c Installation Instructions Hi-Lo Pressure Regulator Valve Kits with Backhand Relief This manual provides instructions for Cascade Hi-Lo Pressure Regulator Kits for carton clamps. Pressure Regulator Kit 6845338 6845339 6845340 6845341 Voltage 12V 24V 36V 48V Cascade recommends using a low pressure tank line kit for a dedicated return connection to the truck tank. AC2477.eps Low Pressure Tank Line Kit Hi-Lo Valve Part No. 6845342 cascade W corporation For Technical Support . . . To Order Parts . . . Call: 1-800-227-2233 Fax: 1-888-329-8207 Call: 1-888-227-2233 Fax: 1-888-329-0234 Internet: www.cascorp.com Internet: www.cascorp.com Write: Cascade Corporation, PO Box 20187, Portland, OR 97294 Write: Cascade Corporation, 2501 Sheridan Ave., Springfield, OH 45505 Installation 1 1 Disconnect the cable from the negative battery terminal. 2 Locate and install the Hi-Lo Valve on the truck cowl or under the floorboard using a 5/16 in. (8 mm) capscrew. If mounting on the cowl, watch for clearance when the mast is tilted back. The Valve has adjustment screws that need easy access for final adjustment. Disconnect cable from negative battery terminal 3 Install a return to tank line to the Hi-Lo Valve T port to connect with the truck tank line. Cascade Low Pressure Return Line Adapter Kits are listed below. GA0436.eps NOTE: If the Hi-Lo Valve is being installed with an AntiSpike Valve, a dual line adapter kit with be needed. The circuit schematic for installing with the Anti-Spike Valve is shown on the next page. Tank Hose ID Single Line Adapter Kit Part No. Dual Line Adapter Kit Part No. .75 in. (19 mm) 1.00 in. (25 mm) 1.25 in. (31 mm) 1.50 in. (38 mm) 214062 211745 214066 6037507 6049380 6049381 6049382 6049383 4 2 Install tee fittings Install Hi-Lo Valve Assembly 5 Install hoses to CL and OP ports 6 4 Install No. 8 tee fittings to the CL and OP ports on the Hi-Lo Valve. 5 Install two No. 8 hoses from the truck clamp auxiliary valve CLAMP and OPEN ports to the tee fittings on the Hi-Lo Valve CL and OP ports. 3 6 Install a No. 8 hose from the Hi-Lo Valve CL port tee fitting to the supply circuit for the attachment CLAMP port. 7 Install a No. 8 hose from the Hi-Lo Valve OP port tee fitting Install hose to attachment clamp port Install return to tank line to the supply circuit for the attachment CLAMP port. 7 6 Install open circuit hose AC2474.eps 8 Install the solenoid cable assembly to the solenoid terminals (included in Harness Kit 6846463). 7 Attachment Valve 8 CL Install solenoid cable assembly OP 4 5 OP 4 CL T Clamp Control Valve AC2475.eps Truck Hydraulic Pump Truck Relief Valve AC2472.eps 2 Truck Tank 3 Hi-Lo Valve Installed with Anti-Spike Valve Kit 6027353 SS CL SS OP Attachment Valve Anti-Spiking Valve SS SS CL CL IN TANK OUT OP CL T Sideshift Control Valve Clamp Control Valve Truck Relief Truck Pump Clamp Relief Adjustment Return to Tank Fitting Truck Tank AC2473.eps To set the relief cartridges, use a pressure gauge or clamp force indicator. Refer to your clamp force indicator guide. NOTE: If using a pressure gauge for cartridge adjusting, install a pressure gauge in the attachment valve test port. IMPORTANT: Relief cartridges are preset to 1000 psi. Relief pressure for each cartridges must be adjusted for your application. ClampLow Relief 1 Set the LOW clamp relief pressure. Loosen jam nut on the relief cartridge. Adjust the relief cartridge (3/16 in. Allen Wrench) inward (CW) to raise pressure or outward (CCW) to lower the pressure. 2 Clamp a light load and check the pressure. required. Tighten jam nut. Readjust as 3 Set the High clamp relief pressure. Loosen jam nut on the relief cartridge. Adjust the relief cartridge (3/16 in. Allen Wrench) inward (CW) to raise pressure or outward (CCW) to lower the pressure 4 Clamp a heavy load and check the pressure. required. Tighten jam nut. Readjust as Backhand Relief Adjustment 1 Loosen jam nut on the backhand relief cartridge. Adjust the relief cartridge (3/16 in. Allen Wrench) inward (CCW) to raise pressure or outward (CW) to lower the pressure. AC2478.eps ClampHigh Relief Backhand Relief 2 Open the arms with the back of one arm against a fixed object. Adjust the Backhand relief cartridge outward (CW) until the desired force is reached. Tighten the jam nut. 3 Hi-Lo Pressure Regulator Valve Kits with Backhand Relief 39 28 4 1 5 7 6 AC2476.eps 28 REF QTY 1 2 3 4 5 6 7 8 9 © Cascade Corporation 2013 1 3 1 1 1 1 1 1 1 2 3 1 PART NO. 6845338 6845339 6845340 6845341 6843107 6845337 6816255 6811566 6811553 6041432 6058521 6014287 6018032 6018036 6018038 602580 601250 601377 6051814 6041329 DESCRIPTION Hi-Lo Valve Kit – 12V Hi-Lo Valve Kit – 24V Hi-Lo Valve Kit – 36V Hi-Lo Valve Kit – 48V Hi-Lo Valve – 12V Hi-Lo Valve – 24V Hi-Lo Valve – 36V Hi-Lo Valve – 48V Valve Body Relief Valve Solenoid Cartridge Solenoid Coil – 12V Solenoid Coil – 24V Solenoid Coil – 36V Solenoid Coil – 48V Fitting, 8 Fitting, 8-8 Fitting, 8-8 Seal Kit Seal Kit 11-2013 Part Number 6845342