61.3
61
61
Operator Interface
Panel Meters
Product Overview
Product Selection Guide
61
61
Description
E5 Panel Meters
Eclipse Series Panel Meters
Page 247
Page 247
Number of digits
5
4
Display technology
7-segment LED
7-segment LED
Display character height
8 mm
14 mm
Panel cut-out size
1/32 DIN (25 x 50 mm)
1/8 DIN (45 x 92 mm)
Available outputs
None
Dual relay, analog, RS-485
Available inputs
0–10V/2–10V/0–20 mA/4–20 mA
DC volt, AC volt, DC amp, AC amp, 5A AC,
Temperature (J, K, T, PT100 RTD), 4–20 mA/0–10V/1–5V
Front panel protection
IP65
NEMA 4X
61
Connection method
Screw terminal
Depluggable screw terminals
Scaling
Programmable end points, linear interpolation
Programmable end points, linear interpolation
61
Input power options
10–30 Vdc
9–30 Vdc or 85–264 Vac
Update time
500 ms
400 ms
Automatic min/max capture
Yes
Yes
Input for display-hold
Yes
—
61
61
61
61
61
61
61
For our complete product offering, see Volume 7—Motor Controls, Logic and Connectivity, CA08100008E.
61
61
61
61
61
61
61
61
61
61
61
61
61
61
61
61
61
246
Volume 9—OEM Product Guide CA08100011E—February 2011 www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
61.3
Operator Interface
Panel Meters
Features
Digital Panel Meters
61
E5-324-E digital panel meters
●
Galvanic isolation with protection against incorrect polarity
●
Automatic min/max value detection
●
Freely programmable characteristic curve end points
●
Input range:
●
Single current measuring input (0/4–20 mA)
●
Single voltage measuring input (0/2–10V)
61
61
61
Eclipse Series digital panel meters
●
Four full digits
●
1/8 DIN size
●
Red, LED display
●
Scalable display
●
Flashing alarms
●
Min/max data hold
●
Optional analog, relay and RS-485 outputs
●
Type 4X
61
61
61
61
61
Catalog Number Selection
61
Digital Panel Meters
61
Eclipse Series
61
5770 X – 4 X X
61
Power Supply
0 = DC (9–30 Vdc)
1 = AC (85–265 Vac)
Output Option Input Option
0 = DC volt
1 = AC volt TRMS
2 = DC amp
3 = AC amp TRMS
4 = 5A AC TRMS
5 = Process (4–20 mA, 0–10V, 1–5V)
6 = Temperature (J, K, T, PT100 RTD)
61
0 = No option
1 = Dual relay
2 = Analog output (4–20 mA and 0–10V)
3 = Dual relay, analog output (4–20 mA and 0–10V)
4 = RS-485 communications
5 = Dual relay, RS-485
6 = Analog, RS-485 (4–20 mA and 0–10V)
7 = Dual relay, analog, RS-485 (4–20 mA and 0–10V)
61
61
61
Product Selection
E5-324-E0402
61
E5-324-E0402
61
Description
Catalog Number
LED digital panel meter, 24 x 48 mm
E5-324-E0402
61
61
Eclipse Series
61
Eclipse Series
Description
Catalog Number
Digital ammeter—5A AC, 85–264 Vac power
57701440
Digital ammeter—5A AC, 85–264 Vac power, 2 relay outputs
57701441
Digital process meter—4–20 mA/0–10V, 85–264 Vac power
57701450
Digital process meter—4–20 mA/0–10V, 85–264 Vac power, 2 relay outputs
57701451
Digital process meter—4–20 mA/0–10V, 85–264 Vac power, 2 relay outputs and analog retransmission
57701453
Digital temperature meter, 85–264 Vac power
57701460
Digital temperature meter, 85–264 Vac power, 2 relay outputs
57701461
61
61
61
61
61
Note
Output options 0, 2, 4 are not available for models -41X and -43X.
61
61
61
Volume 9—OEM Product Guide CA08100011E—February 2011 www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
247
Index
A
AC, 1-2
against, 2
alarms, 2
ammeter, 2
amp, 1-2
Analog, 2
analog, 1-2
and, 1-2
are, 2
at, 1-2
Automatic, 1-2
Available, 1
available, 2
C
CA, 1-2
call, 1-2
capture, 1
Catalog, 2
character, 1
characteristic, 2
com, 1-2
communications, 2
complete, 1
Connection, 1
Connectivity, 1
Controls, 1
current, 2
curve, 2
cut, 1
D
data, 2
DC, 1-2
Delivery, 1-2
Depluggable, 1
Description, 1-2
detection, 2
Digital, 2
digital, 2
digits, 1-2
DIN, 1-2
Display, 1
display, 1-2
Dual, 1-2
Index
eaton, 1-2
Eclipse, 1-2
end, 1-2
incorrect, 2
Input, 1-2
input, 2
inputs, 1
Interface, 1-2
interpolation, 1
IP, 1
isolation, 2
F
K
Features, 2
February, 1-2
Flashing, 2
For, 1-2
for, 1-2
Four, 2
Freely, 2
Front, 1
full, 2
KMParts, 1-2
E
L
LED, 1-2
linear, 1
Logic, 1
G
Galvanic, 2
Guide, 1-2
H
height, 1
hold, 1-2
I
Immediate, 1-2
M
mA, 1-2
max, 1-2
measuring, 2
meter, 2
Meters, 1-2
meters, 2
method, 1
Min, 2
min, 1-2
mm, 1-2
models, 2
Motor, 1
ms, 1
Index
N
NEMA, 1
No, 2
None, 1
not, 2
Note, 2
Number, 1-2
O
OEM, 1-2
of, 1
offering, 1
Operator, 1-2
Option, 2
option, 2
Optional, 2
options, 1-2
or, 1-2
our, 1
out, 1
Output, 2
output, 2
outputs, 1-2
Overview, 1
P
Page, 1
Panel, 1-2
panel, 1-2
points, 1-2
polarity, 2
Power, 2
power, 1-2
Process, 2
process, 2
Product, 1-2
product, 1
Programmable, 1
programmable, 2
protection, 1-2
PT, 1-2
R
range, 2
Red, 2
relay, 1-2
retransmission, 2
RS, 1-2
RTD, 1-2
S
Scalable, 2
Screw, 1
screw, 1
see, 1
segment, 1
Selection, 1-2
Series, 1-2
Single, 2
size, 1-2
Supply, 2
Support, 1-2
T
Tech, 1-2
technology, 1
Temperature, 1-2
temperature, 2
terminal, 1
terminalsScaling, 1
time, 1
TRMS, 2
Type, 2
Index
U
Update, 1
V
Vac, 1-2
value, 2
Vdc, 1-2
volt, 1-2
voltage, 2
Volume, 1-2
W
with, 2
www, 1-2
Y
Yes, 1
Download