers Figure 2 Figure 1 B E QO, QOB Figure 3 A G A G D C A G B E Circuit Breaker Catalogue No. Prefix B E Figure 4 QOB-VH 150 A QOB-VH 110–150 A QO-GFI, QO-PL QO-EPD A G E QO-PL QO-GFI QO-EPD D C E B QOU Low Ampere B QOU High Ampere DE3 CIRCUIT BREAKERS Figure 6 Figure 8 Figure 7 A G A G A G A a b c d e f F Figure 10 Figure 9 QOU High Ampere Figure 11 A A B E B E Multi 9™ C60 B E B E B E QOU, QYU Low Ampere D C D C Figure 14 QB, QD, QG, QJ Figure 12 Figure 15 A A Figure 16 A C60 A D C B B B B Figure 18 FIL, KIL E 1.34 2 2 1.50 3.00a 2.31 2.91 2.25 ... 3 3 2.25 3.00a 2.31 2.91 2.25 ... 2.09 2 2 3.0 5.72 2.53 4.90 3.78 ... 2.85 3 3 4.50 5.72 2.53 4.90 3.78 ... 4.35 1 4 0.75 4.12b 2.31 2.91 2.25 ... 0.59 2 5 1.50 4.12b 2.31 2.91 2.25 ... 1.34 3 5 2.25 4.12b 2.31 2.91 2.25 ... 2.09 1 6 0.75 4.05c 2.38 2.98 2.25 5.00p 0.62 2 7 1.50 4.05c 2.38 2.98 2.25 5.00p 1.37 3 8 2.25 4.05d 2.38 2.98 2.25 5.00f 2.12 1 9 0.75 4.45 2.37 2.96 2.25 6.78 ... 2 10 1.50 4.45 2.37 2.96 2.25 6.78 ... 3 11 2.25 4.45 2.37 2.96 2.25 6.78 ... 1 13 0.71 3.19 1.73 2.76 1.77 — — 2 14 1.42 3.19 1.73 2.76 1.77 — — 3 15 2.13 3.19 1.73 2.76 1.77 — — 4 16 2.84 3.19 1.73 2.76 1.77 — — Dimensions—Inches A B C D E F G H 2 22 6.47 3.00 3.02 3.93 g 4.25 ... ... 3 23 6.47 4.50 3.02 3.93 g 4.25 1.50 0.75 1 21 6.00 1.50 3.16 4.13 0.44 5.13 1.50 ... 2 22 6.00 3.00 3.16 4.13 0.44 5.13 ... ... 3 23 6.00 4.50 3.16 4.13 0.44 5.13 1.50 0.75 23 8.00 4.50 3.66 4.75 0.44 7.13 1.50 0.75 23 11.00 6.00 4.06 5.84 0.88 9.25 2.00 1.00 g Dimensions E are 1.59 in at ON end and 0.63 in at OFF end. Approx. Shipping Weight (Lbs.) Frame Size Approx. Shipping Weight (Lbs.) Figure 20 FAL, FHL 1P 2 KIL 9 A FAL, FHL 2P 3 LAL, LHL 15 FAL, FHL 3P 5 LIL LXIL 25 FIL 8 Q4L 15 QB, QD, QG, QJ 4 B E All weights are for 3P circuit breakers unless otherwise noted. Figure 23 Figure 22 B G 0.59 2&3 h Figure 21 G ... A B B F 2.25 Figure 19 A B E 2.91 Q4L, LAL, LHL 2 & 3 Frame Size A D 2.31 0.75 Shipping Weightsh E Figure 17 C 3.00a 1 35–70 A is 3.12 in; 80–100 A 2-pole and 70–100 A 3-pole are 3.50 in. QO-PL is 4.55 in. 80–100 A 1-pole and 80–125 A 2-pole are 4.45 in. 70–100 A 4.45 in. 80–100 A 1-pole and 80–125 A 2-pole are 6.78 in. 70–100 A is 6.78 in. FAL, FHL Figure 13 B 1 Circuit Breaker No. Fig. Catalogue No. Poles No. Prefix B E Figure 11 A QB, QD, QG, QJ, Q4, FA, FI, KI, LA, LH Circuit Breakers B F Figure 10 Dimensions—Inches No. Fig. Poles No. QO, QOB Figure 5 A G QO™, QOU, Multi 9™ Circuit Breakers B E B G HH D C C/L C/L A F A F A F E E E Figure 24 B G D C E A F E DE3-54 06/12