Three Phase Vacuum Contactors RP133 MODEL RP 133-2332-00 Weighing less than 30 pounds, this small contactor (11.8 x 10.5 x 5.5) is designed to meet the requirements of todays modern equipment. The size reduction is accomplished by utilizing three new Jennings vacuum interrupters that were developed for this specific purpose. The vacuum interrupter, a hermetic enclosure in which the contacts operate, is the key component of this three phase vacuum contactor. The contact-to-contact gap required to interrupt the circuit is short, thus permitting ultra reliable operation. The special contact materials used are rated for use up to 1.5 kV, 450 amperes load life and 4500 amperes fault current. The contactor, which use vacuum as the dielectric and interrupting medium, is performing better in many applications than the conventional air magnetic or oil immersed types that have been in general use. The contactor is rugged, requires minimal maintenance, is smaller and lighter than other types, and is environmentally safe and extremely durable. Because of their reliability and durability, vacuum contactors are becoming the switching device of choice in motor controllers that operate production and processing equipment, mining and construction equipment, earth movers or carriers, power shovels, rock crushers and conveyors. Designed to withstand the frequent switching required to control furnaces and large air conditioning motors, the RP133-2332-00 Contactor is commonly used to protect power transformers and DC power supplies, and also to switch capacitor banks for voltage regulation and power factor correction as a means of reducing operating cost. Load life of the RP133-2332-00 Contactor is typically one million operations at rated load current. Maintenance is minimized as the main contacts are sealed to eliminate contamination. It operates at an ambient temperature range of 40° to +85°C. RP133 Vacuum Interrupter used in RP133-2332-00 contactor. Jennings Technology Company 970 Mc Laughlin Avenue, San Jose CA 95122 Tel: (408) 292-4025 Fax: (408) 286-1789 Web: http://www.jenningstech.com ©Jennings Technology Company. All rights reserved. Three Phase Vacuum Contactors RP133 continued ELECTRICAL SPECIFICATIONS VOLTAGE RATINGS Maximum 3 Ø line voltage 600 V and 1.5 kV* Dielectrics 50/60/400 Hz, 60 sec. withstand line-to-ground 6.5kV RMS line-to-line 6.5kV RMS across open contacts 6.5kV RMS B.I.L. - 1.2 X 50, µsec impulse line-to-ground 20 kV peak line-to-line 20 kV peak across open contacts 20 kV peak CURRENT RATINGS (See Specifications for Complete Electrical Ratings) Continuous current 450 A RMS Load switching current 450 A RMS Capacitors - 750 KVAR @ 1.5 kV Motors - 750 HP @ 1.1 kV Making current Random make 100 times @ 1.5 kV with 3 sec. backup: 4.5 kA RMS Random make 10 times @ 1.5 kV with current limiting fuse: 28 kA pk Random make 100 times @ 1,5 kV with 3 sec. backup: 6 kA RMS Chop current @ 30 A switching with 1000 Ω surge impedance circuit 1.5 A max. Electrical Life @ rated switching current 106 close/open operations INTERRUPT CURRENT 4500A RMS @1.5 kV ACTUATOR Control Voltage 115 VAC +10% - 15% 50-60 Hz 110 VDC +10% - 20% Control Current Pull-in Amps 7.1 Hold-in Amps 0.9 AUXILIARY CONTACTS Configuration 2 NC, 3 NO, SPST double break, 10 A resistive @ 600 VAC *3300 VOLTS AVAILABLE ON SPECIAL ORDER. MECHANICAL SPECIFICATIONS Weight Release Time from control switch off to separation of main contacts Mounting 30 lbs. maximum 16 msec maximum Operates any position Jennings Technology Company 970 Mc Laughlin Avenue, San Jose CA 95122 Tel: (408) 292-4025 Fax: (408) 286-1789 Web: http://www.jenningstech.com ©Jennings Technology Company. All rights reserved. Three Phase Vacuum Contactors RP151B MODEL RP151B A small, lightweight 3 phase, normally open, 200 amp vacuum contactor for use in equipment which requires a high speed interrupt time. It is useful as an overload interrupter to 2000 amps RMS interrupting capacity. Special erosion resistant contacts offer long life without adjustment or contact maintenance at rated current of 200 amps. Typical test results indicate a minimum electrical load life of 250,000 operations. NOTE: Hardened version available. ACTUATOR SPECIFICATIONS GENERAL SPECIFICATIONS Rated Voltage 50/60/400 Hz Rated Continuous Current Maximum Interrupting Capability Current 600 Volts RMS 200 A RMS 2000 A RMS Interrupt Auxiliary Contacts Weight <2 cycles DPDT 115/230 VAC/8A 15 lbs Model No. RP151134541X44R20 RP151B4541X46R20 RP151B4541X47R20 Actuator Voltage 26.5 VIDC 100 VDC 115 VACR 50/60/400 Hz Pull-in Current (Amps) Hold Current (Amps) 4.0 1.5 1.5 0.40 0.05 0.05 Jennings Technology Company 970 Mc Laughlin Avenue, San Jose CA 95122 Tel: (408) 292-4025 Fax: (408) 286-1789 Web: http://www.jenningstech.com ©Jennings Technology Company. All rights reserved. Three Phase Vacuum Contactors RP173 MODEL RP 173-2310-00 Weighing less than 67 pounds, this small contactor (18X18x 8) is designed to meet the requirements of todays modern equipment. This small size is accomplished by utilizing three Jennings vacuum interrupters that were developed for this specific purpose. The vacuum interrupeter, a hermetic enclosure in which the contacts operate, is the key component of this three phase vacuum contactor. The contact-to contact gap required to interrupt the circuit is short, thus permitting ultra reliable operation. The special long life, low chop contact materials used are rated for use up to 7.2 kV @ 450/600 amperes. See Specifications for electrical load life. The contactor, which uses vacuum as the dielectric and interrupting medium, performs better in applications than the conventional air magnetic or oil immersed types that have been in general use. The contactor is rugged, requires minimal maintenance, is smaller and lighter than other types, and is environmentally safe and extremely durable. Because of their reliability and durability, vacuum contactors are becoming the switching device of choice in motor controllers that operate production and processing equipment, mining, petroleum and construction equipment, earthmovers and conveyors, power shovels and all types of industrial loads. Designed to withstand the frequent switching required to control furnaces and large motors, the RP 173-2310-00 Contactor is commonly used in industrial applications to switch power transformers and capacitor banks for voltage regulation and power factor correction as a means of reducing operating cost. Load life of the RP 173-2310-00 Contactor is typically one million operations at rated load current. Maintenance is minimized as the main contacts are sealed to eliminate contamination. It operates at an ambient temperature range of 40° to +85° C. Jennings Technology Company 970 Mc Laughlin Avenue, San Jose CA 95122 Tel: (408) 292-4025 Fax: (408) 286-1789 Web: http://www.jenningstech.com ©Jennings Technology Company. All rights reserved. Three Phase Vacuum Contactors RP173 continued ELECTRICAL SPECIFICATIONS VOLTAGE RATINGS 3 Ø line voltage 1.5, 2.5, 5.0 and 7.2 kV Dielectrics 50/60/400 Hz, 60 sec. withstand line-to-ground 30 kV RMS line-to-line 30 kV RMS across open contacts 30 kV RMS B.I.L. 1.2 X 50 µsec impulse line-to-ground 60 kV peak line-to-line 60 kV peak CURRENT RATINGS (See Specifications for Complete Electrical Ratings) Continuous current 450 A / 600 A RMS Load switching current 450 A RMS Capacitors - 2000 KVAR @ 4.16 kV* Grounded Neutral Motors - 5000 HP @ 7.2 kV Transformer - 5000 KVA @ 7.2 kV Making Current Random make 100 times @ 7.2 kV with 3 sec. backup: 4.5 kA RMS Random make 10 times @ 7.2 kV with current limiting fuse: 55 kA pk Random make 100 times @ 5.0 kV with 3 sec. backup: 6 kA RMS Chop current @ 30 A switching with 1000 Ω surge impedance circuit 1.5 A max. Electrical Life@ rated switching current 106 close/open operations INTERRUPT CURRENT 6000A RMS @ 5.0 kV ACTUATOR Control Voltage** 115 VAC +10% - 15% 50-60 Hz 110 VDC +10% - 20% Control Current Pull-in Amps 3.3 Hold-in Amps 0.5 AUXILIARY CONTACTS Configuration 2 NC, 3 NO, SPST double break, 10 A resistive @ 600 VAC *7.2 kV CAPACITIVE RATING AVAILABLE ON SPECIAL ORDER **For actuate voltage of 230 VAC or 220 VDC order Model No. RP173-2311-00 MECHANICAL SPECIFICATIONS Weight Release Time from control switch off to separation of main contacts Mounting 67 lbs. maximum 100 msec maximum Operates any position Jennings Technology Company 970 Mc Laughlin Avenue, San Jose CA 95122 Tel: (408) 292-4025 Fax: (408) 286-1789 Web: http://www.jenningstech.com ©Jennings Technology Company. All rights reserved.